omega.com e-mail: info@omega.com For latest product manuals: omegamanual.info L V800 SERIES Capacitance Point Level Sensors Shop online at U ser ’ s Guide.
Servicing Nor th America: U.S.A.: One Omega Drive, P.O. Box 4047 ISO 9001 Certified Stamford, CT 06907-0047 TEL: (203) 359-1660 FAX: (203) 359-7700 e-mail: info@omega.com Canada: 976 Bergar Laval (Quebec) H7L 5A1, Canada TEL: (514) 856-6928 FAX: (514) 856-6886 e-mail: info@omega.
This manual contains the information necessary to ensure a safe and successful installation. Please read and comply with the section on page 9 of this manual pertaining to SAFETY . Doing so will ensure proper oper- ation of the equipment and the safety of all personnel.
PRE-INST ALLA TION CONSIDERA TIONS 3 Choosing a Location: (See Figure 2) 1) Material Flow - When selecting a location for the LV800, choose a point in the vessel where the probe will be out of the direct flow of incoming and outgoing material to prevent any mechanical damage that may be caused by the pres- sure of the flow.
4 MECHANICAL INST ALLA TION Standard, Food Grade and Stub Probe Mounting: (See Figures 3 & 4) 1) Select a mounting location in accordance with the Pre- Installation Recommendations. 2) If using a welded fitting, cut a hole into the side/top of the vessel corresponding to the mounting connection (1-1/4” NPT or 3/4” NPT).
5 Figure 5 Power Input: (See Figure5) The LV800 is designed to accept either 115VAC or 230VAC (factory set). Verify the intended voltage supply is compatible with the voltage configuration indicated on the electronics and the external nameplate. Connect power as shown in Figure 5.
6 Delay: A potentiometer is provided for setting the time delay between the time material is "sensed" (Yellow LED on) and the time the relay contact output changes (Red LED on). Units have a 1- turn potentiometer. A clockwise rotation will increase the delay from .
TROUBLESHOOTING MAINTENANCE PROBLEM: Sensor will not sense material CAUSE/SOLUTION: 1) Verify power is applied to the sensor. 2) Verify "Sense Adjust." Reposition adjustment clockwise therefore making the probe more sensitive to "difficult to sense" materials.
8 MECHANICALS Standard Probe Stub Probe DIMENSIONS ARE SHOWN IN INCHES WITH MILLIMETER EQUIVALENT IN BRACKETS.
SPECIFICA TIONS SAFETY Power: 115VAC ( ± 15%); 2.5VA; 50/60Hz / 230VAC ( ± 15%); 2.5VA; 50/60Hz Altitude: 6562 ft (2000 m) max Installation Category: II Pollution Degree: 4 (Reduced to 2 by enclosure) Suitable for indoor/outdoor use Ambient Op Temp: -40˚ F (-40˚ C) to +150˚ F (+65˚ C) * Internal Bin Temp: To +176˚ F (+80˚ C) w/alum.
W ARRANTY / DISCLAIMER OMEGA ENGINEERING, INC. warrants this unit to be free of defects in materials and workmanship for a period of 13 months fro m da te o f pur chas e. OMEGA ’ s W ARRANTY adds an additional one (1) month grace period to the normal one (1) year product warranty to cover handling and shipping time.
M-4168/0405 Where Do I Find Ever ything I Need for Pr ocess Measurement and Contr ol? OM EGA…Of Course! Shop online at omega.com TEMPERA TURE M U Thermocouple, RTD & Thermistor Probes, Connector.
An important point after buying a device Omega LV800 (or even before the purchase) is to read its user manual. We should do this for several simple reasons:
If you have not bought Omega LV800 yet, this is a good time to familiarize yourself with the basic data on the product. First of all view first pages of the manual, you can find above. You should find there the most important technical data Omega LV800 - thus you can check whether the hardware meets your expectations. When delving into next pages of the user manual, Omega LV800 you will learn all the available features of the product, as well as information on its operation. The information that you get Omega LV800 will certainly help you make a decision on the purchase.
If you already are a holder of Omega LV800, but have not read the manual yet, you should do it for the reasons described above. You will learn then if you properly used the available features, and whether you have not made any mistakes, which can shorten the lifetime Omega LV800.
However, one of the most important roles played by the user manual is to help in solving problems with Omega LV800. Almost always you will find there Troubleshooting, which are the most frequently occurring failures and malfunctions of the device Omega LV800 along with tips on how to solve them. Even if you fail to solve the problem, the manual will show you a further procedure – contact to the customer service center or the nearest service center