MultiModemII User Guide MT5600BA–V.92, MT5600BA–V.90, MT5600BL–V.90 P/N S000276E Revision E
©2002-2004 by Multi-Tech Systems, Inc.
All rights reserved. This publication may not be reproduced, in whole or in part, without prior expressed written permission from Multi-Tech Systems, Inc.
Multi-Tech Systems, Inc. makes no representations or warranties with respect to the contents hereof and specifically disclaims any implied warranties of merchantability or fitness for any particular purpose. Furthermore, Multi-Tech Systems, Inc. reserves the right to revise this publication and to make changes in the content hereof without obligation of Multi-Tech Systems, Inc. to notify any person or organization of such revisions or changes.
Record of Revisions Revision Date Description
A 10/03/02 Initial release of MT5600BA Global V.92. (Also replaces S0000129 Rev. C - the MT5600BA/BL User Guide).
B 02/17/03 Changed cover. Changed text to indicate that the following are implemented: V.25bis HDLC NRZ?, V.25bis HDLC NRZI?, and V.25bis BISYNC
C 07/31/03 Added setting the country code using the LCD panel. Add country codes list.
D 05/28/04 Change the word to country to country or region.
E 12/09/04 Add Web site location of the country/region code list.
Trademarks MultiModemII, Multi-Tech, and the Multi-Tech logo are trademarks of Multi-Tech Systems, Inc.
Adobe and Acrobat are trademarks of Adobe Systems Incorporated. Microsoft, Windows, Windows 98/ Me/NT/2000/XP are either registered trademarks or trademarks of Microsoft Corporation in the United States and/or other countries. All other brand and product names mentioned in this publication are trademarks or registered trademarks of their respective companies.
Patents This device is covered by one or more of the following patents: 6,031,867; 6,012,113; 6,009,082; 5,905,794; 5,864,560; 5,815,567; 5,815,503; 5,812,534; 5,809,068; 5,790,532; 5,764,628; 5,764,627; 5,754,589; 5,724,356; 5,673,268; 5,673,257; 5,644,594; 5,628,030; 5,619,508; 5,617,423; 5,600,649; 5,592,586; 5,577,041; 5,574,725; 5,559,793; 5,546,448; 5,546,395; 5,535,204; 5,500,859; 5,471,470; 5,463,616; 5,453,986; 5,452,289; 5,450,425; D353,598; 5,355,365; 5,309,562; 5,301,274. Other patents pending.
Multi-Tech Systems, Inc. 2205 Woodale Drive Mounds View, MN 55112 U.S.A
Telephone (763) 785-3500 or (800) 328-9717 Fax (763) 785-9874 Technical Support (800) 972-2439 Internet http://www.multitech.com
World Headquarters


Chapter 1 - Description and Features
Chapter 1 - Descr 1 - Descr 1 - Descr 1 - Descr 1 - Description and n and n and n and n and Features
Congratulations on your purchase of the MultiModemII modem. You have acquired one of the finest intelligent data/fax modems available today from one of the world’s oldest modem manufacturers: Multi- Tech Systems, Inc. This user guide will help you install, configure, test and use your modem. Product Description This modem supports two-wire and/or four-wire leased lines. The four-wire leased line includes the dial backup and automatic leased line restoration features. Please note that, because leased-line operation consists of two client modems connected to each other, the maximum leased line data rate is 33.6K bps.
The MT5600BA-V.92 modem supports both two-wire and four-wire leased lines. The MT5600BA modem supports a two-wire leased line. The MT5600BL modem supports a four-wire leased line. The MultiModemII offers interactive automatic dialing. You can store four command lines or telephone numbers of up to 30 characters each in the modem’s nonvolatile memory. The modem pulse- or tone- dials, and recognizes dial tones and busy signals for reliable call-progress detection. It can also detect AT&T calling card tones. It is FCC-registered for connection to telephone networks without notification to the telephone company. The MultiModemII front panel includes a liquid crystal display and four buttons, which together can be used to either display the current connection status of the modem or to configure the modem. The MultiModemII also can be configured through standard AT commands. About AT Commands
Multi-Tech Systems, Inc. MT5600BA/BL Series User Guide (S000276E)

Chapter 1 - Description and Features
Safety Warnings
Multi-Tech Systems, Inc. MT5600BA/BL Series User Guide (S000276E)

Chapter 2 - Installation
Chapter 2 - Inst 2 - Inst 2 - Inst 2 - Inst 2 - Installation
Turn off your computer. Placing the modem in a convenient location, connect it to your computer’s serial port, to the telephone line, to your leased line, to AC power, and, optionally, to your telephone.
MultiModemII connections with V.92 transformer and V.90 transformer. Connect the Mod he Mod he Mod he Mod he Modem to em to em to em to em to Your PC
Plug one end of the serial cable into the RS-232 connector on the modem, and the other end into a serial port connector on your computer, such as COM1 or COM2.
Connect the Mod he Mod he Mod he Mod he Modem to t em to t em to t em to t em to the Telephone Line ( ne Line ( ne Line ( ne Line ( ne Line (Dialup Connection)
Plug one end of the modular phone cable into the modem’s LINE jack, and the other end into a public switched telephone network (PSTN) wall jack.
Connect theTwo-Wire L e L e L e L e Leased Line ased Line ased Line ased Line ased Line
MT5600BA – Plug one end of a two-wire phone cable into the modem’s LINE jack; connect the other end to a leased line wall jack or terminals.
MT5600BL – Plug one end of a two-wire phone cable into the modem’s LEASED jack; connect the other end to a leased line wall jack or terminals.
Multi-Tech Systems, Inc. MT5600BA/BL Series User Guide (S000276E)
· ·

Chapter 2 - Installation
Connect the F he F he F he F he Four-Wire L e L e L e L e Leased Line ased Line ased Line ased Line ased Line
MT5600BL Only – Plug one end of a four-wire phone cable into the modem's LEASED jack; connect the other end to a four-wire leased line wall jack or terminals.
Modems with a leased-line jack support the dial backup feature. For dial backup operation, plug one end of your dialup modular phone cable into the modem’s LINE jack and the other end into a PSTN wall jack.Plug one end of a two-wire or four-wire phone cable into the modem’s LEASED jack, and connect the other end to a leased-line wall jack or terminals.
Modems with a leased-line jack support the dial backup feature. For dial backup operation, plug one end of your dialup modular phone cable into the modem’s LINE jack and the other end into a PSTN wall jack.
Connect the Pho he Pho he Pho he Pho he Phone to t ne to t ne to t ne to t ne to the Mod he Mod he Mod he Mod he Modem (Opt em (Opt em (Opt em (Opt em (Optional)
For voice-only calls, plug a telephone into the modem’s PHONE jack.
Connect the Mod he Mod he Mod he Mod he Modem to t em to t em to t em to t em to the AC P C P C P C P C Power Outlet
Plug the power transformer into an AC power outlet or power strip. Plug the power transformer’s cable into the POWER jack on the modem. Note: Use only the power transformer supplied with the modem. Use of any other transformer voids the warranty and can damage the modem.
Test the modem by turning it on (a power switch is located on the front panel). When you apply power, the modem performs a diagnostic self-test, indicated by the TM indicator lighting for a few seconds, after which the LCD should light. If this does not happen, check that the power switch is on, the power transformer is solidly connected, and the AC outlet is live. If these measures do not work, see the “Troubleshooting” chapter.
Multi-Tech Systems, Inc. MT5600BA/BL Series User Guide (S000276E)

Chapter 2 - Installation
If you use Windows 98/Me/NT 4.0/2000/XP; you must install the modem driver. The drivers are installed easily since Windows supports Plug-and-Play.
Installing t ling t ling t ling t ling the Mod he Mod he Mod he Mod he Modem Dr em Dr em Dr em Dr em Driver for Windows 98/Me/2000/ s 98/Me/2000/ s 98/Me/2000/ s 98/Me/2000/ s 98/Me/2000/ XP
1. Make sure your modem is connected properly, and then turn on your computer. Windows should detect your new modem and open the Install New Modem wizard. Note: If Windows cannot find a modem, your modem may be turned off, it may be plugged into the wrong connector on your computer, or the serial cable may be faulty. See “None of the LEDs Light When the Modem Is Turned On” and “The Modem Does Not Respond to Commands” in the “Troubleshooting” chapter. 2. Insert the MultiModemII system CD into your CD-ROM drive, and then click OK. 3. Windows installs and configures the modem. 4. Click Finish to exit.
Installing t ling t ling t ling t ling the Mod he Mod he Mod he Mod he Modem Dr em Dr em Dr em Dr em Driver for Windows N s N s N s N s NT
1. Make sure your modem is connected properly, and then turn on your computer. Windows should detect your new modem and open the Install New Modem wizard. Note: If Windows cannot find a modem, your modem may be turned off, it may be plugged into the wrong connector on your computer, or the serial cable may be faulty. See “None of the LEDs Light When the Modem Is Turned On” and “The Modem Does Not Respond to Commands” in the Troubleshooting chapter of the User Guide. 2. In the Install New Modem wizard, select Don’t detect my modem; I will select it from a list, and then click Next. A dialog box with a list of manufacturers and a list of modem models appears. 3. Insert the MultiModemII system CD into your CD-ROM drive, and then click Have Disk. 4. In the Install from Disk dialog box, select the drive that the CD is in, and then click OK. 5. A list of modems appears. Select your modem and click Next. 6. Select the port that the modem is connected to, and then click Next. 7. Windows installs and configures the modem. 8. Click Finish to exit.
Removing an Old Mod ing an Old Mod ing an Old Mod ing an Old Mod ing an Old Modem Dr em Dr em Dr em Dr em Driver
When your new modem replaces another modem, the old modem driver remains in Windows, and the old modem driver is still selected in HyperTerminal and other Windows applications. Though you can change the application connection descriptions one at a time, it is easier to force Windows applications to use the new modem by removing the old modem driver from Windows.
Multi-Tech Systems, Inc. MT5600BA/BL Series User Guide (S000276E)

Chapter 2 - Installation
The MT5600BA-V.92 modem is a global modem - it can be used all over the world. However, countries or regions vary in their requirements for how a modem functions. Therefore, you must configure yours to match the defaults of the country or region in which you are using it. Choose from any of the three methods:
Using t Using t Using t Using t Using the L he L he L he L he LCD P CD P CD P CD P CD Panel
question mark represents the question Is this the region
you want? If B5 is the one you want, press Enter; if it s
not the one you want, arrow across until you see the code
you desire. See the list of Region Codes on the back of this card.
4.When you reach the region code you want, press Enter. After pressing Enter, you will see the message
Option Set.
Region Setting Options B5?
Region Profile 99? Region Profile 01? 02?
Region Profile 03? Region Profile 04?
Region Profile 09? Region Profile 6C? 9F?
Using t Using t Using t Using t Using the Glo he Glo he Glo he Glo he Global Wizard
The Global Wizard configuration utility is recommended for computers running in Windows. The Wizard can configure your modem for a specific country or region with just a few mouse clicks. 1. Insert the MultiModemII CD into the CD-ROM drive. The Autorun dialog box appears. 2. Click Initial Setup and Country or Region Selection. The Global Wizard dialog box appears. Click Next. 3. The Global Wizard searches for your modem and identifies it. Click Next after your modem is identified. 4. Select the country or region in which the modem will be used. Click Next. 5. Review your choice. If it is correct, click Next to configure the modem. 6. When the Global Wizard announces that the parameters have been set, click Finish to exit.
Multi-Tech Systems, Inc. MT5600BA/BL Series User Guide (S000276E)

Chapter 2 - Installation
Using AT Commands
If you are comfortable using AT commands, you can use them to configure your modem. You must enter these commands in your communication program's terminal window. You can use a communication program such as PhoneTools. See Step 4 below.
How to Change the Country/Region Code
How to Verify the Code
Data communications software gives you access to commands that govern how the modem operates; that is, how the modem handles incoming and outgoing data streams, etc. MultiTech includes a data communications software package (PhoneTools) on the product CD shipped with your modem. In general, the modem will work with most data communications software packages.
1. Insert the MultiModemII CD into your CD-ROM drive. Allow Autorun to bring up the introductory screen. 2. Click on the PhoneTools icon and choose the appropriate language. 3. Follow the PhoneTools installation wizard. No input is needed. You may choose to view the “Readme” file and whether or not to run PhoneTools immediately. Windows NT/2000/XP Note: During installation, an advisory screen may appear saying “FAX capture driver installation” - this may cause a delay in the installation. This is normal. The installation process has not failed or stalled. Simply wait a few moments until this screen disappears. 4. After installation, you can launch PhoneTools either from a desktop icon or from the Start |
Programs menu. Typically, it’s not necessary to reboot before using PhoneTools.
Multi-Tech Systems, Inc. MT5600BA/BL Series User Guide (S000276E)
Example

Chapter 3 - Using the Front Panel
Chapter 3 - Using t 3 - Using t 3 - Using t 3 - Using t 3 - Using the Fr he Fr he Fr he Fr he Front Panel
Like any modem, your Multi-Tech modem operates only under the control of a communication program, such as the PhoneTools program included with the modem. It also operates under other general-purpose data communication programs, such as Windows Terminal and HyperTerminal. For information on how to use the modem with the communication program of your choice, please refer to the program’s documentation.
Modem C em C em C em C em Configuration
Your modem normally is configured through Windows or through the communication program you are using. The default settings work best for most purposes. See “Step 4: Install PhoneTools” in Chapter 2 for help in setting up your communication program.
You also can configure your modem either through the front panel or by sending AT commands to the modem. The AT commands can be found in the AT Reference Guide on the CD shipped with this modem.
Figure 3-1. Front panel
The MT5600BA-V.92 has six LED indicators on the front panel that indicate status and activity:
Receive Data. The RD indicator flashes when the modem is receiving data.
Transmit Data. The TD indicator flashes when the modem is transmitting data.
Carrier Detect. The CD indicator lights when the modem detects a valid carrier signal from another modem. It is on when the modem is communicating with the other modem, and off when the link is broken.
Off-Hook. The OH indicator lights when the modem is off-hook, which occurs when the modem is dialing, online, or answering a call. The LED flashes when the modem pulse-dials.
Terminal Ready. The TR indicator lights when a communication program is using the modem. It means the modem is ready for an outgoing or incoming call. It goes off when the communication program disconnects the serial port. When it goes off, a connected modem will disconnect.
Test Mode. The TM indicator lights when the modem is in test mode.
12 Multi-Tech Systems, Inc. MT5600BA/BL Series User Guide (S000276E)

Chapter 3 - Using the Front Panel
Liquid Cr Liquid Cr Liquid Cr Liquid Cr Liquid Crystal Disp al Disp al Disp al Disp al Display (LCD)
The MultiModemII’s backlit liquid crystal display (LCD) has two functions: to display the current status of the modem and to display configuration menus, which are selected using the four pushbuttons on the front panel.
Option Sele n Sele n Sele n Sele n Selection
To select most configuration options, simply display the option in the LCD, and then press the Enter button to select it. An OPTION SET message appears to confirm the selection. To exit the OPTION SET message, press any button.
Some options, such as password options and phone number options, require you to enter a character string. To select a character, press the ÇÅ and È buttons. To go to the next character position, press the Æ button. To backspace, press the Æ button before selecting a character. To exit without saving, press the Æ button several times. To save a character string, press the Enter button.
Menu St Menu St Menu St Menu St Menu Structure
The LCD menus have a tree structure with multiple trunks, limbs, branches, and twigs. For a schematic view, refer to the menu map on the next page.
Trunks are the major divisions of the menu tree. There are seven trunks: Status, Basic Options, Ad- vanced Options, Remote Configuration, Diagnostics, Phone Number Memory, and Caller ID. Use the ÇÅ and È buttons to move between trunks.
Limbs are subdivisions of trunks. Use the Æ button to move from a trunk onto its first limb, and the ÇÅ and È buttons to move between limbs on the trunk.
Branches are subdivisions of limbs. Use the Æ button to move from a limb onto its first branch, and the ÇÅ and È buttons to move between branches on the limb.
Twigs are status screens and options that are accessible only from branches. Use the Æ button to move from a branch to its first status screen or option; then press the ÇÅ and È buttons to move between options, and press the Enter button to select an option.
13 Multi-Tech Systems, Inc. MT5600BA/BL Series User Guide (S000276E)

Chapter 3 - Using the Front Panel

Menu O Menu O Menu O Menu O Menu Overview
Region Profile B5 Region Profile XX? Current Setting = 02
14 Multi-Tech Systems, Inc. MT5600BA/BL Series User Guide (S000276E)

Chapter 3 - Using the Front Panel
Status Trunk
The Status Trunk shows the current operating status of the modem. Limb changes are automatic, but certain options can be accessed by pressing the Æ button. Note that when the modem is online, pressing the Æ button shows the connect status, including the data speed, connection type, and compression type.
15 Multi-Tech Systems, Inc. MT5600BA/BL Series User Guide (S000276E)
If Idle · If Online

Chapter 3 - Using the Front Panel

Basic Opt c Opt c Opt c Opt c Options Trunk
Use the Basic Options Trunk to configure the modem’s basic operating conditions. When entering a number, use the ÇÅ and È buttons to scroll through a list of digits and characters. To go to the next position, press the Æ button. To back up or to exit without dialing, press the Æ button several times.
16 Multi-Tech Systems, Inc. MT5600BA/BL Series User Guide (S000276E)

Chapter 3 - Using the Front Panel
Basic Opt c Opt c Opt c Opt c Options Trunk, continued
Continued from previous page
17 Multi-Tech Systems, Inc. MT5600BA/BL Series User Guide (S000276E)

Chapter 3 - Using the Front Panel

Advanced Opt ed Opt ed Opt ed Opt ed Options Trunk
Use the Advanced Options Trunk to configure RS-232, dial backup, and callback security options. When entering a number or password, use the ÇÅ and È buttons to select a character or digit. To go to the next position, press the Æ button. To backspace or to exit, press the Æ button several times.
18 Multi-Tech Systems, Inc. MT5600BA/BL Series User Guide (S000276E)

Chapter 3 - Using the Front Panel
Advanced Opt ed Opt ed Opt ed Opt ed Options Trunk, continued
Continued from previous page
19 Multi-Tech Systems, Inc. MT5600BA/BL Series User Guide (S000276E)

Chapter 3 - Using the Front Panel
Remote C emote C emote C emote C emote Configuration Opt n Opt n Opt n Opt n Options Trunk
Use the Remote Configuration Options Trunk to enable or disable remote configuration on the modem, and to change the password. When entering the password, use the ÇÅ and È buttons to scroll through the alphabet. To go to the next character position, press the Æ button. To backspace or to exit, press the Æ button several times.
Diagnostic Opt c Opt c Opt c Opt c Options Trunk
Use the Diagnostic Options Trunk to run loopback tests on the modem. When a test is in progress, the TM indicator lights.
20 Multi-Tech Systems, Inc. MT5600BA/BL Series User Guide (S000276E)

Chapter 3 - Using the Front Panel
Phone Number ne Number ne Number ne Number ne Number Memory Options Trunk
The MultiModemII can store up to four telephone numbers for speed dialing. Use the Phone Number Memory Options Trunk to store, list, and dial these numbers. When entering a number, use the ÇÅ and È buttons to scroll through the available digits and dialing commands. To go to the next position, press the Æ button. To backspace or to exit, press the Æ button several times.
Caller ID Opt ID Opt ID Opt ID Opt ID Options Trunk
Use the Caller ID Options Trunk to enable or disable Caller ID operation.
21 Multi-Tech Systems, Inc. MT5600BA/BL Series User Guide (S000276E)

Chapter 3 - Using the Front Panel
Menu Opt Menu Opt Menu Opt Menu Opt Menu Options
This section describes important LCD screens and options. Many, but by no means all, of the options have AT command equivalents.
Status screens display the current status of the modem. Though limb changes are automatic, certain options can be selected by pressing the Æ button.
STATUS = IDLE. The modem is ready but inactive. This screen appears when the modem is first turned on, and is the starting point for accessing all other screens. Three options are available from this screen by pressing the Æ button:
MANUAL ORIG.? Places the modem in originate mode for the time specified by register S7. Use this option to connect to a remote modem by manually dialing the number on a phone connected to the local modem. When the remote modem answers, press the Enter button to establish a connection with the remote modem. You can also use this option to temporarily place the modem in originate mode for back-to-back testing.
MANUAL ANSWER? Places the modem in answer mode for the time specified by register S7. You can use this option to temporarily place the modem in answer mode for back-to-back testing.
BUSY OUT MODEM? Takes the modem out of service by putting it into an off-hook state so that a calling modem receives a busy signal.
MODEM BUSIED OUT. Shows that the modem is busied out. To return the modem to normal service, press Æ, Enter.
STATUS = ONLINE. The modem is connected to another modem. Two options are available from this screen by pressing the Æ button:
Connect Status. Shows the connect speed, connection type, and error correction being used.
DISCONNECT? Press the Enter button to force the modem to hang up. Same as the ATH command.
RINGING. A remote modem or caller is attempting to establish a connection. One option is available from this screen by pressing the Æ button:
MANUAL ANSWER? Forces the modem to answer the phone. You can use this option to establish a connection if autoanswer is turned off (S0=0). Same as the ATA command.
22 Multi-Tech Systems, Inc. MT5600BA/BL Series User Guide (S000276E)

Chapter 3 - Using the Front Panel
Basic Opt c Opt c Opt c Opt c Options
The following screens are used to configure the modem’s basic operating conditions.
ONLINE OPTIONS. The following screens are used to configure the online operation of the modem:
LINE TYPE OPTIONS. Use the Æ and Enter buttons to select from the following line types: dial-up (PSTN), two-wire leased line originate or answer, and four-wire leased line originate or answer.
ERROR CORRECTION OPTIONS. Use the Æ and Enter but- tons to turn error correction on or off, or to select automatic error correction. Same as the &E0, &E1, and &E2 commands.
FLOW CONTROL OPTIONS. Use the Æ and Enter buttons to select no flow control, hardware flow control, or software flow control. Same as the &E3, &E4, and &E5 commands.
DIALING OPTIONS. The following screens are used to configure dialing options or to dial manually.
TONE/PULSE. Use the Æ and Enter buttons to select between DTMF tone dialing and pulse dialing. Same as the T and P com- mands.
BLIND/SMART DIAL OPTIONS. Use the Æ and Enter buttons to select blind dialing, in which the modem sends the OK, CON- NECT, RING, NO CARRIER, ERROR and NO ANSWER mes- sages to the computer and does not look for a dial tone or busy signal, or smart dialing, in which the modem sends all messages to the computer, including NO DIALTONE and BUSY. Same as the X0 and X4 commands.
DIAL NUMBER. Use the front panel buttons to enter a phone number and dial it. To scroll through a list of digits and charac- ters, press the ÇÅ and È buttons. To go to the next position, press the Æ button. To back up or to exit without dialing, press the Æ button several times. To dial the number, press the Enter button. Same as the D command.
DTR DIALING. Use the Æ and Enter buttons to enable or dis- able DTR dialing. DTR dialing is popular in synchronous applica- tions. In DTR dialing, the modem automatically dials the number stored in memory location 0 when it detects a high DTR (Data Terminal Ready) signal on the RS-232 interface. The DTR signal must remain high for the duration of the call. To store the DTR dialing number, use the &Z0= command or the ENTER PHONE #0 menu option.
23 Multi-Tech Systems, Inc. MT5600BA/BL Series User Guide (S000276E)

Chapter 3 - Using the Front Panel
COMMAND MODE OPTIONS. The following screens are used to configure result code responses.
ENABLE/DISABLE RESPONSE. Use the Æ and Enter buttons to enable or disable the sending of result codes to the computer. Same as the Q0 and Q1 commands.
VERBOSE/TERSE RESPONSE. Use the Æ and Enter buttons to select verbose or terse result codes. Same as the V0 and V1 commands.
ENABLE/DISABLE CMD MODE. Use the Æ and Enter buttons to enable or disable the modem’s ability to accept AT commands .
SYNC/ASYNC OPTIONS. Use the Æ and Enter buttons to select the method of data transmission.
ASYNC, NORM? Normal asynchronous transmission using the AT command set.
ASYNC, V.25bis? Asynchronous transmission using the V.25bis command set.
SYNC, NORM? Normal synchronous transmission using any command set.
V.25bis HDLC NRZ? V.25bis synchronous transmission using NRZ encoding.
V.25bis HDLC NRZI? V.25bis synchronous transmission using NRZI encoding.
V.25bis BISYNC? V.25bis bisynchronous transmission.
RESET FACTORY DEFAULTS. Use the Æ and Enter buttons to reset Profile 0 and the modem’s active configuration to the factory defaults. Same as the AT&F&W command string.
CONNECT RATE OPTIONS. Use the Æ and Enter buttons to change the modem’s serial port and data transmission speeds.
SERIAL BAUD RATE. Use the Æ and Enter buttons to select the modem’s serial port speed. The valid range is 1200 to 115200 bps. Same as the $SB commands.
MODEM SPEED. Use the Æ and Enter buttons to select the modulation protocol to use in originating or answering a connection. This also selects the maximum transmission speed at which the modem can operate. Same as the +MS=[mod] command.
24 Multi-Tech Systems, Inc. MT5600BA/BL Series User Guide (S000276E)

Chapter 3 - Using the Front Panel
Advanced Opt ed Opt ed Opt ed Opt ed Options
RS232 OPTIONS. The following screens are used to configure the RS-232 interface.
DTR OPTIONS. Use the Æ and Enter buttons to select how the modem responds to the high to low transition of the DTR signal sent by the computer. DTR NORMAL causes the modem to hang up; IGNORE DTR allows operation with computers that do not provide DTR; and RESET ON DTR È causes the modem to perform a soft reset as if the Z command were received. Same as the &D0, &D2, and &D3 commands.
CARRIER DETECT OPTIONS. Use the Æ and Enter buttons to select whether CD will be forced high (CD FORCED ON) or whether it will go high when the remote modem’s carrier signal is detected, and go low when the carrier signal is not detected (CD NORMAL). Same as the &C0 and &C1 commands. When using callback security on UNIX systems, select CD LOW IN CB to force CD low until the proper callback security password has been entered or until a disconnect occurs. This prevents the UNIX login prompt from being displayed before the callback se- curity ENTER PASSWORD prompt appears. Select CD NOR- MAL IN CB to disable this feature. Same as the &C5 and &C4 commands.
CTS OPTIONS. Use the Æ and Enter buttons to select whether the CTS state will follow the RTS state when on line (CTS NORM) or whether CTS will always be high (CTS ON). Same as the &R0 and &R1 commands.
DIALBACKUP/LL OPTIONS. The following screens are used to configure dial back- up for four-wire leased line operation. For more information, see Chapter 4, “Leased Line Operation.”
DIAL BACKUP NUMBER. Use to enter a dial backup number. To scroll through a list of digits and characters, press the ÇÅ and È buttons. To go to the next position, press the Æ button. To back up or to exit without saving, press the Æ button several times. To save the number, press the Enter button. Note: Only 16 characters can be displayed at a time. To see characters 17–30, press the È button. To go to the previous screen, press the Å button. To go to the next screen, press the Æ button.
TIME TO RESTORE (S15). Sets how frequently leased line restoral attempts occur when the modems are in dial backup mode. The restore time interval can be set from 10 to 255 min- utes in one minute increments. A value of 0 disables dial back- up. Same as the S15= command.
DIALBACKUP TIME (S17). Use to set how long the modem waits after a leased line failure before it attempts a dial backup connection. The timer can be set from 1 to 255 minutes in one minute increments. Same as the S17= command.
25 Multi-Tech Systems, Inc. MT5600BA/BL Series User Guide (S000276E)

Chapter 3 - Using the Front Panel
CALLBACK SECURITY. Use the Æ and Enter buttons to turn callback security on or off. Same as the #DB0 and #DB1 commands. For more information about call- back security, see Chapter 6, “Callback Security.”
PASSWORD SETUP. Use to enter callback security passwords in memory locations 1–30. Each password must be six to ten characters in length. To scroll through a list of digits and charac- ters, press the ÇÅ and È buttons. To go to the next position, press the Æ button. To back up or to exit without saving, press the Æ button several times. To save the password, press the Enter button. Same as the #CBP= command.
CALLBACK NUMBER. Use to enter callback security phone numbers in memory locations 1–30. Each number can be up to 30 characters long. Same as the #CBN= command. Note: Only 16 characters can be displayed at a time. To see characters 17–30, press the È button. To go to the previous screen, press the Å button. To go to the next screen, press the Æ button.
S-REGISTER OPTIONS. Use the Æ, È, and Enter buttons to display the current S-register values and enter new values. Same as the Sr? and Sr=n commands.
VIEW S-REGISTER SETTINGS. Use the Æ, È, ÇÅ, and Enter buttons to select the number of the S-register whose value you want displayed. To scroll through a list of digits, press the ÇÅ and È buttons. To go to the next position, press the Æ button. To back up or to exit without saving, press the Æ button several times. To display the value, press the Enter button. Same as the Sr? command.
SET S-REGISTER. Use the Æ, È, ÇÅ, and Enter buttons to select the number of the S-register whose value you want to change, and the value you want to enter. To scroll through a list of digits, press the ÇÅ and È buttons. To go to the next posi- tion, press the Æ button. To back up or to exit without saving, press the Æ button several times. Same as the Sr=n com- mand.
MONITOR OPTIONS. Use the Æ, È, and Enter buttons to display line quality and the line signal-to-noise ratio.
LINE QUALITY. Use the Æ and Enter buttons to display line signal quality as a three-digit number. The higher order byte of the EQM value is displayed. Based on the EQM value, retrain or fallback/fall forward may be initiated if enabled by %E1 or %E2. Same as the %Q command.
SIGNAL TO NOISE RATIO. Use the Æ and Enter buttons to display the line signal-to-noise ratio in dB.
26 Multi-Tech Systems, Inc. MT5600BA/BL Series User Guide (S000276E)

Chapter 3 - Using the Front Panel
Remote C emote C emote C emote C emote Configuration Opt n Opt n Opt n Opt n Options
The following screens are used to configure remote configuration options. For more information about remote configuration, see Chapter 5, “Remote Configuration.”
ENABLE/DISABLE R.C. Use the Æ and Enter buttons to turn remoteconfiguration on or off.
REMOTE CONFIG. PASSWORD. Use to enter the remote con- figuration password. To scroll through a list of digits and charac- ters, press the ÇÅ and È buttons. To go to the next position, press the Æ button. To back up or to exit without saving, press the Æ button several times. To save the password, press the Enter button.
Diagnostic Opt c Opt c Opt c Opt c Options
Use the following screens to turn loopback tests on and off.
ANALOG LOOPBACK. Press the Æ and Enter buttons to start the analog loopback test. The TEST IN PROGRESS screen appears. To stop the test, press the Æ and Enter buttons again.
DIGITAL LOOPBACK. Press the Æ and Enter buttons to start the local digital loopback test. The TEST IN PROGRESS screen appears. To stop the test, press the Æ and Enter but- tons again. Same as the &T3 command.
REMOTE DIGITAL LOOPBACK. Press the Æ and Enter but- tons to start the remote digital loopback test. The TEST IN PROGRESS screen appears. To stop the test, press the Æ and Enter buttons again. Same as the &T6 command.
Phone Number ne Number ne Number ne Number ne Number Memory Options
Use the following screens to list, enter, and dial stored phone numbers. Up to four phone numbers can be stored. The number in memory location 0 is used for DTR dialing, if DTR dialing is enabled. Note: Only 16 characters can be displayed at a time. To display characters 17–30, press the È button. To go to the previous screen, press the Å button. To go to the next screen, press the Æ button.
LIST PHONE NUMBERS. Press the Æ button several times to display the phone number stored in each memory location.
ENTER PHONE NUMBERS. Use to store up to four phone num- bers in memory locations 0–3. Each number can have up to 30 characters. To scroll through a list of digits and characters, press the ÇÅ and È buttons. To go to the next position, press the Æ button. To back up or to exit without saving, press the Æ button several times. To save the number, press the Enter button. Same as the &Z= commands.
DIAL STORED NUMBERS. Press the Æ and Enter buttons to dial a stored phone number. Same as the DS= commands.
27 Multi-Tech Systems, Inc. MT5600BA/BL Series User Guide (S000276E)

Chapter 3 - Using the Front Panel
Caller ID Opt ID Opt ID Opt ID Opt ID Options
Press the Æ and Enter buttons to enable formatted (FCID) or unformatted (UCID) Caller ID, or to disable Caller ID altogether. Same as the #CID=0, #CID=1, and #CID=2 commands.
28 Multi-Tech Systems, Inc. MT5600BA/BL Series User Guide (S000276E)

Chapter 4 - Leased Line Operation
Chapter 4 - L 4 - L 4 - L 4 - L 4 - Leased Line Oper ased Line Oper ased Line Oper ased Line Oper ased Line Operation
This chapter describes how to use the MultiModemII modem on a leased line.
A leased line is a private, permanent, telephone connection between two points. Unlike normal dialup connections, a leased line is always active. The modems automatically connect when they are attached to the line and are turned on. Because a leased line is always active, one of the two modems on the line must be configured as the originate modem and the other as the answer modem; however, it does not matter which is which.
In the event of an interruption, leased line modems automatically reconnect when the data line or power is restored. The modem also supports dial backup, which enables the modem to automatically switch to a dial-up connection if the leased line goes down.
The modem supports both two-wire and four-wire leased-line operation.
Two-Wire Set e Set e Set e Set e Setup
È, Æ, È, È, È, Æ. The CURRENT SETTING= screen appears.
29 Multi-Tech Systems, Inc. MT5600BA/BL Series User Guide (S000276E)

Chapter 4 - Leased Line Operation
Four-Wire Set e Set e Set e Set e Setup
30 Multi-Tech Systems, Inc. MT5600BA/BL Series User Guide (S000276E)

Chapter 4 - Leased Line Operation
Dial B Dial B Dial B Dial B Dial Backup and L kup and L kup and L kup and L kup and Leased-Line R ased-Line R ased-Line R ased-Line R ased-Line Restoral
For four-wire leased line operation, the MT5600BA-V.92 modem has a dial backup capability, in which the modem is connected to a standard dial-up line as well as to the leased line. If the leased line fails, the originate modem automatically dials and connects to the answer modem through the standard telephone network. While it is in dial backup mode, the modem periodically checks the leased line to see if it is operational. If the line is operational, the modem then attempts to restore the leased line. If the modem detects that it is not connected to the standard telephone network when the leased line fails, it immediately switches to leased line restoral.
The dial-back timer, register S17, determines how long the modem waits after a leased line failure before it attempts a dial backup connection. The S17 default setting is one minute. During that minute, the originate modem tries to establish the leased line link. If the leased line is established during that time, the S17 timer is cleared and everything is back to normal. If the timer expires, the modem attempts a dial backup connection. The purpose of the timer for the answer modem is to determine when it can accept a dial-up call. Dial-back starts only when both timers have expired and the leased line is still down.
The restore timer, register S15, determines how frequently restoral attempts occur when the modems are in dial backup mode. S15 can be set from 10 to 255 minutes in one minute increments. A value of 0 disables dial backup. The default value is 30 minutes.
The dial backup number must be set from the front panel of the modem.
Dial B Dial B Dial B Dial B Dial Backup and L kup and L kup and L kup and L kup and Leased Line R ased Line R ased Line R ased Line R ased Line Restoral Set al Set al Set al Set al Setup
31 Multi-Tech Systems, Inc. MT5600BA/BL Series User Guide (S000276E)

Chapter 4 - Leased Line Operation
16 .Dial backup and leased line restoral setup is complete.
32 Multi-Tech Systems, Inc. MT5600BA/BL Series User Guide (S000276E)

Chapter 5 - Remote Configuration
Chapter 5 - R 5 - R 5 - R 5 - R 5 - Remote C emote C emote C emote C emote Configuration
Remote configuration is a network management tool that allows you to configure modems anywhere in your network from one location. With password-protected remote configuration, you can issue AT commands to a remote MultiModemII modem for maintenance or troubleshooting as if you were on-site.
Basic P c P c P c P c Procedure
The following steps are valid regardless of whether the connection is established by the local or the remote MultiModemII modem.
Online Remote Access Remote password:
Multi-Tech modems are shipped with a default setup password (MULTITECH). Because anyone who has an owner’s manual knows the default setup password, for security you should change the password and possibly also the remote configuration escape character.
Changing t ing t ing t ing t ing the R he R he R he R he Remote C emote C emote C emote C emote Configuration Password
The remote configuration password can be changed only from the front panel of the modem:
33 Multi-Tech Systems, Inc. MT5600BA/BL Series User Guide (S000276E)

Chapter 5 - Remote Configuration
Changing t ing t ing t ing t ing the R he R he R he R he Remote Esc emote Esc emote Esc emote Esc emote Escape C ape C ape C ape C ape Character
To improve security, you can change a remote modem’s remote configuration escape character. The remote configuration escape character is stored in register S13. The factory default is 42, which is the ASCII code for the asterisk character (*). Setting S13 to 0 (zero) disables remote configuration entirely— but if you do this remotely, you won’t be able to change it back remotely!
34 Multi-Tech Systems, Inc. MT5600BA/BL Series User Guide (S000276E)

Chapter 6 - Callback Security
Chapter 6 - Cal 6 - Cal 6 - Cal 6 - Cal 6 - Callback Security
This chapter describes how to use callback security with your modem.
Callback security protects your network from unauthorized access and helps control long distance costs. When callback security is enabled, all callers are requested to enter a password. If the password is invalid, the caller can try twice more before the modem hangs up. If the password is valid, the modem hangs up and returns the call by dialing the phone number associated with the password.
It is possible to implement password protection without callback by storing a hyphen (-) before the callback phone number. The caller must then append a hyphen to his password to establish the direct connection.
The modem can store up to 30 callback phone numbers and 30 callback passwords. Phone numbers can be up to 30 characters long and can contain the pause (,) and wait (W) characters in addition to the digits and characters normally found on a touch-tone keypad. Passwords can be up to 10 characters long.
Callback phone numbers are associated with callback passwords by being assigned to the same callback memory location. For example, if you assign the password “APRICOT” to memory location 16 and, in a separate operation, also assign phone number 6127853000 to memory location 16, the modem calls phone number 6127853000 when it receives the password “APRICOT.”
Because there is no way to examine the passwords and phone numbers stored in the modem, it is important to write them down as you enter them. A form that you can print out for this purpose is provided on the last page of this chapter.
Setup P up P up P up P up Procedures
Turning Cal ning Cal ning Cal ning Cal ning Callback Security On and O On and O On and O On and O On and Off
AT Command Method AT Command Method AT Command Method AT Command Method AT Command Method
35 Multi-Tech Systems, Inc. MT5600BA/BL Series User Guide (S000276E)

Chapter 6 - Callback Security
Front Panel Met anel Met anel Met anel Met anel Method
Assigning Cal ning Cal ning Cal ning Cal ning Callback Passwords
AT Command Met and Met and Met and Met and Method
Front Panel Met anel Met anel Met anel Met anel Method
36 Multi-Tech Systems, Inc. MT5600BA/BL Series User Guide (S000276E)

Chapter 6 - Callback Security
Assigning Cal ning Cal ning Cal ning Cal ning Callback Phone Numbers ne Numbers ne Numbers ne Numbers ne Numbers
AT Command Method AT Command Method AT Command Method AT Command Method AT Command Method
2. To store a callback phone number in the first memory location, type AT#CBN01=xxxxxxxxxx, where xxxxxxxxxx is the dialing string, and press ENTER. The dialing string can include the digits 0 through 9 and any of the following characters: #, *, comma (,), semicolon (;), W, A, B, C, and D. Up to 30 characters can be used. Example: AT#CBN01=9,16127853000. If a direct connection with password protection, but without hangup and callback, is desired, the first character in the dialing string should be a hyphen (-).
Front Panel Method Front Panel Method Front Panel Method Front Panel Method Front Panel Method
37 Multi-Tech Systems, Inc. MT5600BA/BL Series User Guide (S000276E)

Chapter 6 - Callback Security
Calling P ling P ling P ling P ling Procedure
Use the following procedure to call a modem that has callback security enabled.
38 Multi-Tech Systems, Inc. MT5600BA/BL Series User Guide (S000276E)

Chapter 6 - Callback Security
Callback Security Commands
The following AT commands are used with callback security.
Command: #DBn Callback Enable/Disable Values: n = 0 or 1 Default: 0 Description: Enables or disables callback security. When callback security is enabled, phone number memory locations 0–4, used for quick dialing and DTR dialing, become unavailable and are replaced by callback security memory locations 1–30. The phone number memory locations and their contents are restored when callback security is disabled.
#DB0 Disables callback security. #DB1 Enables callback security.
Command: #CBNy=[-]x Store Callback Number Values: y = 01–30 x = dialing string Default: None Description: Stores the callback dialing string x in memory location y. The dialing string can include the digits 0 through 9 and any of the following characters: #, *, comma (,), semicolon (;), W, A, B, C, and D. Up to 30 characters can be used. Example: AT#CBN01=9,16127853000. If the optional - character precedes the dialing string, and the caller appends the same character to the password, the caller is connected immediately, and the hangup and callback are skipped.
Command: #CBPy=x Store Callback Password Values: y = 01–30 x = password (6–10 characters) Defaults: None Description: Stores callback security password x in memory location y. The password must have 6 to 10 characters.
39 Multi-Tech Systems, Inc. MT5600BA/BL Series User Guide (S000276E)

Chapter 6 - Callback Security
Callback Assignments F nments F nments F nments F nments Form
Password Phone Number Phone Number Phone Number Phone Number Phone Number
02 02 02 02 02
03 03 03 03 03
04 04 04 04 04
05 05 05 05 05
06 06 06 06 06
07 07 07 07 07
08 08 08 08 08
08 08 08 08 08
10 10 10 10 10
11 11 11 11 11
12 12 12 12 12
13 13 13 13 13
14 14 14 14 14
15 15 15 15 15
16 16 16 16 16
17 17 17 17 17
18 18 18 18 18
19 19 19 19 19
20 20 20 20 20
21 21 21 21 21
22 22 22 22 22
23 23 23 23 23
24 24 24 24 24
25 25 25 25 25
26 26 26 26 26
27 27 27 27 27
28 28 28 28 28
29 29 29 29 29
30 30 30 30 30
40 Multi-Tech Systems, Inc. MT5600BA/BL Series User Guide (S000276E)

Chapter 7 - Troubleshooting
Chapter 7 - 7 - 7 - 7 - 7 - Troubleshooting
Your modem was thoroughly tested at the factory before it was shipped. If you are unable to make a successful connection, or if you experience data loss or garbled characters during your connection, it is possible that the modem is defective. However, it is more likely that the source of your problem lies elsewhere. The following symptoms are typical of problems you might encounter:
If you experience problems, please check the following possibilities before calling Technical Support (see Appendix C).
None of ne of ne of ne of ne of the Indi he Indi he Indi he Indi he Indicators Ligh rs Ligh rs Ligh rs Ligh rs Light
When you turn on the modem, the LED indicators on the front panel should flash briefly as the modem runs a self-test, and the liquid crystal display (LCD) should light. If the LEDs and LCD remain off, the modem is probably not receiving power.
41 Multi-Tech Systems, Inc. MT5600BA/BL Series User Guide (S000276E)

Chapter 7 - Troubleshooting
The Mod he Mod he Mod he Mod he Modem D em D em D em D em Does Not oes Not oes Not oes Not oes Not Respond to C nd to C nd to C nd to C nd to Commands
Windows 3.1x: To look for address or IRQ conflicts, in Program Manager select File | Run, type MSD, and press ENTER. Then select Mouse, COM Ports, and IRQ Status, and note the addresses and IRQs that are in use. If you find an IRQ conflict, note which IRQs are not being used, then change one of the conflicting devices to use one of the unused IRQs. If you find an address conflict, change the address of one of the conflicting devices.
To change a port address or IRQ in Windows 3.1x, double-click the Control Panel icon, then the Ports icon. Click on the port you want to change, click Settings, click Advanced, and select the new port address and/or interrupt. If you wish to use COM3 or COM4, note that COM3 shares an IRQ with COM1, as does COM4 with COM2, so you should change their IRQs to unused ones, if possible.
42 Multi-Tech Systems, Inc. MT5600BA/BL Series User Guide (S000276E)

Chapter 7 - Troubleshooting
Windows 9x: Right-click on My Computer, select Properties from the menu, click on the Device Manager tab, double-click on Ports, then double-click on the communication port your modem is connected to. In the port’s Properties sheet, click on the Resources tab to see the port’s input/ output range and interrupt request. If another device is using the same address range or IRQ, it appears in the Conflicting Device List. Uncheck Use automatic settings to change the port’s settings so they do not conflict with the other device, or select the port the conflicting device is on and change it instead. If you need to open your computer to change switches or jumpers on the conflicting device; refer to the device’s documentation.
Windows NT 4.0: To look for address or IRQ conflicts, click Start, Programs, Administrative Tools (Common), and Windows NT Diagnostics. In the Windows NT Diagnostics dialog box, click the Resources tab to see which input/output ranges and interrupt requests are in use. If you need to open your computer to change switches or jumpers on the conflicting device; refer to the device’s documentation.
The Mod he Mod he Mod he Mod he Modem Cannot em Cannot em Cannot em Cannot em Cannot Connect When Dialing hen Dialing hen Dialing hen Dialing hen Dialing
There can be several reasons the modem fails to make a connection. Possibilities include:
You can narrow the list of possibilities by using extended result codes. Extended result codes are enabled by default. If they have been disabled, include V1X4 in the modem’s initialization string, or in terminal mode enter ATV1X4 and press ENTER. When you dial again, the modem reports the call’s progress.
43 Multi-Tech Systems, Inc. MT5600BA/BL Series User Guide (S000276E)

Chapter 7 - Troubleshooting
If you must dial 9 to get an outside line, the easiest way to dial it automatically is to include it in the modem’s dial prefix, e.g., ATDT9,. Note the comma, which inserts a pause before the number is dialed. By inserting 9, into the dial prefix, you do not have to include it in each directory entry.
To change the dial prefix in Windows 95 HyperTerminal, select Connect from the Call menu, click Dialing Properties, and type 9 in the local and long distance boxes in How I dial from this location.
The Mod he Mod he Mod he Mod he Modem Disc em Disc em Disc em Disc em Disconnects While Online hile Online hile Online hile Online hile Online
You can automatically disable Call Waiting by including the disabling code in the modem’s dial prefix (e.g., ATDT*70,—note the comma, which inserts a pause before the number is dialed). To change the dial prefix in Windows Terminal, select Settings | Modem Commands. To change it in HyperTerminal, select Connect from the Call menu, click Dialing Properties, check This location has Call Waiting, and select the correct code for your phone service.
44 Multi-Tech Systems, Inc. MT5600BA/BL Series User Guide (S000276E)

Chapter 7 - Troubleshooting
The Mod he Mod he Mod he Mod he Modem Cannot em Cannot em Cannot em Cannot em Cannot Connect When Answering
File Transfer Is Slo Is Slo Is Slo Is Slo Is Slower Than I han I han I han I han It Should Be Should Be Should Be Should Be Should Be
Data Is Being Lo a Is Being Lo a Is Being Lo a Is Being Lo a Is Being Lost
45 Multi-Tech Systems, Inc. MT5600BA/BL Series User Guide (S000276E)

Chapter 7 - Troubleshooting
There Are G e G e G e G e Garbage C e C e C e C e Characters o cters o cters o cters o cters on t n t n t n t n the Mo he Mo he Mo he Mo he Monitor
The Mod he Mod he Mod he Mod he Modem D em D em D em D em Doesn’t Work with Cal h Cal h Cal h Cal h Caller ID
Fax and D and D and D and D and Data Sof a Sof a Sof a Sof a Software Can e Can e Can e Can e Can’t Run a Run a Run a Run a Run athe S he S he S he S he Same Time
46 Multi-Tech Systems, Inc. MT5600BA/BL Series User Guide (S000276E)

Appendix A - Regulatory Compliance
Appendix A - R - R - R - R - Regulatory Compliance
FCC P C P C P C P C Part 68 Telecom
4. The ringer equivalence number (REN) is used to determine the number of devices that may be connected to the telephone line. Excessive RENs on the telephone line may result in the device not ringing in response to an incoming call. In most, but not all, areas the sum of the RENs should not exceed 5.0. To be certain of the number of devices that may be connected to the line, as determined by the total RENs, contact the local telephone company.
Manufacturer: Multi-Tech Systems, Inc. Trade Name MultiModemII Model Number: MT5600BA FCC Registration No: AU7USA-33378-M5-E Ringer Equivalence No: 0.1A Modular Jack (USOC): RJ11C or RJ11W (single line) Service Center in USA: Multi-Tech Systems, Inc. 2205 Woodale Drive Mounds View, MN 55112 U.S.A. (763) 785-3500 (763) 785-9874 Fax
47 Multi-Tech Systems, Inc. MT5600BA/BL Series User Guide (S000276E)

Appendix A - Regulatory Compliance
Fax Branding St anding St anding St anding St anding Statement
The Telephone Consumer Protection Act of 1991 makes it unlawful for any person to use a computer or other electronic device, including fax machines, to send any message unless such message clearly contains the following information:
This information is to appear in a margin at the top or bottom of each transmitted page or on the first page of the transmission. (Adding this information in the margin is referred to as fax branding.)
Since any number of fax software packages can be used with this product, the user must refer to the fax software manual for setup details. Typically the fax branding information must be entered via the configuration menu of the software.
Canadian Limit dian Limit dian Limit dian Limit dian Limitations Not ns Not ns Not ns Not ns Notice
Notice: The ringer equivalence number (REN) assigned to each terminal device provides an indication of the maximum number of terminals allowed to be connected to a telephone interface. The termination on an interface may consist of any combination of devices subject only to the requirement that the sum of the ringer equivalence numbers of all the devices does not exceed 5.
Before installing this equipment, users should ensure that it is permissible to be connected to the facilities of the local telecommunications company. The equipment must also be installed using an acceptable method of connection. The customer should be aware that compliance with the above conditions may not prevent degradation of service in some situations. Repairs to certified equipment should be made by an authorized Canadian maintenance facility designated by the supplier. Any repairs or alterations made by the user to this equipment or equipment malfunctions may give the telecommunications company cause to request the user to disconnect the equipment.
Users should ensure for their own protection that the electrical ground connections of the power utility, telephone lines and internal metallic water pipe system, if present, are connected together. This precaution may be particularly important in rural areas.
48 Multi-Tech Systems, Inc. MT5600BA/BL Series User Guide (S000276E)

Appendix A - Regulatory Compliance
EMC, Safety, and R&T and R&T and R&T and R&T and R&TTE Directive C e C e C e C e Compliance
International Mod nal Mod nal Mod nal Mod nal Modem R em R em R em R em Restrictions
Some dialing and answering defaults and restrictions may vary for international modems. Changing settings may cause a modem to become non-compliant with national telecom requirements in specific countries. Also note that some software packages may have features or lack restrictions that may cause the modem to become non-compliant.
New Zealand Telecom Warning Not ning Not ning Not ning Not ning Notice
1. The grant of a Telepermit for any item of terminal equipment indicates only that Telecom has accepted that the item complies with minimum conditions for connection to its network. It indicates no endorsement of the product by Telecom, nor does it provide any sort of warranty. Above all, it provides no assurance that any item will work correctly in all respects with another item of Telepermitted equipment of a different make or model, nor does it imply that any product is compatible with all of Telecom’s network services.
This equipment is not capable under all operating conditions of correct operation at the higher speed which it is designated. 33.6 kbps and 56 kbps connections are likely to be restricted to lower bit rates when connected to some PSTN implementations. Telecom will accept no responsibility should difficulties arise in such circumstances.
49 Multi-Tech Systems, Inc. MT5600BA/BL Series User Guide (S000276E)

Appendix A - Regulatory Compliance
Use of pulse dialing, when this equipment is connected to the same line as other equipment, may give rise to ‘bell tinkle’ or noise and may also cause a false answer condition. Should such problems occur, the user should not contact the Telecom Faults Service.
The preferred method of dialing is to use DTMF tones, as this is faster than pulse (decadic) dialing and is readily available on almost all New Zealand telephone exchanges.
For repeat calls to the same number:
For automatic calls to different numbers:
For automatically answered incoming calls:
South African Not an Not an Not an Not an Notice
This modem must be used in conjunction with an approved surge protection device.
50 Multi-Tech Systems, Inc. MT5600BA/BL Series User Guide (S000276E)

Appendix B - Technical Specifications
Appendix B - B - B - B - B - Technical Specifications
Your MultiModemII modem meets the following specifications:
Model Number MT5600BA-V.92, MT5600-V.90, MT5600BL
Server-to-Client 56K or V.92 speeds when accessing a 56K or V.92 Data Rates server (actual speed depends on server capabilities and line conditions)
Client-to-Client 33600, 31200, 28800, 26400, 24000, 21600, 19200, 16800, Data Rates 14400, 12000, 9600, 7200, 4800, 2400, 1200, 0-300 bps
Fax Data Rates 14400, 12000, 9600, 7200, 4800, 2400, 300 bps
Data Format Serial, binary, synchronous and asynchronous
Commands AT, V.25bis, TIA/EIA TR.29 Class 2
Command Buffer 60 characters
Modem Compatibility ITU-T V.90, v.92; 56K ITU-T V.34 enhanced, V.34, V.32terbo, V.32bis, V.32, V.25bis, V.22bis, V.22; Bell 212A and 103/113; ITU-T V.42, V.42bis; ITU-T V.21 & V.23 in international versions, v.44
Fax Compatibility ITU-T Group 3, Class 1 and 2, T.4, T.30, V.21, V.27ter, V.29, V.17, and TIA/EIA TR29.2, V.34, V.17
Error Correction ITU-T V.42 (LAP-M or MNP 3 and 4)
Data Compression ITU-T V.42bis (4:1 throughput), MNP 5 (2:1 throughput)
Speed Conversion Serial port data rates adjustable to 300, 1200, 2400, 4800, 9600, 19200, 38400, 57600, 115200, and 230400 bps
Mode of Operation Fax online modes; full duplex over dial-up and two-wire or four-wire leased lines; data mode, command mode, online command mode, V.54 test mode
Flow Control XON/XOFF (software), RTS/CTS (hardware)
Transmission Level -11 dBm (dial-up—varies depending on country or region for which the modem is set), -10 dBm (leased-line)
Frequency Stability ±0.01%
Receiver Sensitivity -43 dBm under worst-case conditions
AGC Dynamic Range 43 dB
Interface TIA/EIA RS-232C/ITU-T V.24/V.28
Connectors DB25F RS-232C connector; two RJ-11 phone jacks (BA model) or three RJ-11 phone jacks (BL model); power connector
Cables Three modular telephone cords (USA); country- or region-specific cordage for International models; one 9-pin to 25-pin serial cable for International models; external power transformer Note: Any cables connected to the computer should be shielded to reduce interference.
51 Multi-Tech Systems, Inc. MT5600BA/BL Series User Guide (S000276E)
Trade Name MultiModemII™

Appendix B - Technical Specifications
Diagnostics Power-on self test, local analog loop, local digital loop, remote digital loop
Indicators 32-character backlit LCD for status and configuration information; LEDs for Transmit Data, Receive Data, Carrier Detect, Off Hook, Terminal Ready, and Test Mode
Speaker 1-inch speaker for call progress monitoring
Manual Controls Power switch, speaker volume control, four LCD control buttons
Environmental Temperature range 0°–50°C (32°–120°F) ambient under closed conditions; humidity range 20–90% (non-condensing)
Storage Temperature -10° to +85°C (14°–185°F)
Power Requirement 120 VAC, 60 Hz, 16 W; 230V/50 Hz optional (international)
Power Consumption 12 W @ 0.1 A typical
Dimensions 15.8 cm wide × 22.9 cm long × 3.6 cm high (6.2" × 9.0" × 1.4")
Weight 0.9 kg (2 lb.)
Limited Warranty 10 years
Intelligent Features Plug and Play; AT command compatible; autodial, redial, repeat dial; pulse or tone dial; dial pauses; auto answer; Caller ID; remote configuration; adaptive line probing; automatic symbol and carrier frequency during start-up, retrain, and rate renegotiation; DTMF detection; call status display, auto-parity and data rate selection; keyboard- and front panel-controlled modem options; monitor and LCD displays for modem options; non-volatile memory; storage of up to four command strings or telephone numbers of up to 40 characters each
52 Multi-Tech Systems, Inc. MT5600BA/BL Series User Guide (S000276E)

Appendix C - Warranty, Service, and Technical Support
Appendix C - C - C - C - C - Warranty, Service, and Technical Suppo al Suppo al Suppo al Suppo al Support
Multi-i-i-i-i-Tech Sy h Sy h Sy h Sy h Systems, Inc. Warranty & R & R & R & R & Repairs Polililililicies
Warranty Multi-Tech Systems, Inc., (hereafter “MTS”) warrants that its products will be free from defects in material or workmanship for a period of two, five, or ten years (depending on model) from date of purchase, or if proof of purchase is not provided, two, five, or ten years (depending on model) from date of shipment.
MTS MAKES NO OTHER WARRANTY, EXPRESS OR IMPLIED, AND ALL IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE ARE HEREBY DISCLAIMED.
This warranty does not apply to any products which have been damaged by lightning storms, water, or power surges or which have been neglected, altered, abused, used for a purpose other than the one for which they were manufactured, repaired by Customer or any party without MTS’s written authorization, or used in any manner inconsistent with MTS’s instructions.
MTS’s entire obligation under this warranty shall be limited (at MTS’s option) to repair or replacement of any products which prove to be defective within the warranty period or, at MTS’s option, issuance of a refund of the purchase price. Defective products must be returned by Customer to MTS’s factory – transportation prepaid.
MTS WILL NOT BE LIABLE FOR CONSEQUENTIAL DAMAGES, AND UNDER NO CIRCUMSTANCES WILL ITS LIABILITY EXCEED THE PRICE FOR DEFECTIVE PRODUCTS.
Repair Procedures for U.S. and Canadian Customers Repair Procedures for U.S. and Canadian Customers Repair Procedures for U.S. and Canadian Customers Repair Procedures for U.S. and Canadian Customers Repair Procedures for U.S. and Canadian Customers In the event that service is required, products may be shipped, freight prepaid, to our Mounds View, Minnesota factory:
Multi-Tech Systems, Inc. 2205 Woodale Drive Mounds View, MN 55112 Attn: Repairs, Serial #
A Returned Materials Authorization (RMA) is not required. Return shipping charges (surface) will be paid by MTS.
Please include, inside the shipping box, a description of the problem, a return shipping address (must have a street address, not P.O. Box), your telephone number, and, if the product is out of warranty, a check or purchase order for repair charges.
For out of warranty repair charges, go to http://www.multitech.com/documents/warranties
Extended two-year overnight replacement service agreements are available for selected products. Please call MTS at (888) 288-5470, extension 5308 or visit our Web site at http://www.multitech.com/programs/orc/ for details on rates and coverages.
Please direct your questions regarding technical matters, product configuration, verification that the product is defective, etc. to our Technical Support department at (800) 972-2439, or email tsupport@multitech.com. Please direct your questions regarding repair expediting, receiving, shipping, billing, etc. to our Repair Accounting department at (800) 328-9717 or (763) 717-5631, or email mtsrepair@multitech.com.
Repairs for damages caused by lightning storms, power surges, incorrect installation, physical abuse, or user caused damages are billed on a time-plus-materials basis.
53 Multi-Tech Systems, Inc. MT5600BA/BL Series User Guide (S000276E)

Appendix C - Warranty, Service, and Technical Support
Repair Procedures for International Customers (Outside U.S.A. and Repair Procedures for International Customers (Outside U.S.A. and Repair Procedures for International Customers (Outside U.S.A. and Repair Procedures for International Customers (Outside U.S.A. and Repair Procedures for International Customers (Outside U.S.A. and Canada) Your original point of purchase Reseller may offer the quickest and most economical repair option for your Multi-Tech product. You may also contact any Multi-Tech sales office for information about the nearest distributor or other repair service for your Multi-Tech product.
http://www.multitech.com/COMPANY/offices/DEFAULT.ASP
In the event that factory service is required, products may be shipped, freight prepaid to our Mounds View, Minnesota factory. Recommended international shipment methods are via Federal Express, UPS or DHL courier services, or by airmail parcel post; shipments made by any other method will be refused. A Returned Materials Authorization (RMA) is required for products shipped from outside the U.S.A. and Canada. Please contact us for return authorization and shipping instructions on any International shipments to the U.S.A. Please include, inside the shipping box, a description of the problem, a return shipping address (must have street address, not P.O. Box), your telephone number, and if the product is out of warranty, a check drawn on a U.S. bank or your company’s purchase order for repair charges. Repaired units shall be shipped freight collect, unless other arrangements are made in advance.
Please direct your questions regarding technical matters, product configuration, verification that the product is defective, etc., to our Technical Support department nearest you or email tsupport@multitech.com. When calling the U.S., please direct your questions regarding repair expediting, receiving, shipping, billing, etc., to our Repair Accounting department at
+(763) 717-5631 in the U.S.A., or email mtsrepair@multitech.com.
Repairs for damages caused by lightning storms, water, power surges, incorrect installation, physical abuse, or user-caused damages are billed on a time-plus-materials basis.
Repair Procedures for International Distributors Repair Procedures for International Distributors Repair Procedures for International Distributors Repair Procedures for International Distributors Repair Procedures for International Distributors Procedures for International Distributors of Multi-Tech products are on the distributor Web site.
http://www.multitech.com/PARTNERS/login/
Copyright ã Multi-Tech Systems, Inc. 2001 10-Sep-01
Online Warranty Registration
If you have access to the World Wide Web, you can register your Multi-Tech product online at http:// www.multitech.com/register/
U.S. and Canadian Customers U.S. and Canadian Customers U.S. and Canadian Customers U.S. and Canadian Customers U.S. and Canadian Customers In the event that service is required, products may be shipped, freight prepaid, to our Mounds View, Minnesota, factory:
Multi-Tech Systems, Inc. 2205 Woodale Drive Mounds View, MN 55112 Attn: Repairs, Serial #
54 Multi-Tech Systems, Inc. MT5600BA/BL Series User Guide (S000276E)

Appendix C - Warranty, Service, and Technical Support
A Returned Materials Authorization (RMA) is not required. Return shipping charges (surface) will be paid by MTS. Please include inside the shipping box a description of the problem, a return shipping address (must have street address, not P.O. Box), a telephone number, and if the product is out of warranty, a check or purchase order for repair charges.
For out of warranty repair charges, go to http://www.multitech.com/documents/warranties
Extended two-year overnight replacement agreements are available for selected products. Please call MTS at 888 288-5470, extension 5308, or visit our web site at http://www.multitech.com/PROGRAMS/orc/ for details on rates and coverages.
Please direct your questions regarding technical matters, product configuration, verification that the product is defective, etc., to our Technical Support department at 800 972-2439 or e-mail tsupport@multitech.com.
Please direct your questions regarding repair expediting, receiving, shipping, billing, etc., to our Repair Accounting department at 800 328-9717 or +763 785-3500, or e-mail mtsrepair@multitech.com.
Repairs for damages caused by lightning storms, water, power surges, incorrect installation, physical abuse, or user-caused damages are billed on a time-plus-materials basis.
International Customers (outside U.S.A. and Canada) International Customers (outside U.S.A. and Canada) International Customers (outside U.S.A. and Canada) International Customers (outside U.S.A. and Canada) International Customers (outside U.S.A. and Canada)
Your original point of purchase reseller may offer the quickest and most economical repair option for your Multi-Tech product. You may also contact any Multi-Tech sales office for information about the nearest distributor or other repair service for your Multi-Tech product: http://www.multitech.com/COMPANY/offices/ DEFAULT.ASP.
In the event that factory service is required, products may be shipped, freight prepaid, to our Mounds View, Minnesota, factory. Recommended international shipment methods are via Federal Express, UPS or DHL courier services, or by airmail parcel post; shipments made by any other method will be refused. A Returned Materials Authorization (RMA) is required for products shipped from outside the U.S.A. and Canada. Please contact us for return authorization and shipping instructions on any international shipments to the U.S.A. Please include, inside the shipping box, a description of the problem, a return shipping address (must have street address, not P.O. Box), your telephone number, and if the product is out of warranty, a check drawn on a U.S. bank or your company’s purchase order for repair charges. Repaired units will be shipped freight collect, unless other arrangements are made in advance.
Procedures for international distributors of Multi-Tech products are on the Distributor Web site at http:// www.multitech.com/PARTNERS/login/
Replacement Parts
SupplyNet, Inc, can supply you with replacement power supplies, cables and connectors for selected Multi- Tech products. You can place an order with SupplyNet via mail, phone, fax, or the Internet at the following addresses:
Mail: SupplyNet, Inc. 614 Corporate Way Valley Cottage, NY 10989 Phone: 800-826-0279 Fax: 914-267-2420 Email: info@supplynet.com Internet: http://www.thesupplynet.com
55 Multi-Tech Systems, Inc. MT5600BA/BL Series User Guide (S000276E)

Appendix C - Warranty, Service, and Technical Support
Technical Suppo al Suppo al Suppo al Suppo al Support
Multi-Tech Systems has an excellent staff of technical support personnel available to help you get the most out of your Multi-Tech product. If you have any questions about the operation of this unit, please call 800 972- 2439 (USA and Canada) or 763 785-3500 (international and local). Please have modem information avail- able. You can also contact Technical Support by e-mail at the following addresses: Country Email Telephone France: [email protected] +(33) 1-64 61 09 81 India: support@multitechindia.com +91 (124) 6340778 U.K.: support@multitech.co.uk +(44) 118 959 7774 U.S.A., Canada support@multitech.com 800 972-2439 Rest of world: support@multitech.com +763 717-5863
Please note the status of the modem before contacting Technical Support. Status information can include the state of the LED indicators, screen messages, diagnostic test results, problems with a specific application, etc.
Internet Sites
Multi-Tech is a commercial provider on the Internet. Multi-Tech has a Web site at http://www.multitech.com
56 Multi-Tech Systems, Inc. MT5600BA/BL Series User Guide (S000276E)

Appendix D - Upgrading the Firmware
Appendix D - Upg D - Upg D - Upg D - Upg D - Upgrading t ding t ding t ding t ding the Firmware
Your modem is controlled by semi-permanent software, called firmware, which is stored in flash memory. Firmware is nonvolatile; that is, it remains stored in memory when the modem is turned off. However, it can be changed by either the manufacturer or the user as bugs are fixed or new features are added.
Since the firmware in your modem is stored in flash memory, you can upgrade it yourself in a few minutes by using the following procedures.
Upgrade O e O e O e O e Overview
The upgrade procedure consists of the following steps, which are described in greater detail in the following sections.
You must know the model number and firmware version of your Multi-Tech modem to know whether or not you should update it.
ACF3_V1.702a_V90_P21_FSH
57 Multi-Tech Systems, Inc. MT5600BA/BL Series User Guide (S000276E)

Appendix D - Upgrading the Firmware
Identify the current version of the firmware at the Multi-Tech Web site. If your modem already has the current firmware, there is no need to update it.
58 Multi-Tech Systems, Inc. MT5600BA/BL Series User Guide (S000276E)

Appendix D - Upgrading the Firmware
Before you flash your modem, you should record the parameters that are currently stored in it, so you can reprogram it after flashing. After you have recorded them, send the AT&F command to the the modem to clear the stored parameters.
Before you begin the following procedure, read the README.TXT file extracted from the upgrade archive file. Note the file name for the boot code (e.g., F35ALOAD.S37) and the file name for the new firmware (e.g., BKQG300G.HEX).
Your modem has been updated. You can now open your terminal program to reprogram your modem parameters or to confirm the update by typing ATI3 in the terminal window and pressing Enter.
59 Multi-Tech Systems, Inc. MT5600BA/BL Series User Guide (S000276E)

Appendix E - Installing a Modem Under Linux
Appendix E - Inst E - Inst E - Inst E - Inst E - Installing a Mod ling a Mod ling a Mod ling a Mod ling a Modem Under Linux Under Linux Under Linux Under Linux Under Linux
This appendix explains how to install a modem on a computer operating under the Red Hat Linux 6.2 operating system. Other versions of Red Hat and other Linux operating systems should be similar. Briefly, in Linux, you do not need drivers for most standard external modems and most internal ISA bus modems. Programs in Linux commonly call upon the port, rather than the modem.
Standard Linux d Linux d Linux d Linux d Linux Serial P ial P ial P ial P ial Port Definitions
PC port Linux port Com1 ttyS0 Com2 ttyS1 Com3 ttyS2 Com4 ttyS3
Installation
Connect the external modem to an available serial port.
This section describes how to make sure Linux can talk to the modem and be able to dial up to the Internet. Linux can use different programs and desktops depending on who made the Linux operating system and what version it is. The following procedures use the most commonly installed components of Red Hat 6.2. More information can be found in your Linux OS owner’s manual.
Multi-Tech Systems, Inc. MT5600BA/BL Series User Guide (S000276E)

Appendix E - Installing a Modem Under Linux
Linux allows different graphic user interfaces (GUI). In the following steps, we’ll use the Gnome Desktop GUI and assume that the Internet Service Provider (ISP) you are calling assigns you the Domain Name Service (DNS) and Internet Protocol (IP) addresses. For more information on DNS or IP, see the Linux OS owner’s manual or contact your ISP.
To use the system for answering calls, Linux requires other programs to be installed, such as Mgetty, Mgetty+Sendfax, and others, depending on your requirements. Each vendor of Linux has more than adequate information on installing these programs.
Multi-Tech Systems, Inc. MT5600BA/BL Series User Guide (S000276E)

Appendix F - Pin Descriptions
Appendix F - P - P - P - P - Pin Descr in Descr in Descr in Descr in Descriptions
RS-232 P 232 P 232 P 232 P 232 Pin Descr in Descr in Descr in Descr in Descriptions
Label Pin I/O type Signal name/description
CGND 1 GND CGND is tied common to GND on the modem’s PCB.
TD 2 Transmitted Data The DTE uses the TD line to send data to the modem for transmission over the telephone line or to transmit commands to the modem.
RD 3 Received Data The modem uses the RD line to send data received from the telephone line to the DTE and to send modem responses to the DTE.
RTS 4 Request to Send The RTS signal is used for hardware flow control.
CTS 5 Clear To Send CTS is controlled by the modem to indicate whether or not the modem is ready to transmit data. CTS high indicates to the DTE that signals presented on TD will be transmitted to the telephone line. CTS low indicates to the DTE that it should not transfer data across the interface on TD.
DSR 6 Out Data Set Ready DSR indicates modem status to the DTE. DSR low indicates that the DTE is to disregard all signals appearing on the interchange circuits except Ring Indicator (RI). It reflects the status of the local data set, and does not indicate an actual link with any remote data equipment.
GND 7 GND Ground.
CFLO 8 CD Carrier Detect The modem uses the CD line to signal to the DTE that a carrier has been detected.
+12V 9 A positive voltage output from the modem used for tests or for strapping signals high if needed.
11 NC
12 NC
13 NC
14 NC
TCLK 15 TC Transmit Clock Output from modem, used in synchronous mode.
RCLK 17 RC Receive Clock Output from modem, used in synchronous mode.
V54-2 18 AL Analog Loop Input to modem to enable analog loop test.
DTR 20 DTR Data Terminal Ready Input to modem from DTE to control answering and disconnection of modem.
62 Multi-Tech Systems, Inc. MT5600BA/BL Series User Guide (S000276E)

Appendix F - Pin Descriptions
Label Pin I/O type Signal name/description
RDL 21 RDL Remote Digital Loop Input to modem to enable RDL test.
RI 22 Ring Indicator RI output high indicates the presence of a ring signal on the telephone line.
XCLK 24 XCLK External Clock Input to modem used in special synchronous applications.
TM 25 TM Test Mode Output from modem to indicate modem is in one of the test modes.
RS-232 Cab 232 Cab 232 Cab 232 Cab 232 Cable P le P le P le P le Pinouts
DCE DB-25
TD 2
8 CD 7 GND 6 DSR 5 CTS 4 RTS 3 RD 2 TD
CTS 5 RTS 4
DSR 6
CD 8 GND 7
DTR 20
20 DTR 22 RI
RI 22
Fig. F-1. 25-pin to 25-pin RS-232 cable.
connector DTE DB-9 connector
TD 3
8 CD 7 GND 6 DSR 5 CTS 4 RTS 3 RD 2 TD
CTS 8 RTS 7
DSR 6
CD 1 GND 5
DTR 4 RI 9
20 DTR 22 RI
Fig. F-2. 9-pin to 25-pin RS-232 cable.
63 Multi-Tech Systems, Inc. MT5600BA/BL Series User Guide (S000276E)
connector · connector

Appendix F - Pin Descriptions
DTE Mini-DIN 8-pin connector DCE DB-25
8 CD 7 GND 6 DSR 5 CTS 4 RTS 3 RD 2 TD
6 7 8 3 4 5 1 2
HSKo (RTS) 20 DTR 22 RI
Fig. F-3. Macintosh cable.
Leased Line P ased Line P ased Line P ased Line P ased Line Pinouts
2 3 4 5
To Terminal Block Screws
Fig. F-4. Two-wire leased line cable.
To Terminal Block Screws
Fig. F-5. Four-wire leased line cable.
64 Multi-Tech Systems, Inc. MT5600BA/BL Series User Guide (S000276E)

servicing your modem 47 Set Country Code Using AT
Windows NT 43 Windows operating systems 9–11
Commands 11 Set Country Code Using Global
Wizard 11 Set Country Code Using LCDs 10 solving problems 41–46 specifications, technical 51–52 Status Trunk 15 Store Callback Number command
39 Store Callback Password command
39 Sync/Async Mode command 45 sync/async modes 16, 24
technical specifications 51–52 telephone
connecting a 7 connection 7 line 43 number, dialing 27 number, listing 27 number, storing 27 terminal mode 42 testing the modem 8, 43
loopback tests 27–28 menu options 20 self-test 41 troubleshooting 41–46
UARTs 45 uninstalling a modem from Windows
9 UNIX commands 25 upgrading the modem 57–59
V.25bis 16, 24 V.54 tests 27
warranty 47 Windows 3.1 42, 45 Windows 9x 43
66 Multi-Tech Systems, Inc. MT5600BA/BL Series User Guide (S000276E)
Pages referenced in this manual — manufacturer, support and downloads.
Owners and our team usually reply within a day — and your question helps the next person too.
Be the first to ask — other owners or our team will answer.