unit (mm (in.)
accountable, lost business opportunities or unrealized gain on the customer's side resulting from failure of the
product, or any other damage, secondary disaster, accident, damage to equipment other than the product or
disruption of other business operations arising out of special circumstances which may or may not have been
z This product is manufactured as a general-purpose product intended for general industrial use only. It is not
z This product is manufactured under our strict quality control system. However, if the product is used in the
intended facility in such a way that a failure of the product may lead to serious accident or loss, incorporate
10th Floor, Manulife Tower, 169 Electric Road, North Point, HongKong
3F Block5 Building Automation Instrumentation Plaza 103 Cao Bao Rd.
z If you are considering to use this product in equipment or systems for nuclear power generation, power
generation, aerospace, medical or passenger transport applications, consult our sales representatives.
6F., No.105 Wu-Kung 3rd.RD, Wu-Ku Hsiang, Taipei Hsine, Taiwan
In the offset/gain setting mode, confirm that the RUN LED is flickering, and then set the offset/gain.
27.4 (1.08)
Mitsubishi Electric shall not be liable for any loss caused by reasons for which Mitsubishi is not held
China Ryoden Automation Shanghai Ltd.
Korea HAN NEUNG TECHNO CO.,LTD.
Taiwan Setsuyo Enterprise Co., Ltd.
Setting of the offset/gain setting mode differs for function version A and function version B.
IN 24VDC
0- ± 10V
Hong Kong Ryoden Automation Ltd.
D/A
designed nor manufactured for use in an equipment or system affecting human lives.
If the RUN LED is not flickering, check whether switch 4 is set correctly.
98 (3.36)
backup or fail-safe functions into the system design.
500 Corporate Woods Parkway Vernon Hills, IL 60061
Germany Mitsubishi Electric Europe B.V. German
Spain Mitsubishi Electric Europe B.V. Spanish
Tripswitch Drive, Elandsfontein Gauteng,
Brazil MELCO-TEC Rep. Com.e Assessoria
Edificio Paraiso Trade Center-8 andar
Gothaer Strasse 8 D-40880 Ratingen,
Travellers Lane, Hatfield, Herts., AL10
Italy Mitsubishi Electric Europe B.V. Italian
Centro Dir. Colleoni, Pal. Perseo-Ingr.2
France Mitsubishi Electric Europe B.V. French
U.S.A Mitsubishi Electric Automation Inc.
U.K Mitsubishi Electric Europe B.V. UK
Via Paracelso 12, 20041 Agrate B.,
25 Boulevard des Bouvets, F-92741 Nanterre Cedex, France
South Africa Circuit Breaker Industries LTD.
Paraiso, Sao Paulo, SP Brazil
08190 Sant Cugat del Valles, Barcelona, Spain
Rua Correia Dias, 184,
Carretera de Rubi 76-80
90 (3.54)
For safe use of the product
Tecnica Ltda.
predicted at Mitsubishi.
Warranty
*1 *2 Motor drive module, etc.
terminal This is the terminal for connecting the 24 V DC external power supply.
(2) Tighten the terminal screws for the module to the specified torque shown below.
(1) Use separate cables for the external output signal or external power supply for
settings for the GX Developer. It can be easy to set by inputting using hexadecimal-4

Switch No. 5 of the intelligent function module has been
the AC and D/A converter modules. Take steps to prevent the AC side from
The settings for the intelligent function module are performed using the I/O allocation
Insufficient tightening torque could result in shorts, failures or malfunction.
(2) Ground one point of the shield for shielded wires or shielded cables.
Switch 5 0 : Fixed * Setting any value within the setting range will provide the same operation. When the setting range is 1 to FH, set 1 for example.
Module mounting screw (M3 screw) 0.36 to 0.48 N · m Terminal block terminal screw (M3 screw) 0.42 to 0.58 N · m Terminal block mounting screw (M3.5 screw) 0.66 to 0.89 N · m
(1) Do not drop the module or cause it to receive strong impact.
or online module change enabled
set to a value other than zero "0".
00H 01 to FFH (numeric value other than 00H)*
being affected by surge or inductance.
0H 1 to FH (numeric value other than 0H)*
1 to FH (numeric value other than 0H)*
5.2 External wiring
5. Wiring
digits.
This section explains the names of the components for the D/A conversion module.

When incorporating the Mitsubishi PLC into other machinery or equipment and keeping
mode High resolution mode
0 to 5 V 1.25 mV 0.416 mV 1 to 5 V 0 to 4000 1.0 mV 0 to 12000 0.333 mV – 10 to 10 V 2.5 mV – 16000 to
16000 0.625 mV
4000 0.75 mV – 12000 to 12000 0.333 mV
Conformance to the EMC Directive/Low Voltage Directive
Q62DA, Q64DA
D/A Converter Module
User's Manual
(Hardware)
IB-0800033-F (0706) MEE
When using Mitsubishi equipment, thoroughly read this manual and the associated
manuals introduced in the manual. Also pay careful attention to safety and handle the
These precautions apply only to Mitsubishi equipment. Refer to the user’s manual of the
cause superficial to medium injury, or physical damage only, if
Depending on circumstances, procedures indicated by CAUTION may also be linked
Thank you for buying the Mitsubishi general-purpose programmable logic
CAUTION Procedures which may lead to a dangerous condition and
Using this PLC in an environment outside the range of the general specifications may cause
Improper installation may result in malfunction , breakdown or the module coming loose and
If the screws are tightened too much, it may cause damage to the screw and/or the module,
If the terminal screws are tightened too much, it may cause damage to the screw and/or the
Before operating the system, be sure to remove the film to provide adequate heat ventilation.
cause death or serious injury if not carried out properly.
Store this manual in a safe place so that you can take it out and read it whenever
D/A Converter Module User's Manual SH-080054
Number 13JQ49
CPU module to use for a description of the PLC system safety precautions.
The following manuals are also related to this product. Order them if necessary.
electric shock, fire, malfunction, and damage to or deterioration of the product.
They should be installed 100 mm (3.94 inch) or more from each other.
Securely fix the module with screws if it is subject to vibration during use.
There is a risk of electric shock if the terminal cover is not attached.
In any case, it is important to follow the directions for usage.
Not doing so could result in noise that may cause malfunction.
CAUTION
CAUTION
CAUTION
and familiarize yourself with the product.
not carried out properly.
Do not remove this film until the wiring is complete.
necessary. Always forward it to the end user.
resulting in fallout, short circuits or malfunction.
Not doing so may cause damage to the module.
module, resulting in short circuits or malfunction.
controller MELSEC Q Series.
[WIRING PRECAUTIONS]
"DANGER" and "CAUTION".
the external device.
module properly.
to serious results.
dropping.
failure.