Installation and user manual www .mgeups.com Pulsar Evolution 2200/3000/3000 XL.
Page 2 - 3400723100/AD SA VE THESE INSTRUCTIONS. This manual contains important instructions for 89347, 89348, and 89349 that should be followed during installation and maintenance of the UPS and batteries. Thank you for selecting an MGE UPS SYSTEMS product to protect your electrical equipment.
3400723100/AD - Page 3 Introduction CAUTION: Safety of persons ◗ The UPS has its own internal power source (the battery). Consequently , the power outlets may be energized even if the UPS is disconnected from the AC-power source. ◗ Dangerous voltage levels are present within the UPS.
Page 4 - 3400723100/AD Foreword Using this document IMPORT ANT : Important instructions that must always be followed. NOTE: Information, advice, help. Visual indication. Action. Audio indication. In the illustrations on the following pages, the symbols below are used: LED off.
3400723100/AD - Page 5 Contents 1. Presentation 1.1 Overall view .................................................................................................................................. 7 T ower position .....................................
Page 6 - 3400723100/AD Contents 6. Appendices 6.1 T echnical data ..............................................................................................................................24 Simplified diagram .....................................
3400723100/AD - Page 7 1. Presentation 1.1 Overall view T ower position Rack position P U L S A R Evolution 3 0 0 0 P U L S A R Evolution 3 0 0 0 W H D Dimensions in inches (W x H x D) Evolution 2200 Evolution 3000 17.
5-20P 72Vdc, 7Ah Pb 344-50 2 8 2 -00 TO B A TTERY C A B IN ET R S 2 3 2 S I TE W I R IN G 3 b attery c a b inets max F A UL T W A R NIN G O U T D ata l ine p r o te c ti o n IN H ert z 50 /6 0 Hz H er.
3400723100/AD - Page 9 1 2 % % 1.3 Control panel Bar graph indicating percent load at output. Group 1 programmable receptacles supplied with power . Illuminated ON/OFF button for the receptacles. Group 2 programmable receptacles supplied with power . Operation on battery power .
P U L S A R Evolution 3 0 0 0 Page 10 - 3400723100/AD 2. Installation 2.1 Unpacking and parts check RS232 communications cable for Windows Operating Systems. For UNIX/Linux Operating Systems, please order , for free, the following part number: 66090 USB communications cable.
3400723100/AD - Page 11 2. Installation 2.2 Upright installation (tower position) Connect the two supports for the upright position. P U L S A R Evolution 3 0 0 0 P U L S A R Evolution 3 0 0 0.
P U L S A R Evolution 3 0 0 0.
3400723100/AD - Page 13 H ert z 50 /6 0 Hz H ert z 50 /6 0 Hz A m p s 1 6 A M A X V ol t 1 2 0 V ~ 1 O V ol t 1 2 0 V ~ 1 O W / VA 1 540 W / 1 9 2 0 VA V ol t : 72Vdc 40 A A C O u t p u t A C I n p u t U . S . P A T . N o . 6 , 0 9 4 , 3 6 3 B A TTERY C O NN E C TOR U .
Only for 3000 72Vdc, 9Ah Pb 344-50297-00 TO BATTERY RS232 CABINET IN SITE WIRING FAULT max for 3000XL max for 3000 12 battery cabinets WARNING 3 battery cabinets OUT Data line protection Volt: 72Vdc 40A BATTERY CONNECTOR U.
3400723100/AD - Page 15 2. Installation 2.7 Installation of the communications-card option 1 - Remove the slot cover 5 secured by two screws. 2 - Insert the card in the slot. 3 - Secure the cover with the two screws. It is not necessary to shut down the UPS to install the communications card.
Page 16 - 3400723100/AD 1 2 % % 3. Operation 3.1 Start-up 15 16 17 Press the ON / OFF button 15 . The buzzer beeps and all the LEDs come ON. The buzzer beeps twice during the self-test, then button 15 remains ON, indicating that the receptacles are supplied with power .
3400723100/AD - Page 17 1 2 % % 1 2 % % 3. Operation 3.3 Operation on battery power (following failur e of AC-input power) T ransfer to battery power The AC-input power is out of tolerances, LED 16 goes ON. During operation on battery power , the buzzer beeps every ten seconds.
Page 18 - 3400723100/AD 3. Operation 3.4 Personalization (optional) Function Configurable function Automatic restart Cold start Forced reboot Energy saving UPS ON / OFF via software Default setting En.
3400723100/AD - Page 19 3. Operation Configurable function Output voltage on battery power Upper threshold for transfer to battery power Fader-mode cut-in threshold Booster-mode cut-in threshold Lower.
Page 20 - 3400723100/AD T roubleshooting requiring MGE UPS SYSTEMS after-sales support 4. Maintenance 4.1 T rouble-shooting Indication LED 17 goes ON and the buzzer sounds continuously . Signification UPS electronics have detected a UPS fault. ◗ The connected equipment is no longer supplied.
3400723100/AD - Page 21.
Page 22 - 3400723100/AD I H F G 4. Maintenance Installation of the new battery module Carry out the above operation in reverse order . ◗ CAUTION: risk of electric arc when connecting the battery . ◗ T o maintain an identical level of performance and safety , use a battery module identical to that previously mounted in the UPS.
3400723100/AD - Page 23 5. Environment This product has been designed to respect the environment: It does not contain CFCs or HCFCs. UPS recycling at the end of service life: MGE UPS SYSTEMS undertake.
Page 24 - 3400723100/AD 6. Appendices 6.1 T echnical data Simplified diagram Input Output Battery Charger Inverter Booster / fader transformer Filter.
3400723100/AD - Page 25 6. Appendices T echnical characteristics Output rating AC-input power ◗ V oltage ◗ Frequency Output power (operation on battery power) ◗ V oltage ◗ Frequency Battery En.
Page 26 - 3400723100/AD 6. Appendices Examples of battery backup times Pulsar Evolution 2200 Pulsar Evolution 3000 Pulsar Evolution 3000 XL + 3 EXB 1 data server + 1 hard disk 2 distributed servers + .
3400723100/AD - Page 27 6. Appendices 6.2 Glossary Backup time T ime that the connected equipment can operate on battery power if AC-input power fails. Bar graph Device on the front panel indicating the percent remaining backup time or the percent load.
Page 28 - 3400723100/AD 6. Appendices 6.3 Index A Automatic start ................................................................18 B Bar graph ..........................................................................9 Battery Additional modules ...
.
.
.
1660 Scenic Avenue Costa Mesa, CA 92626 USA www .mgeups.com.
An important point after buying a device MGE UPS Systems 3000 XL (or even before the purchase) is to read its user manual. We should do this for several simple reasons:
If you have not bought MGE UPS Systems 3000 XL yet, this is a good time to familiarize yourself with the basic data on the product. First of all view first pages of the manual, you can find above. You should find there the most important technical data MGE UPS Systems 3000 XL - thus you can check whether the hardware meets your expectations. When delving into next pages of the user manual, MGE UPS Systems 3000 XL you will learn all the available features of the product, as well as information on its operation. The information that you get MGE UPS Systems 3000 XL will certainly help you make a decision on the purchase.
If you already are a holder of MGE UPS Systems 3000 XL, but have not read the manual yet, you should do it for the reasons described above. You will learn then if you properly used the available features, and whether you have not made any mistakes, which can shorten the lifetime MGE UPS Systems 3000 XL.
However, one of the most important roles played by the user manual is to help in solving problems with MGE UPS Systems 3000 XL. Almost always you will find there Troubleshooting, which are the most frequently occurring failures and malfunctions of the device MGE UPS Systems 3000 XL along with tips on how to solve them. Even if you fail to solve the problem, the manual will show you a further procedure – contact to the customer service center or the nearest service center