TECHZONE ™ Ceiling Systems CEILING SYSTEMS [ Between us, ideas become reality . ] ®.
Channel your thinking The T echZone ™ Ceiling Systems provide a monolithic, uncluttered ceiling visual using standard components and organize the look of the space. A six-inch wide technical “zone” organizes services, including lighting, diffusers and sprinklers in a system that’ s pre-qualified for fit and finish.
[ PAGE TWO ] LIGHTING DIFFUSER FIRE PROTECTION T echZone Partners Armstrong has teamed with industry leaders in lighting, air diffusers and fire protection to create T echZone fixtures that are pre-qualified for fit and finish. Look for the Armstrong T echZone Compatible sign of assurance on partner specification sheets.
[ PAGE THREE ] Select your Select your ceiling T echZone Select your module on-center field panel material and size spacing Optima Ultima 4' 4'-0" 4' 4'-6" 4' 6&apos.
[ PAGE FOUR ] Suspension system colors have been coordinated with field panels, technical panels and partner fixtures. Select your field panel edge detail and suspension system (All field panels not available in all edge detail options. See layouts, pg.
Layout configurations T echZone ™ Ceiling Systems offer many configuration options to meet just about any design and functional need. T echZone is engineered for 4' and 5' building modules. T echnical zone on-center spacing can be as narrow as 4' and as wide as 10'-6".
4' on-center technical zone [ 4' BUILDING MODULES ] [ PAGE SIX ] 42" x 48" FIELD PANELS 9/16" Grid Optima Sq. T egular Item #3287 21" x 24" FIELD PANELS 9/16" Grid Optima Sq. T egular Item #3279 24" x 42" FIELD PANELS 9/16" Grid Optima Sq.
4'-6" on-center technical zone [ 4' BUILDING MODULES ] [ PAGE SEVEN ] 48" x 48" FIELD PANELS 15/16" Grid Optima Sq. Lay-in Item #3160 15/16" Grid Optima Sq. T egular Item #3255 9/16" Grid Optima Sq. T egular Item #3256 24" x 24" FIELD PANELS 15/16" Grid Optima Sq.
[ 4' BUILDING MODULES ] 6'-6" on-center technical zone 7'-6" on-center technical zone [ PAGE EIGHT ] 42" x 48" FIELD PANELS 9/16" Grid Optima Sq. T egular Item #3287 24" x 72" FIELD PANELS 15/16" Grid Optima Sq.
[ 4' BUILDING MODULES ] 8'-6" on-center technical zone 48" x 48" FIELD PANELS 15/16" Grid Optima Sq. Lay-in Item #3160 15/16" Grid Optima Sq. T egular Item #3255 9/16" Grid Optima Sq. T egular Item #3256 24" x 96" FIELD PANELS 15/16" Grid Optima Sq.
[ PAGE TEN ] Optima 30" x 30" T egular field panels and Metal T egular technical panels on Suprafine suspension system. Neo-Ray recessed light fixtures.
5' on-center technical zone 30" x 54" FIELD PANELS 9/16" Grid Optima Sq. T egular Item #3284 20" x 54" FIELD PANELS 9/16" Grid Optima Sq. T egular Item #3276 27" x 30" FIELD PANELS 9/16" Grid Optima Sq.
[ PAGE TWEL VE ] 5'-6" on-center technical zone [ 5' BUILDING MODULES ] 20" x 60" FIELD PANELS 15/16" Grid Optima Sq. Lay-in Item #3156 15/16" Grid Optima Sq. T egular Item #3278 9/16" Grid Optima Sq. T egular Item #3277 30" x 60" FIELD PANELS 15/16" Grid Optima Sq.
[ PAGE THIRTEEN ] Optima 48" x 48" T egular field panel and Optima Lay-In technical panels on Suprafine suspension system. Lithonia recessed light fixtures.
10'-6" on-center technical zone 8' on-center technical zone [ 5' BUILDING MODULES ] 20" x 60" FIELD PANELS 15/16" Grid Optima Sq. Lay-in Item #3156 15/16" Grid Optima Sq. T egular Item #3278 9/16" Grid Optima Sq.
T echZone ™ Field Panels KEY SELECTION A TTRIBUTES ■ Nondirectional DuraBrite ® surface for excellent durability and superior light reflectance (reduces lighting and energy costs by up to 23%) ■ Optima - Outstanding acoustical performance for open plan areas, both Articulation Class (180-190) and NRC (0.
Stabilizer Clip for Optima, Item 435 Recommended for panels 5' and greater in length. Ordered separately . Note: Panels 5' to 8' – One clip installed near the mid-point of each long edge.
[ PAGE SEVENTEEN ] T echZone partners Industry-leading suppliers have engineered and designed lighting, diffusers and fire protection products for use in T echZone ™ Ceiling Systems. All Armstrong T echZone compatible products are qualified for fit and finish with T echZone Ceiling Systems.
[ PAGE EIGHTEEN ] LIGHTING RECESSED FIXTURES ■ 6" x 48" and 6" x 60" ■ Lay-in and T egular Edges ■ 9/16" and 15/16" grid compatible RECESSED DOWNLIGHTS ■ 3.
CEILING SYSTEMS [ Between us, ideas become reality . ] ® T echLine SM / 1 877 ARMSTRONG 1 877 276 7876 armstrong.com/ceilings 10% post consumer waste.
An important point after buying a device Armstrong World Industries TechZone (or even before the purchase) is to read its user manual. We should do this for several simple reasons:
If you have not bought Armstrong World Industries TechZone yet, this is a good time to familiarize yourself with the basic data on the product. First of all view first pages of the manual, you can find above. You should find there the most important technical data Armstrong World Industries TechZone - thus you can check whether the hardware meets your expectations. When delving into next pages of the user manual, Armstrong World Industries TechZone you will learn all the available features of the product, as well as information on its operation. The information that you get Armstrong World Industries TechZone will certainly help you make a decision on the purchase.
If you already are a holder of Armstrong World Industries TechZone, but have not read the manual yet, you should do it for the reasons described above. You will learn then if you properly used the available features, and whether you have not made any mistakes, which can shorten the lifetime Armstrong World Industries TechZone.
However, one of the most important roles played by the user manual is to help in solving problems with Armstrong World Industries TechZone. Almost always you will find there Troubleshooting, which are the most frequently occurring failures and malfunctions of the device Armstrong World Industries TechZone along with tips on how to solve them. Even if you fail to solve the problem, the manual will show you a further procedure – contact to the customer service center or the nearest service center