Page 1 of the Moen 4400 user manual — CAUTION:
Page 1 · click to enlarge
Page 1

4200, 4220, 4330, 4340, 4350, 4400, 4641, 4643 SERIES

MT123A

Moen 4400 — 4200, 4220, 4330, 4340, 4350, 4400, 4641, 4643 SERIES diagram (page 1)
Fig. 1

LEFT WITH HOMEOWNER

LAVATORY FAUCETS

Four-Inch Centerset

LEVER HANDLE KNOB HANDLE

Moen 4400 — LEVER HANDLE KNOB HANDLE diagram (page 1)
Fig. 2

With clamp bar, spacer and mounting nut installed, tilt clamp bar back as shown, then drop faucet supplies down through deck holes and tighten from below. On decks thicker than 3/4" you may have to remove spacer.

Fits 4" centers and through a 1" minimum diameter hole.

Complies with ASME A112.18.1M and CSA B125

CAUTION:

Always turn water off before disassembling the valve. Open valve handle to alleviate water pressure to insure that complete water shut-off has been accomplished. Before turning water on during either rough-in or trim-out, make sure that the cartridge retainer clip is in place. The cartridge and retainer clip were properly installed and tested before leaving the factory. Although it is unlikely, it is nevertheless possible that through the handling of the valve by any number of persons the retainer clip may not be properly installed. This should be carefully checked at time of rough-in and trim-out. If the retainer clip is not properly installed, water pressure could force the cartridge out of the casting. Personal injury or water damage to the premises could result.

Clip · Ear

Page 2 of the Moen 4400 user manual — MT123A
Page 2 · click to enlarge
Page 2

Installation

Be sure lavatory or mounting surface is clean and dry. Place a bead of plumber's putty around the inside lip of the gasket. Lay gasket on deck and place faucet supplies and studs down through deck holes. Position faucet. Fasten faucet to deck, using clamp bars, spacers (if necessary), and mounting nuts on studs. Tighten. Engage tailpiece nuts on supplies to faucet nipples. Tighten nuts.

HOLD WITH

FAUCET CONNECTION

WRENCH

NIPPLE

WARNING: Hold the faucet connection nipples with a wrench when

tightening to prevent twisting and collapse of the tubing.

NUT

Flushing IMPORTANT:

TIGHTEN

Pipe chips, sand, stones and other solids found in new and renovated plumbing can damage the sealing surface of the faucet cartridge and cause a leak. To avoid damage, DO NOT OPERATE VALVE until you have followed these instruc- tions:

a. Make sure all water supplies are OFF. b. Remove handle parts, stop tube, retainer clip and cartridge (see "Disassembly" for detailed instructions). c. At the supplies, slowly turn both hot and cold water on and thoroughly flush out the body and lines.

Lift Rod & Waste Assembly

(For model with grid strainer assembly follow steps 1-3 only)

LIFT ROD AND KNOB

1. Thoroughly clean around drain opening in lavatory basin. Apply 1/4 inch bead of plumber's putty (not furnished) around the underside of seat (as shown). 2. Apply pipe joint compound or Teflon tape (not furnished) to top threaded end of the drain body. Slip drain body up through the drain opening and screw seat on the drain body. 3. Position the drain body (with pivot rod opening extending rear- ward) and tighten mounting nut until the drain body is snug. Wipe excess plumber's putty from the seat area. Apply pipe joint compound (not furnished) to top threaded end of tailpipe and screw into the drain body. Tighten firmly by hand. 4. Position the drain plug in either of the following ways: A. VANDALPROOF - This design is to prevent unauthorized removal of the drain plug. Unscrew the pivot nut and remove the pivot rod. Inside the drain body position the pivot rod through the drain plug hole as shown in the illustration below. Screw the pivot nut back on the drain body. DO NOT OVERTIGHTEN. B. EASY REMOVAL - This design is for quick removal of drain plug for cleaning. Just drop in the drain plug as shown in the illustration below.

BASIN

DRAIN

PLUG

VANDALPROOF

HOLE

LIFT ROD

STRAP SCREW

SEAT

PIPE JOINT COMPOUND

OR TEFLON

PLUMBERS

TAPE (NOT FURNISHED)

LIFT ROD

PUTTY MAX 2-1/2"

STRAP

MIN 1-1/2"

BOTTOM GASKET

FLAT WASHER

MOUNTING

NUT

SPRING

CLIP

DRAIN

BODY

PIPE JOINT COMPOUND

PIVOT NUT

(NOT FURNISHED)

PIVOT ROD

SEAT

B. EASY REMOVAL A. VANDALPROOF

TAILPIPE

PIVOT

ROD

POSITION FOR EASY REMOVAL

PIVOT

ROD VANDALPROOF

PIVOT

ROD

POSITION

5. Hook up lift rod and knob, lift rod strap and spring clamp as shown. 6. With the drain plug in full open position, adjust lift rod and knob to clear faucet and tighten lift rod strap screw.

MT123A

Show 4 more labels / short text on this page
2-1/8" · 1-1/2" · 8" · 1-1/4"
Page 3 of the Moen 4400 user manual — Cleaning & Care Instructions for
Page 3 · click to enlarge
Page 3

Disassembly

For Knob Models: 1. Remove handle cover, handle screw, knob, stop tube, washer, and retainer clip.

For Concentrix Handle Models: 1. Remove handle cover, gasket, handle screw, handle insert, handle skirt, handle adapter, stop tube, and retainer clip.

For Lever Handle Models: 1. Remove handle cap and handle screw. Lift handle assembly up, keeping cartridge stem in down position and tilt up and off. Remove clip retainer ring and retainer clip. Slide off grooved sleeve and spacer.

For All Models: 2. Using pliers, grasp the cartridge stem and pull out the cartridge. If cartridge is difficult to remove, turn the cartridge shell back and forth with the Moen cartridge wrench (furnished with the new Moen cartridge) or use a Moen cartridge puller.

Moen 4400 — Disassembly diagram (page 3)
Fig. 3 · Disassembly

Reassembly

Fully insert the cartridge until the top of the cartridge ears are level with the top of the faucet body. Position the cartridge ears up and down to allow insertion of the retainer clip. The notched flat on the stem must point UP when mounting Knob or Concentrix Handles, DOWN for Lever Handle models. Replace the retainer clip (for lever handles replace spacer, grooved sleeve, retainer clip, and clip retainer ring) so that the legs straddle the cartridge ears and slide down into the bottom slot in the body. This prevents the cartridge from rotating and locks it in the body. Reinstall handle parts. Tighten handle screw securely. Press on handle cover. For Concentrix models install handle insert onto adapter (align locator notch on handle insert with key on adapter). NOTE: Locator notch on the handle insert must be on the bottom. Fit gasket up into handle cover recess. Replace handle cover and hand tighten.

Moen 4400 — Reassembly diagram (page 3)
Fig. 4 · Reassembly

To Eliminate Cross-Piping on Back-To-Back Installations, or To Correct Reversed Rough-In Where Hot and Cold Positions Are Reversed

Remove handle parts and stop tube (see "Disassembly"). Turn cartridge stem around so that the notched flat is turned one half turn or 180°. Reinstall handle parts. Tighten handle screw securely; replace handle cover.

Cleaning & Care Instructions for

Special Finish Models:

All that is necessary to clean these faucets is to wipe them with a soft, damp cloth such as terrycloth. Warm water will remove dry water spots. CAUTION: DO NOT use cleansers which contain abrasives or harsh chemicals. NEVER use alcohol or other organic solvents. A high quality, non abrasive wax polish applied occasionally will help to preserve the deep tones of the finish.

Page 4 of the Moen 4400 user manual — ®
Page 4 · click to enlarge
Page 4

Consumer Information

Faucets made of leaded brass alloys may contribute small amounts of lead to water that is allowed to stand in contact with the brass. The amount of lead contributed by any faucet is highest when the faucet is new. The following steps may reduce potential exposure to lead from faucets and other parts of the plumbing system:

  • Always run the water for a few seconds prior to use for drinking or cooking.
  • Use only cold water for drinking or cooking.
  • If you wish to flush the entire plumbing system of water that has been standing in the pipes or other fittings, run the cold water until the temperature of the water drops, indicating water coming from the outside main.
  • If you are concerned about lead in your water, have your water tested by a certified laboratory in your area.

HELPLINE:

For answers to any product, installation, replacment parts or warranty questions, call our consumer helplines.

In the U.S., toll free: 1-800-321-6636

In Canada call: Toronto, 905-829-3400 Rest of Canada, 1-800-465-6130

®

© Copyright 1995 Moen Incorporated

Moen Incorporated 25300 Al Moen Drive, North Olmsted, OH 44070-8022, U.S.A.

In CanadaMoen Inc. 2816 Bristol Circle, Oakville, Ontario L6H5S7 MT123A SEP 95

Printed in U.S.A.

Ask about the Moen 4400

Owners and our team usually reply within a day — and your question helps the next person too.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
No questions yet about the Moen 4400

Be the first to ask — other owners or our team will answer.

Original document

Moen 4400 manual PDF

4 pages·49 KB·Plumbing Product·PDF
Click any page above to open it here
Page 1 / …
100%
Loading pages…