EN
Multiquip logo
Official user manual

Multiquip GBC

46 pages·4.8 MB·Light Therapy Device·PDF·ENDEFRITNLJA
Multiquip GBC
Table of Contents 80 sections Operation and Parts Manual · GloBug SERIES · MODEL GBC Serial No. G2300001 and Above cart type lighting system · Revision #0 (06/24/13) · … ShowHide
Page 1 of the Multiquip GBC user manual — Operation and Parts Manual
Page 1 · click to enlarge
Page 1

Operation and Parts Manual

GloBug SERIES

MODEL GBC Serial No. G2300001 and Above cart type lighting system

Revision #0 (06/24/13)

To find the latest revision of this

publication, visit our website at:

www.multiquip.com

THIS MANUAL MUST ACCOMPANY THE EQUIPMENT AT ALL TIMES.

Page 2 of the Multiquip GBC user manual — NOTES
Page 2 · click to enlarge
Page 2

NOTES

Page 3 of the Multiquip GBC user manual — NOTES
Page 3 · click to enlarge
Page 3
Multiquip GBC — NOTES diagram (page 3)
Fig. 1
Multiquip GBC — NOTES diagram (page 3)
Fig. 2
Multiquip GBC — NOTES diagram (page 3)
Fig. 3
Multiquip GBC — NOTES diagram (page 3)
Fig. 4
Multiquip GBC — NOTES diagram (page 3)
Fig. 5
Multiquip GBC — NOTES diagram (page 3)
Fig. 6
Multiquip GBC — NOTES diagram (page 3)
Fig. 7
Page 4 of the Multiquip GBC user manual — FUEL CHEMICAL WARNING
Page 4 · click to enlarge
Page 4

FUEL CHEMICAL WARNING

Gasoline engine exhaust and some of its constituents are known to cause cancer, birth defects and other reproductive harm.

Page 6 of the Multiquip GBC user manual — NOTICE
Page 6 · click to enlarge
Page 6

Parts Ordering Procedures

Ordering parts has never been easier!

www.multiquip.com

Choose from three easy options:

EffectiveJanuary 1 st , 2006

order via internet (dealers only): Order parts on-line using Multiquip’s SmartEquip website! I View Parts Diagrams I Order Parts I Print Specifi cation Information

If you have an MQ Account, to obtain a Username and Password, E-mail us at: parts@multiquip. com.

To obtain an MQ Account, contact your District Sales Manager for more information.

Goto www.multiquip.com and click on

Use the internet and qualify for a 5% discount on Standard orders for all orders which include complete part numbers.*

Order Parts to log in and save!

order via Fax (dealers only): All customers are welcome to order parts via Fax. domestic (us) Customers dial: 1-800-6-PARTS-7 (800-672-7877)

Fax your order in and qualify for a 2% discount on Standard orders for all orders which include complete part numbers.*

order via phonedomestic (us) dealers Call: 1-800-427-1244

non-dealer Customers: Contact your local Multiquip Dealer for parts or call 800-427-1244 for help in locating a dealer near you.

International Customers should contact their local Multiquip Representatives for Parts Ordering information.

When ordering parts, please supply: Ì dealer account number Ì dealer name and address Ì shipping address (if different than billing address) Ì return Fax number Ì applicable model number Ì Quantity, part number and description of each part

Ì specify preferred method of shipment: UPS/Fed Ex DHL I Priority One Truck I Ground I Next Day I Second/Third Day

NOTICE

All orders are treated as Standard Orders and will ship the same day if received prior to 3PM PST.

We aCCept all maJor Credit Cards!

Best deal!

Page 7 of the Multiquip GBC user manual — NOTICE
Page 7 · click to enlarge
Page 7

Safety Information

Do not operate or service the equipment before reading the entire manual. Safety precautions should be followed at all times when operating this equipment. Failure to read and understand the safety messages and operating instructions could result in injury to yourself and others.

Potential hazards associated with the operation of this equipment will be referenced with hazard symbols which may appear throughout this manual in conjunction with safety messages.

saFety messages

The four safety messages shown below will inform you about potential hazards that could injure you or others. The safety messages specifi cally address the level of exposure to the operator and are preceded by one of four words: danger, Warning, Caution or notiCe.

saFety symBols

Indicates a hazardous situation which, if not avoided, WILL result in death or serious inJury.

Indicates a hazardous situation which, if not avoided, Could result in death or serious inJury.

Indicates a hazardous situation which, if not avoided, Could result in minor or moderate inJury.

NOTICE

Addresses practices not related to personal injury.

Page 8 of the Multiquip GBC user manual — general saFety
Page 8 · click to enlarge
Page 8

Safety Information

general saFety

NOTICE

This equipment should only be operated by trained and

qualifi ed personnel 18 years of age and older.

never operate this equipment without proper protective

clothing, shatterproof glasses, respiratory protection, hearing protection, steel-toed boots and other protective devices required by the job or city and state regulations.

Whenever necessary, replace nameplate, operation and

safety decals when they become diffi cult read.

Manufacturer does not assume responsibility for any

Multiquip GBC — general saFety diagram (page 8)
Fig. 8 · general saFety

accident due to equipment modifi cations. Unauthorized equipment modifi cation will void all warranties.

never use accessories or attachments that are not

recommended by Multiquip for this equipment. Damage to the equipment and/or injury to user may result.

feeling well due to fatigue, illness or when under medication. never operate this equipment under the infl uence of

ALWAYS know the location of the nearest

fi re extinguisher.

drugs or alcohol.

ALWAYS know the location of the nearest

fi rst aid kit.

ALWAYS know the location of the nearest phone or keep

ALWAYS check the equipment for loosened threads or

a phone on the job site. Also, know the phone numbers of the nearest ambulance, doctor and fi re department. This information will be invaluable in the case of an emergency.

bolts before starting.

do not use the equipment for any purpose other than

its intended purposes or applications.

Page 9 of the Multiquip GBC user manual — NOTICE
Page 9 · click to enlarge
Page 9

Safety Information

lighting system saFety

lamp saFety

never disconnect any emergency or safety devices.

never attempt to replace lamp with the power on.

These devices are intended for operator safety. Disconnection of these devices can cause severe injury, bodily harm or even death. Disconnection of any of these devices will void all warranties.

Always unplug the power cord from the generator or power source when changing the lamp.

ALWAYS allow a suffi cient amount of time for the lamp to cool

before changing. The possibility exists of severe burns.

never attempt service on a running machine.

never use force when installing the lamp. Excessive force

NOTICE

could cause the lamp to break, causing bodily harm.

To prevent the lighting system from overturning, never

NOTICE

use in winds that exceed 22 mph (10 m/s).

never leave any grease or oil residue on lamp surface

The lighting system should only be used in temperatures

when replacing or removing lamp. This can create hot spots, reducing the service life of the lamp.

between 23° to 104°F (-5° to 40° C). Failure to comply with these operating parameters could cause the lamp to malfunction and shorten the ballast life.

ALWAYS make sure lamp surface is clean and dry.

ALWAYS replace with MQ recommended type lamp. See

ALWAYS keep the lighting system in proper running

parts section of this manual.

condition.

If applicable, ALWAYS make sure the lamp guard is

Fix damage to lighting system and replace any broken

installed correctly. never deform the lamp guard.

parts immediately.

never unplug the lamp’s AC power cable during

ALWAYS store equipment properly when it is not being

operation.

used. Equipment should be stored in a clean, dry location out of the reach of children and unauthorized personnel.

ALWAYS have a trained technician to install and

remove lamp or replace any damaged fi xture wiring.

Page 10 of the Multiquip GBC user manual — NOTICE
Page 10 · click to enlarge
Page 10

Safety Information

Balloon saFety

eleCtriCal saFety

Multiquip GBC — Balloon saFety diagram (page 10)
Fig. 9 · Balloon saFety

Lighting system is equipped with a ground pin on the

or unzip the balloon envelope when the lamp is on.

power plug. For your protection, ALWAYS complete the grounding path. never insert the AC power plug into a 2-prong receptacle to operate lighting system.

When applying power to the lighting system, ALWAYS

ALWAYS keep the balloon away from sharp objects and

connect the AC power plug to a 3-prong receptacle that is grounded. The possibility exists of electrical shock, electrocution and even death if the lighting system is not grounded.

excessive amounts of heat.

NOTICE

To prevent balloon deformation, never use lighting

system in strong winds.

never operate lighting system or

handle any electrical equipment while standing in water, while barefoot, while hands are wet or in the rain. A dangerous electrical shock could occur, causing severe bodily harm or even death.

do not place the balloon inside its protective cover

until the lamp has had a suffi cient amount of time to cool down. This will prevent the balloon’s nylon cover from being burned (touching the lamp surface).

ALWAYS place the balloon inside its protective cover

ALWAYS make sure the area above

after each use. This will prolong the life of the balloon material, keeping it protected from harsh environmental elements.

the lighting system is open and clear of overhead power lines and other obstructions. Contact with overhead power lines or other obstructions could result in equipment damage, electrical shock, electrocution and even death.

Replace balloon immediately if damaged. A damaged

balloon will not infl ate properly, and may become more damaged by touching the hot lamp surface.

do not use excessive force when zipping and unzipping

power Cord/Cable safety

the balloon. Be gentle with the zipper mechanism. If the zipper is broken, the balloon will become unusable.

never let power cords or cables lay in water.

generator saFety

never use damaged or worn cables or cords. Inspect

If using a generator to power lighting system, refer to applicable generator manual safety information section.

for cuts in the insulation

never grab or touch a live power

cord or cable with wet hands. The possibility exists of electrical shock, electrocution or death.

Make sure power cables are securely connected.

Incorrect connections may cause electrical shock and damage to the lighting system.

NOTICE

ALWAYS make certain that proper power or extension

cord has been selected for the job. See Cable Selection Chart in this manual.

Page 11 of the Multiquip GBC user manual — NOTICE
Page 11 · click to enlarge
Page 11

Safety Information

loading and unloading

Cart type - no lifi ting hook

Cart type - With lifi ting hook

If lighting system is not equipped with a transport lifting hook and the mast is removable, refer to the following safety information.

If lighting system is equipped with a transport lifting hook, refer to the following safety information.

Before lifting, make sure that the mast and lamp are

removed as described in the manual.

Before lifting, make sure that lighting system parts are

The cart can be safely lifted by two persons to the

not damaged and screws are not loosened or lost.

transport vehicle.

ALWAYS make sure crane or lifting device has been

transporting saFety

properly secured to lifting hook of the equipment.

NOTICE

never lift the equipment while lighting system is

running.

When transporting the lighting system, if applicable,

always place in stow position and place mast in its carrying case.

Make sure the mast is completely lowered before lifting

the lighting system.

ALWAYS remove balloon/lamp assembly from the mast

Use adequate lifting cable (wire or rope) of suffi cient

when transporting lighting system. This will prevent damage to the bulb due to vibration.

strength.

Use one point suspension hook and lift straight upwards.

never leave the balloon/lamp exposed during transport.

Exposure to excess wind or rain could damage the balloon’s nylon cover.

Multiquip GBC — NOTICE diagram (page 11)
Fig. 10

ALWAYS place balloon inside its protective cover during

transport. Be sure the cover is secured tightly around the balloon/lamp assembly.

Never allow any person or animal to stand underneath the

equipment while lifting.

do not lift machine to unnecessary heights.

Page 12 of the Multiquip GBC user manual — Specifications
Page 12 · click to enlarge
Page 12

Specifications

Table 1. Specifications ModelGBC Input Voltage90-130, 170-240 VAC Max. Current9.3 A @ 120 V Frequency50-60 Hz Single-Phase Lamp Type1,000 Watt Metal Halide Total Luminous Flux99,750 lm Standard Balloon Diameter47.2 in (1200 mm) Light Coverage (360°)150 ft (45.7 meters) Lamp Surface Temperature (Longitudinal)476.6° F (247° C) max Lamp Surface Temperature (Transversal)417.2° F (214° C) max Balloon Dimensions (L x W x H)47.2 x 47.2 x 28.3 in. (1200 x 1200 x 720 mm) Balloon MaterialPolyester Balloon Heat-Resisting Temperature320-356° F (160-180° C) Internal Balloon Temperature126° F (52° C) Balloon Water Resistance1,500 mm H O 2 Fan Motor Voltage24 VDC Fan Motor Current1.2 A Fan Motor Pressure0.324 kPA (0.047 psi) Outriggers3 Mast - Number of Stages3 (air shock absorbers) Dimensions (L x W x H) Upper Working Position51.2 x 52.2 x 73.6 to 126 in (1,300 x 1,325 x 1,870 to 3,200 mm) Dimensions (L x W x H) Storage27.6 x 40 x 47.7 in (700 x 1,023 x 1,212 mm) Weight133.4 lb (49.8 kg) Appropriate Generator1700 Watts
Page 13 of the Multiquip GBC user manual — G
Page 13 · click to enlarge
Page 13

dimensions

G

D

E

A

F

B

Figure 1. GBC Dimensions

Table 2. Dimensions Reference Letter Description Dimension inches (mm) A Cart Width 27.6 (700) B Cart Length 40.3 (1,023) C Total Max. Height (with Standard Balloon) 127.3 (3,200) D Standard Balloon Height 25.6 (650) E Mast Height (without Balloon) 100.1 (2,543) F Cart Height 12.2 (310) G Standard Balloon Diameter 47.2 (1,200)

Page 14 of the Multiquip GBC user manual — footcandle plot
Page 14 · click to enlarge
Page 14

footcandle plot

VALUES LISTED AS FOOTCANDLES SCALE1 GRID = 50 FT. (15.24 METERS)

Figure 2. Illumination Range

Page 15 of the Multiquip GBC user manual — general information
Page 15 · click to enlarge
Page 15

general information

The Multiquip GBC Lighting System is a general purpose floodlight tower intended for emergency and remote lighting needs. It is universally adaptable to all AC power supplies and accepts 50/60 Hz, 100-240 V.

The GBC uses a single 1,000 watt lamp with pure white light for maximum illumination with a light coverage of up to 150 feet. The standard balloon (GBP) that comes with the GBC provides 360° glarefree illumination. The balloon is self-inflating and easy to install and inflate in less than 20 seconds.

The GBC has a three-stage mast that extends to a height of up to 12 feet. It has a steerable cart design for easy transportation. Three outriggers on the cart ensures great stabilization.

The GBC can be powered by a variety of Multiquip's series generators with an output power of 1.7 kW or greater.

If an extension cord is necessary to connect to a power source, refer to Table 3 to select the proper length.

Table 3. Extension Cord Gauge Selection

Multiquip GBC — general information diagram (page 15)
Fig. 11 · general information

Volts Length of Cord in Feet 115V 25 Ft. 50 Ft. 100 Ft. 150 Ft. 200 Ft. 250 Ft. 300 Ft. 400 Ft. 500 Ft. 230V 50 Ft. 100 Ft. 200 Ft. 300 Ft. 400 Ft. 500 Ft. 600 Ft. 800 Ft. 1000 Ft. 0 - 2 18 18 18 16 16 14 14 12 12 2 - 3 18 18 16 14 14 12 12 10 10 3 - 4 18 18 16 14 12 12 10 10 8 4 - 5 18 18 14 12 12 10 10 8 8 5 - 6 18 16 14 12 10 10 8 8 6 6 - 8 18 16 12 10 10 8 6 6 6 8 - 10 18 14 12 10 8 8 6 6 4 10 - 12 16 14 10 8 8 6 6 4 4 12 - 14 16 12 10 8 6 6 6 4 2 14 - 16 16 12 10 8 6 6 4 4 2 16 - 18 14 12 8 8 6 4 4 2 2 18 - 20 14 12 8 6 6 4 4 2 2

Page 16 of the Multiquip GBC user manual — 10 12 13
Page 16 · click to enlarge
Page 16

components

10 12 13

Figure 3. GBC Components

Page 17 of the Multiquip GBC user manual — WARNING
Page 17 · click to enlarge
Page 17

components

Figure 3 shows the location of the controls and components for the GBC Lighting System. The functions of each control is described below:

14. T-Handle — Moves the GBC in either forward or reverse direction by pulling back or pushing forward. The T-handle also allows the cart to be steered left or right.
1. Balloon Cover — Stores balloon when GBC is not in use. Allow a sufficient amount of time for the lamp to cool down before storing balloon. Possibility exists of balloon getting burned.
15. Mast — This mast is comprised of three separate stages. The mast can be raised in excess of 8 feet (without balloon).
2. Balloon — Made of heat resistant polyester, with a diameter of 47.2 inches (1,200 mm). Balloon is selfinflating and inflates in less than 20 seconds.

WARNING

When raising the mast, always be on the lookout for overhead obstructions.

3. Velcro — Used to easily attach optional message strip to the balloon.
16. Mast Bolt — Loosen to raise mast and tighten to keep the mast in place when raised to the desired height.
4. Buckle — Used to hold the balloon together when storing inside the cover.
17. Message Strip (OPTIONAL) — A 12 x 43 inch message strip (Part No. GBBALD1) may be attached to the balloon. The message strip can be purchased separately.
5. AC Power Cable — Connects to the AC power source.
6. Cart — Holds the generator and can be steered easily to transport GBC to different locations .
18. Zipper — Zips up balloon to completely close it when lamp is in place.
7. Locking Clamps — To secure the generator to the cart platform, place clamps around the pipe frame of the generator. Tighten securely to prevent movement.
19. Lamp Holder — Holds lamp in place. Lamp is screwed into socket.
8. Tire — The GBC uses four pneumatic tires for easy maneuverability.
20. Lamp/Balloon Bolt — Used to tighten mast when attached to the lamp/balloon assembly.
9. Brake Pad — When the brake pedal is pressed, this pad will strike and hold the rear tires in place.
21. Fan Motor (Blower) — Inflates the balloon as soon as power is applied to the GBC.
10. Strap Slots — Allows suitcase generators to be strapped to cart securely.
22. Lamp — 1000 watt metal halide bulb with pure white light for maximum illumination.
11. Outriggers — Provides stability to the GBC. When raising the mast, outriggers should always be deployed.
23. Lamp Guard — Protects the lamp from being hit by objects and balloon material from touching lamp.
12. Counter Weight — Locks the outriggers in place when they are deployed or stowed.
13. Brake Pedal — Step on this pedal and pull back T-handle to apply the brakes. To release the brakes, press down and hold brake pedal again then release.
Page 18 of the Multiquip GBC user manual — BALLOON
Page 18 · click to enlarge
Page 18

setup

1. Set the GBC cart on a firm level surface where there is enough space around the cart for the outriggers to be deployed.
5. Insert the balloon assembly into the mast. Tighten the T-bolt securely. See Figure 7.
2. Insert the T-handle into the handle holder on the cart. Tighten with the wing bolt. See Figure 4.
Multiquip GBC — setup diagram (page 18)
Fig. 12 · setup

BALLOON PROTECTIVE COVER

T-HANDLE

T-BOLT

MAST

Figure 7. Installing the Balloon

6. Unsnap the three buttons on the bottom of the balloon cover and unzip the cover. See Figure 8.

WING BOLT

Multiquip GBC — WING BOLT diagram (page 18)
Fig. 13

ZIPPER

Figure 4. T-Handle Installation

3. Insert the mast into the mast holder and secure with lever as shown in Figure 5.
Multiquip GBC — ZIPPER diagram (page 18)
Fig. 14

BUTTON

Figure 8. Unzipping Balloon Cover

7. Fold the balloon cover into itself and zip it up. See Figure 9.

FOLD PROTECTIVE COVER INTO ITSELF

Figure 5. Inserting the Mast Into Holder

ZIPPER

4. If desired, attach an optional extension pole to the top of the mast as shown in Figure 6.

BALLOON

FULLY EXPOSED

EXTENSION POLE

BOLT

Figure 9. Folding Balloon Cover

Figure 6. Extension Pole Attachment

Page 19 of the Multiquip GBC user manual — BUCKLE
Page 19 · click to enlarge
Page 19

setup

8. Secure the power cable by hooking it to the eyelet on the bottom of the balloon as shown in Figure 10.

CABLE HOOK

Figure 10. Securing Cable with Hook

9. Release the buckle on the belt holding the balloon together. See Figure 11.

BUCKLE

Figure 11. Releasing Buckle

Page 20 of the Multiquip GBC user manual — releasing PARKING BRAKE
Page 20 · click to enlarge
Page 20

operation

APPLYING PARKING BRAKE

deploying outrigger

1. Step on the brake pedal while pulling on the T-handle until the brake pedal is all the way down. See Figure 12.
1. Pull up the counterweight that holds the outrigger in place and pull the outrigger all the way out. See Figure 14.
Multiquip GBC — APPLYING PARKING BRAKE diagram (page 20)
Fig. 15
Multiquip GBC — APPLYING PARKING BRAKE diagram (page 20)
Fig. 16

Figure 12. Applying Brake

Figure 14. Deploying Outrigger

releasing PARKING BRAKE

2. Pull the outrigger down until it touches the ground. Pull down counterweight to lock the outrigger in place. See Figure 15.
1. Step on the brake pedal, hold then release. See Figure 13. This will disengage the braking mechanism and will allow the GBC to be moved.
Multiquip GBC — releasing PARKING BRAKE diagram (page 20)
Fig. 17 · releasing PARKING BRAKE
Multiquip GBC — releasing PARKING BRAKE diagram (page 20)
Fig. 18 · releasing PARKING BRAKE

Figure 15. Locking Deployed Outrigger

Figure 13. Releasing Brake

Page 21 of the Multiquip GBC user manual — STOWING OUTRIGGER
Page 21 · click to enlarge
Page 21

operation

STOWING OUTRIGGER

raising the mast

1. Pull up the counterweight to unlock the outrigger and pull up outrigger. See Figure 16.
Multiquip GBC — STOWING OUTRIGGER diagram (page 21)
Fig. 19

ALWAYS make sure the area above the lighting system is open and clear of overhead power lines and other obstructions. Contact with overhead power lines or other obstructions could result in equipment damage, electrical shock, electrocution and even death.

Multiquip GBC — STOWING OUTRIGGER diagram (page 21)
Fig. 20

When raising or lowering the mast, keep hands and fingers clear of the mast sections to prevent hand and fingers from getting pinched.

Figure 16. Stowing Outrigger

1. Raise the second mast to the desired height and tighten the T-bolt securely. See Figure 18.
2. Push in outrigger until it is all the way in and pull down counterweight to lock it in place. See Figure 17.
Multiquip GBC — STOWING OUTRIGGER diagram (page 21)
Fig. 21
Multiquip GBC — STOWING OUTRIGGER diagram (page 21)
Fig. 22

Figure 18. Raising the Second Mast

2. To raise the mast higher, raise the third mast until the lock/release tab pops out. The tab will automatically rest on the second mast. See Figure 19.

Figure 17. Locking Stowed Outrigger

Multiquip GBC — STOWING OUTRIGGER diagram (page 21)
Fig. 23

Figure 19. Raising the Third Mast

Page 22 of the Multiquip GBC user manual — DIMMER
Page 22 · click to enlarge
Page 22

operation

LOWERING THE MAST

2. Connect the AC power cable to the 120 VAC receptacle on the generator used. See Figure 23.
1. Loosen the T-bolt holding the second mast and push mast all the way down. Tighten T-bolt securely. See Figure 20.
Multiquip GBC — LOWERING THE MAST diagram (page 22)
Fig. 24

TYPICAL GENERATOR FRONT PANEL

Multiquip GBC — TYPICAL GENERATOR FRONT PANEL diagram (page 22)
Fig. 25

Figure 23. Connecting to Power Source

3. Start the generator as indicated in the generator manual.

Figure 20. Lowering Second Mast

4. Turn on the Power ON/OFF switch (Figure 22). The balloon will start to inflate and the lamp will turn on.
2. Push the lock/release tab on the third mast to release it and lower third mast. See Figure 21.

DIMMING THE LAMP

Multiquip GBC — DIMMING THE LAMP diagram (page 22)
Fig. 26
1. Slightly unzip the bottom of the balloon to gain access to the dimmer switch (Figure 24).
Multiquip GBC — DIMMING THE LAMP diagram (page 22)
Fig. 27

Figure 21. Lowering Third Mast

APPLYING POWER

1. Before applying power, make sure that the Power ON/OFF switch (Figure 22) is in the OFF position.

ZIPPER

Figure 24. Unzipping Balloon

2. Press the dimmer switch lightly (Figure 25). The LED will blink. The lamp should dim to about 75% brightness.
Multiquip GBC — ZIPPER diagram (page 22)
Fig. 28

DIMMER

SWITCH

Figure 22. ON/OFF Switch

Figure 25. Dimmer Switch

Page 23 of the Multiquip GBC user manual — SHUTDOWN
Page 23 · click to enlarge
Page 23

operation

3. To turn back the lamp to its original brightness, press the dimmer switch again. The LED will turn off.

STORAGE

Before storing the GBC Lighting System, perform the following steps.

4. Tor turn off the lamp while keeping the balloon inflated, press and hold the dimmer switch for three seconds. The LED will light red.

NOTICE

5. Zip up the bottom of the balloon completely after use of the dimmer switch.

Allow about 15 to 20 minutes for the lamp to cool down before storing the GBC. The possibility exists of the balloon getting burned if it touches a hot lamp.

NOTICE

To turn on lamp again, after it was turned off with the dimmer switch, turn off the Power ON/OFF switch. Wait three to five minutes then turn the ON/OFF switch back on. The lamp will now light back to 100% brightness.

1. Disconnect the lamp connector from the AC power cable.
2. Make sure the mast is completely lowered as described in LOWERING THE MAST section.

NOTICE

3. Unhook the AC power cable from the eyelet at the bottom of the balloon.

If the power cable is accidentally unplugged from the power source, wait three to five minutes before reconnecting the power. This will allow time for the fan to reset and ensure balloon will inflate properly when power is reconnected.

4. Lock the buckle to secure the balloon together.
5. Unzip the zipper on the protective cover and pull down cover over the balloon/lamp assembly.
6. Attach velcro tabs.

SHUTDOWN

7. Loosen the T-bolt on the balloon/lamp assembly and lift balloon/lamp assembly from the mast.
1. Turn off the power switch of the generator.
2. Turn off the Power ON/OFF switch. The balloon should start to deflate and the lamp will turn off.
8. Release the lever on the mast holder and pull out the mast.
3. Disconnect the AC power cable from the generator.
9. Stow the three outriggers as detailed in the STOWING OUTRIGGER section.
Page 24 of the Multiquip GBC user manual — LAMP
Page 24 · click to enlarge
Page 24

maintenance

REPLACING LAMP

3. Remove the lamp guard (Figure 28).
Multiquip GBC — REPLACING LAMP diagram (page 24)
Fig. 29
Multiquip GBC — REPLACING LAMP diagram (page 24)
Fig. 30

Never attempt to replace lamp in a wet place. The possibility exists of electric shock.

LAMP HOLDER

Always allow sufficient time for the lamp to cool down before replacing. The possibility exists of severe burns if hot lamp is touched.

LAMP GUARD

Figure 28. Lamp Guard Removal

4. Press tabs on the lamp holder and lift up holder to release lamp. Remove the lamp from the lamp socket by turning lamp counterclockwise. See Figure 29.

Always shutdown power source and remove balloon assembly from mast when replacing a broken lamp. Utmost care should be taken in handling broken lamp. The possibility exists of serious injury from handling a broken lamp.

Multiquip GBC — LAMP GUARD diagram (page 24)
Fig. 31
1. Unzip the zipper at the bottom of the balloon and roll the balloon up to expose the lamp. See Figure 26.

LAMP

Multiquip GBC — LAMP diagram (page 24)
Fig. 32

SOCKET

BALLOON ENVELOPE

Figure 29. Removing Lamp

ZIPPER

5. Install new lamp into socket and turn lamp in a clockwise direction until tight. See Figure 30. Press tabs on the lamp holder and slowly bring down the holder to secure lamp in place.

Figure 26. Exposing Balloon

Multiquip GBC — ZIPPER diagram (page 24)
Fig. 33
2. Release the lamp guard locking tabs. See Figure 27.
Multiquip GBC — ZIPPER diagram (page 24)
Fig. 34

LAMP

LAMP GUARD

SOCKET

Figure 30. Installing New Lamp

Figure 27. Removing Lamp Guard

Page 25 of the Multiquip GBC user manual — maintenance
Page 25 · click to enlarge
Page 25

maintenance

Multiquip GBC — maintenance diagram (page 25)
Fig. 35 · maintenance
3. Slide in the new replacement balloon over the top of the lamp guard assembly. See Figure 33.

Do not use excessive force when screwing the lamp to prevent lamp from breaking.

7. Pull down balloon and zip the bottom zipper to cover lamp.
1. Unzip the top and bottom of the balloon. See Figure 31.
4. Zip up the top and bottom of the new balloon. See Figure 34.
2. Slide out the old or worn balloon over the top of the lamp guard assembly. See Figure 32.

Figure 32. Removing Old Balloon

Page 26 of the Multiquip GBC user manual — AIR PLATE
Page 26 · click to enlarge
Page 26

maintenance

filter replacement

5. Install a new filter and reinstall the air plate.
1. Remove the balloon as described in the STORAGE section.
6. Turn the three locking tabs inwards to lock the air plate in place. See Figure 37.
2. Turn the balloon/lamp assembly upsidedown to access the filter. See Figure 35.

LOCK TAB

AIR PLATE

LOCKING TAB

Figure 37. Locking Air Plate

Figure 35. Accessing Filter

3. Turn the three locking tabs outwards to release the air plate. See Figure 35.
4. Remove the air plate and filter. See Figure 36.

AIR PLATE

FILTER

Figure 36. Filter Removal

Page 27 of the Multiquip GBC user manual — maintenance
Page 27 · click to enlarge
Page 27

maintenance

Table 4. Troubleshooting SYMPTOM POSSIBLE PROBLEM SOLUTION

Is plug disconnected? Plug in correctly. Is generator power switched off? Turn on switch. Is lamp loose? Screw lamp securely into socket. Is power connector disconnected or loose? Connect disconnected connector.

Are any other electric appliances (other than light tower) plugged into power source?

Lamp does not light.

Unplug all other appliances.

Is model of lamp incompatible? Use genuine MQ lamp. Is lamp not cool enough to light again? (Interval of 5 to 10 minutes is required before turning on lamp again)

Wait for lamp to cool down.

Lamp only lights for a short time. Is ambient temperature too high (more than 104° F (40° C)?

Move lamp where there is proper ventilation.

Is fan motor (blower) not working properly? Check and repair fan motor (blower).

Balloon does not inflate.

Is balloon envelope defective? Repair or replace balloon envelope.

Page 28 of the Multiquip GBC user manual — maintenance
Page 28 · click to enlarge
Page 28

maintenance

B2

B1

M1

B3

E1

M2

B4

C11 C3 C2

E2

Figure 38. Maintenance Check Points

Page 29 of the Multiquip GBC user manual — maintenance
Page 29 · click to enlarge
Page 29

maintenance

Table 5. Periodic Check and Maintenance FIGURE PART CHECK ITEM SOLUTION

  • L1 Lamp (Base) Lamp base loose? Screw in securely.
  • L2 Lamp Holder Lamp holder loose? Replace. # L3 Pipe Frame Pipe Frame skewed? Replace. & L4 Lamp Defective lamp? Replace.
  • B1 Balloon (Envelope) Defective or dirty? Replace.
  • B2 Zipper Broken? Replace.
  • B3 Fan Motor (Blower) Not working properly? Repair or replace. $ B4 T-handle bolt (balloon) Broken? Replace.

C1 Outrigger Movement not smooth? Spray grease. $ C2 T-handle and wheels Improper movement? Tighten securely. $ C3 Bolt for handle Bolt loose? Tighten securely. $

  • C4 Brake pedal Linkage not working correctly? Check, spray grease.
  • Notch worn-out? Replace.
  • C5 Stopper Damaged? Replace. # C6 Front wheel pivot Does not turn smoothly? Check, spray grease. $ C7 Tires Tire pressure not 35.5 psi (294 kPa)? Adjust.
  • C8 Link for front shaft Linkage not working correctly? Spray grease. $ C9 Brake Not working properly? Adjust.
  • C10 Lever Lever loose? Tighten securely.
  • C11 Counterweight (Outrigger) Does not work smoothly? Spray grease.
  • Electric E1 Power cable Defective or worn cable? Replace.
  • E2 Plug Damaged? Replace. #
  • — Check daily # — Every 20 hours $ — Every 100 hours & — Every 500 hours

Lamp · Balloon · Cart

Page 30 of the Multiquip GBC user manual — wiring diagram
Page 30 · click to enlarge
Page 30

wiring diagram

Multiquip GBC — wiring diagram diagram (page 30)
Fig. 36 · wiring diagram
Page 31 of the Multiquip GBC user manual — notes
Page 31 · click to enlarge
Page 31

notes

Page 32 of the Multiquip GBC user manual — “XXXXX ONLY” “NOT USED ON XXXX”
Page 32 · click to enlarge
Page 32

Explanation of Code in Remarks Column

The following section explains the different symbols and remarks used in the Parts section of this manual. Use the help numbers found on the back page of the manual if there are any questions.

Qty. Column

numbers used — Item quantity can be indicated by a number, a blank entry, or A/R.

NOTICE

A/R (As Required) is generally used for hoses or other parts that are sold in bulk and cut to length.

The contents and part numbers listed in the parts section are subject to change without notice. Multiquip does not guarantee the availability of the parts listed.

A blank entry generally indicates that the item is not sold separately. Other entries will be clarifi ed in the “Remarks” Column.

sample parts list

remarKs Column

no. part no. part name Qty. remarKs 1 12345 BOLT 1 INCLUDES ITEMS W/% 2% WASHER, 1/4 IN NOT SOLD SEPARATELY 2% 12347 WASHER, 3/8 IN. ..1 MQ-45T ONLY 3 12348 HOSE A/R ...MAKE LOCALLY 4 12349 BEARING 1 S/N 2345B AND ABOVE

Some of the most common notes found in the “Remarks” Column are listed below. Other additional notes needed to describe the item can also be shown.

assembly/Kit — All items on the parts list with the same unique symbol will be included when this item is purchased.

no. Column

Indicated by:

unique symbols — All items with same unique symbol

“INCLUDES ITEMS W/(unique symbol)”

(@, #, +, %, or >) in the number column belong to the same assembly or kit, which is indicated by a note in the “Remarks” column.

serial number Break — Used to list an effective serial number range where a particular part is used.

Indicated by:

duplicate item numbers — Duplicate numbers indicate multiple part numbers, which are in effect for the same general item, such as different size saw blade guards in use or a part that has been updated on newer versions of the same machine.

“S/N XXXXX AND BELOW” “S/N XXXX AND ABOVE” “S/N XXXX TO S/N XXX”

specifi c model number use — Indicates that the part is used only with the specifi c model number or model number variant listed. It can also be used to show a part is NOT used on a specifi c model or model number variant.

NOTICE

When ordering a part that has more than one item number listed, check the remarks column for help in determining the proper part to order.

Indicated by:

“XXXXX ONLY” “NOT USED ON XXXX”

part no. Column

numbers used — Part numbers can be indicated by a number, a blank entry, or TBD.

“make/obtain locally” — Indicates that the part can be purchased at any hardware shop or made out of available items. Examples include battery cables, shims, and certain washers and nuts.

TBD (To Be Determined) is generally used to show a part that has not been assigned a formal part number at the time of publication.

“not sold separately” — Indicates that an item cannot be purchased as a separate item and is either part of an assembly/kit that can be purchased, or is not available for sale through Multiquip.

A blank entry generally indicates that the item is not sold separately or is not sold by Multiquip. Other entries will be clarifi ed in the “Remarks” Column.

Page 33 of the Multiquip GBC user manual — NOTICE
Page 33 · click to enlarge
Page 33

Suggested Spare Parts

GBC lIGHTING SYSTEM

1 to 3 units

Qty. P/N Description 2 E000080700 LAMP 2 A300168900 E BALLAST ASSY 2 GBB115DR BALLOON CLOTH CP 3 2214500430 FILTER

NOTICE

Part numbers on this Suggested Spare Parts list may supersede/replace the part numbers shown in the following parts lists.

Page 34 of the Multiquip GBC user manual — nameplate and decals
Page 34 · click to enlarge
Page 34

nameplate and decals

Multiquip GBC — nameplate and decals diagram (page 34)
Fig. 37 · nameplate and decals
Page 35 of the Multiquip GBC user manual — nameplate and decals
Page 35 · click to enlarge
Page 35

nameplate and decals

NO. PART NO. PART NAME QTY. REMARKS 1 A400324800 DECAL; GLOBUG INFORMATION 1 2 A400324500 DECAL; RELEASE 3 3 A400324000 DECAL; WARNING, PARKING BRAKE 1 4 A400324600 DECAL; PULL 3 5 A400290900 DECAL; CAUTION, LAMP INFORMATION (ENGLISH) 1 6 A400324200 DECAL; CAUTION, LAMP INFORMATION (FRENCH) 1 7 A400324900 DECAL; LAMP OFF SWITCH 1 8 A400325100 DECAL; ELECTRIC SHOCK, HIGH VOLTAGE, BURN HAZ. 1 9 A400326400 DECAL; LAMP TYPE 1 10 A400325000 DECAL; CAUTION, AC ONLY 1 11 A400206500 DECAL; DIMMER SWITCH 1 12 A400084300 DECAL; GROUND 2 13 A400207401 DECAL; GBC-003 1 14 A400324700 DECAL; WARNING, OUTRIGGER DEPLOYMENT 1 15 A400194900 DECAL; GLOBUG LIGHTING SYSTEM 1 16 A400193300 DECAL; GLOBUG LIGHTING SYSTEM 1 17 NAMEPLATE 1 CONTACT MQ PARTS

Page 36 of the Multiquip GBC user manual — balloon and lamp assy
Page 36 · click to enlarge
Page 36

balloon and lamp assy

Multiquip GBC — balloon and lamp assy diagram (page 36)
Fig. 38 · balloon and lamp assy
Page 37 of the Multiquip GBC user manual — balloon and lamp assy
Page 37 · click to enlarge
Page 37

balloon and lamp assy

NO. PART NO. PART NAME QTY. REMARKS 1# E000125600 LAMP MH1000 1 2# E000038200 RUBBER 1 3# A300273200 SOCKET ASSY 1 4# 0023304015 SCREW AND WASHER, M4X15 2 5# A300160602 PLATE, LAMP 1 6# A400195200 STOPPER 4 7# 0024304004 SCREW, M4x4 8 8# 0023405012 SCREW, M5x12 4 9# A300174000 LAMP HOLDER 1 10# A200057703 MAIN POLE 1 3 11# A200061300 MAIN POLE 2 1 12# 2214500230 SEAL, FLAT 2 13# A100061200 SHEET, TOP 1 14# A100060900 RED BALLOON COVER 1 15# 0014808025 BUTTON SCREW & WASHER, M8x25 4 16# A300162400 SEAL, PACKING 2 17# A300165100 PLATE, TOP 1 18# A300264500 FAN MOTOR ASSY 1 19# 0023304012 SCREW & WASHER, M4x12 12 20# 0023204006 SCREW, M4x6 3 21# A300164900 PLATE, FAN 1 22# 0024304008 SCREW, M4x8 15 23 A400199500 PACKING, LAMP 4 24 0043104000 WASHER, M4 4 25# 0033104000 NUT, M4 9 26# A300145801 BOTTOM PLATE 1 27# A400030700 STOPPER, FILTER 3 28# E000077500 SPACER 3 29# E000009701 WAVE WASHER, M5 3 30# A200057603 FLANGE 1 31# E000070000 SUPPORT NUT 4 32# A300181901 POWER CABLE 1 33# A300269600 SWITCH 1 34# A300160003 COVER 1 1 35# A300160100 COVER 2 1 36# A300165001 PLATE, GUARD 1 37# A100061000 SHEET, BOTTOM 1 38# 0014710035 BUTTON SCREW, M10x35 4 39# 0043210000 SPRING WASHER, M10 4 40# 2204510110 WASHER 1 41# 0043110000 WASHER, M10 3 42# A100061300 LAMP GUARD 1 43# A400209801 KNOB 1 44# A300174401 FILTER 1 45# A300175300 PLATE, AIR 1 46# GBB115DR BALLOON CLOTH 1 CONTACT MQ UNIT SALES 47# GBBALD1 BLANK MESSAGE STRIP (OPTIONAL) 1 CONTACT MQ UNIT SALES 48# A300275900 E BALLAST ASSY 1 49 GBP BALLOON/LAMP ASSY 1 INCLUDES ITEMS W/ # CONTACT MQ UNIT SALES 50 GB48 BALLOON CLOTH (OPTIONAL) 1 CONTACT MQ UNIT SALES 51 GB48BMS BLANK MESSAGE STRIP, 48"X48" (OPTIONAL) 1 CONTACT MQ UNIT SALES 52 GB36 BALLOON CLOTH (OPTIONAL) 1 CONTACT MQ UNIT SALES 53 GB36BMS BLANK MESSAGE STRIP, 36" X 36" (OPTIONAL) 1 CONTACT MQ UNIT SALES 54 GB36N BALLOON CLOTH (OPTIONAL) 1 CONTACT MQ UNIT SALES 55 1654000230 BALLOON PATCH KIT (OPTIONAL) 1 CONTACT MQ UNIT SALES

Page 38 of the Multiquip GBC user manual — MAST assy
Page 38 · click to enlarge
Page 38

MAST assy

Multiquip GBC — MAST assy diagram (page 38)
Fig. 39 · MAST assy
Page 39 of the Multiquip GBC user manual — MAST assy
Page 39 · click to enlarge
Page 39

MAST assy

NO. PART NO. PART NAME QTY. REMARKS 1 A300175400 FIRST MAST 1 2 A300175500 SECOND MAST 1 3 A300175600 THIRD MAST 1 4 A400199700 PLUG 1 5 A400112700 LEAF VALVE 1 6 0023104008 SCREW, M4x8 1 7 0043104000 WASHER, M4 1 8 0023105008 SCREW, M5x8 2 9 0043105000 WASHER, M5 1 10 A400187600 KNOB 2 11 0013108020 BOLT, M8x20 1 12 A400200500 WASHER 1 13 A400110200 WASHER, MAST 2 14 A400200700 RUBBER, MAST 1 15 A400092801 WASHER 2 16 A400200800 BOTTOM PLATE 1 17 0024705008 SET SCREW, M5x8 6 18 E000081200 O-RING 1 19 A400202700 BOLT 1 20 0043108000 WASHER, M8 1 21 A400109600 RUBBER, MAST 1 22 A400092402 BOTTOM PLATE 1 23 A400200300 PIPE, LEVER 1 24 A400200400 WASHER 1 25 A400200201 LEVER, HOOK 1 26 A400195700 SPRING, HOOK 1

Page 40 of the Multiquip GBC user manual — BASE assy
Page 40 · click to enlarge
Page 40

BASE assy

19 14 13 12 15

16 17 18

Page 41 of the Multiquip GBC user manual — BASE assy
Page 41 · click to enlarge
Page 41

BASE assy

NO. PART NO. PART NAME QTY. REMARKS 1 A100064700 BASE PLATE 1 2 A300147201 FRONT SHAFT (L) 1 3 A300147301 FRONT SHAFT (R) 1 4 A300056800 LINK, FRONT SHAFT 1 5 0053512000 PIN 4 6 0043112000 WASHER, M12 4 7 1504120130 WASHER 4 8 0040720000 SNAP RING 8 9 A300137101 STEERING LINK 1 10 A300150900 BRAKE SHAFT 1 11 1521120131 BOLT, M12x75 LEFT SCREW 1 12 2071214010 BRAKE 2 13 A400189601 SPACER, BRAKE 2 14 1503180130 SLEEVE BEARING,18DX20Dx20 2 15 0013212075 BOLT, M12x75 1 16 0010308030 BOLT, M8x30 1 17 2001200313 BRAKE PEDAL 1 18 0043108000 WASHER, M8 1 19 0033108000 NUT, M8 2 20 1041000131 SPRING, BRAKE 1 21 1503300130 SLEEVE BEARING, 30DX34Dx20 2 22 0040730000 SNAP RING 1 23 A200023001 HANDLE 1 INCLUDES ITEM W/ # 24# 1102700130 HANDLE GRIP 2 25 A400176500 LINK, HANDLE 1 26 0014212025 WING BOLT, M12x25 1 27 0043112041 WASHER, 12DX40DX3.2T 1 28 E000014500 TIRE ASSY, 4.10/3.505 4 29 1652000430 CAP 2

Page 42 of the Multiquip GBC user manual — OUTRIGGER assy
Page 42 · click to enlarge
Page 42

OUTRIGGER assy

Page 43 of the Multiquip GBC user manual — OUTRIGGER assy
Page 43 · click to enlarge
Page 43

OUTRIGGER assy

NO. PART NO. PART NAME QTY. REMARKS 1 A300162202 OUTRIGGER 3 2 1641001430 RUBBER FOOT 3 3 A400175302 HOLDER, OUT, R 3 4 A400176901 LEVER, OUT, R 3 5 A400114401 WASHER 3 6 A300147802 WEIGHT, OUT, R 3 7 0033210000 SELF LOCK NUT, M10 3 8 0053304025 SPRING PIN, M4x25 3 9 0013112030 BOLT, M12x30 3 10 0043110000 WASHER, M10 3 11 0033212000 SELF LOCK NUT, M12 3 12 0043112000 WASHER, M12 3 13 0033206000 SELF LOCK NUT, M6 1 14 A400166400 LOCKING CLAMP 4 15 0013510025 BOLT AND WASHER, M10x25 4 16 2212780310 LEVER 1 17 0043108000 WASHER, M8 1

Page 44 of the Multiquip GBC user manual — Terms and Conditions of Sale — Parts
Page 44 · click to enlarge
Page 44

Terms and Conditions of Sale — Parts

5. Parts must be in new and resalable condition, in the original Multiquip package (if any), and with Multiquip part numbers clearly marked.

Multiquip reserves the right to quote and sell direct to Government agencies, and to Original Equipment Manufacturer accounts who use our products as integral parts of their own products.

Terms of payment for parts are net 30 days.

6. The following items are not returnable:

All parts orders will be shipped collect or prepaid with the charges added to the invoice. All shipments are F.O.B. point of origin. Multiquip’s responsibility ceases when a signed manifest has been obtained from the carrier, and any claim for shortage or damage must be settled between the consignee and the carrier.

a. Obsolete parts. (If an item is in the price book and shows as being replaced by another item, it is obsolete.)

A $35.00 surcharge will be added to the invoice for special handling including bus shipments, insured parcel post or in cases where Multiquip must personally deliver the parts to the carrier.

b. Any parts with a limited shelf life (such as gaskets, seals, “O” rings, and other rubber parts) that were purchased more than six months prior to the return date.

limitations oF seller’s liaBility

Multiquip shall not be liable hereunder for damages in excess of the purchase price of the item with respect to which damages are claimed, and in no event shall Multiquip be liable for loss of profi t or good will or for any other special, consequential or incidental damages.

The minimum charge for orders from Multiquip is $15.00 net. Customers will be asked for instructions regarding handling of orders not meeting this requirement.

c. Any line item with an extended dealer net price of less than $5.00.

d. Special order items.

e. Electrical components.

Return shipments will be accepted and credit will be allowed, subject to the following provisions:

f. Paint, chemicals, and lubricants.

g. Decals and paper products.

No warranties, express or implied, are made in connection with the sale of parts or trade accessories nor as to any engine not manufactured by Multiquip. Such warranties made in connection with the sale of new, complete units are made exclusively by a statement of warranty packaged with such units, and Multiquip neither assumes nor authorizes any person to assume for it any other obligation or liability whatever in connection with the sale of its products. Apart from such written statement of warranty, there are no warranties, express, implied or statutory, which extend beyond the description of the products on the face hereof.

h. Items purchased in kits.

1. A Returned Material Authorization must be approved by Multiquip prior to shipment.
7. The sender will be notifi ed of any material received that is not acceptable.
2. To obtain a Return Material Authorization, a list must be provided to Multiquip Parts Sales that defi nes item numbers, quantities, and descriptions of the items to be returned.
8. Such material will be held for five working days from notifi cation, pending instructions. If a reply is not received within five days, the material will be returned to the sender at his expense.

a. The parts numbers and descriptions must match the current parts price list.

9. Credit on returned parts will be issued at dealer net price at time of the original purchase, less a 15% restocking charge.

b. The list must be typed or computer generated.

10. In cases where an item is accepted, for which the original purchase document can not be determined, the price will be based on the list price that was effective twelve months prior to the RMA date.

c. The list must state the reason(s) for the return.

d. The list must reference the sales order(s) or invoice(s) under which the items were originally purchased.

EffectiveFebruary 22, 2006
11. Credit issued will be applied to future purchases only.

e. The list must include the name and phone number of the person requesting the RMA.

Prices are subject to change without prior notice. Price changes are effective on a specifi c date and all orders received on or after that date will be billed at the revised price. Rebates for price declines and added charges for price increases will not be made for stock on hand at the time of any price change.

3. A copy of the Return Material Authorization must accompany the return shipment.
4. Freight is at the sender’s expense. All parts must be returned freight prepaid to Multiquip’s designated receiving point.
Show 7 more labels / short text on this page
payment terms · Freight poliCy · speCial eXpediting serviCe · minimum order · returned goods poliCy · limitation oF Warranties · priCing and reBates
Page 45 of the Multiquip GBC user manual — notes
Page 45 · click to enlarge
Page 45

notes

Page 46 of the Multiquip GBC user manual — PLEASE HAVE THE MODEL AND SERIAL
Page 46 · click to enlarge
Page 46

Operation and Parts Manual

HERE’S HOW TO GET HELP

PLEASE HAVE THE MODEL AND SERIAL

NUMBER ON-HAND WHEN CALLING

Multiquip Corporate Office MQ Parts Department

18910 Wilmington Ave. Carson, CA 90746 Contact: mq@multiquip.com

Tel. (800) 421-1244 Fax (310) 537-3927

800-427-1244 310-537-3700 Fax800-672-7877 Fax: 310-637-3284

Service Department Warranty Department

800-421-1244 310-537-3700 Fax310-537-4259 800-421-1244 310-537-3700 Fax: 310-943-2249
800-478-1244 Fax310-943-2238

MQ Cipsa Multiquip (UK) Limited Head Office

Carr. Fed. Mexico-Puebla KM 126.5 Momoxpan, Cholula, Puebla 72760 Mexico Contact: pmastretta@cipsa.com.mx

Tel(52) 222-225-9900 Fax: (52) 222-285-0420

Unit 2, Northpoint Industrial Estate, Globe Lane, Dukinfield, Cheshire SK16 4UJ Contact: sales@multiquip.co.uk

Tel0161 339 2223 Fax: 0161 339 3226

4110 Industriel Boul. Laval, Quebec, Canada H7L 6V3 Contact: jmartin@multiquip.com

Tel(450) 625-2244 Tel: (877) 963-4411 Fax: (450) 625-8664

© COPYRIGHT 2013, MULTIQUIP INC.

Multiquip Inc, the MQ logo are registered trademarks of Multiquip Inc. and may not be used, reproduced, or altered without written permission. All other trademarks are the property of their respective owners and used with permission.

This manual MUsT accompany the equipment at all times. This manual is considered a permanent part of the equipment and should remain with the unit if resold.

The information and specifications included in this publication were in effect at the time of approval for printing. Illustrations, descriptions, references and technical data contained in this manual are for guidance only and may not be considered as binding. Multiquip Inc. reserves the right to discontinue or change specifications, design or the information published in this publication at any time without notice and without incurring any obligations.

Your Local Dealer is:

Show 5 more labels / short text on this page
United StateS · Technical Assistance · mexico United Kingdom · Canada · Multiquip
Sources

References & links

Pages referenced in this manual — manufacturer, support and downloads.

Ask about the Multiquip GBC

Owners and our team usually reply within a day — and your question helps the next person too.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
No questions yet about the Multiquip GBC

Be the first to ask — other owners or our team will answer.

Original document

Multiquip GBC manual PDF

46 pages·4.8 MB·Light Therapy Device·PDF
Click any page above to open it here
Page 1 / …
100%
Loading pages…