Instruction/ maintenance manual of the product da 186 Miele
Go to page of 28
Operating and installation instructions Cooker hood DA 186 To avoid the risk of accidents or damage to this appliance, it is essential to read these instructions before it is installed and used for the first time.
Caring for the environment . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 Warning and Safety instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 Modes of operation . . . . . .
Disposal of the packing material The transport and protective packing has been selected from materials which are environmentally friendly for disposal, and should be recycled. Packaging e.g. cling film, polystyrene and plastic wrappings must be kept out of the reach of babies and young children.
This appliance complies with all relevant local and national safety requirements. Inappropriate use can, however, lead to personal injury and damage to property. To avoid the risk of accidents and damage to the appliance, please read these instructions carefully before using it for the first time.
Technical safety ~ Before installation, check the cooker hood for visible signs of damage. Under no circumstances should you use a damaged appliance. A damaged appliance is dangerous.
~ Do not connect the appliance to the mains electricity supply by a multi-socket unit or an extension lead. These do not guarantee the required safety of the appliance (e.g. danger of overheating). ~ This appliance must not be used in a non-stationary location (e.
In order to ensure safe operation, and to prevent gases given off by the heating appliances from being drawn back into the room when the cooker hood and the heater are in operation simultaneously, an underpressure in the room of 0.04 mbar (4 pa) is the maximum permissible.
~ Do not use the cooker hood without the filters in place. This way you will avoid the risk of grease and dirt getting into the appliance and hindering its smooth operation. ~ The filters should be regularly cleaned or changed as appropriate. Saturated filters are a fire hazard.
The cooker hood works with . . . air extraction: The air is drawn in and cleaned by the grease filters and directed outside. If the on-site ventilation system does not have a non-return flap , the non-return flap supplied must be fitted. This flap is closed when the cooker hood is switched off.
Guide to the appliance / Operation 10.
a Recirculation grille (only for recirculation mode) b Exhaust connection c Adjustable bracket d Vapour canopy to which a furniture door front is fitted e Charcoal filter (extra accessory available to order for recirculation mode) f Hob lighting g Grease filters h Control panel Operation To switch on the fan ^ Open the vapour canopy.
A range of Miele branded cleaning and conditioning products is available to order from Miele (see back page for details) or via the internet at www.miele-shop.com. , Before carrying out any cleaning or maintenance work, disconnect the cooker hood from the mains supply.
Grease filters The re-usable metal grease filters in the appliance remove solid particles (grease, dust, etc.) from the kitchen vapours, preventing soiling of the cooker hood. They should be cleaned at least every 3-4 weeks to avoid grease sticking hard to them.
Charcoal filters If the cooker hood is being used on recirculation mode, two DKF 14-1 charcoal filters must be fitted behind the grease filters. ^ Open the vapour canopy ^ Remove the grease filters. ^ Unwrap the charcoal filters. ^ Position the charcoal filters on either side of the fan as shown, and twist securely into place.
Changing a halogen lamp , Before any cleaning or maintenance work, disconnect the cooker hood from the mains supply. , Exercise caution when changing halogen lamps.
In the event of a fault which you cannot correct yourself, or if the appliance is under guarantee, please contact: – your Miele Dealer or – the Miele Service Department (see back cover for contact details).
* Furniture panel dimensions Connection for air extraction C 150 mm, or C 120 mm with reducing collar. Safety distance between hob and cooker hood The distance betwen the top of the cooker/hob and the bottom of the cooker hood must measure at least 650 mm , unless a greater distance is specified by the manufacturer.
Before installation, it is important to read the information given on the following pages as well as the Warning and Safety instructions at the beginning of this booklet.
Depth adjustment ^ The depth of the unit "T" can be adjusted from 275 to 360 mm by means of the adjustable brackets. ^ Slightly loosen the screws on the brackets. ^ Then pull the brackets out until you achieve the required depth "T".
^ The recirculation grille must be removed when the hood is used in extraction mode. ^ Hang the cooker hood in position using the adjustable brackets. ^ Position the vapour canopy with the furniture door front fitted, and close it. The movement of the vapour canopy can be adjusted if necessary, for instance where a heavy furniture door is fitted.
Height adjustment ^ Using the screws at the back of the adjustable brackets, align the cooker hood height with that of neighbouring units. Turn the screw – anti-clockwise : to raise the appliance. – clockwise : to lower the appliance. ^ If necessary adjust the depth again.
With air extraction: If the on-site ventilation system does not have a non-return flap, one of the two non-return flaps supplied (for C 150 mm or C 120 mm ducting) must be fitted. –I f C 150 mm ducting is being used, the non-return flap should be fitted onto the exhaust connection.
All electrical work should be undertaken by a suitably qualified and competent person in strict accordance with current national and local safety regulations (BS 7671 in the UK). Installation, repairs and other work by unqualified persons could be dangerous, for which the manufacturer cannot be held liable.
Important: To avoid the danger of toxic fumes, please observe the Warning and Safety instructions. This is especially crucial when using the cooker hood at the same time as another heating appliance which relies on air from the same room. The cooker hood should be installed according to local and national building regulations.
Total connected load ..........1 7 5W Fan motor .................1 3 5W Hob lighting ..............2x2 0W Voltage ................. A C2 3 0V Frequency .................~5 0H z Fuse rating (UK) ................5A Electrical cable length .........1 . 8m Fan performance Extraction power according to EN 61591 Extraction system C 150 mm: Level I .
26.
27.
Alteration rights reserved / 3011 M.-Nr. 07 623 170 / 03.
An important point after buying a device Miele da 186 (or even before the purchase) is to read its user manual. We should do this for several simple reasons:
If you have not bought Miele da 186 yet, this is a good time to familiarize yourself with the basic data on the product. First of all view first pages of the manual, you can find above. You should find there the most important technical data Miele da 186 - thus you can check whether the hardware meets your expectations. When delving into next pages of the user manual, Miele da 186 you will learn all the available features of the product, as well as information on its operation. The information that you get Miele da 186 will certainly help you make a decision on the purchase.
If you already are a holder of Miele da 186, but have not read the manual yet, you should do it for the reasons described above. You will learn then if you properly used the available features, and whether you have not made any mistakes, which can shorten the lifetime Miele da 186.
However, one of the most important roles played by the user manual is to help in solving problems with Miele da 186. Almost always you will find there Troubleshooting, which are the most frequently occurring failures and malfunctions of the device Miele da 186 along with tips on how to solve them. Even if you fail to solve the problem, the manual will show you a further procedure – contact to the customer service center or the nearest service center