M GT - 16 OWNER’S MANUAL 16-Channel Mini UHF Wireless Instrument System.
Contents 2 Introduction ............................................................................................................................. 2 Using this Manual .................................................................................
System Features MGT -16 System Features UHF wireless system for guitar/bass • 16 user -selectable PLL frequencies • for interference-free operation Up to 250’ operating range, line-of-sigh.
4 Quick User Controls Guide MGT -16 Instrument Receiver POWE R AC T 10 13 14 11 12 2 1 3 6 5 15 IR PO LO RX LEVE L CHANNE L 1 234 SQ OFF ON 7 8 9 16 4.
1. ASC ™ IR SYNC INFRARED LED WINDOW For downloading selected Channel (Frequency) to transmitter 2. POWER SWITCH Select OFF/MUTE/ON (MUTE=power On, audio out put highly attenuated) 3. VOLUME CONTROL Adjusts the audio output level — at maximum setting the gain will be about +4dB over a direct instrument-to- cord-to-amp connection 4.
6 Quick User Controls Guide MT -16A/R Instrument T ransmitter 17. POWER SWITCH T o power transmitter Off/On 18. 15dB A TTENUATION P AD Select to r educe the input gain b y 15dB for hi gher level au dio input signals 19. INPUT ¼” PLUG Connect directly into guitar/bass output jack 20.
7 IR Sync Selected Frequency Download from MGT -16 Receiver to MT -16A/R T ransmitter (1) ASC ™ IR SYNC INFRARED LED WINDOW For downloading selected Channel (Frequency) to transmitter (21) IR RECEPTOR SENSOR/WINDOW Infrared LED sensor for l inking the TX to the RX du ring IR frequency download.
powers the u nit and will not charge Ni MH rechargeable batteries if installed. F or battery operation the AC adapter must be disconnected. Note: For quietest optimal perf ormance, use the AC/DC adapter as battery operation raises the noise floor around 4 dB.
9 When the RF Signal LED (10) on the rec eiver lights up, the system frequency is properly synchronize d. T o change to a different frequency , reset the Frequency Select DIP Switches (4) and sync t he transmit ter again to the new selected frequency first, after turning the transmitte r off and th en on again.
10 trim-pot counterclockwise reduces overall system audi o output (t hus lowering distortion but raising background noise), while turning clockwise increases overall system audi o output (t hus lowering background noise but r aising disto rtion).
11 Specifications MGT -16 SYSTEM Frequency Response 50Hz–16kHz (-3dB) Dynamic Range 120dB Oscillating System Phase Lock Loop (PLL) T otal Harmonic Distortion (THD) <0.
Cautions and T roubleshooting 12 No or Low Audio If you are not getting audio through the system, carefully re-check all setups. Especially note that the receiver and transmitter must be set to operate on the same RF channel.
13 Miscellaneous T ips The receive r antennas should be ke pt • away from a ny metal su rfaces whene ver possible as they can r eflect away o r shield the incoming RF signal. When insert ing batteri es, make sur e they • are inserte d with the correct pola rity .
14 MGT -16 DIP-Switch Frequency Selection Chart Frequency Plan: 902.4MHz-923.7MHz (16 Channels) U.S. Channel Selection Frequency 9 913.9 10 914.0 11 916.0 12 917.9 13 919.7 14 920.0 15 921.1 16 923.7 Channel Selection Frequency 1 902.4 2 904.8 3 905.4 4 906.
15 One-Y ear Limited Warranty Nady Systems , Inc. warran ts to the ori ginal consume r purchaser t hat the unit is free from any defects in material or workmanship for a period of one year from the date of original retail purchase. If any such defect is discovered within the warranty period, Nady Systems, Inc.
6701 Shellmound Street | Emeryville, CA USA 94608 T 510.652.2411 | F 510.652.5075 | www .nady .com.
An important point after buying a device Nady Systems MGT16A (or even before the purchase) is to read its user manual. We should do this for several simple reasons:
If you have not bought Nady Systems MGT16A yet, this is a good time to familiarize yourself with the basic data on the product. First of all view first pages of the manual, you can find above. You should find there the most important technical data Nady Systems MGT16A - thus you can check whether the hardware meets your expectations. When delving into next pages of the user manual, Nady Systems MGT16A you will learn all the available features of the product, as well as information on its operation. The information that you get Nady Systems MGT16A will certainly help you make a decision on the purchase.
If you already are a holder of Nady Systems MGT16A, but have not read the manual yet, you should do it for the reasons described above. You will learn then if you properly used the available features, and whether you have not made any mistakes, which can shorten the lifetime Nady Systems MGT16A.
However, one of the most important roles played by the user manual is to help in solving problems with Nady Systems MGT16A. Almost always you will find there Troubleshooting, which are the most frequently occurring failures and malfunctions of the device Nady Systems MGT16A along with tips on how to solve them. Even if you fail to solve the problem, the manual will show you a further procedure – contact to the customer service center or the nearest service center