Page 1 of the Murphy GPS Kit user manual — HelmView ™ Accessory Kit
Page 1 · click to enlarge
Page 1
Murphy GPS Kit — HelmView ™ Accessory Kit diagram (page 1)
Fig. 1 · HelmView ™ Accessory Kit
Murphy GPS Kit — HelmView ™ Accessory Kit diagram (page 1)
Fig. 2 · HelmView ™ Accessory Kit

HelmView ™ Accessory Kit

Installation Guide

Page 2 of the Murphy GPS Kit user manual — BEFORE BEGINNING INSTALLATION OF THIS MURPHY PRODUCT:
Page 2 · click to enlarge
Page 2

In order to consistently bring you the highest quality, full featured products, we reserve the right to change our specifications and designs at any time. The latest version of this manual can be found at www.fwmurphy.com

Warranty - A limited warranty on materials and workmanship is given with this FW Murphy product. A copy of the warranty may be viewed or printed by going to www.fwmurphy.com/support/warranty.htm

Murphy GPS Kit — BEFORE BEGINNING INSTALLATION OF THIS MURPHY PRODUCT: diagram (page 2)
Fig. 3

Please read the following information before installing.

BEFORE BEGINNING INSTALLATION OF THIS MURPHY PRODUCT:

  • Read and follow all installation instructions.
  • Please contact FW MURPHY immediately if you have any questions.
Page 3 of the Murphy GPS Kit user manual — BEFORE BEGINNING INSTALLATION OF THIS MURPHY PRODUCT:
Page 3 · click to enlarge
Page 3
Page 3 of the Murphy GPS Kit user manual — BEFORE BEGINNING INSTALLATION OF THIS MURPHY PRODUCT:
Page 4 of the Murphy GPS Kit user manual — (THIS PAGE INTENTIONALLY LEFT BLANK)
Page 4 · click to enlarge
Page 4

(THIS PAGE INTENTIONALLY LEFT BLANK)

Page 5 of the Murphy GPS Kit user manual — HelmView Mounting Kit
Page 5 · click to enlarge
Page 5

HelmView Accessory Kit Structure

The following accessory kits are available for the HelmView Model HV1000:

  • HelmView Mounting Kit (PN 78-70-0232)
  • GPS Kit (PN 78-70-0261)
  • NMEA Backbone Kit (PN 78-70-0266)
  • Multisensor Kit (PN 78-70-0267)
  • EVC Kit (PN 78-70-0366)
  • Gimbal Mount (PN 78-70-0260)

HelmView Mounting Kit

Kit includes mounting hardware and plastic drilling/cutout template. Map card is included with optional GPS Kit.

Murphy GPS Kit — HelmView Mounting Kit diagram (page 5)
Fig. 4 · HelmView Mounting Kit
Murphy GPS Kit — HelmView Mounting Kit diagram (page 5)
Fig. 5 · HelmView Mounting Kit
Page 6 of the Murphy GPS Kit user manual — NMEA Backbone Kit
Page 6 · click to enlarge
Page 6

GPS Kit

This kit includes a Map card and connections.

Murphy GPS Kit — GPS Kit diagram (page 6)
Fig. 6 · GPS Kit

NMEA Backbone Kit

Murphy GPS Kit — NMEA Backbone Kit diagram (page 6)
Fig. 7 · NMEA Backbone Kit
Page 7 of the Murphy GPS Kit user manual — Gimbal Mount
Page 7 · click to enlarge
Page 7

Multisensor Kit

Murphy GPS Kit — Multisensor Kit diagram (page 7)
Fig. 8 · Multisensor Kit

Gimbal Mount

Murphy GPS Kit — Gimbal Mount diagram (page 7)
Fig. 9 · Gimbal Mount
Murphy GPS Kit — Gimbal Mount diagram (page 7)
Fig. 10 · Gimbal Mount
Page 8 of the Murphy GPS Kit user manual — Specifications
Page 8 · click to enlarge
Page 8

Remote Keypad

Murphy GPS Kit — Remote Keypad diagram (page 8)
Fig. 11 · Remote Keypad

The Remote Keypad works with Murphy’s PV1000 and HV1000 model displays. It allows a user to enter keypad commands whenever display installations are not conveniently located for easy access.

The keypad contains the same navigation, menu and selection keys as found on the displays, making it an easy transition to use. Fault lights, just like the ones found on the displays, are located in the corners of the keypad. An audible alarm with a one-touch key for temporarily disabling is provided, making it easy to recognize and address faults and alarms.

Specifications

I. Electrical

I. Mechanical

Processor: PIC18F2510 Flash Memory: 32 Kbytes RAM: 1536 bytes SRAM Backlighting: LED, 7400 mcd Operating Voltage: 6 to 32 VDC, protected against reverse polarity and load-dump Power Consumption: 3.2 W maximum Connection: 2 Deutsch DT 6-pin connectors Keyboard: 7 Membrane Switch Keys Audible Alarm: 70dB minimum

  • Mounting Type: Screw-on clamp Dimensions (W x H):
  • 3.88 x 3.88 inch (Landscape)
  • Panel Mount Depth – 0.5922 inch
  • Unit Depth – 2.173 inch Cutout for Panel Mounting (Diameter): 2.062 inch Case Material: Polycarbonate Weight: 0.4 lb (180 g)

I. Environmental

Operating Temperature: -40 to 70°C (-40° to 158°F) Storage Temperature: -55 to 85°C (-67° to 185°F) Emissions: SAE J1113, IEC 60945, EN 12895, EN 61000

Page 9 of the Murphy GPS Kit user manual — Electrical Connection
Page 9 · click to enlarge
Page 9

Product Dimensions

Murphy GPS Kit — Product Dimensions diagram (page 9)
Fig. 12 · Product Dimensions
Murphy GPS Kit — Product Dimensions diagram (page 9)
Fig. 13 · Product Dimensions

Electrical Connection

Murphy GPS Kit — Electrical Connection diagram (page 9)
Fig. 14 · Electrical Connection
Murphy GPS Kit — Electrical Connection diagram (page 9)
Fig. 15 · Electrical Connection
Page 10 of the Murphy GPS Kit user manual — Mounting Instructions
Page 10 · click to enlarge
Page 10

Mounting Instructions

Mounting options are shown below.

Murphy GPS Kit — Mounting Instructions diagram (page 10)
Fig. 16 · Mounting Instructions
Murphy GPS Kit — Mounting Instructions diagram (page 10)
Fig. 17 · Mounting Instructions

Mounting option 1: On a mounting flange and 1-inch pipe (not included in kit) using provided flange, screws and washers.

Mounting option 2: Surface mount using screws (8-32) of suitable length.

Page 11 of the Murphy GPS Kit user manual — Maximum Drop Line Length
Page 11 · click to enlarge
Page 11

Installing an NMEA 2000 ® Network

Installing an NMEA 2000 consists of interconnecting NMEA 2000 electronic devices using plug-and-play cables and connectors. The following pages provide a brief description of how to setup a NMEA 2000 network using five basic steps:

1. Cable and Connector Network Basics
2. Installing Terminators
3. Supplying Power
4. Grounding the Network
5. Checking the Network

Please note that this installation guide contains a brief description of the basic concepts of installing an NMEA 2000 network. You can learn more about installing NMEA 2000 networks by contacting the National Marine Electronics Association (NMEA) at www.nmea.org and consulting the following documents:

  • NMEA 2000 Standard for Serial-Data Networking of Marine Electronic Devices
  • NMEA Installation Standards

Cable and Connector Network Basics

Network Topology

The NMEA 2000 cable system uses a trunk (sometimes referred to as the backbone), drop line, drop tee, and termination resistor.

The NMEA 2000 cable system includes five wires within a single waterproof cable: two signal wires, power and ground wires, and a drain wire. The drain wire shields the signal, power, and ground wires from external Radio Frequency Interference (RFI) and helps reduce RFI emission from the cable.

Maximum Cable Distance

The cable distance between any two points in the cable system must not exceed 100 meters (328 feet) for the Micro cable.

Maximum Drop Line Length

The maximum cable distance from any device on a branching drop line to the trunk link is 6 meters (20 feet).

Page 12 of the Murphy GPS Kit user manual — Micro Power Capability
Page 12 · click to enlarge
Page 12

Maximum Number of Devices

A maximum of 50 physical devices shall be connected to the network, and the disconnection of any device shall not interrupt any other device on the network.

NMEA 2000 Cable

Micro cables contain five wires: One twisted pair (red and black) for 12VDC power, one twisted pair (blue and white) for signal and a drain wire (bare).

Installing Terminators

Termination resistors are attached to each end of the trunk cable to reduce reflections of the communication signals on the network. If you do not use termination resistors as described, the network will not operate properly. Termination resistors are typically connected directly to the last tee on the trunk line although they can be connected to a cordset extending from the last tee on a trunk line.

Supplying Power

NMEA 2000 networks can use a power supply originating from a single-point connection to the vessel’s 12 volt battery or one or more isolated power supplies distributed along the network, but not a combination of battery and power supply connections. Over current protection should be provided and should be sized in accordance with ABYC E-11, AC and DC ELECTRICAL SYSTEMS ON BOATS, taking into consideration the smallest gauge of cable being used for the backbone or drop cables. The NET-S wire is connected to the positive side of the battery while NET-C is connected to the negative side of the battery.

Micro Power Capability

Micro cable is rated to 4 amps, however strategic placement of the power source could support higher current. For example, 8 amps of power could be supplied to the middle of the trunk where 4 amps is supplied to both sides of the power tap. It can handle large loads as long as no more than 4 amps is drawn through any single segment of he trunk line. However, cable resistance may limit your application to less than 4 amps.

Page 13 of the Murphy GPS Kit user manual — Checking Your Network
Page 13 · click to enlarge
Page 13

Maximum Power Supply Voltage Drop

The NMEA 2000 network is designed to work properly as long as there is no more than a 1.5 volt difference in the power supply voltage between any two devices on the network. Therefore, you should perform an estimate of the voltage drop across a network using the following equation:

Voltage Drop = 0.1 x Network Loads x Network Length x Cable Resistance / 100

WhereNetwork Loads is sum of Load Equivalent Numbers (LEN) for all devices

Network Length is in meters

Cable resistance is in ohms/100 meters

Ground the Network

The NMEA 2000 network should be grounded at ONE location. Grounding at more than one location may produce ground loops, which can cause problems with communications on the network. In addition to the ground wire, connect the drain or SHEILD wire at the supply ground location and NO other place.

Checking Your Network

Verify that the network has been correctly designed and installed by reviewing the following checklist:

  • Number of devices does not exceed 50
  • Maximum Micro cable distance between any two devices does not exceed 100 meters (328 feet)
  • No drop should be greater than 6 meters (20 feet)
  • Termination resistors are installed on both ends of the trunk
  • The network is grounded at a single location
  • The SHIELD wire is connected to a single point, the supply ground
Page 14 of the Murphy GPS Kit user manual — Maximum Power Supply Voltage Drop
Page 14 · click to enlarge
Page 14

MURPHY, the Murphy logo, HelmView™ and HV1000™ are registered and/or common law trademarks of Murphy Industries, Inc. This document, including textual matter and illustrations, is copyright protected by Murphy Industries, Inc., with all rights reserved. (c) 2007 Murphy Industries, Inc. Other third party product or trade names referenced herein are the property of their respective owners and are used for identification purposes only.

Page 15 of the Murphy GPS Kit user manual — Maximum Power Supply Voltage Drop
Page 15 · click to enlarge
Page 15
Murphy GPS Kit — Maximum Power Supply Voltage Drop diagram (page 15)
Fig. 18 · Maximum Power Supply Voltage Drop
Sources

References & links

Pages referenced in this manual — manufacturer, support and downloads.

Ask about the Murphy GPS Kit

Owners and our team usually reply within a day — and your question helps the next person too.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
No questions yet about the Murphy GPS Kit

Be the first to ask — other owners or our team will answer.

Original document

Murphy GPS Kit manual PDF

15 pages·348 KB·GPS Receiver·PDF
Click any page above to open it here
Page 1 / …
100%
Loading pages…