EN
Master Lock logo
Official user manual

Master Lock B70CEA

48 pages·1.2 MB·Air Conditioner·PDF·ENDEFRITNLJA
Master Lock B70CEA
Table of Contents 40 sections R PORTABLE · FORCED AIR HEATERS · Heater Sizes: 35,000 70,000 100,000 150,000 Btu/Hr · Models: B35CEA, B70CEA, B100CEA, and B150CEA · … ShowHide
Page 1 of the Master Lock B70CEA user manual — R PORTABLE
Page 1 · click to enlarge
Page 1

R PORTABLE

FORCED AIR HEATERS

Heater Sizes: 35,000 70,000 100,000 150,000 Btu/Hr

Models: B35CEA, B70CEA, B100CEA, and B150CEA

Page 2 of the Master Lock B70CEA user manual — DANGER: Carbon monoxide poisoning may lead to death!
Page 2 · click to enlarge
Page 2

SAFETY INFORMATION

  • Use only kerosene or No. 1 fuel oil to avoid risk of fire or explosion. Never use gasoline, naphtha, paint thinners, alcohol, or other highly flammable fuels.
  • Fueling a)Personnel involved with fueling shall
  • Use only in well-vented areas. Before using heater, provide at least a 2800 square cm (three-square-foot) opening of fresh, outside air for each 100,000 Btu/Hr of rating.
  • Use only in places free of flammable vapors or high dust content.
  • Use only the electrical voltage and frequency specified on model plate.
  • Use only a three-prong, grounded extension cord.
  • Minimum heater clearances from combustibles: Outlet: 250 cm (8 Ft.) Sides, Top, and Rear: 125 cm (4 Ft.)
  • Locate heater on a stable and level surface if heater is hot or running or a fire may occur.
  • When moving or storing heater, keep heater in a level position or fuel spillage may occur.
  • Keep children and animals away from heater.
  • Unplug heater when not in use.
  • When used with thermostat, heater may start anytime.
  • Never use heater in living or sleeping areas.
  • Never block air inlet (rear) or air outlet (front) of heater.
  • Never move, handle, refuel, or service a hot, operating, or plugged-in heater.
  • Never attach duct work to front or rear of heater. Using duct work could reduce the necessary air flow of heater. Heater would produce excessive carbon monoxide.

WARNINGS

be qualified and thoroughly familiar with the manufacturer's instructions and applicable regulations regard- ing the safe fueling of heating units. b)Only the type of fuel specified on the

heater's data plate shall be used. c)All flame, including the pilot light, if

any, shall be extinguished and the heater allowed to cool, prior to fueling. d)During fueling, all fuel lines and fuel-

line connections shall be inspected for leaks. Any leaks shall be repaired prior to returning the heater to service. e)At no time shall more than one day's

DANGER: Carbon monoxide poisoning may lead to death!

supply of heater fuel be stored inside a building in the vicinity of the heater. Bulk fuel storage shall be outside the structure. f) All fuel storage shall be located a

Carbon Monoxide Poisoning: Early signs of carbon monoxide poisoning re- semble the flu, with headaches, dizziness, and/or nausea. If you have these signs, the heater may not be working properly. Get fresh air at once! Have heater serviced. Some people are more affected by carbon monoxide than others. These include preg- nant women, persons with heart or lung disease or anemia, those under the influence of alcohol, and those at high altitudes.

minimum of 762cm (25 feet) from heaters, torches, welding equipment, and similar sources of ignition (ex- ception: the fuel reservoir integral with the heater unit). g)Whenever possible, fuel storage shall

be confined to areas where floor pen- etrations do not permit fuel to drip onto or be ignited by a fire at lower elevation. h)Fuel storage shall be in accordance

Make certain you read and understand all Warnings. Keep this manual for reference. It is your guide to safe and proper operation of this heater.

  • with the authority having jurisdiction.
  • Never use heater where gasoline, paint thinner, or other highly flammable vapors are present.
  • Follow all local ordinances and codes when using heater.
  • Heaters used in the vicinity of tarpaulins, canvas, or similar enclosure materials shall be located a safe distance from such materials. The recommended minimum safe distance is 304.8cm (10 feet). It is further recommended that these enclosure materials be of a fire retardant nature. These enclosure materials shall be securely fastened to prevent them from igniting or from upsetting the heater due to wind action.

2 104468

Page 3 of the Master Lock B70CEA user manual — SAFETY INFORMATION
Page 3 · click to enlarge
Page 3
Master Lock B70CEA — SAFETY INFORMATION diagram (page 3)
Fig. 1
1. Remove all packing items applied to heater for shipment. 2. Remove all items from carton. 3. Check items for any shipping damage. If heater is damaged, promptly inform dealer where you bought heater.

3 104468

Page 4 of the Master Lock B70CEA user manual — VENTILATION
Page 4 · click to enlarge
Page 4

ASSEMBLY

2. Place cap nuts on axle ends. Gently tap with hammer to secure. 3. Place heater on wheel support frame. Make sure air inlet end (rear) of heater is over wheels. Line up holes on fuel tank flange with holes on wheel sup- port frame. 4. Place front handle and rear handle on top of fuel tank flange. Insert screws through handles, fuel tank flange, and wheel support frame. Attach nut finger tight after each screw is inserted. 5. After all screws are inserted, tighten nuts firmly.

FUELS

(FOR 100,000 AND 150,000 BTU/HR MODELS ONLY)

These models are furnished with wheels and handles. Wheels, handles, and the mounting hardware are found in the shipping carton.

  • Tools Needed
  • Medium Phillips Screwdriver
  • 3/8" Open or Adjustable Wrench
  • Hammer
  • Do not use heavy fuels such as No. 2 fuel oil or No. 2 Diesel. Using heavy fuels will result in:
  • clogged fuel filter and nozzle
  • carbon build up on spark plug
  • use of non-toxic anti-icer in fuel during very cold weather
1. Slide axle through wheel support frame. Install wheels on axle. IMPORTANT: When installing wheels, point extended hub of wheels toward wheel support frame (see Figure 3).
Master Lock B70CEA — (FOR 100,000 AND 150,000 BTU/HR MODELS ONLY) diagram (page 4)
Fig. 2

VENTILATION

Master Lock B70CEA — VENTILATION diagram (page 4)
Fig. 3

Provide a fresh air opening of at least 2800 square cm (three square feet) for each 100,000 Btu/Hr rating. Provide extra fresh air if more heaters are being used.

  • Example: A 150,000 Btu/Hr heater requires one of the following:
  • a 4.88 m (16 foot) wide two-car garage door raised 8.59 cm (3.38 inches)
  • a 2.75 m (9 foot) wide single-car garage door raised 15.24 cm (six inches)
  • two, 76.2 cm (thirty-inch) windows raised 30.48 cm (twelve inches)

Figure 3 - Wheel and Handle Assembly, 100/150,000 Btu/Hr Models Only

Show 5 more labels / short text on this page
Rear Handle · Wheel Support Frame · Wheel · Cap Nut · 4 104468
Page 5 of the Master Lock B70CEA user manual — Extension Cord Wire Size Requirements
Page 5 · click to enlarge
Page 5

THEORY OF OPERATION

OPERATION

Extension Cord Wire Size Requirements

Up to 30.5 meters (100 feet) long, use 1.0 mm2 (16 AWG) conductor 30.6 to 61 meters (101 to 200 feet) long, use 1.5 mm2 (14 AWG) conductor

The Fuel System: The air pump forces air through the air line. The air is then pushed through the burner head nozzle. This air causes fuel to lift from the tank. A fine mist of fuel is sprayed into the combustion chamber.

Heater will start when power cord is plugged into outlet. If not, push in flame-out control reset button (see Figures 5 and 6).

To Start Heater 1. Follow all ventilation and safety infor- mation. 2. Fill fuel tank with kerosene or No. 1 fuel oil. 3. Attach fuel cap. 4. Plug power cord of heater into standard 230 volt/50 hertz, grounded (earthed) outlet. Use an extension cord if needed. Use only a three-prong, grounded (earthed) extension cord.

The Air System: The motor turns the fan. The fan pushes air into and around the combustion chamber. This air is heated and provides a stream of clean, hot air.

To Stop Heater 1. Unplug power cord from outlet.

To Restart Heater 1. Wait 2 minutes after stopping heater. 2. Repeat steps under To Start Heater.

The Ignition System: The electronic ignitor sends voltage to the spark plug. The spark plug ignites the fuel and air mixture.

The Flame-Out Control System: This system causes the heater to shut down if the flame goes out.

Flame-Out Control Reset Button

Spark Plug Combustion Chamber

Clean Heated Air Out

Figure 5 - Flame-Out Control Reset Button, 35/70,000 Btu/Hr

Flame-Out Control Reset Button

Air line To Burner

Air For Fuel System

Air For Combustion And Heating Fuel

Figure 4 - Cross Section Operational View

Figure 6 - Flame-Out Control Reset Button, 100/150,000 Btu/Hr

Show 10 more labels / short text on this page
Motor Air Pump · Intake Air Filter · Burner Head · Fan · Cool Air In · Output Air Filter · Nozzle Fuel Tank · Fuel Filter · Electronic Ignitor · 5 104468
Page 6 of the Master Lock B70CEA user manual — Item
Page 6 · click to enlarge
Page 6

STORING, TRANSPORTING, OR SHIPPING

PREVENTATIVE MAINTENANCE SCHEDULE

Note: If shipping, transport companies re- quire fuel tanks to be empty. 1. Drain fuel tank. Note: Some models have drain plug on underside of fuel tank. If so, remove drain plug to drain all fuel. If heater does not have drain plug, drain fuel through fuel cap opening. Be sure all fuel is removed. 2. Replace drain plug if provided. 3. If any debris is noted in old fuel, add 1 or 2 quarts of clean kerosene to tank, stir, and drain again. This will prevent excess debris from clogging filters dur- ing future use. 4. Replace fuel cap or drain plug. Prop- erly dispose of old and dirty fuel. Check with local automotive service stations that recycle oil. 5. If storing, store heater in dry place. Make sure storage place is free of dust and corrosive fumes.

Item

How Often

How To

Flush every 150-200 hours of op- eration or as needed. Replace every 500 hours of, op- eration or once a year. Wash and dry with soap and water every 500 hours of operation or as needed. Clean twice a heating season or as needed. Clean and regap every 600 hours operation or replace as needed. Clean every season or as needed. Not required/permanently lubri- cated

See Storing, Transporting or Shipping,column 1 See Air Output, Air Intake, and Lint Filters, page 10. See Air Output, Air Intake, and Lint Filters, page 10.

Air output and lint filters Air intake filter

See Fuel Filter, page 8.

See Spark Plug, page 9.

See Fan, page 13.

Show 5 more labels / short text on this page
Fuel tank · Fuel filter · Spark plug · Fan blades Motor · 6 104468
Page 7 of the Master Lock B70CEA user manual — WARNING: High voltage!
Page 7 · click to enlarge
Page 7

TROUBLESHOOTING

OBSERVED FAULT

POSSIBLE CAUSE

REMEDY

Heater ignites, but flame-out control shuts off heater after a short period of time.

1. Wrong pump pressure
1. See Pump Pressure Adjustment , page 10. 2. See Air Output, Air Intake and Lint Filters , page 10. 3. See Fuel Filter , page 8. 4. See Nozzle , page 11. 5. Clean photocell lens. 6. Replace flame-out control.
2. Dirty air output, air intake, and lint filters
3. Dirty fuel filter 4. Dirt in nozzle 5. Dirty photocell lens 6. Bad flame-out control

Heater will not ignite, but motor runs for a short period of time.

1. Wrong pump pressure 2. Carbon deposits on spark plug and/or improper gap 3. Dirty fuel filter 4. Dirt in nozzle 5. Water in fuel tank
1. See Pump Pressure Adjustment, page 10. 2. See Spark Plug, page 9.
3. See Fuel Filter, page 8. 4. See Nozzle, page 11. 5. Drain and flush fuel tank with clean kerosene. See Storing, Transporting, or Shipping, page 6.

WARNING: High voltage!

6. Electronic ignitor not grounded (earthed)
6. Make sure electronic ignitor mounting is tight. 7. Replace electronic ignitor.
7. Bad electronic ignitor

Motor does not start when heater is plugged in, fan rotates slowly or does not turn.

1. Reset flame-out control button, see Figures 5 and 6, page 5. 2. If fan is hard to turn, see Pump Rotor ,
1. Flame-out control not reset
2. Binding pump rotor

page 12.

7 104468

Page 8 of the Master Lock B70CEA user manual — SERVICE PROCEDURES
Page 8 · click to enlarge
Page 8

SERVICE PROCEDURES

Upper Shell Removal 1. Remove screws and lock washers along each side of heater using 5/16" nut- driver. These screws attach upper and lower shells together. 2. Lift upper shell off. 3. Remove fan guard.

Figure 7 - Upper Shell Removal, 35/70,000 Btu/Hr Models Figure 8 - Upper Shell Removal, 100/ 150,000 Btu/Hr Models

Fuel Filter (35/70,000 Btu/Hr Models) 1. Remove side cover screws using 5/16" nut-driver. 2. Remove side cover. 3. Pull rubber fuel line off fuel filter neck. 4. Carefully pry bushing and fuel filter out of fuel tank. 5. Wash fuel filter with clean fuel and re- place in tank. 6. Attach rubber fuel line to fuel filter neck. 7. Replace side cover.

Figure 9 - Fuel Filter Removal, 35/70,000 Btu/Hr Models

Fuel Filter (100/150,000 Btu/Hr Models) 1. Remove side cover screws using 5/16" nut-driver. 2. Remove side cover. 3. Pull upper fuel line off fuel filter neck. 4. Carefully pry bushing, lower fuel line, and fuel filter out of fuel tank. 5. Wash fuel filter with clean fuel and re- place in tank. 6. Attach upper fuel line to fuel filter neck. 7. Replace side cover.

Master Lock B70CEA — SERVICE PROCEDURES diagram (page 8)
Fig. 4

Figure 10 - Fuel Filter Removal, 100/150,000 Btu/Hr Models

Show 10 more labels / short text on this page
Upper Shell · Upper Shell · Fan Guard · Fan Guard · Fuel Filter · Side Cover · Fuel Line · Upper Fuel Line · Side Cover · 8 104468
Page 9 of the Master Lock B70CEA user manual — SERVICE PROCEDURES Continued
Page 9 · click to enlarge
Page 9

SERVICE PROCEDURES Continued

Spark Plug (70/100/150,000 Btu/Hr Models) 1. Remove upper shell (see page 8). 2. Remove fan (see page 13). 3. Remove spark plug wire from spark plug. 4. Remove spark plug from burner head using 13/16" open-end wrench. 5. Clean and regap spark plug electrodes as follows: 70/100,000 Btu/Hr Models: 1.9 mm (.075") gap 150,000 Btu/Hr Model: 2.8 mm (.110") gap 6. Install spark plug in burner head. 7. Attach spark plug wire to spark plug. 8. Replace fan (see page 13). 9. Replace fan guard and upper shell.

Spark Plug Mounting Nut Spark Plug

Spark Plug (35,000 Btu/Hr Model) 1. Remove upper shell (see page 8). 2. Remove fan (see page 13). 3. Remove fuel and air line hoses from nozzle assembly. 4. Remove spark plug wire from spark plug. 5. Remove two screws using 5/16" nut- driver and remove burner strap. 6. Place hex-body of spark plug into vise and tighten. 7. Remove spark plug mounting nut us- ing 11/16" open-end wrench. 8. Remove burner strap from spark plug. 9. Clean and regap spark plug electrodes to 1.4 mm (.055") gap. 10. Replace burner strap onto spark plug. Rotate burner strap to position spark plug electrodes (see Figure 13). 11. Tighten spark plug with spark plug mounting nut. 12. Release hex-body of spark plug from vise. 13. Replace burner strap onto combustion chamber. 14. Attach spark plug wire to spark plug. 15. Attach fuel and air line hoses to nozzle assembly. 16. Replace fan (see page 13). 17. Replace fan guard and upper shell.

Fuel Line Hose Air Line Hose

Figure 11 - Spark Plug Removal, 35,000 Btu/Hr Model

Bend Here to Adjust Gap

1.4 mm (.055") Gap

Figure 12 - Spark Plug Gap, 35,000 Btu/Hr Model

Figure 14 - Spark Plug Removal, 70/100/ 150,000 Btu/Hr Models

Bend Here to Adjust Gap

Figure 13 - Spark Plug Rotation, 35,000 Btu/Hr Model Only

Figure 15 - Spark Plug Gap, 70/100/150,000 Btu/Hr Models

Show 11 more labels / short text on this page
Combustion Chamber · Burner Strap · Spark Plug Wire · Nozzle Assembly · Burner Head · Spark Plug Wire · Burner Strap · Spark Plug · Gap · Continued · 9 104468
Page 10 of the Master Lock B70CEA user manual — Model Pump Pressure
Page 10 · click to enlarge
Page 10

SERVICE PROCEDURES Continued

Air Output, Air Intake, and Lint Filters 1. Remove upper shell (see page 8). 2. Remove filter end cover screws using 5/16" nut-driver. 3. Remove filter end cover. 4. Replace air output and lint filters. 5. Wash or replace air intake filter (see Preventative Maintenance Schedule, page 6). 6. Replace filter end cover. 7. Replace fan guard and upper shell.

Figure 16 - Air Output, Air Intake, and Lint Filters, 35/70,000 Btu/Hr Models

Pump Pressure Adjustment 1. Remove pressure gauge plug from filter end cover. 2. Install accessory pressure gauge (part number HA1180). 3. Start heater (see Operation, page 5). Allow motor to reach full speed. 4. Adjust pressure. Turn relief valve to right to increase pressure. Turn relief valve to left to decrease pressure. See specifications at right for correct pres- sure for each model. 5. Remove pressure gauge. Replace pres- sure gauge plug in filter end cover.

Figure 17 - Air Output, Air Intake, and Lint Filters, 100/150,000 Btu/Hr Models

Master Lock B70CEA — SERVICE PROCEDURES Continued diagram (page 10)
Fig. 5 · SERVICE PROCEDURES Continued

Model Pump Pressure

(PSI/Bar)

35,000 Btu/Hr 2.9/0.20 70,000 Btu/Hr 3.8/0.26 100,000 Btu/Hr 3.9/0.27 150,000 Btu/Hr 4.8/0.33

Master Lock B70CEA — Model Pump Pressure diagram (page 10)
Fig. 6 · Model Pump Pressure

Figure 18 - Pressure Gauge Plug Removal

(35/70,000 Btu/Hr Models Shown)

Figure 19 - Adjusting Pump Pressure

Show 13 more labels / short text on this page
Air Intake Filter · Filter End Cover · Fan Guard · Lint Filter · Air Output Filter · Air Intake Filter · Filter End Cover · Fan Guard · Lint Filter · Air Output Filter · Pressure Gauge Plug · Relief Valve · 10 104468
Page 11 of the Master Lock B70CEA user manual — SERVICE PROCEDURES Continued
Page 11 · click to enlarge
Page 11

SERVICE PROCEDURES Continued

11. Replace nozzle into burner head and tighten firmly (9.1-12.4 n-m/80-110 inch-pounds). 12. Attach burner head to combustion chamber. 13. Install spark plug in burner head. 14. Attach spark plug wire to spark plug. 15. Attach fuel and airline hoses to burner head. 16. Replace fan (see page 13). 17. Replace fan guard and upper shell.

Nozzle (35,000 Btu/Hr Model) 1. Remove upper shell (see page 8). 2. Remove fan (see page 13). 3. Remove fuel and air line hoses from nozzle assembly. 4. Turn nozzle assembly 1/4 turn to left and pull toward motor to remove. 5. Place plastic hex-body into vise and lightly tighten. 6. Carefully remove nozzle from the nozzle adapter using 5/8" socket wrench. 7. Blow compressed air thru face of nozzle. This will free any dirt in nozzle area. 8. Inspect nozzle seal for damage. 9. Replace nozzle into nozzle adapter un- til nozzle seats. Tighten 1/3 turn more using 5/8" socket wrench (4.5-5.1 n-m/ 40-45 inch-pounds). 10. Attach nozzle assembly to burner strap. 11. Attach fuel and airline hoses to nozzle assembly. 12. Replace fan (see page 13). 13. Replace fan guard and upper shell.

Combustion Chamber Burner Head

Figure 21 - Removing Nozzle Assembly, 35,000 Btu/Hr Model

Figure 23 - Removing Burner Head, 70/100/150,000 Btu/Hr Models

Figure 22 - Nozzle and Nozzle Adapter, 35,000 Btu/Hr Model

Nozzle (70/100/150,000 Btu/Hr Models) 1. Remove upper shell (see page 8). 2. Remove fan (see page 13). 3. Remove fuel and air line hoses from burner head. 4. Remove spark plug wire from spark plug. 5. Remove spark plug from burner head using 13/16" open-end wrench. 6. Remove three screws using 5/16" nut- driver and remove burner head from combustion chamber. 7. Place burner head into vise and lightly tighten. 8. Carefully remove nozzle from burner head using 5/8" socket wrench (see Fig- ure 24). 9. Blow compressed air thru face of nozzle. This will free any dirt in nozzle area. 10. Inspect nozzle seal for damage.

Figure 24 - Removing Nozzle, 70/100/ 150,000 Btu/Hr Models

Fuel Line Hose Air Line Hose

Figure 20 - Removing Air and Fuel Line Hoses, 35,000 Btu/Hr Model

Show 23 more labels / short text on this page
Burner Strap · Nozzle Assembly · Spark Plug Wire · Nozzle Face · Screw · Nozzle Seal · Spark Plug · Nozzle · Nozzle Adapter · Fuel Line Hose · Air Line Hose · Air line Fitting · Fuel line Fitting · Nozzle Face · Nozzle Seal · Combustion Chamber · Nozzle · Burner Head · Fuel line Fitting · Air line Fitting · Nozzle Assembly · Continued · 11 104468
Page 12 of the Master Lock B70CEA user manual — SERVICE PROCEDURES Continued
Page 12 · click to enlarge
Page 12

SERVICE PROCEDURES Continued

Master Lock B70CEA — SERVICE PROCEDURES Continued diagram (page 12)
Fig. 7 · SERVICE PROCEDURES Continued

Pump Rotor (Procedure if rotor is binding) 1. Remove upper shell (see page 8). 2. Remove filter end cover screws using 5/16" nut-driver. 3. Remove filter end cover and air filters. 4. Remove pump plate screws using 5/16" nut-driver. 5. Remove pump plate. 6. Remove rotor, insert, and blades. 7. Check for debris in pump. If debris is found, blow out with compressed air. 8. Install insert and rotor. 9. Check gap on rotor. Adjust to .076/.101 mm (.003"/.004") if needed (see Fig- ure 27).

Figure 25 - Rotor Location, 35/70,000 Btu/Hr Models

Master Lock B70CEA — SERVICE PROCEDURES Continued diagram (page 12)
Fig. 8 · SERVICE PROCEDURES Continued

Figure 26 - Rotor Location, 100/150,000 Btu/Hr Models

Master Lock B70CEA — SERVICE PROCEDURES Continued diagram (page 12)
Fig. 9 · SERVICE PROCEDURES Continued

.076/.101 mm (.003"/.004") Gap Measured With Feeler Gauge

Figure 28 - Sanding Rotor Figure 27 - Gap Adjusting Screw Locations

Show 6 more labels / short text on this page
Fan Guard · Fan Guard · Sandpaper · Blade · Gap Adjusting Screw · 12 104468
Page 13 of the Master Lock B70CEA user manual — B
Page 13 · click to enlarge
Page 13

SERVICE PROCEDURES Continued

SPECIFICATIONS

Output Rating (Btu/Hr) 35,000 70,000 100,000 150,000

Fuel Use Only Kerosene or No. 1 Fuel Oil

Fan

IMPORTANT: Remove fan from motor shaft before removing motor from heater. The weight of the motor resting on the fan could damage the fan pitch. 1. Remove upper shell (see page 8). 2. Use 1/8" allen wrench to loosen set- screw which holds fan to motor shaft. 3. Slip fan off motor shaft. 4. Clean fan using a soft cloth moistened with kerosene or solvent. 5. Dry fan thoroughly. 6. Replace fan on motor shaft. Place fan hub flush with end of motor shaft (see Figure 30). 7. Place setscrew on flat of shaft. Tighten setscrew firmly (40-50 inch-pounds/ 4.5-5.6 n-m). 8. Replace fan guard and upper shell.

(U.S. Gal./Liters) 3.0/11.4 5.0/18.9 9.0/34 13.5/51.1

(Gal. Per Hr./Liters Per Hr.) .26/1.0 .49/1.85 .70/2.7 1.1/4.1

Electric Requirements 230 V/50 Hz (Same All Models)

Amperage (Normal Run) .8 1.0 1.2 1.2

Hot Air Output (CFM/CMM) 140/4 225/6.4 425/12 500/14.2

RPM 1425 2850 2850 2850

WIRING DIAGRAMS

B

Figure 31 - Wiring Diagram, 35/100/150,000 Btu/Hr Models

Figure 29 - Fan, Motor Shaft, and Setscrew Location

B

Black S or 2 M or 5

Figure 30 - Fan Cross Section

Figure 32 - Wiring Diagram, 70,000 Btu/Hr Model

Show 56 more labels / short text on this page
Fuel Tank Capacity · Fuel Consumption · 230V/50Hz · Brown Blue · RFI Filter · Black · Black · Green/Yellow · White · White · Spark Plug Flame- · Fan · Orange Terminal · Ignitor White · Blue · Blue · Reset Button · Setscrew · Board Motor · Out Control · Photocell · Green/ Yellow · Red · R Red · Red · 230V/50Hz · Motor Shaft · Brown Blue · RFI Filter · Black · Black · Green/Yellow · White · White · Fan · Spark Plug Flame- · Orange Terminal · Ignitor White · Blue · Blue · Reset Button · Board Motor · Out Control · Photocell · Flush · Green/ Yellow · Red · R Red · Motor Shaft · Red · Red · Motor · Setscrew · Start Relay · L or 1 · 13 104468
Page 14 of the Master Lock B70CEA user manual — SPECIFICATIONS
Page 14 · click to enlarge
Page 14
Master Lock B70CEA — SPECIFICATIONS diagram (page 14)
Fig. 10

Motor and Pump Assembly

14 104468

Page 15 of the Master Lock B70CEA user manual — PARTS AVAILABLE - NOT SHOWN
Page 15 · click to enlarge
Page 15

This list contains replaceable parts used in your heater. When ordering parts, be sure to provide the correct model and serial numbers (from the model plate), then the part number and description of the desired part. PARTS LIST

KEY PART PART NO. NUMBER DESCRIPTION QTY.

KEY PART PART NO. NUMBER DESCRIPTION QTY.

1 M51104-01 Handle 1 2 098511-54 Upper Shell 1 3 102432-01 Screw/Lockwasher, 1/2" 6 4 098512-43 Combustion Chamber 1 5 M51108-01 Heat Shield 1 6 M11084-29 Screw, #10-16 x 3/4" 2 7 M16660 Photocell Bracket 1 8 M10908-2 Screw, #6-32 x 3/8" 2 9 HA3019 Photocell Assembly 1 10 079673-06 Power Cord 1 11 ** Burner Strap Assembly 1 11-1 097124-01 Bracket 1 11-2 HA3013 Spark Plug 1 11-3 079980-01 Nozzle Adapter 1 11-4 M29824 Nut, 14mm 1 11-5 HA3006 Nozzle 1 12 102801-01 Power Line RFI Filter 1 13 M30865-02 Bushing 2 14 M50400 Strain Relief Bushing 1 15 M30884 Fan 1 16 M50631 Rubber Bumper 2 17 101205-01 Motor Bracket 1 18 ** Motor and Pump Assembly 1 18-1 098642-02 Motor (230V/50Hz) 1 18-2 079975-03 Pump Body 1 18-3 M22009 Insert 1 18-4 M22456-2 Rotor 1 18-5 M29608 End Pump Cover 1 18-6 M29632 Lint Filter 1 18-7 M29633 Intake Filter 1 18-8 M29609 End Filter Cover 1 18-9 M12461-31 Screw, #10-32 x 1" 3 18-10 M8940 Steel Ball (1/4" Dia.) 1 18-11 M10993-1 Pressure Relief Spring 1 18-12 M27694 Adjusting Screw 1 18-13 M22997 Plug 1 18-14 M29612-01 Output Filter 1 18-15 M12461-32 Screw, #10-32 x 1 1/8" 6

18-16 M50016 Elbow, 90˚ (Barb Fitting) 1 18-17 M8643-2 Blade 4 18-18 FHPF3-6C Screw, #10-32 x 3/4" 2 19 M51105-01 Fan Guard 1 20 NTC-4C Hex locknut 2 21 M50104-02 Bushing (wires) 2 22 102431-01 Screw/Lockwasher, 1/2" 10 23 098511-12 Lower Shell 1 24 M11271-8 Clip Nut 6 25 RF3-6B Screw, #10-32 x 3/4" 1 26 M29652-04 Rubber Airline 1 27 M29652-05 Fuel Line 1 28 M16841-57 Wire Assembly (red 8 1/2") 1 29 M10990-3 Rubber Bushing 1 30 M50876-04 Fuel Filter Assembly 1 (Includes bushing) 31 102482-02 Electronic Ignitor 1 32 M11084-29 Screw, #10-16 x 3/4" 2 33 099125-02 Terminal Board 1 34 099157-01 Rivet 1 35 097630-02 Flame-Out Control 1 36 097702-01 Fuel Tank Cap 1 37 098513-73 Fuel Tank 1 38 M50899-03AA Side Cover 1 39 NPF-3B Nut, #10-32 3 40 099177-01 Hex Nut 1 41 078918-01 Terminal Board Tab Cap 1 42 097785-01 Vinyl Foam Gasket 1 43 WLE-3 Lock Washer, #10 2

PARTS AVAILABLE - NOT SHOWN

HA2210 Filler Neck Screen 1 097649-01 Tradename Decal 2 M9900-192 Combustion Chamber Ground Wire 1 102944-01 Decal Package 1

**Not available as an assembly, order parts separately.

15 104468

Page 16 of the Master Lock B70CEA user manual — PARTS AVAILABLE - NOT SHOWN
Page 16 · click to enlarge
Page 16
Master Lock B70CEA — PARTS AVAILABLE - NOT SHOWN diagram (page 16)
Fig. 11

16 104468

Page 17 of the Master Lock B70CEA user manual — PARTS AVAILABLE - NOT SHOWN
Page 17 · click to enlarge
Page 17

PARTS LIST

This list contains replaceable parts used in your heater. When ordering parts, be sure to provide the correct model and serial numbers (from the model plate), then the part number and description of the desired part.

KEY PART PART NO. NUMBER DESCRIPTION QTY.

KEY PART PART NO. NUMBER DESCRIPTION QTY.

1 M51104-01 Handle 1 2 098511-54 Upper Shell 1 3 102432-01 Screw/Lockwasher, 1/2" 6 4 098512-44 Combustion Chamber 1 5 M11084-29 Screw, #10-16 x 3/4" 2 6 M16660 Photocell Bracket 1 7 M10908-2 Screw, #6-32 x 3/8" 2 8 HA3019 Photocell Assembly 1 9 079673-06 Power Cord 1 10 ** Burner Head Assembly 1 10-1 HA3008 Nozzle 1 10-2 M10659-1 Nozzle Seal Washer 2 10-3 M10809-1 Nozzle Seal Spring 1 10-4 M8882 Nozzle Seal Sleeve 1 10-5 M51098-02 Burner Head Body 1 10-6 M50820-01 Barb Fitting 2 10-7 HA3012 Spark Plug 1 11 102431-01 Screw/Lockwasher, 1/2" 11 12 M30865-02 Bushing 2 13 M50400 Strain Relief Bushing 1 14 M30884 Fan 1 15 M50631 Rubber Bumper 2 16 M12461-13 Screw, #8-32 x 1/4" 2 (holds relay in position) 17 101205-01 Motor/Relay Bracket 1 18 ** Motor and Pump Assembly 1 18-1 102001-16 Motor (230V/50Hz) 1 18-2 079975-02 Pump Body 1 18-3 M22009 Insert 1 18-4 M22456-1 Rotor 1 18-5 M29608 End Pump Cover 1 18-6 M29632 Lint Filter 1 18-7 M29633 Intake Filter 1 18-8 M29609 End Filter Cover 1 18-9 M12461-31 Screw, #10-32 x 1" 3 18-10 M8940 Steel Ball (1/4" Dia.) 1 18-11 M10993-1 Pressure Relief Spring 1 18-12 M27694 Adjusting Screw 1 18-13 M22997 Plug 1 18-14 M29612-01 Output Filter 1

18-15 M12461-31 Screw, #10-32 x 1" 6 18-16 M50016 Elbow, 90˚ (Barb Fitting) 1 18-17 M8643 Blade 4 18-18 FHPF3-5C Screw, #10-32 x 5/8" 2 19 M51105-01 Fan Guard 1 20 NTC-4C Hex locknut 2 21 M50104-02 Bushing (wires) 2 22 102801-01 Power Line RFI Filter 1 23 098511-12 Lower Shell 1 24 M11271-8 Clip Nut 6 25 098136-05 Relay (motor start) 1 26 M16841-58 Wire Assembly (red 9 1/2") 1 27 RF3-6B Screw, #10-32 x 3/4" 1 28 M29652-04 Rubber Airline 1 29 079973-01 Fuel Line 1 30 M16841-57 Wire Assembly (red 8 1/2") 1 31 M10990-3 Rubber Bushing 1 32 M50876-05 Fuel Filter Assembly 1 (Includes bushing) 33 102482-02 Electronic Ignitor 1 34 M11084-29 Screw, #10-16 x 3/4" 2 35 099125-02 Terminal Board 1 36 099157-01 Rivet 1 37 097702-01 Fuel Tank Cap 1 38 097630-02 Flame-Out Control 1 39 098513-74 Fuel Tank 1 40 M50899-03AA Side Cover 1 41 NPF-3B Nut, #10-32 3 42 099177-01 Hex Nut 1 43 078918-01 Terminal Board Tab Cap 1 44 097785-01 Vinyl Foam Gasket 1 45 WLE-3 Lock Washer, #10 2

PARTS AVAILABLE - NOT SHOWN

HA2210 Filler Neck Screen 1 097649-01 Tradename Decal 2 M9900-192 Combustion Chamber Ground Wire 1 102944-02 Decal Package 1

**Not available as an assembly, order parts separately.

17 104468

Page 18 of the Master Lock B70CEA user manual — PARTS LIST
Page 18 · click to enlarge
Page 18
Master Lock B70CEA — PARTS LIST diagram (page 18)
Fig. 12

18 104468

Page 19 of the Master Lock B70CEA user manual — PARTS AVAILABLE - NOT SHOWN
Page 19 · click to enlarge
Page 19

PARTS LIST

This list contains replaceable parts used in your heater. When ordering parts, be sure to provide the correct model and serial numbers (from the model plate), then the part number and description of the desired part.

KEY PART PART NO. NUMBER DESCRIPTION QTY.

KEY PART PART NO. NUMBER DESCRIPTION QTY.

1 098511-138 Upper Shell 1 2 102432-01 Screw/Lockwasher, 1/2" 8 3 098512-31 Combustion Chamber 1 4 M16660 Photocell Bracket 1 5 HA3019 Photocell Assembly 1 6 M27417 Drain Plug 1 7 M10908-2 Screw, #6-32 x 3/8" 2 8 ** Burner Head Assembly 1 8-1 100735-15 Nozzle 1 8-2 M10659-1 Nozzle Seal Washer 2 8-3 M10809-1 Nozzle Seal Spring 1 8-4 M8882 Nozzle Seal Sleeve 1 8-5 M50924-03 Burner Head Body 1 8-6 M50820-02 Barb Fitting 2 8-7 HA3012 Spark Plug 1 9 102431-01 Screw/Lockwasher, 1/2" 13 10 M50814-06 Air Line 1 11 M51345-01 Fuel Line 1 12 102042-01 Fan 1 13 ** Motor and Pump Assembly 1 13-1 102001-03 Motor with capacitor (230V/50Hz) 1 13-2 079975-02 Pump Body 1 13-3 FHPF3-5C Screw, #10-32 x 5/8" 2 13-4 M22009 Insert 1 13-5 M22456-1 Rotor 1 13-6 M50545 End Pump Cover 1 13-7 M12179 Intake Filter 1 13-8 M16545 End Filter Cover 1 13-9 M8940 Steel Ball (1/4" Dia.) 1 13-10 M10993-1 Pressure Relief Spring 1 13-11 M27694 Adjusting Screw 1 13-12 M22997 Plug 1 13-13 M12461-31 Screw, #10-32 x 1" 4 13-14 M12244-1 Output Filter 1 13-15 M12461-31 Screw, #10-32 x 1" 6 13-16 M11637 Lint Filter 1 13-17 M50820-02 Barb Fitting 1 13-18 M8643 Blade 4 14 M51114-01 Fan Guard 1

15 M50631 Rubber Bumper 2 16 097468-01 Edge Liner 1 17 101206-01 Motor and Relay Bracket Assembly 1 18 WLE-3 Lock Washer, #10 2 19 NPF-3B Nut, #10-32 3 20 NTC-4C Hex locknut 2 21 102482-02 Electronic Ignitor 1 22 M11084-29 Screw, #10-16 x 3/4" 2 23 099125-02 Terminal Board 1 24 099157-01 Rivet 1 25 M50104-03 Bushing 1 26 M50104-03 Bushing 1 27 M50104-01 Bushing 2 28 099213-01 Button Plug 1 29 102801-01 Power Line RFI Filter 1 30 098511-191 Lower Shell 1 31 M11271-8 Clip Nut 8 32 RF3-6B Screw, #10-32 x 3/4" 1 33 M51150-01 Fuel filter 1 34 M10990-3 Rubber Bushing 1 35 M51151-01 Fuel Line 1 36 098513-75 Fuel Tank 1 37 097702-01 Fuel Tank Cap 1 38 M16841-57 Wire Assembly (red 8 1/2") 1 39 097630-02 Flame-Out Control 1 40 M50400 Strain Relief Bushing 1 41 079673-06 Power Cord 1 42 M51077-01AA Side Cover 1 43 099177-01 Hex Nut 1 44 078918-01 Terminal Board Tab Cap 1

PARTS AVAILABLE - NOT SHOWN

HA2210 Filler Neck Screen 1 097650-01 Tradename Decal 2 M9900-192 Combustion Chamber Ground Wire 1 102944-03 Decal Package 1

**Not available as an assembly, order parts separately.

19 104468

Page 20 of the Master Lock B70CEA user manual — PARTS LIST
Page 20 · click to enlarge
Page 20
Master Lock B70CEA — PARTS LIST diagram (page 20)
Fig. 13

20 104468

Page 21 of the Master Lock B70CEA user manual — PARTS AVAILABLE - NOT SHOWN
Page 21 · click to enlarge
Page 21

PARTS LIST

This list contains replaceable parts used in your heater. When ordering parts, be sure to provide the correct model and serial numbers (from the model plate), then the part number and description of the desired part.

KEY PART PART NO. NUMBER DESCRIPTION QTY.

KEY PART PART NO. NUMBER DESCRIPTION QTY.

1 098511-138 Upper Shell 1 2 102432-01 Screw/Lockwasher, 1/2" 8 3 098512-36 Combustion Chamber 1 4 099229-01 Photocell Bracket 1 5 HA3019 Photocell Assembly 1 6 M27417 Drain Plug 1 7 M10908-2 Screw, #6-32 x 3/8" 2 8 ** Burner Head Assembly 1 8-1 100735-11 Nozzle 1 8-2 M10659-1 Nozzle Seal Washer 2 8-3 M10809-1 Nozzle Seal Spring 1 8-4 M8882 Nozzle Seal Sleeve 1 8-5 M50924-08 Burner Head Body 1 8-6 M50820-02 Barb Fitting 2 8-7 HA3012 Spark Plug 1 9 102431-01 Screw/Lockwasher, 1/2" 9 10 M50814-06 Air Line 1 11 M51345-01 Fuel Line 1 12 102042-01 Fan 1 13 ** Motor and Pump Assembly 1 13-1 102001-03 Motor (with capacitor) 1 13-2 079975-03 Pump Body 1 13-3 FHPF3-6C Screw, #10-32 x 3/4" 2 13-4 M22009 Insert 1 13-5 M22456-2 Rotor 1 13-6 M50545 End Pump Cover 1 13-7 M12179 Intake Filter 1 13-8 M16545 End Filter Cover 1 13-9 M8940 Steel Ball (1/4" Dia.) 1 13-10 M10993-1 Pressure Relief Spring 1 13-11 M27694 Adjusting Screw 1 13-12 M22997 Plug 1 13-13 M12461-31 Screw, #10-32 x 1" 4 13-14 M12244-1 Output Filter 1 13-15 M12461-32 Screw, #10-32 x 1 1/8" 6 13-16 M11637 Lint Filter 1 13-17 M50820-02 Barb Fitting 1 13-18 M8643-2 Blade 4 14 M51114-01 Fan Guard 1 15 M50631 Rubber Bumper 2

16 097468-01 Edge Liner 1 17 101206-01 Motor Bracket 1 18 WLE-3 Lock Washer, #10 2 19 NPF-3B Nut, #10-32 3 20 NTC-4C Hex locknut 2 21 102482-02 Electronic Ignitor 1 22 M11084-29 Screw, #10-16 x 3/4" 2 23 099125-02 Terminal Board 1 24 099157-01 Rivet 1 25 M50104-03 Bushing 1 26 M50104-03 Bushing 1 27 M50104-01 Bushing 2 28 099213-01 Button Plug 1 29 102801-01 Power Line RFI Filter 1 30 098511-191 Lower Shell 1 31 M11271-8 Clip Nut 8 32 RF3-6B Screw, #10-32 x 3/4" 1 33 M51150-01 Fuel filter 1 34 M10990-3 Rubber Bushing 1 35 M51151-02 Fuel Line 1 36 098513-76 Fuel Tank 1 37 097702-01 Fuel Tank Cap 1 38 M16841-57 Wire Assembly (red 8 1/2") 1 39 097630-02 Flame-Out Control 1 40 M50400 Strain Relief Bushing 1 41 079673-06 Power Cord 1 42 M51077-01AA Side Cover 1 43 M11084-27 Screw, #10-16 x 1/2" 4 44 078918-01 Terminal Board Tab Cap 1 45 099177-01 Hex Nut 1 46 097785-04 Vinyl Foam Gasket 2

PARTS AVAILABLE - NOT SHOWN

HA2210 Filler Neck Screen 1 097650-01 Tradename Decal 2 M9900-192 Combustion Chamber Ground Wire 1 102944-04 Decal Package 1

**Not available as an assembly, order parts separately.

21 104468

Page 22 of the Master Lock B70CEA user manual — PARTS LIST
Page 22 · click to enlarge
Page 22
Master Lock B70CEA — PARTS LIST diagram (page 22)
Fig. 14

KEY PART PART 100,000 150,000 NO. NUMBER DESCRIPTION QTY. QTY.

1 HA2203 Handles 2 — HA2204 Handles — 2 2 M12345-33 Screw, #10-24 x 1 3/4" 8 8 3 M12342-3 Wheel Support Frame 1 — M12831-3 Wheel Support Frame — 1 4 NTC-3C Hex Nut, #10-24 8 8 5 097896-03 Wheel 2 2 6 M28526 Cap Nut 2 2 7 M51015-01 Axle 1 — M16801-2 Axle — 1

Master Lock B70CEA — PARTS LIST diagram (page 22)
Fig. 15

22 104468

Page 23 of the Master Lock B70CEA user manual — HEAVY DUTY WHEELS AND HANDLE KIT - HA1202
Page 23 · click to enlarge
Page 23

ACCESSORIES

Purchase accessories from your local dealer.

AIR GAUGE KIT - HA1180

For all models. Special tool to check pump pressure. STANDARD WHEELS AND HANDLE KIT - HA1206

Makes heater even more portable and conve- nient. Easy to assemble.

For 35/70,000 Btu/Hr models.

HEAVY DUTY WHEELS AND HANDLE KIT - HA1202

For heavy duty applications. Makes your heater even more portable and convenient.

For 35/70,000 Btu/Hr models.

23 104468

Page 24 of the Master Lock B70CEA user manual — WARRANTY SERVICE
Page 24 · click to enlarge
Page 24

WARRANTY AND REPAIR SERVICE

CERTIFICATE OF GENERAL EQUIPMENT - LIMITED 90 DAY WARRANTY

DESA International warrants new Products sold by it to be free from defects in material or workmanship for a period of ninety days after date of delivery to the first user and subject to the following conditions:

POSE. IN ANY EVENT IMPLIED WARRANTIES INCLUDING THOSE OF MERCHANTABILITY AND FITNESS FOR A PAR- TICULAR PURPOSE ARE LIMITED TO THE DURATION OF THIS EXPRESS WARRANTY.

DESA International's obligation and liability under this Warranty is expressly limited to repairing or replacing at DESA International's option, any parts which appear to DESA Interna- tional upon inspection to have been defective in material or workmanship when shipped from the factory. Such parts shall be provided at no cost to the user, at the business establishment of any factory authorized service center or the factory during regular working hours. The Warranty shall not apply to compo- nent parts or accessories of Products not manufactured by DESA International and which carry the warranty of the manu- facturer thereof, or to normal maintenance (such as pressure adjustments) or to normal maintenance parts (such as filters and spark plugs). Replacement or repair parts installed in the Product covered by this Warranty are warranted only for the remainder of this Warranty as if such parts were original compo- nents of said Product. DESA INTERNATIONAL MAKES NO OTHER EXPRESS WARRANTY. TO THE EXTENT PERMIT- TED BY LAW DESA INTERNATIONAL MAKES NO IMPLIED WARRANTY AND MAKES NO WARRANTY OF MER- CHANTABILITY OR FITNESS FOR ANY PARTICULAR PUR-

Any transportation charges, costs of installation, duty, taxes or any other charges whatsoever must be borne by the user. DESA International's obligation under this limited War- ranty shall not include any liability for direct, indirect, incidental, or consequential damage or delay. If requested by DESA International, Products or parts for which a warranty claim is made are to be returned transportation prepaid by user to the factory. Any improper use, including operation after discovery of defective or worn parts, operation beyond capacity, substi- tution of parts not approved by DESA International, or any alteration or repair by others in such manner as in DESA International's judgement affects the Product materially and adversely, shall void this Warranty.

NO EMPLOYEE OR REPRESENTATIVE IS AUTHORIZED TO CHANGE THIS WARRANTY IN ANY WAY OR GRANT ANY OTHER WARRANTY UNLESS SUCH CHANGE IS MADE IN WRITING AND SIGNED BY AN OFFICER OF DESA INTERNATIONAL AT ITS HOME OFFICE.

WARRANTY SERVICE

Always specify model and serial numbers when communicating with the factory.

We reserve the right to amend these specifications at any time without notice. The only Warranty applicable is our standard written Warranty. We make no other Warranty, expressed or implied.

A Service Manual is available by writing to the Technical Service Department at:

Corporate Headquarters 2701 Industrial Drive P.O. Box 90004 Bowling Green, Kentucky 42102-9004 U.S.A.

Printed in U.S.A.

Ask about the Master Lock B70CEA

Owners and our team usually reply within a day — and your question helps the next person too.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
No questions yet about the Master Lock B70CEA

Be the first to ask — other owners or our team will answer.

Original document

Master Lock B70CEA manual PDF

48 pages·1.2 MB·Air Conditioner·PDF
Click any page above to open it here
Page 1 / …
100%
Loading pages…