20 11 Moxa Inc . A ll rights re served. P/N: 1802031310010 AWK- 3131 Hardware Installation Guide Moxa AirWorks First Edition, February 2011.
- 2 - Overview Moxa's new AWK - 3131 3 - in - 1 industri al wi reless AP /bridg e/clie nt meets the growing need for faster data transmission speeds and w ider coverage by supporting IEEE 80 2.11n technology with a net data rat e of up t o 300 Mbps.
- 3 - • SFP - 1GLHXLC: Small form factor pluggable transceiver w ith 1000BaseLHX , LC, 40 km, 0 to 60°C • SFP - 1GLHXLC - T: Small form factor pluggabl e trans ceiver with 1000BaseLHX , LC, 40 km.
- 4 - ATTENTION For security reasons, we strongly recommend ch anging the password. To do so, select Maintenance Password , and then follow the on - screen instructions. Step 5: Se lect the operation m ode for th e AWK - 31 31 By default, the AWK - 31 3 1’s operation mode is set to AP.
- 5 - Panel Layout of the AWK - 3131 1. Grounding screw 2. Terminal block for PWR1,PWR2, relay, DI1, and DI2 3. Reset button 4. System LEDs: PWR1, PWR2, PoE, FAULT, and STATE LED s 5. LEDs for signal strength 6. WLAN LED 7. Ethernet or Fiber LED 8. RS - 232 console port 9.
- 6 - Mounting Dimensions (unit = mm) DIN - Rail Mounting The aluminum DIN - Rail attachmen t plate should be fixed to the back panel of the AWK - 3131 when you take it out of the box.
- 7 - Wall Mounting (optional) For transportation app lications that require a n EN 50155 certification report, we strongly r ecommend the purchase of the optional AWK- 3131 wallmount kit, whic h has passed E N 50155 testing. Th is wallmount kit is also convenient for other a pplications that requ ire mounting the AWK- 3131 to a wall.
- 8 - WARNING • This equipment is intended to be used in a Restrict ed Access Location, such as a ded icated computer room . A ccess can only be gained by SERVICE PERSONS or by USERS who ha ve been instructed about the fact tha t the metal chassis of the equi pment i s extremely hot and m a y cause burns.
- 9 - ATTENTION This product is inte nded to be supplied by a Listed Power Unit marked “ Class 2 ” or “ LPS ” and rated O/P: 12 to 48 V DC , minim um 6 W (12 V to 48V), 25°C .
- 10 - ATTENTION Before connecting the AWK - 3131 to the DC power inputs, mak e sure the DC power source vo ltage is stable. Wiring the Relay Contact The AWK - 3131 has one relay output, wh ich consists of the t wo contacts of the terminal block on the AWK - 3131 ’s top pane l.
- 11 - Communication Con nections 10/100BaseT(X) Ethern et Port Connection The 10/100BaseT(X) ports located on the AWK- 31 31 ’s front panel are used to connect to Ethernet- enabled devices. Below we show pinouts for both MDI (NIC - type) po rts and MDI -X (HUB/Switch - type) ports.
- 12 - NOTE 1. The pin numbers for ma le DB9 and DB25 conne ctors, and hole numbers for fema le DB9 and DB25 con nectors are labeled on the connecto r. However, the number s are typically quite small, so y ou may need to us e a magnifying glass to see the numbers clearl y.
- 13 - LAN Green/ Amber Amber LAN port’s 10/ 100 Mbps link is active. Amber Blink ing Data is being transmitted at 10/100 Mbps Amber Off LAN port’s 10/ 100 Mbps link is inactive Green LAN port’s 1000 Mbps link is active.
- 14 - TX Transmit Power: 802.11b: 1 to 11 Mbps: Typ. 18 dBm (± 1.5 dBm) 802.11g: 6 to 24 Mbps: Typ. 18 dBm (± 1.5 dBm) 36 to 48 Mbps: Typ. 17 dBm (± 1.5 dBm) 54 Mbps: Typ. 1 5 dBm (± 1.5 dB m) 802.11a: 6 to 24 Mbps: Typ. 17 dBm (± 1.5 dBm) 36 to 48 Mbps: Typ.
- 15 - Alarm Contact: 1 relay output w ith current carry ing capacity of 1 A @ 24 VDC Digital Inputs: 2 electrically isolated inputs • +13 to +30 V for state “1” • +3 to - 30 V for state “0” • Max. input current: 8 mA Physical Characteristics Housing: Metal, IP30 protection Weight: 970 g Dimensions: 53.
- 1 6 - ATTENTION Use the antennas corr ectly: The 2.4 GHz ante nnas are needed when the AWK - 3131 operates in IEEE 802.11b/ g/ n . The 5 GHz antennas are needed fo r IEEE802.11a /n . Make sure your ante nna installation is within a safety area, which is covered by a lightning protection or surge arr est system.
An important point after buying a device Moxa AWK-3131-M12-EU-T (or even before the purchase) is to read its user manual. We should do this for several simple reasons:
If you have not bought Moxa AWK-3131-M12-EU-T yet, this is a good time to familiarize yourself with the basic data on the product. First of all view first pages of the manual, you can find above. You should find there the most important technical data Moxa AWK-3131-M12-EU-T - thus you can check whether the hardware meets your expectations. When delving into next pages of the user manual, Moxa AWK-3131-M12-EU-T you will learn all the available features of the product, as well as information on its operation. The information that you get Moxa AWK-3131-M12-EU-T will certainly help you make a decision on the purchase.
If you already are a holder of Moxa AWK-3131-M12-EU-T, but have not read the manual yet, you should do it for the reasons described above. You will learn then if you properly used the available features, and whether you have not made any mistakes, which can shorten the lifetime Moxa AWK-3131-M12-EU-T.
However, one of the most important roles played by the user manual is to help in solving problems with Moxa AWK-3131-M12-EU-T. Almost always you will find there Troubleshooting, which are the most frequently occurring failures and malfunctions of the device Moxa AWK-3131-M12-EU-T along with tips on how to solve them. Even if you fail to solve the problem, the manual will show you a further procedure – contact to the customer service center or the nearest service center