Instruction/ maintenance manual of the product GEM-P1632 Napco Security Technologies
Go to page of 16
R INS TALLATION INS TALLATION INST RUCTIONS INST RUCTIONS GEM-RP3DGT L Digital Ke ypad W I982A 6/99 © Napco 1999 Quick Start: 1. Referring to the control panel wiring diagram, connect siren, aux. power, pgm. output, remote bus, earth ground, zone and telephone wiring.
2.
INTRODUCTION The GEM-RP3DGTL is a dual 7-segment digital keypad that is compat ible with the NAPCO GEM-Series GEM-P816, P1632, P3200 & P9600 control-panels.
EASY PROGRAM MODE OVERVIEW ENTERING THE EASY KEYPAD PROGRAM MODE 1 Enter the Dealer Security Code (default = 456789) for a new panel or enter your custom Dealer Program Code if programmed and press A 2 Press NO ( F ) repeatedly until function “ 17 “ (Activate Program Mode) is displayed.
Total Number of Zones in Area 1 (Appears for New Panel Only) Press the A button and then directly enter the total number of zones to be programmed for Area 1. Valid entries are from 01 to 32. Directly enter the total number of zones, including leading zeros.
Entry/Exit Zones in Area 1 (Appears for New Panel Only) Press the A button and then directly enter the zone number of any zones which are to be used as Entry/Exit zones. Valid entries are from 01 to 32. Di- rectly enter each zone number, including leading zeros.
7 Central Station Receiver 1 Format From the table below, enter the central station's receiver format. Use number buttons 1 through 9 . NOTE: Press G0 for a zero and 0 for a blank space (•). Press G 1 through G 4 for letters B–E, respectively.
RF Transmitter Programming (For wireless systems only. Also see Quick Method, which follows) Press the A button and for each transmitter (key fob transmitters also), then directly enter: 1 The zone number (01–32) to which the transmitter will be mapped, including leading zeros.
9 Key Fob Transmitters Keyfobs can be programmed as “Arm/Disarm” devices using the ON and OFF buttons (refer to control panel installation instructions). Press the A button and for each Key Fob Transmitter, enter: 1 The Key Fob Transmitter number (01–15).
Total Number of Zones and Keypads in Area 1. Total Number of Zones and Keypads in Area 2. (Appears for New Panel Only) 1 Press the A button and then press 3 to select the total number of zones to be programmed for Area 1. Valid entries are from 08 to 24 in multiples of 4.
11 Central Station Receiver 1 Format From the table below, enter the central station's receiver format. Use number buttons 1 through 9 . NOTE: Press G0 for a zero and 0 for a blank space (•). Press G 1 through G 4 for letters B–E, respectively.
12 RF Transmitter Programming (For wireless systems only. Also see Quick Method, which follows) Press the A button and for each transmitter and directly enter: 1 The zone number (01–96) to which the transmitter will be mapped, including leading zeros.
Key Fob Transmitters Keyfobs can be programmed as “Arm/Disarm” devices using the ON and OFF buttons (refer to control panel installation instructions). Press the A button and for each Key Fob Transmitter, enter: 1 The Key Fob Transmitter number (01–15).
DIRECT ADDRESS PROGRAM MOD E This is an extension of the Dealer Program Mode. This method of programming is used in conjunction with the Keypad Programming Worksheets contained in the control panel programming guide. Refer to these worksheets to identify the 4-digit location (address) of the feature to be programmed.
15.
NAPCO SECURITY SYSTEMS, INC. (NAPCO) war- rants its products to be free from manufacturing defects in materials and workmanship for thirty-six months fol- lowing the date of manufacture. NAPCO will, within said period, at its option, repair or replace any product failing to operate correctly without charge to the original pur- chaser or user.
An important point after buying a device Napco Security Technologies GEM-P1632 (or even before the purchase) is to read its user manual. We should do this for several simple reasons:
If you have not bought Napco Security Technologies GEM-P1632 yet, this is a good time to familiarize yourself with the basic data on the product. First of all view first pages of the manual, you can find above. You should find there the most important technical data Napco Security Technologies GEM-P1632 - thus you can check whether the hardware meets your expectations. When delving into next pages of the user manual, Napco Security Technologies GEM-P1632 you will learn all the available features of the product, as well as information on its operation. The information that you get Napco Security Technologies GEM-P1632 will certainly help you make a decision on the purchase.
If you already are a holder of Napco Security Technologies GEM-P1632, but have not read the manual yet, you should do it for the reasons described above. You will learn then if you properly used the available features, and whether you have not made any mistakes, which can shorten the lifetime Napco Security Technologies GEM-P1632.
However, one of the most important roles played by the user manual is to help in solving problems with Napco Security Technologies GEM-P1632. Almost always you will find there Troubleshooting, which are the most frequently occurring failures and malfunctions of the device Napco Security Technologies GEM-P1632 along with tips on how to solve them. Even if you fail to solve the problem, the manual will show you a further procedure – contact to the customer service center or the nearest service center