Operating and installation instructions Cooker hood DA 396 DA 399 To avoid the risk of accidents or damage to this appliance it is essential to read these instructions before it is installed and used for the first time.
Caring for the environment . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 Warning and Safety instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 Guide to the appliance . . . .
Disposal of the packing material The transport and protective packing has been selected from materials which are environmentally friendly for disposal, and can normally be recycled. Packaging e.g. cling film, polystyrene and plastic wrappings must be kept out of the reach of babies and young children.
This appliance complies with all relevant local and national safety requirements. Inappropriate use can, however, lead to personal injury and damage to property. To avoid the risk of accidents and damage to the appliance, please read these instructions carefully before using it for the first time.
~ Before connecting the appliance to the mains supply, make sure that the voltage and frequency details given on the data plate correspond with the on-site electricity supply, otherwise the appliance could be damaged. Consult a qualified electrician if in any doubt.
~ Do not connect the appliance to the mains electricity supply by a multi-socket unit or an extension lead. These do not guarantee the required safety of the appliance (e.g. danger of overheating). ~ This appliance may only be used in mobile installations such as ships, caravans, aircraft etc.
In order to ensure safe operation, and to prevent gases given off by the heating appliances from being drawn back into the room when the cooker hood and the heater are in operation simultaneously, an underpressure of 0.04 mbar (4 pa) is the maximum permissible in the room.
Correct use ~ Never use an open flame beneath the cooker hood. To avoid the danger of fire, do not flambé or grill over an open flame. When switched on, the cooker hood could draw flames into the filter. Fat particles drawn into the cooker hood present a fire hazard.
~ Safety regulations prohibit the fitting of a cooker hood over solid fuel stoves. ~ All ducting, pipework and fittings must be of non-flammable material. These can be obtained from the Miele Spare Parts department or from builders' merchants. ~ The appliance must not be connected to a chimney or vent flue which is in use.
Guide to the appliance 10.
a Extension piece b Tower c Canopy d Control panel e Grease filter f Recirculation grille (only for recirculation mode) g Hob lighting h Charcoal filter (special accessory for recirculation mode) i Hob lighting switch j Sliding switch for the fan To switch on, slide the switch to the required setting.
The cooker hood works with . . . air extraction: The air is drawn in and cleaned by the grease filters and directed outside. If the on-site ventilation system does not have a non-return flap , the non-return flap supplied with the appliance must be fitted in the exhaust socket in the motor unit.
Before any cleaning or maintenance work is carried out, disconnect the cooker hood from the mains supply. Ensure that: – it is switched off at the wall socket and the plug is withdrawn, or – the f.
Important for appliances with lacquered housing (special finish) It is very difficult to clean this type of surface without causing minor marks to the surface material. This can become particularly noticeable with darker colours and if there is halogen lighting in the kitchen.
Cleaning the grease filters by hand ^ Clean the filters with a soft nylon brush in a mild solution of hot water and a small amount of washing-up liquid. Do not use undiluted washing up liquid. Do not use: – cleaning agents containing descaling agents, – powder cleaners, cream cleaners or abrasive all-purpose cleaning agents, – oven sprays.
Fitting and replacing the charcoal filter If the cooker hood is connected for recirculation, a charcoal filter must be inserted in addition to the grease filters. It is designed to absorb cooking odours, and is fitted in the canopy above the grease filters.
Changing a halogen lamp Before any cleaning or maintenance work, disconnect the cooker hood from the mains supply. Ensure that – it is switched off at the wall socket and the plug is withdrawn, or .
DA 396 DA 399 1) Extraction 2) Recirculation 3) Ventilation grille position for recirculation 4) and 5): (5 is not required for recirculation mode cooker hoods) The shaded area represents the wall or ceiling area for the vent cut-out, and for fitting the connection socket.
Safety distance between hob and cooker hood (S) When planning the installation height of your cooker hood, the minimum safety distance between the top of a cooker or hob and the bottom of the cooker h.
Assembly parts Installation 20.
a 3 protective sheets for use when fitting the tower. b 2 hose clips for securing the exhaust ducting. c 1 reducing collar for exhaust ducting C 125 mm. d 1 non-return valve for fitting into the exhaust socket on the motor unit (for extraction mode only) e Upper retaining plate for securing the extension piece.
Before installation, it is important to read the information given on the following pages as well as the "Appliance dimensions" and the "Warning and Safety instructions" at the beginning of this book.
All electrical work should be undertaken by a suitably qualified and competent person in strict accordance with current national and local safety regulations (BS 7671 in the UK). Installation, repairs and other work by unqualified persons could be dangerous, for which the manufacturer cannot be held liable.
, Important: To avoid the danger of toxic fumes, please observe the Warning and Safety instructions. This is especially crucial when using the cooker hood at the same time as another heating appliance which relies on air from the same room. The cooker hood should be installed according to local and national building regulations.
Important: If the exhaust ducting is to run through rooms, ceiling space etc. where there may be great variations in temperature between the different areas, the problem of condensation will need to be addressed. The exhaust ducting will need to be suitably insulated.
In the event of a fault which you cannot correct yourself, or if the appliance is under guarantee, please contact: – Your Miele Dealer / Chartered Agent or – The Miele Customer Contact Centre (see back cover for address). When contacting your Dealer or Miele, please quote the model and serial number of your appliance.
Total connected load ..........2 2 0W Fan motor .................1 2 0W Hob lighting ..............2x5 0W Voltage ..................A C2 3 0V Frequency .................~5 0H z Fuse rating GB .................3A AUS, NZ: Plug rating ..................
Alteration rights reserved / 4209 M.-Nr. 06 417 570 / 10.
An important point after buying a device Miele DA 399-5 Ext (or even before the purchase) is to read its user manual. We should do this for several simple reasons:
If you have not bought Miele DA 399-5 Ext yet, this is a good time to familiarize yourself with the basic data on the product. First of all view first pages of the manual, you can find above. You should find there the most important technical data Miele DA 399-5 Ext - thus you can check whether the hardware meets your expectations. When delving into next pages of the user manual, Miele DA 399-5 Ext you will learn all the available features of the product, as well as information on its operation. The information that you get Miele DA 399-5 Ext will certainly help you make a decision on the purchase.
If you already are a holder of Miele DA 399-5 Ext, but have not read the manual yet, you should do it for the reasons described above. You will learn then if you properly used the available features, and whether you have not made any mistakes, which can shorten the lifetime Miele DA 399-5 Ext.
However, one of the most important roles played by the user manual is to help in solving problems with Miele DA 399-5 Ext. Almost always you will find there Troubleshooting, which are the most frequently occurring failures and malfunctions of the device Miele DA 399-5 Ext along with tips on how to solve them. Even if you fail to solve the problem, the manual will show you a further procedure – contact to the customer service center or the nearest service center