Instruction/ maintenance manual of the product DA 5990 W Ext Miele
Go to page of 36
Operating and installation instructions Cooker hood DA 5960 W, DA 5990 W, DA 5990 W EXT To avoid the risk of accidents or damage to this appliance it is essential to read these instructions before it is installed and used for the first time.
Caring for the environment ..........................................3 Warning and Safety instructions .....................................4 Guide to the appliance ............................................1 0 Modes of operation ...................
Disposal of the packing material The transport and protective packing has been selected from materials which are environmentally friendly for disposal, and can normally be recycled. Packaging e.g. cling film, polystyrene and plastic wrappings must be kept out of the reach of babies and young children.
This appliance complies with all relevant local and national safety requirements. Inappropriate use can, however, lead to personal injury and damage to property. To avoid the risk of accidents and damage to the appliance, please read these instructions carefully before using it for the first time.
Technical safety ~ Before installation, check the cooker hood for visible signs of damage. Under no circumstances should you use a damaged appliance. A damaged appliance is dangerous.
~ Do not connect the appliance to the mains electricity supply by a multi-socket unit or an extension lead. These do not guarantee the required safety of the appliance (e.g. danger of overheating). ~ For appliances with an external fan motor fitted (.
In order to ensure safe operation, and to prevent gases given off by the heating appliances from being drawn back into the room when the cooker hood and the heater are in operation simultaneously, an underpressure of 0.04 mbar (4 pa) is the maximum permissible in the room.
Correct use ~ Never use an open flame beneath the cooker hood. To avoid the danger of fire, do not flambé or grill over an open flame. When switched on, the cooker hood could draw flames into the filter. Fat particles drawn into the cooker hood present a fire hazard.
~ Safety regulations prohibit the fitting of a cooker hood over solid fuel stoves. ~ All ducting, pipework and fittings must be of non-flammable material. These can be obtained from the Miele Spare Parts department or from builders' merchants. ~ The appliance must not be connected to a chimney or vent flue which is in use.
Guide to the appliance 10 dai2406.
a Telescopic extension piece b Tower c Controls d Hob lighting e Recirculation grille (only for recirculation mode) f Canopy g Charcoal filter (accessory required for recirculation mode) h Grease filt.
The cooker hood works with . . . air extraction: The air is drawn in, cleaned by the grease filter and then directed outside. If the on-site ventilation system does not have a non-return flap , then the non-return flap supplied with the appliance must be fitted in the exhaust socket in the motor unit.
To switch the fan on ^ Press the On/Off control. The fan will come on at power level lI. If the cooker hood has been connected to a window contact switch via the Miele DSM 400 control module, then the fan cannot be switched on if the window is shut. The indicator lamp will flash.
Automatic switch-off of the Intensive setting You can set the Intensive setting so that it only runs for 10 minutes before reverting automatically to level III.
Before any cleaning or maintenance work is carried out, disconnect the cooker hood from the mains supply. Ensure that: – it is switched off at the isolator, or – it is switched off at the wall soc.
Controls The controls may suffer discolouration or damage if soiling is left on them for too long. Remove soiling straight away. Observe the General notes on cleaning earlier in this section. Do not use stainless steel cleaning agents on the controls.
Cleaning the grease filter by hand ^ Clean the filter with a soft nylon brush in a mild solution of hot water and a little washing-up liquid. Do not use "neat" washing up liquid. Do not use: – cleaning agents containing descaling agents, – powder cleaners, cream cleaners or abrasive all-purpose cleaners.
Fitting and replacing the charcoal filter If the cooker hood is connected for recirculation, a charcoal filter must be inserted in addition to the grease filter. This is designed to absorb cooking odours. It is fitted in the canopy above the grease filter.
Changing a halogen lamp , Before any cleaning or maintenance work is carried out, disconnect the cooker hood from the mains supply. Ensure that: – it is switched off at the isolator, or – it is sw.
The diagram is not drawn to scale. Appliance dimensions 20.
a Extraction b Recirculation c Ventilation grill positioned at the top for recirculation d , e The shaded areas represent the wall or ceiling area for the vent cut-out and for fitting the connection socket. For recirculation mode, you only require cut-out area 4) and a connection socket.
– When deciding on the safety distance between the hob and cooker hood, please note that a distance of 650 mm above electric cookers/hobs may be preferable to give more working space under the hood. – Account should also be taken of the height of the person who will be using the hood most often.
Before installation, it is important to read the information given on the following pages as well as the "Appliance dimensions" and the "Warning and Safety instructions" at the beginning of this booklet.
Assembly parts Installation 24 dai2411.
a 3 protective sheets for use when fitting the tower. b 2 hose clips for securing the exhaust ducting. c 1 reducing collar for C 125 mm exhaust ducting. d 1 non-return valve for fitting into the exhaust connection on the motor unit (not for recirculation mode).
Important: To avoid the danger of toxic fumes please observe the Warning and Safety instructions. This is especially crucial when using the cooker hood at the same time as another heating appliance which relies on air from the same room. The cooker hood should be installed according to local and national building regulations.
Important: If the exhaust ducting is to run through rooms, ceiling space etc. where there may be great variations in temperature between the different areas, the problem of condensation will need to be addressed. The exhaust ducting will need to be suitably insulated.
All electrical work should be undertaken by a suitably qualified and competent person in strict accordance with current national and local safety regulations (BS 7671 in the UK). Installation, repairs and other work by unqualified persons could be dangerous, for which the manufacturer cannot be held liable.
The Miele DSM 400 Control module can be used to combine the cooker hood with other components. It enables the following: Connection to a window contact switch If adequate ventilation to the room can o.
Connection to a light switch The control module can be used to switch on the cooker hood lighting via a light switch in the house. Installation The tower needs to be removed before the control module can be fitted to the fan unit. The control module is supplied with its own detailed operating and installation instructions.
In the event of a fault which you cannot correct yourself, or if the appliance is under guarantee, please contact: – Your Miele Dealer / Chartered Agent or – The Miele Customer Contact Centre (see back cover for address). When contacting your Dealer or Miele, please quote the model and serial number of your appliance.
Total connected load ..........2 5 0W - Fan motor .................2 0 0W - Hob lighting ..............1x5 0W Voltage ................. A C2 3 0V Frequency .................. 5 0H z Fuse rating ....................5A Electrical cable length .........1 .
33.
34.
35.
Alteration rights reserved / 4209 M.-Nr. 07 598 080 / 01.
An important point after buying a device Miele DA 5990 W Ext (or even before the purchase) is to read its user manual. We should do this for several simple reasons:
If you have not bought Miele DA 5990 W Ext yet, this is a good time to familiarize yourself with the basic data on the product. First of all view first pages of the manual, you can find above. You should find there the most important technical data Miele DA 5990 W Ext - thus you can check whether the hardware meets your expectations. When delving into next pages of the user manual, Miele DA 5990 W Ext you will learn all the available features of the product, as well as information on its operation. The information that you get Miele DA 5990 W Ext will certainly help you make a decision on the purchase.
If you already are a holder of Miele DA 5990 W Ext, but have not read the manual yet, you should do it for the reasons described above. You will learn then if you properly used the available features, and whether you have not made any mistakes, which can shorten the lifetime Miele DA 5990 W Ext.
However, one of the most important roles played by the user manual is to help in solving problems with Miele DA 5990 W Ext. Almost always you will find there Troubleshooting, which are the most frequently occurring failures and malfunctions of the device Miele DA 5990 W Ext along with tips on how to solve them. Even if you fail to solve the problem, the manual will show you a further procedure – contact to the customer service center or the nearest service center