Please read and keep these instructions

getting the best from your new cleaner...
Please study all instructions carefully before use.
Using the steamer • When using the steamer, always keep it vertical.
For replacement parts, help with using your Morphy Richards product, problems and lots more, contact us by phone or through our website.

The use of any electrical appliance requires the following common sense safety rules.
Primarily there is danger of injury or death and secondly the danger of damage to the appliance. These are indicated in the text by the following two conventions:
Other safety considerations
Check that the voltage on the rating plate of your appliance corresponds with your house electricity which must be A.C. (alternating current).
If the socket outlets in your home are not suitable for the plug supplied with this

appliance, the plug should be removed and the appropriate one fitted.
Should the fuse in the 13 amp plug require changing, a 13 amp BS1362 fuse must be fitted.
 Ê
È
Á
Î
Í
Features
Accessories you should have
„ Funnel ‰ Filling jug  Round brush Ê Jet nozzle Á Directional nozzle Ë Cotton socks (3 of) È Upholstery nozzle Í Window squeegee attachment Î Carrying strap • Storage bag (not shown)
⁄ Heater switch ¤ ‘Heater on’ indicator light ‹ Filler cap › Flexible hose fi Hose end fl Carry strap fixing locations ‡ Carrying handle · Cord storage ‚ Hose end storage holder

heater switch ⁄ to the on position D. The boiler will take approximately 5 minutes to heat up.
Please remember that the steam cleaner operates by emitting steam at an increased temperature of 115
oC. Never use it on objects or surfaces which cannot resist this temperature, delicate materials, dralon, plastic, natural fur etc. Where any doubt exists, check carefully on a part of the material where minor marks will not matter.
1 To fill, unscrew the filler cap ‹ anti-clockwise B. 2 Fill the boiler with a maximum of 1 litre of water by using the funnel and the filler jug provided C. Three full jugs make up the 1 litre required. WARNING: Do not overfill. • Do not use any detergent. 3 WARNING: Screw the filler cap clockwise to tighten. Tighten fully.
Heater switch
When the steam flow begins to slow, the unit is ready for refilling. 1 Switch off the cleaner before refilling. 2 Unplug from the mains socket and leave for a few minutes to cool.
1 When the water tank has been filled, insert the plug into the power socket. 2 Fit the required nozzle/accessory. 3 Switch the cleaner on by pressing the
WARNING: Allow any steam to disperse away before attempting to remove the filler cap. 3 Carefully unscrew the cap. WARNING: Take care as the inner part of the cap will be hot. 4 Use warm water to reduce heat-up time. Refill using the funnel and the jug. • The water tank should be emptied after use. Allow to cool completely before emptying.
C D

The following accessories can be added onto the jet nozzle by simply pushing to fit:
2 Directional nozzle Push the directional nozzle onto the jet nozzle F.
The directional nozzle Á is ideal for getting steam into awkward spaces and for directing steam under the lip of sink/toilet bowls, grout, tap ware, venetian blinds, and sliding door runners.
3 The round brush Push the round brush onto the jet nozzle G.
The round brush  is ideal for hob cleaning and tile grouting depending on the application.
1 Jet nozzle Attach the jet nozzle Ê to the hose end fiby lining up the lugs and twisting to lock in place E.
The closer you hold the jet nozzle to the surface to be cleaned, the better the cleaning results.
G
F
H

5 Cotton socks Stretch the sock over the upholstery attachment I.
Switch on the steam and move the sock covered brush gently over surfaces to be cleaned. Replace sock regularly so that more dirt can be collected and to avoid too much moisture being applied. Extra socks can be ordered by using our helpline.
Sanitising and removing dust mites and allergens from bedding and upholstery
Fit the upholstery nozzle and pass the steam slowly and evenly over the surface ensuring all areas are treated. Repeat the process. Leave the mattress to dry thoroughly before covering.
6 Window squeegee attachment Attach the window squeegee attachment Í to the upholstery nozzle by attaching the hooks on the upholstery nozzle to the tabs on the window squeegee and push the main tab over the upholstery nozzle J.
Your steam cleaner comes with a carrying strap for added convenience.
The carrying strap Î can be clipped on the fixing locations fleither side of the cleaner K.
This accessory is ideal for cleaning windows, patio doors, conservatory glass, tiles and shower screens.
To clean windows, start at the top of the window, pressing the squeegee to the surface and drag downwards. Move the squeegee in straight passes from top to bottom. Wipe the rubber blade and the bottom edge of the window dry after each pass.
I K

1 Switch the cleaner off and unplug from the socket. Wait until the cleaner has cooled down completely. 2 Empty the water tank. Allow the inside of the water tank to dry out before replacing filler cap.
Your cleaner is manufactured to withstand normal day-to-day use, but an occasional wipe over with a damp cloth will help maintain its good looks. Abrasive cleaners should not be used.
Regularly rinse the water tank to release any limescale deposits that have collected on the bottom of the tank. Use clean cold water and fit the filler cap to allow vigorous rinsing.
If you have any difficulty with your appliance, do not hesitate to call us. We are likely to be more help than the store from where it was bought.
If the ‘heater on’ light goes off before the cleaner starts to steam, this indicates the thermostat has operated too soon and the cleaner needs descaling.
In order to prolong the life of your cleaner, you should descale the boiler at least every 6 months. 1 Switch the cleaner off, unplug and allow to cool. 2 Empty any water out of the tank. 3 Mix the descaler in the measuring jug using warm water. We recommend using 50gm of citric acid crystals per 1 litre of water. Citric acid crystals are available from most pharmacies. 4 Pour 1 litre of the descaler solution into the tank. 5 Fit the cap and tighten fully. 6 Using the handle, move the steam cleaner about to swill the solution around the tank. 7 Leave for 30 minutes. 8 Empty the solution carefully. 9 Rinse the tank with clean warm water, then empty. 10 Wipe the outside of the cleaner with a damp cloth to remove all traces of descaler solution.
UK Helpline 0845 077 7700 Ireland Helpline 1800 409 119
For electrical products sold within the European Community. At the end of the electrical products useful life it should not be disposed of with household waste. Please recycle where facilities exist. Check with your Local Authority or retailer for recycling advice in your country.

To qualify for the 2 year guarantee, the appliance must have been used according to the manufacturer’s instructions. For example, the product must have been regularly descaled, as instructed.
It is important to retain the retailer’s receipt as proof of purchase. Staple your receipt to this back cover for future reference.
Please quote the following information if the product develops a fault. These numbers can be found on the back of the product.
Model no. Serial no.
All Morphy Richards products are individually tested before leaving the factory. In the unlikely event of any appliance proving to be faulty within 28 days of purchase, it should be returned to the place of purchase for it to be replaced.
If the fault develops after 28 days and within 24 months of original purchase, you should contact the Helpline number quoting Model number and Serial number on the product, or write to Morphy Richards at the address shown. You will be asked to return the product (in secure, adequate packaging) to the address below, along with a copy of proof of purchase. Subject to the exclusions set out below (1-5), the faulty appliance will then be repaired or replaced and dispatched usually within 7 working days of receipt.
If for any reason this item is replaced during the 2 year guarantee period, the guarantee on the new item will be calculated from original purchase date. Therefore it is vital to retain your original till receipt or invoice to indicate the date of initial purchase.
Morphy Richards products are intended for household use only.
The After Sales Division Registered address Morphy Richards Ltd, Mexborough South Yorkshire, England, S64 8AJ
Morphy Richards has a policy of continuous improvement in product quality and design. The company, therefore reserves the right to change the specification of its models at any time.
Helpline (office hours) UK 0845 077 7700 Republic of Ireland 1800 409 119
VC70455 MUK Rev 1 08/07
Pages referenced in this manual — manufacturer, support and downloads.
Owners and our team usually reply within a day — and your question helps the next person too.
Be the first to ask — other owners or our team will answer.