Instruction/ maintenance manual of the product GVFS20N Napoleon Fireplaces
Go to page of 16
1 W415-0559 / 02.15.06 W415-0559 / 02.07.06.
2 W415-0559 / 02.15.06 WHA T T O DO IF Y OU SMELL GAS Do not touch any electrical switch. If you cannot reach your gas supplier , call the fire department. Do not try to light any appliance. Do not use any phone in your building. Immediately call your gas supplier from a neighbor's phone.
3 W415-0559 / 02.15.06 W ARNING • Under no cir cumstances should this heater be modified. • Pr ovide adequate v entila tion and combustion air . Pr ovide adequa te accessibility c learance f or servicing and oper ating the hea ter . Ne ver obstr uct the front opening of the heater .
4 W415-0559 / 02.15.06 NAPOLEON products are manufactured under the strict Standard of the world recognized ISO 9001 : 2000 Quality Assurance Certifi cate. NAPOLEON products are designed with superior components and materials, assembled by trained craftsmen who take great pride in their work.
5 W415-0559 / 02.15.06 FOR YOUR SA TISF ACTION, THIS FIREPLACE HAS BEEN TEST -FIRED TO ASSURE ITS OPERA TION AND QUALITY! Maximum input is 23,000 BTU/hr for natural gas and propane.
6 W415-0559 / 02.15.06 MAINT AIN THESE MINIMUM CLEARANCES T O COMB USTIBLES: A. 4" B. 2" * C. 2" Pr ovide adequate v entilation and combustion air . Provide adequate accessibility clearance for servicing and operating the stove. Never obstruct the front opening of the stov e.
7 W415-0559 / 02.15.06 BL O WER INST ALLA TION GAS INST ALLA TION 1. Install rigid black pipe, or 1/2" type L copper tubing with a shut-off valve to the stove. 2. Seal and tighten the gas line securely to a fl ex connector . DO NOT KINK FLEXIBLE CONNECTOR.
8 W415-0559 / 02.15.06 FINISHING 1. Lift the top cast piece off of the unit. 2. Detach the front cast piece from the side pieces by remov- ing the screws from the brackets located in the upper inside corners.
9 W415-0559 / 02.15.06 3. Place the hole in the underside of log #3 onto the locating screw , on the right side of the burner . The bottom branch of log #3 sits infront of, and against, the right end of log #2.
10 W415-0559 / 02.15.06 • Do not touch any electric switch; do not use any phone in your building. • Immediately call your gas supplier from a neighbour ’s phone. Follow the gas supplier ’s instructions. • If you cannot reach your gas supplier , call the fi re de- partment.
11 W415-0559 / 02.15.06 Air shutter adjustment must only be done by a qualifi ed gas installer! ADJUSTMENTS VENTURI ADJUSTMENT 1 . In order to properly clean the burner and pilot assembly , remove the logs exposing both assemblies.
12 W415-0559 / 02.15.06 Contact your dealer for questions concerning prices and availability of replacement parts. Normally all parts can be ordered through your Napoleon dealer or distributor. When ordering replacement parts always give the following information: 1.
13 W415-0559 / 02.15.06 * W ARNING: This is a fast acting thermocouple. It is an integral safety component. Replace only with a fast acting thermocouple supplied by Wolf Steel Ltd.
14 W415-0559 / 02.15.06 Main burner goes out; pilot stays on. Pilot fl ame is not large enough or not engulfi ng the thermo- pile - service or replace Oxygen Depletion Sensor System - correct piping and/or regulator to provide correct pressure Thermopile shorting - clean thermopile connection to the valve.
15 W415-0559 / 02.15.06 Pilot goes out while standing; Main burner is in ‘OFF’ position. Gas piping is undersized. - turn on all gas appliances and see if pilot fl ame fl utters, diminishes or extinguishes, especially when main burner ignites. Monitor appliance supply working pressure.
16 W415-0559 / 02.15.06 Fireplace Service History This fireplace must be serviced annually depending on usage DA TE DEALER NAME SERVICE TECHNICIAN NAME SERVICE PERFORMANCE SPECIAL CONCERNS NOTES.
An important point after buying a device Napoleon Fireplaces GVFS20N (or even before the purchase) is to read its user manual. We should do this for several simple reasons:
If you have not bought Napoleon Fireplaces GVFS20N yet, this is a good time to familiarize yourself with the basic data on the product. First of all view first pages of the manual, you can find above. You should find there the most important technical data Napoleon Fireplaces GVFS20N - thus you can check whether the hardware meets your expectations. When delving into next pages of the user manual, Napoleon Fireplaces GVFS20N you will learn all the available features of the product, as well as information on its operation. The information that you get Napoleon Fireplaces GVFS20N will certainly help you make a decision on the purchase.
If you already are a holder of Napoleon Fireplaces GVFS20N, but have not read the manual yet, you should do it for the reasons described above. You will learn then if you properly used the available features, and whether you have not made any mistakes, which can shorten the lifetime Napoleon Fireplaces GVFS20N.
However, one of the most important roles played by the user manual is to help in solving problems with Napoleon Fireplaces GVFS20N. Almost always you will find there Troubleshooting, which are the most frequently occurring failures and malfunctions of the device Napoleon Fireplaces GVFS20N along with tips on how to solve them. Even if you fail to solve the problem, the manual will show you a further procedure – contact to the customer service center or the nearest service center