EN
Mitsubishi Electronics logo
Official user manual

Mitsubishi Electronics MXZ-4A80VA

12 pages·560 KB·Air Conditioner·PDF·ENDEFRITNLJA
Mitsubishi Electronics MXZ-4A80VA
Table of Contents 54 sections SPLIT-TYPE AIR CONDITIONER · CONTENTS · 1. THE FOLLOWING SHOULD ALWAYS BE OBSERVED FOR · INSTALLATION MANUAL · … ShowHide
SPLIT-TYPE AIR CONDITIONERp.1CONTENTSp.11. THE FOLLOWING SHOULD ALWAYS BE OBSERVED FORp.1INSTALLATION MANUALp.12. INSTALLATION DIAGRAM & ACCESSORIES ................................ 2p.1Model MXZ-4A80VA HFC utilized R410Ap.13. SELECTING THE INSTALLATION LOCATION................................ 3p.14. OUTDOOR UNIT INSTALLATION ................................................... 4p.15. INDOOR/OUTDOOR UNITS CONNECTION FINISHING ANDp.1IMPORTANT NOTESp.1TO COMPLY WITH THE REQUIREMENTS OF AUSTRALIANp.1STANDARD AS 3000 S.A.A. WIRING RULES, THE ELECTRICALp.1WIRING REQUIRED BETWEEN THE INDOOR AND OUTDOORp.1UNITS MUST BE INSTALLED BY A LICENCED ELECTRICAL CON-p.1FOR INSTALLERp.1Before installationp.2WARNINGp.2CAUTIONp.23. SELECTING THE INSTALLATION LOCATIONp.3Constraints On Indoor Unit Installationp.34. OUTDOOR UNIT INSTALLATIONp.44-1 INSTALLING THE UNITp.4FREE SPACE REQUIRED AROUND OUTDOOR UNIT (Unit: mm)p.44-2 MOUNTING ARRANGEMENT OF DRAIN SOCKETp.44-3 HOW TO REMOVE THE SERVICE PANEL AND THE CONNECT COVERp.4Î UNIT GASp.5Å UNIT GASp.54-4 INDOOR/OUTDOOR WIRE CONNECTION AND OUTDOOR POWER SUPPLY CORD CONNECTIONp.5UNIT UNIT UNIT UNITp.55. INDOOR/OUTDOOR UNITS CONNECTION FINISHING AND TEST RUNp.65-1 FLARED CONNECTIONSp.6PIPE LENGTH AND HEIGHT DIFFERENCEp.6PIPING PREPARATIONp.6(MXZ-4A80VA)p.6SELECTING PIPE SIZEp.65-2 FLARING WORKp.61. Pipe cuttingp.62. Burrs removalp.63. Putting nut onp.64. Flaring workp.7PURGING PROCEDURESp.75. Checkp.75-3 PIPE CONNECTIONp.7INSULATION AND TAPINGp.75-7 LOWERING THE OPERATING NOISE OF THE OUTDOOR UNITp.85-5 EARTHING WORKp.8[How to lower the operating noise]p.85-8 CHECKING AFTER INSTALLATIONp.85-6 LOCKING THE OPERATION MODE OF THE AIR CONDITIONER (COOL, DRY, HEAT)p.8[How to lock the operation mode]p.85-9 GAS CHARGEp.95-10 TEST RUNp.95-11 EXPLANATION TO THE CUSTOMERp.9SG79Y674H01p.12
Page 1 of the Mitsubishi Electronics MXZ-4A80VA user manual — Table of Contents
Page 1 · Contents
Contents

Contents

SPLIT-TYPE AIR CONDITIONERp.1CONTENTSp.11. THE FOLLOWING SHOULD ALWAYS BE OBSERVED FORp.1INSTALLATION MANUALp.12. INSTALLATION DIAGRAM & ACCESSORIES ................................ 2p.1Model MXZ-4A80VA HFC utilized R410Ap.13. SELECTING THE INSTALLATION LOCATION................................ 3p.14. OUTDOOR UNIT INSTALLATION ................................................... 4p.15. INDOOR/OUTDOOR UNITS CONNECTION FINISHING ANDp.1IMPORTANT NOTESp.1TO COMPLY WITH THE REQUIREMENTS OF AUSTRALIANp.1STANDARD AS 3000 S.A.A. WIRING RULES, THE ELECTRICALp.1WIRING REQUIRED BETWEEN THE INDOOR AND OUTDOORp.1UNITS MUST BE INSTALLED BY A LICENCED ELECTRICAL CON-p.1FOR INSTALLERp.1Before installationp.2WARNINGp.2CAUTIONp.23. SELECTING THE INSTALLATION LOCATIONp.3Constraints On Indoor Unit Installationp.34. OUTDOOR UNIT INSTALLATIONp.44-1 INSTALLING THE UNITp.4FREE SPACE REQUIRED AROUND OUTDOOR UNIT (Unit: mm)p.44-2 MOUNTING ARRANGEMENT OF DRAIN SOCKETp.44-3 HOW TO REMOVE THE SERVICE PANEL AND THE CONNECT COVERp.4Î UNIT GASp.5Å UNIT GASp.54-4 INDOOR/OUTDOOR WIRE CONNECTION AND OUTDOOR POWER SUPPLY CORD CONNECTIONp.5UNIT UNIT UNIT UNITp.55. INDOOR/OUTDOOR UNITS CONNECTION FINISHING AND TEST RUNp.65-1 FLARED CONNECTIONSp.6PIPE LENGTH AND HEIGHT DIFFERENCEp.6PIPING PREPARATIONp.6(MXZ-4A80VA)p.6SELECTING PIPE SIZEp.65-2 FLARING WORKp.61. Pipe cuttingp.62. Burrs removalp.63. Putting nut onp.64. Flaring workp.7PURGING PROCEDURESp.75. Checkp.75-3 PIPE CONNECTIONp.7INSULATION AND TAPINGp.75-7 LOWERING THE OPERATING NOISE OF THE OUTDOOR UNITp.85-5 EARTHING WORKp.8[How to lower the operating noise]p.85-8 CHECKING AFTER INSTALLATIONp.85-6 LOCKING THE OPERATION MODE OF THE AIR CONDITIONER (COOL, DRY, HEAT)p.8[How to lock the operation mode]p.85-9 GAS CHARGEp.95-10 TEST RUNp.95-11 EXPLANATION TO THE CUSTOMERp.9SG79Y674H01p.12
Page 2 of the Mitsubishi Electronics MXZ-4A80VA user manual — F
Page 2 · click to enlarge
Page 2
2. INSTALLATION DIAGRAM & ACCESSORIES 1. THE FOLLOWING SHOULD ALWAYS BE OBSERVED FOR SAFETY
  • Be sure to read “THE FOLLOWING SHOULD ALWAYS BE OBSERVED FOR SAFETY” before installing the air conditioner.
  • Be sure to observe the cautions specified here as they include important items related to safety.
  • The indications and meanings are as follows. WARNING: Could lead to death, serious injury, etc. CAUTION: Could lead to serious injury in particular environments when operated incorrectly.
  • After reading this manual, be sure to keep it together with the OPERATING INSTRUCTIONS in a handy place on the customer’s site.

Before installation

This installation manual is only for the outdoor unit installation. In installing the indoor units, refer to the installation manual attached to each indoor unit. Any structural alternations necessary for the installation must comply with the local building code require- ments.

WARNING

I Do not install the unit by yourself (customer).

I Perform electrical work according to the in-

Incomplete installation could cause injury due to fire, electric shock, the unit falling or leakage of water. Consult the dealer from whom you pur- chased the unit or special installer. I Install the unit securely in a place which can

stallation manual and be sure to use an ex- clusive circuit. If the capacity of the power circuit is insufficient or there is insufficient electrical work, it could re- sult in a fire or an electric shock. I Attach the electrical cover to the indoor unit

D

K

bear the weight of the unit. When installed in an insufficient strong place, the unit could fall causing injury. I Use the specified wires to connect the indoor

and the service panel to the outdoor unit se- curely. If the electrical cover in the indoor unit and/or the service panel in the outdoor unit are not attached securely, it could result in a fire or an electric shock due to dust water, etc. I Be sure to use the part provided or specified

H

and outdoor units securely and attach the wires firmly to the terminal block connecting sections so the stress of the wires is not ap- plied to the sections. Incomplete connecting and fixing could cause fire. I Do not use intermediate connection of the

parts for the installation work. The use of defective parts could cause an injury due to a fire, an electric shock, the unit falling, leakage of water, etc. I Be sure to cut off the main power in case of

power cord or the extension cord and do not connect many devices to one AC outlet. It could cause a fire or an electric shock due to defective contact, defective insulation, exceed- ing the permissible current, etc. I Check that the refrigerant gas due not leak

E

Open as a rule More than 500 mm if the front and both sides are open

J

setting up the indoor electronic control P.C. board or wiring works. It could cause an electric shock. I The appliance shall be installed in accordance

after installation has completed. If refrigerant gas leaks indoors, and comes into contact with the fire of a fan heater, space heater, stove, etc., harmful substances will be generated. I Perform the installation securely referring to

with national wiring regulations. I When installing or relocating the unit, make

More than 100 mm More than 200 mm if there are obstacles to both sides

sure that no substance other than the speci- fied refrigerant (R410A) enters the refrigerant circuit. Any presence of foreign substance such as air can cause abnormal pressure rise or an explo- sion.

the installation manual. Incomplete installation could cause a personal injury due to fire, electric shock, the unit falling or leakage of water.

More than 100 mm

F

CAUTION

I Perform earthing.

I Install an earth leakage breaker depending on

Do not connect the earth wire to a gas pipe, wa- ter pipe, lightning rod or telephone earth wire. Defective earthing could cause an electric shock. I Do not install the unit in a place where an in-

the installation place (Where it is humid). If a earth leakage breaker is not installed, it could cause an electric shock. I Perform the drainage/piping work securely

Open as a rule More than 500 mm if the back, both sides and top are open More than 350 mm

flammable gas leaks. If gas leak and accumulate in the area surround- ing the unit, it could cause an explosion. I Fasten a flare nut with a torque wrench as

according to the installation manual. If there is a defect in the drainage/piping work, water could drop from the unit and household goods could be wet and damaged.

specified in this manual. When fastened too tight, a flare nut may broken after a long period and cause a leakage of refrig- erant.

Page 3 of the Mitsubishi Electronics MXZ-4A80VA user manual — Constraints On Indoor Unit Installation
Page 3 · click to enlarge
Page 3

3. SELECTING THE INSTALLATION LOCATION

Parts to be locally procured

  • Where it is not exposed to strong wind.
  • Where airflow is good and dustless.
  • Where it is not exposed to rain and direct sunshine.
  • Where neighbours are not annoyed by operation sound or hot air.
  • Where rigid wall or support is available to prevent the increase of operation sound or vibration.
  • Where there is no risk of combustible gas leakage.
  • When installing the unit at a high level, be sure to fix the unit legs.
  • Where it is at least 3 m away from the antenna of TV set or radio. Operation of the air conditioner may interfere with radio or TV reception in areas where reception is weak. An amplifier may be required for the affected device.
  • Install the unit horizontally.
  • Please install it in an area not affected by snowfall or blowing snow. In areas with heavy snow, please install a canopy, a pedestal and/or some baffle boards.
APower supply cord (3-core 2.5 mm2)1 BIndoor/outdoor unit connecting wire (4-core 1.0 mm2/1.5 mm2)1 CExtension pipe According to “Selecting pipe size”1 DWall hole cover1 EPiping tape1 FExtension drain hose (or soft vinyl chloride hose of 15 mm in internal dia. or hard vinyl chloride pipe VP16)1 GRefrigeration oilLittle amount HPutty1 IPipe fixing band (The number depends on the pipe length.)2 to 7 JFixing screw for I (The number depends on the pipe length.)2 to 7 KWall hole sleeve1 LSoft vinyl chloride hose of 25 mm in internal dia. or hard vinyl chloride pipe VP251
  • CAUTION: Avoid the following places for installation where air conditioner trouble is liable to occur.
  • Where flammable gas could leak.
  • Where there is much machine oil.
  • Salty places such as the seaside.
  • Where sulfide gas is generated such as a hot spring.
  • Where there is high-frequency or wireless equipment.
  • The “Q’ty” for B to K in the above table is the quantity to be used per indoor unit. WARNING: Be sure to use specified accessories and supplied parts for installation work. If there is some deficiency in parts, it may cause a risk of fire, electric shock, injury by a unit fall or water leakage.

2-U-shape notched holes (Base bolt M10)

Constraints On Indoor Unit Installation

2-12 × 36 Oval holes (Base bolt M10) (Unit: mm)

You should note that indoor unit that can be connected to this outdoor unit have the following constraints on them. • Indoor units with model numbers 22, 25, 35, 50, 60 and 71 can be connected. Refer to the table below for possible two-room, three-room and four-room indoor unit combinations.

  • Note: When operating the air conditioner in low outside temperature, be sure to follow the instructions described below.
  • Never install the outdoor unit in a place where its air inlet/outlet side may be exposed directly to wind.
  • To prevent exposure to wind, install the outdoor unit with its air inlet side facing the wall.
  • To prevent exposure to wind, it is recommended to install a baffle board on the air outlet side of the outdoor unit.
2 UNIT22+2222+2522+3522+5022+6022+7125+25 25+3525+5025+6025+7135+3535+5035+60 35+7150+5050+6050+7160+6060+71 3 UNIT22+22+2222+22+2522+22+3522+22+5022+22+6022+22+7122+25+25 22+25+3522+25+5022+25+6022+25+7122+35+3522+35+5022+35+60 22+35+7122+50+5022+50+6022+50+7125+25+2525+25+3525+25+50 25+25+6025+25+7125+35+3525+35+5025+35+6025+35+7125+50+50 25+50+6035+35+3535+35+5035+35+6035+35+7135+50+5035+50+60 4 UNIT22+22+22+2222+22+22+2522+22+22+3522+22+22+5022+22+22+6022+22+22+7122+22+25+25 22+22+25+3522+22+25+5022+22+25+6022+22+25+7122+22+35+3522+22+35+5022+22+35+60 22+22+50+5022+25+25+2522+25+25+3522+25+25+5022+25+25+6022+25+35+3522+25+35+50 22+25+35+6022+35+35+3522+35+35+5025+25+25+2525+25+25+3525+25+25+5025+25+25+60 25+25+35+3525+25+35+5025+35+35+3535+35+35+35

Air in · Air in · Air out

Page 4 of the Mitsubishi Electronics MXZ-4A80VA user manual — 4-3 HOW TO REMOVE THE SERVICE PANEL AND THE CONNECT COVER
Page 4 · click to enlarge
Page 4

4. OUTDOOR UNIT INSTALLATION

4-1 INSTALLING THE UNIT

FREE SPACE REQUIRED AROUND OUTDOOR UNIT (Unit: mm)

1. Top side obstacles When there is an obstacle behind the rear side only, it does not matter if there is an obstacle over the top side as shown in the figure below.
2. Front (blowing) side open As long as space like the one shown in the figure can be maintained, it does not matter if there are obstacles in three directions (but top side is open).
  • Be sure to fix the unit’s legs with bolts when installing it.
  • Be sure to install the unit firmly to ensure that it does not fall by an earthquake or a gust.
  • Refer to the figure in the right for concrete foundation.
Mitsubishi Electronics MXZ-4A80VA — FREE SPACE REQUIRED AROUND OUTDOOR UNIT (Unit: mm) diagram (page 4)
Fig. 1 · FREE SPACE REQUIRED AROUND OUTDOOR UNIT (Unit: mm)

100 or more 200 or more

Mitsubishi Electronics MXZ-4A80VA — FREE SPACE REQUIRED AROUND OUTDOOR UNIT (Unit: mm) diagram (page 4)
Fig. 2 · FREE SPACE REQUIRED AROUND OUTDOOR UNIT (Unit: mm)

Fix here with M10 bolts.

350 or more 100 or more

3. Obstacles on front (blowing) side only In this case, the rear, both sides and top should be open.
4. Obstacles on front and rear side only The unit can be used by attaching an optional outdoor blowing guide (MAC-855SG) (but both sides and top are open).

Make the setting depth deeper.

Make with wider.

  • Do not use the drain socket and the drain cap in the cold region. Drain may freeze and it makes the fan stop.
Mitsubishi Electronics MXZ-4A80VA — FREE SPACE REQUIRED AROUND OUTDOOR UNIT (Unit: mm) diagram (page 4)
Fig. 3 · FREE SPACE REQUIRED AROUND OUTDOOR UNIT (Unit: mm)

25 mm or less

Anchor both length Anchor both pitch

(Unitmm)
5. Service space Keep the service space as shown in the figure below for maintenance.

4-2 MOUNTING ARRANGEMENT OF DRAIN SOCKET

Please perform the drain piping work only when draining from one place.

350 or more 500 or more

1Please choose one hole to discharge drain and install the drain socket to the hole. 2Please close the rest of the holes with the drain caps. 3Please connect a vinyl hose of 25 mm in the inside diameter on the market with the drain socket and lead drain.

4-3 HOW TO REMOVE THE SERVICE PANEL AND THE CONNECT COVER

  • Remove the four service panel securing screws, and pull the panel down in an arrow direction to remove the service panel.
  • Remove the four connect cover securing screws to remove the connect cover.
Show 14 more labels / short text on this page
500 or more · Anchor leg · · 100 or more · 500 or more · · 500 or more · Blowing guide (MAC-855SG) · Service space · 100 or more · 500 or more · 100 or more · Connect cover · Service panel
Page 5 of the Mitsubishi Electronics MXZ-4A80VA user manual — UNIT UNIT UNIT UNIT
Page 5 · click to enlarge
Page 5

  • For the power supply cord and the indoor/outdoor unit connecting wires, be sure to use the ones in compliance with the standards.
  • Be sure to push the core until it is hidden and pull each cable to make sure that it is not pulled up. Incomplete insertion may cause a risk of burning the terminal blocks.

Power cable terminal block

Indoor/Outdoor connecting terminal block

Power supply cord Specification Cable 3-core 2.5 mm2, in conformity with Design 245 IEC 57. Indoor and Outdoor connecting wire Specification Cable 4-core 1.0/1.5 mm2, in conformity with Design 245 IEC 57.

Opening for power cable and indoor/out- door connecting wire

This installation manual is only for the outdoor unit installation. In installing the indoor units, refer to the installation manual attached to each indoor unit.

Î UNIT GAS

Liquid Ç UNIT GAS

Indoor/outdoor unit connecting wire

Liquid ı UNIT GAS

Å UNIT GAS

4-4 INDOOR/OUTDOOR WIRE CONNECTION AND OUTDOOR POWER SUPPLY CORD CONNECTION

  • Be sure to lead in the power supply cord A to the air conditioner in accordance with the specification table below and “Technical Standards for Electrical Installation”.
  • Be sure to use special circuits for room air conditioner.

POWER SUPPLY ~/N 230 V 50 Hz

UNIT

WARNING: Be sure to comply with “Technical Standards for Electrical Installation”, follow this manual and use special circuits for electrical work. If there is a lack of circuit capacity or some deficiency in installation, it may cause a risk of fire or electric shock. Overcurrent that might be produced may include DC substances. Be careful to choose the correct type of overcurrent protection switch.

Power supply cord A

  • Give extra length to both power supply cord A and indoor/outdoor unit connecting wire B taking later service into account.
  • After making connections between both power supply cord A and indoor/outdoor unit connecting wire B , be sure to fix both cable and wire with cable clamps.

Rated Voltage Breaker capacity 230 V 25 A

Connect to the supply terminals and leave a contact separation of at least 3 mm at each pole to disconnect the source power pole. (When the power switch is shut off, it must disconnect all poles.)

  • Peel off both ends of the cables as shown in the right.
  • Take care not to let the cables contact the pipes inside the unit.
  • Take enough care to connect the indoor/outdoor unit connecting wire correctly between the respective indoor units and the outdoor unit.
  • Make earth wire a little longer than the others. (more than 35 mm)

Indoor/Outdoor unit connecting wire B

Show 6 more labels / short text on this page
Liquid · Connection pipe connections · Liquid · Cable clamp · 15 mm · 35 mm
Page 6 of the Mitsubishi Electronics MXZ-4A80VA user manual — 3. Putting nut on
Page 6 · click to enlarge
Page 6

5. INDOOR/OUTDOOR UNITS CONNECTION FINISHING AND TEST RUN

5-1 FLARED CONNECTIONS

  • * Connections at outdoor unit are described as unit A, B, C and D below corresponding to the indication on each valve.
  • If the diameter of connection pipes does not match the diameter of pipe end connections, use optional different-diameter joints.
  • When connecting the model 50 to either unit B, C or D, use optional different-diameter joints MAC-A454JP because the valve size of gas pipes for the outdoor unit is ø9.52 mm.
  • When connecting the model 22, 25 or 35 to unit A, use optional different-diameter joints MAC-A455JP because the valve size of gas pipes for the outdoor unit is ø12.7 mm.
  • When connecting the model 60 to unit A, use optional different-diameter joints MAC-A456JP because the valve size of gas pipes for the outdoor unit is ø12.7 mm.
  • When connecting the model 60 to either unit B, C or D, use optional different-diameter joints PAC-SG76RJ because the valve size of gas pipes for the outdoor unit is ø9.52 mm.
  • When connecting the model 71 to unit A, use optional different-diameter joints MAC-A456JP and PAC-493PI because the valve size of gas pipe and liquid pipe for the outdoor unit is ø12.7 mm and ø6.35 mm.
  • When connecting the model 71 to either unit B, C or D, use optional different-diameter joints PAC-SG76RJ and PAC-493PI because the valve size of gas pipe and liquid pipe for the outdoor unit is ø9.52 mm and ø6.35 mm.

PIPE LENGTH AND HEIGHT DIFFERENCE

Limits4A80VA Pipe length per indoor unit25 m max. Total pipe length for multi-system70 m max. Height difference10 m max. No. of bends per indoor unit25 max. Total No. of bends for multi-system70 max.

Refrigerant adjustment If pipe length exceeds 40 m, additional refrigerant (R410A) charge is required. (The outdoor unit is charged with refrigerant for total pipe length up to 40 m.)

Pipe lengthUp to 40 mNo additional charge is required. Exceeding 40 mAdditional charge is required. (Refer to the table below.) Refrigerant to be added20 g/m × (refrigerant piping length(m)-40)

PIPING PREPARATION

Indoor unitÎ UNIT Ç UNIT Outdoor unit ı UNIT Å Indoor unit Indoor unit

1If you use commercially available copper pipes, use the following table for pipe specifications.

Outside diameter Wall thickness Liquid pipe ø6.35 mm 0.8 mm Gas pipe ø9.52 mm 0.8 mm Gas pipe ø12.7 mm 1.0 mm Gas pipe ø15.88 mm 1.0 mm

(MXZ-4A80VA)

2For insulation material, use 8 mm-thick heat-insulating expended polyethylene with a specific gravity of 0.045. 3Ensure that the 2 refrigerant pipes are insulated to prevent condensation. 4Refrigerant pipe bending radius must be 100 mm or more.

  • For pipe size, see the table below.

SELECTING PIPE SIZE

The diameter of connection pipes differs according to the type and capacity of indoor units. Match the diameters of connection pipes for indoor and outdoor units according to the following table.

Model namePipe size for indoor unitAllowable connection pipe size 22 25Liquid pipeø6.35 mmø6.35 mm Gas pipeø9.52 mmø9.52 mm 35Liquid pipeø6.35 mmø6.35 mm Gas pipeø9.52 mmø9.52 mm 50Liquid pipeø6.35 mmø6.35 mm Gas pipeø12.7 mmø12.7 mm 60Liquid pipeø6.35 mmø6.35 mm Gas pipeø15.88 mmø15.88 mm 71Liquid pipeø9.52 mmø9.52 mm Gas pipeø15.88 mmø15.88 mm
Valve size for outdoor unit Å UNITLiquid pipeø6.35 mm Gas pipeø12.7 mm ı UNITLiquid pipeø6.35 mm Gas pipeø9.52 mm Ç UNITLiquid pipeø6.35 mm Gas pipeø9.52 mm Î UNITLiquid pipeø6.35 mm Gas pipeø9.52 mm

5-2 FLARING WORK

  • Main cause of gas leakage is defect in flaring work. Perform flaring work correctly in the following procedure.

1. Pipe cutting

  • Cut the copper pipe correctly with pipe cutter.

2. Burrs removal

  • Completely remove all burrs from the cut cross section of the pipe.
  • Put the end of the copper pipe downward to prevent burrs from dropping in the pipe.

3. Putting nut on

  • Remove flare nuts attached to indoor and outdoor units, then put them on pipe having completed burr removal. (not possible to put them on after flaring work)
  • Flare nut for R410A pipe may differ from R22 pipe depending on the diameter of pipe.
Show 10 more labels / short text on this page
No good · Good · Copper pipe · Tilted Uneven Burred · 90° · Burr Copper pipe · Spare reamer · Pipe cutter · Flare nut · Copper pipe
Page 7 of the Mitsubishi Electronics MXZ-4A80VA user manual — INSULATION AND TAPING
Page 7 · click to enlarge
Page 7
  • 5-4 PURGING PROCEDURES
  • LEAK TEST
  • Perform the manifold valve work securely according to the installation manual of the manifold valve.

4. Flaring work

  • Perform flaring work using flaring tool as shown in the right.
Outside diameterA (mm) Flare tool for R410A clutch typeConventional flare tool Clutch typeWing nut type ø6.35 mm0 to 0.51.0 to 1.51.5 to 2.0 ø9.52 mm0 to 0.51.0 to 1.51.5 to 2.0 ø12.7 mm ø15.88 mm0 to 0.5 0 to 0.51.0 to 1.5 1.0 to 1.52.0 to 2.5 —

PURGING PROCEDURES

Wing nut type Clutch type

Connect the refrigerant pipes (both liquid pipe and gas pipe) between the indoor and the outdoor unit.

A

Remove the service port cap of the stop valve on the gas pipe side of the outdoor unit. (The stop valve will not work in it initial state fresh out of the factory [totally closed with cap on].)

Firmly hold copper pipe in a die in the dimension shown in the table above.

Connect the gauge manifold valve and the vacuum pump to the service port of the stop valve on the gas pipe side of the outdoor unit.

5. Check

Inside is shining without any scratches

  • Compare the flared work with the figure below.
  • If flare is noted to be defective, cut off the flared section and perform flaring work again.

Run the vacuum pump. (Vacuumize for more than 15 minutes.)

Check the vacuum with the gauge manifold valve, then close the gauge manifold valve and stop the vacuum pump.

Even length all around

5-3 PIPE CONNECTION

Leave it as is for one or two minutes. Make sure the pointer of the gauge manifold valve remains in the same position. Confirm that the pressure gauge shows –0.101 MPa [Gauge] (–760 mmHg).

Compound pressure gauge (for R410A) -0.101MPa (-760 mmHg)

Pressure gauge (for R410A)

1. Indoor unit connection • Connect both liquid pipe and gas pipe to indoor unit. - Apply a thin coat of refrigeration oil to the seat surface of pipe. - For connection, align the center of both pipe and union, then tighten the first 3 to 4 turns in flare nut by

Stop valve (gas side)

Gauge manifold valve (for R410A)

Charge hose (for R410A)

hand. - For tightening the union part of the indoor unit side, use the table below as a standard and tighten

(or the vacuum pump with the function to prevent the back flow)

the flare nut with two wrenches. Excessive tightening damages the flared section.

Adapter for preventing the back flow

Pipe diameterTightening torque N·mkgf·cm ø6.35 mm13.7 to 17.7140 to 180 ø9.52 mm34.3 to 41.2350 to 420 ø12.7 mm49.0 to 56.4500 to 575 ø15.88 mm73.5 to 78.4750 to 800
Mitsubishi Electronics MXZ-4A80VA — 5-3 PIPE CONNECTION diagram (page 7)
Fig. 4

Charge hose (for R410A)

Remove the gauge manifold valve quickly from the service port of the stop valve.

After refrigerant pipes are connected and evacuated, fully open all stop valves on both sides of gas pipe and liquid pipe. Operating without fully opening lowers the performance and this causes trouble.

2. Outdoor unit connection • Connect pipes to the pipe joint part of the stop valve in the same method as the indoor unit. - For tightening, use the same tightening torque applied for indoor unit and tighten the flare nut with

Pipe length up to 40 m No gas charge is needed.

Pipe length exceeding 40 m Charge the prescribed amount of gas. (refer to 5-1)

torque wrench or spanner.

INSULATION AND TAPING

  • 1 Cover piping joints with pipe cover. 2 For outdoor unit side, surely insulate every piping including valves. 3 Using piping tape E , apply taping starting from the entry of outdoor unit.
  • Fix the end of piping tape E with adhesive tape.
  • When piping has to be arranged through above ceiling, closet or area where the temperature and humidity are high, wind additional commercially sold insulation for prevention of condensation.

Tighten the cap to the service port to obtain the initial status.

Retighten the cap.

Show 14 more labels / short text on this page
Flaring tool · York · Die · Die · Copper pipe · Flare nut · Copper pipe · Smooth all around · Handle Low · Handle High · Service port · Vacuum pump · Window · Leak test
Page 8 of the Mitsubishi Electronics MXZ-4A80VA user manual — [How to lock the operation mode]
Page 8 · click to enlarge
Page 8

5-7 LOWERING THE OPERATING NOISE OF THE OUTDOOR UNIT

Mitsubishi Electronics MXZ-4A80VA — 5-7 LOWERING THE OPERATING NOISE OF THE OUTDOOR UNIT diagram (page 8)
Fig. 5
  • Description of the function: With this function, you can lower the operating noise of the outdoor unit when the operation load is small, for example, during nighttime in COOL mode. However, please note that the cooling and heating capacity can also be lowered if this function is activated.
Mitsubishi Electronics MXZ-4A80VA — 5-7 LOWERING THE OPERATING NOISE OF THE OUTDOOR UNIT diagram (page 8)
Fig. 6

Tightening torque N·m kgf·cm Cap for service port 13.7 to 17.7 140 to 180 Cap for stop valve 19.6 to 29.4 200 to 300

* Initial setting is required to activate this function. Please ex- plain about this function to your customers and ask them whether they want to use it.

5-5 EARTHING WORK

Put the earth circuit to the ground in accordance with “Technical Standards for Electrical Installation”.

[How to lower the operating noise]

1Be sure to turn off the main power for the air conditioner before making the setting. 2Set the 3rd Dip Switch of SW1 on the outdoor controller board to ON to enable this function. 3Turn on the main power for the air conditioner.

Lower the operating noise

The product incorporates a frequency inverter and so requires earthing in order to observe electric charge and noise caused by static electricity.

5-8 CHECKING AFTER INSTALLATION

5-6 LOCKING THE OPERATION MODE OF THE AIR CONDITIONER (COOL, DRY, HEAT)

After finishing the installation, check the following items again by marking .

Have special circuits been provided? Is power supply voltage as specified? Has indoor/outdoor connecting wire been inserted into terminal block? Has indoor/outdoor connecting wire been secured firmly? Has intermediary connection between power cable and indoor/outdoor connecting wire been carried out? Is combination of connection pipes and indoor/outdoor connecting wire correct (Room A, Room B, Room C, Room D)? Is earth cable connection correct? Has leak test been carried out? Has air purge been carried out? Is stop valve fully open? Has drain discharge been checked? Is insulation over connection pipe joints correct? Is strength of installation location well enough? Have all of WARNING and CAUTION items in “1. THE FOLLOWING SHOULD ALWAYS BE OB- SERVED FOR SAFETY” been checked?

  • Description of the function: With this function, you can lock the operation mode of the outdoor unit. Once the operation mode is locked to either COOL/DRY mode or HEAT mode, the air conditioner operates in that mode only.

* Initial setting is required to activate this function. Please ex- plain about this function to your customers and ask them whether they want to use it.

[How to lock the operation mode]

1Be sure to turn off the main power for the air conditioner before making the setting. 2Set the 2nd Dip Switch of SW1 on the outdoor controller board to ON to enable this function. 3To lock the operation mode in COOL/DRY mode, set the 1st Dip Switch of SW1 on the outdoor controller board to OFF. To lock the operation in HEAT mode, set the same switch to ON. 4Turn on the main power for the air conditioner.

Page 9 of the Mitsubishi Electronics MXZ-4A80VA user manual — 5-11 EXPLANATION TO THE CUSTOMER
Page 9 · click to enlarge
Page 9

5-9 GAS CHARGE

5-10 TEST RUN

Perform gas charge to unit.

  • Be sure to perform the test run for each unit. Make sure each indoor unit operates properly following the installation manual attached to the unit.
  • If you perform the test run for all indoor units at once, you cannot detect any erroneous connection, if any, of the refrigerant pipes and the indoor/outdoor unit connecting wires. About the restart protective mechanism Once the compressor stops, the restart preventive device operates so the compressor will not operate for 3 minutes to protect the air conditioner.

1Connect gas cylinder to the service port of stop valve. 2Perform air purge of the pipe (or hose) coming from refrigerant gas cylinder. 3Replenish specified amount of the refrigerant, while operating the air conditioner for cooling.

5-11 EXPLANATION TO THE CUSTOMER

  • Recommend the customer to read the OPERATING INSTRUCTIONS carefully.
  • Using the OPERATING INSTRUCTIONS for each unit, explain the following to the customer, how to control temperature, how to remove the air filters, how to remove or put the remote controller in the remote controller holder, how to clean, precautions for operation, etc.

If the customer (user) is absent, explain to the purchaser (owner, building’s controller, etc) about those points.

To maintain the high pressure of the gas cylinder, warm the gas cylinder with warm water (under 40°C) during cold season. But never use naked fire or steam.

Mitsubishi Electronics MXZ-4A80VA — 5-11 EXPLANATION TO THE CUSTOMER diagram (page 9)
Fig. 7
Mitsubishi Electronics MXZ-4A80VA — 5-11 EXPLANATION TO THE CUSTOMER diagram (page 9)
Fig. 8

Refrigerant gas cylinder operating valve (for R410A)

Gauge manifold valve (for R410A) Charge hose (for R410A)

Refrigerant gas cylinder for R410A with siphon

Electronic scale for refrigerant charging

Indoor · unit · Refrigerant (liquid)

Page 10 of the Mitsubishi Electronics MXZ-4A80VA user manual — 5-9 GAS CHARGE
Page 10 · click to enlarge
Page 10
Page 10 of the Mitsubishi Electronics MXZ-4A80VA user manual — 5-9 GAS CHARGE
Page 11 of the Mitsubishi Electronics MXZ-4A80VA user manual — 5-9 GAS CHARGE
Page 11 · click to enlarge
Page 11
Page 11 of the Mitsubishi Electronics MXZ-4A80VA user manual — 5-9 GAS CHARGE
Page 12 of the Mitsubishi Electronics MXZ-4A80VA user manual — SG79Y674H01
Page 12 · click to enlarge
Page 12
HEAD OFFICETOKYO BLDG., 2-7-3, MARUNOUCHI, CHIYODA-KU, TOKYO 100-8310, JAPAN

SG79Y674H01

Ask about the Mitsubishi Electronics MXZ-4A80VA

Owners and our team usually reply within a day — and your question helps the next person too.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
No questions yet about the Mitsubishi Electronics MXZ-4A80VA

Be the first to ask — other owners or our team will answer.

Original document

Mitsubishi Electronics MXZ-4A80VA manual PDF

12 pages·560 KB·Air Conditioner·PDF
Click any page above to open it here
Page 1 / …
100%
Loading pages…