EN
Omega logo
Official user manual

Omega DPG3000

2 pages·1 MB·Marine Instruments·PDF·ENDEFRITNLJA
Omega DPG3000
Table of Contents 10 sections Where Do I Find Everything I Need for · MADE IN · Process Measurement and Control? · OMEGA…Of Course! Shop online at www.omega.com · … ShowHide
Page 1 of the Omega DPG3000 user manual — M-3449/0499
Page 1 · click to enlarge
Page 1

WARRANTY/ DISCLAIMER OMEGA ENGINEERING, INC. warrants this unit to be free of defects in materials and workmanship for a period of 13 months from date of purchase. OMEGA’s Warranty adds an additional one (1) month grace period to the normal one (1) year product warranty to cover handling and shipping time. This ensures that OMEGA’s customers receive maximum coverage on each product. If the unit malfunctions, it must be returned to the factory for evaluation. OMEGA’s Customer Service Department will issue an Authorized Return (AR) number immediately upon phone or written request. Upon examination by OMEGA, if the unit is found to be defective, it will be repaired or replaced at no charge. OMEGA’s WARRANTY does not apply to defects resulting from any action of the purchaser, including but not limited to mishandling, improper interfacing, operation outside of design limits, improper repair, or unautho- rized modification. This WARRANTY is VOID if the unit shows evidence of having been tampered with or shows evidence of having been damaged as a result of excessive corrosion; or current, heat, moisture or vibration; improper specification; misapplication; misuse or other operating conditions outside of OMEGA’s control. Components which wear are not warranted, including but not limited to contact points, fuses, and triacs. OMEGA is pleased to offer suggestions on the use of its various products. However, OMEGA neither assumes responsibility for any omissions or errors nor assumes liability for any damages that result from the use of its products in accordance with information provided by OMEGA, either verbal or written. OMEGA warrants only that the parts manufactured by it will be as specified and free of defects. OMEGA MAKES NO OTHER WARRANTIES OR REPRESENTATIONS OF ANY KIND WHATSOEVER, EXPRESS OR IMPLIED, EXCEPT THAT OF TITLE, AND ALL IMPLIED WARRANTIES INCLUDING ANY WARRANTY OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE ARE HEREBY DISCLAIMED. LIMITATION OF LIABILITY: The remedies of purchaser set forth herein are exclusive, and the total liability of OMEGA with respect to this order, whether based on contract, warranty, negligence, indemnification, strict liability or otherwise, shall not exceed the purchase price of the component upon which liability is based. In no event shall OMEGA be liable for consequential, incidental or special damages. CONDITIONS: Equipment sold by OMEGA is not intended to be used, nor shall it be used: (1) as a “Basic Component” under 10 CFR 21 (NRC), used in or with any nuclear installation or activity; or (2) in medical applications or used on humans. Should any Product(s) be used in or with any nuclear installation or activity, medical application, used on humans, or misused in any way, OMEGA assumes no responsibility as set forth in our basic WARRANTY/ DISCLAIMER language, and, additionally, purchaser will indemnify OMEGA and hold OMEGA harmless from any liability or damage whatsoever arising out of the use of the Product(s) in such a manner.

Where Do I Find Everything I Need for

MADE IN

Process Measurement and Control?

OMEGA…Of Course! Shop online at www.omega.com

Omega DPG3000 — MADE IN diagram (page 1)
Fig. 1

TEMPERATURE Thermocouple, RTD & Thermistor

DATA ACQUISITION Data Acquisition & Engineering

Probes, Connectors, Panels & Assemblies Wire: Thermocouple, RTD &

Software Communications-Based Acquisition

Omega DPG3000 — MADE IN diagram (page 1)
Fig. 2

Systems Plug-in Cards for Apple, IBM &

Thermistor Calibrators & Ice Point References Recorders, Controllers & Process

Compatibles Datalogging Systems Recorders, Printers & Plotters

Monitors Infrared Pyrometers

HEATERS Heating Cable Cartridge & Strip Heaters Immersion & Band Heaters Flexible Heaters Laboratory Heaters

PRESSURE, STRAIN AND FORCE Transducers & Strain Gages Load Cells & Pressure Gages Displacement Transducers Instrumentation & Accessories

Shop online at

FLOW/LEVEL Rotameters, Gas Mass Flowmeters &

ENVIRONMENTAL MONITORING AND CONTROL Metering & Control Instrumentation Refractometers Pumps & Tubing Air, Soil & Water Monitors Industrial Water & Wastewater

www.omega.com e-mail: [email protected]

RETURN REQUESTS/ INQUIRIES Direct all warranty and repair requests/inquiries to the OMEGA Customer Service Department. BEFORE RETURNING ANY PRODUCT(S) TO OMEGA, PURCHASER MUST OBTAIN AN AUTHORIZED RETURN (AR) NUMBER FROM OMEGA’S CUSTOMER SERVICE DEPARTMENT (IN ORDER TO AVOID PRO- CESSING DELAYS). The assigned AR number should then be marked on the outside of the return package and on any correspondence. The purchaser is responsible for shipping charges, freight, insur- ance and proper packaging to prevent breakage in transit.

Flow Computers Air Velocity Indicators Turbine/Paddlewheel Systems Totalizers & Batch Controllers

pH/CONDUCTIVITY pH Electrodes, Testers & Accessories Benchtop/Laboratory Meters Controllers, Calibrators, Simulators &

Treatment pH, Conductivity & Dissolved Oxygen

FOR WARRANTY RETURNS, please have the following information available BEFORE contacting OMEGA: 1. Purchase Order number under which the product was PURCHASED, 2. Model and serial number of the product under warranty, and 3. Repair instructions and/or specific problems relative to the product.

FOR NON-WARRANTY REPAIRS, consult OMEGA for current repair charges. Have the following information available BEFORE con- tacting OMEGA: 1. Purchase Order number to cover the COST of the repair, 2. Model and serial number of the product, and 3. Repair instructions and/or specific problems relative to the product.

Pumps Industrial pH & Conductivity

DPG3000 PRESSURE GAUGES

OMEGA’s policy is to make running changes, not model changes, whenever an improvement is possible. This affords our customers the latest in technology and engineering. OMEGA is a registered trademark of OMEGA ENGINEERING, INC. © Copyright 2004 OMEGA ENGINEERING, INC. All rights reserved. This document may not be copied, photocopied, reproduced, translated, or reduced to any electronic medium or machine-readable form, in whole or in part, without the prior written consent of OMEGA ENGINEERING, INC.

M-3449/0499

Instruments · Equipment

Page 2 of the Omega DPG3000 user manual — Earth or System Ground
Page 2 · click to enlarge
Page 2
Omega DPG3000 — Earth or System Ground diagram (page 2)
Fig. 3 · Earth or System Ground

DPG3000 Digital Pressure Gauge instructions All units are factory calibrated prior to shipment. 1) ZERO TRIMMING: Loosen the set screw retaining the front cover and rotate counter- clockwise to remove. You will now have access to the zero adjust potentiometer which is marked with a “Z”. An ideal zero is indicated by a reading of 000 with an intermittently flashing “-” sign. A jeweler screwdriver or an eyeglass screwdriver is a suitable instrument. Be careful NOT to touch the “S” pot to the right, as changing this adjustment will invalidate the factory calibration. 2) BATTERY REPLACEMENT: After removing the front cover as in 1), loosen the small set screw at the bottom of the Display Assembly and remove the Assembly from the Housing (be careful of the Sensor Leads). The batteries can now be pulled from the holders and replaced with P/N DPG-BAT-C or equivalent. 3) RE-CALIBRATION This procedure requires a known pressure source of at least +/-0.1% accuracy in order to fully utilize the accuracy potential of the DPG-3000. (If not available, gauge can be returned for re-calibration). 4) PROCEDURE: A) With 0 psig applied (port vented) adjust zero as per instructions in #1. B) Apply full-scale pressure to the pressure port and adjust the span (“S”) pot until display reads the correct pressure. C) Re-check zero and re-adjust the zero (“Z”) pot if required. D) Repeat steps B) and C) until no further adjustment is required.

5. 4/20 mA TRANSMITTER OPTION: (–A4 Option) When equipped with this option the gauge no longer operates from batteries

but instead is “Loop Powered”. The loop connection is made to a terminal strip located inside the housing. A voltage of between 9 and 32 VDC must be maintained at this connection (Red is positive “+” black is negative “-”) to insure proper operation. Completion of the earth or system ground (Green) is recommended for proper circuit protection. Power supply voltage must be sufficient to maintain a minimum of 9 VDC at the gauge terminals after “dropping” voltage across RL at full scale current (20mA). Example: If RL = 250 ohm then “drop” is 0.02 Amps X 250 ohm = 5 volts. Therefore power supply minimum is 5V + 9V = 14V. RE-CALIBRATION: Procedure is the same as in 3,except that there are 2 sets of

zero and span adjustments. The front panel controls affect the display and the rear controls (remove electronics as in Step 2) affect the 4/20 mA signal. NOTE:

DO NOT UNSCREW SENSOR FROM HOUSING, THIS WILL DAMAGE THE UNIT.

Omega DPG3000 — Earth or System Ground diagram (page 2)
Fig. 4 · Earth or System Ground

Earth or System Ground

Output

Ask about the Omega DPG3000

Owners and our team usually reply within a day — and your question helps the next person too.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
No questions yet about the Omega DPG3000

Be the first to ask — other owners or our team will answer.

Original document

Omega DPG3000 manual PDF

2 pages·1 MB·Marine Instruments·PDF
Click any page above to open it here
Page 1 / …
100%
Loading pages…