CX2 SERIES
Optics and performance outstanding in its class


The evolution of this bestselling microscope delivers new, cost-efficient improvements in both optics and system performance. Newly equipped with Olympus' leading-edge UIS2 optical system, it provides significantly enhanced image clarity in a variety of observation methods, from brightfield to reflected light fluorescence. For all inspection and training applications in the fields of biology and medicine, the CX41 sets the pace for its class in both basic and system performance.







The CX41 provides images of outstanding brightness and clarity in a variety of observation modes. As well as Olympus' renowned UIS2 optics infinity system, it employs the PLCN series of Plan Achromat objectives, which are made from carefully selected top quality glass and manufactured with the most rigorous precision. The result is a major improvement in image flatness, with the 10X and 40X objectives in particular providing images that are among the very best in this class of microscope. Transmitted light illumination is from a 6V, 30W high-intensity halogen light source.
40X 10X

PLCN40X PLCN10X





Simple phase contrast attachment / CX-PH1, 2, 3 For phase contrast observations at 10X, 40X and 100X.


Slide condenser / CX-SLC Brightfield condenser / CH3-CD These Abbe type condensers allow brightfield observations from 4X to 100X. Accurate centering is provided by the attachment lens (CX-AL) and the iris diaphragm, to exclude unnecessary light and obtain bright Koehler illumination right across the magnification range. These highly economical condensers enable phase contrast and darkfield observations by simply adding basic accessories.
Darkfield central stop / CH2-DS For darkfield observations from 4X to 40X. * Separate filter holder (CH2-FH) or attachment lens (CX-AL) required.

Low magnification adapter /CX-LA Use of the 2X low magnification objective allows macro observation.

Reflected light fluorescence attachment / CX-RFA-2 Users can choose between blue or green excitation and transmitted light observations. UIS2 optics provide bright fluorescence images, with no intermediate magnifications when changing from transmitted light to fluorescence observation. Standard PLCN objectives can be used without replacement.
Simple polarizing condenser / CH3-CDP With the optional plate adapter U-TAD, polarizing observations from 4X to 100X using a tint plate can be performed. A U-GAN analyzer is provided for gout inspection. Polarizing objectives from 4X to 100X are available. * Separate polarizer U-POT and analyzer U-ANT required.


Dry darkfield condenser / CX-DCD This dry-type darkfield condenser gives a superior darkfield effect without the need for immersion in oil. Suitable for use at 10X and 40X magnifications.



Move the specimen with just one finger Rubber grips are provided for the stage handles, allowing the specimen to be moved smoothly with just one finger. The slim body and conveniently positioned controls ensure that everything is within easy reach, so operators can maintain a natural posture.
Tilting binocular tube The tilting binocular tube lets each operator select the most suitable and comfortable eyepoint — a valuable contribution to reducing fatigue in extended observation sessions. High cost-efficiency type (U-CTBI) is also available.



U-CTBI
Inward-facing quintuple revolving nosepiece The quintuple revolving nosepiece enables a wide range of magnification observations and various combinations of objectives. Unrestricted access to the space in front of the objective allows specimens to be exchanged quickly and easily.
Rackless stage with enhanced operability To keep the work area clear, and to avoid interference with observation operations, the X-direction travel guide does not extend out from the side of the stage. The main and sub-scale displays are designed for easy read-out.


Phase-contrast condenser / CX-PCD The multi-purpose CX-PCD condenser allows observation of brightfield, phase- contrast and darkfield images without exchanging condensers. Phase-contrast observation from 10x to 100x and darkfield observation from 10x to 40x is allowed.

Torque adjustable focusing knob The torque of the coarse focusing knob can be adjusted, to suit different operators' needs and to make focusing smooth and easy while keeping the hands on the desk. A stage upper limit stopper is also provided.
Easy transportation and installation The CX41 is eminently portable, with convenient handgrips at the front and back of the frame and no inconvenient protrusion of the stage guide.


Anti-fungus treatment The treatment applied to the observation tubes, eyepieces and objectives, protects quality of optical parts even in high humidity regions.


Easy digital imaging A simple eyepiece adapter enables an Olympus digital camera to be attached to binocular tube U-CBI30-2 — an easy, practical and cost-efficient means of obtaining digital images.

Eyepoint adjuster / U-EPA2 Allows the eyepoint position to be raised by 30mm. Up to two eyepoint adjusters can be attached between the frame arm and observation tube.

Dual observation attachment / U-DO3 Enables dual, simultaneous observation of a single specimen from the same direction with equal magnification and brightness for both operators. A pointer can be used to indicate specific sections of the specimen to simplify the training process and enhance discussion.
Arrow pointer / U-APT Enables insertion of an LED arrow for display in a photomicrograph.



2x magnification changer / U-ECA Magnification is doubled by engaging the auxiliary 2X lens.
Trinocular tube / U-CTR30-2 Still digital (DP12) or video cameras can be attached for on-site/remote illustration of educational/discussion meetings.

Trinocular intermediate attachment / U-TRU A binocular tube on its own allows photomicrography. Combination with this intermediate attachment type trinocular tube makes it possible to attach photographic equipment and a video camera at the same time.
Drawing attachment / U-DA The drawing attachment projects an image of the pencil and drawing surface into the visual field.


CX41+DP12
U-DAL10X




* The length marked with an asterisk (*) may vary accoding to interpupillary distance. Distance for figure shown is 62mm.

Certified ISO 14001 by Environmentally-friendly product All optical components in CX41 microscope use lead-free eco-glass.
Design and production at the OLYMPUS CORPORATION Ina Plant conforms with
Specifications are subject to change without any obligation on the part of the manufacturer.