repair may not be possible. ■Before use, perform an advance check as described in this manual.
This instruction manual uses various pictographs for correct use of the product and to prevent danger to the user and other persons as well as property damage. These pictographs and their meanings are shown below.
This indicates contents for which the possibility of human death or severe injury in case of handling under disregard of this indication can be assumed.
This indicates contents for which the possibility of human injury or the possibility of material damage in case of handling under disregard of this indication can be assumed.

swallowed. 2. Do not store with a battery in the digital camera housed in this product. Storage with a battery inserted may lead to leakage of the battery liquid and fire. 3. The Case must be used in combination with the separately available Waterproof Port. Remember that the Case cannot be used without the Waterproof Port. 4. If leakage of water should occur with a camera installed in this product, quickly remove the battery from the camera. There is the possibility of ignition and explosion from generation of hydrogen gas. 5. This product is made of resin. There is the possibility that injuries may be caused when it becomes broken because of strong impact with a rock or other hard objects. Please handle with sufficient care. 6. The silica gel and the grease for silicone O-rings for this product are not edible.
1. Do not disassemble or modify this product. This may cause water leakage or trouble. In case of disassembly or modification by persons other than those appointed by OLYMPUS IMAGING CORP., the guarantee shall not apply. 2. Do not place this product at locations with abnormally high or abnormally low temperatures or at locations with extreme temperature changes. The product may deteriorate. 3. Opening and closing at locations with much sand, dust, or dirt may impair the waterproof characteristic and cause water leakage. This should be avoided. 4. This product has been designed and manufactured for use at a water depth within 40 m. Please note that diving to a depth in excess of 60 m may cause permanent deformation or damage to the Case and the camera inside the Case or may lead to water leakage. 5. Rough handling, such as jumping into the water with the case in your hand or in an outside pocket or throwing the case into the water, etc. could lead to water leakage. Please always take care when using the case. 6. If the camera contained in the case becomes wet because of water leakage, etc., immediately wipe off all moisture and check the camera is working correctly. 7. Before travelling by air, please make sure you remove the O-ring, otherwise the difference in air pressure may make it impossible to open the case. 8. To ensure safe and trouble-free handling and operation of the digital camera in this product, please read the camera’s instruction manual carefully. 9. When sealing this product, please take care to ensure no foreign matter such as sand, dirt or hair are on the O-ring or contact surfaces. 10. The digital camera’s built-in flash cannot be used when the Case is being used. To avoid damaging the Case or the digital camera, do not attempt to load the digital camera into the Case when the flash is extruded from the camera. 11. When using this Case, you cannot adjust the angle of the LCD monitor on the digital camera. Any attempt to forcefully close this Case when the angle of the LCD monitor angle has been modified could result in damage to the Case or the digital camera.

When water leakage occurs while this product is being used, repair of the camera housed in this product may become impossible. Please observe the following cautions for use.

Examples for foreign matter sticking to the O-ring
2. The O-ring is a consumption product. Please replace it at least once a year by new one. Also perform maintenance for every use. 3. Deterioration of the O-ring will progress according to the use conditions and the storage conditions. Immediately replace the O-ring by a new one if it is damaged, shows cracks, or has lost its elasticity. 4. At the time of O-ring maintenance, clean the inside of the O-ring groove and confirm the absence of dirt, dust, sand, and other foreign matter. 5. Apply the specified silicone O-ring grease to the O-ring. 6. The waterproof function is not effective when the O-ring is not installed correctly. When installing the O-ring, take care that it does not project from the groove and that it is not twisted. Also, when sealing the Case, close the lid after confirming that the O-ring has not come out of the groove. 7. This product is an airtight construction made of plastic (polycarbonate). When it is left for a long time in a car, on a boat, at the beach, or at other places reaching a high temperature, or when it is subjected for a long time to uneven external force, it may be deformed and the waterproof function may be lost. Pay sufficient attention to temperature control. Also do not place heavy objects onto the product during storage or transport, and avoid unreasonable storage. 8. When the O-ring contact surface is pressed strongly from the outside of the Case, or when the Case is twisted, the waterproof function may be lost. Take care not to exert excessive force. 9. Please be sure to perform the advance test and the final test each time before using the case. 10.If you should notice drops of water or other signs of water leakage while taking pictures, immediately stop the dive, remove any water from the camera and the product, test according to the item "Final check", and confirm whether leakage has occurred or not.
Hair Fibers Fibers

Chemicals which cannot be used Explanation
Volatile organic solvents, chemical detergents
Do not clean the Case with alcohol, gasoline, thinner or other volatile organic solvents or with chemical detergents etc. Pure water or lukewarm water is sufficient.
Do not use anticorrosion agents. The metal parts use stainless steel or brass, and washing with pure water is sufficient.
Do not use commercial defogging agents. Always use the specified desiccant silica gel.
Grease other than specified silicone grease
Use only the specified silicone grease for the silicone O-ring, as otherwise the O-ring surface may deteriorate and water leakage may be caused.
Do not use adhesive for repairs or other purposes. When repair is required, please contact a dealer or a service station of our company.
Anticorrosion agent · Commercial defogging agents · Adhesive


Check the contents of the package.
Check that all accessories are in the box. Contact your dealer if accessories should be missing or damaged.

Authorized distributors list/ Authorized service centres list
· Instruction manual · (this manual)

Palm grip ❈ Shutter lever Hand strap ring ❈ _ (Exposure correction) button ❈ Mode dial knob Accessory mount TTL cable cover Front lid ❈ Zoom dial Front cap ❈ (Information display)button ❈ button ❈ (Erase) button ❈ (Play) button Pickup finder
❈ Eyepiece shutter lever ❈ button ❈ (Live view) button ❈ Control dial knob ❈ button ❈ button ❈ /Cross-cursor button ❈ /Cross-cursor button ❈ button ❈ /Cross-cursor button ❈ (Metering)/Cross- cursor button LCD monitor window Rear lid Camera table O-ring (POL-E01B)
Hot shoe cable mount (with a cap) Loading guide rails Buckle open/close levers Camera table clamping lever Optional bracket mount Buckle hook LCD inner hood O-ring (POL-E01A) Silica gel Grease for silicone O-ring (White cap) O-ring remover Waterproof cap maintenance adapter Hand strap
digital camera. When the operation parts of the Case are operated, the corresponding functions of the digital camera will operate. For details of the functions, refer to the instruction manual for the digital camera.

Install the Waterproof Port.
To enable the Case to be used underwater, the separately available Waterproof Port for the camera lens must be installed on the Case. Align the Waterproof Port with the position where the camera lens will be when the camera is loaded in the Case. For more details on attaching the Waterproof Port to the Case, refer to the instruction
manual provided with the Waterproof Port Apply the provided O-ring grease to the O-ring section of the Waterproof Port and the
Waterproof Port mounting thread on the Case. Screw the Waterproof Port into the Case by turning it all the way clockwise.

Attach the hand strap to the Case.




: • Be sure to install the hand strap correctly as shown above.
Hand strap ring

Mastering basic Case operations.
Before loading the digital camera, be sure you are comfortable with basic Case operations.
Hold the Case firmly with both hands so that you can see the image you want to shoot through the pickup finder on the Case or on the LCD monitor.
: • Do not apply excessive force to the waterproof port.
When pressing the shutter lever, press it gently, so that there will be no movement of the camera.
The case is equipped with a mode dial knob that fits on the camera's mode dial and functions the same way. After inserting the digital camera into the case, make sure that the mode dial knob is operable before taking any image.
: • Make sure that the Case’s mode dial knob is properly positioned on
camera’s mode dial. Remember that the rotation range of the camera’s mode dial is limited. Do not turn the Case’s mode dial knob beyond the rotation range of the camera’s mode dial.
Right Wrong

The Case’s zoom dial can be used to control the digital camera’s zoom ring or its manual focus ring. Which operation is available depends on the lens being used.
Whether or not the Case’s zoom ring can control the camera’s zoom ring and focus ring depends on which lens is mounted on the digital camera. For details, refer to the instruction manual for the optional waterproof port.
Waterproof Port Applicable Lens Zoom Ring Focus Ring Note
14-45mm Controllable Not controllable Only autofocusing is
possible.
35mm Macro Not controllable Controllable*1 The lens’ focus ring can
be rotated by 360°.
PPO-E02 14-54mm 11-22mm Controllable Not controllable Only autofocusing is
possible.
Manual focusing is possible but the MF ring rotation range is limited to 180°.
PPO-E03 50mm Macro Not controllable Controllable*2
50mm Macro +EC14 Not controllable Not controllable Only autofocusing is
possible. PPO-E04 +PER-E02 7-14mm Controllable Not controllable Only autofocusing is
possible.
PPO-E04 8mm Fisheye Not controllable Controllable*3 The lens’ focus ring can
be rotated by 360°.
*1. The optional PPZR-E04 focusing gear is required. *2. The focus ring on the lens can be turned 360° by using the optional PPZR-E04. *3. The optional PPZR-E05 focusing gear is required.
Data as of April 2006.

Move the power switch lever of the Case to turn the camera ON and OFF.
: When the digital camera has not been operated for a certain period of time, the sleep mode (standby status) is engaged . The duration before the sleep mode is engaged can be set on the digital camera. To exit the sleep mode (and restore camera functions), press any button (such as the shutter button). For details, refer to the digital camera’s instruction manual.
To prevent extraneous light from getting on the viewfinder screen when shooting with the camera and viewfinder held away from your face, use the eyepiece shutter lever on the Case to close the eyepiece shutter.
: Before loading the digital camera in the case, confirm that the camera’s eyepiece shutter is closed. Set the eyepiece shutter lever on the Case to the “Open” position (the position in which the lever is turned fully counterclockwise) before sealing the Case. The camera’s eyepiece shutter lever cannot be controlled if the Case is sealed without aligning the eyepiece shutter lever on the Case with one on the camera.
Power switch lever · Open · Close


To perform TTL flash shooting in combination with the
separately available Electronic Flash Case, remove the TTL cable connector cap as described below.
1Remove the TTL cable connector cap from the Case.
2Connect the Electronic Flash Case’s underwater TTL cable to the TTL connector on the Case.
How to attach the TTL cable connector cap to the case
Make sure there is no foreign matter attached to the O-rings inside the cap and on the TTL cable connector. To secure the cap, gently turn it clockwise until it stops.

: • If the TTL cable connector cap is loose, water penetration may result. Be
sure to gently turn the cap until it stops to make sure it is firmly secured. Do not turn or tighten the TTL cable too hard. If it is too tight, it may be difficult to loosen and remove it.
❈For details on the TTL cable and hot shoe cable, refer to the instruction manual provided
with the Electronic Flash Case.
If the threaded sections of the TTL cable and TTL cable connector stick to each other, the cable may disconnect from the connector. To prevent this, apply O-ring silicon grease (provided with this case) to the threaded sections. For details, see the maintenance description on page E-32 of this manual.
Contact Olympus for support. CAUTION
: • If you cannot disconnect the TTL cable, do not use force to disconnect it.

To perform TTL flash shooting using the Case, connect the hot shoe cable provided with the Electronic Flash Case between the connector on the Case and the digital camera’s hot shoe.

Turn the hot shoe cable connector cap inside the case counterclockwise to remove it.
Insert the connector of the hot shoe cable into the case's connector and turn the connector screws all the way clockwise to connect them firmly.
Insert the hot shoe on the hot shoe cable into the hot shoe on the camera.
When not using the hot shoe cable, attach the hot shoe cable cap to the hot shoe cable connector inside the case and turn the cap all the way clockwise to attach it firmly.
of the hot shoe cable into the case’s connector. CAUTION
: • Be sure to remove the camera from the case when inserting the connector
The digital camera is loaded and clamped in the Case by means of the camera table located inside the front lid of the Case.

Turn the camera table clamping lever counterclockwise to unlock it.
To load the digital camera into the Case, insert the screw of the camera table into the tripod screw hole on the bottom of the digital camera and turn the screw clockwise to secure it. For details, refer to "Attaching the digital camera to the camera table" later in this manual.
Slide the camera table into the camera table base in the front lid of the Case.
Turn the camera table clamping lever all the way clockwise to clamp the camera table.
❈To remove the camera, reverse the above procedure.

This Case has been the subject of thorough quality control for the parts during the manufacturing process and thorough function inspections during the assembly. In addition, a water pressure test is performed with a water pressure tester for all products to confirm that the performance conforms to the specifications. However, depending on the carrying and storage conditions, the maintenance status, etc., the waterproof function may be damaged. Before diving, always perform the following advance test and the water leakage test after installation of the camera.
Check the waterproof parts of the Case as described below.
: • The most suitable method for checking water leakage is to immerse the
Case to the intended water depth. When this is difficult, water leakage also can be checked at a shallow depth with no water pressure. Do not feel that this is troublesome, but perform this test. • If the advance test should show water leakage with normal handling, stop using the Case and contact your dealer or an Olympus service station.

Check the digital camera.
Check the digital camera before loading it in the Case.
Underwater shooting can reduce battery life because the picture has to be checked on the LCD monitor before and after shooting. Make sure that you have sufficient remaining battery capacity before use.
should always a fresh fully charged battery before each dive.
Check that the image storage medium has enough room for the number of pictures you want to take.
If a strap or lens cap is attached to the digital camera, it must be removed before loading.
: • If the digital camera is loaded without removing the strap or lens cap, it may
get caught between the Case lids and cause water leakage. • When removing the strap and/or lens cap, handle the digital camera carefully. OLYMPUS IMAGING CORP. shall not be responsible for damage caused by improper handling.
Remove the eyecup from the digital camera.
The Case allows you compose your shots in the pickup viewfinder. To improve the view of the pickup viewfinder, remove the camera’s eyecup before loading it in the Case.
: Be sure to remove the eyecup before loading the digital camera. Otherwise, the rear lid of the Case cannot be closed tightly causing water leakage. CAUTION
If a filter is attached to the lens of the digital camera, remove the filter before loading the digital camera in the Case.
: The digital camera cannot be loaded in the Case while the filter is attached to the lens. Be sure to remove the filter before loading. CAUTION

Prepare the digital camera.
This product (PT-E02) is exclusively for use with the E-330 Digital Camera.
Refer to the digital camera’s instruction manual for details on how to make sure the camera is operating correctly.
Open the Case.
(1) Unlock the four buckles on the Case. Do this by

unlocking buckles that are diagonally opposite to each other. Unlock the first pair (either A or B in the illustration on the right), and then unlock the two remaining diagonally opposite buckles.
(2) To open a buckle, hook your finger on the lower
side of the tip of a buckle lever as shown on the right, and lift the buckle up gently.
(3) After unlocking the four
buckles, hold the rear lid of the Case firmly with both hands and open the buckles all the way to separate the rear lid from the front lid.

Attaching the zoom ring provided with the optional waterproof port on the lens
To control zooming (or to control manual focusing when the mounted lens is a 50 mm macro lens), attach the zoom gear, provided with the optional waterproof port, to the zoom ring on the lens. For details on attaching the zoom gear, refer to the optional waterproof port’s instruction manual.

The lock lever is used to lock the zoom gear.
: • Confirm that the zoom gear is locked firmly with the lock lever.
For details on attaching the zooming/focusing gear, refer to the zooming/focusing gear’s instruction manual.

Before loading the digital camera in the Case, remove the camera table inside the front lid of the Case and attached it to the digital camera.
(1) Attach the camera table to the tripod
seat on the bottom of the digital camera by means of the tripod screw hole on the digital camera.
(2) The camera table has fixed top-bottom
and front-rear orientations. Refer to the illustration on the right to ensure that you attach it with the correct orientation.
Front Top Bottom · Rear

Insert the digital camera in the Case.
Load the digital camera in the Case after checking the following:

(1) Pull out the zoom dial and mode dial on the Case (pulling out the mode dial also pulls up
the power switch lever) so that they do not get in the way while loading the digital camera.
Set the power switch lever and eyepiece shutter lever as shown below.
(2) Remove the TTL cable connector cap from the hot shoe connector on the top left
corner of the inner side of the front lid of the Case. Connect the hot shoe cable to the connector.
upside down. Be careful not to drop the Case. CAUTION
: • When screwing in the hot shoe connector clamping screw, place the Case

(3) Place the camera table with the attached digital
camera on the camera table base in the Case. Do not load the combination by force, but load it gently so that the digital camera does not interfere with parts inside the Case.
After loading the digital camera, connect the hot shoe cable to the camera’s hot shoe.
Once the digital camera is fully inserted, turn the lock lever on the camera table to lock it.
Gently push the Case’s mode dial down and confirm that the zoom dial can smoothly control zooming, the power switch lever can turn the digital camera ON/OFF, and that the mode dial can control the mode dial of the camera.
: • Read the Waterproof Port’s instruction manual carefully to ensure that you

Before sealing the Case, insert the accessory silica gel bag (for prevention of fogging) between the bottom right corner of the camera and the Case. Insert the bag with the shorter side facing inside.

Pay attention to the orientation.

: • Insert the silica gel bag as far as it will go at the specified location and with
Check the loading status.
Always perform the following final checks before sealing the Case.

Seal the Case.
(1) Gently align the rear lid with the front lid.
(Do this gently so that the O-rings do not slip out of the grooves.)

(2) Engage the buckles with the hooks (two

diagonally opposite buckles first, then the other two diagonally opposite buckles)
Hook one pair of diagonally opposite buckles, then hook the other pair.
: Seal the Case by pushing all four buckle lock/unlock levers down in the direction of the arrows. If one of the buckles is left open or unlocked, the Case will not be sealed properly and water leaks will occur.

Check the operation of the loaded camera.
After sealing the Case, check that the camera functions normally.

: • If the camera does not function properly, remove the camera and reload it,
starting from "Check the digital camera," on page E-16 of this manual. • After loading the camera in the Case, confirm that the Case’s mode dial can be rotated. If not, the Case’s mode dial may not be positioned properly on the camera’s mode dial. Set the mode dials properly.
After closing the case tightly, check the seal between the front and rear lids and the connection between the port and case to make sure the O-rings are not twisted, that they sit properly in the grooves, and that no foreign matter has been caught between the two parts.
cause entry of water, so that special attention is required. CAUTION
: • Hairs, fibers, and other narrow items are not very apparent, but they may

The final test after loading the camera is explained below. This is the only way to eliminate worry about possible entry of water! Always perform this test. It can be performed easily in a water tank or a bathtub. The required time is about five minutes.
Simple water immersion test Explanatory image Hints
As the Case is transparent, waterdrops entering into it can be confirmed easily.
1 Place the Case slowly into the water.
In case of trouble with the O-ring, three seconds are enough for water to enter. Are there air bubbles coming out between the lids? Please check carefully.
2 At first, immerse the Case for only three seconds.
Remove the Case from the water and check that no water has accumulated at the bottom of the Case. Is there any water trickling down?
3 Check that no water has entered into the Case.
Check carefully for air bubbles! Do not perform any operation yet, but just observe.
4 Next, immerse the Case for 30 seconds.
Remove the Case from the water and check that no water has accumulated at the bottom of the Case. Perform very careful confirmation.
5 Check that no water has entered.
Check carefully for air bubbles! Try operation of the buttons used frequently. Check carefully for air bubbles! If there is still no entry of water, everything is OK!
6 Next, check by immersing for three minutes.
This is very important! Has the silica gel become moist? Please check carefully! As the inside can be seen, the inspection for entry of water also can be made securely!
7 This is the final check. Has the silica gel become moist?
If there is no water leakage and everything is functioning correctly, you are ready to start shooting underwater.
Now everything is all right! Have a nice dive! Did you remember to attach the balance weight?
❈The case shown in the above photos is for compact cameras. However, this Case can
also be tested with the same method.

Attach the hand strap to the Case, pass your right hand through the hand strap and hold the Case body with the same hand.


Take pictures.
After shooting, confirm picture on the pickup finder or LCD monitor.
Pictures taken while using the Case can be checked on the pickup finder or LCD monitor. Use the camera’s live view function to check pictures on the LCD monitor.
Start shooting while monitoring the LCD monitor display.
Press the (Live view) button of the Case to display the picture you have just taken on the LCD monitor. At this time, the button of the Case can be used for various operations including picture composition and focusing.

Mode A The subject is displayed on the LCD monitor so you can compose your shot.
Mode B The button can be used to display the subject by magnifying it by 10 times. The magnified picture can facilitate confirmation and adjustment of focusing.
: • When using mode A, close the eyepiece shutter to ensure accurate

Gently press the shutter lever.
When pressing the shutter lever, hold the Case securely with both hands and operate the lever gently to prevent camera shake.
The E-330’s built-in flash cannot be used when the camera is loaded in the Case. When flash shooting is required, use the separately available Electronic Flash and Electronic Flash Case.
: When using the separately available Electronic Flash and Electronic Flash Case, a bracket is also required to combine the Electronic Flash Case with this Case.
Wipe off any waterdrop.
After underwater shooting, remove any drops of water from the case. Use pressurized air or a soft, lint-free cloth to carefully wipe away any moisture from the hinge between the front and rear lids, the shutter release lever, the handgrip and the buckles.
: • Water left between the front and rear lids or between the case and port can

Remove the digital camera.
Unlock the buckles on the Case as shown below and carefully open the rear lid. Then, pull out the zoom dial and mode dial, turn the camera table lock lever counterclockwise, and gently lift the camera out of the case using both hands. To remove the digital camera from the Case, simply reverse the procedure described in “Insert the digital camera in the Case” on page E-20 of this manual.

Unlock two buckles on opposite corners first, and then unlock the other two buckles.

Pull out the zoom dial and mode dial on the Case so that they do not get in the way when you are removing the camera. After pulling out the dials, gently remove the camera using both hands.
: • After opening the Case, always place it so that the O-ring surface is face

Wash the Case with pure water.
After use, seal the Case again after taking out the camera and wash it sufficiently in pure water as soon as possible. After use in sea water, it is effective to immerse it for a fixed time in pure water to remove any salt.
: • Water leakage may be caused when a high water pressure is applied
Dry the Case.
After washing with pure water, use a soft cloth without any salt on it and not causing any fibers to wipe off any waterdrop and dry the Case completely at a well ventilated location in the shade.
: • Do not use hot air from a hair drier or the like for drying and do not expose the
Case to direct sunlight, as this may accelerate deterioration and deformation of the Case and deterioration of the O-ring, leading to leakage of water. When wiping the Case, take care not to cause scratches.

Remove the O-ring.
Open the Case and remove the O-ring. Procedure Insert the O-ring remover into the gap between the O-ring and O-ring groove wall. Bring the tip of the inserted O-ring remover below the O-ring. (Be careful not to damage
the groove with the tip of the O-ring remover.) Lift the O-ring, pinch its with your fingertips and pull it out of the Case.

Remove any sand, dirt, etc.
After visually checking that dirt has been removed from the O-ring, checking for attached sand and other foreign matter, as well as for damage and cracks can be done by squeezing the entire circumference of the O-ring lightly with your fingertips.
Remove attached foreign matter from the O-ring groove with a clean cloth or a cotton swab. Also remove any sand or dirt attached to the any part of the Case that comes into contact with the O-ring.
: • When a mechanical pencil or a similar other sharp object is used to remove

Install the O-ring.
Confirm that no foreign matter is attached, apply a thin coat of the accessory grease to the O-ring, and fit the O-ring into the groove. At this time, confirm that the O-ring does not stick out from the groove.
Make sure that your fingers and the O- ring are free of dirt, and squeeze about 5 mm of lubricant onto a finger. (5 mm is the most appropriate amount.)
1 Apply the exclusive lubricant to each O- ring.
Surround the lubricant with three fingers and spread it over the ring. Be careful not to use excessive force as this may stretch the O-ring.
2 Spread the lubricant all over the O-ring.
Check that the O-ring is free of scratch or unevenness.
After spreading the lubricant, check visually and by touch that the O-ring is not scratched and that its surface is flat. If it is damaged in any way, replace it with a brand-new O-ring.
4 Apply lubricant on the O-ring contact surface.
Use the lubricant remaining on the fingers to clean and lubricate the case's contact surface.
: • Always perform maintenance of the waterproof function even when the
Replace consumable products.
gel, and the O-ring. These consumable products also can be purchased at an Olympus service station.

Maintenance of the threaded sections on the TTL cable and TTL cable connector
If the threaded sections used to connect the TTL cable to the TTL cable connector are not maintained properly, salt and other seawater residue may adhere the TTL cable and prevent it from being disconnected. After use in seawater, clean off any salt, sand, or other residue as soon as possible, then dry the equipment thoroughly. Clean the threaded sections with a cotton swab and apply a thin, uniform layer of O-ring silicon grease (provided with this case).
Clean and apply O-ring silicon grease to these sections.
After removing the TTL connector cap from the waterproof cap, be sure to clean and grease the O-ring. Use the waterproof cap maintenance adapter to remove the O-ring unit from the waterproof cap.
Waterproof cap Waterproof cap maintenance adapter
Insert the adapter by aligning its pin with the hole on the cap.
Turn the adapter counterclockwise to remove the O-ring unit.
After removing the O-ring attached to the O-ring unit, clean the O-ring groove and apply silicon grease to the O-ring. Then, re-attach the O-ring to the O-ring unit.
❈Reverse the removal procedure to re-attach the O-ring unit to the waterproof cap.
O-ring

Q&A on the use of the PT-E02
Q1: What digital cameras can be used? A1: The PT-E02 is only for use with the E-330 digital camera.
Q2: Is underwater shooting possible with the PT-E02 alone? A2: In addition to the Case, you need the separately available Waterproof Port matching
the lens you are using.
Q3: What precautions must be observed when loading the digital camera into the Case? A3: Pay special attention to the following items when loading the camera into the Case.
(1) Check that the camera’s remaining battery capacity is sufficient. (2) Check how many pictures can be stored on the image storage medium.
Please use a medium with enough space to store all the pictures you want to take. This minimizes the number of times the Case has to be opened and closed. (3) Check that the zooming and focusing gears are attached properly to the lens of the
digital camera. (4) When using an external flash, check that the hot shoe cable is connected to the digital
camera. (5) Remove the carrying strap and lens cap from the digital camera.
If the carrying strap and lens cap are not removed from the digital camera, they could catch between the two lids of the case and prevent it from closing properly. This could lead to water penetration. (6) Before closing the case, check that the O-rings sit correctly in the groove. (7) Make sure that the buckles used for connection of the case and port and TTL
connector cap are closed firmly. (8) Make sure that the O-rings and the case's contact surfaces are free of foreign matter
and dirt. (9) Place the silica gel bag in the case to avoid fogging. Only use Olympus silica gel.
Q4: What cautions must be observed when using and storing the Case? A4: Pay special attention to the following items.
(1) When the O-ring contact surface is pressed strongly from the outside of the Case, or
when the Case is twisted, the waterproof function may be impaired and water leakage may be caused. (2) When the Case is used, left or stored at the following locations, defective operation or
trouble may be caused. Always avoid such locations. (a) Places where the Case can reach high temperatures under direct sunlight or in a
car, places with extremely low temperatures, and places with extreme temperature variations (b) Places with open fire (c) Places with volatile substances (d) Places with vibrations (3) In case of the following handling with a camera loaded into the Case, trouble or
breakage may be caused for the Case and/or the loaded camera. Always avoid such handling. (a) Hitting other objects (b) Dropping

(c) Placing heavy objects on top of the Case (4) When the Case is not used for a long time, trouble from formation of mold etc. may be
caused. Before use, confirm the operation of all operation parts and perform the advance test and the final test.
Q5: What cautions must be observed when opening and closing the Case? A5: Pay special attention to the following items.
(1) Do not open and close the Case at locations with water spray or sand spray. (2) Wipe off all waterdrops from the gap between the front lid and the rear lid and around
projections and recesses such as the buckles. When this is not done, entry of waterdrops into the Case is to be feared at the time of opening and closing. (3) When opening the Case, take care that no water will drip from your hair or body into
the Case or onto the camera. (4) When the case is open, examine the O-rings and the O-ring contact surfaces on the
front lid for foreign matter such as hair, fiber, and grains of sand. Remove these if present. Also examine the O-rings used for connection of the case and port. (5) Do not touch the camera or the image storage with your hands to which sea water is
sticking. (6) If you should detect waterdrops or other signs of water leakage while shooting,
immediately end the dive, perform the water leakage test again, and confirm that there is no leakage. If the camera is wet, wipe off any moisture and check the operation.
Q6: How should the Case be handled after use? A6: After use, take out the camera as soon as possible and wash the Case with pure
water. In case of use in the ocean, it is effective to immerse the Case for a certain time in pure water to remove any salt. Operate the buttons and levers under water to turn the shafts and wash off any salt. After washing, use a dry cloth without any salt on it to wipe off any moisture and dry the Case in the shade. Do not use hot air from a hair drier or the like and do not dry the Case under direct sunlight. Exposure to high temperatures or direct sunlight may cause deformation, discoloration or breakage of the Case and deterioration of the O-ring. Wipe the inside of the Case with a soft cloth not causing any fibers. Remove the O-ring, wipe off any salt, sand, dust, etc., and also clean the O-ring groove and the O-ring contact surface in the same way and then dry them. When an object with a sharp tip is used to remove the O-ring from the groove, the O-ring may be damaged and water leakage may be caused. Always use the accessory pick for O-ring removal.
Q7: How can I check for water leakage? A7: For confirmation, perform the advance test and the final test after loading the camera.
The advance test with immersing the Case without the camera to the intended use depth to check for water leakage is the most accurate test, but when this is difficult, it is safer to perform this test even at a depth of 1 m or in a bathtub. The final test also can be performed in a bathtub or a bucket.
Q8: What are the causes for entry of water? A8: The main causes for the entry of water are shown below. Please check them most
carefully. (1) Forgetting to install the O-ring (2) The O-ring is partly or completely outside the groove. (3) Damage, deterioration, or deformation of the O-ring

(4) Sand, fibers, hair or other foreign matter on the O-ring (5) When foreign matter (sand, fiber, hair, etc.) is stuck to the O-ring grooves or O-ring
contact surfaces. (6) Catching of the strap, the bag of silica gel, etc. at the time of sealing the Case. (7) Throwing the Case from a boat into the water, jumping with the Case into the water, or
other sudden application of strong forces onto the Case. When entering the water, hand the Case over quietly or avoid impacts in other ways.
Q9: What are the important points for O-ring maintenance? A9: Please observe the following items.
(1) Never use alcohol, thinner, benzene or similar organic solvents or chemical detergents
to clean the O-ring. When such chemicals are used, it is to be feared that the O-ring will be damaged or that its deterioration will be accelerated. (2) Always use genuine Olympus Grease for Silicone O-Ring (white cap). Other grease
may not be suitable for the silicone O-rings on the Case. Using the wrong grease may result in deterioration of the Case’s surface finish and interfere with the waterproof capability. (3) In order to avoid deformation of the O-ring when the Case is not used for a long time,
remove the O-ring from the Case, apply a thin coat of the special grease, and store the O-ring in a clean plastic bag. For reuse, confirm that the O-ring is free of damage and cracks, that it has sufficient elasticity, that the surface is free of stickiness and other abnormalities, and use it after applying a thin coat of the special grease. Excessive application of grease does not improve the waterproof function or the permissible withstand pressure. However, it may facilitate attachment of sand, dirt, etc. A thin, uniform coat produces the best result. (4) When using an external flash, check that the hot shoe cable is connected to the digital
camera. (5) The O-ring is a consumable product. Replace it at least once a year. (6) Deterioration of the O-ring is accelerated by the use conditions and the storage
conditions. Replace the O-ring immediately by a new one if it shows signs of damage, cracking or loss of elasticity.
Q10: What are the important points for Case maintenance? A10: Please observe the following items.
(1) Never use the following chemicals for cleaning, corrosion protection, defogging, repair
Q11: Please tell me about repairs. A11: Please contact a service station of our company or your dealer, if repair should be
necessary. Do not try to repair, disassemble or modify the Case yourself. Repair, disassembly or modification by you or third parties not authorized by Olympus invalidates the guarantee.

Q12: What are the model numbers of the accessories for the PT-E02? A12: The following accessories are available:
(1) O-rings for the PT-E02 body (POL-E01A, POL-E01B): These are silicone rubber O-
rings that have to be installed in the PT-E02 body to make it waterproof. There are two types of O-rings. O-rings for other Case models cannot be used. (2) The following waterproof ports are available for use with the PT-E02 Choose the one
corresponding to the lens you are using.
Waterproof Port Applicable Lens Note
14-45mm Provided with an exclusive zooming gear.
35mm Macro The lens’s focus ring can be rotated 360° using the optional PPZR-E04.
PPO-E02 14-54mm 11-22mm Provided with an exclusive zooming gear.
PPO-E03 50mm Macro* Provided with an exclusive zooming gear. The MF ring rotation range is limited to 180°.
When using the EC-14 lens, attach between the waterproof port and Case.❈The MF ring rotation range is limited to 180°.
PPO-E04 +PER-E02 7-14mm Only autofocusing is possible.
PPO-E04 8mm Fisheye The lens’ focus ring can be rotated by 360° using the optional PPZR-E05.
* The focusing ring of the lens can be rotated by 360° using the optional PPZR-E04.
(3) Grease for silicon O-ring (PSOLG-1): Exclusive grease for maintenance of the silicon
due to condensation. ❈You can order in large computer shops and camera mass sale stores. ❈Please contact your dealer or a service station of our company when replacement is
required. Replacement will be made against payment.

Available models Olympus Digital Camera E-330
Pressure resistance Depth of up to 60 m
Main materials Main body: Transparent polycarbonate resin. Release lever/power switch dial/mode dial/control dial/zoom dial/camera table: Polycarbonate resin. Port mount/camera table mount/pickup viewfinder frame/optional bracket mount/zoom dial gear/TTL connector cap: Aluminum. Operation buttons/buckles/accessory mount cover: Nickel-plated brass. Body cap: ABS resin. O-rings: Silicone rubber. Inner LCD hood: NBR rubber.
Dimensions Width 214 mm x height 168 mm x thickness 154 mm
Weight 1860 g (LCD hood not included)
❈We reserve the right to change the external appearance and the specifications without






Caisson étanche
Pour l’appareil photo numérique E-330 PT-E02
Fr
Owners and our team usually reply within a day — and your question helps the next person too.