SAFETY PRECAUTIONSp.2REVISIONSp.12INTRODUCTIONp.13CONTENTSp.13About Manualsp.151. OVERVIEWp.181.1 Overviewp.181.2 Featuresp.201.2.1 Features of Motion CPUp.201.2.2 Basic specifications of Q173DCPU/Q172DCPUp.221.3 Hardware Configurationp.251.3.1 Motion system configurationp.251.3.2 Q173DCPU System overall configurationp.271.3.3 Q172DCPU System overall configurationp.291.3.4 Software packagesp.311.3.5 Restrictions on motion systemsp.342. MULTIPLE CPU SYSTEMp.382.1 Multiple CPU Systemp.382.1.1 Overviewp.382.1.2 Installation position of CPU modulep.392.1.3 Precautions for using I/O modules and intelligent function modulesp.402.1.4 Modules subject to installation restrictionsp.412.1.5 How to reset the Multiple CPU systemp.422.1.6 Operation for CPU module stop errorp.432.2 Starting Up the Multiple CPU Systemp.462.2.1 Startup Flow of the Multiple CPU Systemp.462.3 Communication between the PLC CPU and the Motion CPU in the Multiple CPU Systemp.482.3.1 CPU shared Memoryp.482.3.2 Multiple CPU high speed transmissionp.512.3.3 Multiple CPU high speed refresh functionp.622.3.4 Clock synchronization between Multiple CPUp.662.3.5 Multiple CPU synchronous startupp.672.3.6 Control Instruction from PLC CPU to Motion CPUp.683. COMMON PARAMETERSp.703.1 System Settingsp.703.1.1 System data settingsp.713.1.2 Common system parametersp.733.1.3 Individual parametersp.793.2 I/O number assignmentp.843.2.1 I/O number assignment of each modulep.843.2.2 I/O number of each CPU modulesp.863.2.3 I/O number settingp.873.3 Servo Parametersp.884. AUXILIARY AND APPLIED FUNCTIONSp.924.1 Limit Switch Output Functionp.924.1.1 Operationsp.924.1.2 Limit output setting datap.954.2 Absolute Position Systemp.994.2.1 Current value controlp.1014.3 High-Speed Reading of Specified Datap.1024.4 ROM Operation Functionp.1034.4.1 Specifications of 7-segment LED/Switchesp.1034.4.2 Outline of ROM operationp.1054.4.3 Operating procedure of the ROM operation functionp.1104.5 Security Functionp.1124.5.1 Password registration/changep.1124.5.2 Password deletep.1144.5.3 Password checkp.1154.5.4 Password savep.1164.6 All clear functionp.1174.7 Communication via Networkp.1184.7.1 Specifications of the communications via networkp.1184.7.2 Access range of the communications via networkp.1194.8 Monitor Function of the Main Cyclep.1244.9 Servo Parameter Reading Functionp.1254.10 Optional Data Monitor Functionp.1264.11 Connect/Disconnect Functionp.1274.12 Remote operationp.1324.12.1 Remote RUN/STOPp.1324.12.2 Remote latch clearp.134APPENDICESp.136APPENDIX 1 Special relays/Special registersp.136APPENDIX 1.1 Special relaysp.136APPENDIX 1.2 Special registersp.140APPENDIX 1.3 Replacement of special relays/special registersp.146APPENDIX 2 System Setting Errorsp.148APPENDIX 3 Self-diagnosis error codep.150APPENDIX 4 Differences Between Q173DCPU/Q172DCPU and Q173HCPU/Q172HCPUp.161APPENDIX 4.1 Differences Between Q173DCPU/Q172DCPU and Q173HCPU/Q172HCPUp.161APPENDIX 4.2 Comparison of devicesp.163APPENDIX 4.3 Differences of each modep.170WARRANTYp.171
Page 1 of the Mitsubishi Electronics Q172DCPU user manual — INDUSTRIAL AUTOMATION
Page 1 · click to enlarge
Page 1

MITSUBISHI ELECTRIC

Motion Controllers

Programming Manual

Common

Q173DCPU Q172DCPU

01 01 2008 B(NA)-0300134 Version A

INDUSTRIAL AUTOMATION

MITSUBISHI ELECTRIC

Page 2 of the Mitsubishi Electronics Q172DCPU user manual — A - 1
Page 2 · click to enlarge
Page 2

SAFETY PRECAUTIONS

(Please read these instructions before using this equipment.)

Before using this product, please read this manual and the relevant manuals introduced in this manual carefully and pay full attention to safety to handle the product correctly. These precautions apply only to this product. Refer to the Q173DCPU/Q172DCPU Users manual for a description of the Motion controller safety precautions. In this manual, the safety instructions are ranked as "DANGER" and "CAUTION".

Indicates that incorrect handling may cause hazardous conditions, resulting in death or severe injury.

DANGER

Indicates that incorrect handling may cause hazardous conditions, resulting in medium or slight personal injury or physical damage.

CAUTION

Depending on circumstances, procedures indicated by CAUTION may also be linked to serious results. In any case, it is important to follow the directions for usage.

Please save this manual to make it accessible when required and always forward it to the end user.

A - 1

Page 3 of the Mitsubishi Electronics Q172DCPU user manual — A - 2
Page 3 · click to enlarge
Page 3

For Safe Operations 1. Prevention of electric shocks DANGER

Never open the front case or terminal covers while the power is ON or the unit is running, as this

may lead to electric shocks. Never run the unit with the front case or terminal cover removed. The high voltage terminal and

charged sections will be exposed and may lead to electric shocks. Never open the front case or terminal cover at times other than wiring work or periodic

inspections even if the power is OFF. The insides of the Motion controller and servo amplifier are charged and may lead to electric shocks.

Completely turn off the externally supplied power used in the system before mounting or removing the

module, performing wiring work, or inspections. Failing to do so may lead to electric shocks. When performing wiring work or inspections, turn the power OFF, wait at least ten minutes, and

then check the voltage with a tester, etc.. Failing to do so may lead to electric shocks. Be sure to ground the Motion controller, servo amplifier and servomotor. (Ground resistance :

100 or less) Do not ground commonly with other devices. The wiring work and inspections must be done by a qualified technician. Wire the units after installing the Motion controller, servo amplifier and servomotor. Failing to do

so may lead to electric shocks or damage. Never operate the switches with wet hands, as this may lead to electric shocks. Do not damage, apply excessive stress, place heavy things on or sandwich the cables, as this

may lead to electric shocks. Do not touch the Motion controller, servo amplifier or servomotor terminal blocks while the power

is ON, as this may lead to electric shocks. Do not touch the built-in power supply, built-in grounding or signal wires of the Motion controller

and servo amplifier, as this may lead to electric shocks.

2. For fire prevention CAUTION

Install the Motion controller, servo amplifier, servomotor and regenerative resistor on

incombustible. Installing them directly or close to combustibles will lead to fire. If a fault occurs in the Motion controller or servo amplifier, shut the power OFF at the servo

amplifier’s power source. If a large current continues to flow, fire may occur. When using a regenerative resistor, shut the power OFF with an error signal. The regenerative

resistor may abnormally overheat due to a fault in the regenerative transistor, etc., and may lead to fire. Always take heat measures such as flame proofing for the inside of the control panel where the

servo amplifier or regenerative resistor is installed and for the wires used. Failing to do so may lead to fire. Do not damage, apply excessive stress, place heavy things on or sandwich the cables, as this may

lead to fire.

A - 2

Page 4 of the Mitsubishi Electronics Q172DCPU user manual — A - 3
Page 4 · click to enlarge
Page 4

3. For injury prevention CAUTION

Do not apply a voltage other than that specified in the instruction manual on any terminal.

Doing so may lead to destruction or damage. Do not mistake the terminal connections, as this may lead to destruction or damage. Do not mistake the polarity ( + / - ), as this may lead to destruction or damage. Do not touch the heat radiating fins of controller or servo amplifier, regenerative resistor and

servomotor, etc., while the power is ON and for a short time after the power is turned OFF. In this timing, these parts become very hot and may lead to burns. Always turn the power OFF before touching the servomotor shaft or coupled machines, as these

parts may lead to injuries. Do not go near the machine during test operations or during operations such as teaching.

Doing so may lead to injuries.

4. Various precautions

Strictly observe the following precautions.

Mistaken handling of the unit may lead to faults, injuries or electric shocks. (1) System structure

CAUTION

Always install a leakage breaker on the Motion controller and servo amplifier power source. If installation of an electromagnetic contactor for power shut off during an error, etc., is specified in

the instruction manual for the servo amplifier, etc., always install the electromagnetic contactor. Install the emergency stop circuit externally so that the operation can be stopped immediately and

the power shut off. Use the Motion controller, servo amplifier, servomotor and regenerative resistor with the correct

combinations listed in the instruction manual. Other combinations may lead to fire or faults. Use the CPU module, base unit and motion module with the correct combinations listed in the

instruction manual. Other combinations may lead to faults. If safety standards (ex., robot safety rules, etc.,) apply to the system using the Motion controller,

servo amplifier and servomotor, make sure that the safety standards are satisfied. Construct a safety circuit externally of the Motion controller or servo amplifier if the abnormal

operation of the Motion controller or servo amplifier differ from the safety directive operation in the system. In systems where coasting of the servomotor will be a problem during the forced stop, emergency

stop, servo OFF or power supply OFF, use dynamic brakes. Make sure that the system considers the coasting amount even when using dynamic brakes. In systems where perpendicular shaft dropping may be a problem during the forced stop,

emergency stop, servo OFF or power supply OFF, use both dynamic brakes and electromagnetic brakes.

A - 3

Page 5 of the Mitsubishi Electronics Q172DCPU user manual — A - 4
Page 5 · click to enlarge
Page 5

CAUTION

The dynamic brakes must be used only on errors that cause the forced stop, emergency stop, or

servo OFF. These brakes must not be used for normal braking. The brakes (electromagnetic brakes) assembled into the servomotor are for holding applications,

and must not be used for normal braking. The system must have a mechanical allowance so that the machine itself can stop even if the

stroke limits switch is passed through at the max. speed. Use wires and cables that have a wire diameter, heat resistance and bending resistance

compatible with the system. Use wires and cables within the length of the range described in the instruction manual. The ratings and characteristics of the parts (other than Motion controller, servo amplifier and

servomotor) used in a system must be compatible with the Motion controller, servo amplifier and servomotor. Install a cover on the shaft so that the rotary parts of the servomotor are not touched during

operation. There may be some cases where holding by the electromagnetic brakes is not possible due to the

life or mechanical structure (when the ball screw and servomotor are connected with a timing belt, etc.). Install a stopping device to ensure safety on the machine side.

(2) Parameter settings and programming

CAUTION

Set the parameter values to those that are compatible with the Motion controller, servo amplifier,

servomotor and regenerative resistor model and the system application. The protective functions may not function if the settings are incorrect. The regenerative resistor model and capacity parameters must be set to values that conform to

the operation mode, servo amplifier and servo power supply module. The protective functions may not function if the settings are incorrect. Set the mechanical brake output and dynamic brake output validity parameters to values that are

compatible with the system application. The protective functions may not function if the settings are incorrect. Set the stroke limit input validity parameter to a value that is compatible with the system

application. The protective functions may not function if the setting is incorrect. Set the servomotor encoder type (increment, absolute position type, etc.) parameter to a value

that is compatible with the system application. The protective functions may not function if the setting is incorrect. Set the servomotor capacity and type (standard, low-inertia, flat, etc.) parameter to values that

are compatible with the system application. The protective functions may not function if the settings are incorrect. Set the servo amplifier capacity and type parameters to values that are compatible with the

system application. The protective functions may not function if the settings are incorrect.

A - 4

Page 6 of the Mitsubishi Electronics Q172DCPU user manual — A - 5
Page 6 · click to enlarge
Page 6

CAUTION

Use the program commands for the program with the conditions specified in the instruction

manual. Set the sequence function program capacity setting, device capacity, latch validity range, I/O

assignment setting, and validity of continuous operation during error detection to values that are compatible with the system application. The protective functions may not function if the settings are incorrect. Some devices used in the program have fixed applications, so use these with the conditions

specified in the instruction manual. The input devices and data registers assigned to the link will hold the data previous to when

communication is terminated by an error, etc. Thus, an error correspondence interlock program specified in the instruction manual must be used. Use the interlock program specified in the intelligent function module's instruction manual for the

program corresponding to the intelligent function module.

(3) Transportation and installation

CAUTION

Transport the product with the correct method according to the mass. Use the servomotor suspension bolts only for the transportation of the servomotor. Do not

transport the servomotor with machine installed on it. Do not stack products past the limit. When transporting the Motion controller or servo amplifier, never hold the connected wires or

cables. When transporting the servomotor, never hold the cables, shaft or detector. When transporting the Motion controller or servo amplifier, never hold the front case as it may fall

off. When transporting, installing or removing the Motion controller or servo amplifier, never hold the

edges. Install the unit according to the instruction manual in a place where the mass can be withstood. Do not get on or place heavy objects on the product. Always observe the installation direction. Keep the designated clearance between the Motion controller or servo amplifier and control panel

inner surface or the Motion controller and servo amplifier, Motion controller or servo amplifier and other devices. Do not install or operate Motion controller, servo amplifiers or servomotors that are damaged or

that have missing parts. Do not block the intake/outtake ports of the Motion controller, servo amplifier and servomotor with

cooling fan. Do not allow conductive matter such as screw or cutting chips or combustible matter such as oil

enter the Motion controller, servo amplifier or servomotor.

A - 5

Page 7 of the Mitsubishi Electronics Q172DCPU user manual — A - 6
Page 7 · click to enlarge
Page 7

CAUTION

The Motion controller, servo amplifier and servomotor are precision machines, so do not drop or

apply strong impacts on them. Securely fix the Motion controller, servo amplifier and servomotor to the machine according to

the instruction manual. If the fixing is insufficient, these may come off during operation. Always install the servomotor with reduction gears in the designated direction. Failing to do so

may lead to oil leaks. Store and use the unit in the following environmental conditions.

EnvironmentConditions Motion controller/Servo amplifierServomotor Ambient temperatureAccording to each instruction manual.0°C to +40°C (With no freezing) (32°F to +104°F) Ambient humidityAccording to each instruction manual.80% RH or less (With no dew condensation) Storage temperatureAccording to each instruction manual.-20°C to +65°C (-4°F to +149°F) AtmosphereIndoors (where not subject to direct sunlight). No corrosive gases, flammable gases, oil mist or dust must exist Altitude1000m (3280.84ft.) or less above sea level VibrationAccording to each instruction manual

When coupling with the synchronous encoder or servomotor shaft end, do not apply impact such

as by hitting with a hammer. Doing so may lead to detector damage. Do not apply a load larger than the tolerable load onto the synchronous encoder and servomotor

shaft. Doing so may lead to shaft breakage. When not using the module for a long time, disconnect the power line from the Motion controller

or servo amplifier. Place the Motion controller and servo amplifier in static electricity preventing vinyl bags and store. When storing for a long time, please contact with our sales representative.

Also, execute a trial operation.

A - 6

Page 8 of the Mitsubishi Electronics Q172DCPU user manual — A - 7
Page 8 · click to enlarge
Page 8

(4) Wiring

CAUTION

Correctly and securely wire the wires. Reconfirm the connections for mistakes and the terminal

screws for tightness after wiring. Failing to do so may lead to run away of the servomotor. After wiring, install the protective covers such as the terminal covers to the original positions. Do not install a phase advancing capacitor, surge absorber or radio noise filter (option FR-BIF)

on the output side of the servo amplifier. Correctly connect the output side (terminal U, V, W). Incorrect connections will lead the

servomotor to operate abnormally. Do not connect a commercial power supply to the servomotor, as this may lead to trouble. Do not mistake the direction of the surge absorbing diode

installed on the DC relay for the control signal output of brake signals, etc. Incorrect installation may lead to signals not being output when trouble occurs or the protective functions not functioning. Do not connect or disconnect the connection cables between

VIN (24VDC)

Control output signal RA

each unit, the encoder cable or PLC expansion cable while the power is ON.

Securely tighten the cable connector fixing screws and fixing mechanisms. Insufficient fixing may

lead to the cables combing off during operation. Do not bundle the power line or cables.

(5) Trial operation and adjustment

CAUTION

Confirm and adjust the program and each parameter before operation. Unpredictable

movements may occur depending on the machine. Extreme adjustments and changes may lead to unstable operation, so never make them. When using the absolute position system function, on starting up, and when the Motion

controller or absolute value motor has been replaced, always perform a home position return.

A - 7

Servo amplifier

Page 9 of the Mitsubishi Electronics Q172DCPU user manual — A - 8
Page 9 · click to enlarge
Page 9

(6) Usage methods

CAUTION

Immediately turn OFF the power if smoke, abnormal sounds or odors are emitted from the Motion

controller, servo amplifier or servomotor. Always execute a test operation before starting actual operations after the program or

parameters have been changed or after maintenance and inspection. Do not attempt to disassemble and repair the units excluding a qualified technician whom our

company recognized. Do not make any modifications to the unit. Keep the effect or electromagnetic obstacles to a minimum by installing a noise filter or by using

wire shields, etc. Electromagnetic obstacles may affect the electronic devices used near the Motion controller or servo amplifier. When using the CE Mark-compliant equipment, refer to the "EMC Installation Guidelines" (data

number IB(NA)-67339) for the Motion controllers and refer to the corresponding EMC guideline information for the servo amplifiers, inverters and other equipment. Use the units with the following conditions.

ItemConditions Q61P-A1Q61P-A2Q61PQ62PQ63PQ64P Input power100 to 120VAC +10% -15% (85 to 132VAC)200 to 240VAC+10% -15% (170 to 264VAC)100 to 240VAC+10% -15% (85 to 264VAC)24VDC+30% -35% (15.6 to 31.2VDC)100 to 120VAC+10% / -15% +10% 200 to 240VAC -15% (85 to 132VAC/ 170 to 264VAC) Input frequency50/60Hz ±5% Tolerable momentary power failure20ms or less

A - 8

Page 10 of the Mitsubishi Electronics Q172DCPU user manual — A - 9
Page 10 · click to enlarge
Page 10

(7) Corrective actions for errors

CAUTION

If an error occurs in the self diagnosis of the Motion controller or servo amplifier, confirm the

check details according to the instruction manual, and restore the operation. If a dangerous state is predicted in case of a power failure or product failure, use a servomotor

with electromagnetic brakes or install a brake mechanism externally. Use a double circuit construction so that the electromagnetic brake operation circuit can be

operated by emergency stop signals set externally.

Shut off with the emergency stop signal(EMG).

Shut off with servo ON signal OFF, alarm, electromagnetic brake signal.

RA1 EMG

24VDC

If an error occurs, remove the cause, secure the safety and then resume operation after alarm

release. The unit may suddenly resume operation after a power failure is restored, so do not go near the

machine. (Design the machine so that personal safety can be ensured even if the machine restarts suddenly.)

(8) Maintenance, inspection and part replacement

CAUTION

Perform the daily and periodic inspections according to the instruction manual. Perform maintenance and inspection after backing up the program and parameters for the Motion

controller and servo amplifier. Do not place fingers or hands in the clearance when opening or closing any opening. Periodically replace consumable parts such as batteries according to the instruction manual. Do not touch the lead sections such as ICs or the connector contacts.

Before touching the module, always touch grounded metal, etc. to discharge static electricity from

human body. Failure to do so may cause the module to fail or malfunction. Do not directly touch the module's conductive parts and electronic components.

Touching them could cause an operation failure or give damage to the module. Do not place the Motion controller or servo amplifier on metal that may cause a power leakage

or wood, plastic or vinyl that may cause static electricity buildup.

Do not perform a megger test (insulation resistance measurement) during inspection.

A - 9

Servomotor · Electro- magnetic brakes

Page 11 of the Mitsubishi Electronics Q172DCPU user manual — A - 10
Page 11 · click to enlarge
Page 11

CAUTION

When replacing the Motion controller or servo amplifier, always set the new module settings

correctly. When the Motion controller or absolute value motor has been replaced, carry out a home position

return operation using one of the following methods, otherwise position displacement could occur.

1. After writing the servo data to the Motion controller using programming software, switch on the power again, then perform a home position return operation. 2) Using the backup function of the programming software, load the data backed up before replacement. After maintenance and inspections are completed, confirm that the position detection of the

absolute position detector function is correct.

Do not drop or impact the battery installed to the module.

Doing so may damage the battery, causing battery liquid to leak in the battery. Do not use the dropped or impacted battery, but dispose of it. Do not short circuit, charge, overheat, incinerate or disassemble the batteries. The electrolytic capacitor will generate gas during a fault, so do not place your face near the

Motion controller or servo amplifier. The electrolytic capacitor and fan will deteriorate. Periodically replace these to prevent secondary

damage from faults. Replacements can be made by our sales representative.

(9) About processing of waste

When you discard Motion controller, servo amplifier, a battery (primary battery) and other option articles, please follow the law of each country (area).

CAUTION

This product is not designed or manufactured to be used in equipment or systems in situations that can affect or endanger human life. When considering this product for operation in special applications such as machinery or systems

used in passenger transportation, medical, aerospace, atomic power, electric power, or submarine repeating applications, please contact your nearest Mitsubishi sales representative. Although this product was manufactured under conditions of strict quality control, you are strongly

advised to install safety devices to forestall serious accidents when it is used in facilities where a breakdown in the product is likely to cause a serious accident.

(10) General cautions

CAUTION

All drawings provided in the instruction manual show the state with the covers and safety partitions removed to explain detailed sections. When operating the product, always return the covers and partitions to the designated positions, and operate according to the instruction manual.

A - 10

Page 12 of the Mitsubishi Electronics Q172DCPU user manual — © 2008 MITSUBISHI ELECTRIC CORPORATION
Page 12 · click to enlarge
Page 12

REVISIONS

The manual number is given on the bottom left of the back cover. Print Date Manual Number Revision Jan., 2008 IB(NA)-0300134-A First edition

Japanese Manual Number IB(NA)-0300126

This manual confers no industrial property rights or any rights of any other kind, nor does it confer any patent licenses. Mitsubishi Electric Corporation cannot be held responsible for any problems involving industrial property rights which may occur as a result of using the contents noted in this manual.

© 2008 MITSUBISHI ELECTRIC CORPORATION

A - 11

Page 13 of the Mitsubishi Electronics Q172DCPU user manual — Table of Contents
Page 13 · Contents
Contents

Contents

SAFETY PRECAUTIONSp.2REVISIONSp.12INTRODUCTIONp.13CONTENTSp.13About Manualsp.151. OVERVIEWp.181.1 Overviewp.181.2 Featuresp.201.2.1 Features of Motion CPUp.201.2.2 Basic specifications of Q173DCPU/Q172DCPUp.221.3 Hardware Configurationp.251.3.1 Motion system configurationp.251.3.2 Q173DCPU System overall configurationp.271.3.3 Q172DCPU System overall configurationp.291.3.4 Software packagesp.311.3.5 Restrictions on motion systemsp.342. MULTIPLE CPU SYSTEMp.382.1 Multiple CPU Systemp.382.1.1 Overviewp.382.1.2 Installation position of CPU modulep.392.1.3 Precautions for using I/O modules and intelligent function modulesp.402.1.4 Modules subject to installation restrictionsp.412.1.5 How to reset the Multiple CPU systemp.422.1.6 Operation for CPU module stop errorp.432.2 Starting Up the Multiple CPU Systemp.462.2.1 Startup Flow of the Multiple CPU Systemp.462.3 Communication between the PLC CPU and the Motion CPU in the Multiple CPU Systemp.482.3.1 CPU shared Memoryp.482.3.2 Multiple CPU high speed transmissionp.512.3.3 Multiple CPU high speed refresh functionp.622.3.4 Clock synchronization between Multiple CPUp.662.3.5 Multiple CPU synchronous startupp.672.3.6 Control Instruction from PLC CPU to Motion CPUp.683. COMMON PARAMETERSp.703.1 System Settingsp.703.1.1 System data settingsp.713.1.2 Common system parametersp.733.1.3 Individual parametersp.793.2 I/O number assignmentp.843.2.1 I/O number assignment of each modulep.843.2.2 I/O number of each CPU modulesp.863.2.3 I/O number settingp.873.3 Servo Parametersp.884. AUXILIARY AND APPLIED FUNCTIONSp.924.1 Limit Switch Output Functionp.924.1.1 Operationsp.924.1.2 Limit output setting datap.954.2 Absolute Position Systemp.994.2.1 Current value controlp.1014.3 High-Speed Reading of Specified Datap.1024.4 ROM Operation Functionp.1034.4.1 Specifications of 7-segment LED/Switchesp.1034.4.2 Outline of ROM operationp.1054.4.3 Operating procedure of the ROM operation functionp.1104.5 Security Functionp.1124.5.1 Password registration/changep.1124.5.2 Password deletep.1144.5.3 Password checkp.1154.5.4 Password savep.1164.6 All clear functionp.1174.7 Communication via Networkp.1184.7.1 Specifications of the communications via networkp.1184.7.2 Access range of the communications via networkp.1194.8 Monitor Function of the Main Cyclep.1244.9 Servo Parameter Reading Functionp.1254.10 Optional Data Monitor Functionp.1264.11 Connect/Disconnect Functionp.1274.12 Remote operationp.1324.12.1 Remote RUN/STOPp.1324.12.2 Remote latch clearp.134APPENDICESp.136APPENDIX 1 Special relays/Special registersp.136APPENDIX 1.1 Special relaysp.136APPENDIX 1.2 Special registersp.140APPENDIX 1.3 Replacement of special relays/special registersp.146APPENDIX 2 System Setting Errorsp.148APPENDIX 3 Self-diagnosis error codep.150APPENDIX 4 Differences Between Q173DCPU/Q172DCPU and Q173HCPU/Q172HCPUp.161APPENDIX 4.1 Differences Between Q173DCPU/Q172DCPU and Q173HCPU/Q172HCPUp.161APPENDIX 4.2 Comparison of devicesp.163APPENDIX 4.3 Differences of each modep.170WARRANTYp.171
Page 15 of the Mitsubishi Electronics Q172DCPU user manual — A - 14
Page 15 · click to enlarge
Page 15

About Manuals

The following manuals are also related to this product.

In necessary, order them by quoting the details in the tables below.

Related Manuals (1) Motion controller

Manual Name Manual Number

Q173DCPU/Q172DCPU Motion controller User's Manual

This manual explains specifications of the Motion CPU modules, Q172DLX Servo external signal interface

IB-0300133

module, Q172DEX Synchronous encoder interface module, Q173DPX Manual pulse generator interface

(1XB927)

module, Power supply modules, Servo amplifiers, SSCNET cables, Synchronous encoder cables and

others.

Q173DCPU/Q172DCPU Motion controller (SV13/SV22) Programming Manual (Motion SFC)

IB-0300135

This manual explains the functions, programming, debugging, error lists and others for Motion SFC.

(1XB929)

Q173DCPU/Q172DCPU Motion controller (SV13/SV22) Programming Manual (REAL MODE)

IB-0300136

This manual explains the servo parameters, positioning instructions, device lists, error lists and others.

(1XB930)

Q173DCPU/Q172DCPU Motion controller (SV22) Programming Manual (VIRTUAL MODE)

This manual explains the dedicated instructions to use the synchronous control by virtual main shaft,

IB-0300137

mechanical system program create mechanical module, servo parameters, positioning instructions, device

(1XB931)

lists, error lists and others.

A - 14

Show 5 more labels / short text on this page
(Model Code) · (Optional) · (Optional) · (Optional) · (Optional)
Page 16 of the Mitsubishi Electronics Q172DCPU user manual — A - 15
Page 16 · click to enlarge
Page 16

(2) PLC

Manual Name Manual Number

QCPU User's Manual (Hardware Design, Maintenance and Inspection)

This manual explains the specifications of the QCPU modules, power supply modules, base modules,

SH-080483ENG

(13JR73)

extension cables, memory card battery and others.

QCPU User's Manual (Function Explanation, Program Fundamentals)

This manual explains the functions, programming methods and devices and others to create programs

SH-080484ENG

(13JR74)

with the QCPU.

QCPU User's Manual (Multiple CPU System)

This manual explains the functions, programming methods and cautions and others to construct the

SH-080485ENG

(13JR75)

Multiple CPU system with the QCPU.

QCPU (Q Mode)/QnACPU Programming Manual (Common Instructions)

This manual explains how to use the sequence instructions, basic instructions, application instructions and

SH-080039

(13JF58)

micro computer program.

QCPU (Q Mode)/QnACPU Programming Manual (PID Control Instructions)

SH-080040

This manual explains the dedicated instructions used to exercise PID control.

(13JF59)

QCPU (Q Mode)/QnACPU Programming Manual (SFC)

This manual explains the system configuration, performance specifications, functions, programming,

SH-080041

debugging, error codes and others of MELSAP3.

(13JF60)

I/O Module Type Building Block User's Manual

This manual explains the specifications of the I/O modules, connector, connector/terminal block

SH-080042

(13JL99)

conversion modules and others.

Manual Name Manual Number

MR-J3- B Servo amplifier Instruction Manual

SH-030051

This manual explains the I/O signals, parts names, parameters, start-up procedure and others for

(1CW202)

MR-J3- B Servo amplifier.

Fully Closed Loop Control MR-J3- B-RJ006 Servo amplifier Instruction Manual

This manual explains the I/O signals, parts names, parameters, start-up procedure and others for Fully

SH-030056

(1CW304)

Closed Loop Control MR-J3- B-RJ006 Servo amplifier.

A - 15

Show 12 more labels / short text on this page
(Model Code) · (Optional) · (Optional) · (Optional) · (Optional) · (Optional) · (Optional) · (Optional) · (3) Servo amplifier · (Model Code) · (Optional) · (Optional)
Page 17 of the Mitsubishi Electronics Q172DCPU user manual — A - 16
Page 17 · click to enlarge
Page 17

MEMO

A - 16

Page 18 of the Mitsubishi Electronics Q172DCPU user manual — 1 OVERVIEW
Page 18 · click to enlarge
Page 18

1 OVERVIEW

1. OVERVIEW

1.1 Overview

This programming manual describes the common items of each operating system software, such as the Multiple CPU system of the operating system software packages "SW8DNC-SV Q " for Motion CPU module (Q173DCPU/Q172DCPU).

In this manual, the following abbreviations are used.

Q173DCPU/Q172DCPU or Motion CPU (module) Q173DCPU/Q172DCPU Motion CPU module

Q172DLX Servo external signals interface module/ Q172DEX Serial Synchronous encoder interface module(Note-1)/ Q173DPX Manual pulse generator interface module

Q172DLX/Q172DEX/Q173DPX or Motion module

MR-J3- B Servo amplifier model MR-J3- B

AMP or Servo amplifier General name for "Servo amplifier model MR-J3- B"

QCPU, PLC CPU or PLC CPU module QnUD(H)CPU

Multiple CPU system or Motion system Abbreviation for "Multiple PLC system of the Q series"

CPUn Abbreviation for "CPU No.n (n= 1 to 4) of the CPU module for the Multiple CPU system"

Self CPU Motion CPU being programmed by the currently open MT Developer project

Programming software package General name for MT Developer/GX Developer/MR Configurator

Operating system software General name for "SW8DNC-SV Q "

SV13 Operating system software for conveyor assembly use (Motion SFC) : SW8DNC -SV13Q

SV22 Operating system software for automatic machinery use (Motion SFC) : SW8DNC -SV22Q

MT Developer Abbreviation for "Motion controller programming software MT Developer2 (Version 1.00A or later)"

GX Developer Abbreviation for "MELSEC PLC programming software package GX Developer (Version 8.48A or later)"

MR Configurator Abbreviation for "Servo setup software package MR Configurator (Version C0 or later)"

Manual pulse generator or MR-HDP01 Abbreviation for "Manual pulse generator (MR-HDP01)"

Serial absolute synchronous encoder or Q170ENC Abbreviation for "Serial absolute synchronous encoder (Q170ENC)"

SSCNET (Note-2) High speed synchronous network between Motion controller and servo amplifier

Absolute position system General name for "system using the servomotor and servo amplifier for absolute position"

Battery holder unit Battery holder unit (Q170DBATC)

External battery General name for "Q170DBATC" and "Q6BAT"

Intelligent function module Abbreviation for "MELSECNET/H module/Ethernet module/CC-Link module/ Serial communication module"

(Note-1) : Q172DEX can be used in SV22.

(Note-2)SSCNET: Servo System Controller NETwork

Generic term/Abbreviation Description

Page 19 of the Mitsubishi Electronics Q172DCPU user manual — SV22
Page 19 · click to enlarge
Page 19

1 OVERVIEW

REMARK

For information about the each module, design method for program and parameter, refer to the following manuals relevant to each module.

Motion CPU module/Motion unit Q173DCPU/Q172DCPU User’s Manual

PLC CPU, peripheral devices for PLC program design, I/O

modules and intelligent function module Manual relevant to each module

Operation method for MT Developer Help of each software

  • Design method for Motion SFC program

Q173DCPU/Q172DCPU Motion controller (SV13/SV22)

  • Design method for Motion SFC parameter

Programming Manual (Motion SFC)

  • Motion dedicated PLC instruction

SV13/SV22 • Design method for positioning control

program in the real mode

Q173DCPU/Q172DCPU Motion controller (SV13/SV22)

  • Design method for positioning control

Programming Manual (REAL MODE)

SV22

  • Design method for mechanical system

Q173DCPU/Q172DCPU Motion controller (SV22)

Programming Manual (VIRTUAL MODE)

Show 4 more labels / short text on this page
Item Reference Manual · parameter · (Virtual mode) · program
Page 20 of the Mitsubishi Electronics Q172DCPU user manual — (2) High speed operation processing
Page 20 · click to enlarge
Page 20

1 OVERVIEW

1.2 Features

The Motion CPU and Multiple CPU system have the following features. 1.2.1 Features of Motion CPU

(1) Q series PLC Multiple CPU system

(a) Load distribution of processing can be performed by controlling the

complicated servo control with Motion CPU and the machine control or information control with PLC CPU. Therefore, the flexible system configuration can be realized.

(b) The Motion CPU and PLC CPU are selected flexibly, and the Multiple CPU

system up to 4 CPU modules can be realized. The Motion CPU module for the number of axis to be used can be selected.

Q173DCPUUp to 32 axes Q172DCPU : Up to 8 axes

The PLC CPU module for the program capacity to be used can be selected. (One or more PLC CPU is necessary with the Multiple CPU system.)

Q03UDCPU30k steps Q04UDHCPU : 40k steps Q06UDHCPU : 60k steps

(c) The device data access of the Motion CPU and the Motion SFC program

start can be executed from PLC CPU by the Motion dedicated PLC instruction.

(2) High speed operation processing

(a) The minimum operation cycle of the Motion CPU is made 0.44[ms], and it

correspond with high frequency operation.

(b) High speed PLC control is possible by the universal model QCPU.

Q03UDCPU20[ns] Q04UDHCPU : 9.5[ns] Q06UDHCPU : 9.5[ns]

(For LD instruction)

Page 21 of the Mitsubishi Electronics Q172DCPU user manual — (4) The operating system software package for your application needs
Page 21 · click to enlarge
Page 21

1 OVERVIEW

(3) Connection between the Motion controller and servo amplifier with

high speed synchronous network by SSCNET (a) High speed synchronous network by SSCNET connect between the

Motion controller and servo amplifier, and batch control the charge of servo parameter, servo monitor and test operation, etc. It is also realised reduce the number of wires.

(b) The maximum distance between the Motion CPU and servo amplifier, servo

amplifier and servo amplifier of the SSCNET cable on the same bus was set to 50(164.04)[m(ft.)], and the flexibility improved at the Motion system design.

(4) The operating system software package for your application needs

By installing the operating system software for applications in the internal flash memory of the Motion CPU, the Motion controller suitable for the machine can be realized. And, it also can correspond with the function improvement of the software package.

(a) Conveyor assembly use (SV13)

Offer liner interpolation, circular interpolation, helical interpolation, constant- speed control, speed control, fixed-pitch feed and etc. by the dedicated servo instruction. Ideal for use in conveyors and assembly machines.

(b) Automatic machinery use (SV22)

Provides synchronous control and offers electronic cam control by mechanical support language. Ideal for use in automatic machinery.

Page 22 of the Mitsubishi Electronics Q172DCPU user manual — (2) SV13/SV22 Motion control specifications/performance
Page 22 · click to enlarge
Page 22

1 OVERVIEW

1.2.2 Basic specifications of Q173DCPU/Q172DCPU

(1) Module specifications

Mitsubishi Electronics Q172DCPU — 1 OVERVIEW diagram (page 22)
Fig. 1

Exterior dimensions [mm(inch)] 98 (3.85)(H) 27.4 (1.08)(W) 119.3 (4.69)(D)

(2) SV13/SV22 Motion control specifications/performance

specifications (a) Motion control specifications

Mitsubishi Electronics Q172DCPU — (2) SV13/SV22 Motion control specifications/performance diagram (page 22)
Fig. 2 · (2) SV13/SV22 Motion control specifications/performa…

Number of control axes Up to 32 axes Up to 8 axes

Interpolation functions Linear interpolation (Up to 4 axes), Circular interpolation (2 axes),

PTP(Point to Point) control, Speed control, Speed-position control, Fixed-pitch feed,

Constant speed control, Position follow-up control, Speed control with fixed position stop,

Speed switching control, High-speed oscillation control, Synchronous control (SV22)

Programming language Motion SFC, Dedicated instruction, Mechanical support language (SV22)

Proximity dog type (2 types), Count type (3 types), Data set type (2 types), Dog cradle type,

(Home position return re-try function provided, home position shift function provided)

operation function Possible to connect 12 modules Possible to connect 8 modules

Page 23 of the Mitsubishi Electronics Q172DCPU user manual — 1 OVERVIEW
Page 23 · click to enlarge
Page 23

1 OVERVIEW

Motion control specifications (continued)

Absolute position system Made compatible by setting battery to servo amplifier.

(Possible to select the absolute data method or incremental method for each axis)

(Note-1) 2 systems 1 system

Q172DLX4 modules usable Q172DLX : 1 module usable
Q172DEX6 modules usable Q172DEX : 4 modules usable Motion related interface
(Note-2) Q173DPX3 modules usable
Q173DPX4 modules usable

(Note-1) : The servo amplifiers for SSCNET cannot be used.

(Note-2) : When using the incremental synchronous encoder (SV22 use), you can use above number of modules.

When connecting the manual pulse generator, you can use only 1 module.

Show 5 more labels / short text on this page
Item Q173DCPU Q172DCPU · Number of SSCNET · systems · module · (Note-2)
Page 24 of the Mitsubishi Electronics Q172DCPU user manual — 1 OVERVIEW
Page 24 · click to enlarge
Page 24

1 OVERVIEW

(b) Motion SFC Performance Specifications

Code total (Motion SFC chart + Operation control + Transition)

543k bytes Motion SFC program capacity

Text total (Operation control + Transition) 484k bytes

Number of Motion SFC programs 256 (No.0 to 255)

Motion SFC chart size/program Up to 64k bytes (Included Motion SFC chart comments)

Number of Motion SFC steps/program Up to 4094 steps

Number of selective branches/branch 255

Number of parallel branches/branch 255

Parallel branch nesting Up to 4 levels

Number of operation control programs 4096 with F(Once execution type) and FS(Scan execution type) combined. (F/FS0 to F/FS4095)

Number of transition programs 4096(G0 to G4095)

Operation control program (F/FS) / Transition program (G)

Code size/program Up to approx. 64k bytes (32766 steps)

Number of blocks(line)/program Up to 8192 blocks (in the case of 4 steps(min)/blocks)

Number of characters/block Up to 128 (comment included)

Number of operand/block Up to 64 (operand: constants, word device, bit devices)

( ) nesting/block Up to 32 levels

Operation control program Calculation expression/bit conditional expression

Descriptive expression Transition program Calculation expression/bit conditional expression/

Number of multi execute programs Up to 256

Number of multi active steps Up to 256 steps/all programs

Normal task Execute in main cycle of Motion CPU

Fixed cycle Execute in fixed cycle (0.88ms, 1.77ms, 3.55ms, 7.11ms, 14.2ms)

Event task (Execution can be masked.)

Execute when input ON is set among interrupt module QI60

(16 points).

PLC interrupt Execute with interrupt instruction (D(P).GINT) from PLC CPU.

NMI task Execute when input ON is set among interrupt module QI60

(16 points).

Internal relays (M) 8192 points

Link relays (B) 8192 points

Annunciators (F) 2048 points

Number of devices (Device In the Motion CPU only) (Included the positioning dedicated device)

Special relays (SM) 2256 points

Data registers (D) 8192 points

Link registers (W) 8192 points

Special registers (SD) 2256 points

Motion registers (#) 8736 points

Coasting timers (FT) 1 point (888µs)

Multiple CPU area devices (U \G) Up to 14336 points usable

(Note): Usable number of points changes according to the system settings.

Show 7 more labels / short text on this page
Item Q173DCPU/Q172DCPU · Motion SFC program · comparison conditional expression · Execute specification · Executed task · External interrupt · (Note)
Page 25 of the Mitsubishi Electronics Q172DCPU user manual — (1) Equipment configuration in Q173DCPU/Q172DCPU system
Page 25 · click to enlarge
Page 25

1 OVERVIEW

1.3 Hardware Configuration

This section describes the Q173DCPU/Q172DCPU system configuration, precautions on use of system, and configured equipments. 1.3.1 Motion system configuration

This section describes the equipment configuration, configuration with peripheral devices and system configuration in the Q173DCPU/Q172DCPU system.

(1) Equipment configuration in Q173DCPU/Q172DCPU system

Extension of the Q series module

Mitsubishi Electronics Q172DCPU — (1) Equipment configuration in Q173DCPU/Q172DCPU system diagram (page 25)
Fig. 3 · (1) Equipment configuration in Q173DCPU/Q172DCPU sys…

Q6 B extension base unit (Q63B, Q65B, Q68B, Q612B)

It is possible to select the best according to the system.

(Note-1) : Be sure to install the Battery (Q6BAT) to the Battery holder unit (Q170DBATC). It is packed together with Q173DCPU/Q172DCPU.

(Note-2) : Q172DEX cannot be used in the extension base unit. Mount it to the main base unit.

Page 26 of the Mitsubishi Electronics Q172DCPU user manual — (a) USB configuration
Page 26 · click to enlarge
Page 26

1 OVERVIEW

(2) Peripheral device configuration for the Q173DCPU/Q172DCPU

The following (a)(b) can be used.

(a) USB configuration

(b) RS-232 configuration

Mitsubishi Electronics Q172DCPU — (a) USB configuration diagram (page 26)
Fig. 4 · (a) USB configuration
Mitsubishi Electronics Q172DCPU — (a) USB configuration diagram (page 26)
Fig. 5 · (a) USB configuration
Page 27 of the Mitsubishi Electronics Q172DCPU user manual — 1 OVERVIEW
Page 27 · click to enlarge
Page 27

1 OVERVIEW

1.3.2 Q173DCPU System overall configuration

Motion CPU control module

Mitsubishi Electronics Q172DCPU — 1 OVERVIEW diagram (page 27)
Fig. 6

: Stop signal : Lower stroke limit : Upper stroke limit

MR-J3- B model Servo amplifier, Up to 32 axes (Up to 16 axes/system)

Page 28 of the Mitsubishi Electronics Q172DCPU user manual — 1 OVERVIEW
Page 28 · click to enlarge
Page 28

1 OVERVIEW

CAUTION

Construct a safety circuit externally of the Motion controller or servo amplifier if the abnormal

operation of the Motion controller or servo amplifier differ from the safety directive operation in the system. The ratings and characteristics of the parts (other than Motion controller, servo amplifier and

servomotor) used in a system must be compatible with the Motion controller, servo amplifier and servomotor. Set the parameter values to those that are compatible with the Motion controller, servo amplifier,

servomotor and regenerative resistor model and the system application. The protective functions may not function if the settings are incorrect.

Page 29 of the Mitsubishi Electronics Q172DCPU user manual — 1 OVERVIEW
Page 29 · click to enlarge
Page 29

1 OVERVIEW

1.3.3 Q172DCPU System overall configuration

Motion CPU control module

Mitsubishi Electronics Q172DCPU — 1 OVERVIEW diagram (page 29)
Fig. 7

(Up to 6 modules) (Q170ENC) E Serial absolute synchronous encoder 2/module

: Stop signal : Lower stroke limit : Upper stroke limit

Page 30 of the Mitsubishi Electronics Q172DCPU user manual — 1 OVERVIEW
Page 30 · click to enlarge
Page 30

1 OVERVIEW

CAUTION

Construct a safety circuit externally of the Motion controller or servo amplifier if the abnormal

operation of the Motion controller or servo amplifier differ from the safety directive operation in the system. The ratings and characteristics of the parts (other than Motion controller, servo amplifier and

servomotor) used in a system must be compatible with the Motion controller, servo amplifier and servomotor. Set the parameter values to those that are compatible with the Motion controller, servo amplifier,

servomotor and regenerative resistor model and the system application. The protective functions may not function if the settings are incorrect.

Page 31 of the Mitsubishi Electronics Q172DCPU user manual — R Vista/Windows
Page 31 · click to enlarge
Page 31

1 OVERVIEW

1.3.4 Software packages

(1) Software packages

(a) Operating system software

Mitsubishi Electronics Q172DCPU — 1 OVERVIEW diagram (page 31)
Fig. 8

(b) Motion controller programming software

Mitsubishi Electronics Q172DCPU — (b) Motion controller programming software diagram (page 31)
Fig. 9 · (b) Motion controller programming software
(Note)Operating environment to use MT Developer is Windows

R 2000

English version only.

(2) Operating environment of personal computer

Operating environment is shown below. IBM PC/AT with which Windows

R2000 English version operates normally.

R Vista/Windows

R XP/Windows

Mitsubishi Electronics Q172DCPU — R Vista/Windows diagram (page 31)
Fig. 10 · R Vista/Windows

R XP Home Edition (Service Pack 2 or later)

(Note-1)Microsoft, Windows and DirectX are either registered trademarks or trademarks of Microsoft

Corporation in the United States and/or other countries.

(Note-2) : Intel, Celeron and Pentium are trademarks of Intel Corporation in the U.S. and other countries.

Page 32 of the Mitsubishi Electronics Q172DCPU user manual — (b) Servo set up software package
Page 32 · click to enlarge
Page 32

1 OVERVIEW

(3) Operating system type/version

(a) Confirmation method in the operating system (CD)

Mitsubishi Electronics Q172DCPU — 1 OVERVIEW diagram (page 32)
Fig. 11
1. OS software type
2. OS software version

Example) When using Q173DCPU, SV22 and version 00A.

3. Serial number

1) SW8DNC-SV22QA 2) 00A (b) Confirmation method in MT Debeloper

The operating system(OS) type/version of connected CPU is displayed on the installation screen of MT Developer.

S V 2 2 Q A V E R 3 (OS software)

0 0 A

A or BQ173DCPU C or D : Q172DCPU
3. Motion SFC compatibility . : Motion SFC not compatibility

(4) Relevant software packages

(a) PLC software package

Model name Software package

(b) Servo set up software package

Model name Software package

Show 6 more labels / short text on this page
1) · 2) · 3) · OS version · GX Developer SW8D5C-GPPW-E · MR Configurator MRZJW3-SETUP221E
Page 33 of the Mitsubishi Electronics Q172DCPU user manual — R Vista/Windows
Page 33 · click to enlarge
Page 33

1 OVERVIEW

POINTS (1) When the operation of Windows is not unclear in the operation of this software,

refer to the manual of Windows or guide-book from the other supplier. (2) The following functions cannot be used when the computer is running under

R 2000. This product may not perform properly, when these functions are used.

Windows

R Vista, Windows

R XP or Windows

< Windows

  • R XP>
  • Activating the application with Windows R compatibility mode
  • Fast user switching
  • Remote desktop
  • Large size
  • x64 Edition (64 bit Windows R ) < Windows

R Vista/Windows

R 2000> • Large fonts

Page 34 of the Mitsubishi Electronics Q172DCPU user manual — 1 OVERVIEW
Page 34 · click to enlarge
Page 34

1 OVERVIEW

1.3.5 Restrictions on motion systems

(1) Combination of Multiple CPU system

(a) Motion CPU module cannot be used as standalone module.

Be sure to install the universal model PLC CPU module (Q03UDCPU/ Q04UDHCPU/Q06UDHCPU) to CPU No.1. For Universal model PLC CPU module, "Multiple CPU high speed taransmission function" must be set in the Multiple CPU settings.

(b) Only Multiple CPU high speed main base unit (Q38DB/Q312DB) can be

used.

(c) The combination of Q173DCPU/Q172DCPU and Q173HCPU(-T)/

Q172HCPU(-T)/Q173CPUN(-T)/Q172CPUN(-T) cannot be used.

(d) Up to four modules of PLC CPU modules (Q03UDCPU/Q04UDHCPU/

Q06UDHCPU/Motion CPU modules can be installed from the CPU slot (the slot on the right side of power supply module) to slot 2 of the main base unit. CPU modules called as CPU No.1 to CPU No.4 from the left sequentially. There is no restriction on the installation order of CPU No.2 to No.4. For CPU module except CPU No.1, an empty slot can be reserved for addition of CPU module. An empty slot can be set between CPU modules. However, the mounting condition when combining with the High performance PLC CPU module/Process CPU module/PC CPU module/C controller module is different depending on the specification of CPU modules, refer to the Manuals of each CPU modules.

(e) It takes about 10 seconds to startup (state that can be controlled) of Motion

CPU. Make a Multiple CPU synchronous startup setting suitable for the system.

(f) Execute the automatic refresh of the Motion CPU modules and PLC CPU

modules (Q03UDCPU/Q04UDHCPU/Q06UDHCPU) by using the automatic refresh of Multiple CPU high speed transmission area setting. When the High performance PLC CPU module/Process CPU module/PC CPU module/C controller module is mounted in the combination of Multiple CPU system, the Motion CPU module cannot be execute the automatic refresh with these modules.

(g) Use the Motion dedicated PLC instructions that starts by "D(P).". The Motion

dedicated PLC instructions that starts by "S(P)." cannot be used. When the High performance PLC CPU module/Process CPU module/PC CPU module/C controller module is mounted in the combination of Multiple CPU system, the Motion dedicated PLC instruction from these modules cannot be executed.

Page 35 of the Mitsubishi Electronics Q172DCPU user manual — 1 OVERVIEW
Page 35 · click to enlarge
Page 35

1 OVERVIEW

(2) Motion modules

(a) Installation position of Q172DEX(Note-1) is only the main base unit.

It cannot be used on the extension base unit.

(b) Q172DLX/Q173DPX can be installed on any of the main base unit/

extension base unit.

(c) Q172DLX/Q172DEX(Note-1)/Q173DPX cannot be installed in CPU slot and I/O

slot 0 to 2 of the main base unit. Wrong installation might damage the main base unit.

(d) Q172EX(-S1/-S2/-S3)/Q172LX/Q173PX(-S1) for Q173HCPU(-T)/

Q172HCPU(-T)/Q173CPUN(-T)/Q172CPUN(-T)/Q173CPU/Q172CPU cannot be used.

(e) Be sure to use the Motion CPU as the control CPU of Motion modules

(Q172DLX, Q172DEX(Note-1), Q173DPX, etc.) for Motion CPU. They will not operate correctly if PLC CPU is set and installed as the control CPU by mistake. Motion CPU is treated as a 32-point intelligent module by PLC CPU of other CPU. (Note-1) : Q172DEX can be used in SV22. It cannot be used in SV13.

Page 36 of the Mitsubishi Electronics Q172DCPU user manual — Q172DLX Q172LX Q172DLX
Page 36 · click to enlarge
Page 36

1 OVERVIEW

(3) Other restrictions

(a) Motion CPU module cannot be set as the control CPU of intelligent function

module (except some modules) or Graphic Operation Terminal(GOT).

(b) Be sure to use the external battery.

(c) There are following methods to execute the forced stop input.

  • Use a EMI terminal of Motion CPU module
  • Use a device set in the forced stop input setting of system setting

(d) Forced stop input for EMI terminal of Motion CPU module cannot be

invalidated by the parameter. When the device set in the forced stop input setting is used without use of EMI terminal of Motion CPU module, apply 24VDC voltage on EMI terminal and invalidate the forced stop input of EMI terminal.

(e) Be sure to use the cable for forced stop input (sold separately). The forced

stop cannot be released without using it.

(f) When the operation cycle is 0.4[ms], set the system setting as the axis select

switch of servo amplifier "0 to 7". If the axis select switch of servo amplifier "8 to F" is set, the servo amplifiers are not recognized.

(g) It is impossible to mount the main base unit by DIN rail when using the

Motion CPU module. Doing so could result in vibration that may cause erroneous operation.

(h) The module name displayed by "System monitor" - "Product information list"

of GX Developer is different depending on the function version of Motion modules (Q172DLX, Q172DEX, Q173DPX).

(Note)Even if the function version "C" is displayed, it does not correspond

to the online module change.

Model display Module name

Function version "B" Function version "C"

Q172DLX Q172LX Q172DLX

Q172DEX MOTION-UNIT Q172DEX

Q173DPX MOTION-UNIT Q173DPX

Page 37 of the Mitsubishi Electronics Q172DCPU user manual — 1 OVERVIEW
Page 37 · click to enlarge
Page 37

1 OVERVIEW

MEMO

Page 38 of the Mitsubishi Electronics Q172DCPU user manual — (3) Communication between CPUs in the Multiple CPU system
Page 38 · click to enlarge
Page 38

2 MULTIPLE CPU SYSTEM

2. MULTIPLE CPU SYSTEM

2.1 Multiple CPU System

2.1.1 Overview

(1) What is Multiple CPU system ?

A Multiple CPU system is a system in which more than one PLC CPU module and Motion CPU module (up to 4 modules) are mounted on several main base unit in order to control the I/O modules and intelligent function modules. Each Motion CPU controls the servo amplifiers connected by SSCNET cable.

(2) System configuration based on load distribution

(a) By distributing such tasks as servo control, machine control and information

control among multiple processors, the flexible system configuration can be realized.

(b) You can increase the number of control axes by using a multiple Motion

CPU modules. It is possible to control up to 96 axes by using the three CPU modules (Q173DCPU).

(c) By distributing the high-load processing performed on a single PLC CPU

over several CPU modules, it is possible to reduce the overall system PLC scan time.

(3) Communication between CPUs in the Multiple CPU system

(a) Since device data of other CPUs can be automatically read by the automatic

refresh function, the self CPU can also use them as those of self CPU.

(Note)When the High performance PLC CPU module/Process CPU

module/PC CPU module/C controller module is mounted in the combination of Multiple CPU system, the Motion dedicated PLC instruction from these modules cannot be executed.

(b) Motion dedicated PLC instructions can be used to access device data from

the PLC CPU to Motion CPU and start Motion SFC program.

Page 39 of the Mitsubishi Electronics Q172DCPU user manual — CPU 0 1 2
Page 39 · click to enlarge
Page 39

2 MULTIPLE CPU SYSTEM

2.1.2 Installation position of CPU module

Up to four PLC CPUs and Motion CPUs can be installed from the CPU slot (the right side slot of the power supply module) to slots 2 of the main base unit. The Motion CPU module cannot be installed in the CPU slot. The PLC CPU module must be installed in the CPU slot (CPU No.1) in the Multiple CPU system. There is no restriction on the installation order for CPU modules (CPU No.2 to 4). (Note): Refer to the manual for each CPU module when the High performance PLC

CPU module, Process CPU module, PC CPU module and C controller module is mounted in the combination of Multiple CPU.

Table 2.1 Example for CPU module installation

Mitsubishi Electronics Q172DCPU — Table 2.1 Example for CPU module installation diagram (page 39)
Fig. 12 · Table 2.1 Example for CPU module installation
CPU 0 1 2Slot number

An empty slot can be reserved for future addition of a CPU module. Set the number of CPU modules including empty slots in the Multiple CPU setting, and set the type of the slots to be emptied to "PLC (Empty)" in the CPU setting.

CPU 0 1 2

CPU 0 1 2

CPU 0 1 2

Q17 D

CPU Q17 D

Q17 D

CPU

CPU

CPU

CPU No.2 CPU No.1

CPU No.3

CPU No.4

CPU No.2 CPU No.1

CPU No.3

CPU No.4

CPU No.2 CPU No.1

CPU No.3

CPU No.4

Show 14 more labels / short text on this page
(Example 1) · (Example 2) · (Example 3) · Power supply · CPU QnUD(H) · CPU empty · Power supply · CPU QnUD(H) · CPU empty · CPU empty · Power supply · QnUD(H) · CPU empty · CPU empty
Page 40 of the Mitsubishi Electronics Q172DCPU user manual — REMARK
Page 40 · click to enlarge
Page 40

2 MULTIPLE CPU SYSTEM

2.1.3 Precautions for using I/O modules and intelligent function modules

(1) Modules controllable by the Motion CPU

  • Modules controllable by the Motion CPU are shown below.
  • Motion modules (Q172DLX, Q172DEX, Q173DPX)
  • I/O modules (QX , QY , QH , QX Y )
  • Analogue modules (Q6 AD , Q6 AD- , Q6 DA , Q6 DA- )
  • Interrupt module (QI60)

(2) Compatibility with the Multiple CPU system

The intelligent function modules of function version "B" or later support the Multiple CPU system. Be sure to use the PLC CPU as a control CPU because of the intelligent function modules cannot be controlled by the Motion CPU.

(3) Access range from non-controlled CPU

(a) The Motion CPU can access only the modules controlled by the self CPU. It

cannot access the modules controlled by other CPUs.

(b) Access range from non-controlled PLC CPU for the modules controlled by

the Motion CPU are shown below.

Table 2.2 Access range to non-controlled module

Mitsubishi Electronics Q172DCPU — Table 2.2 Access range to non-controlled module diagram (page 40)
Fig. 13 · Table 2.2 Access range to non-controlled module

: Accessible : Inaccessible

REMARK

  • The function version of an intelligent function module can be checked on the rated plate of the intelligent function module or in the GX Developer's system monitor product information list.
  • Refer to the "Q173DCPU/Q172DCPU User's Manual" for the model name which can be controlled by the Motion CPU.
Page 41 of the Mitsubishi Electronics Q172DCPU user manual — 2 MULTIPLE CPU SYSTEM
Page 41 · click to enlarge
Page 41

2 MULTIPLE CPU SYSTEM

2.1.4 Modules subject to installation restrictions

(1) Modules subject to install restrictions for the Motion CPU are sown below. Use

within the restrictions listed below.

Mitsubishi Electronics Q172DCPU — 2 MULTIPLE CPU SYSTEM diagram (page 41)
Fig. 14

(Note-1) : When the Manual pulse generator and the serial encoder are used at the same time with the SV22, the

Q173DPX installed in the slot of the smallest number is used for manual pulse generator input.

(Note-2) : SV22 only.

(2) A total of eight base units including one main base unit and seven extension base

units can be used. However, the usable slots (number of modules) are limited to 64 per system including empty slots. If a module is installed in slot 65 or subsequent slot, an error (SP. UNIT LAY ERROR) will occur. Make sure all modules are installed in slots 1 to 64. (Even when the total number of slots provided by the main base unit and extension base units exceeds 65 (such as when six 12-slot base units are used), an error does not occur as long as the modules are installed within slots 1 to 64.)

Mitsubishi Electronics Q172DCPU — 2 MULTIPLE CPU SYSTEM diagram (page 41)
Fig. 15

POINT (1) Q172DLX/Q172DEX/Q173DPX cannot be installed in CPU slot and I/O slot 0

to 2 of the main base unit. Wrong installation might damage the main base unit. (2) Q172DEX can be installed in the main base unit only. It cannot be used in the

Page 42 of the Mitsubishi Electronics Q172DCPU user manual — 2 MULTIPLE CPU SYSTEM
Page 42 · click to enlarge
Page 42

2 MULTIPLE CPU SYSTEM

2.1.5 How to reset the Multiple CPU system

The entire Multiple CPU system can be reset by resetting CPU No.1. The CPU modules of No.2 to No.4, I/O modules and intelligent function modules will be reset when PLC CPU No.1 is reset. If a stop error occurs in any of the CPUs on the Multiple CPU system, either reset CPU No.1 or restart the Multiple CPU system (power supply ON OFF ON) for recovery. (Recovery is not allowed by resetting the error-stopped CPU modules other than CPU No.1.)

POINT (1) It is not possible to reset the CPU modules of No.2 to No.4 individually in the

Multiple CPU system. If an attempt to reset any of those PLC CPU modules during operation of the Multiple CPU system, a "MULTI CPU DOWN (error code: 7000)" error will occur for the other CPUs, and the entire Multiple CPU system will be halted. However, depending on the timing in which any of PLC CPU modules other than No.1 has been reset, an error other than the "MULTI CPU DOWN" may halt the other PLC CPUs/Motion CPUs. (2) A "MULTI CPU DOWN (error code: 7000)" error will occur regardless of the

operation mode(All stop by stop error of CPU "n"/continue) set at the "Multiple CPU setting" screen when any of PLC CPU modules of No.2 to No.4 is reset. (Refer to Section 2.1.6.)

Page 43 of the Mitsubishi Electronics Q172DCPU user manual — A
Page 43 · click to enlarge
Page 43

2 MULTIPLE CPU SYSTEM

2.1.6 Operation for CPU module stop error

The entire system will behaves differently depending whether a stop error occurs in CPU No.1 or any of CPU No.2 to No.4 in the Multiple CPU system.

(1) When a stop error occurs at CPU No.1

(a) A "MULTI CPU DOWN (error code: 7000)" error occurs at the other CPUs

and the Multiple CPU system will be halted when a stop error occurs at the PLC CPU No.1. (Note-1)

(b) The following procedure to restore the system is shown below.

1. Confirm the error cause with the PLC diagnostics on GX Developer.
2. Remove the error cause.
3. Either reset the PLC CPU No.1 or restart the power to the Multiple CPU system (power ON OFF ON).

All CPUs on the entire Multiple CPU system will be reset and the system will be restored when PLC CPU No. 1 is reset or the Multiple CPU system is reapplied.

(2) When a stop error occurs at CPU other than No.1

Whether the entire system is halted or not is determined by the Multiple CPU setting's "Operating Mode" setting when a stop error occurs in a PLC CPU module/Motion CPU module other than CPU No.1. The default is set for all CPUs to be stopped with a stop error. When you do not want to stop all CPUs at occurrence of a stop error in a PLC CPU module/Motion CPU module, remove the check mark that corresponds to the CPU No. so that its error will not stop all CPUs. (See arrow A.)

Mitsubishi Electronics Q172DCPU — (2) When a stop error occurs at CPU other than No.1 diagram (page 43)
Fig. 16 · (2) When a stop error occurs at CPU other than No.1

A

(a) When a stop error occurs in the CPU module for which "All station stop by

stop error of CPU 'n' " has been set, a "MULTI CPU DOWN (error code: 7000)" error occurs for the other PLC CPU module/Motion CPU modules and the Multiple CPU system will be halted. (Note-1)

Page 44 of the Mitsubishi Electronics Q172DCPU user manual — 2 MULTIPLE CPU SYSTEM
Page 44 · click to enlarge
Page 44

2 MULTIPLE CPU SYSTEM

(b) When a stop error occurs in the CPU module for which " All station stop by

stop error of CPU 'n' " has not been set, a "MULTI EXE. ERROR (error code: 7010)" error occurs in all other CPUs but operations will continue. POINT (Note-1) : When a stop error occurs, a "MULTI CPU DOWN (error code : 7000)"

stop error will occur at the CPU on which the error was detected. Depending on the timing of error detection, a "MULTI CPU DOWN" error may be detected in a CPU of "MULTI CPU DOWN" status, not the first CPU on which a stop error occurs. Because of this, CPU No. different from the one of initial error CPU may be stored in the error data's common information category. To restore the system, remove the error cause on the CPU that is stopped by an error other than "MULTI CPU DOWN". In the screen below, the cause of the CPU No.2 error that did not cause the "MULTI CPU DOWN" error is to be removed.

Mitsubishi Electronics Q172DCPU — 2 MULTIPLE CPU SYSTEM diagram (page 44)
Fig. 17

(c) Observe the following procedures to restore the system.

1. Confirm the error-detected CPU No. and error cause with the PLC diagnostics on GX Developer. 2) If the error code occurred in Motion CPU 10000 to 10999, confirm the error cause with Motion CPU error batch monitor of MT Developer. 3) Remove the error cause. 4) Either reset the PLC CPU No.1 or restart the power to the Multiple CPU system (power ON OFF ON).

All CPUs on the entire Multiple CPU system will be reset and the system will be restored when PLC CPU No.1 is reset or the power to the Multiple CPU system is reapplied.

Page 45 of the Mitsubishi Electronics Q172DCPU user manual — 2 MULTIPLE CPU SYSTEM
Page 45 · click to enlarge
Page 45

2 MULTIPLE CPU SYSTEM

(3) Operation at a Motion CPU error

Operations at a Motion CPU error are shown below.

Category Type of error Operation Remark

System setting error Does not operate from the

  • All actual output PY points turn OFF.

beginning (does not run).

No effect on other CPUs.

WDT error Varies depending on the error.

  • All actual output PY points turn OFF.

Other CPUs may also stop depending on

the parameter setting. Operation

Self-diagnosis error Stops at a CPU DOWN error.

STOP (M2000 OFF). Depends on

Other CPU DOWN error

  • All actual output PY points turn OFF.

the "Operation mode upon CPU

stop error" setting.

Self-diagnosis error Operation continues when the

continuous error occurred.

  • Only the applicable program stops (the

Processing stops for each

program may continue depending on the

program or axis instead of the

type of error).

Motion CPU stopping all the

  • Actual output PY retains output.

processing.

  • No effect on other CPUs.
Show 11 more labels / short text on this page
disable errors · Operation corresponding to · Motion SFC error · Operation · Minor error · continuous · Major error · enable errors · Servo error · Servo program setting · error
Page 46 of the Mitsubishi Electronics Q172DCPU user manual — PLC CPU
Page 46 · click to enlarge
Page 46

2 MULTIPLE CPU SYSTEM

2.2 Starting Up the Multiple CPU System

This section describes a standard procedure to start up the Multiple CPU system. 2.2.1 Startup Flow of the Multiple CPU System

START

Definition of functions with Multiple CPU system

Control and function executed in each CPU module are defined.

Application and assignment of device

Refer to Section 2.3

When automatic refresh of the CPU shared memory is performed, the number of refresh points is continuously obtained.

Refer to the "Q173DCPU/Q172DCPU User's Manual"

Select the module to achieve the function with the Multiple CPU system.

PLC CPU Motion CPU

Refer to the "Q173DCPU/Q172DCPU User's Manual"

Install the selected module on the main base unit and extension base unit.

Start-up of GX Developer

Refer to the GX Developer Manual.

Start-up GX Developer (Ver. 8.48A or later).

Creation of parameters, etc.

Create the parameters for CPU No. 1 to 4 and PLC programs.

Create the parameter such as Multiple CPU setting and control CPU setting, and the PLC program.

Refer to the "QCPU User's Manual" (Function Explanation/Program Fundamentals)".

Connection of PC to the PLC CPU module of CPU No. 1

PLC CPU

Connect the PC that started GX Developer to the PLC CPU module of CPU No. 1 with the RS-232 cable/ USB cable.

Multiple CPU system power ON

Turn ON the power of Multiple CPU system in the following state of PLC CPU module of CPU No.1. RUN/STOP/RESET switch : STOP

Write of parameter and program

Write parameter and PLC program in the PLC CPU of CPU No. 1. For PLC CPU other than CPU No. 1, select the applicable PLC CPU by specifying the connection.

PLC CPU

Selection of module · Installation of module · 1)

Page 47 of the Mitsubishi Electronics Q172DCPU user manual — END
Page 47 · click to enlarge
Page 47

2 MULTIPLE CPU SYSTEM

Start-up of MT Developer Refer to the help for operation of MT Developer.

Start-up MT Developer.

Creation of system settings and

Refer to Section 3.1 for system settings.

program, etc.

Refer to the Programming Manual of each operating system software for details of program.

Create the system settings, servo data and Motion SFC program.

Write to the Motion CPU

Write the system settings, servo data and Motion SFC program.

Switch setting for all CPUs

PLC CPU Motion CPU

Set RUN/STOP/RESET switch of PLC CPU modules and RUN/STOP switch of Motion CPU modules in CPU No.1 to 4 to RUN.

Reset PLC CPU module of CPU No.1

Set RUN/STOP/RESET switch of PLC CPU module in CPU No.1 to RESET to reset the entire system.

PLC CPU

Status check in all CPU modules

Check if all CPUs of the Multiple CPU system are RUN status/error by resetting the CPU module of CPU No. 1.

Check and correction of errors

An error is checked with the PC diagnosis function of GX Developer and Motion CPU error batch monitor of MT Developer for correction.

PLC CPU Motion CPU

Debug of each CPU module

Multiple CPU system is debugged for each PLC CPU/Motion CPU.

Check in the automatic operation.

END

(Note) : Installation of the operating system software is required to the Motion CPU module before start of

the Multiple CPU system. Refer to Chapter 5 of the "Q173DCPU/Q172DCPU User's Manual" for installation of the Motion CPU operating system software.

1) · Motion CPU · Actual operation

Page 48 of the Mitsubishi Electronics Q172DCPU user manual — REMARK
Page 48 · click to enlarge
Page 48

2 MULTIPLE CPU SYSTEM

2.3 Communication between the PLC CPU and the Motion CPU in the Multiple CPU System

2.3.1 CPU shared Memory

(1) Structure of CPU shared memory

  • The CPU shared memory is memory provided for each CPU module by which data is written or read between CPU modules of a Multiple CPU system. The CPU shared memory consists of four areas.
  • Self CPU operation information area
  • System area
  • User setting area
  • Multiple CPU high speed transmission area

The CPU shared memory configuration and the availability of the communication from the self CPU using the CPU shared memory by program are shown below.

Mitsubishi Electronics Q172DCPU — 2.3.1 CPU shared Memory diagram (page 48)
Fig. 18 · 2.3.1 CPU shared Memory

(0H)

(1FFH)

(200H)

(7FFH)

(800H)

(FFFH) (1000H)

(270FH) (2710H)

Multiple CPU high speed transmission area (Variable size in 0 to 14k[points]: 1k words in unit)

(5F0FH)

: Communication allowed : Communication not allowed

REMARK

(Note-1)Use the MULTW instruction to write to the user setting area of the self

CPU in the Motion CPU. Use the S. TO instruction to write to the user setting area of the self CPU in the PLC CPU. (Note-2) : Use the MULTR instruction to read the shared memory of self CPU and

other CPU in the Motion CPU. Use the FROM instruction/Multiple CPU area device (U \G ) to read the shared memory of the Motion CPU from the PLC CPU. (Note-3) : Refer to Section 2.3.2(1) for the access method of Multiple CPU high

speed transmission area.

Show 13 more labels / short text on this page
to · to · to · to · to · to · 4095 4096 · to · to · 9999 10000 · to · to · up to 24335
Page 49 of the Mitsubishi Electronics Q172DCPU user manual — SD4
Page 49 · click to enlarge
Page 49

2 MULTIPLE CPU SYSTEM

(a) Self CPU operation information area (0H to 1FFH)

1. The following information of self CPU is stored as the Multiple CPU system

Table 2.3 Table of self CPU operation information areas

Name Detail Description (Note) Corresponding special register

  • The area to confirm if information is stored in the self CPU's operation information area (1H to 1FH) or not.
  • 0: Information not stored in the self CPU's operation information area.
  • 1: Information stored in the self CPU's operation information area.

0H Information availability Information availability flag

1H Diagnostic error Diagnostic error number An error No. identified during diagnosis is stored in BIN. SD0

2H The year and month that the error number was stored in the CPU shared memory's 1H address is stored with two digits of the BCD code.

SD1

3H The date and time that the error number was stored in the CPU shared memory's 1H address is stored with two digits of the BCD code.

Time the diagnostic error occurred

Time the diagnostic error occurred

SD2

The minutes and seconds that the error number was stored in the CPU shared memory's 1H address is stored with two digits of the BCD code.

4H

SD3

Stores an identification code to determine what error information has been stored in the common error information and individual error information.

5H Error information identification code

Error information identification code

SD4

6H to 10H Common error information Common error information The common information corresponding to the error number identified during diagnosis is stored. SD5 to SD15

11H to 1BH Individual error information

The individual information corresponding to the error number identified during diagnostic is stored. SD16 to SD26

1CH Empty — Cannot be used —

1DH Switch status CPU switch status Stores the CPU module switch status. SD200

1EH Empty — Cannot be used —

1FH CPU operation status CPU operation status Stores the CPU module's operation status. SD203

(Note) : Refer to the corresponding special register for details.

2. The self CPU operation information area is refreshed every time the applicable register has been changed in the main cycle. 3) Other PLC CPU can use FROM instruction to read data from the self CPU operation information area. However, because there is a delay in data updating, use the read data for monitoring purposes only.

The area used by the operating systems (OS) of the PLC CPU/Motion CPU.

(c) User setting area

The area for communication between CPU modules in the Multiple CPU system by MULTR/MULTW instruction of Motion CPU. (PLC CPU use FROM/S.TO instruction or Multiple CPU area devices to communicate between CPU modules.) Refer to the Programming Manual of operating system software for MULTR/MULTW instruction.

Show 4 more labels / short text on this page
CPU shared · memory address · Individual error information · (b) System area
Page 50 of the Mitsubishi Electronics Q172DCPU user manual — U3E1\G10000
Page 50 · click to enlarge
Page 50

2 MULTIPLE CPU SYSTEM

(d) Multiple CPU high speed transmission area

The area corresponding to the Multiple CPU high speed main base unit (Q3 DB) and Multiple CPU high speed transmission that uses the drive system controllers including QnUD(H)CPU and Motion CPU. The image chart of Multiple CPU high speed transmission area is shown below. Refer to Section 2.3.2(1) for access to the Multiple CPU high speed transmission area of self CPU and other CPU.

CPU No.1

CPU No.2

CPU No.3 CPU No.4

U3E0\G10000

CPU No.1 Multiple CPU high speed transmission area (Transmission)

CPU No.1 Multiple CPU high speed transmission area (Reception)

CPU No.1 Multiple CPU high speed transmission area (Reception)

CPU No.1 Multiple CPU high speed transmission area (Reception)

CPU No.2 Multiple CPU high speed transmission area (Reception)

CPU No.2 Multiple CPU high speed transmission area (Transmission)

CPU No.2 Multiple CPU high speed transmission area (Reception)

CPU No.2 Multiple CPU high speed transmission area (Reception)

U3E1\G10000

U3E2\G10000

CPU No.3 Multiple CPU high speed transmission area (Reception)

CPU No.3 Multiple CPU high speed transmission area (Reception)

CPU No.3 Multiple CPU high speed transmission area (Transmission)

CPU No.3 Multiple CPU high speed transmission area (Reception)

U3E3\G10000 CPU No.4 Multiple CPU high speed transmission area (Reception)

CPU No.4 Multiple CPU high speed transmission area (Reception)

CPU No.4 Multiple CPU high speed transmission area (Reception)

CPU No.4 Multiple CPU high speed transmission area (Transmission)

(Note-1) : The final device is "10000+(A 1024-B-1)". A : Data transmission size of each CPU (1k words in unit) B : Size used in the automatic refresh of each CPU. Refer to Section "2.3.2 Multiple CPU high speed transmission" for the size setting of A and B. (Note-2) : Transmission area to write/read in the self CPU. Reception area from the other CPU can be read only.

It is updated every 0.88ms.

Show 12 more labels / short text on this page
(Note-2) · to · (Note-1) U3E0\G · (Note-2) · to · (Note-1) U3E1\G · (Note-2) · to · (Note-1) U3E2\G · (Note-2) · to · (Note-1) U3E3\G
Page 51 of the Mitsubishi Electronics Q172DCPU user manual — 2 MULTIPLE CPU SYSTEM
Page 51 · click to enlarge
Page 51

2 MULTIPLE CPU SYSTEM

2.3.2 Multiple CPU high speed transmission

(1) Multiple CPU high speed transmission

Multiple CPU high speed transmission is a function for fixed cycle data transmission between Multiple CPUs (Multiple CPU high speed transmission cycle is 0.88ms.). Secure data transmission is possible without effecting the PLC CPU scan time or Motion CPU main cycle because the data transmission and execution of PLC program and Motion SFC program can be executed with parallel processing. High speed response between multiple CPUs is realized by synchronizing the Multiple CPU high speed transmission cycle with Motion CPU operation cycle.

  • The following methods of data transmission exist between Multiple CPUs for Multiple CPU high speed transmission.
  • Multiple CPU area device method Directly set the Multiple CPU high speed transmission area by Multiple CPU area device (U \G ) in the program.
  • Automatic refresh method Refresh the internal devices of each CPU by automatic refresh via "Multiple CPU high speed transmission area".

(a) Multiple CPU area device method

Mitsubishi Electronics Q172DCPU — 2 MULTIPLE CPU SYSTEM diagram (page 51)
Fig. 19

CPU shared memory (User setting area (Note-1)) PLC program Motion SFC program

1), 4) : Write data in the user setting area (Note-1) by the instruction that uses the Multiple CPU area device. 3), 6) : Read data from the user setting area (Note-1) by the instruction that uses the Multiple CPU area device. 2), 5) : Transmit the contents of user setting area (Note-1) to the other CPU with by Multiple CPU high speed transmission in 0.88ms cycle. Note-1: The area composed in the Multiple CPU high speed transmission area. (Refer to Section "(3) Memory configuration of Multiple CPU high speed transmission area".)

Page 52 of the Mitsubishi Electronics Q172DCPU user manual — : U \ G
Page 52 · click to enlarge
Page 52

2 MULTIPLE CPU SYSTEM

1. Access to Multiple CPU high speed transmission area a) Description of Multiple CPU area device

: U \ G

CPU shared memory address (decimal) (10000 to up to 24335)

First I/O number of CPU module

CPU No. First I/O number 3E0(H) CPU No.1

3E1(H) CPU No.2

3E2(H) CPU No.3

3E3(H) CPU No.4

: U \ G . Bit device

Bit specification (0 to FHexadecimal)

CPU shared memory address (decimal) (10000 to up to 24335)

First I/O number CPU module

CPU No. First I/O number 3E0(H) CPU No.1

3E1(H) CPU No.2

3E2(H) CPU No.3

3E3(H) CPU No.4

  • (Example)
  • Multiple CPU high speed transmission memory address of CPU No. 2: 10002 U3E1\G10002
  • Bit 14 of CPU No. 3 Multiple CPU high speed transmission memory address 10200 U3E2\G10200.E b) Example of access in the program
  • <Motion SFC program>
  • Store K12345678 to the Multiple CPU high speed transmission memory 10200,10201 of self CPU (CPU No.2). U3E1\G10200L = K12345678
  • Turn on bit 12 of the Multiple CPU high speed transmission memory 10301 of self CPU (CPU No.3) SET U3E2\G10301.C

• Program which executes the positioning for Axis 1 to position set in the Multiple CPU high speed transmission memory 10400, 10401 of CPU No.1 at the speed set in the 10402, 10403 of CPU No.1, and uses bit 1 of CPU No.1 Multiple CPU high speed transmission memory 10404 of CPU No.1 as a cancel signal.

ABS-1 Axis 1, U3E0\G10400 Speed U3E0\G10402 Cancel U3E0\G10404.1

POINT This method can be used to access only the Multiple CPU high speed transmission area of CPU shared memory. It cannot be used to access the CPU shared memory (0 to 4095).

Word device

Page 53 of the Mitsubishi Electronics Q172DCPU user manual — transmission
Page 53 · click to enlarge
Page 53

2 MULTIPLE CPU SYSTEM

(b) Example of using automatic refresh method

Mitsubishi Electronics Q172DCPU — 2 MULTIPLE CPU SYSTEM diagram (page 53)
Fig. 20

Refresh at the timing of Motion CPU main cycle

1) Transmit the content of D0 to the automatic refresh area (Note-1) at the time of END processing by parameter setting. 2) Transmit the content of automatic refresh area (Note-1) to the other CPU by Multiple CPU high speed transmission at 0.88ms cycle. 3) Read the content of automatic refresh area (Note-1) at the time of Motion CPU main cycle and transmit it to D2000 by parameter setting. . Note-1: The area composed in the Multiple CPU high speed transmission area. (Refer to Section "(3) Memory configuration of Multiple CPU high speed transmission area".)

(2) System configuration

Multiple CPU high speed transmission can be used only between CPU modules for the Multiple CPU high speed transmission installed in the Multiple CPU high speed main base unit (Q3 DB). The system configuration specification is shown in Table 2.4. Table 2.4 System configuration to use Multiple CPU high speed

transmission

Mitsubishi Electronics Q172DCPU — transmission diagram (page 53)
Fig. 21 · transmission

Base unit Multiple CPU high speed main base unit (Q3 DB) is used.

CPU module Q173DCPU/Q172DCPU and QnUD(H)CPU are used for CPU No. 2 to

"MULTI EXE. ERROR (error code: 7011) will occur if the power supply of Multiple CPU system is turned on without matching the system configuration shown in Table 2.4.

Page 54 of the Mitsubishi Electronics Q172DCPU user manual — Table 2.5 Description of area
Page 54 · click to enlarge
Page 54

2 MULTIPLE CPU SYSTEM

(3) Memory configuration of Multiple CPU high speed transmission

area Memory configuration of Multiple CPU high speed transmission area is shown below.

Mitsubishi Electronics Q172DCPU — 2 MULTIPLE CPU SYSTEM diagram (page 54)
Fig. 22

User setting area Multiple CPU high speed transmission area [Variable in 0 to 14k[points] (Note-1)] Automatic refresh area 7)

(Note-1): Multiple CPU high speed transmission area; 14k[points]: Maximum value when constituted with two CPUs 13k[points]: Maximum value when constituted with three CPUs 12k[points]: Maximum value when constituted with four CPUs

Table 2.5 Description of area

Mitsubishi Electronics Q172DCPU — Table 2.5 Description of area diagram (page 54)
Fig. 23 · Table 2.5 Description of area
  • Area for data transmission between each CPU module
  • The area up to 14k [points] is divided between each
  • Area to store the send data of the each CPU module.
  • Sends the data stored in the send area of self CPU to
  • Other CPU send area stores the data received from
  • Area for data communication with other CPUs using
  • Can be accessed by the user program using the
  • Refer to Section 2.3.2 (1) for details of this area.
  • Area for communicating device data with other CPUs
  • Refer to Section "(4)(b) Automatic refresh setting" for
Page 55 of the Mitsubishi Electronics Q172DCPU user manual — 2 MULTIPLE CPU SYSTEM
Page 55 · click to enlarge
Page 55

2 MULTIPLE CPU SYSTEM

(4) Parameter setting

The parameter setting list for use with the Multiple CPU high speed transmission is shown in Table 2.6. Table 2.6 Multiple CPU high speed transmission parameter list

Name Description Target CPU

Set the size of the Multiple CPU high speed

transmission area allocated in each CPU module

which composes the Multiple CPU system.

Set the range to execute the data transmission by

the automatic refresh function among the user area

in the Multiple CPU high speed transmission area.

(a) Multiple CPU high speed transmission area setting

Multiple CPU high speed transmission area setting screen and setting range are shown below.

Show 6 more labels / short text on this page
Multiple CPU high · speed transmission · area setting · All CPUs · Automatic refresh · setting
Page 56 of the Mitsubishi Electronics Q172DCPU user manual — 2 MULTIPLE CPU SYSTEM
Page 56 · click to enlarge
Page 56

2 MULTIPLE CPU SYSTEM

Table 2.7 Parameter setting items of Multiple CPU high speed transmission area setting

Item Setting description Setting/display value Restriction Consistency

CPU CPU No. corresponding to displayed parameters. CPU No.1 to No.4 — —

Set the number of points of data that each CPU module sends. Default value assigned to each CPU is shown below.

  • Set the total of all CPUs to be the following points or lower. When constituted with two CPUs: 14k [points] When constituted with three CPUs: 13k [points] When constituted with four CPUs: 12k [points]

Default value of CPU specific

Range0 to 14k [points] Unit: 1k [point] (Points: Word in units)

CPU specific send range

CPUs CPU No.1

CPU No.2

CPU No.3

CPU No.4

2 7k 7k — —

3 7k 3k 3k —

4 3k

Number of points used in the automatic refresh function is displayed. Number of points that is set by the "automatic refresh setting" is displayed.

Range0 to 14336 [points] Unit: 2 [points]

Do not exceed the CPU specific send range [points]. —

Area size specified directly by program is displayed. The value where the "number of points set in the automatic refresh" is subtracted from the "CPU specific send range setting" is displayed.

Range0 to 14336 [points] Unit: 2 [points] — —
Show 6 more labels / short text on this page
check · Number of · send range [points] · Provided · Automatic refresh · User setting area
Page 57 of the Mitsubishi Electronics Q172DCPU user manual — 2 MULTIPLE CPU SYSTEM
Page 57 · click to enlarge
Page 57

2 MULTIPLE CPU SYSTEM

POINT Selecting "Advanced setting" enables the ability to change the number of points from 1k to 2k in the system area used for Motion dedicated PLC instructions. Changing the number of points in the system area to 2k increases the number of Motion dedicated PLC instructions that can be executed concurrently in a scan. The screen where "Advanced setting" is selected is shown below. Refer to the "Q173DCPU/Q172DCPU Motion controller (SV13/SV22) Programming Manual (Motion SFC) " for the Motion dedicated PLC instruction.

Mitsubishi Electronics Q172DCPU — 2 MULTIPLE CPU SYSTEM diagram (page 57)
Fig. 24

Item Setting description Setting/display value (Points: Word in units) Restriction

  • Set the total of all CPUs to

be the following points or

lower.

When constituted with two

CPU specific send range

Set the number of points of data that each CPU module sends.

Range0 to 14k [points] Unit: 1k [points]
CPUs14k [points]
three CPUs13k [points]

When constituted with four

CPUs12k [points]

Set the number of points for a system area to be assigned for each CPU module. (Default value of system area size is 1k [point].)

Range1k/2k [points] — Provided

Display the total of number of points of the self CPU send area and the system area that are assigned to the each CPU module.

Range1 to 16k [points] Unit: 1k [points]

Set the total of all CPUs to 16.0k points or lower. —

Show 6 more labels / short text on this page
Data size consistency · check · Provided · When constituted with · System area · Total
Page 58 of the Mitsubishi Electronics Q172DCPU user manual — Table 2.8 Parameter setting items of automatic refresh setting
Page 58 · click to enlarge
Page 58

2 MULTIPLE CPU SYSTEM

(b) Automatic refresh setting

Setting for use of the automatic refresh function in the Multiple CPU high speed transmission area. Up to 32 setting ranges can be set for each CPU module. Automatic refresh setting screen and setting range are shown below.

Mitsubishi Electronics Q172DCPU — 2 MULTIPLE CPU SYSTEM diagram (page 58)
Fig. 25

Table 2.8 Parameter setting items of automatic refresh setting

Item Setting description Setting range Restriction

  • CPU No. which exceeds the number of CPU modules cannot be selected.

Select the CPU module for editing of the CPU specific send range setting. CPU No.1 to No.4

The setting No. for transmission of each CPU module is displayed. Automatic refresh is executed between devices set to the same setting No. for all CPUs that constitute the Multiple CPU system.

Setting No.

1 to 32 — —

  • Setting which exceeds the number of points of the self CPU send area allocated to the each CPU module (CPU specific send range) cannot be set.
  • Bit device can be specified in units of 32 points (2 words) only.

Points Set the number of points for data communication.

Range2 to 14336 [points] Unit: 2 [points]

Specifies the device which performs the data communication (automatic refresh). Specifies the device sent by the self CPU when the "Send source CPU selection" is the self CPU, and specifies the device received by the self CPU when the CPU specific send range setting is the other CPU.

Usable device ( X, Y, M, B, D, W, #, SM, SD) Note) Set "blank" when

  • Bit device can be specified in units of 16 points (1 word) only.
  • Device number cannot be duplicated.

automatic refresh is not executed.

Show 6 more labels / short text on this page
Data size consistency · check · CPU selection · Provided · Start · None
Page 59 of the Mitsubishi Electronics Q172DCPU user manual — 2 MULTIPLE CPU SYSTEM
Page 59 · click to enlarge
Page 59

2 MULTIPLE CPU SYSTEM

POINT The processing performance of automatic refresh improves when devices are transmitted in 2 word sets. Therefore, it is recommended to set the start device as 2 word unit by inputting an even device number.

1. Operation example of automatic refresh a) Parameter setting

The example of setting automatic refresh is shown below.

  • CPU No.1 (PLC CPU) (GX Developer) Set the device transmitted to CPU No.2.
  • CPU No.2 (Motion CPU) (MT Developer) Set the device received from CPU No.1.
Mitsubishi Electronics Q172DCPU — 2 MULTIPLE CPU SYSTEM diagram (page 59)
Fig. 26
Mitsubishi Electronics Q172DCPU — 2 MULTIPLE CPU SYSTEM diagram (page 59)
Fig. 27

Set the device received from CPU No.2.

Set the device transmitted to CPU No.1.

Mitsubishi Electronics Q172DCPU — 2 MULTIPLE CPU SYSTEM diagram (page 59)
Fig. 28
Mitsubishi Electronics Q172DCPU — 2 MULTIPLE CPU SYSTEM diagram (page 59)
Fig. 29

(Note) : The operation example of automatic refresh is shown on the next page.

Page 60 of the Mitsubishi Electronics Q172DCPU user manual — 2 MULTIPLE CPU SYSTEM
Page 60 · click to enlarge
Page 60

2 MULTIPLE CPU SYSTEM

Mitsubishi Electronics Q172DCPU — 2 MULTIPLE CPU SYSTEM diagram (page 60)
Fig. 30

POINT Set the following operation for automatic refresh setting using GX Developer. 1) Select tab "Multiple CPU high speed communication area setting". 2) Set "Use Multiple CPU high speed communication ".

The example of operating automatic refresh is shown below.

PLC CPU (CPU No.1) Motion CPU (CPU No.2)

Mitsubishi Electronics Q172DCPU — 2 MULTIPLE CPU SYSTEM diagram (page 60)
Fig. 31

(c) Data size consistency check

Whether the Multiple CPU setting parameters are the same for all CPUs or not is automatically checked. A "PARAMETER ERROR (error code: 3012, 3015) " will occur if they do not match.

b) Operation example

Page 61 of the Mitsubishi Electronics Q172DCPU user manual — 2 MULTIPLE CPU SYSTEM
Page 61 · click to enlarge
Page 61

2 MULTIPLE CPU SYSTEM

(5) Precautions

(a) Assurance of data sent between CPUs

Due to the timing of data sent from the self CPU and automatic refresh in any of the other CPUs, old data and new data may become mixed (data separation). The following shows the methods for avoiding data separation at communications by automatic refresh. 1) Data consistency for 32 bit data Transfer data with automatic refresh method is in units of 32 bits. Since automatic refresh is set in units of 32 bits, 32-bit data does not separate. • For word data 2 words data can be prevented from separating by using an even number to set the first number of each device in automatic refresh setting. 2) Data consistency for data exceeding 32 bits In automatic refresh method, data is read in descending order of the setting number in automatic refresh setting parameter. Transfer data separation can be avoided by using a transfer number lower than the transfer data as an interlock device.

Page 62 of the Mitsubishi Electronics Q172DCPU user manual — (1) Application example of Multiple CPU high speed refresh function
Page 62 · click to enlarge
Page 62

2 MULTIPLE CPU SYSTEM

2.3.3 Multiple CPU high speed refresh function

This function is used to update the data between internal devices of Motion CPU and the Multiple CPU high speed transmission area. This occurs every operation cycle as defined in the device setting of automatic refresh in the self CPU.

Classification Item Description Setting/display value Restriction

Setting No. Setting No. which executes high speed refresh is displayed.

1 to 128 (Up to 128)

CPU No. set in the automatic refresh setting is automatically displayed by setting devices. Self CPU : Refresh from the internal device

of Motion CPU to Multiple CPU high speed transmission area. Other CPU : Refresh form the Multiple CPU

CPU

CPU No. 1 to No.4

high speed transmission area to internal device of Motion CPU.

  • The start device number must be a multiple of 16 for the bit device.
  • Do not set a device not setting also set in the automatic refresh.
  • No. of "start device + number of points" cannot exceed setting range of each setting No. in automatic refresh setting.
  • Do not overlap the device No. between setting No..

Set the device No. of Motion CPU to execute the high speed refreshes.

Usable deviceD, W, #, SD, M, X, Y, B, SM

Set the number of points to refresh data of each data in word unit. (Note) Refresh is not executed when not set.

Range2 to 256 [points] Unit: 2 points (Note-1)
  • Sets the total of all CPUs to 256 points or lower.

Refresh cycle Operation cycle (fixed) — —

(Note-1) : Point in word unit.

Mitsubishi Electronics Q172DCPU — CPU diagram (page 62)
Fig. 32

(1) Application example of Multiple CPU high speed refresh function

Multiple CPU high speed refresh function is used as in the following applications. 1) Read the data such as the real current value and synchronous encoder current value with PLC CPU at high speed. 2) Exchange the FIN waiting signal at high speed.

Show 4 more labels / short text on this page
Display · Device setting · User setting · Points
Page 63 of the Mitsubishi Electronics Q172DCPU user manual — 2 MULTIPLE CPU SYSTEM
Page 63 · click to enlarge
Page 63

2 MULTIPLE CPU SYSTEM

(2) Operation example of Multiple CPU high speed refresh function

The automatic refresh setting of Multiple CPU high speed refresh is shown below.

  • CPU No.1 (PLC CPU) (GX Developer) Set the device transmitted to CPU No.2.
  • CPU No.2 (Motion CPU) (MT Developer) Set the device received from CPU No.1.
Mitsubishi Electronics Q172DCPU — 2 MULTIPLE CPU SYSTEM diagram (page 63)
Fig. 33

Set the device received from CPU No.2.

Set the device transmitted to CPU No.1.

Set the device to executed the Multiple CPU high speed refresh.

Mitsubishi Electronics Q172DCPU — 2 MULTIPLE CPU SYSTEM diagram (page 63)
Fig. 34
(Note)The operating example of Multiple CPU high speed refresh function is shown

in "(b) Operation example".

(a) Parameter setting

Page 64 of the Mitsubishi Electronics Q172DCPU user manual — 2 MULTIPLE CPU SYSTEM
Page 64 · click to enlarge
Page 64

2 MULTIPLE CPU SYSTEM

POINT Set the following operation for automatic refresh setting using GX Developer. 1) Select tab "Multiple CPU high speed communication area setting". 2) Set "Use Multiple CPU high speed communication ".

Mitsubishi Electronics Q172DCPU — 2 MULTIPLE CPU SYSTEM diagram (page 64)
Fig. 35

1) · 2)

Page 65 of the Mitsubishi Electronics Q172DCPU user manual — 2 MULTIPLE CPU SYSTEM
Page 65 · click to enlarge
Page 65

2 MULTIPLE CPU SYSTEM

The example of operating Multiple CPU high speed refresh function is shown below.

PLC CPU (CPU No.1)

Motion CPU (CPU No.2)

Mitsubishi Electronics Q172DCPU — 2 MULTIPLE CPU SYSTEM diagram (page 65)
Fig. 36
  • Axis 1 to 4 status information (M2400 to M2495) is transferred to the automatic refresh area one every operation cycle of the Motion CPU.
  • Axis 1 to axis 4 command signals are received from the automatic refresh area one every operation cycle of the Motion CPU.
  • Real current values of Axis 1 to axis 4 and M-code is updated by setting D0 to D639 of the Motion CPU to the automatic refresh area.
  • Every 0.88ms, data in the automatic refresh area of all CPUs are transferred allowing each CPU to update its data upon its next independent operation cycle.

(b) Operation example

Page 66 of the Mitsubishi Electronics Q172DCPU user manual — (4) Error
Page 66 · click to enlarge
Page 66

2 MULTIPLE CPU SYSTEM

2.3.4 Clock synchronization between Multiple CPU

The clock of each CPU is synchronized with the clock of CPU No. 1. The clock data used for synchronization in a Multiple CPU system can be edited.

(1) Setting of clock data

Set the clock of CPU No.1. The Motion CPU module operates automatically by the clock of CPU No.1.

POINT The clock data of CPU No.1 is automatically set even if the clocks of CPU No. 2 to 4 are set independently.

(2) Synchronization of clock data

All clocks are synchronized with CPU No.1 immediately after turning ON/resetting power and every 1-second interval thereafter.

(3) Information of clock

The clock data that CPU No. 1 transmits is year, month, day, day of week, hour, minute and second.

(4) Error

Since CPU No.1 sets the clock data at 1-second intervals, an error of up to 1 second may occur to the clock of CPU No.2 to 4.

Page 67 of the Mitsubishi Electronics Q172DCPU user manual — (1) Multiple CPU synchronous startup setting
Page 67 · click to enlarge
Page 67

2 MULTIPLE CPU SYSTEM

2.3.5 Multiple CPU synchronous startup

Multiple CPU synchronous startup function synchronizes the startups of CPU No.1 to CPU No.4. (It takes about ten seconds to startup for Motion CPU.) Since this function monitors the startup of each CPU module, when other CPU is accessed by a user program, an interlock program which checks the CPU module startup is unnecessary. With the Multiple CPU synchronous startup function, the startup is synchronized with the slowest CPU module to startup; therefore, the system startup may be slow.

POINT Multiple CPU synchronous startup function is for accessing each CPU module in a Multiple CPU system without needing an interlock. This function is not for starting an operation simultaneously among CPU modules after startup.

(1) Multiple CPU synchronous startup setting

To use the Multiple CPU synchronous startup function, check No.1 to No.4 of target CPU in Multiple CPU settings in system setting of MT Developer. (Set it in the Multiple CPU setting of PLC parameter setting of GX Developer for QnUD(H)CPU.) "Set Sync. startup setting of CPU " is set for No.1 to 4 at default.

Mitsubishi Electronics Q172DCPU — (1) Multiple CPU synchronous startup setting diagram (page 67)
Fig. 37 · (1) Multiple CPU synchronous startup setting

Set the same Multiple CPU synchronous startup for all CPUs that constitute the Multiple CPU system. The self-diagnosis error "PARAMETER ERROR (error code: 3015)" will occur if all CPU modules that constitute the Multiple CPU system do not have the same setting. When this function is not used (each CPU startup without synchronization), startup of each CPU module can be confirmed by using special relays SM220 to SM223 (CPU No.1 to 4 READY complete flag).

Page 68 of the Mitsubishi Electronics Q172DCPU user manual — PLC CPU Motion CPU
Page 68 · click to enlarge
Page 68

2 MULTIPLE CPU SYSTEM

2.3.6 Control Instruction from PLC CPU to Motion CPU

Control can be instructed from the PLC CPU to the Motion CPU using the Motion dedicated PLC instructions listed in the table below. Refer to the "Q173DCPU/Q172DCPU Motion controller (SV13/SV22) Programming Manual (Motion SFC)" for the details of each instruction. (Control may not be instructed from one Motion CPU to another Motion CPU.)

Mitsubishi Electronics Q172DCPU — 2 MULTIPLE CPU SYSTEM diagram (page 68)
Fig. 38

D(P).SFCS Start request of the Motion SFC program (Program No. may be specified.)

D(P).CHGA Current value change request of the specified axis

D(P).CHGT Torque control value change request of the specified axis

D(P).GINT Execute request of an event task to the other CPU (Motion CPU)

D(P).DDWR Write device data of the self CPU (PLC CPU) to the device of other CPU

D(P).DDRD Read device data of other CPU (Motion CPU) to the device of self CPU

For example, by using the D(P).SFCS instruction of Motion dedicated PLC instruction, the Motion SFC of the Motion CPU can be started from the PLC CPU.

PLC CPU Motion CPU

Mitsubishi Electronics Q172DCPU — PLC CPU Motion CPU diagram (page 68)
Fig. 39 · PLC CPU Motion CPU

Page 69 of the Mitsubishi Electronics Q172DCPU user manual — 2 MULTIPLE CPU SYSTEM
Page 69 · click to enlarge
Page 69

2 MULTIPLE CPU SYSTEM

MEMO

Page 70 of the Mitsubishi Electronics Q172DCPU user manual — 3 COMMON PARAMETERS
Page 70 · click to enlarge
Page 70

3 COMMON PARAMETERS

3. COMMON PARAMETERS

3.1 System Settings

In the Multiple CPU system, the common system parameters and individual parameters are set for each CPU and written to each CPU. (1) The base settings, Multiple CPU settings and Motion slot settings are set in the

common system parameter setting.

(2) The system basic setting, self CPU installation position setting, servo

amplifier setting, high-speed read setting and optional data monitor setting are set in the individual parameter setting.

(3) The data setting and correction can be performed in dialog form using MT

Developer.

Page 71 of the Mitsubishi Electronics Q172DCPU user manual — 3 COMMON PARAMETERS
Page 71 · click to enlarge
Page 71

3 COMMON PARAMETERS

3.1.1 System data settings

The table below lists the system data items to be set.

Item Setting range Initial value Remark

Main base 8/12 slots Main base: 8 slots Base setting

Set the number of slots in the main base or extension base.

Extension base None/2/3/5/8/10/12 slots None

No. of CPU 2/3/4 modules 2 modules Set the total number of Multiple CPUs including PLC CPU(s).

Stop/do not stop all CPUs upon an error in CPU No. 1 to 4. (The setting range varies depending on the number of Multiple CPUs.)

Set whether or not to stop the entire system when a CPU stop error occurs in each CPU.

Error operation mode at the stop of CPU

Stop all CPUs upon error in CPU Nos. 1 to 4

CPU specific send range

0 to 14k points Varies depending on the number of CPUs.

Multiple CPU high speed transmission area setting Automatic refresh setting

System area 1 to 2k points 1

Refer to Section 2.3.2.

Point2 to 14336 points Start : Set target device for

automatic refresh.

Set/do not set CPU No. 1 to 4 as the synchronized startup. (The setting range varies depending on the number of Multiple CPUs.)

Multiple CPU synchronous startup setting

Set CPU No. 1 to 4 as the synchronized startup. Refer to Section 2.3.5.

Install the modules controlled by the self CPU in the main base and/or extension base(s).

Module arrangement Within the main base and extension base slots None

Individual module Varies depending on the module. Varies depending on the module.

Set detailed items for each module controlled by the self CPU.

Operation cycle 0.4ms/0.8ms/1.7ms/3.5ms/7.1 ms/ 14.2ms/Auto Auto Set the operation cycle of motion control.

M2000 is turned on by switching from STOP to RUN./M2000 is turned on by switching from STOP to RUN and setting 1 in the set register.

M2000 is turned on by switching from STOP to RUN.

Operation at STOP to RUN

Set the condition in which the PLC ready flag (M2000) turns on.

Set the bit device to use forced stop in the program. However, the forced stop input by EMI terminal of Motion CPU module cannot be invalidated using parameter setting.

Forced stop (Note-1) None/X(PX) (0 to 1FFF)/ M (0 to 8191) None

M (0 to 8191)/B (0 to 1FFF)/ F (0 to 2047)/D (0 to 8191)/ W (0 to 1FFF)

None Set the latch range of device memory.

Set self CPU/other CPU/CPU (empty) for slots 0/1/2. (The setting range varies depending on the number of Multiple CPUs installed.)

None Set the installation position of the self CPU in the main base.

Self CPU installation position setting

Show 7 more labels / short text on this page
Multiple CPU setting · Common system parameters · None · Motion slot setting · System basic setting · Individual parameters · Latch range
Page 72 of the Mitsubishi Electronics Q172DCPU user manual — 3 COMMON PARAMETERS
Page 72 · click to enlarge
Page 72

3 COMMON PARAMETERS

Item Setting range Initial value Remark

Q173DCPUUp to 2 systems, 32 axes Q172DCPU: Up to 1 system, 8 axes

None Set the model name, axis No. and other details for the servo amplifiers.

Amplifier input invalid Amplifier setting

External signal input setting Amplifier input invalid/Amplifier input valid

Input filter setting None/0.8ms/1.7ms/2.6ms/3.5ms 3.5ms

High-speed data read setting One Q172DEX/Q173DPX module and one input module. None Set the high-speed read data. Refer to Section 4.3.

Set 1 to 3 for each axis. Q173DCPU: Up to 32 axes Q172DCPU: Up to 8 axes

None Set the optional data monitor. Refer to Section 4.10.

Optional data monitor setting

(Note-1) : The forced stop can also be executed by the EMI forced stop terminal of Motion CPU module or forced stop terminal of

servo amplifier besides the forced stop input setting.

Individual parameters

Page 73 of the Mitsubishi Electronics Q172DCPU user manual — Q172D CPU
Page 73 · click to enlarge
Page 73

3 COMMON PARAMETERS

3.1.2 Common system parameters

(1) Parameters for operating the Multiple CPU system

In the Multiple CPU system, the common system parameters and individual parameter for each CPU are set and written into each CPU. Regarding the Motion CPU, the items in System Settings related to the entire Multiple CPU system must be identical to the parameter settings in the PLC CPU.

Q173D CPU QnUD(H) CPU

Q172D CPU

Show 15 more labels / short text on this page
PLC CPU parameters · PLC CPU parameters · Motion CPU parameters · Motion CPU parameters · Common system parameters · Common system parameters · Common system parameters · Common system parameters · Individual parameter · Individual parameter · Individual parameter · Individual parameter · Parameter write · Power supply · QnUD(H) CPU
Page 74 of the Mitsubishi Electronics Q172DCPU user manual — 3 COMMON PARAMETERS
Page 74 · click to enlarge
Page 74

3 COMMON PARAMETERS

(2) Parameters common throughout the Multiple CPU system

In the Motion CPU, during initialization the parameters in the table below are verified against the parameters in the PLC CPU of CPU No. 1. Unmatched parameters generate a PARAMETER ERROR (error code: 3012, 3015), so the parameters show below must be set identically between Motion CPUs and the PLC CPU of CPU No.1. (If the system settings are changed in a Motion CPU, it is necessary to reset. Therefore, the parameters are checked only during initialization.) The parameter No. of unmatched parameter is set in the error individual information (SD16) by this error occurrence. PLC CPUs can use the parameters of the other CPUs via "Multiple CPU parameter utilization" of GX Developer. Since Motion CPUs don't have this function, however, the common parameters must be set for each Motion CPU. Table of Parameters cross-Multiple CPU system

Name in Motion CPU Name in PLC CPU

No. of CPU No. of PLC Number of CPUs 0E00H

Operating mode Operating mode Operation mode for CPU stop error 0E01H

CPU specific send range

CPU specific send range

Points of CPU specific send range E008H Refer to Section 2.3.2.

Refer to Section 2.3.2. This parameter can be set when "Advanced setting" is selected.

Multiple CPU high speed transmission area setting

Multiple CPU high speed transmission area setting

System area System area System area size E008H

Refer to Section 2.3.2. (Automatic refresh using Multiple CPU high speed transmission area)

Points of automatic refresh E009H

Multiple CPU synchronous startup setting

Multiple CPU synchronous startup setting

Synchronize Multiple CPU startup or not E00BH Refer to Section 2.3.5.

Motion slot setting Detailed settings Control PLC Control CPU No. 0406H Verify module only set in the system settings in the Motion CPU side.

Total number of bases

0401H Not verified if base settings are omitted in the PLC CPU side.

Base No. Base setting

Base Number of base

Show 10 more labels / short text on this page
Type of parameter · Verification item Parameter · number Remark · Multiple CPU setting · Multiple CPU settings · Automatic refresh setting · Automatic refresh setting · I/O assignment · Basic setting Slots · slots
Page 75 of the Mitsubishi Electronics Q172DCPU user manual — Multiple PLC Setting (PLC CPU setting) in GX Developer
Page 75 · click to enlarge
Page 75

3 COMMON PARAMETERS

(a) Multiple CPU settings

  • Set the following items identically in Multiple CPU Settings (Motion CPU) in MT Developer and in Multiple CPU Settings (PLC CPU) in GX Developer.
  • Number of CPU modules (Included CPU empty slots)
  • Operation mode when a CPU stop error occurred
  • Multiple CPU high speed transmission area setting (Must be set the same for all CPUs)
  • Multiple CPU synchronous startup setting

Multiple CPU Settings (Motion CPU) in MT Developer

Mitsubishi Electronics Q172DCPU — Multiple CPU Settings (Motion CPU) in MT Developer diagram (page 75)
Fig. 40 · Multiple CPU Settings (Motion CPU) in MT Developer

Number of CPU modules

Error operation mode at the stop of CPU

Multiple CPU high speed transmission area setting

Mitsubishi Electronics Q172DCPU — Multiple CPU Settings (Motion CPU) in MT Developer diagram (page 75)
Fig. 41 · Multiple CPU Settings (Motion CPU) in MT Developer

Multiple CPU synchronous startup setting

Multiple PLC Setting (PLC CPU setting) in GX Developer

Mitsubishi Electronics Q172DCPU — Multiple PLC Setting (PLC CPU setting) in GX Developer diagram (page 75)
Fig. 42 · Multiple PLC Setting (PLC CPU setting) in GX Develop…

Select tab "Multiple CPU high speed communication area setting"

Set "Use multiple CPU high speed communication".

Page 76 of the Mitsubishi Electronics Q172DCPU user manual — I/O Assignment Setting (PLC CPU setting) in GX Developer
Page 76 · click to enlarge
Page 76

3 COMMON PARAMETERS

(b) Motion slot settings

Set the modules controlled by the self CPU by the Motion Slot Settings (Motion CPU) in MT Developer. In GX Developer, set the slot for Motion CPU control as the CPU number of Motion CPU in I/O Assignment Settings (PLC CPU).

Motion Slot Setting (Motion CPU) in MT Developer

Mitsubishi Electronics Q172DCPU — Motion Slot Setting (Motion CPU) in MT Developer diagram (page 76)
Fig. 43 · Motion Slot Setting (Motion CPU) in MT Developer

Control CPU No.

I/O Assignment Setting (PLC CPU setting) in GX Developer

Mitsubishi Electronics Q172DCPU — I/O Assignment Setting (PLC CPU setting) in GX Developer diagram (page 76)
Fig. 44 · I/O Assignment Setting (PLC CPU setting) in GX Devel…

(Note): Motion slot setting items are different depending on the operating system software.

Page 77 of the Mitsubishi Electronics Q172DCPU user manual — I/O Assignment Settings (PLC CPU setting) in GX Developer
Page 77 · click to enlarge
Page 77

3 COMMON PARAMETERS

Set the total number of bases and number of slots in each base identically between Base Settings (Motion CPU) in MT Developer and I/O Assignment Settings (PLC CPU) in GX Developer. In GX Developer, the detailed settings may be omitted by setting the base mode "Automatic".

Base Settings (Motion CPU) in MT Developer

Mitsubishi Electronics Q172DCPU — Base Settings (Motion CPU) in MT Developer diagram (page 77)
Fig. 45 · Base Settings (Motion CPU) in MT Developer

Total number of bases and number of slots in each base

I/O Assignment Settings (PLC CPU setting) in GX Developer

Mitsubishi Electronics Q172DCPU — I/O Assignment Settings (PLC CPU setting) in GX Developer diagram (page 77)
Fig. 46 · I/O Assignment Settings (PLC CPU setting) in GX Deve…

(Note) : Only the Motion CPU may be set without setting the PLC CPU.

(c) Base settings

Page 78 of the Mitsubishi Electronics Q172DCPU user manual — 3 COMMON PARAMETERS
Page 78 · click to enlarge
Page 78

3 COMMON PARAMETERS

POINT GOT is recognized as an intelligent function modules "16 points 10 slots" on the base (number of extension bases and slot No. are set in the GOT parameter.) for bus connection with GOT. Set the one extension base (16 points 10 slots) for connection with GOT, then set "10 slots" as number of extension bases for connection with GOT in the system setting (base setting).

When the "2nd stage" of extension base is set as connection with GOT. (Set "10" slot as "2nd stage" of extension base in the base setting.)

Mitsubishi Electronics Q172DCPU — 3 COMMON PARAMETERS diagram (page 78)
Fig. 47

Page 79 of the Mitsubishi Electronics Q172DCPU user manual — 3 COMMON PARAMETERS
Page 79 · click to enlarge
Page 79

3 COMMON PARAMETERS

3.1.3 Individual parameters

(1) System basic setting

The following explains each item to be set in system basic setting.

Mitsubishi Electronics Q172DCPU — 3 COMMON PARAMETERS diagram (page 79)
Fig. 48
1. Set the of motion operation cycle (cycles at which a position command is computed and sent to the servo amplifier). The setting range is 0.4ms/0.8ms/1.7ms/3.5ms/7.1ms/14.2ms/Automatic setting. The actual operation cycle corresponding to 0.4ms is 0.444...ms. Similarly, 0.8ms corresponds to 0.888…ms, 1.7ms to 1.777...ms, 3.5ms to 3.555...ms, 7.1ms to 7.111...ms, and 14.2ms to 14.222…ms, respectively.
2. The default value is "Automatic Setting". When "Automatic Setting" is selected, the operation cycle is set according to the table below based on the number of axes for servo amplifier set in the System Settings.

Operating system Number of axes Operation cycle setting

1 to 6 axes 0.4 ms

7 to 18 axes 0.8 ms SV13

19 to 32 axes 1.7 ms

1 to 4 axes 0.4 ms

5 to 12 axes 0.8 ms

13 to 28 axes 1.7 ms SV22

29 to 32 axes 3.5 ms

(a) Operation cycle

Page 80 of the Mitsubishi Electronics Q172DCPU user manual — 3 COMMON PARAMETERS
Page 80 · click to enlarge
Page 80

3 COMMON PARAMETERS

3) If the duration of motion operation has exceeded the operation cycle, the operation cycle over flag (M2054) turns ON. Even when "Automatic setting" is selected, the duration of motion operation may exceed the operation cycle depending on the control conditions. The actual duration of motion operation (unit:μs) is stored in SD522, and the current setting of operation cycle (unit:μs) is stored in SD523. Monitor these special registers and adjust the set value of operation cycle so that the actual duration of motion operation will not exceed the set operation cycle. (A WDT or other error may occur in the Motion CPU.)

(b) Operation at STOP to RUN

Set the condition in which the "PLC ready" flag (M2000) turns ON. Select any one of the followings. 1) M2000 is turned on by switching from STOP to RUN. Condition in which the M2000 turns from OFF to ON

  • Change the RUN/STOP switch from STOP to RUN.
  • Turn ON the power supply with the RUN/STOP switch set to RUN.

Condition in which the M2000 turns from ON to OFF

  • Change the RUN/STOP switch from RUN to STOP.
2. M2000 is turned on by switching from STOP to RUN and setting 1 in the set register.

(M2000 turns ON when the switch is set to RUN and 1 is set in the setting register.)

Condition in which the M2000 turns from OFF to ON

  • With the RUN/STOP switch set to RUN, set 1 in the setting register for "PLC ready" flag (D704). (The Motion CPU detects a change from 0 to 1 in the lowest bit in the D704).

Condition in which the M2000 turns from ON to OFF

  • With the RUN/STOP switch set to RUN, set 0 in the setting register for "PLC ready" flag (D704). (The Motion CPU detects a change from 1 to 0 in the lowest bit in the D704).
  • Change the RUN/STOP switch from RUN to STOP.
  • Set the bit device used for executing a forced stop in which all servoamplifier axes are stopped immediately in the program. Either X (PX) or M can be specified. No default value has been set. The set bit device is designated as contact B and performs the following control in response to ON/OFF of the device.
  • Bit device is turned OFF …Forced stop input is ON (forced stop)
  • Bit device is turned ON …..Forced stop input is OFF (forced stop is released.) The forced stop input by EMI terminal of Motion CPU module cannot be invalidated using parameter setting.

(c) Forced stop

Page 81 of the Mitsubishi Electronics Q172DCPU user manual — Setting items for each module
Page 81 · click to enlarge
Page 81

3 COMMON PARAMETERS

  • Set the following latching ranges for M, B, F, D and W, respectively.
  • Latch (1) : It is possible clear using the remote operation (Latch clear(1), Latch clear (1)(2)).
  • Latch (2) : It is possible clear using the remote operation (Latch clear (1)(2)).

(2) Individual module settings

The setting items for each module are shown below.

Setting items for each module

Mitsubishi Electronics Q172DCPU — Setting items for each module diagram (page 81)
Fig. 49 · Setting items for each module

Number of usable modules Module name Item Setting range Initial value

External signal setting Set the number of axes for which the 8 axes input is used. Unused

DOG Valid on leading edge/ Valid on trailing edge

QI60 Interrupt module Input response time 0.1/0.2/0.4/0.6/1 ms 0.2 ms 1 1

(d) Latch range

Page 82 of the Mitsubishi Electronics Q172DCPU user manual — Q6 DA / Q6 DA-
Page 82 · click to enlarge
Page 82

3 COMMON PARAMETERS

Setting items for each module (Continued)

Number of usable modules Module name Item Setting range Initial value

Q173DCPU Q172DCPU

First I/O No. 00 to FF0 (in units of 16 points) 0

High-speed data read setting Used/Unused Unused QX Input module

I/O response time (setting for high-speed input module in parentheses)

1/5/10/20/70 ms (0.1/0.2/0.4/0.6/1 ms)

10 ms (0.2 ms)

First I/O No. 00 to FF0 (in units of 16 points) 0 QY Output module

First I/O No. 00 to FF0 (in units of 16 points) 0

Input/Output composite module High-speed data read setting Used/Unused Unused

I/O response time 1/5/10/20/70 ms 10 ms QH / QX Y

First I/O No. 00 to FF0 (in units of 16 points) 0

Input range 4 to 20mA/0 to 20mA/1 to 5V/0 to 5V/-10 to 10V/0 to 10V/User range 4 to 20mA

Total 256 points or less

Total 256 points or less

Q6 AD / Q6 AD-

Temperature drift compensation Used/None Used

Resolution mode Normal/High Normal

Operation mode Normal (A/D conversion)/Offset gain setting

(A/D conversion) First I/O No. 00 to FF0 (in units of 16 points) 0

Output range 4 to 20mA/0 to 20mA/1 to 5V/0 to 5V/-10 to 10V/User range 4 to 20mA

HOLD/CLEAR function CLEAR only CLEAR

Q6 DA / Q6 DA-

Output mode Normal (Asynchronous)/ Synchronous output

(Asyn- chronous) Resolution mode Normal/High Normal

Operation mode Normal (D/A conversion)/ Offset gain setting

Show 9 more labels / short text on this page
Point 0/16/32/64/128/256 16 · Point 0/16/32/64/128/256 16 · Point 0/16/32/64/128/256 16 · Analogue input module · Normal · Normal · Analogue output module · Normal · (D/A conversion)
Page 83 of the Mitsubishi Electronics Q172DCPU user manual — 3 COMMON PARAMETERS
Page 83 · click to enlarge
Page 83

3 COMMON PARAMETERS

(3) External signal input

Servo external signal (Upper stroke limit/Lower stroke limit/Stop signal/Proximity dog) can be selected for every axis from the following two methods.

(a) Q172DLX Servo external signals interface module use

Set the servo external signals interface module, and set axis No. as the "External signal setting" in the system setting.

(b) Servo amplifier input device use (MR-J3-†B use only)

  • Set "Amplifier input valid" as the external signal input setting in the "Amplifier setting" of system setting. There are following restrictions to use.
  • Count type home position return cannot be used.
  • Speed/position switching control cannot be executed.
  • Stop signal (STOP) cannot be used.

The correspondence of external signal and input device is shown below.

External signals Input device (CN3) (Note)

Upper stroke limit (FLS) DI1

Lower stroke limit (RLS) DI2

Proximity dog (DOG) DI3

(Note): Refer to the "MR-J3-†B Servo Amplifier Instruction Manual" for pin configurations.

Set the external signal setting in the "Input Filter Setting".

Page 84 of the Mitsubishi Electronics Q172DCPU user manual — REMARK
Page 84 · click to enlarge
Page 84

3 COMMON PARAMETERS

3.2 I/O number assignment

In the Multiple CPU system, I/O numbers are used for interactive transmission between the Motion CPU and I/O modules and intelligent function modules, or between PLC CPU and Motion CPU. 3.2.1 I/O number assignment of each module

The Multiple CPU system is different from the Single CPU system in the position (slot) of I/O number "0H" for PLC CPU. However, I/O number of control module can be assigned independently for each CPU for Motion CPU.

(1) Position of I/O number "0H"

(a) The number of slots set with the Multiple CPU settings are occupied by the

PLC CPU/Motion CPU on the Multiple CPU system.

(b) I/O modules and intelligent function modules are installed from the right of the

slots occupied by PLC CPU/Motion CPU.

(c) I/O number of Motion CPU control module can be assigned independently for

each CPU. The I/O number of PLC CPU control module for an I/O module or intelligent function module mounted to the next slot to those occupied by CPU modules is set as "0H" and consecutive numbers are then allocated sequentially to the right.

(d) Notation of I/O number

  • Receiving of ON/OFF data by Motion CPU is deemed input (PX), while outputting of ON/OFF data from Motion CPU is deemed output (PY).
  • I/O number is expressed in hexadecimal.

REMARK

1. If the number of CPU modules installed on the main base unit is less than the number set at the "Multiple CPU setting", set the open slot(s) to "PLC (Empty)". Refer to Section 2.1.2 for the "PLC (Empty)" setting. 2) The I/O numbers for the Multiple CPU system can be confirmed with the system monitor of GX Developer.
Page 85 of the Mitsubishi Electronics Q172DCPU user manual — (3) Setting of the Motion CPU control modules by the PLC CPU
Page 85 · click to enlarge
Page 85

3 COMMON PARAMETERS

(2) I/O number assignment of Motion CPU control module

Mitsubishi recommends that I/O No. assignment be set as common consecutive No. throughout all CPUs. However, the I/O number of the input modules, output modules and input/output composite modules controlled with the Motion CPU can also be set regardless as the I/O number of PLC CPU. (I/O number of the Motion CPU control modules is indicated as PX/PY.) I/O number of the Motion CPU control modules cannot be assigned by I/O assignment settings of PLC CPU.

Mitsubishi Electronics Q172DCPU — 3 COMMON PARAMETERS diagram (page 85)
Fig. 50

CPU No. 1 CPU No. 2 CPU No. 2

CPU No. 2

CPU No. 1

CPU No. 1

(3) Setting of the Motion CPU control modules by the PLC CPU

Follow the table below when Motion CPU control modules are set in I/O Assignment Settings of the PLC CPU. (The PLC CPU handles the Q172DLX, Q172DEX and Q173DPX as intelligent function modules having 32 occupied points.) Type and number of points may be left unset.

Mitsubishi Electronics Q172DCPU — (3) Setting of the Motion CPU control modules by the PLC CPU diagram (page 85)
Fig. 51 · (3) Setting of the Motion CPU control modules by the…
Mitsubishi Electronics Q172DCPU — (3) Setting of the Motion CPU control modules by the PLC CPU diagram (page 85)
Fig. 52 · (3) Setting of the Motion CPU control modules by the…

POINT (1) Set the I/O device of the Motion CPU within the range from PX/PY000 to

PX/PYFFF. Set the number of real I/O points within 256 points. (I/O No. may not be consecutive.) (2) As for the Motion CPU, the Q172DLX, Q172DEX, Q173DPX and QI60 are not

Show 5 more labels / short text on this page
I/O assignment · control module · control module · control module · control module
Page 86 of the Mitsubishi Electronics Q172DCPU user manual — 3 COMMON PARAMETERS
Page 86 · click to enlarge
Page 86

3 COMMON PARAMETERS

3.2.2 I/O number of each CPU modules

In the Multiple CPU system, I/O numbers are assigned to each CPU module to specify installed CPU modules. The I/O number for each CPU module is fixed to the corresponding slot and cannot be changed. The I/O number allocated to each CPU module in the Multiple CPU system is shown below.

CPU module installation position CPU slot Slot 0 Slot 1 Slot 2

First I/O number 3E00H 3E10H 3E20H 3E30H

  • The I/O number of PLC CPU/Motion CPU are used in the following cases.
  • When writing data to the CPU shared memory of self CPU using the S. TO instruction.
  • When reading data from the CPU shared memory of other CPU using the FROM instruction.
  • When reading data from the CPU shared memory of other CPU using an intelligent function module device (U \G )
  • When reading device data directly from the Motion CPU from the PLC CPU using the "D(P).DDRD" instruction.
  • When writing device data directly to the Motion CPU from the PLC CPU using the "D(P).DDWR" instruction. Refer to Section 2.3.6 or the "Q173DCPU/Q172DCPU Motion controller (SV13/SV22) Programming Manual (Motion SFC)" for the Motion dedicated PLC instruction.
Page 87 of the Mitsubishi Electronics Q172DCPU user manual — 3 COMMON PARAMETERS
Page 87 · click to enlarge
Page 87

3 COMMON PARAMETERS

3.2.3 I/O number setting

  • Set the modules installed in the each slot of the main base or extension base and assign the control CPU of applicable slot as the self CPU in the system setting for Motion CPU. The following modules must be set the I/O No..
  • Input module
  • Output module
  • Input/Output composite module
  • Analogue input module
  • Analogue output module Refer to the help of MT Developer for the detailed operating procedure on the system settings screen.

Set the I/O No. of modules controlled with the Motion CPU module set in the system structure screen of MT Developer. The setting procedure of I/O No. is shown below.

(Example) For set the output module

Mitsubishi Electronics Q172DCPU — 3 COMMON PARAMETERS diagram (page 87)
Fig. 53
1. Double-click the slot position, display the Motion Slot Settings screen.
Mitsubishi Electronics Q172DCPU — 3 COMMON PARAMETERS diagram (page 87)
Fig. 54
2. Select the I/O module.
3. Click [Detail Setting].
Mitsubishi Electronics Q172DCPU — 3 COMMON PARAMETERS diagram (page 87)
Fig. 55
4. Set the first I/O No. (PX No., PY No.).
5. Select applicable module type and number of points for the I/O module to be used.
6. Click [OK].

(Note): Display of system setting and motion slot setting are different depending on the operating system

software.

POINT I/O No.s cannot be assigned automatically, unlike a PLC CPU for which I/O No. are assigned automatically if such setting is omitted in the Motion CPU. In the Motion CPU, be sure to set the first I/O No. in System Settings for each module used.

· ·

Page 88 of the Mitsubishi Electronics Q172DCPU user manual — (1) Basic setting parameters
Page 88 · click to enlarge
Page 88

3 COMMON PARAMETERS

3.3 Servo Parameters

The servo parameters control the data fixed by the specifications of the servo amplifier and servomotor controlled in the parameter set for each axis and the control of the servomotor. The servo parameters are set by the Setup software (MR Configurator). Refer to the "Servo amplifier Instruction Manual" for details of the servo parameters. Refer to the help for handling of MR Configurator. Instruction Manual list is shown below.

Mitsubishi Electronics Q172DCPU — 3 COMMON PARAMETERS diagram (page 88)
Fig. 56

MR-J3- B-RJ006 Fully closed loop control MR-J3- B-RJ006 Servo Amplifier Instruction Manual (SH-030056)

(1) Basic setting parameters

Mitsubishi Electronics Q172DCPU — (1) Basic setting parameters diagram (page 88)
Fig. 57 · (1) Basic setting parameters

POINTS (1) When the items marked " " in the above table has changed, make the Multiple CPU system reset or power supply OFF to ON. And, once turn OFF the servo amplifier power supply and then turn ON it again.

Mitsubishi Electronics Q172DCPU — (1) Basic setting parameters diagram (page 88)
Fig. 58 · (1) Basic setting parameters
Page 89 of the Mitsubishi Electronics Q172DCPU user manual — PB41 1125
Page 89 · click to enlarge
Page 89

3 COMMON PARAMETERS

(2) Gain/filter parameters

No. Symbol Name Initial value Unit

PB01 FILT Adaptive tuning mode (Adaptive filter ) 0000h —

PB02 VRFT Vibration suppression control tuning mode (Advanced vibration suppression control) 0000h —

PB03 — For manufacturer setting 0 —

PB04 FFC Feed forward gain 0 %

PB05 — For manufacturer setting 500 —

PB06 GD2 Ratio of load inertia moment to servomotor inertia moment 7.0 times

PB07 PG1 Model loop gain 24 rad/s

PB08 PG2 Position loop gain 37 rad/s

PB09 VG2 Speed loop gain 823 rad/s

PB10 VIC Speed integral compensation 33.7 ms

PB11 VDC Speed differential compensation 980 —

PB12 — For manufacturer setting 0 —

PB13 NH1 Machine resonance suppression filter 1 4500 Hz

PB14 NHQ1 Notch shape selection 1 0000h —

PB15 NH2 Machine resonance suppression filter 2 4500 Hz

PB16 NHQ2 Notch shape selection 2 0000h —

PB17 — Automatic setting parameter — —

PB18 LPF Low pass filter setting 3141 rad/s

PB19 VRF1 Vibration suppression control - vibration frequency setting 100.0 Hz

PB20 VRF2 Vibration suppression control - resonance frequency setting 100.0 Hz

PB21 0.00

— For manufacturer setting

PB22

PB23 VFBF Low pass filter selection 0000h —

PB24 MVS Slight vibration suppression control selection 0000h —

PB25 — For manufacturer setting 0000h —

PB26 CDP Gain changing selection 0000h —

PB27 CDL Gain changing condition 10 —

PB28 CDT Gain changing time constant 1 ms

PB29 GD2B Gain changing - ratio of load inertia moment to servo motor inertia moment 7.0 times

PB30 PG2B Gain changing - position loop gain 37 rad/s

PB31 VG2B Gain changing - speed loop gain 823 rad/s

PB32 VICB Gain changing - speed integral compensation 33.7 ms

PB33 VRF1B Gain changing - vibration suppression control - vibration frequency setting 100.0 Hz

PB34 VRF2B Gain changing - vibration suppression control - resonance frequency setting 100.0 Hz

PB35 0.00

PB36 0.00

PB37 100

PB38 0.0

PB39 0.0

PB40 0.0

— For manufacturer setting

PB41 1125

PB42 1125

PB44 0.0

PB45

POINTS (1) When the items marked " " in the above table has changed, make the Multiple CPU system reset or power supply OFF to ON. And, once turn OFF the servo amplifier power supply and then turn ON it again.

PB43 0004h · 0000h

Page 90 of the Mitsubishi Electronics Q172DCPU user manual — 3 COMMON PARAMETERS
Page 90 · click to enlarge
Page 90

3 COMMON PARAMETERS

(3) Extension setting parameters

Mitsubishi Electronics Q172DCPU — 3 COMMON PARAMETERS diagram (page 90)
Fig. 59

PC13 MOSDL Analog monitor feedback position output standard data Low 0 PLS

PC14 MOSDH Analog monitor feedback position output standard data High 0 10000PLS

POINTS (1) When the items marked " " in the above table has changed, make the Multiple CPU system reset or power supply OFF to ON. And, once turn OFF the servo amplifier power supply and then turn ON it again.

Mitsubishi Electronics Q172DCPU — 3 COMMON PARAMETERS diagram (page 90)
Fig. 60
Page 91 of the Mitsubishi Electronics Q172DCPU user manual — 3 COMMON PARAMETERS
Page 91 · click to enlarge
Page 91

3 COMMON PARAMETERS

(4) I/O Setting Parameters

Mitsubishi Electronics Q172DCPU — 3 COMMON PARAMETERS diagram (page 91)
Fig. 61

PD07 DO1 Output signal device selection 1 (CN3-13) 0005h —

PD08 DO2 Output signal device selection 2 (CN3-9) 0004h —

PD09 DO3 Output signal device selection 3 (CN3-15) 0003h —

POINTS (1) When the items marked " " in the above table has changed, make the Multiple CPU system reset or power supply OFF to ON. And, once turn OFF the servo amplifier power supply and then turn ON it again.

Mitsubishi Electronics Q172DCPU — 3 COMMON PARAMETERS diagram (page 91)
Fig. 62
Page 92 of the Mitsubishi Electronics Q172DCPU user manual — ON
Page 92 · click to enlarge
Page 92

4 AUXILIARY AND APPLIED FUNCTIONS

4. AUXILIARY AND APPLIED FUNCTIONS

4.1 Limit Switch Output Function

This function is used to output the ON/OFF signal corresponding to the data range of the watch data set per output device. Motion control data or optional word data can be used as watch data. (Refer to Section "4.1.2 Limit output setting data" for details.) A maximum output device for 32 points can be set regardless of the number of axes. 4.1.1 Operations

(1) ON output to an output device is made while the watch data value is in the ON

output region set with (ON Value) and (OFF Value) in this function. (a) (ON Value), (OFF Value) and watch data value are handled as signed data.

ON output region where an ON output is made to the output device is governed by the magnitude relationship between (ON Value) and (OFF Value) as indicated below.

Relationship between (ON Value) and

(OFF Value) ON output region

(ON Value) < (OFF Value) (ON Value)

(ON Value) > (OFF Value) (ON Value)

(Watch data value) < (OFF Value)

(ON Value) = (OFF Value) Output OFF in whole region

1. (ON Value) < (OFF Value)

ON

OFF

OFF

(ON Value) (Watch data value) (OFF Value)

2. (ON Value) > (OFF Value)

ON

ON

OFF

(Watch data value) (OFF Value) (ON Value) (Watch data value)

Show 10 more labels / short text on this page
Output device · OFF Value · ON region setting · ON Value · Watch data value · Output device · ON Value · ON region setting · OFF Value · Watch data value
Page 93 of the Mitsubishi Electronics Q172DCPU user manual — ON
Page 93 · click to enlarge
Page 93

4 AUXILIARY AND APPLIED FUNCTIONS

3. (ON Value) = (OFF Value)

OFF in whole region

ON Value OFF Value

(b) The limit switch outputs are controlled based on the each watch data during

the PCPU ready status (SM500: ON) by the PLC ready flag (M2000) from OFF to ON. When the PCPU ready flag (SM500) turns OFF by turning the PLC ready flag (M2000) from ON to OFF, all points turn OFF. When (ON Value) and (OFF Value) are specified with word devices, the word device contents are input to the internal area when the PLC ready flag (M2000) turns from OFF to ON. After that, the word device contents are input per motion operation cycle, and limit switch outputs are controlled.

(c) Multiple outputs (Up to 32 points) can be also set to one watch data. In each

setting, the output device may be the same. If multiple ON region settings have been made to the same output device, the logical add of the output results in the regions is output.

ON

ON

OFF

OFF

ON region setting No.2

ON region setting No.1

(2) Output enable/disable bit can be set and executed enable/disable of the limit

switch outputs point-by-point. Limit switch output control is executed when the output enable/disable bit is ON, and the output is OFF when it is OFF. If there is no setting, the outputs are always enabled.

(3) Forced output bit can be set and turned the forcibly output of the limit switch

outputs point-by-point ON. The output is ON when the forced output bit is ON. Priority is given to control of this setting over off (disable) of the "output enable/disable bit". If there is no setting, no forced outputs are not always made.

Show 9 more labels / short text on this page
Output device · ON region setting · Watch data value · Output device · OFF Value · ON Value · OFF Value · ON Value · Watch data value
Page 94 of the Mitsubishi Electronics Q172DCPU user manual — 4 AUXILIARY AND APPLIED FUNCTIONS
Page 94 · click to enlarge
Page 94

4 AUXILIARY AND APPLIED FUNCTIONS

(4) When the multiple watch data, ON region, output enable/disable bit and forced

output bit are set to the same output device, the logical add of output results of the settings is output.

Mitsubishi Electronics Q172DCPU — 4 AUXILIARY AND APPLIED FUNCTIONS diagram (page 94)
Fig. 63

Output ON (Forced output) Output control based on ON Value and OFF Value

Output control based on ON Value and OFF Value Output OFF

Page 95 of the Mitsubishi Electronics Q172DCPU user manual — (1) Output device
Page 95 · click to enlarge
Page 95

4 AUXILIARY AND APPLIED FUNCTIONS

4.1.2 Limit output setting data

Limit output data list are shown below. Up to 32 points of output devices can be set. (The following items of No.1 to No.5 are set together as one point.)

Mitsubishi Electronics Q172DCPU — 4 AUXILIARY AND APPLIED FUNCTIONS diagram (page 95)
Fig. 64

1 Output device Bit device (X, Y, M, B, U \G) — Operation

ON Value Word device (D, W, #, U \G)/constant (K, H) 3 ON region

setting OFF Value Word device (D, W, #, U \G)/constant (K, H)

Bit device (X, Y, M, B, F, SM, U \G)/ none

5 Forced output bit Bit device (X, Y, M, B, F, SM, U \G)/ none

(1) Output device

(a) Set the bit device which outputs the ON/OFF signal toward the preset watch

data.

(b) As the output device, the following devices can be used.

Mitsubishi Electronics Q172DCPU — (1) Output device diagram (page 95)
Fig. 65 · (1) Output device

Input relay (Note-1) X0 to X1FFF Output relay (Note-2) Y0 to Y1FFF Internal relay (Note-3) M0 to M8191

Multiple CPU area device U \G10000.0 to U \G (10000+p-1).F (Note-4), (Note-5)

(Note-1) : PX is write-disabled and it cannot be used as the output device.

For X, only the free No. of the input card non-loading can be used.

(Note-2) : The real output device range (PY) is also included.

(Note-3) : M2001 to M2032 cannot be used to the output device.

Be careful because it affect a positioning operation, when the positioning

dedicated devices are set.

(Note-4)"p" indicates the user setting area points of the Multiple CPU high speed

transmission area for the each CPU.

(Note-5) : Only device of the self CPU can be used.

Page 96 of the Mitsubishi Electronics Q172DCPU user manual — 4 AUXILIARY AND APPLIED FUNCTIONS
Page 96 · click to enlarge
Page 96

4 AUXILIARY AND APPLIED FUNCTIONS

(2) Watch data

(a) This data is used to perform the limit switch output function. This data is

comparison data to output the ON/OFF signal. The output device is ON/OFF-controlled according to the ON region setting.

(b) As the watch data, motion control data or optional word device data can be

used.

1. Motion control data
Mitsubishi Electronics Q172DCPU — 4 AUXILIARY AND APPLIED FUNCTIONS diagram (page 96)
Fig. 66
2. Word device data
Mitsubishi Electronics Q172DCPU — 4 AUXILIARY AND APPLIED FUNCTIONS diagram (page 96)
Fig. 67

Multiple CPU area device U \G10000 to U \G (10000+p-1) (Note-1)

(Note-1)"p" indicates the user setting area points of the Multiple CPU high speed

transmission area for the each CPU.

3. When the optional device data is set, the following data type is set as the data type to be compared.
Mitsubishi Electronics Q172DCPU — 4 AUXILIARY AND APPLIED FUNCTIONS diagram (page 96)
Fig. 68

64-bit floating-point type Set the device No. as an even No..

Page 97 of the Mitsubishi Electronics Q172DCPU user manual — (4) Output enable/disable bit
Page 97 · click to enlarge
Page 97

4 AUXILIARY AND APPLIED FUNCTIONS

(3) ON region setting

(a) The data range which makes the output device turn ON/OFF toward the

watch data.

(b) The following devices can be used as the ON Value and OFF Value of the

data range. The data type of device/constant to be set is the same as the type of watch data.

Mitsubishi Electronics Q172DCPU — 4 AUXILIARY AND APPLIED FUNCTIONS diagram (page 97)
Fig. 69

Multiple CPU area device U \G10000 to U \G (10000+p-1) (Note-1)

(Note-1)"p" indicates the user setting area points of the Multiple CPU high speed

transmission area for the each CPU.

(4) Output enable/disable bit

(a) Set the status of output enable/disable bit when the limit switch output is

forbidden during operation.

1. The following control is exercised.
Mitsubishi Electronics Q172DCPU — (4) Output enable/disable bit diagram (page 97)
Fig. 70 · (4) Output enable/disable bit

Limit switch output is turned ON/OFF based on the ON

Mitsubishi Electronics Q172DCPU — (4) Output enable/disable bit diagram (page 97)
Fig. 71 · (4) Output enable/disable bit

Multiple CPU area device U \G10000.0 to U \G (10000+p-1).F (Note-3)

(Note-1) : The real input range(PX) is included.

(Note-2) : The real input range(PY) is included.

(Note-3)"p" indicates the user setting area points of the Multiple CPU high speed

transmission area for the each CPU.

(b) Usable devices

Page 98 of the Mitsubishi Electronics Q172DCPU user manual — OFF
Page 98 · click to enlarge
Page 98

4 AUXILIARY AND APPLIED FUNCTIONS

(5) Forced output bit

(a) Set the "forced output bit" when you want to forcibly provide the limit switch

outputs during operation.

1. The following control is exercised.

Output enable/disable bit Control description

Limit switch outputs are turned ON/OFF on the basis of

the "output enable/disable bit" and ON region setting

OFF

(ON Value, OFF Value). With setting

ON Limit switch outputs are turned ON.

Item Device No. setting range

Input relay X0 to X1FFF

Output relay Y0 to Y1FFF

Internal relay M0 to M8191

Link relay B0 to B1FFF

Annunciator F0 to F2047

Special relay SM0 to SM1999

Multiple CPU area device U \G10000.0 to U \G (10000+p-1).F (Note-1)

(Note-1)"p" indicates the user setting area points of the Multiple CPU high speed

transmission area for the each CPU.

POINT Refer to Chapter 2 for the user setting area points of the Multiple CPU high speed

transmission area.

Without setting · (b) Usable devices

Page 99 of the Mitsubishi Electronics Q172DCPU user manual — CAUTION
Page 99 · click to enlarge
Page 99

4 AUXILIARY AND APPLIED FUNCTIONS

4.2 Absolute Position System

The positioning control for absolute position system can be performed using the absolute-position-compatible servomotors and servo amplifiers. If the machine position is set at the system starting, home position return is not necessary because the absolute position is detected at the power on. The machine position is set with the home position return using the Motion SFC program or MT Developer. (1) Conditions of the absolute position system start

Perform a home position return after machine adjustment at the absolute position system start.

(2) In the absolute positioning system, the absolute position may be lost in the

following cases: Set the absolute position with a home position return. (a) The battery unit is removed or replaced.

(b) The battery error of the servo amplifier occurs. (It is detected at the servo

amplifier power on).

(c) The machine system is disturbed by a shock.

(d) The cable between servo amplifier and encoder is removed, or the servo

amplifier or encoder is replaced.

(3) The current value history can be monitored using of the "System setting mode-

allowable travel during power off" or "Monitor mode" using a MT Developer. (Refer to the help of MT Developer to be used "Allowable travel during power off" and "Monitor mode".)

CAUTION

After removing or replacing the battery unit, correctly install the new unit and set the absolute

position.

After a servo battery error occurs, eliminate the cause of the error and ensure operation is safe

before setting the absolute position.

After the mechanical system is disturbed by a shock, make the necessary checks and repairs,

and ensure operation is safe before setting the absolute position.

Page 100 of the Mitsubishi Electronics Q172DCPU user manual — 4 AUXILIARY AND APPLIED FUNCTIONS
Page 100 · click to enlarge
Page 100

4 AUXILIARY AND APPLIED FUNCTIONS

POINT (1) The address setting range of absolute position system is 2147483648 to

2147483647. It is not possible to restore position commands that exceed this limit, or current values after a power interruption. Correspond by the [degree] setting for an infinite feed operation. (2) Even when the current value address is changed by a current value change

instruction, the restored data for the current value after a power interruption is the value based on the status prior to execution of the current value change instruction. (3) When home position return has not been completed (home position return

request is ON), restoration of the current value after a power interruption is not possible.

Page 101 of the Mitsubishi Electronics Q172DCPU user manual — 4 AUXILIARY AND APPLIED FUNCTIONS
Page 101 · click to enlarge
Page 101

4 AUXILIARY AND APPLIED FUNCTIONS

4.2.1 Current value control

The current value when using the ABS encoder is controlled by following functions. (1) The validity of an encoder data during operation is checked.

(a) Checks that the amount of change of the encoder in a 3.5[ms] is within 180

degrees at the motor axis. (An error is displayed at the abnormal.)

(b) Checks that adjustment of the encoder data and feed-back positions

controlled with the servo amplifier. (An error is displayed at the abnormal.)

(2) The following values can be monitored by the current value history monitor of

MT Developer.

Monitor conditions Monitor value

Multiple CPU system power ON/OFF

Encoder current value, Servo command value, Monitor current value

Home position return completion

(a) Current value history monitor

The time such as at the completion of home position return and servo amplifier power supply ON/OFF is indicated. In order to indicate the time correctly, turn on SM801 (clock data read request) in the Motion SFC program after setting the clock data of special register.

(b) Encoder current value

When using the MR-J3- B, the multiple revolution data and within-one- revolution data read from the encoder is indicated. (Note) : For the encoder current value in the home position data area, the

encoder current value when the motor is within the in-position range at the completion of home position return is displayed (not encoder value of home position).

(c) Servo command value

The command value issued to the servo amplifier is indicated.

(d) Monitor current value

The current value controlled in the Motion CPU is indicated. (Note) : A value near the feed current value is indicated. However, because

the monitor current value and feed current value are different data, it is not abnormal even if a different value is indicated.

When an error for current value restoration occurs at the servo amplifier power on, an error code is indicated.

(3) By setting of the "Allowable travel during power off", if the encoder data changes

exceeding the setting range during power-off, it checks at servo amplifier power- on. (An error is displayed at the abnormal.) "Allowable travel during power off" cannot be set for the Linear servo amplifier.

Month/day/hour/minute · (e) Alarms

Page 102 of the Mitsubishi Electronics Q172DCPU user manual — (3) Usable devices
Page 102 · click to enlarge
Page 102

4 AUXILIARY AND APPLIED FUNCTIONS

4.3 High-Speed Reading of Specified Data

This function is used to store the specified positioning data in the specified device (D, W, U \G). The signal from input module controlled in the Motion CPU is used as a trigger. It can be set in the system setting of MT Developer. (1) Positioning data that can be set

Mitsubishi Electronics Q172DCPU — 4 AUXILIARY AND APPLIED FUNCTIONS diagram (page 102)
Fig. 72

Position command (Feed current value) 2 10-1[µm], 10-5[inch], 10-5[degree], [PLS]

Actual current value 2 10-1[µm], 10-5[inch], 10-5[degree], [PLS]

Virtual servo M-code 1 Current value after main shaft differential gear 2 [PLS]

Current value within one revolution of cam axis 2 [PLS]

Execute cam No. 1 Execute stroke amount 2 10-1[µm], 10-5[inch] [PLS]

(2) Modules and signals to be used

Mitsubishi Electronics Q172DCPU — (2) Modules and signals to be used diagram (page 102)
Fig. 73 · (2) Modules and signals to be used

Input module Signal Read timing Number of settable points

(Note) : Only one PLC input module can be used.

(3) Usable devices

Mitsubishi Electronics Q172DCPU — (3) Usable devices diagram (page 102)
Fig. 74 · (3) Usable devices

U \G 10000 to (10000 + p-1) (Note-1), (Note-2)

(Note-1)"p" indicates the user setting area points of the Multiple CPU high speed

transmission area for the each CPU. (Note-2): Only device of the self CPU can be used.

Mitsubishi Electronics Q172DCPU — (3) Usable devices diagram (page 102)
Fig. 75 · (3) Usable devices

POINT (1) Set an even number as device setting in the two word data. (2) Refer to Chapter 2 for the user setting area points of the Multiple CPU high

Page 103 of the Mitsubishi Electronics Q172DCPU user manual — (1) Operation mode
Page 103 · click to enlarge
Page 103

4 AUXILIARY AND APPLIED FUNCTIONS

4.4 ROM Operation Function

This function is used to operate based on the data in the FLASH ROM built-in Motion CPU module that the user programs and parameters have been stored. 4.4.1 Specifications of 7-segment LED/Switches

Mitsubishi Electronics Q172DCPU — 4 AUXILIARY AND APPLIED FUNCTIONS diagram (page 103)
Fig. 76
Mitsubishi Electronics Q172DCPU — 4 AUXILIARY AND APPLIED FUNCTIONS diagram (page 103)
Fig. 77
1. 7-segment LED • Indicate the operation state and error information.
  • Set the operation mode (Normal mode, Installation mode and mode operated by ROM, etc.)
  • Each switch setting is 0 to F.

(1) Operation mode

"Operation mode" of the Motion CPU is set by the rotary switch setting of Motion CPU module at the power supply ON of the Multiple CPU system. The rotary switch setting, operation mode and operation mode overview are shown below.

(a) Rotary switch setting and operation mode

Mitsubishi Electronics Q172DCPU — (1) Operation mode diagram (page 103)
Fig. 78 · (1) Operation mode

(Note-1) : Do not set except the above setting. (Note-2) : The programs, parameters, absolute position data, and latch data in the

SRAM built-in Motion CPU module are cleared.

1)

Page 104 of the Mitsubishi Electronics Q172DCPU user manual — 4 AUXILIARY AND APPLIED FUNCTIONS
Page 104 · click to enlarge
Page 104

4 AUXILIARY AND APPLIED FUNCTIONS

(b) Operation mode overview

Operation mode 7-segment LED Operation overview

  • " . " remains flashing in the first digit of 7-segment LED.
  • It operates based on the user programs and parameters stored in the SRAM

built-in Motion CPU module.

  • The user programs and parameters for the ROM operation can be written to

the FLASH ROM built-in Motion CPU module.

  • " . " remains flashing in the first digit and steady " . " display in the second

digit of 7-segment LED.

  • Operation starts after the user programs and parameters stored in the FLASH

ROM built-in Motion CPU module are read to the SRAM built-in Motion CPU

module at power supply on or reset of the Multiple CPU system.

If the ROM writing is not executed, even if the user programs and parameters

are changed using the MT Developer during mode operated by ROM,

operation starts with the contents of the FLASH ROM at next power supply on

or reset.

Also, If the ROM writing is not executed, even if the auto tuning data are

reflected on the servo parameter of Motion CPU by operation in the auto-tuning

setting, operation starts with the contents of the FLASH ROM at next power

supply on or reset.

POINT Do not change the rotary switch setting during operation. Be sure to turn OFF the power supply before the rotary switch setting change.

Show 4 more labels / short text on this page
Mode operated · by RAM · Mode operated · by ROM
Page 105 of the Mitsubishi Electronics Q172DCPU user manual — SV13 SV22
Page 105 · click to enlarge
Page 105

4 AUXILIARY AND APPLIED FUNCTIONS

4.4.2 Outline of ROM operation

When the ROM writing is requested to the Motion CPU module using the MT Developer, the programs and parameters stored in the SRAM built-in Motion CPU module are batch-written to the FLASH ROM, after the data of FLASH ROM built-in Motion CPU are erased. When the Motion CPU starts in the "Mode operated by ROM", a normal operation starts, after the data written in the FLASH ROM is read to the SRAM.

  • The programs and parameters created by the MT Developer must be written beforehand to the FLASH ROM built-in Motion CPU module at the ROM operation. The following methods for ROM writing are shown below.
  • Write the programs and parameters written in the SRAM built-in Motion CPU module to the FLASH ROM built-in Motion CPU module.
  • Write the programs and parameters of the MT Developer to the SRAM built-in Motion CPU module, and then write them to the FLASH ROM built-in Motion CPU module.

The data batch written to the FLASH ROM built-in Motion CPU module by ROM writing are shown below. Backup data except the followings (current position of servomotor in absolute position system, home position and latch device.) cannot be written to the FLASH ROM.

SV13 SV22

Each parameter for servo control

— Mechanical system program

POINT (1) "Backup • load" operation of the MT Developer targets the SRAM built-in

Motion CPU module. (The FLASH ROM built-in Motion CPU module is not targeted.) Set to "Mode operated by ROM" after ROM writing to execute the ROM operation after "Backup • load" operation at the Motion CPU module exchange. (2) The FLASH ROM built-in Motion CPU module serves as a life in 100000 times

writing. Make the ROM writing within 100000 times. If it passes over a life, "writing error" will occur, replace the Motion CPU module. (3) The online change of Motion SFC program executes the Motion SFC program

performed the online change from the next scanning at the mode operated by ROM. Operation starts with the contents of the Motion SFC program written in the FLASH ROM built-in Motion CPU module at next power supply on or reset. (4) It needs to meet the following conditions for the ROM writing.

(a) PLC ready flag (M2000) OFF (b) Not installation mode

Show 5 more labels / short text on this page
System setting data · Servo program · Motion SFC parameter · Motion SFC program · — Cam data
Page 106 of the Mitsubishi Electronics Q172DCPU user manual — FLASH ROM
Page 106 · click to enlarge
Page 106

4 AUXILIARY AND APPLIED FUNCTIONS

(1) Write the programs and parameters written in the SRAM built-in Motion CPU

module to the FLASH ROM built-in Motion CPU module for the ROM operation.

Mode operated by RAM/Mode operated by ROM

Be sure to write the programs and parameters beforehand to the SRAM built-in Motion CPU module at the ROM operation.

SRAM

IBM PC/AT

Programs Parameters, etc.

1. ROM writing request Programs Parameters, etc.

FLASH ROM

Programs Parameters, etc.

2. ROM writing

Mode operated by RAM/Mode operated by ROM

SRAM

Programs Parameters, etc.

FLASH ROM

Programs Parameters, etc.

Show 6 more labels / short text on this page
<ROM writing> · Motion CPU module · MT Developer · <ROM operation> · Motion CPU module · Read at starting
Page 107 of the Mitsubishi Electronics Q172DCPU user manual — POINT
Page 107 · click to enlarge
Page 107

4 AUXILIARY AND APPLIED FUNCTIONS

Write the data of SRAM built-in Motion CPU module to the ROM.

The operating procedure for ROM writing using the MT Developer is shown below.

Main Frame screen

Mitsubishi Electronics Q172DCPU — Main Frame screen diagram (page 107)
Fig. 79 · Main Frame screen
1. Select menu "Online" -"Export to ROM Format" to display "Export to ROM Format" screen.

Export to ROM Format screen

Mitsubishi Electronics Q172DCPU — Export to ROM Format screen diagram (page 107)
Fig. 80 · Export to ROM Format screen
2. Select "Execute" button. ROM writing is executed to FLASH ROM built-in Motion CPU module.

POINT

Be sure to write the all data beforehand to SRAM built-in Motion CPU module at the ROM writing.

Operating procedure

Page 108 of the Mitsubishi Electronics Q172DCPU user manual — FLASH ROM
Page 108 · click to enlarge
Page 108

4 AUXILIARY AND APPLIED FUNCTIONS

(2) Write the programs and parameters of the MT Developer to the SRAM built-in

Motion CPU module, and then write them to the FLASH ROM built-in Motion CPU module for the ROM operation.

Mode operated by RAM/Mode operated by ROM

IBM PC/AT

SRAM

1. Write data (ROM writing request)

Programs Parameters, etc.

Programs Parameters, etc.

2. ROM writing request after write data

FLASH ROM

Programs Parameters, etc.

3. ROM writing

Mode operated by RAM/Mode operated by ROM

SRAM

Programs Parameters, etc.

FLASH ROM

Programs Parameters, etc.

Show 5 more labels / short text on this page
Motion CPU module · MT Developer · <ROM operation> · Motion CPU module · Read at starting
Page 109 of the Mitsubishi Electronics Q172DCPU user manual — POINT
Page 109 · click to enlarge
Page 109

4 AUXILIARY AND APPLIED FUNCTIONS

Write the data of MT Developer to the ROM.

The operating procedure for ROM writing using the MT Developer is shown below.

Main Frame screen

Mitsubishi Electronics Q172DCPU — Main Frame screen diagram (page 109)
Fig. 81 · Main Frame screen
1. Select menu "Online" -"Write to CPU" to display "Write to CPU" screen.

Write to CPU screen

Mitsubishi Electronics Q172DCPU — Write to CPU screen diagram (page 109)
Fig. 82 · Write to CPU screen
2. Check data of MT Developer written in the Motion CPU.
3. Select "Program memory + CPU ROM" in target memory.
4. Select "Execute" button. SRAM data built in Motion CPU module is written to ROM after writing data of MT developer to SRAM built-in Motion CPU module.

(Note): Mechanical system program and cam data (converted data) cannot be displayed when using OS type "SW8DNC-SV13".

POINT

Be sure to write the all data beforehand to SRAM built-in Motion CPU module at the ROM writing.

Operating procedure

Page 110 of the Mitsubishi Electronics Q172DCPU user manual — YES
Page 110 · click to enlarge
Page 110

4 AUXILIARY AND APPLIED FUNCTIONS

4.4.3 Operating procedure of the ROM operation function

The outline procedure of ROM operation function is shown below. 1) Turn on or reset the power supply of Multiple CPU system in the "Mode operated by RAM". 2) Create the system setting, programs and parameters using the MT Developer, and execute a trial run and adjustment. 3) Write the system setting, programs and parameters of SRAM built-in Motion CPU module to the FLASH ROM built-in Motion CPU module by the ROM writing request using the MT Developer. 4) By starting the Motion CPU in the "Mode operated by ROM", a normal operation starts after the system setting, programs and parameters written in the FLASH ROM built-in Motion CPU module are read to the SRAM built-in Motion CPU module.

(1) ROM operation procedure

The ROM operation procedure is shown below.

Preparation for ROM operation

Set the "Mode operated by RAM" by setting the rotary switch 1 (SW1) and 2 (SW2) to "0".

Turn ON the power supply of Multiple CPU system.

Create or correct the system setting, parameters and programs using the MT Developer, and write them to the Motion CPU module.

Execute the trial run and adjustment.

NO

Is the operation normal ?

YES

Mode operated by RAM (ROM writing)

Execute the "ROM writing" of the programs and parameters in a lump using the MT Developer.

Turn OFF the power supply of Multiple CPU system.

Set the "Mode operated by ROM" by setting the rotary switch 1 (SW1) to "0" and rotary switch 2 (SW2) to "6".

Turn ON the power supply of Multiple CPU system.

Mode operated by ROM

ROM operation start

Page 111 of the Mitsubishi Electronics Q172DCPU user manual — YES
Page 111 · click to enlarge
Page 111

4 AUXILIARY AND APPLIED FUNCTIONS

(2) Operation at the "Mode operated by ROM"

Mode operated by ROM start

(Data (programs, parameters and absolute position data) is not written to the FLASH ROM built-in Motion CPU module.)

Is the data write to the FLASH ROM built-in

NO

Motion CPU module ?

YES

Read the followings of the FLASH ROM built-in Motion CPU module to the SRAM built-in Motion CPU module. System setting data Parameter for servo control Servo program Motion SFC parameter Motion SFC program Mechanical system program (SV22) Cam data (SV22)

The system setting error (" AL" flashes 3 times steady "L01" display) in the 7- segment LED at the front side of Motion CPU module.

Wait the restart of Multiple CPU system.

After that, it cannot be operated because of stop state. Retry the operation for "ROM writing" "Mode operated by ROM" after confirm the contents for programs and parameters of the SRAM built-in Motion CPU module.

After that, it is same operation at the RAM operation.

POINT (1) Change the operation mode using the rotary switch of Motion CPU module. (2) Confirm the operation mode by the 7-segment LED of Motion CPU module.

Normal operation start

Page 112 of the Mitsubishi Electronics Q172DCPU user manual — (2) Procedure for password change
Page 112 · click to enlarge
Page 112

4 AUXILIARY AND APPLIED FUNCTIONS

4.5 Security Function

This function is used to protect the user data of Motion CPU by registering a password. The illegal reading or writing of the user data are prevented by setting a password. Registered password can be changed and deleted. [Register/Change Password] or [Delete Password] screen is used to register/ change/delete a password. Select from a menu bar to display these screen.

Mitsubishi Electronics Q172DCPU — 4 AUXILIARY AND APPLIED FUNCTIONS diagram (page 112)
Fig. 83

The user data protected in this function are shown below. "Write Protection" or "Read/Write Protection" can be set every user data.

system software User data Protected contents

Motion SFC program Motion SFC programs (Control code, text) SV13/SV22

Servo program Servo programs and program allocation

Mechanical system program Mechanical system programs SV22

Cam data Cam data

4.5.1 Password registration/change

Select menu [Online] [Register Password] [Register/Change] to register/change a password.

(1) Procedure for password registration

(a) Enter initial registration password in password column, and select

registration condition (Write Protection, Read/Write Protection). It leaves in blank for the user data that does not register a password.

(b) Click on [Execute] button to register a password in the Motion CPU.

(c) Select menu [Project] [Save] to save a password after registration in a project. Refer to Section 4.5.4 for password save.

(2) Procedure for password change

(a) Status of password registered in the Motion CPU are displayed.

Operating

Page 113 of the Mitsubishi Electronics Q172DCPU user manual — 4 AUXILIARY AND APPLIED FUNCTIONS
Page 113 · click to enlarge
Page 113

4 AUXILIARY AND APPLIED FUNCTIONS

(b) Enter new password in password column, and select registration condition

(Write Protection, Read/Write Protection). It leaves in blank for the user data that does not change a password.

(c) Click on [Execute] button to display [Check Password] screen for old

password confirmation. Click on [Execute] button after old password input. New password will be registered in the Motion CPU by success of old password check. When the new password is the same as old password (change for only registration condition), [Check Password] screen is not displayed.

(d) Select menu [Project] [Save] to save a password after change in a project. Refer to Section 4.5.4 for password save.

POINT (1) If an user has forgotten a registration password, clear a password of Motion

CPU by the all clear function. However, the all password data and user data are cleared by the all clear function. Re-write the user data to the Motion CPU. (Refer to Section 4.6 for details.) (2) ROM operation can be executed by user data registered a password.

The password setting is also included in the ROM writing/reading data. (3) The password data is not save in a project without password save.

Therefore, be sure to save a password. (4) If an operation stops by reset or power OFF of the Multiple CPU system while

a password registration/change, the user data may not be registered. Register/change a password again to restore the user data.

Mitsubishi Electronics Q172DCPU — 4 AUXILIARY AND APPLIED FUNCTIONS diagram (page 113)
Fig. 84

Type Type of user data

Registration " " is displayed when a password is registered in the Motion CPU.

Enter initial registration/change password.

Alphanumeric character (ASCII) of 6 or less

Match case (Not full-size character)

A registration condition set in the Motion CPU is displayed.

  • Write Protection
  • Read/Write Protection

New registration condition can be selected by password input.

Items Details · Password · Registration condition

Page 114 of the Mitsubishi Electronics Q172DCPU user manual — (1) Procedure for password delete
Page 114 · click to enlarge
Page 114

4 AUXILIARY AND APPLIED FUNCTIONS

4.5.2 Password delete

Select menu [Online] [Register Password] [Delete] to delete a password.

(1) Procedure for password delete

(a) Status of password registered in the Motion CPU are displayed.

(b) Enter old password and click on [Execute] button to delete password. It

leaves in blank for the user data that does not delete a password.

(c) A password will be deleted by success of password check. (" " displayed in registration column disappears.)

(d) Select menu [Project] [Save] to save a password after delete in a project. Refer to Section 4.5.4 for password save.

POINT (1) The password data is not save in a project without password save.

Therefore, be sure to save a password.

(2) If an operation stops by reset or power OFF of the Multiple CPU system while

delete of password, the data may not be deleted. Delete a password again to restore the user data.

Mitsubishi Electronics Q172DCPU — (1) Procedure for password delete diagram (page 114)
Fig. 85 · (1) Procedure for password delete

Type Type of user data

Registration " " is displayed when a password is registered in the Motion CPU.

Password Enter old password.

Items Details

Page 115 of the Mitsubishi Electronics Q172DCPU user manual — (1) Procedure for password check
Page 115 · click to enlarge
Page 115

4 AUXILIARY AND APPLIED FUNCTIONS

4.5.3 Password check

When operating the user data that sets password, the check password screen is displayed automatically.

(1) Procedure for password check

(a) Enter old password in password column, and click on [Execute] button.

(b) Protection by the password temporarily released by success of password

check. After that it can be operated the user data.

(c) A password is memorized until MT Developer ends. (Since protection by

password is automatically released temporarily at the user data operation, a check password screen is not displayed.)

Mitsubishi Electronics Q172DCPU — (1) Procedure for password check diagram (page 115)
Fig. 86 · (1) Procedure for password check

Type Type of user data

Password Enter old password.

Items Details

Page 116 of the Mitsubishi Electronics Q172DCPU user manual — (1) Status of password data for each operation
Page 116 · click to enlarge
Page 116

4 AUXILIARY AND APPLIED FUNCTIONS

4.5.4 Password save

Registered/changed/deleted password or password read with user data from "Read from CPU" screen displayed by menu [Online] [Read from CPU] can be saved in a project data. A password saved in a project data can be registered with user data, when the user data are written in the Motion CPU that does not set password from "Write to CPU" screen displayed by menu [Online] [Write to CPU].

Select menu [Project] [Save] to save the updated password data in a project.

(1) Status of password data for each operation

Operation Status of password data

Read When a password is set in the call source Motion CPU, the password contents are called and the password data in a project are updated.

Write When a password data is set in a project, if a password is not set in the write designation Motion CPU, the password contents are also written.

Verification Password data in a project are not updated.

ROM writing Password contents registered in the write designation Motion CPU are written in ROM.

Online change Password contents of write designation Motion CPU are not updated.

Backup It is saved in backup data including also the password contents registered in the call source Motion CPU. The password data in a project is not updated.

Load Password contents in backup data are written in the write designation Motion CPU.

New password contents are written in the write designation Motion CPU. Password data in a project is also updated to new password contents.

Delete password A password is deleted from the write designation Motion CPU. A password is deleted also from the password data in a project.

Project diversion The password data in diverting source project is not diverted.

POINT (1) The password data is not save in a project without project save. (2) Save a project after delete of password to delete the password data in a

project. Or, create a project without password data by creating new project and diverting user data from a project with password data.

Register/change password

Page 117 of the Mitsubishi Electronics Q172DCPU user manual — 4 AUXILIARY AND APPLIED FUNCTIONS
Page 117 · click to enlarge
Page 117

4 AUXILIARY AND APPLIED FUNCTIONS

4.6 All clear function

This function is used to clear the all user data, password setting, backup area and user data area of FLASH ROM in the Motion CPU module. (1) Procedure for clear all

(a) Set the Motion CPU module to installation mode (Set a rotary switch 1

(SW1) to "A".)

(b) Select [Execute] button of "Clear CPU Memory" screen displayed by menu

[Online] [Clear CPU Memory]".

Mitsubishi Electronics Q172DCPU — 4 AUXILIARY AND APPLIED FUNCTIONS diagram (page 117)
Fig. 87

POINT (1) Set the Motion CPU module to installation mode to clear all.

Be sure to set a rotary switch after power supply OFF. (2) The user data area of FLASH ROM built-in Motion CPU module is also

cleared. (3) All user data and password setting are cleared at the "Clear all".

It is recommended to be backup them in advance using MT Developer.

Page 118 of the Mitsubishi Electronics Q172DCPU user manual — 4 AUXILIARY AND APPLIED FUNCTIONS
Page 118 · click to enlarge
Page 118

4 AUXILIARY AND APPLIED FUNCTIONS

4.7 Communication via Network

The communication between the personal computer and the Motion CPU is possible via Q series Network module (MELSECNET/10(H), Ethernet, CC-Link and etc.) in the Motion CPU (Q173DCPU/Q172DCPU). Refer to the PLC manuals for the specifications of each network modules of MELSECNET/10(H), Ethernet, CC-Link and Serial communication, the handling method. 4.7.1 Specifications of the communications via network

(1) Communications via network enables using MT Developer in the Motion CPU.

(2) Access range of the communications via network of the Motion CPU is an access

range equivalent to QnUD(H)CPU. (Refer to Section "4.7.2 Access range of the communications via network".)

(3) By setting the routing parameter to the control CPU of the network module and the

CPU which connected the peripheral devices in the network by MELSECNET/10(H) and Ethernet, it is possible to relay to 8 network points and communicate.

(4) Because the Motion CPU cannot become the control CPU of the network module,

there is not setting item of the network module and network parameter. However, when connecting with the CPU on the other network from the peripheral device which connected the Motion CPU, it needs to the setting of the routing parameter.

(5) It can operate by remote control the monitor or program editing of the Motion CPU

via the intranet using the Ethernet module.

Mitsubishi Electronics Q172DCPU — 4 AUXILIARY AND APPLIED FUNCTIONS diagram (page 118)
Fig. 88

Personal Computer · Personal Computer

Page 119 of the Mitsubishi Electronics Q172DCPU user manual — <Example>
Page 119 · click to enlarge
Page 119

4 AUXILIARY AND APPLIED FUNCTIONS

4.7.2 Access range of the communications via network

(1) Network configuration via the MELSECNET/10(H) or the Ethernet

(a) It can access the other CPU via the network from the programming software

packages (GX Developer, MT Developer, etc.) of the personal computer connected with the CPU or serial communication module in USB/RS-232.

(b) It can access the other CPU via the network from the programming software

packages in the personal computer by connecting the personal computer equipped with Ethernet to MELSECNET/10(H) or Ethernet board to the Ethernet to MELSECNET/10(H) or Ethernet.

(c) The access range of above (1) and (2) can be accessed to 8 network points

by setting the routing parameter to the control CPU of the network module and the CPU which connected the personal computer.

<Example>

Mitsubishi Electronics Q172DCPU — <Example> diagram (page 119)
Fig. 89 · <Example>

Network No.2

Network No.6

Network No.10

: Communication is possible : Communication is possible (Setting of the routing parameter is necessary.) : Communication is impossible

Page 120 of the Mitsubishi Electronics Q172DCPU user manual — <Example 2>
Page 120 · click to enlarge
Page 120

4 AUXILIARY AND APPLIED FUNCTIONS

(2) Network configuration via the CC-Link

(a) It can access the other CPU via the CC-link from the programming software

packages (GX Developer, MT Developer, etc.) of the personal computer connected with the CPU or serial communication module in USB/RS-232.

(b) It can access the other CPU via the CC-Link from the programming software

packages in the personal computer by connecting the personal computer equipped with CC-Link board to the CC-Link.

(c) The access range of above (1) is only the CPU on the CC-Link which a

system connects it to, and it can select a CC-Link network to connect by specifying the I/O No. of the CC-Link module.

(d) The access range of above (2) is only the CPU of the connected the CC-

Link.

Mitsubishi Electronics Q172DCPU — 4 AUXILIARY AND APPLIED FUNCTIONS diagram (page 120)
Fig. 90

Network No.2

<Example 2>

Mitsubishi Electronics Q172DCPU — <Example 2> diagram (page 120)
Fig. 91 · <Example 2>

Network No.2

Page 121 of the Mitsubishi Electronics Q172DCPU user manual — RS-422/485
Page 121 · click to enlarge
Page 121

4 AUXILIARY AND APPLIED FUNCTIONS

(3) Network configuration via the RS-422/485

(a) It can access the other CPU via the RS-422/485 from the programming

software packages (GX Developer, MT Developer, etc.) of the personal computer connected with the CPU or serial communication module in USB/RS-232.

(b) The access range of above (1) is only the CPU on the RS-422/485 which a

system connects it to, and it can select RS-422/485 network to connect by specifying the I/O No. of the C24 module.

Mitsubishi Electronics Q172DCPU — 4 AUXILIARY AND APPLIED FUNCTIONS diagram (page 121)
Fig. 92

RS-422/485

<Example 2>

Mitsubishi Electronics Q172DCPU — RS-422/485 diagram (page 121)
Fig. 93

RS-422/485

Q173D CPU QnUD(H) CPU Q173D CPU QnUD(H) CPU Q173D CPU QnUD(H) CPU

Page 122 of the Mitsubishi Electronics Q172DCPU user manual — <Example 1>
Page 122 · click to enlarge
Page 122

4 AUXILIARY AND APPLIED FUNCTIONS

(4) Network configuration which MELSECNET/10(H), Ethernet, CC-

Link, RS-422/485 were mixed (a) When the MELSECNET/10(H) or Ethernet is defined as "Network" and CC-

Link or RS-422/485 is defined as "Link", combination of whether to be able to access from the programming software packages (GX Developer, MT Developer, etc.) is shown below.

Mitsubishi Electronics Q172DCPU — 4 AUXILIARY AND APPLIED FUNCTIONS diagram (page 122)
Fig. 94

Programming software package CPU (C24) Network Link CPU Programming software package CPU (C24) Link Network CPU Programming software package Network Link CPU Programming software package Link Network CPU Programming software package CPU (C24) Network Link Network CPU Programming software package CPU (C24) Link Network Link CPU Programming software package Network Link Network CPU Programming software package Link Network Link CPU

: Usable : Unusable

(b) It can be accessed to 8 network points by setting the routing parameter in

the "Network".

(c) Because routing cannot access, it can access only the connected network.

The connected network can be selected by specifying the I/O No. of the module.

<Example 1>

Mitsubishi Electronics Q172DCPU — <Example 1> diagram (page 122)
Fig. 95 · <Example 1>

: Communication is possible : Communication is possible (Setting of the routing parameter is necessary.) : Communication is impossible

Page 123 of the Mitsubishi Electronics Q172DCPU user manual — <Example 3>
Page 123 · click to enlarge
Page 123

4 AUXILIARY AND APPLIED FUNCTIONS

<Example 2>

Mitsubishi Electronics Q172DCPU — <Example 2> diagram (page 123)
Fig. 96 · <Example 2>

Network No.1

<Example 3>

Mitsubishi Electronics Q172DCPU — <Example 3> diagram (page 123)
Fig. 97 · <Example 3>

Network No.1

: Communication is possible : Communication is possible (Setting of the routing parameter is necessary.) : Communication is impossible

Page 124 of the Mitsubishi Electronics Q172DCPU user manual — 4 AUXILIARY AND APPLIED FUNCTIONS
Page 124 · click to enlarge
Page 124

4 AUXILIARY AND APPLIED FUNCTIONS

4.8 Monitor Function of the Main Cycle

(1) Information for main cycle of the Motion CPU (process cycle executed at free time

except for motion control) is stored to the special register.

(2) Since the automatic refresh of CPU shared memory and normal task of Motion

SFC program are executed in the main cycle, make it reference for process time, etc. to program.

(3) There are following methods to shorten a main cycle.

(a) Lengthen an operation cycle setting. (b) Reduce the number of event task programs to execute in the Motion SFC

program. (c) Reduce the number of normal task programs to execute simultaneously in

the Motion SFC program. (d) Reduce the number of automatic refresh points of CPU shared memory.

(4) When a main cycle is lengthened (more than 1.0[s]), a WDT error may occur in

the Motion CPU.

(5) Details of main cycle monitor register is shown below.

No. Name Meaning Details

SD520 Scan time Current scan time (1ms units)

  • Current scan time is stored in the unit 1[ms].
  • Setting range (0 to 65535[ms])

SD521 Maximum scan time Maximum scan time (1ms units)

  • Maximum main cycle is stored in the unit 1[ms].
  • Setting range (0 to 65535[ms])
Page 125 of the Mitsubishi Electronics Q172DCPU user manual — 4 AUXILIARY AND APPLIED FUNCTIONS
Page 125 · click to enlarge
Page 125

4 AUXILIARY AND APPLIED FUNCTIONS

4.9 Servo Parameter Reading Function

(1) When the servo parameters are changed, the Motion CPU will be automatically

read the servo parameters and reflected them to the servo parameter storage area in the Motion CPU. Therefore, an operation to read servo parameters is unnecessary in the following cases.

(a) The parameters are changed by auto tuning. (b) The parameters are changed by connecting directly MR Configurator to the

servo amplifier.

POINT If the power supply of Multiple CPU system is turned off/reset or the power supply of servo amplifier is turned off immediately after change, it may not be reflected.

(2) After executing the servo parameter reading function, when it needs to reflect the

servo parameters changed to the MT Developer, read the servo parameters from the Motion CPU and save data.

Page 126 of the Mitsubishi Electronics Q172DCPU user manual — (2) Devices that can be set
Page 126 · click to enlarge
Page 126

4 AUXILIARY AND APPLIED FUNCTIONS

4.10 Optional Data Monitor Function

This function is used to store the data (refer to following table) up to three points per axis to the specified devices (D, W, #, U \G) and monitor them. It can be set by the system setting of MT Developer. (1) Data that can be set

Mitsubishi Electronics Q172DCPU — 4 AUXILIARY AND APPLIED FUNCTIONS diagram (page 126)
Fig. 98

(2) Devices that can be set

Mitsubishi Electronics Q172DCPU — (2) Devices that can be set diagram (page 126)
Fig. 99 · (2) Devices that can be set

(Note-1): "p" indicates the user setting area points of the Multiple CPU high speed transmission area

for the each CPU. (Note-2): Only device of the self CPU can be used.

Mitsubishi Electronics Q172DCPU — (2) Devices that can be set diagram (page 126)
Fig. 100 · (2) Devices that can be set

POINT (1) The updating cycle of data is every operation cycle. (2) Set an even number as device setting in the two word data. (3) Refer to Chapter 2 for the user setting area points of the Multiple CPU high

Page 127 of the Mitsubishi Electronics Q172DCPU user manual — (2) Connect/disconnect command devices
Page 127 · click to enlarge
Page 127

4 AUXILIARY AND APPLIED FUNCTIONS

4.11 Connect/Disconnect Function

This function is used to temporarily suspend SSCNET communication while servo amplifiers and/or SSCNET cables after Axis 1 are exchanged with the power supply ON in a Multiple CPU system. SD803 is required for connect/disconnect and SD508 stores the command status for "accept waiting" or "execute waiting" during this process. If a servo amplifier was previously removed using the connect/disconnect function, it must be used again to reconnect the servo amplifier. This function is only required when there is a desire to maintain communication to all axes in front of the one being removed. No connect/disconnect processing is required if the power supply to Axis 1 is shutdown.

(1) Connect/disconnect status devices

Mitsubishi Electronics Q172DCPU — (1) Connect/disconnect status devices diagram (page 127)
Fig. 101 · (1) Connect/disconnect status devices

Connect command or disconnect command is in the status that can be accepted

SD508 is waiting for connect/disconnect execute command after accepting a connect command or disconnect command.

(2) Connect/disconnect command devices

Mitsubishi Electronics Q172DCPU — (2) Connect/disconnect command devices diagram (page 127)
Fig. 102 · (2) Connect/disconnect command devices

0 None This value is set if there is no command.

1 to 32 Disconnect command Set axis No. "1 to 32" to be disconnected.

-10 Connect command Set to connect axis while disconnecting.

Connect/disconnect processing is executed by setting this value in the status of a connect/disconnect execute waiting.

Page 128 of the Mitsubishi Electronics Q172DCPU user manual — 4 AUXILIARY AND APPLIED FUNCTIONS
Page 128 · click to enlarge
Page 128

4 AUXILIARY AND APPLIED FUNCTIONS

POINT (1) After completion of SSCNET communication disconnect processing, be sure to

check the LED display of the servo amplifier for "AA" before turning OFF its the power supply. (2) When a "1 to 32 : Disconnect command" and/or "-10 : Connect command"

are set to the "Connect/disconnect command device (SD803)", the status of the SD508 changes to the "-1: Connect/disconnect waiting" state. In order to complete connect/disconnect processing, "-2 : Connect/disconnect execute command" must be set to SD803 to execute the prior connect/disconnect command. (3) When "1 to 32 : Disconnect command" is set to axis not disconnect, the

connect/disconnect status device (SD508) returns "0" without entering the status of "-1 : Connect/disconnect execute waiting". (4) Operation failure may occur in some axes if the power supply of servo

amplifiers connected after them on the SSCNET system is turned OFF. Be sure to use the disconnect function before turning OFF the power supply of any servo amplifiers connected after an amplifier whose power remains on.

(3) Procedure for connect/disconnect function to exchange the servo amplifier or

SSCNET cable is shown below.

(a) Operation procedure to disconnect

1. Set the axis No. to disconnect in SD803. (Setting value: 1 to 32)
2. Check that "-1: Disconnect execute waiting" is set in SD508. (Disconnect execute waiting)
3. Set "-2: Disconnect execute command" in SD803.
4. Check that "0: Disconnect command accept waiting" is set in SD508. (Completion of disconnection)
5. Turn OFF the power supply of servo amplifier after checking its LED display for "AA" and then disconnect.
Page 129 of the Mitsubishi Electronics Q172DCPU user manual — SD803
Page 129 · click to enlarge
Page 129

4 AUXILIARY AND APPLIED FUNCTIONS

(b) Operation procedure to connect

1. Turn ON the power supply of the servo amplifier.
2. Set "-10: Connect command" in SD803.
3. Check that "-1: Connect execute waiting" is set in SD508. (Connect execute waiting)
4. Set "-2: Connect execute command" in SD803.
5. Check that SD508 is "0: Connect command accept waiting" is set in SD508. (Completion of connection)
6. Resume operation of servo amplifier after verifying the servo ready status (M2415+20n) is ON.

(4) Flow for device value at connect/disconnect operation is shown below.

Disconnect command (Axis No. of servo amplifier to disconnect)

Mitsubishi Electronics Q172DCPU — 4 AUXILIARY AND APPLIED FUNCTIONS diagram (page 129)
Fig. 103

SD803

Mitsubishi Electronics Q172DCPU — SD803 diagram (page 129)
Fig. 104

SD803

Show 9 more labels / short text on this page
(a) Disconnect operation · Disconnect execute command · Disconnect command clear · Monitor · (b) Connect operation · Connect command · Connect execute command · Connect command clear · Monitor
Page 130 of the Mitsubishi Electronics Q172DCPU user manual — 4 AUXILIARY AND APPLIED FUNCTIONS
Page 130 · click to enlarge
Page 130

4 AUXILIARY AND APPLIED FUNCTIONS

(1) Self CPU program which connects/disconnects servo amplifiers from Axis 5 on

Disconnect procedureTurn OFF the power supply of servo amplifier after

checking its LED display for "AA". Connect procedure: Resume operation of servo amplifier after verifying

that the servo ready (M2415+20n) is ON.

Mitsubishi Electronics Q172DCPU — 4 AUXILIARY AND APPLIED FUNCTIONS diagram (page 130)
Fig. 105

Set "5" (Disconnect from Axis 5 on) as disconnect command in SD803.

Page 131 of the Mitsubishi Electronics Q172DCPU user manual — D100 K0 = M10 M11
Page 131 · click to enlarge
Page 131

4 AUXILIARY AND APPLIED FUNCTIONS

(2) PLC CPU program which connects/disconnects servo amplifiers from Axis 5 on

which is connected to the Motion CPU (CPU No.2).

Disconnect procedureTurn X0 OFF to ON, and then turn OFF the power

supply of servo amplifier after checking the LED display "AA" of servo amplifier. Connect procedure: Turn X1 OFF to ON, and then resume operation of

servo amplifier after checking the servo ready (M2415+20n) of servo amplifier.

Q172D CPU

QY40 QY40 Q172D LX

QY40

Disconnection (From Axis 5 on)

AMP

AMP

AMP

AMP

AMP

AMP

M

M

M

M

M

M

0 SM400

K1 D51 MOV

Set "-2" as disconnect execute command in D104.

K-2 D104 MOV

5 M101 M100 M102 X0

K5 D102 MOV

Set "5" (Disconnect afrom Axis 5 on) as disconnect command in D102.

M100 SET

Set "-10" as connect command in D102.

K-10 D102 MOV

M100 SET

M10 M100

DP.DDRD H3E1 D100 M10 SD508 D50

Read the data of SD508 for Multiple CPU system (CPU No.2) by turning M100 ON, and store it to data area (D100) of self CPU.

D100 K0 = M10 M11

M100 RST

SET

M101

M12 M101

DP.DDWR H3E1 SD803 M12 D102 D50

Write the data of SD803 for Multiple CPU system (CPU No.2) to D102 by turning M101 ON. (Disconnect command/Connect command)

M12 M13

M101 RST

M102 SET

M10 M102

DP.DDRD H3E1 D100 M10 SD508 D50 57

Read the data of SD508 for Multiple CPU system (CPU No.2) by turning M102 ON, and store it to data area (D100) of self CPU.

D100 K-1 = M10 M11

M102 RST

M103 SET

M12 M103

DP.DDWR H3E1 SD803 M12 D104 D50

Write the data of SD803 for Multiple CPU system (CPU No.2) to D104 by turning M103 ON. (Disconnect execute command)

M12 M13

M103 RST

M104 SET

M10 M104

DP.DDRD H3E1 D100 M10 SD508 D50 96

Read the data of SD508 for Multiple CPU system (CPU No.2) by turning M104 ON, and store it to data area (D100) of self CPU.

D100 K0 = M10 M11

M104 RST

Show 9 more labels / short text on this page
System configuration · Q61P QnUD(H) CPU · Axis 1 · Axis 2 · Axis 3 · Axis 4 · Axis 5 · Axis 8 · PLC program
Page 132 of the Mitsubishi Electronics Q172DCPU user manual — (1) Operation procedure
Page 132 · click to enlarge
Page 132

4 AUXILIARY AND APPLIED FUNCTIONS

4.12 Remote operation

  • This function is used to control the following operation of Motion CPU using MT Developer.
  • Remote RUN/STOP
  • Remote latch clear

POINT Latch clear can be executed only using the remote control of MT Developer. 4.12.1 Remote RUN/STOP

The PLC ready flag (M2000) is turned ON/OFF by MT Developer with RUN/STOP switch of Motion CPU module set to RUN.

(1) Operation procedure

Select [RUN] on "CPU remote operation" screen displayed by menu [Online] – [Remote Operation], and click [Execute] button.

Select [STOP] on "CPU remote operation" screen displayed by menu [Online] – [Remote Operation], and click [Execute] button.

Mitsubishi Electronics Q172DCPU — (1) Operation procedure diagram (page 132)
Fig. 106 · (1) Operation procedure

(a) Remote RUN · (b) Remote STOP

Page 133 of the Mitsubishi Electronics Q172DCPU user manual — REMARK
Page 133 · click to enlarge
Page 133

4 AUXILIARY AND APPLIED FUNCTIONS

POINT (1) Remote RUN cannot be executed if RUN/STOP switch sets to STOP.

Operation after remote operation by RUN/STOP switch is shown below.

Position of RUN/STOP switch RUN STOP

Execute remote RUN RUN STOP

Execute remote STOP STOP STOP

(2) The following parameters are read by turning on the PLC ready flag (M2000).

  • Fixed parameter
  • Parameter block
  • Home position return data
  • JOG operation data
  • Servo parameter
  • Mechanical system program (SV22)
  • Motion SFC parameter
  • Limit switch parameter

REMARK

The PLC ready flag (M2000) can also be turned ON/OFF (PCPU READY complete flag (SM500) ON/OFF) in the following methods.

  • RUN/STOP switch change
  • PLC ready flag (M2000) ON/OFF

Remote operation

Page 134 of the Mitsubishi Electronics Q172DCPU user manual — (1) Operation procedure
Page 134 · click to enlarge
Page 134

4 AUXILIARY AND APPLIED FUNCTIONS

4.12.2 Remote latch clear

Device data of Motion CPU that latched are cleared by MT Developer at PLC ready flag (M2000) OFF (PCPU READY complete flag (SM500) OFF). Operation for remote latch clear is combined with remote RUN/STOP.

(1) Operation procedure

(a) Turn OFF the PLC ready flag (M2000) (PCPU READY complete flag

(SM500) OFF) by remote STOP.

(b) Select [Latch clear (1)] or [Latch clear (1)(2)] on "CPU remote operation"

screen displayed by menu [Online] – [Remote Operation], and click [Execute] button.

(Note)Execute remote RUN to turn ON the PLC ready flag (M2000) after

remote latch clear.

POINT (1) Remote latch clear cannot be operated while the PLC ready flag (M2000) is ON

(PCPU READY complete flag (SM500) is ON) or test mode. (2) The following latch area are cleared in the remote latch clear operation.

  • Latch clear (1) : Clear the range set in latch area (1)
  • Latch clear (1)(2) : Clear the range set in latch area (1) and (2) (3) The user area (#0 to #7999) of motion device are also cleared by executing remote

latch clear. (4) All of the user device not latched are cleared by the remote latch clear operation of

latch area (1) and (2). (5) Set the range of latch area (1) and (2) in the system basic setting of system setting.

(Refer to Section 3.1.3.)

Page 135 of the Mitsubishi Electronics Q172DCPU user manual — 4 AUXILIARY AND APPLIED FUNCTIONS
Page 135 · click to enlarge
Page 135

4 AUXILIARY AND APPLIED FUNCTIONS

MEMO

Page 136 of the Mitsubishi Electronics Q172DCPU user manual — APP - 1
Page 136 · click to enlarge
Page 136

APPENDICES

APPENDICES

APPENDIX 1 Special relays/Special registers

APPENDIX 1.1 Special relays

Special relays are internal relays whose applications are fixed in the Motion CPU. For this reason, they cannot be used in the same way as the normal internal relays by the Motion SFC programs. However, they can be turned ON/OFF as needed in order to control the Motion CPU.

The headings in the table that follows have the following meanings.

No. • Indicates the device No. of the special relay.

Name • Indicates the name of the special relay.

Meaning • Indicates the nature of the special relay.

Details • Indicates detailed information about the nature of the special relay.

  • Indicates whether the relay is set by the system or user, and, if it is set by system, when

setting is performed.

APP.

S: Set by system (Motion CPU)

U: Set by user (Motion SFC program or test operation using MT Developer)

S/USet by both system (Motion CPU) and user

Indicated only if setting is done by system (Motion CPU).

Main processSet during each main processing (free time processing of the CPU)
Initial processSet only during initial processing (when power supply is turned ON, or

when executed the reset)

Status changeSet only when there is a change in status

Error : Set when error is occurred.

RequestSet only when there is a user request (Special relay, etc.)

Operation cycle : Set during each operation cycle of the Motion CPU.

APP - 1

Show 4 more labels / short text on this page
Item Explanation · <Set by> · Set by · (When set)
Page 137 of the Mitsubishi Electronics Q172DCPU user manual — APP - 2
Page 137 · click to enlarge
Page 137

APPENDICES

Table 1.1 Special relay list

No. Name Meaning Details Set by (When set) Remark

  • Turn ON if an error occurs as a result of diagnosis.
  • Remains ON even if the condition is restored to normal thereafter.
  • Turn ON by ON to OFF of the Motion error detection flag (M2039) for except the stop error after confirming the error content.
SM0 Diagnostic error OFFNo error ON : Error
  • Turn ON if an error occurs as a result of self-diagnosis.
  • Remains ON even if the condition is restored to normal thereafter.
  • Turn ON by ON to OFF of the Motion error detection flag (M2039) for except the stop error after confirming the error content.
SM1 Self-diagnostic error OFFNo self-diagnostic error ON : Self-diagnostic error
  • Turn ON if the voltage of external battery reduces to less than 2.5[V].
  • Remains ON even if the condition is restored to normal thereafter.
SM51 Battery low latch OFFNormal ON : Battery low
  • Turn on when the voltage of the external battery reduces to less than 2.5[V].
  • Turn OFF when the voltage of external battery returns to normal.
SM52 Battery low OFFNormal ON : Battery low

S (Occur an error)

  • Turn ON if an instantaneous power failure of within 20[ms] occurs during use of the AC power supply module. Reset when the power supply is switched OFF, then ON. SM53 AC/DC DOWN detection

OFF : AC/DC DOWN

not detected ONAC/DC DOWN
  • Turn ON if an instantaneous power failure of within 10[ms] occurs during use of the AC power supply module. Reset when the power supply is switched OFF, then ON.
  • Turn ON if the voltage of external battery reduces to less than 2.7[V].
  • Remains ON even if the condition is restored to normal thereafter.

SM58 Battery low warning latch

OFFNormal ON : Battery low
  • Turn on when the voltage of the external battery reduces to less than 2.7[V].
  • Turn OFF when the voltage of external battery returns to normal.
SM59 Battery low warning OFFNormal ON : Battery low
  • Turn ON if there is at least one output module whose fuse has blown.
  • Remains ON even if the condition is restored to normal thereafter.
SM60 Fuse blown detection OFFNormal
ONModule with blown fuse
SM211 Clock data error OFFNo error ON : Error
  • Turn ON if an error occurs in clock data (SD210 to SD213) value, and turn OFF if no error is detected. S (Request)
OFFCPU No.1 READY

SM220

(Note-1) CPU No.1 READY

incompletion ONCPU No.1 READY
  • Turn ON if CPU No. 1 which uses Multiple CPU high speed bus can be operated between Multiple CPU.
OFFCPU No.2 READY

CPU No.2 READY complete

incompletion ONCPU No.2 READY
  • Turn ON if CPU No. 2 which uses Multiple CPU high speed bus can be operated between Multiple CPU.
OFFCPU No.3 READY

CPU No.3 READY complete

incompletion ONCPU No.3 READY
  • Turn ON if CPU No. 3 which uses Multiple CPU high speed bus can be operated between Multiple CPU.
OFFCPU No.4 READY

CPU No.4 READY complete

incompletion ONCPU No.4 READY
  • Turn ON if CPU No. 4 which uses Multiple CPU high speed bus can be operated between Multiple CPU.

SM240 No.1 CPU resetting OFF : CPU No.1 reset cancel ON : CPU No.1 resetting • Goes OFF when reset of the CPU No.1 is cancelled.

SM241 No.2 CPU resetting OFF : CPU No.2 reset cancel ON : CPU No.2 resetting • Goes OFF when reset of the CPU No.2 is cancelled.

SM242 No.3 CPU resetting OFF : CPU No.3 reset cancel ON : CPU No.3 resetting • Goes OFF when reset of the CPU No.3 is cancelled.

APP - 2

Show 10 more labels / short text on this page
detected · complete · completion · SM221 (Note-1) · completion · SM222 (Note-1) · S (Change status) · completion · SM223 (Note-1) · completion
Page 138 of the Mitsubishi Electronics Q172DCPU user manual — APP - 3
Page 138 · click to enlarge
Page 138

APPENDICES

Table 1.1 Special relay list (Continued)

No. Name Meaning Details Set by (When set) Remark

SM243 No.4 CPU resetting OFF : CPU No.4 reset cancel ON : CPU No.4 resetting • Goes OFF when reset of the CPU No.4 is cancelled.

OFFCPU No.1 normal ON : CPU No.1 during stop
  • Goes OFF when the CPU No.1 is normal. (Including a continuation error)
  • Comes ON when the CPU No.1 is during stop error. (Note-2)

SM244 No.1 CPU error

OFFCPU No.2 normal ON : CPU No.2 during stop
  • Goes OFF when the CPU No.2 is normal. (Including a continuation error)
  • Comes ON when the CPU No.2 is during stop error. (Note-2)

SM245 No.2 CPU error

OFFCPU No.3 normal ON : CPU No.4 during stop
  • Goes OFF when the CPU No.3 is normal. (Including a continuation error)
  • Comes ON when the CPU No.3 is during stop error. (Note-2)

SM246 No.3 CPU error

OFFCPU No.4 normal ON : CPU No.4 during stop
  • Goes OFF when the CPU No.4 is normal. (Including a continuation error)
  • Comes ON when the CPU No.4 is during stop error. (Note-2)

SM247 No.4 CPU error

ON OFF • Normally is ON.

ON OFF • Normally is OFF. S (Main processing)

  • When the PLC ready flag (M2000) turn OFF to ON, the fixed parameters, servo parameters and limit switch output data, etc., are checked, and if no error is detected, this flag turns ON.
  • Turn OFF with PLC ready flag (M2000) OFF.

ON : PCPU READY

SM500 PCPU READY

completion OFFPCPU READY
  • Judge whether TEST mode ON or not using MT Developer.
  • If the TEST mode is not established by TEST mode request using MT Developer, the TEST mode request error flag (SM510) turns ON.
SM501 Test mode ON ONTEST mode ON OFF : Except TEST mode

SM502 External forced stop

ON : Forced stop OFF OFF : Forced stop ON • Confirm forced stop ON/OFF. S (Operation cycle)

ONDigital oscilloscope is
stop OFFDigital oscilloscope is
  • Confirm the execution of digital oscilloscope using MT Developer. S (Change status)
  • Turn ON if the TEST mode is not established by TEST mode request using MT Developer.
  • When this relay is ON, the error content is stored in the TEST mode request error register (SD510, SD511).

SM510 TEST mode request

ONAbnormal OFF : Normal
  • Turn ON when a "watchdog timer error" is detected by the Motion CPU self-diagnosis function. When the Motion CPU detects a WDT error, it executes an immediate stop without deceleration of the operating axes.
  • The error cause is stored in the "Motion CPU WDT error cause (SD512)".

SM512 Motion CPU WDT

ONAbnormal OFF : Normal
ONAt least one D714 to
  • Judge whether normal/abnormal of the register for manual pulse generator axis setting register (D714 to D719).
  • When this relay is ON, the error content is stored in the manual pulse generator axis setting error register (SD513 to SD515).

Manual pulse generator axis setting error

D719 setting is abnormal. OFFAll D714 to D719

SM513

S (Occur an error)

settings are normal.

  • Judge whether normal/abnormal of the positioning data of servo program(K) specified with the Motion SFC program, and if error is detected this flag turns ON.
  • The content of a servo program setting error is stored at SD516, SD517.
ONAbnormal OFF : Normal
  • Turn ON when the temperature of Motion CPU module becomes specified value 85[°C] (185[°F]) or more. Remains ON even if normal status is restored.

SM526 Over heat warning

OFFNormal ON : Abnormal
  • Turn ON when the temperature of Motion CPU module becomes specified value 85[°C] (185[°F]) or more. Turn OFF when the temperature of Motion CPU module returns to normal.
SM527 Over heat warning OFFNormal ON : Abnormal

APP - 3

Show 19 more labels / short text on this page
error · S (Change status) · error · error · error · SM400 Always ON · SM401 Always OFF · complete · incompletion · S (Request) · input · SM503 Digital oscilloscope · executing · executing · error · error · SM516 Servo program · setting error · latch
Page 139 of the Mitsubishi Electronics Q172DCPU user manual — APP - 4
Page 139 · click to enlarge
Page 139

APPENDICES

Table 1.1 Special relay list (Continued)

No. Name Meaning Details Set by (When set) Remark

SM528 No.1 CPU MULTR

OFF to ON :

  • Turn ON when the data read from CPU No.1 is normal by MULTR instruction.

CPU No.1 read completion

SM529 No.2 CPU MULTR

OFF to ON :

  • Turn ON when the data read from CPU No.2 is normal by MULTR instruction.

CPU No.2 read completion

SM530 No.3 CPU MULTR

OFF to ON :

  • Turn ON when the data read from CPU No.3 is normal by MULTR instruction.

CPU No.3 read completion

SM531 No.4 CPU MULTR

OFF to ON :

  • Turn ON when the data read from CPU No.4 is normal by MULTR instruction.

CPU No.4 read completion

SM801 Clock data read

OFFIgnored ON : Read request
  • When this relay is ON, clock data is read to SD210 to SD213 as BCD values. U

(Note-1) : It is used for interlock condition of Multiple CPU high speed bus dedicated instruction when a synchronous system

set in Multiple CPU synchronous startup setting of system setting. (Note-2) : The CPU No.1 is reset after the factor of the stop error is removed to cancel a stop error → Resetting is cancelled.

APP - 4

Show 6 more labels / short text on this page
complete · complete · S (Read completion) · complete · complete · request
Page 140 of the Mitsubishi Electronics Q172DCPU user manual — APP - 5
Page 140 · click to enlarge
Page 140

APPENDICES

APPENDIX 1.2 Special registers

Special registers are internal registers whose applications are fixed in the Motion CPU. For this reason, it is not possible to use these registers in Motion SFC programs in the same way that normal registers are used. However, data can be written as needed in order to control the Motion CPU. Data stored in the special registers are stored as BIN values if no special designation has been made to the contrary.

The headings in the table that follows have the following meanings.

Number • Indicates the No. of the special register.

Name • Indicates the name of the special register.

Meaning • Indicates the nature of the special register.

Details • Indicates detailed information about the nature of the special register.

  • Indicates whether the register is set by the system or user, and, if it is set by system,

when setting is performed.

S: Set by system (Motion CPU)

U: Set by user (Motion SFC program or test operation using MT Developer)

S/USet by both system (Motion CPU) and user

Indicated only if setting is done by system (Motion CPU).

Main processSet during each main processing (free time processing of the CPU)
Initial processSet only during initial processing (when power supply is turned ON, or

when executed the reset)

Status changeSet only when there is a change in status

Error : Set when error is occurred.

RequestSet only when there is a user request (Special relay, etc.)

Operation cycle : Set during each operation cycle of the Motion CPU.

APP - 5

Show 4 more labels / short text on this page
Item Explanation · <Set by> · Set by · (When set)
Page 141 of the Mitsubishi Electronics Q172DCPU user manual — SD7
Page 141 · click to enlarge
Page 141

APPENDICES

Table 1.2 Special register list

No. Name Meaning Details Set by (When set) Remark

  • Error codes for errors found by diagnosis are stored as BIN data.
  • Refer to "APPENDIX 3" for details of the error code.
  • After confirm the error content, except the stop error, it is possible to clear by ON to OFF of the Motion error detection flag (M2039).
  • Clear SD0 to SD26 by ON to OFF of the Motion error detection flag (M2039) for except the stop error after confirming the error content.

SD0 Diagnostic errors Diagnostic error

  • The year (last two digits) and month that SD0 data was updated is stored as BCD 2-digit code.

SD1

Example : January 2006 H0601 B15 B7 B0 B8 to to Month(1 to 12) Year(0 to 99)

  • The day and hour that SD0 data was updated is stored as BCD 2-digit code.

Clock time for diagnostic error occurrence

Clock time for diagnostic error occurrence

SD2

Example : 25st, 10 a.m H2510 B15 B7 B0 B8 to to Day(1 to 31) Hour(0 to 23)

  • The minute and second that SD0 data was updated is stored as BCD 2-digit code.

SD3

Second(0 to 59) B15 B7 B0 B8 to to Example : 35min., 48 sec. H3548 Minute(0 to 59)

  • Category codes which help indicate what type of information is being stored in the error common information areas (SD5 to SD15) and error individual information areas (SD16 to SD26) are stored. The category code for judging the error information type is stored.

B15 B7 B8 to to B0

S (Occur an error)

SD4 Error information categories

Error information category code

  • The common information category codes store the following codes. 0: No error 1: Module No./CPU No./Base No.
  • The individual information category codes store the following codes. 0: No error 5: Parameter No. 13:Parameter No./CPU No.

SD5

  • Common information corresponding to the diagnostic error (SD0) is stored.
  • The error common information type can be judged by SD4 (common information category code). 1: Module No./CPU No./Base No.
  • For the Multiple CPU system, Module No. or CPU No. is stored depending on the error that occurred. (Refer to corresponding error code for which No. has been stored.) CPU No.1: 1, CPU No.2: 2, CPU No.3: 3, CPU No.4: 4

SD6

SD7

SD8

SD9

SD10

SD11

SD12

SD13

SD14 No. Meaning

SD5 Module No./CPU No./Base No.

SD6 I/O No.

SD7

SD15

APP - 6

Show 9 more labels / short text on this page
code · Individual information · Common information · category codes · category codes · Error common information · Error common information · to SD15 · Empty
Page 142 of the Mitsubishi Electronics Q172DCPU user manual — APP - 7
Page 142 · click to enlarge
Page 142

APPENDICES

Table 1.2 Special register list (Continued)

No. Name Meaning Details Set by (When set) Remark

SD16

  • Individual information corresponding to the diagnostic error (SD0) is stored.
  • The error individual information type can be judged by SD4 (individual information category code). 5: Parameter No.

SD17

SD18

SD19

SD20 No. Meaning

SD21 SD16 Parameter No.

SD22

SD17

SD23

SD24

SD25 0401H :Base setting

0406H :Motion slot setting

0E00H :Multiple CPU setting (Number of Multiple CPU's)

0E01H :Multiple CPU setting (Operation mode/Multiple CPU

E008H :Multiple CPU high speed transmission area setting

(CPU specific send range setting/ (System area))

S (Occur an error)

E009H/E00AH :Multiple CPU high speed transmission area setting

SD26

E00BH :Synchronous setting

13. Parameter No./CPU No.

No. Meaning

SD16 Parameter No.

SD17 CPU No.(1 to 4)

SD18

SD53 AC/DC DOWN counter No.

Number of times for AC/DC DOWN

  • Every time the input voltage fails to or below 85[%] (AC power)/65[%] (DC power) the rating during calculation of the Motion CPU module, the value is incremented by 1 and stored in BIN code.

SD60 Fuse blown No. Module No. with blown fuse • The lowest station I/O No. of the module with the blown fuse is stored.

  • The CPU switch status is stored in the following format.

B15 B12B11 B8 B7 B4 B3 B0

SD200 Status of switch Status of CPU switch

1. 2) Not used
1. CPU switch status 0: RUN 1: STOP
2. Memory card switch Always OFF
  • The CPU operating status is stored as indicated in the following figure.

B15 B12B11 B8 B7 B4 B3 B0

1. 2)

Operating status of CPU

1. Operating status of CPU 0: RUN 2: STOP
2. STOP cause
0. RUN/STOP switch 4: Error

(Note) Priority is earliest first

APP - 7

Show 11 more labels / short text on this page
to SD26 · Empty · Error individual information · Error individual information · synchronous startup) · (Automatic refresh setting) · to SD26 · Empty · S (Main processing) · SD203 Operating status · of CPU
Page 143 of the Mitsubishi Electronics Q172DCPU user manual — SD304
Page 143 · click to enlarge
Page 143

APPENDICES

Table 1.2 Special register list (Continued)

No. Name Meaning Details Set by (When set) Remark

  • The year (last two digits) and month are stored as BCD code.

B15 B12 to B11 B8 to B7 B4 to B3 B0 to

ExampleJuly, 2006 H0607

SD210 Clock data (Year, Month)

  • The day and hour are stored as BCD code.

B15 B12 to B11 B8 to B7 B4 to B3 B0 to

Example31st, 10 a.m. H3110

SD211 Clock data (Day, Hour)

  • The minutes and seconds are stored as BCD code.

B15 B12 to B11 B8 to B7 B4 to B3 B0 to

Example35 min., 48 sec. H3548

SD212 Clock data (Minute, Second)

  • The day of week is stored as BCD code.
ExampleFriday H0005

B15 B12 to B11 B8 to B7 B4 to B3 B0 to

Clock data (Day of week)

SD213

Always set to "0".

SD290 Number of points assigned for X • Stores the number of points currently set for X devices.

SD291 Number of points assigned for Y • Stores the number of points currently set for Y devices.

SD292 Number of points assigned for M • Stores the number of points currently set for M devices.

SD293 Number of points assigned for L • Stores the number of points currently set for L devices.

SD294 Number of points assigned for B • Stores the number of points currently set for B devices.

SD295 Number of points assigned for F • Stores the number of points currently set for F devices.

SD296 Number of points assigned for SB • Stores the number of points currently set for SB devices.

SD297 Number of points assigned for V • Stores the number of points currently set for V devices.

SD298 Number of points assigned for S • Stores the number of points currently set for S devices.

SD299 Number of points assigned for T • Stores the number of points currently set for T devices.

SD300 Number of points assigned for ST • Stores the number of points currently set for ST devices.

SD301 Number of points assigned for C • Stores the number of points currently set for C devices.

SD302 Number of points assigned for D • Stores the number of points currently set for D devices.

SD303 Number of points assigned for W • Stores the number of points currently set for W devices.

Number of points assigned for SW • Stores the number of points currently set for SW devices.

SD304

APP - 8

Show 15 more labels / short text on this page
Year Month · Day Hour · Clock data · S/U (Request) · Minute Second · Day of week · Sunday · Monday · Tuesday · Wednesday · Thursday · Friday · Saturday · Device assignment · S (Initial processing)
Page 144 of the Mitsubishi Electronics Q172DCPU user manual — APP - 9
Page 144 · click to enlarge
Page 144

APPENDICES

Table 1.2 Special register list (Continued)

No. Name Meaning Details Set by (When set) Remark

SD395 Multiple CPU No. Multiple CPU No. • CPU No. of the self CPU is stored. S (Initial processing)

  • The information (Real mode axis: 0/Except real mode axis: 1) used as a real mode axis at the time of switching from real mode to virtual mode is stored. SD500 : b0 to b15 (Axis 1 to 16) SD501 : b0 to b15 (Axis 17 to 32)
  • The real mode axis information does not change at the time of switching from virtual mode to real mode

Real mode axis information register

SD500 SD501

Real mode axis information register

S (At virtual mode

  • The loading status (loading: 1/non-loading: 0) of the servo amplifier checked in initial process, and stored as the bit data. SD502 : b0 to b15 (Axis 1 to 16) SD503 : b0 to b15 (Axis 17 to 32)
  • The axis which turned from non-loading to loading status after power-on is handled as loaded. (However, the axis which turned from loading to nonloading status remains as loaded.)

Servo amplifier loading information

SD502 SD503

Servo amplifier loading information

SD504 SD505 SD506

Real mode/virtual mode switching error information

Real mode /virtual mode switching error code

  • When a mode switching error occurs in real-to-virtual or virtual-to-real mode switching, or a mode continuation error occurs in the virtual mode, its error information is stored.

S (Occur an error)

  • This signal is used to temporarily suspend SSCNET communication while servo amplifiers and/or SSCNET cables after Axis 1 are exchanged with the power supply ON in a Multiple CPU system. SD508 stores the command status for "accept waiting" or "execute waiting" during this process.

Connect/ disconnect of SSCNET

SD508

0. Connect/disconnect command accept waiting
-1Connect/disconnect execute waiting

It is operating in requirement error occurrence of the test mode, axis information

  • Each axis is stopping: 0/Operating: 1, information is stored as a bit data. SD510 : b0 to b15 (Axis 1 to Axis 16) SD511 : b0 to b15 (Axis 17 to Axis 32)

SD510 SD511

Test mode request error

  • The following error codes are stored in SD512. 1: S/W fault 1 2: Operation cycle over 3: Q bus WDT error 4: WDT error 201 to 215: Q bus H/W fault 250 to 253: Servo amplifier interface H/W fault 300: S/W fault 3 301: 15 CPSTART instructions of 8 or more points were started simultaneously. 303: S/W fault 4

Error meaning of WDT error occurs

  • Contents of the manual pulse generator axis setting error is stored when the manual pulse generator axis setting error flag (SM513) turn on. (Normal: 0/Setting error: 1) SD513 : The manual pulse generator axis setting error is stored in b0 to b2

S (Occur an error)

Manual pulse generator axis setting error information

SD513 SD514 SD515

Manual pulse generator axis setting error

(P1 to P3). The smoothing magnification setting is stored in b3 to b5 (P1 to P3). SD514 : One pulse input magnification setting error is stored in b0 to b15

(axis 1 to axis 16). SD515 : One pulse input magnification setting error is stored in b0 to b15

(axis 17 to axis 32).

Error program No. of servo program

  • When the servo program setting error flag (SM516) turns on, the erroneous servo program No. will be stored.

No.

Error code of servo program

  • When the servo program setting error flag (SM516) turns on, the error code corresponding to the erroneous setting item will be stored.

SD520 Scan time Scan time (1ms units)

  • Main cycle is stored in the unit 1ms. Setting range (0 to 65535[ms])

Maximum scan time (1ms units)

  • The maximum value of the main cycle is stored in the unit 1ms. Setting range (0 to 65535[ms])

APP - 9

Show 13 more labels / short text on this page
transition) · S (Initial processing) · Connect/ Disconnect (Status) · S (Main processing) · -2 Connect/disconnect executing · SD512 Motion CPU · WDT error cause · SD516 Error program · SD517 Error item · information · S (Main processing) · SD521 Maximum scan · time
Page 145 of the Mitsubishi Electronics Q172DCPU user manual — APP - 10
Page 145 · click to enlarge
Page 145

APPENDICES

Table 1.2 Special register list (Continued)

Mitsubishi Electronics Q172DCPU — APPENDICES diagram (page 145)
Fig. 107

No. Name Meaning Details Set by (When set) Remark

  • The time required for motion operation cycle is stored in the [µs] unit. S (Operation cycle)
  • The setting operation cycle is stored in the [µs] unit. S (Initial processing)
  • This signal is used to temporarily suspend SSCNET communication while servo amplifiers and/or SSCNET cables after Axis 1 are exchanged with the power supply ON in a Multiple CPU system. SD803 is required for connect/disconnect during this process.

APP - 10

Page 146 of the Mitsubishi Electronics Q172DCPU user manual — APP - 11
Page 146 · click to enlarge
Page 146

APPENDICES

APPENDIX 1.3 Replacement of special relays/special registers

When a project for Q173HCPU(-T)/Q172HCPU(-T)/Q173CPUN(-T)/Q172CPUN(-T)/ Q173CPU/Q172CPU is converted into a project for Q173DCPU/Q172DCPU using the "Project management - File diversion" in MT Developer, special relays (M9000 to M9255) and special registers (D9000 to D9255) are automatically converted into new special relays (SM2000 to SM2255) and special registers (SD2000 to SD2255) respectively. However, in order to maintain the same functionality the user must manually convert them to the special relays and special registers shown in Table 1.3 and Table 1.4 below for Q173DCPU/Q172DCPU.

Table 1.3 Replacement of special relays

Mitsubishi Electronics Q172DCPU — Table 1.3 Replacement of special relays diagram (page 146)
Fig. 108 · Table 1.3 Replacement of special relays

M9060 SM2060 — Diagnostic error reset Use M2039 for error reset operation.

M9077 SM2077 SM513 Manual pulse generator axis setting error

APP - 11

Page 147 of the Mitsubishi Electronics Q172DCPU user manual — APP - 12
Page 147 · click to enlarge
Page 147

APPENDICES

Table 1.4 Replacement of special registers

Mitsubishi Electronics Q172DCPU — APPENDICES diagram (page 147)
Fig. 109

D9010 SD2010 SD1 Clock time for diagnostic error occurrence (Year, month)

D9011 SD2011 SD2 Clock time for diagnostic error occurrence (Day, hour)

D9012 SD2012 SD3 Clock time for diagnostic error occurrence (Minute, second)

D9060 SD2060 — Diagnostic error reset error No. Use M2039 for error reset operation.

D9197 SD2197 SD523 Operation cycle of the Motion CPU setting

APP - 12

Page 148 of the Mitsubishi Electronics Q172DCPU user manual — APP - 13
Page 148 · click to enlarge
Page 148

APPENDICES

APPENDIX 2 System Setting Errors

Motion CPUs generate a system configuration error under the following conditions.

Table 2.1 System Setting Errors

Error name 7-segment LED (Note-1)

LAY ERROR (SL )

  • The slot set in system settings is vacant or a different module is installed.
  • The axis No. setting overlaps in the system settings.
  • The axis No. (function select switch) setting of servo amplifier overlaps in the same SSCNET system.

AXIS No. MULTIDEF

AMP No. SETTING • Not a single axis is set in system settings.

  • System setting data is not written.
  • System setting data is written without relative check. Or it is written at the state of error occurrence.

SYS.SET DATA ERR

AXIS No. ERROR • System setting data is not written.

I/O POINTS OVER • The number of actual I/O points set in system settings exceeds 256.

ROM ERROR1 • Type of the operating system software of data written to ROM is different.

ROM ERROR2 • Data is not written to ROM.

Cannot be started. (Motion CPU system setting error)

  • Data size of ROM is abnormal.
  • Execute the ROM writing again.

Power supply ON/ Reset

ROM ERROR3 ( )

  • Check the adjustment for the version of Motion CPU, MT Developer and operating system software.
  • Data of ROM is abnormal.
  • Execute the ROM writing again.

ROM ERROR4 ( )

  • Check the adjustment for the version of Motion CPU, MT Developer and operating system software.
  • The motion modules that cannot be used are installed.

CAN'T USE SL ( )

  • Use the Motion modules (Q172DLX, Q173DPX, Q172DEX).
  • The system setting data that set the motion modules that cannot be used are written.
  • Use the MT Developer of version corresponding

UNIT SET ERR ( )

to the Motion modules (Q172DLX, Q173DPX, Q172DEX).

(Note-1) : "" AL" flashes 3-times "L01" display"" (Repetition) Error code is not displayed. (Note-2) : Error code stored in self-diagnostic error (SD0) (Note-3) : When the error code 10014 occurs, the system setting error flag (M2041) turns ON and the error name is displayed on the error

list monitor of MT Developer.

APP - 13

Show 10 more labels / short text on this page
Operation at · Error code · Error cause Check · error occurrence · (Note-2) · timing · "AL" flashes · 3- times · 10014 (Note-3) · "L01" display
Page 149 of the Mitsubishi Electronics Q172DCPU user manual — APP - 14
Page 149 · click to enlarge
Page 149

APPENDICES

MEMO

APP - 14

Page 150 of the Mitsubishi Electronics Q172DCPU user manual — APP - 15
Page 150 · click to enlarge
Page 150

APPENDICES

APPENDIX 3 Self-diagnosis error code

Multiple CPU related errors are stored in the CPU shared memory "self CPU operation information area (1H to 1CH)" of each module and self diagnostic error information (SD0 to SD26) of the special register (SD) as the self diagnostic errors. Error codes (1000 to 9999) of Multiple CPU related errors are common to each CPU module. The error code (10000 to 10999) is stored as required at Motion CPU-specific error occurrence. Confirm the error codes and contents by "Motion error history" on Motion CPU error batch monitor of MT Developer and remove the error cause if an error occurs.

Mitsubishi Electronics Q172DCPU — APPENDICES diagram (page 150)
Fig. 110

Confirm operation status and error occurrence of each CPU used in the Multiple CPU system by PLC diagnosis of GX Developer.

Mitsubishi Electronics Q172DCPU — APPENDICES diagram (page 150)
Fig. 111

APP - 15

Page 151 of the Mitsubishi Electronics Q172DCPU user manual — APP - 16
Page 151 · click to enlarge
Page 151

APPENDICES

(1) Multiple CPU related errors which occurs in Motion CPU

Each digit of error code has been described as follows.

Major division 1 2 3 4 5 6 7 8 9

Details code:

Tens digit Hundreds digit

:

Thousands digitMajor division (Cause)

Table 3.1 Multiple CPU related errors which occurs in Motion CPU (1000 to 9999)

Mitsubishi Electronics Q172DCPU — APPENDICES diagram (page 151)
Fig. 112

(SD16 to SD26) 7-segment LED display CPU operation status

1150 RAM ERROR — — Stop At power ON/

1300 FUSE BREAK OFF Module No. — Stop (Note-3) Always

4 digits error code is displayed in two flashes

(Note-1) : CPU No. is stored in slot No. of common information classification. (Note-2) : Base No. stored in "common information classification code" of "error information classification code" "0 : Main base, 1 to 7 : Number of extension bases. (Note-3) : CPU operation status at error occurrence can be set in the parameters. (LED display varies in conjunction with operation.)

APP - 16

Show 8 more labels / short text on this page
Internal hardware · Handling Parameter · Digit · Program Watch timer · Thousands digit · Redundant system · Multiple CPU · Outside diagnosis
Page 152 of the Mitsubishi Electronics Q172DCPU user manual — APP - 17
Page 152 · click to enlarge
Page 152

APPENDICES

(SD0) Error contents and cause Corrective action

Runaway or failure of CPU module. (1) Malfunctioning due to noise or other reason (2) Hardware fault

(1) Take noise reduction measures. (2) Reset the CPU module and RUN it again. If the same error is

displayed again, this suggests a CPU module hardware fault. Explain the error symptom and get advice from our sales representative.

1105 The CPU shared memory in the CPU module is faulty.

1150 The memory of the CPU module in the Multiple CPU high speed transmission area is faulty.

1300 There is an output module with a blown fuse. Check FUSE. LED of the output modules and replace the module whose LED is lit.

Set the Motion module/intelligent function module used in the Motion CPU in the system setting. This suggests a Motion module, intelligent function module, CPU module and/or base unit is expecting a hardware fault. Explain the error symptom and get advice from our sales representative.

1401 There was no response from the Motion module/intelligent function module in the initial processing.

1403 (1) An error is detected at the intelligent function module. (2) The I/O module (including intelligent function module) is nearly

The CPU module, base unit and/or the intelligent function module that was accessed is experiencing a hardware fault. Explain the error symptom and get advice from our sales representative.

removed or completely removed/mounted during running.

1414 An error is detected on the system bus.

Reset the CPU module and RUN it again. If the same error is displayed again, the intelligent function module, CPU module or base unit is faulty. Explain the error symptom and get advice from our sales representative.

1415 Fault of the main or extension base unit was detected.

1416 System bus fault was detected at power-on or reset.

APP - 17

Error code

Page 153 of the Mitsubishi Electronics Q172DCPU user manual — APP - 18
Page 153 · click to enlarge
Page 153

APPENDICES

Table 3.1 Multiple CPU related errors which occurs in Motion CPU (1000 to 9999)

(Continued)

Mitsubishi Electronics Q172DCPU — (Continued) diagram (page 153)
Fig. 113 · (Continued)

(SD16 to SD26) 7-segment LED display CPU operation status

4 digits error code is displayed in two flashes

Power supply 1500 AC/DC DOWN — — None Continue Always

Steady "BT1" Battery 1600 BATTERY ERROR Drive name —

4 digits error code is displayed in two flashes

APP - 18

Page 154 of the Mitsubishi Electronics Q172DCPU user manual — APP - 19
Page 154 · click to enlarge
Page 154

APPENDICES

(SD0) Error contents and cause Corrective action

Reset the CPU module and RUN it again. If the same error is displayed again, this suggests a CPU module hardware fault. Explain the error symptom and get advice from our sales representative.

1430 The error of self CPU is detected in the Multiple CPU high speed bus.

(1) Take noise reduction measures. (2) Check the main base unit mounting status of the CPU module. (3) Reset the CPU module and RUN it again. If the same error is

1431 The communication error with other CPU is detected in the Multiple CPU high speed bus.

displayed again, this suggests a CPU module or base unit hardware fault. Explain the error symptom and get advice from our sales representative.

Reset the CPU module and RUN it again. If the same error is displayed again, this suggests a CPU module hardware fault. Explain the error symptom and get advice from our sales representative.

1432 The communication time out with other CPU is detected in the Multiple CPU high speed bus.

(1) Take noise reduction measures. (2) Check the main base unit mounting status of the CPU module. (3) Reset the CPU module and RUN it again. If the same error is displayed

The communication error with other CPU is detected in the Multiple CPU high speed bus.

again, this suggests a CPU module or base unit hardware fault. Explain the error symptom and get advice from our sales representative.

1500 A momentary power supply interruption has occurred. The power supply went off. Check the power supply.

(1) The battery voltage in the CPU module has dropped below

stipulated level. (2) The battery holder unit that install the battery is not mounted to the

(1) Change the battery. (2) Mount the battery holder unit that installs the battery.

CPU module.

Make the PLC parameter's I/O assignment setting again so it is consistent with the actual status of the intelligent function module and the CPU module.

2100 In the I/O assignment setting of PLC CPU, the intelligent function module was allocated to an I/O module or vice versa.

2107 The first I/O No. set in the system settings is overlapped with the one for another module.

Make the I/O No. setting again so it is consistent with the actual status of the modules.

2124 (1) A module is mounted on the 65th or higher slot. (2) The extension base unit set to "None" is mounted.

(1) Remove the module mounted on the 65th or later slot. (2) Remove the extension base unit set to "None".

(1) Install an usable module. (2) The intelligent function module is experiencing a hardware fault.

2125 (1) A module which the CPU cannot recognise has been mounted. (2) There was no response form the intelligent function module.

Explain the error symptom and get advice from our sales representative.

2140 The motion modules (Q172DLX, Q172DEX, Q173DPX, Q172LX, Q172EX (-S1/-S2/-S3), Q173PX (-S1)) are installed in CPU slot or I/O 0 to 2 slot.

Remove the Motion modules installed CPU slot or I/O 0 to 2 slot.

(1) Change to the intelligent function module (function version B or later)

2150 In a Multiple CPU system, the control CPU of intelligent function module incompatible with the Multiple CPU system is set to other than CPU No.1.

compatible with the Multiple CPU system. (2) Change the control CPU of intelligent function module incompatible with

the Multiple CPU system to CPU No.1.

APP - 19

Error code

Page 155 of the Mitsubishi Electronics Q172DCPU user manual — APP - 20
Page 155 · click to enlarge
Page 155

APPENDICES

Table 3.1 Multiple CPU related errors which occurs in Motion CPU (1000 to 9999)

(Continued)

Mitsubishi Electronics Q172DCPU — (Continued) diagram (page 155)
Fig. 114 · (Continued)

(SD16 to SD26) 7-segment LED display CPU operation status

4 digits error code is displayed in two flashes

(Note-1) : CPU No. is stored in slot No. of common information classification. (Note-4) : Because a stop error or CPU No. except CPU No. that it was reset becomes MULTI CPU DOWN simultaneously, a stop error or CPU No. except CPU

No. that it was reset may store in the classification of common error information depending on timing.

APP - 20

Page 156 of the Mitsubishi Electronics Q172DCPU user manual — APP - 21
Page 156 · click to enlarge
Page 156

APPENDICES

(SD0) Error contents and cause Corrective action

(1) Check the parameter item corresponding the numerical value

(parameter No.), and correct it. (2) Rewrite corrected parameters to the CPU module, reload or reset the

3001 The parameter settings are corrupted.

Multiple CPU system power supply. (3) If the same error occurs, it is thought to be a hardware error.

Explain the error symptom and get advice from our sales representative.

3012 Multiple CPU setting of Multiple CPU setting parameter or control CPU setting of system setting differs from that of the reference CPU settings.

Match the Multiple CPU setting of Multiple CPU setting parameter or control CPU setting of system setting with that of the reference CPU (CPU No.1) settings.

Check the following in the Multiple CPU automatic refresh setting and make correction. (1) When specifying the bit device, specify a multiple of 16 for the refresh

Multiple CPU automatic refresh setting is any of the following. (1) When a bit device is specified as a refresh device, a number other

than a multiple of 16 is specified for the refresh start device. (2) The device specified is other than the one that may be specified. (3) The number of send points is an odd number. (4) The total number of send points is greater than the maximum

start device. (2) Specify the device that may be specified for the refresh device. (3) Set the number of send points to an even number. (4) Set the total number of send points is within the range of the maximum

number of refresh points.

number of refresh points.

(1) Set "Use multiple CPU high speed transmission " in the Universal

(1) "Use multiple CPU high speed transmission " is not set in the

module QCPU. (2) Check the parameter item corresponding to the numerical value

Multiple CPU setting of Universal module QCPU. (2) In a Multiple CPU system, the CPU verified is different from the

(parameter No./CPU No.) and parameter of target CPU, and correct them.

one set in the parameter setting.

In the operating mode of a Multiple CPU system, a CPU error occurred at the CPU where "All station stop by stop error of CPU" was selected.

Check the error of the CPU resulting in CPU module fault, and remove the errors.

7000 In a Multiple CPU system, CPU No.1 resulted in stop error at power- on and the other CPU cannot start. (This error occurred at CPU No.2 to 4)

Reset the CPU module and RUN it again. If the same error is displayed again, this suggests the hardware fault of any of the CPU modules. Explain the error symptom and get advice from our sales representative.

7002 There is no response from the target CPU module in a Multiple CPU system during initial communication.

7010 In a Multiple CPU system, a faulty CPU module was mounted. Replace the faulty CPU module.

Either of the following settings was made in a Multiple CPU system. (1) Multiple CPU automatic refresh setting was made for the

(1) Correct the Multiple CPU automatic refresh setting. (2) Correct the "I/O sharing when using multiple CPUs" setting.

inapplicable CPU module. (2) "I/O sharing when using multiple CPUs" setting was made for the

inapplicable CPU module.

7011 The system configuration for using the Multiple CPU high speed transmission function is not met. (1) The QnUD(H)CPU is not used for the CPU No.1. (2) The Multiple CPU high speed main base unit (Q3 DB) is not used.

Change to the system configuration to meet the conditions for using the Multiple CPU high speed transmission function.

7013 (1) CPU module which cannot be mounted in OnCPU(H)CPU is

mounted. (The module may break down.) (2) Q173HCPU,Q172HCPU,Q173CPUN,Q172CPUN is mounted.

Remove Q173HCPU,Q172HCPU,Q173CPUN,Q172CPUN.

7020 In the operating mode of a Multiple CPU system, an error occurred in the CPU where "system stop" was not selected. (The CPU module where no error occurred was used to detect an error.)

Check the error of the CPU resulting in CPU module fault, and remove the error.

7030 An assignment error occurred in the CPU-mountable slot (CPU slot, I/O slot 0 to 2) in excess of the number of CPU slot (with in the range of CPU number setting parameter).

(1) Set the same value to the number of CPU modules specified in the

Multiple CPU setting of the PLC parameter and the number of mounted CPU modules (including CPU (empty)). (2) Make the same as the state of the installation of CPU module set in the

7031 An assignment error occurred in the CPU slot (within the range of the CPU number setting parameter).

system setting.

7035 The CPU module has been mounted on the inapplicable slot. Mount the CPU module on the applicable slot.

APP - 21

Error code

Page 157 of the Mitsubishi Electronics Q172DCPU user manual — APP - 22
Page 157 · click to enlarge
Page 157

APPENDICES

(2) Motion CPU-specific errors

Each digit of error code has been described as follows. Refer to programming manuals for error details.

Details code 1 0

Mitsubishi Electronics Q172DCPU — APPENDICES diagram (page 157)
Fig. 115

003 004 005 006 007 008 009 010 011 014 016 020 021 022 023 030

Minor/major error (Virtual servomoter axis)(SV22) Minor/major error (Synchronous encoder axis)(SV22)

Details code:

Tens digit Hundreds digit

:

: Positioning CPU division (0 : Motion CPU)

Ten thousands digitExcept PLC CPU

WDT error System setting error Motion slot fault Motion SFC control error (F/FS)

Motion SFC control error (G) Motion SFC control error (K or others (Not F/FS, G)) Motion SFC control error (Motion SFC chart)

Table 3.2 Motion CPU-specific errors (10000 to 10999)

Mitsubishi Electronics Q172DCPU — Table 3.2 Motion CPU-specific errors (10000 to 10999) diagram (page 157)
Fig. 116 · Table 3.2 Motion CPU-specific errors (10000 to 10999…

(SD16 to SD26) 7-segment LED display CPU status operation

APP - 22

Digit · Thousands digit

Page 158 of the Mitsubishi Electronics Q172DCPU user manual — APP - 23
Page 158 · click to enlarge
Page 158

APPENDICES

(SD0) Error contents and cause Corrective action

10003 Minor/major errors had occurred.

Check the Motion error history of MT Developer and the minor/major error codes of minor/major error code of minor/major error code storage device, and remove the error cause. Refer to the error codes for error details of minor/major errors.

10004 Minor/major errors had occurred in virtual servomotor axis. (SV22)

10005 Minor/major errors had occurred in synchronous encoder axis. (SV22)

Check the Motion error history of MT Developer and the servo error codes of servo error code storage device, and remove the error cause of servo amplifier. Refer to the servo error code for details of servo errors.

10006 The servo errors had occurred in the servo amplifier connected to the Motion CPU.

Check the Motion error history of MT Developer and the servo program setting error storage device (error program No., error item information), and remove the error cause. Refer to the servo program setting error codes for details of servo program setting errors.

10007 Servo program setting error occurred.

Check the Motion error history of MT Developer and the real mode/virtual mode switching error storage device, and remove the error cause. Refer to the real mode/virtual mode switching error codes for details of real mode/virtual mode switching errors.

10008 Real mode/virtual mode switching error occurred. (SV22)

Check the Motion error history of MT Developer and the manual pulse generator axis setting error storage device, and remove the error cause. Refer to the manual pulse generator axis setting error codes for details of manual pulse generator axis setting errors.

10009 Manual pulse generator axis setting error occurred.

10010 Test mode request error occurred. Check the Motion error history of MT Developer and the test mode request error storage device, and remove the error cause.

10011 WDT error occurred at Motion CPU. Check the Motion error history of MT Developer and the Motion CPU WDT error factors, and remove the error cause.

10014 System setting error occurred at Motion CPU.

Check the error message on error monitor screen of MT Developer, and remove the error cause. And then, turn on the power supply again or reset the Multiple CPU system.

10016 Motion slot fault occurred at Motion CPU.

Check the Motion error history of MT Developer, and remove the error cause. Refer to the Motion SFC error code for details of errors.

Motion SFC error occurred at Motion SFC program.

10030 Motion CPU internal bus error occurred. Motion CPU module hardware fault. Explain the error symptom and get advice from our sales representative.

APP - 23

Error code

Page 159 of the Mitsubishi Electronics Q172DCPU user manual — SD18
Page 159 · click to enlarge
Page 159

APPENDICES

(3) Self-diagnostic error information

No. Name Meaning Details

SD0 Diagnostic errors Diagnostic error

code • Error codes for errors found by diagnosis are stored as BIN data.

  • The year (last two digits) and month that SD0 data was updated is stored as BCD 2-digit code.

Example : January 2006 H0601 B15 B7 B0 B8 to to Month(1 to 12) Year(0 to 99)

SD1

  • The day and hour that SD0 data was updated is stored as BCD 2-digit code.

Clock time for diagnostic error occurrence

Clock time for diagnostic error occurrence

SD2

Example : 25st, 10 a.m H2510 B15 B7 B0 B8 to to Day(1 to 31) Hour(0 to 23)

  • The minute and second that SD0 data was updated is stored as BCD 2-digit code.

Second(0 to 59) B15 B7 B0 B8 to to Example : 35min., 48 sec. H3548 Minute(0 to 59)

SD3

  • Category codes which help indicate what type of information is being stored in the error common information areas (SD5 to SD15) and error individual information areas (SD16 to SD26) are stored. The category code for judging the error information type is stored.

B15 B7 B8 to to B0

  • The common information category codes store the following codes. 0: No error 1: Module No./CPU No./Base No.
  • The individual information category codes store the following codes. 0: No error 5: Parameter No. 13:Parameter No./CPU No.

SD4 Error information categories

Error information category code

  • Common information corresponding to the diagnostic error (SD0) is stored.
  • The error common information type can be judged by SD4(common information category code). 1: Module No./CPU No./Base No.

No. Meaning

SD5

SD5 Module No./CPU No./Base No.

SD6 I/O No.

SD7

  • Individual information corresponding to the diagnostic error (SD0) is stored.
  • The error individual information type can be judged by SD4(individual information category code). 5: Parameter No.

No. Meaning

SD16 Parameter No.

SD17

0401H :Base setting

0406H :Motion slot setting

0E00H :Multiple CPU setting (Number of Multiple CPU's)

SD16

0E01H :Multiple CPU setting (Operation mode/ Multiple CPU synchronous startup)

E008H :Multiple CPU high speed transmission area setting

(CPU specific send range setting / (System area))

E009H/E00AHMultiple CPU high speed transmission area setting(Automatic refresh setting)

E00BH :Synchronous setting

13. Parameter No./CPU No.

No. Meaning

SD16 Parameter No.

SD17 CPU No.(1 to 4)

SD18

APP - 24

Show 16 more labels / short text on this page
Individual information · Common information · category codes · category codes · Error common information · Error common information · to SD15 · to SD15 · Empty · to SD26 · Empty · Error individual information · Error individual information · to SD26 · to SD26 · Empty
Page 160 of the Mitsubishi Electronics Q172DCPU user manual — APP - 25
Page 160 · click to enlarge
Page 160

APPENDICES

(4) Release of Multiple CPU related error

The release operation of errors that continues operation for CPU can be executed. Release the errors in the following procedure. 1) Remove the error cause. 2) Turn off the Motion error detection flag (M2039).

The special relays, special registers and 7-segment LED for the errors are returned to the status before error occurs after release of errors. If the same error is displayed again after release of errors, an error is set again, and the Motion error detection flag (M2039) turns on.

APP - 25

Page 161 of the Mitsubishi Electronics Q172DCPU user manual — APP - 26
Page 161 · click to enlarge
Page 161

APPENDICES

APPENDIX 4 Differences Between Q173DCPU/Q172DCPU and Q173HCPU/Q172HCPU

APPENDIX 4.1 Differences Between Q173DCPU/Q172DCPU and Q173HCPU/Q172HCPU

Common differences to each mode are shown in Table 4.1. Refer to "APPENDIX 4.3 Differences of each mode" for characteristic differences to each mode. And, refer to "APPENDIX 4.2 Comparison of devices " for detailed differences of devices. Table 4.1 Differences Between Q173DCPU/Q172DCPU and Q173HCPU/Q172HCPU

Peripheral I/F Via PLC CPU (USB/RS-232) USB/SSCNET

External battery Demand Add Q6BAT at continuous power failure for 1 month or more.

  • Use EMI terminal of Motion CPU module.
  • Use device set by forced stop input setting in the system setting.
  • Use device set by forced stop input setting in the system setting.

Multiple CPU high speed transmission memory for data transfer between CPU modules

Internal relays (M) 8192 points

Latch relays (L) None (Latch for M is possible by latch setting)

Special relays (M) — 256 points

Special relays (SM) 2256 points —

Special registers (D) — 256 points

Special registers (SD) 2256 points —

Motion registers (#) 8736 points 8192 points

Multiple CPU area devices (U \G) Up to 14336 points —

D(P).DDRD, D(P).DDWR, D(P).SFCS, D(P).SVST, D(P).CHGT, D(P).CHGV, D(P).CHGA, D(P).GINT

S(P).DDRD, S(P).DDWR, S(P).SFCS, S(P).SVST, S(P).CHGT, S(P).CHGV, S(P).CHGA, S(P).GINT

Motion dedicated PLC instructions

Multiple instructions are executable continuously without interlock condition by the self CPU high speed interrupt accept flag from CPU . :CPU No.

Interlock condition by the to self CPU high speed interrupt accept flag from CPU is necessary.

Motion modules Q172DLX, Q172DEX, Q173DPX Q172LX, Q172EX, Q173PX

  • QnUD(H)CPU is set as CPU No. 1.
  • Only Multiple CPU high speed main base unit (Q38DB/Q312DB) can be used as main base unit.
  • Motion modules cannot be installed to I/O 0 to 2 slot.
  • QnUD(H)CPU is set to CPU No. 1.
  • Q3 B can be used as a main base unit.
  • Motion modules can be mounted to I/O 0 to 2 slot.

Latch clear Remote operation L.CLR switch

RUN/STOP Remote operation, RUN/STOP switch RUN/STOP switch

  • ROM writing is executed with mode operated by RAM/ mode operated by ROM.
  • ROM writing can be executed for the data of MT Developer.

Rom writing is executed with installation mode/ mode written in ROM.

APP - 26

Show 8 more labels / short text on this page
Item Q173DCPU/Q172DCPU Q173HCPU/Q172HCPU · Forced stop input · Included — · Total 8192 points · Device · Interlock condition · System setting · ROM operation
Page 162 of the Mitsubishi Electronics Q172DCPU user manual — APP - 27
Page 162 · click to enlarge
Page 162

APPENDICES

Table 4.1 Differences Between Q173DCPU/Q172DCPU and Q173HCPU/Q172HCPU

(Continued)

Medium of operating system software CD-ROM (1 disk) FD (2 disks)

Model of operating system software SW8DNC-SV Q SW6RN-SV Q

CPU module No.1 QnUD(H)CPU Qn(H)CPU

Installation orders CPU No.2 or later No restriction Install Motion CPU module on the right-hand side of PLC CPU module.

Combination of Motion CPU modules Q173DCPU/Q172DCPU only Combination with Q173CPUN(-T)/Q172CPUN(-T).

CPU empty slot Settable between CPU modules Not settable between CPU modules

Multiple CPU high speed transmission area

Provided None CPU shared memory

Access by Multiple CPU shared memory Possible Impossible

Memory Multiple CPU high speed transmission area in CPU shared memory Automatic refresh area in CPU shared memory

Automatic refresh setting 32 range possible 4 range possible Automatic refresh

Multiple CPU high speed refresh function

LED display 7-segment LED display Each LED of MODE, RUN, ERR, M.RUN, BAT

Range which can be cleared with the latch clear key. Latch range setting

Latch (1) It is possible to clear with latch clear(1) and latch clear (1)(2) of remote latch clear.

Latch (2) It is possible to clear with lath clear(1)(2) of remote latch clear.

Range which cannot be cleared with the latch clear key.

All clear function Execute with installation mode Turn off the PLC ready flag (M2000) and test mode ON flag (M9075) to execute all clear.

Store the error code to be released in the special register D9060 and turn off to on the special relay M9060.

Release of Multiple CPU related error Turn off M2039.

APP - 27

Item Q173DCPU/Q172DCPU Q173HCPU/Q172HCPU · Provided None · and BOOT

Page 163 of the Mitsubishi Electronics Q172DCPU user manual — APP - 28
Page 163 · click to enlarge
Page 163

APPENDICES

APPENDIX 4.2 Comparison of devices

(1) Motion registers

Table 4.2 Motion registers (Monitor devices) list

Mitsubishi Electronics Q172DCPU — APPENDICES diagram (page 163)
Fig. 117

#8000 to #8019 #8064 to #8067 Axis 1 monitor device

#8020 to #8039 #8068 to #8071 Axis 2 monitor device

#8040 to #8059 #8072 to #8075 Axis 3 monitor device

#8060 to #8079 #8076 to #8079 Axis 4 monitor device

#8080 to #8099 #8080 to #8083 Axis 5 monitor device

#8100 to #8119 #8084 to #8087 Axis 6 monitor device

#8120 to #8139 #8088 to #8091 Axis 7 monitor device

#8140 to #8159 #8092 to #8095 Axis 8 monitor device

#8160 to #8179 #8096 to #8099 Axis 9 monitor device

#8180 to #8199 #8100 to #8103 Axis 10 monitor device

#8200 to #8219 #8104 to #8107 Axis 11 monitor device

#8220 to #8239 #8108 to #8111 Axis 12 monitor device

#8240 to #8259 #8112 to #8115 Axis 13 monitor device

#8260 to #8279 #8116 to #8119 Axis 14 monitor device

#8280 to #8299 #8120 to #8123 Axis 15 monitor device

#8300 to #8319 #8124 to #8127 Axis 16 monitor device

#8320 to #8339 #8128 to #8131 Axis 17 monitor device

#8340 to #8359 #8132 to #8135 Axis 18 monitor device

#8360 to #8379 #8136 to #8139 Axis 19 monitor device

#8380 to #8399 #8140 to #8143 Axis 20 monitor device

#8400 to #8419 #8144 to #8147 Axis 21 monitor device

#8420 to #8439 #8148 to #8151 Axis 22 monitor device

#8440 to #8459 #8152 to #8155 Axis 23 monitor device

#8460 to #8479 #8156 to #8159 Axis 24 monitor device

#8480 to #8499 #8160 to #8163 Axis 25 monitor device

#8500 to #8519 #8164 to #8167 Axis 26 monitor device

#8520 to #8539 #8168 to #8171 Axis 27 monitor device

#8540 to #8559 #8172 to #8175 Axis 28 monitor device

#8560 to #8579 #8176 to #8179 Axis 29 monitor device

#8580 to #8599 #8180 to #8183 Axis 30 monitor device

#8600 to #8619 #8184 to #8187 Axis 31 monitor device

#8620 to #8639 #8188 to #8191 Axis 32 monitor device

APP - 28

(a) Monitor devices

Page 164 of the Mitsubishi Electronics Q172DCPU user manual — APP - 29
Page 164 · click to enlarge
Page 164

APPENDICES

Table 4.3 Monitor devices list

Mitsubishi Electronics Q172DCPU — APPENDICES diagram (page 164)
Fig. 118

#8000 + 20n #8064 + 4n Servo amplifier type

#8004 + 20n #8005 + 20n — Command speed

#8006 + 20n #8007 + 20n — Home position return re-travel value

(Note-1) : "n" in the above device No. indicates the numerical value which correspond to axis No.

(b) Motion error history

Table 4.4 Motion registers (Motion error history) list

Mitsubishi Electronics Q172DCPU — Table 4.4 Motion registers (Motion error history) list diagram (page 164)
Fig. 119 · Table 4.4 Motion registers (Motion error history) li…

#8640 to #8651 #8000 to #8007 Seventh error information in past (Oldest error information)

#8652 to #8663 #8008 to #8015 Sixth error information in past

#8664 to #8675 #8016 to #8023 Fifth error information in past

#8676 to #8687 #8024 to #8031 Fourth error information in past

#8688 to #8699 #8032 to #8039 Third error information in past

#8700 to #8711 #8040 to #8047 Second error information in past

#8712 to #8723 #8048 to #8055 First error information in past

#8724 to #8735 #8056 to #8063 Latest error information

Table 4.5 Motion error history list

Mitsubishi Electronics Q172DCPU — Table 4.5 Motion error history list diagram (page 164)
Fig. 120 · Table 4.5 Motion error history list

#8640 + 12n #8000 + 8n Error Motion SFC program No.

#8642 + 12n #8002 + 8n Error program No.

#8643 + 12n #8003 + 8n Error block No./Motion SFC list/Line No./Axis No.

#8645 + 12n #8005 + 8n Error occurrence time (Year/month

#8646 + 12n #8006 + 8n Error occurrence time (Day/hour)

#8647 + 12n #8007 + 8n Error occurrence time (Minute/second)

#8650 + 12n #8651 + 12n — Error setting data

(Note-1) : "n" in the above device No. indicates the numerical value which correspond to axis No.

APP - 29

Page 165 of the Mitsubishi Electronics Q172DCPU user manual — APP - 30
Page 165 · click to enlarge
Page 165

APPENDICES

(2) Special relays

Table 4.6 Special relay list

Mitsubishi Electronics Q172DCPU — APPENDICES diagram (page 165)
Fig. 121

— M9060/M3138 Diagnostic error reset Use M2039 for error reset operation.

APP - 30

Page 166 of the Mitsubishi Electronics Q172DCPU user manual — APP - 31
Page 166 · click to enlarge
Page 166

APPENDICES

(3) Special registers

Table 4.7 Special registers list

Mitsubishi Electronics Q172DCPU — APPENDICES diagram (page 166)
Fig. 122

SD1 D9010 Clock time for diagnostic error occurrence (Year, month)

SD2 D9011 Clock time for diagnostic error occurrence (Day, hour)

SD3 D9012 Clock time for diagnostic error occurrence (Minute, second)

— D9060 Diagnostic error reset error No. Use M2039 for error reset operation.

APP - 31

Page 167 of the Mitsubishi Electronics Q172DCPU user manual — APP - 32
Page 167 · click to enlarge
Page 167

APPENDICES

Table 4.7 Special registers list (Continued)

Mitsubishi Electronics Q172DCPU — APPENDICES diagram (page 167)
Fig. 123

SD523 D9197 Operation cycle of the Motion CPU setting

— D9201 State of LED Use 7-segment LED in Q173DCPU/Q172DCPU.

APP - 32

Page 168 of the Mitsubishi Electronics Q172DCPU user manual — APP - 33
Page 168 · click to enlarge
Page 168

APPENDICES

(4) Other devices

Table 4.8 Other devices list

M2320 to M2399 Unusable Special relay allocated devices (Status)

M2400 to M3039 Device area of 9 axes or more is usable as user devices in Q172DCPU.

Device area of 9 axes or more is unusable as user devices in Q172HCPU.

Internal relays/ Data registers

M3136 to M3199 Unusable Special relay allocated devices (Command signal)

Device area of 9 axes or more is usable as user devices in Q172DCPU.

Device area of 9 axes or more is unusable in Q172HCPU.

Personal computer link communication error flag — M2034

PCPU READY complete SM500 D759

D9 + 20n (Data shortened to 1 word) (Note-1)

D9 + 20n (Note-1)

Home position return re-travel value #8006 + 20n, #8007 + 20n (Referring at monitoring) (Note-1)

Optional device (Set for D16 + 20n, D17 + 20n are also usable.)

Travel value change registers

D16 + 20n, D17 + 20n (Note-1)

D0 to D8191 D800 to D8191

Indirect setting devices (Word devices)

W0 to W1FFF W0 to W1FFF

#0 to #7999 #0 to #7999

U \G10000 to U \G(10000 + p – 1) (Note-2) —

X0 to X1FFF X0 to X1FFFF

Y0 to Y1FFF Y0 to Y1FFF

M0 to M8191 M/L0 to M/L8191

Indirect setting devices (Bit devices)

— M9000 to M9255

B0 to B1FFF B0 to B1FFF

F0 to F2047 F0 to F2047

U \G10000.0 to U \G(10000 + p – 1).F (Note-2) —

D0 to D8191 D800 to D3069, D3080 to D8191

High-speed reading function settable devices

W0 to W1FFF W0 to W1FFF

U \G10000 to U \G(10000 + p – 1) (Note-2) —

D0 to D8191 D0 to D8191

W0 to W1FFF W0 to W1FFF

Optional data monitor function settable devices

#0 to #7999 #0 to #7999

U \G10000 to U \G(10000 + p – 1) (Note-2) —

(Note-1) : "n" in the above device No. indicates the numerical value which correspond to axis No. (Note-2) : "p" indicates the user setting area points of Multiple CPU high speed transmission area in each CPU.

APP - 33

Show 5 more labels / short text on this page
Item Q173DCPU/Q172DCPU Q173HCPU/Q172HCPU · M3200 to M3839 · D0 to D639 · D640 to D703 · (Note-1)
Page 169 of the Mitsubishi Electronics Q172DCPU user manual — APP - 34
Page 169 · click to enlarge
Page 169

APPENDICES

Table 4.8 Other devices list (Continued)

Mitsubishi Electronics Q172DCPU — APPENDICES diagram (page 169)
Fig. 124

U \G10000.0 to U \G(10000 + p –1).F (Note-2) —

U \G10000 to U \G(10000 + p –1) (Note-2) —

U \G10000 to U \G(10000 + p – 1) (Note-2) —

U \G10000.0 to U \G(10000 + p – 1).F (Note-2) —

(Note-2) : "p" indicates the user setting area points of Multiple CPU high speed transmission area in each CPU. (Note-3) : Setting range varies depending on the setting units.

Mitsubishi Electronics Q172DCPU — APPENDICES diagram (page 169)
Fig. 125

POINT Refer to Chapter 2 for number of user setting area points of Multiple CPU high speed transmission area.

APP - 34

Page 170 of the Mitsubishi Electronics Q172DCPU user manual — APP - 35
Page 170 · click to enlarge
Page 170

APPENDICES

APPENDIX 4.3 Differences of each mode

(1) Motion SFC

Table 4.9 Differences in Motion SFC mode

Mitsubishi Electronics Q172DCPU — APPENDICES diagram (page 170)
Fig. 126

Motion SFC program executing flag X, Y, M, B, U \G —

Operation control/transition control usable device (Word device) D, W, U \G, SD, #, FT D, W, Special D, #, FT

Operation control/transition control usable device (Bit device) X, PX, Y, PY, M, U \G . , B, F, SM X, PX, Y, PY, M, L, B, F, Special M

(2) Virtual mode

Table 4.10 Differences in Virtual mode

M5440 to M5487 Internal relay/ Data register

Device area of 9 axes or more is usable as user devices in the Q172DCPU.

Device area of 9 axes or more is unusable in the Q172HCPU.

Clutch status Optional device (Set for M2160 to M2223 are also usable.) M2160 to M2223

Cam axis command signals (Cam/ball screw switching command)

Optional device (Set for M5488 to M5519 are also usable.) M5488 to M5519

Smoothing clutch complete signals Optional device (Set for M5520 to M5583 are also usable.) M5520 to M5583

Real mode axis information register SD500, SD501 D790, D791

D0 to D8191 D800 to D3069, D3080 to D8191

Indirect setting devices of mechanical system program (Word device)

W0 to W1FFF W0 to W1FFF

#0 to #7999 —

U \G10000 to U \G(10000 + p –1 ) (Note-1) —

X0 to X1FFF X0 to X1FFF

Y0 to Y1FFF Y0 to Y1FFF

Indirect setting devices of mechanical system program (Bit device)

M0 to M8191 M/L0 to M/L8191

— M9000 to M9255

B0 to B1FFF B0 to B1FFF

F0 to F2047 F0 to F2047

U \G10000.0 to U \G(10000 + p –1 ).F (Note-1) —

Speed change ratio of speed change gear

Upper limit value0 to 65535 Lower limit value : 0 to 65535
Upper limit value1 to 10000 Lower limit value : 1 to 10000

Permissible droop pulse value of output module 1 to 1073741824 [PLS] 1 to 65535[∗100PLS]

(Note-1) : "p" indicates user setting area points of Multiple CPU high speed transmission area in each CPU.

Mitsubishi Electronics Q172DCPU — (2) Virtual mode diagram (page 170)
Fig. 127 · (2) Virtual mode

POINT Refer to Chapter 2 for number of user setting area points of Multiple CPU high speed transmission area.

APP - 35

Item Q173DCPU/Q172DCPU Q173HCPU/Q172HCPU · M4640 to M4687 · D1120 to D1239

Page 171 of the Mitsubishi Electronics Q172DCPU user manual — [ Gratis Warranty Term]
Page 171 · click to enlarge
Page 171

WARRANTY

Please confirm the following product warranty details before using this product. 1. Gratis Warranty Term and Gratis Warranty Range If any faults or defects (hereinafter "Failure") found to be the responsibility of Mitsubishi occurs during use of the product within the gratis warranty term, the product shall be repaired at no cost via the sales representative or Mitsubishi Service Company. However, if repairs are required onsite at domestic or overseas location, expenses to send an engineer will be solely at the customer's discretion. Mitsubishi shall not be held responsible for any re-commissioning, maintenance, or testing on-site that involves replacement of the failed module.

[ Gratis Warranty Term]

(1) Diagnosis of failure

As a general rule, diagnosis of failure is done on site by the customer. However, Mitsubishi or Mitsubishi service network can perform this service for an agreed upon fee upon the customer’s request. There will be no charges if the cause of the breakdown is found to be the fault of Mitsubishi.

There will be a charge for breakdown repairs, exchange replacements and on site visits for the following four conditions, otherwise there will be a charge. 1) Breakdowns due to improper storage, handling, careless accident, software or hardware design by the customer 2) Breakdowns due to modifications of the product without the consent of the manufacturer 3) Breakdowns resulting from using the product outside the specified specifications of the product 4) Breakdowns that are outside the terms of warranty

Since the above services are limited to Japan, diagnosis of failures, etc. are not performed abroad. If you desire the after service abroad, please register with Mitsubishi. For details, consult us in advance. 2. Exclusion of Loss in Opportunity and Secondary Loss from Warranty Liability Mitsubishi will not be held liable for damage caused by factors found not to be the cause of Mitsubishi; opportunity loss or lost profits caused by faults in the Mitsubishi products; damage, secondary damage, accident compensation caused by special factors unpredictable by Mitsubishi; damages to products other than Mitsubishi products; and to other duties. 3. Onerous Repair Term after Discontinuation of Production Mitsubishi shall accept onerous product repairs for seven years after production of the product is discontinued. 4. Delivery Term In regard to the standard product, Mitsubishi shall deliver the standard product without application settings or adjustments to the customer and Mitsubishi is not liable for on site adjustment or test run of the product. 5. Precautions for Choosing the Products (1) These products have been manufactured as a general-purpose part for general industries, and have not been

designed or manufactured to be incorporated in a device or system used in purposes related to human life. (2) Before using the products for special purposes such as nuclear power, electric power, aerospace, medicine,

passenger movement vehicles or under water relays, contact Mitsubishi. (3) These products have been manufactured under strict quality control. However, when installing the product where

major accidents or losses could occur if the product fails, install appropriate backup or failsafe functions in the system. (4) When exporting any of the products or related technologies described in this catalogue, you must obtain an

export license if it is subject to Japanese Export Control Law.

(2) Breakdown repairs

Page 172 of the Mitsubishi Electronics Q172DCPU user manual — IB(NA)-0300134-A(0801)MEE
Page 172 · click to enlarge
Page 172
Mitsubishi Electronics Q172DCPU — WARRANTY diagram (page 172)
Fig. 128
HEAD OFFICETOKYO BUILDING, 2-7-3 MARUNOUCHI, CHIYODA-KU, TOKYO 100-8310, JAPAN

MODEL

Q173D-P-COM-E

MODEL

1XB928

CODE

IB(NA)-0300134-A(0801)MEE

When exported from Japan, this manual does not require application to the Ministry of Economy, Trade and Industry for service transaction permission.

IB(NA)-0300134-A(0801)MEE

Specifications subject to change without notice.

Page 173 of the Mitsubishi Electronics Q172DCPU user manual — WARRANTY
Page 173 · click to enlarge
Page 173
Page 173 of the Mitsubishi Electronics Q172DCPU user manual — WARRANTY
Page 174 of the Mitsubishi Electronics Q172DCPU user manual — MITSUBISHI ELECTRIC FACTORY AUTOMATION
Page 174 · click to enlarge
Page 174

MITSUBISHI ELECTRIC

HEADQUARTERS

EUROPEAN REPRESENTATIVES

EUROPEAN REPRESENTATIVES

EURASIAN REPRESENTATIVES

EUROPE MITSUBISHI ELECTRIC EUROPE B.V. German Branch GothaerStraße 8 D-40880 Ratingen Phone: +49 (0)2102 / 486-0 Fax: +49 (0)2102 / 486-1120

AUSTRIA GEVA Wiener Straße 89 AT-2500 Baden Phone: +43 (0)2252 / 85 55 20 Fax: +43 (0)2252 / 488 60

MALTA ALFATRADE Ltd. 99, Paola Hill Malta- Paola PLA 1702 Phone: +356 (0)21 / 697 816 Fax: +356 (0)21 / 697 817

KAZAKHSTAN Kazpromautomatics Ltd. Mustafina Str. 7/2 KAZ-470046 Karaganda Phone: +7 7212 / 50 11 50 Fax: +7 7212 / 50 11 50

BELARUS TEHNIKON Oktyabrskaya 16/5, Off. 703-711 BY-220030 Minsk Phone: +375 (0)17 / 210 46 26 Fax: +375 (0)17 / 210 46 26

MOLDOVA INTEHSIS srl bld. Traian 23/1 MD-2060 Kishinev Phone: +373 (0)22 / 66 4242 Fax: +373 (0)22 / 66 4280

CZECH REPUBLIC MITSUBISHIELECTRICEUROPEB.V. Czech Branch Avenir Business Park, Radlická 714/113a CZ-158 00 Praha 5 Phone: +420 (0)251 551 470 Fax: +420 (0)251-551-471

MIDDLE EAST REPRESENTATIVES

ISRAEL ILAN & GAVISH Ltd. 24 Shenkar St., Kiryat Arie IL-49001 Petah-Tiqva Phone: +972 (0)3 / 922 18 24 Fax: +972 (0)3 / 924 0761

BELGIUM Koning & Hartman b.v. Woluwelaan 31 BE-1800 Vilvoorde Phone: +32 (0)2 / 257 02 40 Fax: +32 (0)2 / 257 02 49

NETHERLANDS Koning & Hartman b.v. Haarlerbergweg 21-23 NL-1101 CH Amsterdam Phone: +31 (0)20 / 587 76 00 Fax: +31 (0)20 / 587 76 05

FRANCE MITSUBISHI ELECTRIC EUROPE B.V. French Branch 25, Boulevard des Bouvets F-92741 NanterreCedex Phone: +33 (0)1 / 55 68 55 68 Fax: +33 (0)1 / 55 68 57 57

BOSNIA AND HERZEGOVINA INEA BH d.o.o. Aleja Lipa 56 BA-71000 Sarajevo Phone: +387 (0)33 / 921 164 Fax: +387 (0)33/ 524 539

NORWAY Beijer Electronics AS Postboks 487 NO-3002 Drammen Phone: +47 (0)32 / 24 30 00 Fax: +47 (0)32 / 84 85 77

ISRAEL TEXEL ELECTRONICS Ltd. 2 Ha´umanut, P.O.B. 6272 IL-42160 Netanya Phone: +972 (0)9 / 863 39 80 Fax: +972 (0)9 / 885 24 30

IRELAND MITSUBISHI ELECTRIC EUROPE B.V. Irish Branch Westgate Business Park, Ballymount IRL-Dublin 24 Phone: +353 (0)1 4198800 Fax: +353 (0)1 4198890

LEBANON CEG INTERNATIONAL Cebaco Center/Block A Autostrade DORA Lebanon - Beirut Phone: +961 (0)1 / 240 430 Fax: +961 (0)1 / 240 438

BULGARIA AKHNATON 4 Andrej Ljapchev Blvd. Pb 21 BG-1756 Sofia Phone: +359 (0)2 / 817 6004 Fax: +359 (0)2 / 97 44 06 1

POLAND MPL Technology Sp. z o.o. Ul. Krakowska 50 PL-32-083 Balice Phone: +48 (0)12 / 630 47 00 Fax: +48 (0)12 / 630 47 01

ITALY MITSUBISHI ELECTRIC EUROPE B.V. Italian Branch Viale Colleoni 7 I-20041 Agrate Brianza (MI) Phone: +39 039 / 60 53 1 Fax: +39 039 / 60 53 312

CROATIA INEA CR d.o.o. Losinjska 4 a HR-10000 Zagreb Phone:+385(0)1/36940-01/-02/-03 Fax: +385 (0)1 / 36 940 - 03

ROMANIA Sirius Trading & Services srl Aleea Lacul Morii Nr. 3 RO-060841 Bucuresti, Sector 6 Phone: +40 (0)21 / 430 40 06 Fax: +40 (0)21 / 430 40 02

AFRICAN REPRESENTATIVE

SOUTH AFRICA CBI Ltd. Private Bag 2016 ZA-1600 Isando Phone: + 27 (0)11 / 928 2000 Fax: + 27 (0)11 / 392 2354

SPAIN MITSUBISHI ELECTRIC EUROPE B.V. Spanish Branch Carretera de Rubí 76-80 E-08190 Sant Cugat del Vallés (Barcelona) Phone: 902 131121 // +34 935653131 Fax: +34 935891579

CZECH REPUBLIC AutoCont C.S. s.r.o. Technologická 374/6 CZ-708 00 Ostrava-Pustkovec Phone: +420 595 691 150 Fax: +420 595 691 199

SERBIA Craft Con. & Engineering d.o.o. Bulevar Svetog Cara Konstantina 80-86 SER-18106 Nis Phone:+381 (0)18 / 292-24-4/5 Fax: +381 (0)18 / 292-24-4/5

UK MITSUBISHI ELECTRIC EUROPE B.V. UK Branch Travellers Lane UK-Hatfield, Herts. AL10 8XB Phone: +44 (0)1707 / 27 61 00 Fax: +44 (0)1707 / 27 86 95

CZECH REPUBLIC B:TECH A.S. U Borové 69 CZ-58001 Havlíčkův Brod Phone: +420 (0)569 777 777 Fax: +420 (0)569-777 778

SERBIA INEA SR d.o.o. Izletnicka 10 SER-113000 Smederevo Phone: +381 (0)26 / 617 163 Fax: +381 (0)26 / 617 163

DENMARK Beijer Electronics A/S Lykkegårdsvej 17, 1. DK-4000 Roskilde Phone: +45 (0)46/ 75 76 66 Fax: +45 (0)46 / 75 56 26

SLOVAKIA AutoCont Control s.r.o. Radlinského 47 SK-02601 Dolny Kubin Phone: +421 (0)43 / 5868210 Fax: +421 (0)43 / 5868210

JAPAN MITSUBISHI ELECTRIC CORPORATION Office Tower “Z” 14 F 8-12,1 chome, Harumi Chuo-Ku Tokyo 104-6212 Phone: +81 3 622 160 60 Fax: +81 3 622 160 75

ESTONIA Beijer Electronics Eesti OÜ Pärnu mnt.160i EE-11317 Tallinn Phone: +372 (0)6 / 51 81 40 Fax: +372 (0)6 / 51 81 49

SLOVAKIA CS MTrade Slovensko, s.r.o. Vajanskeho 58 SK-92101 Piestany Phone: +421 (0)33 / 7742 760 Fax: +421 (0)33 / 7735 144

USA MITSUBISHI ELECTRIC AUTOMATION, Inc. 500 Corporate Woods Parkway Vernon Hills, IL 60061 Phone: +1 847 478 21 00 Fax: +1 847 478 22 53

FINLAND Beijer Electronics OY Jaakonkatu 2 FIN-01620 Vantaa Phone: +358 (0)207 / 463 500 Fax: +358 (0)207 / 463 501

SLOVENIA INEA d.o.o. Stegne 11 SI-1000 Ljubljana Phone: +386 (0)1 / 513 8100 Fax: +386 (0)1 / 513 8170

GREECE UTECO A.B.E.E. 5, Mavrogenous Str. GR-18542 Piraeus Phone: +30 211 / 1206 900 Fax: +30 211 / 1206 999

SWEDEN Beijer Electronics AB Box 426 SE-20124 Malmö Phone: +46 (0)40 / 35 86 00 Fax: +46 (0)40 / 35 86 02

HUNGARY MELTRADE Ltd. Fertő utca 14. HU-1107 Budapest Phone: +36 (0)1 / 431-9726 Fax: +36 (0)1 / 431-9727

SWITZERLAND Econotec AG Hinterdorfstr. 12 CH-8309 Nürensdorf Phone: +41 (0)44 / 838 48 11 Fax: +41 (0)44 / 838 48 12

LATVIA Beijer Electronics SIA Vestienas iela 2 LV-1035 Riga Phone: +371 (0)784 / 2280 Fax: +371 (0)784 / 2281

TURKEY GTS Darülaceze Cad. No. 43 KAT. 2 TR-34384 Okmeydanı-Istanbul Phone: +90 (0)212 / 320 1640 Fax: +90 (0)212 / 320 1649

LITHUANIA Beijer Electronics UAB Savanoriu Pr. 187 LT-02300 Vilnius Phone: +370 (0)5 / 232 3101 Fax: +370 (0)5 / 232 2980

UKRAINE CSC Automation Ltd. 4-B, M. Raskovoyi St. UA-02660 Kiev Phone: +380 (0)44 / 494 33 55 Fax: +380 (0)44 / 494-33-66

MITSUBISHI ELECTRIC FACTORY AUTOMATION

Mitsubishi Electric Europe B.V. /// FA - European Business Group /// Gothaer Straße 8 /// D-40880 Ratingen /// Germany Tel.: +49(0)2102-4860/// Fax: +49(0)2102-4861120/// info@mitsubishi-automation.com /// www.mitsubishi-automation.com

Display codes

Error codes

What the fault codes shown on the display mean and how to clear them.

CodeMeaningFix
SD500b0 to b15 (Axis 1 to 16) p.144
SD501b0 to b15 (Axis 17 to 32) p.144
SD502b0 to b15 (Axis 1 to 16) p.144
SD503b0 to b15 (Axis 17 to 32) p.144
SD510b0 to b15 (Axis 1 to Axis 16) p.144
SD511b0 to b15 (Axis 17 to Axis 32) p.144
SD513The manual pulse generator axis setting error is stored in b0 to b2 p.144
SD514One pulse input magnification setting error is stored in b0 to b15 p.144
SD515One pulse input magnification setting error is stored in b0 to b15 p.144
M9255and special registers (D9000 to D9255) are automatically converted into new p.146
ROM ERROR1• Type of the operating system software of data written to ROM is different. p.148
ROM ERROR2• Data is not written to ROM. p.148
1000Runaway or failure of CPU module. (1) Malfunctioning due to noise or other reason (2) Hardware fault(1) Take noise reduction measures. (2) Reset the CPU module and RUN it again. If the same error is displayed again, this suggests a CPU module hardware fault. Explain the error symptom and get advice from our sales representative. p.152
1105The CPU shared memory in the CPU module is faulty. p.152
1150The memory of the CPU module in the Multiple CPU high speed transmission area is faulty. p.152
1300There is an output module with a blown fuse.Check FUSE. LED of the output modules and replace the module whose LED is lit. p.152
1401There was no response from the Motion module/intelligent function module in the initial processing.Set the Motion module/intelligent function module used in the Motion CPU in the system setting. This suggests a Motion module, intelligent function module, CPU module and/or base unit is expecting a hardware fault. Explain the error symptom and get advice from our sales representative. p.152
1403(1) An error is detected at the intelligent function module. (2) The I/O module (including intelligent function module) is nearly removed or completely removed/mounted during running.The CPU module, base unit and/or the intelligent function module that was accessed is experiencing a hardware fault. Explain the error symptom and get advice from our sales representative. p.152
1413An error is detected on the system bus.Reset the CPU module and RUN it again. If the same error is displayed again, the intelligent function module, CPU module or base unit is faulty. Explain the error symptom and get advice from our sales representative. p.152
1415Fault of the main or extension base unit was detected. p.152
1416System bus fault was detected at power-on or reset. p.152
1430The error of self CPU is detected in the Multiple CPU high speed bus.Reset the CPU module and RUN it again. If the same error is displayed again, this suggests a CPU module hardware fault. Explain the error symptom and get advice from our sales representative. p.154
1431The communication error with other CPU is detected in the Multiple CPU high speed bus.(1) Take noise reduction measures. (2) Check the main base unit mounting status of the CPU module. (3) Reset the CPU module and RUN it again. If the same error is displayed again, this suggests a CPU module or base unit hardware fault. Explain the error symptom and get advice from our sales representative. p.154
1432The communication time out with other CPU is detected in the Multiple CPU high speed bus.Reset the CPU module and RUN it again. If the same error is displayed again, this suggests a CPU module hardware fault. Explain the error symptom and get advice from our sales representative. p.154
1433The communication error with other CPU is detected in the Multiple CPU high speed bus.(1) Take noise reduction measures. (2) Check the main base unit mounting status of the CPU module. (3) Reset the CPU module and RUN it again. If the same error is displayed again, this suggests a CPU module or base unit hardware fault. Explain the error symptom and get advice from our sales representative. p.154
1500A momentary power supply interruption has occurred. The power supply went off.Check the power supply. p.154
1600(1) The battery voltage in the CPU module has dropped below stipulated level. (2) The battery holder unit that install the battery is not mounted to the CPU module.(1) Change the battery. (2) Mount the battery holder unit that installs the battery. p.154
2100In the I/O assignment setting of PLC CPU, the intelligent function module was allocated to an I/O module or vice versa.Make the PLC parameter's I/O assignment setting again so it is consistent with the actual status of the intelligent function module and the CPU module. p.154
2107The first I/O No. set in the system settings is overlapped with the one for another module.Make the I/O No. setting again so it is consistent with the actual status of the modules. p.154
2140The motion modules (Q172DLX, Q172DEX, Q173DPX, Q172LX, Q172EX (-S1/-S2/-S3), Q173PX (-S1)) are installed in CPU slot or I/O 0 to 2 slot.Remove the Motion modules installed CPU slot or I/O 0 to 2 slot. p.154
2150In a Multiple CPU system, the control CPU of intelligent function module incompatible with the Multiple CPU system is set to other than CPU No.1.(1) Change to the intelligent function module (function version B or later) compatible with the Multiple CPU system. (2) Change the control CPU of intelligent function module incompatible with the Multiple CPU system to CPU No.1. p.154
3001The parameter settings are corrupted.(1) Check the parameter item corresponding the numerical value (parameter No.), and correct it. (2) Rewrite corrected parameters to the CPU module, reload or reset the Multiple CPU system power supply. (3) If the same error occurs, it is thought to be a hardware error. Explain the error symptom and get advice from our sales representative. p.156
3012Multiple CPU setting of Multiple CPU setting parameter or control CPU setting of system setting differs from that of the reference CPU settings.Match the Multiple CPU setting of Multiple CPU setting parameter or control CPU setting of system setting with that of the reference CPU (CPU No.1) settings. p.156
3013Multiple CPU automatic refresh setting is any of the following. (1) When a bit device is specified as a refresh device, a number other than a multiple of 16 is specified for the refresh start device. (2) The device specified is other than the one that may be specified. (3) The number of send points is an odd number. (4) The total number of send points is greater than the maximum number of refresh points.Check the following in the Multiple CPU automatic refresh setting and make correction. (1) When specifying the bit device, specify a multiple of 16 for the refresh start device. (2) Specify the device that may be specified for the refresh device. (3) Set the number of send points to an even number. (4) Set the total number of send points is within the range of the maximum number of refresh points. p.156
3015(1) "Use multiple CPU high speed transmission " is not set in the Multiple CPU setting of Universal module QCPU. (2) In a Multiple CPU system, the CPU verified is different from the one set in the parameter setting.(1) Set "Use multiple CPU high speed transmission " in the Universal module QCPU. (2) Check the parameter item corresponding to the numerical value (parameter No./CPU No.) and parameter of target CPU, and correct them. p.156
7000In the operating mode of a Multiple CPU system, a CPU error occurred at the CPU where "All station stop by stop error of CPU" was selected.Check the error of the CPU resulting in CPU module fault, and remove the errors. p.156
7002There is no response from the target CPU module in a Multiple CPU system during initial communication.Reset the CPU module and RUN it again. If the same error is displayed again, this suggests the hardware fault of any of the CPU modules. Explain the error symptom and get advice from our sales representative. p.156
7010In a Multiple CPU system, a faulty CPU module was mounted.Replace the faulty CPU module. p.156
7011Either of the following settings was made in a Multiple CPU system. (1) Multiple CPU automatic refresh setting was made for the inapplicable CPU module. (2) "I/O sharing when using multiple CPUs" setting was made for the inapplicable CPU module.(1) Correct the Multiple CPU automatic refresh setting. (2) Correct the "I/O sharing when using multiple CPUs" setting. p.156
7013(1) CPU module which cannot be mounted in OnCPU(H)CPU is mounted. (The module may break down.) (2) Q173HCPU,Q172HCPU,Q173CPUN,Q172CPUN is mounted.Remove Q173HCPU,Q172HCPU,Q173CPUN,Q172CPUN. p.156
7020In the operating mode of a Multiple CPU system, an error occurred in the CPU where "system stop" was not selected. (The CPU module where no error occurred was used to detect an error.)Check the error of the CPU resulting in CPU module fault, and remove the error. p.156
7030An assignment error occurred in the CPU-mountable slot (CPU slot, I/O slot 0 to 2) in excess of the number of CPU slot (with in the range of CPU number setting parameter).(1) Set the same value to the number of CPU modules specified in the Multiple CPU setting of the PLC parameter and the number of mounted CPU modules (including CPU (empty)). (2) Make the same as the state of the installation of CPU module set in the system setting. p.156
7031An assignment error occurred in the CPU slot (within the range of the CPU number setting parameter). p.156
7035The CPU module has been mounted on the inapplicable slot.Mount the CPU module on the applicable slot. p.156
10003Minor/major errors had occurred.Check the Motion error history of MT Developer and the minor/major error codes of minor/major error code of minor/major error code storage device, and remove the error cause. Refer to the error codes for error details of minor/major errors. p.158
10004Minor/major errors had occurred in virtual servomotor axis. (SV22) p.158
10005Minor/major errors had occurred in synchronous encoder axis. (SV22) p.158
10006The servo errors had occurred in the servo amplifier connected to the Motion CPU.Check the Motion error history of MT Developer and the servo error codes of servo error code storage device, and remove the error cause of servo amplifier. Refer to the servo error code for details of servo errors. p.158
10007Servo program setting error occurred.Check the Motion error history of MT Developer and the servo program setting error storage device (error program No., error item information), and remove the error cause. Refer to the servo program setting error codes for details of servo program setting errors. p.158
10008Real mode/virtual mode switching error occurred. (SV22)Check the Motion error history of MT Developer and the real mode/virtual mode switching error storage device, and remove the error cause. Refer to the real mode/virtual mode switching error codes for details of real mode/virtual mode switching errors. p.158
10009Manual pulse generator axis setting error occurred.Check the Motion error history of MT Developer and the manual pulse generator axis setting error storage device, and remove the error cause. Refer to the manual pulse generator axis setting error codes for details of manual pulse generator axis setting errors. p.158
10010Test mode request error occurred.Check the Motion error history of MT Developer and the test mode request error storage device, and remove the error cause. p.158
10011WDT error occurred at Motion CPU.Check the Motion error history of MT Developer and the Motion CPU WDT error factors, and remove the error cause. p.158
10014System setting error occurred at Motion CPU.Check the error message on error monitor screen of MT Developer, and remove the error cause. And then, turn on the power supply again or reset the Multiple CPU system. p.158
10016Motion slot fault occurred at Motion CPU. p.158
10020Motion SFC error occurred at Motion SFC program.Check the Motion error history of MT Developer, and remove the error cause. Refer to the Motion SFC error code for details of errors. p.158
10030Motion CPU internal bus error occurred.Motion CPU module hardware fault. Explain the error symptom and get advice from our sales representative. p.158

Ask about the Mitsubishi Electronics Q172DCPU

Owners and our team usually reply within a day — and your question helps the next person too.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
No questions yet about the Mitsubishi Electronics Q172DCPU

Be the first to ask — other owners or our team will answer.

Original document

Mitsubishi Electronics Q172DCPU manual PDF

174 pages·1.7 MB·Home Security System·PDF
Click any page above to open it here
Page 1 / …
100%
Loading pages…