Instruction/ maintenance manual of the product UC-7122 Moxa
Go to page of 34
UC-7122/7124 User ’ s Manual Third Edition, May 2009 www .moxa.com/product © 2009 Moxa Inc. All righ ts reserved. Reproducti on without perm ission is pr ohibited.
UC-7122/7124 User’s Manual The software d escribed in thi s manual i s furnished u nder a license agreem ent and m ay be used only in accordance with the term s of that agreement. Copyright Notice Copyright © 2009 Moxa Inc. All rights reserved. Reproducti on without perm ission is pr ohibited.
Table of Contents Chapter 1 Introduction .................................................................................................. 1-1 Overview ..................................................................................................
1 1 Chapter 1 Introduction The UC-712 2/7124 are pocket size em bedded com puters wi th 2 or 4 seri al ports, dual 10/100 Mbps Ethernet, an SD s ocket, and a USB 2.0 host port. The UC-7122/7124 are ideal for front-end device monit oring, data ac quisition, a nd protocol conversio n.
UC-7122/7124 User’s Manual Introduction Overview The UC-712 2/7124 em bedded com puters come wi th 2 or 4 R S-232/422/ 485 serial port s and dual 10/100 Mbps Ethernet LAN ports to provide users with a versatile communication platform, making these RISC-based em bedded com puters ideal for your embedded a pplications.
UC-7122/7124 User’s Manual Introduction UC-7122/7124 Features The UC-712 2/7124 em bedded com puters have the following features: y Cirrus Log ic EP9302 ARM9 32-bit 200 MHz pr ocessor y 32 MB on-board RA M y 16 MB built-in flash memory y RS-232/422/485 se rial ports with software sel ectable interface y Baudrates between 50 bps and 921.
UC-7122/7124 User’s Manual Introduction Power Cons umption (W ithout U SB device plu gged in) UC-7122: 340 mA @ 12 VDC UC-7124: 360 mA @ 12 VDC (With USB device plug ged in) UC-7122: 667 mA @ 12 VDC.
UC-7122/7124 User’s Manual Introduction Networking and Communications Capabilities y Simple Network Management Pr otocol (SNMP) —Monitors rem ote connections to the network. y Simple Network Time Protocol (SNTP) Client —Provides support for sy nchronizing t he device’s syste m time wit h an SNTP server, and supports D aylight Savi ngs Time.
UC-7122/7124 User’s Manual Introduction Obtaining the Firmware Build Version There are tw o ways to obt ain the firm ware version of UC-7122/ 7124 em bedded comput ers. This information is particularly important for identif ying th e features supported by the computer.
UC-7122/7124 User’s Manual Introduction An SD card has its own life cycle. Since m ost SD cards are made from a NAND Flas h, their hardware controllers implement BBM. This featur e a llows FAT to skip bad blocks if they exist. Furthermore, the mem ory space of an SD card is much larger than that of the NOR Flash.
UC-7122/7124 User’s Manual Introduction The following table lists USB m ass storage devi ces that ha ve been tested successfully for compatibility. Vendor Device Name Size CRUZER mini 128 MB Intel F.
2 2 Chapter 2 Getting Started In this chapte r, we expl ain how to u se a PC to ope rate a UC-71 22/7124 em bedded com puter. We will refer to the PC that connects to the UC-7122/71 24 as a development workstation , and the UC-7122/7124 embedded computer will b e called a target computer .
UC-7122/7124 User’s Manual Getting Started Starting Your UC-7122/7124 Computer Connect the SG wire to the shield ed contact located in the uppe r left c orner of t he UC-7122/ 7124 computer, and then power it up by connecting it to the power ad aptor.
UC-7122/7124 User’s Manual Getting Started Step 6: Type “4 ” for “For mat Flas h Disk and Reset OS” and t hen press Enter . Step 7: After a few seconds, you will see the bootloader menu ag ain. Unplug the power line and then plug it back again.
UC-7122/7124 User’s Manual Getting Started Changing the Network Settings The UC-7122/7124 com puter comes with two or four network inte rfaces. The defa ult IP addresses and netmasks of the network interfaces are shown in the following table: Default IP Address Netmas k LAN1 192.
UC-7122/7124 User’s Manual Getting Started After logging on through th e console port or through a Telnet client, a list o f busybox commands are available to operate the com puter. Use “H ELP” t o displ ay all of the c ommands an d type “HELP [comm and name ]” to display e xtended help for the given com mand.
UC-7122/7124 User’s Manual Getting Started Current pa ssword: New password: Retype ne w password: Password has been changed User List: Use the co mmand userlist to list all users.
UC-7122/7124 User’s Manual Getting Started Subnet Mask: 255.255.255.0 Default Gateway: 192.168.27.254 Adapter Name: AX887961 Description: AX887961 Adapter Index: 3 Address: 00 90 e8 00 d1 24 DHCP Enabled: YES DHCP Server: 192.168.1.95 Primary WINS: 192.
UC-7122/7124 User’s Manual Getting Started 2-8 Simple Network Management Protocol (SNMP) SNMP is the st andard Internet protocol for network m anagement, an d belongs to t he TCP/IP protocol s uite. SNMP was developed to monitor and manage net works.
3 3 Chapter 3 Web-based Management System Note: You must use Internet Explorer 5.5 or above to ac cess the web-based management system. The UC-7122/ 7124 ready-t o-run embedded computers a re network-cent ric platform s designed t o be used as fro nt-end com puters for data ac quisition a nd industri al control.
UC-7122/7124 User’s Manual Web-based Management Sy stem Logging onto the Web-based Management System The web-based management syste m installed in the UC-7122 /7124 computer inco rporates often-use d features into C GI pages, an d categorizes them on a menu ba r.
UC-7122/7124 User’s Manual Web-based Management Sy stem Networking/Server Configuration The target com puter has two ne twork interfaces. To view or change the settings , click the Networking item on the menu bar. After the page loads, en ter the relevant details in the correspondin g text fields a nd then cli ck Update to activate the changes.
UC-7122/7124 User’s Manual Web-based Management Sy stem Binary/Text Fi le Managem ent PC users enjoy the conve nience of usin g Windows’ f riendly win dows-based file manager t o browse, delet e, and orga nize files and di rectories.
UC-7122/7124 User’s Manual Web-based Management Sy stem Monitoring and Controlling Processes (Threads) At runtim e, the target com puter ma nages up to 32 a pplications t hat you can m onitor and control with the management system. To view current pro cesses, click the Processes item on the main menu bar.
A A Appendix A Firmware Upgrade Procedure The latest firm ware for M oxa’s embedde d comput ers can be dow nloaded from the down load center on Moxa’s website. For th e UC-7122/7124, we provide a solution to up load the firmware file by TFTP, and upgrade the firmware using boot lo ader utilities.
UC-7122/7124 User’s Manual Firmware Upgrade Procedure 6. Type “2 ” TFTP Config and press “Enter”. This will guide you to th e TFTP configuration menu. 7. Select “2” and then press “Enter”. You will be asked to provide a local IP and server IP.
UC-7122/7124 User’s Manual Firmware Upgrade Procedure 8. After providing both IP addresses, you may check the settings by typing “3” on the co mmand line.
UC-7122/7124 User’s Manual Firmware Upgrade Procedure Upgrading the Firmware 1. From the main menu of the boot load er utility, select “1” for Firmware Upgrade to start the firmware upgra de process. 2. Type “1” to load fi rmware image fr om your PC.
UC-7122/7124 User’s Manual Firmware Upgrade Procedure 3. Press “Enter” and then wait a few seconds for the firmware im age to download. Restart the computer after the file has been downloaded.
B B Appendix B Frequently Asked Questions FAQ 1 Can I change t he connectio n port for t he web serve r (HTTPD) t o somethi ng other than 80? Answer 1 Yes, you can chang e the web server port. For example, suppose that y our embedde d computer’s IP address is 192.
UC-7122/7124 User’s Manual Frequently Asked Ques tions St e p 8 : Log in to the em bedded computer using a T elnet client and then restart the we b server . /> services stop HTP0: /> services start HTP0: St e p 9 : T ry connecting to the server with th e new URL, as follows: http://192.
UC-7122/7124 User’s Manual Frequently Asked Ques tions Answer 8 Y es. Log on to the com puter from a re mote client, and then use t he “reboot” command to reboot the system. FA Q 9 Which USB specificat ions do the embedde d computers sup port? Answer 9 The embedded computers su pport USB 2.
UC-7122/7124 User’s Manual Frequently Asked Ques tions St e p 2 : Enter the full path of the application in the first text field. If there any arguments are required, en ter them in the second text field. Click “Add”. St e p . 3 : Rep eat Steps 1 and 2 if additional applications ne ed to be executed on bootup .
UC-7122/7124 User’s Manual Frequently Asked Ques tions FAQ 12 How do I monitor pr ocesses on the embedde d computer ? Answer 12 From the Telnet/serial console, enter the command “ps” to monito r current processes. The web conso le here is a “Pr ocesses” page.
An important point after buying a device Moxa UC-7122 (or even before the purchase) is to read its user manual. We should do this for several simple reasons:
If you have not bought Moxa UC-7122 yet, this is a good time to familiarize yourself with the basic data on the product. First of all view first pages of the manual, you can find above. You should find there the most important technical data Moxa UC-7122 - thus you can check whether the hardware meets your expectations. When delving into next pages of the user manual, Moxa UC-7122 you will learn all the available features of the product, as well as information on its operation. The information that you get Moxa UC-7122 will certainly help you make a decision on the purchase.
If you already are a holder of Moxa UC-7122, but have not read the manual yet, you should do it for the reasons described above. You will learn then if you properly used the available features, and whether you have not made any mistakes, which can shorten the lifetime Moxa UC-7122.
However, one of the most important roles played by the user manual is to help in solving problems with Moxa UC-7122. Almost always you will find there Troubleshooting, which are the most frequently occurring failures and malfunctions of the device Moxa UC-7122 along with tips on how to solve them. Even if you fail to solve the problem, the manual will show you a further procedure – contact to the customer service center or the nearest service center