Welcome to the Express5800/120Mf server Service Guide. This manual describes the maintenance work necessary for the Express5800/120Mf basic processing unit. Keep this guide at hand for quick reference at any time it may be required.
Read the section “Safety Indications” first, then proceed to “Notes On Using The Nec Express Server”.
Preface v

Follow the instructions given in this service guide for proper operation and safe use of the NEC Express5800. This guide describes server components with possible danger, hazards that may be caused by ignoring warnings, and preventive actions against such hazards. Server components with possible danger are indicated with a warning label placed on or around them. They are also described in this guide. In the user’s guide and on warning labels, “WARNING” or “CAUTION” is used to indicate a degree of danger. These terms are defined as follows:

This symbol indicates the presence of a hazard if the instruction is ignored. An image in the symbol illustrates the hazard type. (Attention)
This symbol indicates prohibited actions. An image in the symbol illustrates a particular prohibited action. (Prohibited Action)
This symbol indicates mandatory actions. An image in the symbol illustrates a mandatory action to avoid a particular hazard. (Mandatory Action) ( Example)
Symbol to draw attention Term indicating a degree of danger

Do not touch components in the NEC Express server while they are hot.
Components (e.g., especially hard disk drive) in the server are hot immediately after the power is turned off. Mount/dismount components only when they are cool. Symbol indicating a prohibited action (may not always be indicated)
vi Preface

Notes on Using the Server
This chapter includes useful information for proper and safe operation of the NEC Express server.
The warning label is attached to components with possible danger or their vicinity in the NEC Express server to inform the user that a hazardous situation may arise when operating the server. (Do not take off any label or soil it.)
If you find any label unattached, almost peeled off, or soiled, making the warning illegible, contact your sales agent.


1-2 Notes on Using the Server
This section provides notes on using the NEC Express server safely. Read this section carefully to ensure proper and safe use of the server. For symbols, see "SAFETY INDICATIONS" provided earlier.
Do not use the NEC Express server for services involving human lives or
equiring high reliability. r The NEC Express server is not intended to be used with or control facilities or devices concerning human lives, including medical devices, nuclear facilities and devices, aeronautics and space devices, transportation facilities and devices; and facilities and devices requiring high reliability. NEC assumes no liability for any accident resulting in personal injury, death, or property damage
f the NEC Express server has been used in the above conditions. i Do not use the NEC Express server if any smoke, odor, or noise is present. If smoke, odor, or noise is present, immediately turn off the POWER switch and disconnect the power plug from the outlet, then contact your sales agent.
sing the server in such conditions may cause a fire. U Keep needles or metal objects away from the NEC Express server. Do not insert needles or metal objects into ventilation holes in the NEC Express server or openings in the floppy disk or CD-ROM drive. Doing so
ay cause an electric shock. m
Do not let any form of liquid (water etc.) or foreign matter (e.g., pins or paper clips) enter the NEC Express server. Failure to follow this warning may cause an electric shock, a fire, or a failure of the server. When such things accidentally enter the server, immediately turn off the power and disconnect the power plug from the outlet. Do not disassemble the server. Contact your sales agent.

1-3 Notes on Using the Server

ollow this warning may cause an electric shock. f Do not connect the ground wire to a gas pipe. Never connect the ground wire to a gas pipe. Failure to follow this warning
Use a proper wall outlet. Use of an improper power source may cause a fire or a power leak. Do not install the NEC Express server where you need an extension cord. Use of a cord that does not meet the power specifications of the NEC Express
erver may heat up the cord and cause a fire. s Do not connect the power cord to an outlet that has an illegal number of
onnections. c
The electric current exceeding the rated flow overheats the outlet, which may
ause a fire. c Insert the power plug into the outlet as far as it goes. Heat generation resulting from a halfway inserted power plug (imperfect contact) may cause a fire. Heat will also be generated if condensation is formed on dusty blades of the halfway inserted plug, increasing the possibility
f fire. o

1-4 Notes on Using the Server
Use the authorized power cord only. Use only the power cord that comes with the NEC Express server. Use of an unauthorized power cord may cause a fire when the electric current exceeds the rated flow. Also, observe the following to prevent an electric shock or fire caused by a damaged cord.

1-5 Notes on Using the Server
CAUTION Never attempt to lift the NEC Express server only by yourself. The NEC Express server weighs up to 44 kg (depending on its hardware configuration). Carrying the server only by yourself may strain your back. Hold the server firmly by its bottom with another person to carry it. Do not hold the front door to lift the server. The front door may be disengaged from
he server, causing personal injury. t Do not install the NEC Express server in any place other than specified. Do not install the NEC Express server in the following places or any place other than specified in this User's Guide. Failure to follow this instruction may cause a fire. ! a dusty place ! a humid place such as near a boiler ! a place exposed to direct sunlight ! an unstable place Do not connect any interface cable with the power cord of the NEC Express
erver plugged to a power source. s
Make sure to power off the NEC Express server and unplug the power cord from a power outlet before installing/removing any optional internal device or connecting/disconnecting any interface cable to/from the server. If the NEC Express server is off-powered but its power cord is plugged to a power source, touching an internal device, cable, or connector may cause an electric shock
r a fire resulted from a short circuit. o Do not use any unauthorized interface cable. Use only interface cables provided by NEC and locate a proper device and connector before connecting a cable. Using an authorized cable or connecting a cable to an improper destination may cause a short circuit, resulting in a fire. Also, observe the following notes on using and connecting an interface cable. ! Do not use any damaged cable connector. ! Do not step on the cable. ! Do not place any object on the cable. ! Do not use the NEC Express server with loose cable connections.

1-6 Notes on Using the Server
Never attempt to disassemble, repair, or alter the NEC Express server on any occasion other than described in this User's Guide. Failure to follow this instruction may cause an electric shock or fire as well as malfunctions of the
erver. s Do not look into the CD-ROM drive A laser beam is used in the CD-ROM drive. Do not look into or insert a mirror into the drive while the drive is powered. If a laser beam is caught in your
yes, you may lose your eyesight (the laser beam is invisible). e Do not remove the lithium battery. The NEC Express server contains a lithium battery. Do not remove the battery. Placing the lithium close to a fire or in the water may cause an
xplosion. e
When the server does not operate appropriately due to the dead lithium battery, contact your sales agent. Do not disassemble the server to replace
r recharge the battery by yourself. o Disconnect the power plug before cleaning the NEC Express server. Make sure to power off the NEC Express server and disconnect the power plug from a power outlet before cleaning or installing/removing internal optional devices. Touching any internal device of the NEC Express server with its power cord connected to a power source may cause an electric shock
ven of the NEC Express server is off-powered. e
Disconnect the power plug from the outlet occasionally and clean the plug with a dry cloth. Heat will be generated if condensation is formed on a dusty plug,
hich may cause a fire. w

omponent. c Make sure to complete board installation. Always install a board firmly. An incompletely installed board may cause a

1-7 Notes on Using the Server
aught in the fan, resulting in injury. c Do not touch the NEC Express server when it thunders. Disconnect the power plug from the outlet when a thunderstorm is approaching. If it starts thundering before you disconnect the power plug, do not touch any part of the NEC Express server including the cables. Failure to
ollow this warning may cause a fire or an electric shock. f Keep any animal (pet) away from the NEC Express server.
Pet's discharges or fur may enter the NEC Express server and cause a fire or
lectric shock. e Do not place any object on top of the NEC Express server. The NEC Express server may fall and cause property damage to the
urroundings. s Do not leave the NEC Express server with its CD-ROM tray ejected. Dust may enter the server through openings and cause malfunctions of the
EC Express server. Any person may also bump it and get injured. N Take off the headset before connection. Make sure to take off the headset before plugging it to the headset jack. Failure to follow this instruction may hurt your ears. Make also sure to turn
own the volume before connection. d Do not use a cellular phone or pager around the NEC Express server. Turn off the cellular phone or pager. Radio interference may cause
alfunctions of the NEC Express server. m

1-8 Notes on Using the Server
Observe the following notes for successful operation of the NEC Express server. Use of the NEC Express server ignoring the notes will cause malfunctions or failures of the server.
! Install the NEC Express server in a place that meets requirements for successful operation.
For details, see Chapter 2, "Setting Up the Server."
! Do not delete the hard disk partition exclusively provided for maintenance of the NEC
Express server although it may appear on the OS.
! Make sure to power off the NEC Express server before connecting or disconnecting
cables between the server and peripheral devices.
! Verify that the access lamp on the NEC Express server is unlit before turning off the
server or ejecting the floppy disk.
! Do not turn on the server after plugging the power cord.
! Do not turn off the server until the "NEC" logo and the some characters appear on the
screen.
! When you have just turned off the NEC Express server, wait at least 30 seconds before
turning it back on.
! Turn off the power and unplug the power cord from the outlet before relocating the NEC
Express server.
! You may use a software command to eject the tray or a media from the CD-ROM drive or
an optional device, for example a DAT, installed in the 5.25-inch device bay, respectively. Make sure that the front door is open before ejecting the tray or media with a software command. Running the command when the front door is closed will cause the tray or media to hit against the front door, which may cause a hardware failure of the NEC Express server as well as a software error.
! Clean the NEC Express server on a regular basis. (See Chapter 5 for cleaning.)
Regular cleaning proactively prevents various failures of the server.
! Lightning may cause a momentary voltage drop. To prevent this problem, it is
recommended to use an uninterruptible power supply unit.
! Make sure to use optional devices supported by the NEC Express server. Some
non-supported devices may be physically installed/connected but cause failures of the server as well as a malfunction of the server.
! NEC recommends you use NEC's genuine products. Some third-party products claim
that they support the NEC Express server. However, repair of the server due to a failure or damage resulted from use of such third-party products will be charged.

1-9 Notes on Using the Server
The following must be observed when you transfer (or sell) the server or software provided with the server to a third party:
Make sure to provide the User’s Guide along with the server to a third party.
To transfer or sell any software application that comes with the NEC Express server to a third party, the following requirements must be satisfied:
! All provided software applications must be transferred and no backup copies must be
retained.
! Transfer requirements listed in "Requirements for Software Use" that comes with each
software application must be satisfied.
! Software applications that are not approved for transfer must be uninstalled before
transferring the NEC Express server.

1-10 Notes on Using the Server
! Dispose the server, hard disk drives, floppy disks, CD-ROMs, and optional boards as
required by the local regulations. Ask your local government for details.
! The NEC Express server contains some components that are only good for a limited
period of time and require replacement, such as fans, internal batteries, the internal CD-ROM drive, the floppy disk drive, and the mouse. For stable operation of the NEC Express server, NEC recommends you replace these components on a regular basis. Consult with your sales agent for replacement or the product lives.
WARNING Do not remove the lithium battery. The NEC Express server contains the lithium battery. Do not remove the battery. Placing the lithium or nickel cadmium battery close to a fire or in the water may cause an explosion. When the server does not operate appropriately due to the dead lithium battery, contact your sales agent. Do not disassemble the server to replace or recharge the battery by yourself.

Mother board

1-11 Notes on Using the Server
The longer you keep using the computer equipment, the more you become tired, which may cause disorders of your body. When you use a computer, observe the following to keep yourself from getting tired:
Good Working Posture You have good posture if the following are satisfied when you use a computer:

You have "good working posture" as described in the above when no part of your body is under excess strain, in other words when your muscles are most relaxed.
You have "bad posture" when you sit with your back hunched up or you operate a display unit with your face close to the screen. Bad working posture may cause eye strain or poor eyesight.
Adjustment of Display Unit Angles Most display units are designed for adjustment of the horizontal and vertical angles. This adjustment is important to prevent the screen from reflecting bright lights and to make the display contents easy to see. You will not be able to keep "good working posture" and you will feel more tired than you should if you operate a display unit without adjusting horizontal and vertical angles.

Adjustment of Screen Brightness and Contrast The display unit has brightness and contrast adjustment functions. The most suitable brightness and contrast depend on the individual and the working environment (well-lighted room or insufficient light). Adjust brightness and contrast so that the screen will be easy to see. An extremely bright or dark screen will give a bad effect to your eyes.

Adjustment of Keyboard Angle The keyboard provided with the NEC Express server is designed for adjustment of an angle. Adjust the keyboard angle at which the keyboard is easy to operate. The adjustment assists in reducing strain on your shoulders, arms, and fingers.
Cleaning of Equipment Clean equipment regularly. It is difficult to see the display contents on a dusty screen. Keeping equipment clean is also important for your sight.
Fatigue and Rest If you feel tired, you should stop working and do light exercises.

1-12 Notes on Using the Server
Before Asking for Repair, do the following when the NEC Express server appears to fail:
If the NEC Express server still appears to fail after you have taken the above actions, consult with your sales agent immediately. Take notes on lamp indications of the server and alarm indications on the display unit before consultation, which may provide a significant help to your sales agent.

Overview
This manual describes the maintenance method for NEC Express5800/120Mf basic processing unit. The explanation is for maintenance personnel who perform site adjustment, periodic inspection, and repair of NEC Express5800/120Mf basic processing unit. APPEARANCE
External dimensions (WDH, mm) 321×675×450

The table below lists the general specifications of the unit.

The power supply itself is capable between 100 to 240 VAC, however, the value at the left is used as a unit specification. Input current 5.3 A Apparent power 530 VA Power consumption
Power supply Single phase, 2-pole grounding Voltage 100 to 240 VAC±10%
Frequency 50±1 Hz or 60±1 Hz
Temperature 10 to 35oC Temperature and humidity Humidity 20 to 80%RH No condensation is allowed
POWER level 62.8 dB (operating) 60.9 dB (standby) Noise
2-2 Overview

Unit Configuration
120Mf Notes Processor Prestonia x 1-2 FSB 533MHz Package FC-mPGA2 CPU
Chipset Grand Champion-LE(REV A3.1) Max. 6GB (6 DIMMs) DIMM DDR266 SDRAM DIMM(Registered) ECC Yes Chipkill Yes Memory
2Way-Interleave 128/256/512MB/1GB DIMM *Online Spare memory
Intel Alliance Carrier Ultra320,10K/15Krpm, SCA2 Standard: 5 slots Optional: 5 slots added HDD cage
10 x 146GB+ U320 10Krpm 36GB/73GB/146GB
U320 15Krpm 36GB/73GB HDD
Max.
IDE I/F Ultra ATA100 x1ch For CD-ROM/DVD-ROM/DVD-RAM Non RAID Ultra320 SCSI x2ch SCSI I/F RAID iROC On-Board (AIC7899W)
Internal Option Max. 4 boards DiskArray
Ext. Option
LAN 10/100/1000BASE-T x2 On-Board, RemoteWakeUp
Video (VRAM) 640x480 ~ 1280x1024 (8MB) On Board, RageXL
FDD 3.5" (2mode) x1
CD-ROM Standard (x48/Half Height) Standard CDROM:
5.25” 3* (One for CDROM) *2 slots when rack conversion Device bay 3.5” Standard: 5(1”) + Option 5(1”) Max. 2HDD cages Ultra160 SCSI BP
Total 6slots (64bit/133MHz PCI-X x1, 64bit /100MHz PCI-X x2,
32bit/33MHz PCI x3) I/O slot
Hot Plug PCI No
Front Serial(DB9) x1*,USB x1
CRT x1, KB(PS/2) x1, Mouse(PS/2) x1,
USB x3,Serial(DB9) x2*, Parallel x1, 1000BASE-T x2, Ultra320 SCSI x1, ICMB x2(PCI slot option)
Power Supply(PS) Hotswap 2+1 x 350W (PFC) 1 AC cable/1 Power Supply Redundant PS Yes (option) Hotswapable Redundant FAN Yes (standard) Hotswapable Front Power, Sleep, Reset, Dump Switch Rear No
Front door Key Yes
Front Power/Sleep, System Status, HDD
LAN Link/Act. x2, UID LED
Rear LAN Link/Act. X2, LAN Speed x2, UID
Chassis design (WxDxH) Middle-Tower (321 x 675 x 450mm) Rack conversion(5U)

Please refer to the User’s Guide.
Please refer to the User’s Guide.
See next page.
3-2 Unit Configuration


3-3 Unit Configuration


3-4 Unit Configuration

Troubleshooting
If your NEC Express server does not operate as expected, read this chapter before assuming a failure.
On-screen error message Description Cause Action 0200 Failure Fixed Disk Hard disk failure 1. Incorrect setting in Setup 2. HDD failed 3. Motherboard failed
0210 Stuck Key Keyboard connection error
Keyboard is locked. Keyboard is locked. Release Keyboard lock
0220 Monitor type does not match CMOS - Run SETUP
The monitor type is not consistent with the CMOS data.
Incorrect monitor type setting
System RAM error.
DIMM failed 1. Replace DIMM 2. Replace Motherboard
0231 Shadow Ram Failed at offset
Shadow RAM error.
0232 Extended RAM Failed at address line
Extended RAM error.
0250 System battery is dead - Replace and run SETUP
The system battery is worn out.
NV-RAM battery Replace Motherboard
0251 System CMOS checksum bad - Default configuration used
The system CMOS checksum is incorrect.
NVRAM failed 1. Reset Setup parameters 2. Replace Motherboard
0252 Password checksum bad - Passwords cleared
The checksum of a password is inaccurate.
0260 System timer error A system timer error 0270 Real time clock error A real-time clock error RTC failed

On-screen error message Description Cause Action 0271 Check data and time setting
The real-time clock time setting is incorrect.
Unusual time setup of RTC
0280 Previous boot incomplete - Default configuration used
The last boot is imperfect.
Default value was set.
02B0 Diskette drive A error A floppy disk A error 02B1 Diskette drive B error A floppy disk B error FDD error Replace FDD
02B2 Incorrect Drive A type - run SETUP
Incorrect drive A type
Incorrect settings Reset Setup parameters
02B3 Incorrect Drive B type – run SETUP
Incorrect drive B type
02D0 System cache error - Cache disabled
A system cache error 1. CPU failed 2. Motherboard failed 1. CPU Exchange 2. Replace Motherboard 02D1 System Memory exceeds the CPU's caching limit.
The memory exceeds the limit of the cache of CPU.
Motherboard failed Replace Motherboard
02F4 EISA CMOS not write able
It cannot write in EISA CMOS. 02F5 DMA Test Failed DMA test error 02F6 Software NMI Failed Software NMI error 02F7 Fail-safe Timer NMI Failed
0611 IDE configuration changed
The composition error of IDE 0612 IDE configuration error-device disabled
The composition device error of IDE 0613 COM A configuration changed
The composition error of COM A 0614 COM A config. error- device disabled
The composition device error of COM A 0615 COM B configuration changed
The composition error of COM B 0616 COM B config. Error- device disabled
The composition device error of COM B 0617 Floppy configuration changed
The composition error of Floppy 0618 Floppy config. error - device disabled
The composition device error of Floppy 0619 Parallel port configuration changed
The composition error of Parallel port 061A Parallel port config. error - device disabled
The composition device error of Parallel port 0B00 Rebooted during BIOS boot at Post Code
The system re-started during BIOS boot
0B01 Rebooted during OS boot.
The system re-started during OS boot
4-2 Troubleshooting · Reset Setup parameters · Fail-safe Timer error

On-screen error message Description Cause Action 0B02 Rebooted during OS Runtime.
The system re-started during OS Running 0B1B PCI System Error on Bus/Device/Function
A PCI system error occurred on the bus, device, or function. 0B1C PCI Parity Error on Bus/Device/Function
A PCI parity error occurred on the bus, device, or function.
0B22 Processors are installed out of order.
Failure of a processor
Processor errors 1. Replace CPU 2. Replace Motherboard
0B28 Unsupported Processor detected on Processor 1
Unsupported processor mounted as processor 1.
0B29 Unsupported Processor detect on Processor 2
Unsupported processor mounted as processor 2.
0B30 Fan 1 Alarm occurred. 0B31 Fan 2 Alarm occurred. 0B32 Fan 3 Alarm occurred. 0B33 Fan 4 Alarm occurred. 0B34 Fan 5 Alarm occurred. 0B35 Fan 6 Alarm occurred.
Fan errors 1. Fan is blocked 2. Fan failed 3. Motherboard failed
0B50 CPU #1 with error taken off line
CPU #1 was degraded due to an error detected for CPU #1.
0B51 CPU #2 with error taken off line
CPU #2 was degraded due to an error detected for CPU #1.
0B5F Forced to use Processor with error
A CPU error was detected.
A memory error was detected. Memory #1 is degraded.
0B61 DIMM group #2 has been disabled
A memory error was detected. Memory #2 is degraded.
0B62 DIMM group #3 has been disabled
A memory error was detected. Memory #3 is degraded.
0B70 The error occurred during temperature sensor reading.
An error was detected in the course of thermal error detection.
0B71 System Temperature out of the range.
A thermal error was detected.
An error occurred while detecting the voltage.
Motherboard failed 1. Turn off AC 2. Check connection of internal cables
4-3 Troubleshooting

On-screen error message Description Cause Action 0B75 System Voltage out of the range.
A system voltage error was detected.
internal cables 3. Replace internal cables 4. Replace boards
An error was detected during fan sensor reading. 0B7C The error occurred during redundant power module confirmation.
0B78 The error occurred during fan sensor reading.
The error was detected while having constituted the redundant power supply.
0B7D The normal operation can't be guaranteed with use of only one PSU.
Basic power supply composition required for this equipment is not filled.
Power supply error Replace a power supply
0B80 BMC Memory Test Failed. 0B81 BMC Firmware Code Area CRC check failed. 0B82 BMC core hardware failure.
A BMC device (chip) failure
BMC failed 1. Turn off AC and re-start 2. Replace Motherboard
0B83 BMC IBF or OBF check failed.
Access to the BMC address failed.
0B8A BMC SEL area full. An opening is not in the capacity of SEL. 0B8B BMC progress check timeout.
BMC check was interrupted temporarily. 0B8C BMC command access failed.
BMC command access failed. 0B8D Could not redirect the console - BMC Busy -
Console redirection cannot be carried out (BMC Busy) 0B8E Could not redirect the console - BMC Error -
Console redirection cannot be carried out (BMC error) 0B8F Could not redirect the console - BMC Parameter Error -
Console redirection cannot be carried out (BMC Parameter error)
0B90 BMC Platform Information Area corrupted.
A BMC device (chip) failure
0B91 BMC update firmware corrupted.
0B92 Internal Use Area of BMC FRU corrupted
An error of the SROM that stores the chassis information
0B93 BMC SDR Repository empty.
A BMC device (chip) failure
4-4 Troubleshooting · BMC failed · BMC failed

On-screen error message Description Cause Action 0B94 IPMB signal lines do not respond.
An SMC (Sattelite Management Controller) error 0B95 BMC FRU device failure.
An error of the SROM that stores the chassis information 0B96 BMC SDR Repository failure.
The access error to FMEM sector in which SDR information was stored 0B97 BMC SEL device failure.
A BMC device (chip) failure
0B98 BMC RAM test error. BMC RAM error 0B99 BMC Fatal hardware error.
BMC failed 1. Turn off AC and re-start 2. Replace Motherboard
0B9A Management controller not responding
0B9B Private I2C bus not responding.
It-less answers from private I2 C bus 0B9C BMC internal exception
0B9D BMC A/D timeout error.
0B9E SDR repository corrupt.
The error of BMC or the data of SEL is destroyed. 0B9F SEL corrupt. The error of BMC or the data of SEL is destroyed.
0BB0 SMBIOS - SROM data read error.
Incorrect SROM data read 0BB1 SMBIOS - SROM data checksum bad.
Turn off AC and replace CPU#1
Incorrect SROM data checksum
0BC0 POST detected startup failure of 1st Processor.
Processor 1 error Turn off AC and replace CPU#1
0BC1 POST detected startup failure of 2nd Processor.
Processor 2 error Turn off AC and replace CPU#2
0BD0 1st SMBus device address not acknowledged.
A device-less answers to 1st SMBus access.
0BD1 1st SMBus device Error detected.
The error was detected to 1st SMBus access
0BD2 1st SMBus timeout. The timeout occurred to 1st SMBus access.

On-screen error message Description Cause Action 0BD3 2nd SMBus device address not acknowledged.
A device-less answers to 2nd SMBus access.
0BD4 2nd SMBus device Error detected.
The error was detected to 2nd SMBus access 0BD5 2nd SMBus timeout. The timeout occurred to 2nd SMBus access. 0BD6 3rd SMBus device address not acknowledged.
A device-less answers to 3rd SMBus access.
0BD7 3rd SMBus device Error detected.
The error was detected to 3rd SMBus access 0BD8 3rd SMBus timeout. The timeout occurred to 3rd SMBus access. 0BD9 4th SMBus device address not acknowledged.
A device-less answers to 4th SMBus access.
0BDA 4th SMBus device Error detected.
The error was detected to 4th SMBus access 0BDB 4th SMBus timeout. The timeout occurred to 4th SMBus access. 0BDC 5th SMBus device address not acknowledged.
A device-less answers to 5th SMBus access.
0BDD 5th SMBus device Error detected.
The error was detected to 5th SMBus access 0BDE 5th SMBus timeout. The timeout occurred to 5th SMBus access.
0BE8 IPMB device address not acknowledged.
A device-less answers to IPMB access 0BE9 IPMB device Error detected.
The error was detected to IPMB access 0BEA IPMB timeout. The timeout occurred to IPMB access.
8100 Memory Error detected in DIMM group #1 8101 Memory Error detected in DIMM group #2 8102 Memory Error detected in DIMM group #3
A memory error was detected.
DIMM error Replace two DIMMs.
8120 Unsupported DIMM detected in DIMM group #1 8121 Unsupported DIMM detected in DIMM group #2
Unsupported DIMM was detected.
4-6 Troubleshooting · IPMB Access error


On-screen error message Description Cause Action 8122 Unsupported DIMM detected in DIMM group #3
8130 Mismatch DIMM Type detected in DIMM group #1. 8131 Mismatch DIMM Type detected in DIMM group #2. 8132 Mismatch DIMM Type detected in DIMM group #3.
Turn off power and change the jumper setting back to its default position. 8160 Mismatch Processor Speed detected on Processor 1
4-7 Troubleshooting

Error Beep Codes Beep Error Cause Troubleshooting 1-2-2-3 ROM checksum error FMEM checksum error Replace MotherBoard 1-3-1-1 DRAM refresh test error Memory refresh error Replace DIMM 1-3-1-3 Keyboard controller error Keyboard controller error
1-3-3-1 DIMM can not be detected Memory not installed or cannot write.
Check DIMM Mounting or Replace DIMM 1-3-3-1 Memory check error ↑ ↑ 1-3-4-3 DRAM test low byte error Memory address signal fault (low side)
Replace MotherBoard or DIMM 2-2-3-1 Unjust exception test error Unjust exception Replace MotherBoard or CPU 1-2 Video configuration fails Expansion VGA BIOS memory Deployment failure
Replace MotherBoard or Graphic board 1-2 OPTION ROM Checksum failure Expansion ROM BIOS memory Deployment failure
Replace MotherBoard or Option board
4-8 Troubleshooting · Replace MotherBoard

POST Codes The code displayed using the postcard is shown below.
CP Reason 01 Initialize BMC 02 Verify Real Mode 03 Test BMC 04 Get Processor type 06 Initialize system hardware 08 Initialize chipset registers with initial POST values 09 Set in POST flag 0A Initialize Processor registers 0B Enable Processor cache 0C Initialize caches to initial POST values 0E Initialize I/O 0F Initialize the local bus IDE 10 Initialize Power Management 11 Load alternate registers with initial POST values 12 Restore Processor control word during warm boot 13 Initialize PCI Bus mastering devices 14 Initialize keyboard controller 16 BIOS ROM checksum 17 Initialize external cache before memory autosize 18 8254 timer initialization 1A 8237 DMA controller initialization 1C Reset Programmable Interrupt Controller 20 Test DRAM refresh 22 Test 8742 Keyboard Controller 24 Set ES segment register to 4GB 28 Autosize DRAM, system BIOS stops execution here if the BIOS does not detect any usable memory DIMMs 29 Initializes the POST Memory Manager 2A Clear 8 MB base RAM 2C Base RAM failure, BIOS stops execution here if entire memory is bad 2E Test the first 4MB of RAM 2F Initialize external cache before shadowing 32 Test Processor bus-clock frequency 33 Initializes the Phoenix Dispatch Manager 34 Test CMOS 35 RAM Initialize alternate chipset registers 36 Warm start shut down 37 Reinitialize the chipset 38 Shadow system BIOS ROM 39 Reinitialize the cache 3A Autosize cache 3C Configure advanced chipset registers 3D Load alternate registers with CMOS values 41 Check unsupported processor 40 Set Initial Processor speed new 42 Initialize interrupt vectors
4-9 Troubleshooting

CP Reason 44 Initialize BIOS interrupts 45 POST device initialization 46 Check ROM copyright notice 47 Initialize manager for PCI Option ROMs 48 Check video configuration against CMOS 49 Initialize PCI bus and devices 4A Initialize all video adapters in system 4B Display QuietBoot screen 4C Shadow video BIOS ROM 4E Display copyright notice 4F Allocate memory for the multiboot data 50 Display Processor type and speed 52 Test keyboard 54 Set key click if enabled 55 USB initialization 56 Enable keyboard 58 Test for unexpected interrupts 59 Initialize the POST display service 5A Display prompt “Press F2 to enter SETUP” 5B Disable L1 cache during POST 5C Test RAM between 512 and 640k 60 Test extended memory 62 Test extended memory address lines 64 Jump to UserPatch1 66 Configure advanced cache registers 67 Quick init of all AP's early in post 68 Enable external and processor caches 69 Initialize the SMM handler 6A Display external cache size 6B Load custom defaults if required 6C Display shadow message 6E Display non-disposable segments 70 Display error messages 72 Check for configuration errors 74 Test real-time clock 76 Check for keyboard errors 7A Test for key lock on 7C Set up hardware interrupt vectors 7D Intelligent system monitoring 7E Test coprocessor if present 81 POST device initialization routine 82 Detect and install external RS232 ports 83 Configure non-MCD IDE controllers 84 Initialize parallel ports 85 Initialize PC-compatible PnP ISA devices 86 Re-initialize on board I/O ports 87 Configure Mother Board Configurable Devices 88 Initialize BIOS Data Area 89 Enable Non-Maskable Interrupts
4-10 Troubleshooting

CP Reason 8A Initialize Extended BIOS Data Area 8B Test and initialize PS/S mouse 8C Initialize floppy controller 90 Initialize hard disk controller 91 Initialize local bus hard disk controller 92 Jump to UserPatch2 93 Build MPTABLE for multi-processor boards 94 Disable A20 address line 95 Install CD-ROM for boot 96 Clear huge ES segment register 97 Fixup Multi Processor table 98 Search for option ROMs. One long, two short beeps on checksum failure 99 Check for SMART Drive 9A Shadow option ROMs 9C Set up Power Management 9D Initialize security engine 9E Enable hardware interrupts A0 Set time of day A2 Check key lock A4 Initialize typematic rate A8 Erase F2 prompt A9 Prepare boot AA Scan for F2 key stroke AC Print bottom message AE Clear the POST flag B0 Check POST Error B2 POST End B4 Beep once B5 End the Quiet Boot B6 Check Password B7 Configuration ACPI B9 Prepare boot BA DMI Configuration BC Clear parity checkers BD Display Boot Menu BE Clear Screen C0 INT19 C1 Initialize the POST Error Manager C2 Invoke End of POST Error Logging C3 Invoke End of POST Error Message Display C6 Initialize Console Redirection C7 Control Console Port CD Initialize Console Redirection D1 Initialize BIOS stack D3 Find an A20-agnostic place in memory
4-11 Troubleshooting

4-12 Troubleshooting

Preventive Maintenance
The following items are to be periodically maintained every 6 months.

2 Check fan operation ○ ○ Clean it at the same time.
6 Cleaning of CD-ROM head ○ ○ ○ Clean options such as DAT. 7 Check switches ○ ○ ○ Check smoothness. * If any option is added, follow the instructions for that option. MAINTENANCE BY USER
Request the user for maintenance of the following items.

No. Item Frequency Remarks 1 Confirm date and time of the internal clock
2 Check test programs At site adjustment At error occurrence At regular check
3 Execution of test program at failure, and collection of error data
4 Cleaning of head and running section of CD-ROM and DAT

5-2 Preventive Maintenance

Installing Internal Optional Devices
Follow the procedure below to prepare for installing or removing components.
a. Shut down the OS.
b. Press the POWER switch to power off the NEC Express server (the POWER lamp goes
off).
c. Unplug the power cord of the NEC Express server from a power outlet.

The power cord appended to the server as standard.
The power cord appended to the extension power unit.
d. Remove all cables from the rear of the NEC Express server.
e. A clearance of one to two meters must be provided around and over the NEC Express
server.

a. See the section “Preparing for Installation and Removal” described earlier to prepare.
b. Remove the left side cover
c. Remove all power cables from the motherboard, 5.25-inch devices, floppy drive and
SCSI-BP.
d. Remove the two screws on the rear side.

e. Remove the two screws on the front side.

f. Pull out the Power cage gently away from the server chassis.
# Be careful not to force the cage out of the server or not to hook a cable.
screws

Follow the removal procedure in reverse order to install the Power supply unit.

<HDD FAN UNIT>
a. See the section “Preparing for Installation and Removal” described earlier to prepare.
b. Remove the left side cover.
c. Remove the FAN cover (foaming material: gray color).
d. Remove the FAN DC cable from the Motherboard, and pull out the FAN unit.
a. See the section “Preparing for Installation and Removal” described earlier to prepare.
b. Remove the left side cover.
c. Remove the FAN DC cable from the Motherboard.
d. Remove the lock of the rear fan unit. Pull out the FAN unit.

Follow the removal procedure in reverse order to install the FAN unit.
Lock

* After replacing the motherboard, you need to re-set the NvRAM information and SDR FW on the new motherboard. Make backup copies of the current NvRAM information before replacing the motherboard, and restore the information onto the new motherboard after the replacement. For details, see "Management of Setup Information." If the system is unable to make backup copies, set the NvRAM information.
a. See the section “Preparing for Installation and Removal” described earlier to prepare.
b. Remove the left side cover
c. Take out the DIMM boards, PCI boards and cables.
d. Remove the screws securing the Motherboard.

e. Take out the Motherboard carefully to avoid any damage.
Follow the removal procedure in the reverse order to mount the new motherboard. Note the following points in mounting it: 1) Confirm that all the cables are connected correctly, no wire is caught, and all the connectors are connected correctly. 2) Do not bend the springs and gaskets for EMI prevention measures. 3) After mounting the new motherboard, connect the cables firmly by using clamps. 4) For mounting of the heat sink, see Section 5. 5) Mount the provided heat-conduction sheet between the CPU and the heat sink. Be careful not to bend the heat-conduction sheet when mounting it.

a. Set the NEC EXPRESSBUILDER CD-ROM in the CD-ROM drive, and activate the
NEC EXPRESSBUILDER.
b. When the NEC EXPRESSBUILDER becomes active, activate the Offline Maintenance
utility by selecting "Tool" from the menu → "Offline Maintenance Utility" → " Manage System Information".
c. When the Offline Maintenance utility becomes active, select "Save" from the menu.
After that, a message is displayed "asking if you want to format the floppy disk." Respond to the message to format the floppy disk if necessary. The data backup confirmation screen appears after the format confirmation screen. Press the "Enter" key to perform backup processing.
Offline Maintenance Utility Edit/Display HW Logs Edit/Display SW Logs Edit/Display HW Event Logs Display BIOS Setup Information Display System Information Manage System Information Set Remote Maintenance Information Help Exit
Manage System Information Save Menu for Maintenance Persons Exit
(Screen image)

a. Set the NEC EXPRESSBUILDER CD-ROM in the CD-ROM drive, and activate the
NEC EXPRESSBUILDER.
b. When the NEC EXPRESSBUILDER becomes active, activate the Offline Maintenance
utility by selecting "Tool" from the menu → "Offline Maintenance Utility" → " Manage System Information."
c. When the Offline Maintenance utility becomes active, select "Menu for Maintenance
Persons" from the menu.
Offline Maintenance Utility Edit/Display HW Logs Edit/Display SW Logs Edit/Display HW Event Logs Display BIOS Setup Information Display System Information Manage System Information Set Remote Maintenance Information Help Exit

Manage System Information Save Menu for Maintenance Persons Exit
d. Do not care about a notice displayed, and press the Enter key. The system asks you to
enter the password. Enter the password as shown below.
e. Select restoration of the old board information when the following screen appears after
you enter the password:
Menu for Maintenance Persons Restore (at replacement of the mother board) Update Product/Cabinet Information Return to the Previous Menu

(Screen image) · Password >CENVRAM

f. When the "Restore (at replacement of the mother board)" screen appears, insert the
floppy disk containing the backup copies of the NVRAM information into the floppy disk drive, and press the Enter key.
(The following is an image screen, which may be different from the actual one.)
Restore (at replacement of the mother board)
Data Name Device Address Size File Name Setup BIOS Information 1 O BIOS Information 2 O Maintenance Utility Information O BMC Information 1 O BMC Information 2 O BMC Information 3 O ROM Pilot Information 1 O ROM Pilot Information 2 O Product Information O Cabinet Information O Internal useara O Start restoration (Data with a circle shown in the column "Setup" is restored.) Exit: [ESC]
g. Press the Enter key when the following confirmation screen appears.
After that, the NVRAM information is loaded from the floppy disk.

The restore processing is in progress. Wait until the processing is completed.
Execute: [Enter] Cancel: [ESC] h. The screen displays restoration results as shown below.
(The following is an image screen, which may be different from the actual one.)
Restore (at replacement of the mother board): Execution results = normal
Data Name Device Address Size File Name Setup Result BIOS Information 1 O O BIOS Information 2 O O Maintenance Utility Information O O BMC Information 1 O O BMC Information 2 O O BMC Information 3 O O ROM Pilot Information 1 O O ROM Pilot Information 2 O O Product Information O O Cabinet Information O O Internal useara O O Exit: [ESC]
i. Terminate the Offline Maintenance utility when the NVRAM information has been
loaded from the floppy disk.

Set the NVRAM information on the new motherboard by taking the following steps.
a. Set the NEC EXPRESSBUILDER CD-ROM in the CD-ROM drive, and activate the
NEC EXPRESSBUILDER.
b. When the NEC EXPRESSBUILDER becomes active, activate the Offline Maintenance
utility by selecting "Tool" from the menu → "Offline Maintenance Utility" → "Manage System Information."
c. When the Offline Maintenance utility becomes active, select "Menu for Maintenance
Persons" from the menu.
Offline Maintenance Utility Offline Maintenance Utility Manage System Information Execute the Offline Maintenance Utility Set Remote Maintenance Information Return to the Custom Setup Menu ⇓
Manage System Information Save Menu for Maintenance Persons Exit d. Do not care about a notice displayed, and press the Enter key. The system asks you to
enter the password. Enter the password as shown below.
Password >CENVRAM e. Select "Update Product/Cabinet Information" when the following screen appears after
you enter the password:
Menu for Maintenance Persons Restore (at replacement of the mother board) Update Product/Cabinet Information Return to the Previous Menu f. The screen shown below appears. Move the cursor to "Set Default Values" and press the
Enter key.
(Screen image)

Update Product/Cabinet Information Data Name Set Value Manufacturer (Manufacturer Name) NEC Model Name (Product Name) NEC Express5800/1**** (*: Model name) N Code (Product Part) [N8100-***] FR Number (Product Version) FR*.* Serial Number (Product Serial) Cabinet Information 0000*** Set Default Values Update g. The device type list is displayed. Select the target device type.
(If the target device type is not in the list, select an arbitrary device type.)
h. The screen in step 6 is displayed again. Correct the values according to the selected
device.
The following must be changed:
Cabinet attribute 120Me 07 856-060230-001-00 05 06 i. Return to the screen in step 6, move the cursor to "Update," and press the Enter key.
When the confirmation screen shown below appears, press the Enter key again.
Do you want to update the product/cabinet information?
Execute: [Enter] Cancel: [ESC] When the update processing terminates normally, terminate the NEC EXPRESSBUILDER according to the instructions displayed on the screen, and confirm that the device starts up normally.
j. When the NEC Logo screen appears during device startup, press the "F2" key to activate
the BIOS SETUP menu, and set the previously set information again.

Refer to the update procedure document of the Motherboard maintenance parts.
Refer to the Express Server User’s guide.
a. Turn off the power, and then pull the AC cable out. b. Remove a side cover.
c. Extract heat sinks, CPUs, memory boards, PCI boards, etc.
The following procedure explains how to remove a heat sink. (Please DO NOT pull
up straight to draw out a heat sink. If it is removed that way, CPU may be taken out
with heat sink. )



left lightly to remove it. Please DO NOT pull
up straight.
To remove a CPU, follow the procedure for installing a heat sink in reverse order.

d. Remove the screws fixing the Motherboard.

Remove R / M fixed
screws as well.
e. Take out the Motherboard carefully so as to avoid damaging it.
Be sure to respect the specified order when removing components When you remove a motherboard, first remove CPUs and heat sinks (a total of eight screws) before removing retention modules. Refer to the following page.


Retention module Retention module
<Caution> When attaching a Heat sink to the newly installed motherboard, please use the new cool sheet appended to mother board set. Moreover, please remove the old cool sheet of the heat sink with a driver etc.

Please remove the old cool sheet of the heat sink with a driver etc. Heat Sink
CPU socket · CPU socket

To attach the motherboard, follow the removal procedure in the reverse order. Be careful of the following points.
a. Check cables, confirm that wires are not pressed, install all connectors, etc. b. Do not bend the spring for EMI and a gasket.
c. Use clamps to connect cables after Motherboard is installed. d. Follow the instructions below to attach a Heat Sink
The Retention module can be removed by using a minus driver or the removing clip tool.

Socket with dust cover (sponge) removed



Lever




* Caution When removing the retention, hook the hole (designated by the arrow on the picture left) using a thin minus driver or a tool.

Removing the SCSI-B.P.
a. See the section "Preparing for Installation and Removal" described earlier to prepare.
b. Pull out all hard disks.
c. Remove the left side cover.
d. Remove the cable for SCSI-B.P.


e. Remove five screws and pull out the disk cage gently away from the server chassis.



f. Remove four screws, and remove the SCSI-B.P. (with SAF-TE board) gently away from
the disk cage.


Installing the SCSI Back Panel
Follow the removal procedure in reverse order to install the SCSI Back Panel.
SAF-TE board

a. See the section "Preparing for Installation and Removal" described earlier to prepare.
b. Remove the left side cover.
c. Remove all cables connected to the CD-ROM drive.
d. Remove four screws in front of the case, and pull out the CD-ROM bracket gently away
from the server.
e. Remove all screws on the side of the CD-ROM drive.



a. See the section "Preparing for Installation and Removal" described earlier to prepare.
b. Remove the left side cover.
c. Remove all cables connected to the FDD.
d. Remove two screws in front of the case, and pull out the CD-ROM bracket gently away
from the server.
e. Remove all screws from the FDD bracket.


a. Open the front bezel.
b. Use pliers to draw out the pins in the upper and lower corners on the right side of the
server.




a. See the section "Preparing for Installation and Removal" described earlier to prepare.
b. Remove the left side cover.
c. Remove the lock of the front sub bezel.
d. After shifting the front sub bezel up, pull it toward you and remove it.


Lock

a. See the section "Preparing for Installation and Removal" described earlier to prepare.
b. Remove the left side cover.
c. Remove all cables on the front panel board.
d. Remove the four screws on the front panel board.


Refer to the User’s Guide shipped with the option part or Basic Processing Unit. RACK MOUNT CONVERSION
Express5800/120Mf can be converted to a rack mount system. Refer to the User’s Guide shipped with the server.



Maintenance Parts
MAINTENANCE PARTS LIST
Maintenance parts are shown below.

6865330000 FRONT CPU & HDD CAGE1 FAN QTY = 1
6865340000 FRONT PCI & HDD CAGE2 FAN QTY = 2
6887430000 HEATSINK CLIP P533 QTY = 2 / heatsink
6867350000 CPU RETENTION MODULE FOXCONN QTY = 2 / heatsink


7-2 Maintenance Parts

Note s
ABOUT THE USE OF SCREWS
The screws to be used in the Basic Processing Unit are inch screws.
When installing option parts, make sure to use the relevant screws.
Furthermore, be careful because the screws to be used with the Basic Processing Unit are different from those for installing a hard disk, a floppy disk drive or a 5.25 inch device.
When a screw is already attached to the option part, always use the screw that comes with the device.
When transporting the Basic Processing Unit, use the package box of the exclusive use.
When using another box, use some buffering material to defend it against the impact.
At least three persons are required to carry the server (Max 44kg).

8-2 Notes



■
■
■
■
■
■
■
■
■
■
■
■
■