INSTALLATION / OPERATION MANUAL FSTB-A SERIES BREWERS OASIS CORPORATION 265 N. Hamilton Road P. O. Box 3150•Columbus, OH 43213- 0150 1-800-64-OASIS (1- 800- 646-2747) www.
CAUTION: READ INSTALLATION / OPERATION INSTRUCTIONS PRIOR TO INSTALLING AND OPERATING THE FRESHSTART BREWER A. INSPECTION Brewer comes complete with brew basket, detachable po wer cord and installation/operation man ual (car afe may be included, b ut is so ld separately).
A. ENERGIZE BREWER / HOT TANK HEAT UP 1. To power up brewer and start the hot tank, push the ON/OFF MAIN POWER switch, at rear of the brewer, to the ON position (See Figure 2). 2. Turn the front control panel on by pressin g the ON/OFF BREW CANCEL button.
OPERATION INSTRUCTIONS B. CANCELLING A BREW CYCLE To cancel a brew cycle that is in process, press the ON/OFF BREW CANCEL button located on the front control panel. When canceling a bre w cycle, water is shut off to the spray head, but the brew ba sket will continue to dra in until depleted.
SERVICE INSTRUCTIONS B. CLEANING THE SPRAYHEAD Over time mineral build up ma y d evelop around the (6) spray holes on the spray head which may lead to pot volume variances. Periodic inspection a n d cleaning of the spray head is recommende d. 1. Turn spray head counter clockwise a quarter turn until it stops (see figure 6).
D. SERVICING THE MECHANICAL FLOATS Resetting the Safety Float 1. Remove cover from cabinet. 2. Press down on the safety float re-set button (see figure 8). Float arm inspection 1. Remove float cap from top reservoir. 2. Float arms should move up and down freely and should not bind or catch (see figure 9).
G. THERMOSTAT REPLACEMENT (CONTINUED) Limiter Control (see figure 11) 1. Follow steps 1 and 2 from Primary Thermostat. 2. Remove tank feed and vent silicone tubing fr om reservoir bottom. 3. Remove upper reservoir by releasing the (3) clips. 4. Remove both wires from limiter thermostat.
PROBLEM RESOLUTION TROUBLE SHOOTING GUIDE Brew Cycle Will Not Start • Check that the power cord is properly plugged into the IEC receptacle located at the back of the brewer (see Figure 5). • Check that the power cord is plugged into a proper electrical outlet (see Service Instructions Section C).
An important point after buying a device Oasis Concepts FSTB-A60 (or even before the purchase) is to read its user manual. We should do this for several simple reasons:
If you have not bought Oasis Concepts FSTB-A60 yet, this is a good time to familiarize yourself with the basic data on the product. First of all view first pages of the manual, you can find above. You should find there the most important technical data Oasis Concepts FSTB-A60 - thus you can check whether the hardware meets your expectations. When delving into next pages of the user manual, Oasis Concepts FSTB-A60 you will learn all the available features of the product, as well as information on its operation. The information that you get Oasis Concepts FSTB-A60 will certainly help you make a decision on the purchase.
If you already are a holder of Oasis Concepts FSTB-A60, but have not read the manual yet, you should do it for the reasons described above. You will learn then if you properly used the available features, and whether you have not made any mistakes, which can shorten the lifetime Oasis Concepts FSTB-A60.
However, one of the most important roles played by the user manual is to help in solving problems with Oasis Concepts FSTB-A60. Almost always you will find there Troubleshooting, which are the most frequently occurring failures and malfunctions of the device Oasis Concepts FSTB-A60 along with tips on how to solve them. Even if you fail to solve the problem, the manual will show you a further procedure – contact to the customer service center or the nearest service center