EN
Meade logo
Official user manual

Meade Telescope Cable Connector (889)

1 pages·167 KB·Camera Accessories·PDF·ENDEFRITNLJA
Meade Telescope Cable Connector (889)
Table of Contents 1 sections Meade ® #887 Advanced Field Tripod; #889 Tripod Adapter ShowHide
Page 1 of the Meade Telescope Cable Connector (889) user manual — Meade ® #887 Advanced Field Tripod; #889 Tripod Adapter
Page 1 · click to enlarge
Page 1

Meade ® #887 Advanced Field Tripod; #889 Tripod Adapter

The #887 Advanced Field Tripod yields rock-solid stability for sensitive applications of the Meade ETX-125 telescope. The #889 Tripod Adapter, included with the #887 Tripod, may also be purchased separately for use with Meade LX10, LX50, or LX200 tripods and permits attachment of the ETX-125 to any of these tripods.

#889 (07367) #887 (07024) Tripod Adapter for ETX-125: Advanced Field Tripod for ETX-125: Adapter (1, Fig.1 and 1, Fig. 2) #889 (07367) Adapter Adapter Knob (qty. 2) (2, Fig. 1 and 2, Fig. 2) Tripod (07019) (3, Fig. 1 and 3, Fig. 2) This instruction sheet Equatorial Wedge (52-1004-04) (6, Fig. 2) Azimuth Control (07044)

Altazimuth Installation (Refer to Figure 1)

Polar Installation (Refer to Figure 2)

1. Attach the adapter to your ETX telescope: Slide the two adapter knobs through the attachment holes on the bottom of the adapter plate. Thread the knobs into the tripod holes on the base of your ETX. Tighten to firm feel only. See Figure 1 for proper orientation.
1. Attach the adapter to your ETX telescope with the two adapter knobs as described in step 1 of the Altazimuth installation. See Figure 2 for proper orientation.
2. Thread the tension lock nut onto the large threaded rod. Orient the lock nut so that the side with the protruding cylinder points upwards. Thread the lock nut down the rod about 3 inches.
2. Attach the equatorial wedge to the tripod as explained on the equatorial wedge instruction sheet (packaged with the equatorial wedge). Attach the azimuth control components as explained on the azimuth control instruction sheet (packaged with the azimuth control).
3. Attach the #889 Adapter/ETX-125 assembly to the tripod by threading the large threaded rod in the center of the tripod head into the large hole on the bottom of the adapter base. Note that three tapped holes are provided in the adapter if a more secure attachment is desired. Use 1/4"- 20 bolts (not supplied).
3. Attach the #889 Adapter/ETX-125 assembly to the wedge: Slide the three tab knobs through the attachment holes of the wedge and thread into the holes provided in the adapter plate tabs.
4. Thread the tension lock nut upwards until it tightens against the base of the tripod.

Figure 1: Alt-Az Assembly. Item 1: Adapter; Item 2: Adapter Knobs; Item 3: Tripod; Item 4: Threaded Rod; Item 5: Tension Lock Nut.

Figure 2: Polar Assembly. Item 1: Adapter; Item 2: Adapter Knobs; Item 3: Tripod; Item 4: Tab Knobs; Item 5: Tabs; Item 6: Equatorial Wedge.

A D V A N C E D P R O D U C T S D I V I S I O N Meade Instruments Corporation World’s Leading Manufacturer of Astronomical Telescopes for the Serious Amateur 6001 Oak Canyon, Irvine, California 92618 I (949) 451-1450 FAX: (949) 451-1460 I www.meade.com © 2000

Ver. 0400 14-6421-00

Ask about the Meade Telescope Cable Connector (889)

Owners and our team usually reply within a day — and your question helps the next person too.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
No questions yet about the Meade Telescope Cable Connector (889)

Be the first to ask — other owners or our team will answer.

Original document

Meade Telescope Cable Connector (889) manual PDF

1 pages·167 KB·Camera Accessories·PDF
Click any page above to open it here
Page 1 / …
100%
Loading pages…