Instruction/ maintenance manual of the product DA-660-8-CE Moxa
Go to page of 31
DA-660-8/16-CE User ’ s Manual Fourth Edition, April 2008 www .moxa.com/product © 2008 Moxa Inc ., all rights reserved. Reproducti on without perm ission is prohibit ed.
DA-660-8/16-CE User’s Manual The software d escribed in this m anual is furnis hed under a license agreem ent and may be use d only in accordance with the term s of that agreement. Copyright Notice Copyright © 2008 Moxa Inc. All rights reserved. Reproducti on without perm ission is prohibit ed.
Table of Contents Chapter 1 Introduction .................................................................................................. 1-1 Overview ..................................................................................................
1 1 Chapter 1 Introduction Microsoft® Windows® CE 5.0 is an open, scalable, 3 2-bit operating sy stem (OS) that all ows you to build a wi de range of inn ovative, small footp rint devices.
DA-660-8/16-CE User’s Manual Introduction Overview The DA-660 WinC E embedded computer is ideal for relia ble, small-footpri nt, programmabl e, communicat ion-centric applicat ions. DA-660 uses a n Intel XScale IXP-42 2 RISC-based CPU running at a clock rate of 266 MHz.
DA-660-8/16-CE User’s Manual Introduction Hardware Specifications Model DA-660-8-C E DA-660-16-CE CPU Intel XScale IXP-422 266 MHz RAM 128 MB Flash 32 MB LAN Auto-sensi ng 10/100 Mbps × 2 with b uilt-in 1.
DA-660-8/16-CE User’s Manual Introduction y Component Services (COM and DCOM) —The Common Object M odel (COM) is a n operating sy stem-independe nt, object-oriented sy stem for creati ng binary soft ware components that can inte ract with other COM-ba se d components in the same process space, in other processes , or on remote m achines.
DA-660-8/16-CE User’s Manual Introduction y Web Ser ver (HTTPD) —Includes ASP, ISAPI Secure S ocket Layer support, SSL 2, SSL 3, Transport Layer Sec urity (TLS/SSL 3.1) public key -based protocols, an d Web Administrat ion ISAPI Extensi ons. y Dial-up Netw orking —Consists of a RAS client API and Point to Point Pro tocol (PPP).
DA-660-8/16-CE User’s Manual Introduction 1-6 In addition, the F A T file system searches fo r free space sequentially when performing write operations. As files are deleted, free storage sp ace becomes more and more fra gmented, making it difficult to search.
2 2 Chapter 2 Getting Started In this chapter, we explain how to use a PC to operate a DA-660 c omputer. For clarity, the PC is referred to as a development workstation and t he DA-660 com puter is called a tar get computer.
DA-660-8/16-CE User’s Manual Getting Started Starting Your DA-660 Computer Connect the power cord that is shi pped with the pack age to the AC/DC power connector (located on the right side of the rear panel) of the target computer. It tak es about 30 to 60 seconds for the system to boot up.
DA-660-8/16-CE User’s Manual Getting Started > netconfig -h Usage: netconfig –n <“LAN1” or “LAN2”> [-m <netmask>] [-d <DNS server>] [-g <gateway>] [-i <IP address>] For exam ple, your developm ent workstatio n has a LAN port at 192.
DA-660-8/16-CE User’s Manual Getting Started User/Group Management User Group: You often want the target computer to be accessible by multiple users with different needs. For exam ple, a specific service, such as ft p or telnet, is accessible on ly by the users within the permi ssible group.
DA-660-8/16-CE User’s Manual Getting Started Adjusting System Time and RTC Time The DA-660 com puter has two tim e settings, the system tim e (or CPU clock) and the RTC (Real Time Clock) time. The system time regulates the ex ecution of instructions and the RTC keeps track of the time even when t he com puter is turned off.
DA-660-8/16-CE User’s Manual Getting Started Troubleshooting Network Connectivity The ipconfig tool prints the T CP/IP-related config uration data of a host including t he IP addresses, gateway and DNS server s. > ipconfig /all Windows IP configuration Ethernet adapter Local Area Connection: IP Address: 192.
DA-660-8/16-CE User’s Manual Getting Started 2-7 To add a ro uting item on net work interface 1, > route ADD 192.168.0.0 MASK 255.255.0.0 192.168.
3 3 Chapter 3 Web-based Management System Note: Internet Explorer 5.5 or above is required to use the web based management system. DA-660 ready -to-run embedded c omputers are networ k-centric platform s designed to be used as tion ol atically front-end computers for data acquisition an d industrial control.
DA-660-8/16-CE User’s Manual Web-based Management Sy stem Logging Onto Web-based Management System A web-based ma nagement system is provided for the D A-660-CE for easier m anagement and system adm inistration. The web-based m anagement syst em uses a menu b ar and CGI pages t o provide access to comm only-used features.
DA-660-8/16-CE User’s Manual Web-based Management Sy stem Networking/Server Configuration The target com puter has two ne twork interfaces. To view or change their settings, click the Networking item on the menu bar.
DA-660-8/16-CE User’s Manual Web-based Management Sy stem Process (Thread) Monitoring/Control At runtim e, the target comput er manages up t o 32 applications that you can moni tor and control via the manage ment system . To view current processes, click the Processes item on t he main menu bar.
DA-660-8/16-CE User’s Manual Web-based Management Sy stem Binary/Text File Management On a PC, it i s certainly conve nient to have a friendly windo w-based file manage r to browse, del ete, and organize files and directories. On the target com puter, such a convenient feature is sim ulated by the web- based managem ent system.
A A Appendix A Using the LCM Keypad Da-660 has an LCM and keypad that provid e users with on-site parameter readings, and the ab ility to modify the configuration. Parameters that can be modified incl ude model nam e, firmware version, network settings, etc.
ThinkCore DA-660-8/16-CE User’s Manual Using the LCM Keypad Main Menu Network ↑ Serial Port ↓ Press “ ﹀ " or u se “SEL” to select an item. Serial Port ↑ Console Port ↓ Press “ ﹀ " or us e “SEL” to select an item. Console Port ↑ Return ↓ Press “ ^ "or u se “SEL” to select an item.
B B Appendix B Firmware Upgrade Procedure Software features for Moxa em bedd ed computers continue to be developed, improving quality and enhancing functionality . Firmware updates will be made available in the Moxa download center . When updating the firmware for your em bedd ed computer , follow these instructions: 1.
DA-660-8/16-CE User’s Manual Firmware Upgrade Procedure 5. The upgrade proves should tak e about five minutes. When the process is complete, you will be asked if you wish to keep the current network settings. Press “Y” to keep the current network settings.
DA-660-8/16-CE User’s Manual Firmware Upgrade Procedure 6. Enter “Y” whe n prompted to reboot the embedde d computer . The system will be restarted with the new firmware in effect.
C C Appendix C Frequently Asked Questions Q: Can the connection port for the web server (HTTPD) be change d to something other than 80? A: Y es, you can change the conn ection port for the web server . Th is is accomplished by cha nging a registry setting.
DA-660-8/16-CE User’s Manual Frequently Asked Ques tions St e p 7 . Change the value of “Sock Addr” to “02 00 00 51 00 00 00 00 00 00 00 00 00 00 00 00”. For “Modified V alue:”, enter “02 00 00 51 00 00 00 00 00 0 0 00 00 0 0 00 00 0 0” Go to the di splay position for “SockAddr” an d click “Modify ”.
DA-660-8/16-CE User’s Manual Frequently Asked Ques tions Q: If I accidenta lly delete system files or co rrupt the operating system, is there any way to recover the system or rese t the embedded com.
DA-660-8/16-CE User’s Manual Frequently Asked Ques tions St e p 2 . In the first text field, enter the full path of the app lication. In the second text field, enter any arguments, if required. Click “Add”. St e p 3 . Repeat steps 1 and 2 to set up additional app lications that will start automatically upon bootu p.
DA-660-8/16-CE User’s Manual Frequently Asked Ques tions Q: How do I monitor processes on Moxa embedded computers? A: In the T elnet or serial cons ole, you can execute “ps” t o mon itor current processes. In the web console, there is a “Processes” page .
An important point after buying a device Moxa DA-660-8-CE (or even before the purchase) is to read its user manual. We should do this for several simple reasons:
If you have not bought Moxa DA-660-8-CE yet, this is a good time to familiarize yourself with the basic data on the product. First of all view first pages of the manual, you can find above. You should find there the most important technical data Moxa DA-660-8-CE - thus you can check whether the hardware meets your expectations. When delving into next pages of the user manual, Moxa DA-660-8-CE you will learn all the available features of the product, as well as information on its operation. The information that you get Moxa DA-660-8-CE will certainly help you make a decision on the purchase.
If you already are a holder of Moxa DA-660-8-CE, but have not read the manual yet, you should do it for the reasons described above. You will learn then if you properly used the available features, and whether you have not made any mistakes, which can shorten the lifetime Moxa DA-660-8-CE.
However, one of the most important roles played by the user manual is to help in solving problems with Moxa DA-660-8-CE. Almost always you will find there Troubleshooting, which are the most frequently occurring failures and malfunctions of the device Moxa DA-660-8-CE along with tips on how to solve them. Even if you fail to solve the problem, the manual will show you a further procedure – contact to the customer service center or the nearest service center