H200 & H200HF SERIES W A TER CONDITIONERS Apartment Buildings Boiler W ater T reatment Car W ashes Commercial Buildings Condominiums Factories Hospitals Laundries Mobile Home Parks Motels and Hote.
Hellenbrand Means Quality and Reliability Since 1967, Hellenbrand, Inc. has provided water solutions to the water tr eatment industry in the U.S. and around the world.
• Solid state micropr ocessor can control fr om one to four units allowing you system add on capabilities as your needs grow . • Regeneration may be initiated with a time clock, meter delayed or meter immediate.
H200/H200HF Diagnostic and Histor y Screens provide the water treatment operator with a wealth of information. Diagnostic Screens • Days since last regeneration • T otal volume treated since last .
H200/H200HF Diagnostic and Histor y Screens provide the water treatment operator with a wealth of information. DIAGNOSTIC 5 DIAGNOSTIC 6 DIAGNOSTIC 7 DIAGNOSTIC 7-B WS2H Control V alve Manual Page 21 Diagnostic Screens (continued) DIAGNOSTICS 5 Maximum fl ow rate for the last 28 days.
H200/H200HF Diagnostic and Histor y Screens provide the water treatment operator with a wealth of information. HISTOR Y 1 HISTOR Y 2 HISTOR Y 3 Page 22 WS2H Control V alve Manual V alve History Returns to normal operation after 5 minutes.
Modes of Regeneration Time Clock - 7 or 28 day calendar clock shall initiate regeneration at a pr e-set time of day . Parallel Individual Meters - All units are in service at the same time with either delayed or immediate r e- generation. A lockout feature or of fsetting time of regeneration pr events more than one unit to r egenerate at a time.
A . MINERAL T ANK: Fiberglass tank with Polyethylene Inner Shell and Fiberglass Roving Manufactured to Operate at 150 psi. NSF Approved. B. DISTRIBUTOR SYSTEM: T wo-Inch Hub & Lateral Dis - tributor for Maximum Service Flow and Minimal Pressure Loss.
Brine T ank(s) Inlet Bypass V alve Brine T ank(s) Outlet Isolation V alves Flex Connectors MA V V alve H200 T win/T riple x/Fourple x Installation T op-Mount - First-in, Last-Out Piping Arrangement.
H200 T win Alternating - Side Mount H200 T win/T riple x/Fourple x Installation - Side Mount First-in, Last-Out Piping Arrangement. Brine T ank See NOTE Figure 7 Figure 6 Brine T ank(s) Figure 7 NOTE:.
H200 HF Single T ank Installation H200 HF T win Alternating Installation H200 HF T riple x/Fourple x Installation Brine T ank See NOTE Figure 7 Figure 8 See NOTE Figure 7 Figure 9 See NOTE Figure 7 Fi.
RECOMMENDED BRINE T ANK APPROXIMA TE PIPE SIZE MINERAL T ANK SIZE SAL T STORAGE SHIPPING WEIGHT -TOP MOUNT MODEL (INCHES) (INCHES) (INCHES) ( LBS) SINGLE TWIN H200-240 2 24 X 72 24 X 50 715 674 1325 H.
RA TED CAP ACITY FLOW RA TES (gpm) RESIN LOW SAL T MEDIUM SAL T HIGH SAL T BKW MODEL CU.FT . GRAINS/LBS GRAINS/LBS GRAINS/LBS 15 PSI 25 PSI GPM H200HF-300-24-3 10 190,000/60 280,000/100 320,000/150 12.
An important point after buying a device Argosy Research H200HF Series (or even before the purchase) is to read its user manual. We should do this for several simple reasons:
If you have not bought Argosy Research H200HF Series yet, this is a good time to familiarize yourself with the basic data on the product. First of all view first pages of the manual, you can find above. You should find there the most important technical data Argosy Research H200HF Series - thus you can check whether the hardware meets your expectations. When delving into next pages of the user manual, Argosy Research H200HF Series you will learn all the available features of the product, as well as information on its operation. The information that you get Argosy Research H200HF Series will certainly help you make a decision on the purchase.
If you already are a holder of Argosy Research H200HF Series, but have not read the manual yet, you should do it for the reasons described above. You will learn then if you properly used the available features, and whether you have not made any mistakes, which can shorten the lifetime Argosy Research H200HF Series.
However, one of the most important roles played by the user manual is to help in solving problems with Argosy Research H200HF Series. Almost always you will find there Troubleshooting, which are the most frequently occurring failures and malfunctions of the device Argosy Research H200HF Series along with tips on how to solve them. Even if you fail to solve the problem, the manual will show you a further procedure – contact to the customer service center or the nearest service center