© Copyright, 2003, all rights reserved • Securitron Magnalock Corp., 550 Vista Blvd., Sparks NV 89434, USA Tel: (775) 355-5625 • (800) MAGLOCK • Fax: (775) 355-5636 • Website: www.securitron.com An ASSA ABLOY Group company PN# 500-16900 Rev. A.
Rev. A.2. 10/03 SECTION 4.2 KEYPAD CHANGEABLE PROGRAMMING -----------------------------Page 12 This section explains how to set up easy code change from the keyp ad by employing a Program code which is relatively constant and a User code which is often changed for better security.
Rev. A.2. 10/03 SECTION 6.3 ANTI-TAMPER ALARM FUNCTION ---------------------------------Page 18 Someone entering 16 wrong digits while attemp ting to guess the code will activate the programmable relay.
Rev. A.2, 10/03 Page-1 SECURITRON MODEL DK-26 DIGITAL KEYPAD INSTALLATION & OPERATING INSTRUCTIONS 1. DESCRIPTION Securitron's DK-26 is a digital keypad system designed for medium/high security control of electric locks. It consists of two components: the keypad and the CPU board connected by a 16 ft.
Rev. A.2, 10/03 Page-2 FIG. 1: PHYSICAL INSTALLATION OF KEYPAD MOUNTING SURFACE (1) MOU NT SCREW TO ENGAGE SL OT AT TOP OF KEYPAD DRILL 1 /8" ( 3MM) H OL E (2) DRI LL 3/8" (10 M M ) H OL E F OR C ABLE (3) SE CURE B OT TO M WI TH SECOND SCRE W.
Rev. A.2, 10/03 Page-3 3. WIRING 3.1 POWER SELECTION The DK-26 operates on 12 to 24 volts AC or DC. Nearly all electric locks operate on voltage within this range, so t he power supply you would normally utilize to operate the electric lock will also operate the DK-26.
Rev. A.2, 10/03 Page-4 FIG. 2: OVERVIEW OF CPU BOARD SRC REX UCD HCD NCX CX NOX NC2 C2 NO2 NC1 C1 NO1 GRN YEL RED BLU WH T BLK GRY BRN BGE ORG PNK VIO AC IN F DC IN/OUT + PRGM HARD CODE CODE MICROPROCESSOR AUX.
Rev. A.2, 10/03 Page-5 Note installation of the MOV across the power wires to the lo ck. The MOV is the small black disk shaped component furnished loose with the DK-26.
Rev. A.2, 10/03 Page-6 reduce the switching life of the relay. The arc also creates electronic noise which could cause the microprocessor to malfunction. The MOV should be spliced into the lock power w ires as close to the lock as possible . Some DC electric locks have internal kickback protection including all Securitron Magnalocks .
Rev. A.2, 10/03 Page-7 FIG 5: DC LOCK - DC POWER WIRING NC1 C1 NO1 AC IN F DC IN /OUT + POWE R SUPP LY 12 OR 24 VDC DC FAIL SE CURE OR FAI L SAFE L OCK MOV IF FAIL SECURE IF FA IL S AFE NOTE: MOV NO T REQUI RE D IF SECURITRON MA GNALO CK IS USED + + DC POWER NEED NO T BE RE GULATED 3.
Rev. A.2, 10/03 Page-8 lock and if it’s fail secure, the switch will need to send power to the lock. Figure 6 shows how to add external contacts for non timed remote release of the lock for both lock types.
Rev. A.2, 10/03 Page-9 When using exit switches, the possibility must be considered that an electronic failure may occur to the DK-26 and a person will not be able to exit. If the DK-26 controls the only door exiting the area, additional steps should be taken to improve the reliability of exiting so as to avoid trapping someone.
Rev. A.2, 10/03 Page-10 FIG. 8: DOUBLE BREAK WIRING FOR FREE EGRESS (SPDT SWITCH) 4. PROGRAMMING The DK-26 has ten numbered keys and a bell key which is used for several functions. Each of these keys is read separately by the unit, so the DK-26 is a true 11 digit access device .
Rev. A.2, 10/03 Page-11 "traffic control" applications, as the longer t he code remains unchanged, the greater the risk that an unauthorized person will be able to learn it. The DK-26 makes it simple for you to program t he unit in this “fixed” way.
Rev. A.2, 10/03 Page-12 codes to be certain that the uni t will operate only on the single code you plan to enter. Follow the steps shown below. Press the “Prgm Code” button on the CPU board for one second. Confirm fast flashing yellow LED Enter 0-0 followed by the Bell key (or wait 5 seconds).
Rev. A.2, 10/03 Page-13 After you’ve completed your entries, test your user and progr am codes by entering them . The user code should open the door. The program code should cause the yellow LED to flash rapidly (program mode). Exit the program mode by hitting the Be ll key.
Rev. A.2, 10/03 Page-14 Enter program code, followed by the Bell Ke y, note rapid yellow flashing LED (program mode) Enter prefix 0-1 followed immediately by a new 2-7 digit User code End your entry w.
Rev. A.2, 10/03 Page-15 button in the CPU board. It is deliberately kept separate from all programming functions. Another use for it, however, is as a “masterkey” code. For example, consider a facility with multiple DK-26’s under the control of different departments.
Rev. A.2, 10/03 Page-16 To delete all User codes , there is a special prefix. Put t he unit into program mode (fast yellow flash) from the “Prgm Code” button or from the existing Program code and enter 8-8 . This special prefix will immediately del ete all User codes and you’ll i mmediately receive the two red flashes.
Rev. A.2, 10/03 Page-17 To return the red/green LED l ogic to factory set default , put the unit into program mode and enter 7-4 . 6. USE OF THE PROGRAMMABLE RELAY The DK-26 CPU board includes a second relay w hose 5 Amp, SPDT contacts are marked CX, NCX and NOX (see Figure 2).
Rev. A.2, 10/03 Page-18 6.3 ANTI-TAMPER ALARM FUNCTION A person attempting to guess the code and pressing 16 wrong digits will put the DK-26 into alarm . The keypad's beeper and green LED will operate for 30 seconds during which time the keypad will accept no input.
Rev. A.2, 10/03 Page-19 6.5 NIGHTLIGHT FUNCTION When this function is selected, the act of t ouching any key will operate the programmable relay for five seconds. This may be used to turn on a la mp directed at the Keypad at night so that the person using the Keypad can see to enter the code.
Rev. A.2, 10/03 Page-20 7.3 ALARM SYSTEM SHUNTING The DK-26's lock control relay is of the double pole, double throw type. Note that in all the other drawings in this manual, we show only one of the poles being used (C 1, NC1 and NO1).
Rev. A.2, 10/03 Page-21 Put the unit into program mode and enter 8-0 to assign this function to the HCD terminal or 8-1 to assign it to the UCD terminal .
Rev. A.2, 10/03 Page-22 MAGNACARE ® LIMITED LIFETIME WARRANTY SECURITRON MAGNALOCK CORPORATION wa rrants that it will replace at cu stomer’s request, at any time for any reason, products manufac tured and branded by SECURITRON.
Rev. A.2, 10/03 Page-i APPENDIX A: COMMAND SUMMARY WITH THE UNIT IN PROGRAM MODE (FAST YELLOW FLASH): 00 followed by 5-7 digits sets Program code 01 followed by 2-7 digits set first User code 02-follo.
Rev. A.2, 10/03 Page-ii APPENDIX B: TROUBLESHOOTING Note first that the DK-26 repl aces older Securitron keypads: the DK-20, DK-20+ and DK-25. The DK-26 keypad and CPU board are not compatible with any of the older units so make sure you have both a DK-26 keypad and DK-26 CPU board.
Rev. A.2, 10/03 Page-iii If PolySwitch #1 has tripped , visually inspect the four large diodes on the board to see if a loose wire has fallen on them to create a short circuit.
Rev. A.2, 10/03 Page-iv entry will be ignored. Finally note that if terminals SRC and UCD are connected, all User codes will be disabled. If terminals SRC and HCD are connected, the Hard code will be disabled.
Rev. A.2, 10/03 Page-v PROBLEM -- How to check the Keypad For reference, when each key is pressed, two terminals w ill measure zero volts with respect to the WHT (common) terminal.
An important point after buying a device Assa DK-26 (or even before the purchase) is to read its user manual. We should do this for several simple reasons:
If you have not bought Assa DK-26 yet, this is a good time to familiarize yourself with the basic data on the product. First of all view first pages of the manual, you can find above. You should find there the most important technical data Assa DK-26 - thus you can check whether the hardware meets your expectations. When delving into next pages of the user manual, Assa DK-26 you will learn all the available features of the product, as well as information on its operation. The information that you get Assa DK-26 will certainly help you make a decision on the purchase.
If you already are a holder of Assa DK-26, but have not read the manual yet, you should do it for the reasons described above. You will learn then if you properly used the available features, and whether you have not made any mistakes, which can shorten the lifetime Assa DK-26.
However, one of the most important roles played by the user manual is to help in solving problems with Assa DK-26. Almost always you will find there Troubleshooting, which are the most frequently occurring failures and malfunctions of the device Assa DK-26 along with tips on how to solve them. Even if you fail to solve the problem, the manual will show you a further procedure – contact to the customer service center or the nearest service center