EN
Marantz logo
Official user manual

Marantz PMD505

17 pages·492 KB·Stereo System·PDF·ENDEFRITNLJA
Marantz PMD505
Table of Contents 80 sections Model PMD505 User Guide · Cassette Deck · IMPORTANT TO SAFETY · FOR U.S.A. & CANADA MODEL ONLY · … ShowHide
Model PMD505 User Guidep.1Cassette Deckp.1IMPORTANT TO SAFETYp.2 FOR U.S.A. & CANADA MODEL ONLYp.2WARNING:p.2CAUTIONp.2CAUTION:p.2 POUR LES MODELES AMERICAINS ET CANADIENS UNIQUEMENTp.2ATTENTIONp.2PRECAUCIÓNp.2RISK OF ELECTRIC SHOCKp.2DO NOT OPENp.2IMPORTANT SAFETYp.3INSTRUCTIONSp.3READ BEFORE OPERATING EQUIPMENTp.3AC POLARIZED PLUGp.3ANTENNA LEAD IN WIREp.4GROUND CLAMPp.4ANTENNA DISCHARGE UNIT (NEC SECTION 810-20)p.4ELECTRIC SERVICE EQUIPMENTp.4GROUNDING CONDUCTORS (NEC SECTION 810-21)p.4GROUND CLAMPSp.4NEC - NATIONAL ELECTRICAL CODEp.4– TABLE OF CONTENTS –p.6FEATURESp.6CONNECTIONp.6PMD505p.6NAMES AND FUNCTIONS OF PARTSp.7r !5 o !2e y eu !3 !1 op.7q t w i u w !0 !4p.7a Peak Level Meterp.8dB – 30 20 10 8 3 0 3 +6 Rp.8b Direction & Pause Indicatorsp.8c Multi Counterp.8d SYNC REV Indicatorp.8e Mode Indicatorsp.8f Dubbing Indicatorsp.8a b b d c e f c ep.8CASSETTE TAPESp.8PLAYBACKp.9r ep.9q w u y tp.9q ep.9RECORDING (DECK B only)p.10!0 e otp.10q w u y i u rp.10REC PLAYp.10DOLBY NRp.10OFFp.10PROPER RECORDING LEVELp.10REC MUTE AND REC PAUSE BUTTONp.10DUBBING (from deck A to deck B)p.11w tp.11q u y rp.11REV. MODEp.11SYNCHRO REVERSE DUBBINGp.11e rp.11q u y ip.11SYNCHRO RECORDING PROCEDURE (Deck B)p.12TAPE COUNTERp.12DOLBY B AND C NOISE REDUCTION SYSTEMp.12DOLBY HX PRO HEADROOM EXTENSION SYSTEMp.12MAINTENANCEp.13 CAPABILITY OF REMOTE CONTROLp.13RC-5 CODEp.13DECK A DECK B DIRECTION ( )p.13REMOTE CONTROLp.14USING THE REMOTE CONTROL UNITp.14x (REC PAUSE) button:p.14c REC button:p.14⁄0 (STOP) button:p.14TROUBLESHOOTINGp.15SPECIFICATIONSp.15Limited Warrantyp.16Limitation of Implied Warrantiesp.16Exclusion of Damagesp.16How State Law Relates to the Warrantyp.16Marantz Professional Service Number:p.16Non-Transferable Warrantyp.16What We Will Pay Forp.16
Page 1 of the Marantz PMD505 user manual — R
Page 1 · click to enlarge
Page 1

Model PMD505 User Guide

Cassette Deck

R

Page 2 of the Marantz PMD505 user manual — RISK OF ELECTRIC SHOCK
Page 2 · click to enlarge
Page 2

IMPORTANT TO SAFETY

FOR U.S.A. & CANADA MODEL ONLY

WARNING:

CAUTION

TO PREVENT FIRE OR SHOCK HAZARD, DO NOT EXPOSE THIS APPLIANCE TO RAIN OR MOISTURE.

TO PREVENT ELECTRIC SHOCK DO NOT USE THIS (POLARIZED) PLUG WITH AN EXTENSION CORD, RECEPTACLE OR OTHER OUTLET UNLESS THE BLADES CAN BE FULLY INSERTED TO PREVENT BLADE EXPOSURE.

CAUTION:

1. Handle the power supply cord carefully Do not damage or deform the power supply cord. If it is damaged or deformed, it may cause electric shock or malfunction when used. When removing it from wall outlet, be sure to remove by holding the plug attachment and not by pulling the cord. 2. Do not open the top cover In order to prevent electric shock, do not open the top cover. If problems occur, contact your MARANTZ DEALER. 3. Do not place anything inside Do not place metal objects or spill liquid inside the cassette tape deck. Electric shock or malfunction may result.

POUR LES MODELES AMERICAINS ET CANADIENS UNIQUEMENT

ATTENTION

POUR PREVENIR LES CHOCS ELECTRIQUES NE PAS UTILISER CETTE FICHE POLARISEE AVEC UN PROLONGATEUR UNE PRISE DE COURANT OU UNE AUTRE SORTIE DE COURANT, SAUF SI LES LAMES PEUVENT ETRE INSEREES A FOND SANS EN LAISSER AUCUNE PARTIE A DECOUVERT.

Please, record and retain the Model name and serial number of your set shown on the rating label. Model No. PMD505 Serial No.

PARA EL MODELO DESTINADO A LOS EE.UU. Y A CANADÁ

PRECAUCIÓN

PARA IMPEDIR LAS DESCARGAS ELÉCTRICAS NO UTILICE ESTA CLAVIJA POLARIZADA CON UN CABLE DE EXTENSIÓN, UNA TOMA DE CORRIENTE O UNA SALIDA DE CORRIENTE A MENOS QUE LAS PATILLAS PUEDAN INSERTARSE COMPLETAMENTE.

CAUTION

RISK OF ELECTRIC SHOCK

DO NOT OPEN

The lightning flash with arrowhead symbol within an equilateral triangle is intended to alert the user of the persence of uninsulated “dangerous voltage” within the product’s enclosure that may be of sufficient magnitude to constitute a risk of electric shock to persons.

The exclamation point within an equilateral triangle is intended to alert the user of the persence of important operating and maintenance (servicing) instruction in the literature accompanying the appliance.

Page 3 of the Marantz PMD505 user manual — AC POLARIZED PLUG
Page 3 · click to enlarge
Page 3

IMPORTANT SAFETY

INSTRUCTIONS

READ BEFORE OPERATING EQUIPMENT

This product was designed and manufactured to meet strict quality and safety standards. There are, however, some installation and operation precautions which you should be particularly aware of.

12. Grounding or Polarization – This product may be equipped with a polarized alternating-current line plug (a plug having one blade wider than the other). This plug will fit into the power outlet only one way. This is a safety feature. If you are unable to insert the plug fully into the outlet, try reversing the plug. If the plug should still fail to fit, contact your electrician to replace your obsolete outlet. Do not defeat the safety purpose of the polarized plug.

1. Read Instructions – All the safety and operating instructions should be read before the product is operated.
2. Retain Instructions – The safety and operating instructions should be retained for future reference.
3. Heed Warnings – All warnings on the product and in the operating instructions should be adhered to.
4. Follow Instructions – All operating and use instructions should be followed.

AC POLARIZED PLUG

5. Cleaning – Unplug this product from the wall outlet before cleaning. Do not use liquid cleaners or aerosol cleaners. Use a damp cloth for cleaning.
13. Power-Cord Protection – Power-supply cords should be routed so that they are not likely to be walked on or pinched by items placed upon or against them, paying particular attention to cords at plugs, convenience receptacles, and the point where they exit from the product.
6. Attachments – Do not use attachments not recommended by the product manufacturer as they may cause hazards.
7. Water and Moisture – Do not use this product near water-for example, near a bath tub, wash bowl, kitchen sink, or laundry tub, in a wet basement, or near a swimming pool, and the like.
14. Protective Attachment Plug – The product is equipped with an attachment plug having overload protection. This is a safety feature. See Instruction Manual for replacement or resetting of protective device. If replacement of the plug is required, be sure the service technician has used a replacement plug specified by the manufacturer that has the same overload protection as the original plug.
8. Accessories – Do not place this product on an unstable cart, stand, tripod, bracket, or table. The product may fall, causing serious injury to a child or adult, and serious damage to the product. Use only with a cart, stand, tripod, bracket, or table recommended by the manufacturer, or sold with the product. Any mounting of the product should follow the manufacturer’s instructions, and should use a mounting accessory recommended by the manufacturer.

15. Outdoor Antenna Grounding – If an outside antenna or cable system is connected to the product, be sure the antenna or cable system is grounded so as to provide some protection against voltage surges and built-up static charges. Article 810 of the National Electrical Code, ANSI/NFPA 70, provides information with regard to proper grounding of the mast and supporting structure, grounding of the lead-in wire to an antenna discharge unit, size of grounding conductors, location of antenna-discharge unit, connection to grounding electrodes, and requirements for the grounding electrode. See Figure 1.

9. A product and cart combination should be moved with care. Quick stops, excessive force, and uneven surfaces may cause the product and cart combination to overturn.
16. Lightning – For added protection for this product during a lightning storm, or when it is left unattended and unused for long periods of time, unplug it from the wall outlet and disconnect the antenna or cable system. This will prevent damage to the product due to lightning and power-line surges.
17. Power Lines – An outside antenna system should not be located in the vicinity of overhead power lines or other electric light or power circuits, or where it can fall into such power lines or circuits. When installing an outside antenna system, extreme care should be taken to keep from touching such power lines or circuits as contact with them might be fatal.

10. Ventilation – Slots and openings in the cabinet are provided for ventilation and to ensure reliable operation of the product and to protect it from overheating, and these openings must not be blocked or covered. The openings should never be blocked by placing the product on a bed, sofa, rug, or other similar surface. This product should not be placed in a built-in installation such as a bookcase or rack unless proper ventilation is provided or the manufacturer’s instructions have been adhered to.

18. Overloading – Do not overload wall outlets, extension cords, or integral convenience receptacles as this can result in a risk of fire or electric shock.
11. Power Sources – This product should be operated only from the type of power source indicated on the marking label. If you are not sure of the type of power supply to your home, consult your product dealer or local power company. For products intended to operate from battery power, or other sources, refer to the operating instructions.
19. Object and Liquid Entry – Never push objects of any kind into this product through openings as they may touch dangerous voltage points or short-out parts that could result in a fire or electric shock. Never spill liquid of any kind on the product.
Page 4 of the Marantz PMD505 user manual — NEC - NATIONAL ELECTRICAL CODE
Page 4 · click to enlarge
Page 4
20. Servicing – Do not attempt to service this product yourself as opening or removing covers may expose you to dangerous voltage or other hazards. Refer all servicing to qualified service personnel.
22. Replacement Parts – When replacement parts are required, be sure the service technician has used replacement parts specified by the manufacturer or have the same characteristics as the original part. Unauthorized substitutions may result in fire, electric shock, or other hazards.
21. Damage Requiring Service – Unplug this product from the wall outlet and refer servicing to qualified service personnel under the following conditions:
23. Safety Check – Upon completion of any service or repairs to this product, ask the service technician to perform safety checks to determine that the product is in proper operating condition.

a. When the power-supply cord or plug is damaged.

24. Wall or Ceiling Mounting – The product should be mounted to a wall or ceiling only as recommended by the manufacturer.

b. If liquid has been spilled, or objects have fallen into the product.

c. If the product has been exposed to rain or water.

25. Heat – The product should be situated away from heat sources such as radiators, heat registers, stoves, or other products (including amplifiers) that produce heat.

d. If the product does not operate normally by following the operating instructions. Adjust only those controls that are covered by the operating instructions as an improper adjustment of other controls may result in damage and will often require extensive work by a qualified technician to restore the product to its normal operation.

e. If the product has been dropped or damaged in any way, and

f. When the product exhibits a distinct change in performance – this indicates a need for service.

FIGURE 1 EXAMPLE OF ANTENNA GROUNDING AS PER NATIONAL ELECTRICAL CODE, ANSI/NFPA 70

ANTENNA LEAD IN WIRE

GROUND CLAMP

ANTENNA DISCHARGE UNIT (NEC SECTION 810-20)

ELECTRIC SERVICE EQUIPMENT

GROUNDING CONDUCTORS (NEC SECTION 810-21)

GROUND CLAMPS

POWER SERVICE GROUNDING ELECTRODE SYSTEM (NEC ART 250, PART H)

NEC - NATIONAL ELECTRICAL CODE

This Class B digital apparatus complies with Canadian ICES-003. Cet appareil numérique de la Classe B est conforme à la norme NMB-003 du Canada.

Page 6 of the Marantz PMD505 user manual — PMD505
Page 6 · click to enlarge
Page 6

Thank you very much for purchasing the MARANTZ component stereo cassette tape deck. MARANTZ proudly presents this advanced tape deck to audiophiles and music lovers as a further proof of MARANTZ’s non-compromising pursuit of the ultimate in sound quality. The high quality performance and easy operation are certain to provide you with many hours of outstanding listening pleasure.

Please check to make sure the following items are included with the main unit in the carton:

(Warranty card is on the last page of this instructions.) 1 (2) Stereo audio cable 2 (3) Remote control unit (RC455SD) 1 (4) AA (R6) Batteries 2 (5) Market survey card 1

– TABLE OF CONTENTS –

FEATURES

FEATURES 1 CONNECTION 1 NAMES AND FUNCTIONS OF PARTS 2, 3 CASSETTE TAPES 3 AUTOMATIC TAPE SELECTION 3 PLAYBACK 4

Computer Controlled Mechanism Dolby HX-Pro Headroom Extension System Dolby B & C Noise Reduction Systems Dual Computing Tape Counter with 4-Digit Readout FL Peak Level Meters Auto Tape Selector 2-Speed Dubbing Relay Playback Remote Controllable Pitch Control Function (DECK A)

RELAY PLAY 4 RECORDING 5

PROPER RECORDING LEVEL 5 REC MUTE AND REC PAUSE BUTTON 5 DUBBING 6

SYNCHRO REVERSE DUBBING 6, 7 SYNCHRO RECORDING PROCEDURE 7 TAPE COUNTER 7 DOLBY B AND C NOISE REDUCTION SYSTEM 7 DOLBY HX PRO HEADROOM EXTENSION SYSTEM 7 MAINTENANCE 8 REMOTE CONTROL 9

USING THE REMOTE CONTROL UNIT 9 TROUBLESHOOTING 10 SPECIFCATIONS 10

CONNECTION

Leave your entire system (including this cassette deck) turned off until all connections between the deck and other components have been completed.

PMD505

Marantz PMD505 — PMD505 diagram (page 6)
Fig. 1

Connecting the Deck to an Amplifier

Before connecting the deck to your amplifier, please review your amplifier’s instruction manual. Use the white plugs for the left channel and red plugs for the right channel. Tape Dubbing

If the deck is placed near an amplifier, TV or tuner, noise (induced hum) or beat interference may result, especially during FM or AM reception. If this occurs, place the deck further away from other components or reorient its position.

Many stereo amplifiers and receivers have tape dubbing circuitry so that tape duplication can be performed between two or more tape decks. Review your amplifier’s instruction manual for a full explanation of this mode of operation. Connecting Headphones

Marantz PMD505 — PMD505 diagram (page 6)
Fig. 2

A mechanical sound is heard the first time the power switch is set to “ON” after the power cord is plugged into an outlet. This is the sound of the cassette mechanism being set to the proper operating state, and is normal. (When using an AC outlet on a receiver or amplifier, used an “UNSWITCHED” outlet.)

To listen through headphones, plug your headphones into the PHONES jack. REMOTE CONTROL

For the operation of the system control. The following functions of this Marantz product can be remote- controlled.

Play, FF, REW, Stop, Rec, Rec Pause, Rec Mute, Counter Reset, Direction, Deck A, Deck B. However, the remote-controllable functions are dependednt on the type of remote control used. If this Marantz product is to be remote-controlled by a Marantz Learning Remote Control, please refer to the Command Code Table of page 8.

(1) Operating Instructions · Receiver or amplifier · Installation Precautions

Page 7 of the Marantz PMD505 user manual — q t w i u w !0 !4
Page 7 · click to enlarge
Page 7

NAMES AND FUNCTIONS OF PARTS

r !5 o !2e y eu !3 !1 o

Marantz PMD505 — NAMES AND FUNCTIONS OF PARTS diagram (page 7)
Fig. 3

HIGH PAUSE NORMAL REC MUTE REC REC LEVEL SYNC REV

q t w i u w !0 !4

q Power Switch (POWER) Press once to turn the power to deck on, and once more to turn the power off. The deck remains in a standby (non-operative) mode for approximately 2 seconds after it is switched on.

r Dolby NR Switch (DOLBY NR) To record or playback tapes with Dolby B or C-type noise reduction, set this switch to “B” or “C” . Turn it “OFF” when not using the Dolby NR system.

t Reverse Mode Switch (REV MODE) Select the tape of tape transport. The reverse mode can be set to (one side), (both side), (continuous playback).

w Eject Button ( EJECT) Press this button to open the cassette compornent cover, When the tape is running, press the STOP ( ) button first to stop tape transport, then press the Eject button.

y Dubbing Speed Buttons (DUBBING SPEED) Pressing the NORMAL button starts regular speed dubbing from deck A to deck B. Press the HIGH button to perform dubbing at double speed. See page 6. u Tape Transport Buttons

e Counter Reset Button (COUNTER RESET) Press this button to reset the tape counter to zero.

(PLAY)Forward Play ButtonPress to Forward playback tape. (PLAY)Reverse Play ButtonPress to Reverse playback tape. (STOP)Stop ButtonPress to stop the tape in any mode. (REW)Fast Rewind ButtonPress for fast rewind. (FF)Fast Forward ButtonPress for fast forwarding (REC) (Deck B only)Rec ButtonPress the REC button and PLAY button simultaneously to start recording. If only the REC button is pressed, the deck enters the Recording Pause mode. REC MUTE (Deck B only)Rec Mute ButtonPressing this button in the Recording Pause mode will start Auto Rec Mute, and a 4-second silent space is recorded onto the tape. See page 5. (PAUSE) (Deck B only)Rec Pause ButtonPress this button to enter the recording pause mode from the recording or recording mute mode. This button can only be used during recording. See page 5.
Marantz PMD505 — q t w i u w !0 !4 diagram (page 7)
Fig. 4 · q t w i u w !0 !4

i Rec Level Control (REC LEVEL) This knob adjusts the recording input level. It affects the level in both channels. See page 5.

!1 Remote Sensor Each of “PLAY, FF, REW, STOP, REC, REC PAUSE, REC MUTE, DIRECTION, COUNTER RESET, DECK A and DECK B” functions can be remote controlled with wireless handset.

o Cassette Compartment Cover If the cover is not closed completely, the tape transport buttons will remain inoperative.

!0 Headphone Jack (PHONES) For private music enjoyment without disturbing others, or for monitoring a recording, a headphone set may be connected to this jack. Use a headphone with an impedance rating of 8 to 1200 ohms.

!2 Syncro Reverse Button (SYNC REV) Press this button to set the SYNC REV mode. See page 6.

Page 8 of the Marantz PMD505 user manual — CASSETTE TAPES
Page 8 · click to enlarge
Page 8

!3 Display Indicators with an encircled number light up when the corresponding button is pressed.

a Peak Level Meter

Marantz PMD505 — a Peak Level Meter diagram (page 8)
Fig. 5 · a Peak Level Meter

dB – 30 20 10 8 3 0 3 +6 R

b Direction & Pause Indicators

c Multi Counter

d SYNC REV Indicator

e Mode Indicators

f Dubbing Indicators

a b b d c e f c e

!4 PITCH CONTROL Knob Used to vary the pitch (key of music) during playback of a cassette. (Only the pitch of Deck A can be varied.) Turn the PITCH CONTROL clockwise to heighten the pitch by increasing the tape transport speed. Turn it counterclockwise to lower the pitch by decreasing the tape transport speed.

!5 TIMER Switch (TIMER playback/TIMER recording) The select switch for use in timer playback or timer recording using an audio timer. Set this switch to the OFF position when timer playback or timer recording is not required.

CASSETTE TAPES

Handling Precautions C-120 Cassettes C-120 cassette tapes are not recommended as they use a very thin tape base which may become tangled around the capstan or pinch roller. Tape Slack Before putting a tape into the deck, take up any slack with a pencil or your finger tip. This precaution prevents the tape from becoming entangled around the capstan or pinch roller.

Storage Precautions Do not store cassette tapes in a place where they will be subject to: Extremely high temperature or excessive moisture Excessive dust Direct sunlight Magnetic fields (near TV sets or speakers) To eliminate tape slack, store your cassettes in cassette cases with hub stops

Marantz PMD505 — CASSETTE TAPES diagram (page 8)
Fig. 6

Accidental Erasure Prevention All cassettes have erasure prevention tabs for each side. To protect valuable recordings from accidental or inadvertent erasure, remove the tab for the appropriate side with a screwdriver or another tool. To record on a tape whose erasure prevention tabs have been removed, cover the tab holes with adhesive tape.

Erasure prevention tab for side A

Erasure prevention tab for side B

Marantz PMD505 — CASSETTE TAPES diagram (page 8)
Fig. 7

This Stereo Cassette Deck contains an automatic tape selector which automatically selects the optimum bias and equalization for the tape in use. This is accomplished by detection of the tape type detections holes in the cassette housing.

If a tape without tape type detection holes is used, the deck will be set for normal tapes.

Page 9 of the Marantz PMD505 user manual — q e
Page 9 · click to enlarge
Page 9

PLAYBACK

The operations described below apply to deck A and deck B alike. Switch on your amplifier or receiver. Set the Function Selector or Tape Monitor switch on your amplifier or receiver to TAPE or Tape monitor position. The numbers in the illustration below depict the order in which operation steps are carried out.

r e

Marantz PMD505 — r e diagram (page 9)
Fig. 8 · r e

HIGH PAUSE NORMAL REC MUTE REC REC LEVEL SYNC REV

q w u y t

6. Press the PLAY ( or ) button y to being playback.
2. Press the EJECT button w to open the cassette compartment cover e. Transport Direction Indicator Forward 3. Load the cassette tape and close the cassette compartment cover e. Reverse 4. When listening to a tape that has been recorded with Dolby noise reduction, set the DOLBY NR switch r to match the system used 7. Press the STOP ( ) button u to stop the playback. at the time of recording. In the continuous playback mode (REV MODE set to ), playback of both tape sides will be repeated 5 times and then DOLBY NR stop automatically. C If different types of Dolby noise reduction are used for record B OFF and playback, playback response will be adversely effected. 5. Select the type of tape transport with the REV MODE switch t. When power is turned off during tape transport, it may not be possible to remove the cassette by pressing the EJECT REV. MODE button. In this case, turn on power again before you press the EJECT button. Mode Switch position To listen to one side only To listen to playback of both sides To listen to continuous play back of both sides and both decks. ModeSwitch position To listen to one side only To listen to playback of both sides To listen to continuous play back of both sides and both decks.

RELAY PLAY (continuous playback of the tapes in deck A and deck B)

Load a cassette tape into deck A and B, and set the Dolby NR button correctoly.

w

Marantz PMD505 — w diagram (page 9)
Fig. 9 · w

HIGH PAUSE NORMAL REC MUTE REC REC LEVEL SYNC REV

q e

1. REV MODE set to q . 2. Press the PLAY ( ) button w of the deck you first wish to listen to. 3. To stop relay play, press the STOP ( ) button e of the deck currently playing the tape.

Relay play will play deck A and B in succession for 5 times, upon which playback stops (Deck A Deck B Deck A Deck B Deck A) or (Deck B Deck A Deck B Deck A Deck B).

Page 10 of the Marantz PMD505 user manual — REC MUTE AND REC PAUSE BUTTON
Page 10 · click to enlarge
Page 10

RECORDING (DECK B only)

Switch on your amplifier or receiver and the source component. Set the Function Selector and the REC Selector on your amplifier or receiver to the source to record, with Tape Monitor switch (it available) set to monitor

!0 e ot

Marantz PMD505 — !0 e ot diagram (page 10)
Fig. 10 · !0 e ot

HIGH PAUSE NORMAL REC MUTE REC REC LEVEL SYNC REV

q w u y i u r

1. Press the POWER switch q to the ON ( ) position. 2. Load the cassette tape w . (Check that the erasure prevention tabs of the cassette housing have not been broken off.) 3. Move the DOLBY NR switch e and select the Dolby NR type that suits the recording.

5. Press the REC ( ) button !0 to set the recording pause mode. The and indicator will light up. 6. Adjust the recording level with the REC LEVEL control y while watching the Peak Level Meter. 7. Press the PLAY ( ) button u to start the recording. The and the Indicator will light during recording. 8. To pause the recording, press the PAUSE ( ) button o. Press the PLAY ( ) button u or PAUSE ( ) button o to resume recording. 9. To stop recording, press the STOP ( ) button i.

REC PLAY

DOLBY NR

OFF

Caution: Be careful not to erase important recordings by mistake. Inadvertent start of recording will happen in the following cases: 1. If the PLAY button is pressed while the indicator lights, recording starts. 2. If the PLAY and REC ( ) button are pressed at the same time, recording starts. The best way to avoid accidental erasure is to break off the two erasure prevention tabs on the cassette housing.

4. Select the type of tape transport with the REV MODE switch r .
ModeSwitch position To record on only one side To continuously record on both sidesor

PROPER RECORDING LEVEL

A too high recording level can saturate the tape and cause distortion. On the other hand, if the recording level is set too low, soft passages will be marked by residual noise. A proper recording level is the single most important factor for making well balanced recordings.

Guideline for maximum recording level

TYPE q (Normal)0 dB level on peaks TYPE w (High position)1 dB level on peaks TYPE r (Metal)3 dB level on peaks

REC MUTE AND REC PAUSE BUTTON

1. To record a 4-second blank section during recording: Press the REC MUTE button t . A 4-second blank will be recorded and the deck will enter the recording Pause mode. 2. To record a 4-second blank section during the recording Pause mode: Press the REC MUTE button t from the recording Pause mode. A 4 second blank will be recorded and the deck will enter the recording Pause mode again.
3. To cancel recording of blank space: Press the PAUSE ( ) button o . Blank space recording will be canceled and the deck enters the recording Pause mode. 4. To extend the blank section with another 4 seconds or more: Simply press the REC MUTE button t and the blank section will be increased with another 4 seconds.
Page 11 of the Marantz PMD505 user manual — e r
Page 11 · click to enlarge
Page 11

DUBBING (from deck A to deck B)

Switch on the amplifier or receiver. Set the Function Selector or Tape Monitor switch on your amplifier or receiver to TAPE or Tape monitor position.

w

w t

Marantz PMD505 — w diagram (page 11)
Fig. 11 · w

HIGH PAUSE NORMAL REC MUTE REC REC LEVEL SYNC REV

e

q u y r

1. Press the POWER switch q to the ON ( ) position. 2. Load the cassette tape to be played on deck A and the one to be recorded in deck B w . 3. Select the type of tape transport with the REV MODE switch e .

4. To being normal speed dubbing, press the DUBBING SPEED NORMAL button r. The NORM DUB indicator will light at this time. To high speed dubbing, press the DUBBING SPEED HIGH button r. The HIGH DUB indicator will light at this time. 5. To stop dubbing, press the STOP ( ) button t of deck A or deck B. When dubbing, the recording level and the Dolby NR recording will be the same as those of the playback tape, regardless of the positions of the REC LEVEL control and the DOLBY NR switch. When listening to the playback sound during normal speed dubbing, the DOLBY NR switch remains off even if it is pressed. Operation using the REC MUTE u and PAUSE ( ) y buttons of deck B is permitted during normal speed dubbing.

REV. MODE

Marantz PMD505 — REV. MODE diagram (page 11)
Fig. 12
Reverse modeOperation Dubbing is performed only for one side. The decks stop when either deck A or B reaches the end of the tape. orThe tape direction is reversed on each deck when they reach the end of the tape. (This is convenient for dubbing to a tape with a different length.)

SYNCHRO REVERSE DUBBING

w

w t

Marantz PMD505 — SYNCHRO REVERSE DUBBING diagram (page 11)
Fig. 13

HIGH PAUSE NORMAL REC MUTE REC REC LEVEL SYNC REV

e r

q u y i

During dubbing of the side facing you, the deck that first reaches the end if the tape will stand by until the other deck reaches the end of the tape, direction together. (Depending on the manufacturer, the length of tapes having the same recording time may differ somewhat. Setting this mode permits the arrangement of the begining portion of the opposite side of the tape.)

1. Press the POWER switch q to the ON ( ) position. 2. Load the cassette tape to be played on deck A and the one to be recorded in deck B w . 3. Select the position of the REV MODE switch e .
Page 12 of the Marantz PMD505 user manual — DOLBY HX PRO HEADROOM EXTENSION SYSTEM
Page 12 · click to enlarge
Page 12

4. Press the SYNC REV button i to set the SYNC REV Mode. The SYNC REV Indicator will light up. To release SYNC REV mode, press the SYNC REV button again. When direction of Deck A and Deck B is only Forward ( ), the SYNC REV mode can be set. 5. To being normal speed dubbing, press the DUBBING SPEED NORMAL button r. The NORM DUB indicator will light at this time. To high speed dubbing, press the DUBBING SPEED HIGH button r. The HIGH DUB indicator will light at this time.

6. To stop dubbing, press the STOP ( ) button t of deck A or deck B. When dubbing, the recording level and the Dolby NR recording will be the same as those of the playback tape, regardless of the positions of the REC LEVEL control and the DOLBY NR switch. When listening to the playback sound during normal speed dubbing, the DOLBY NR switch remains off even if it is pressed. Operation using the REC MUTE u and PAUSE ( ) y buttons of deck B is permitted during normal speed dubbing.

SYNCHRO RECORDING PROCEDURE (Deck B)

The following operation is available only when a MARANTZ CD player with the synchro recording capability is connected to the cassette deck. To use synchro recording, connect the remote control cord terminals on the CD player and cassette deck.

4. Adjust the recording level with the REC LEVEL control. 5. Start edit playback of the CD player. (The operation procedure may be variable between CD players with edit function. Refer to the instruction manual of your CD player.)

When the MARANTZ PMD371 CD changer is used, it is possible to set the REV. MODE switch to “ ”. (This enables to record both A and B sides continuously.) When other MARANTZ CD player than the above mentioned models is used, set the REV. MODE switch to “ ”. (This causes only tape side A or B to be recorded.)

1. Load a cassette tape in Deck B. 2. If Dolby NR recording is required, select type B or C. 3. Press the RECORD/o button to put the cassette deck in recordpause mode.

TAPE COUNTER

1. Operation of the Tape Counter (1) Press the COUNTER RESET button to reset the counter to

During recording and playback operations, the counter is useful for noting the location of existing programs or positions where recording is to be started. The reading of this counter does not correspond with that of any other deck.

“ ”. (2) By using the PLAY, FF, or REW functions, the reading of the

counter will change to indicate index position.

DOLBY B AND C NOISE REDUCTION SYSTEM

The Dolby noise reduction system substantially reduces the tape background noise (hiss) inherent in the cassette medium. Tape background noise consists primarily of high frequency information, which is particularly annoying during soft passages, The Dolby NR system increases the level of low volume mid and high frequency signals during recording and reduces the level of these signals by an identical amount during playback, As a result, the playback signal is identical to the original source, but the level of background noise generated by the tape is greatly reduced.

The operating principle of Dolby C NR is similar to that of Dolby B NR except for the encoding/decoding response curves. The noise reduction effect obtained with Dolby C NR is up to 20 dB, compared to 10 dB with Dolby B NR. In addition, Dolby C NR uses an anti-saturation network and spectral skewing circuitry for a significant improvement in the dynamic range of the mid-to high- frequencies.

DOLBY HX PRO HEADROOM EXTENSION SYSTEM

This deck is equipped with the Dolby HX PRO headroom extension system. Since the system functions automatically during recording, no switching operation or adjustment is required. The system is effective with any type of Normal, High and Metal tape. The Dolby HX PRO headroom extension system functions during recording to raise the saturation level in the high frequency range. Therefore, most of the high frequency range distorted or lost during recording on conventional cassette decks are more faithfully recorded on the new MARANTZ cassette deck.

Features of the Dolby HX PRO Headroom Extension System (1) Performance of Normal and High Position tapes can be improved

to very close of that offered by Metal tape. (2) The dynamics in the high frequency range are improved

significantly. (3) Since no decoding is necessary during playback, the improved

sound can be enjoyed on any type of tape deck, including portable players and car audio systems. (4) The system functions whether the Dolby B/C NR system is

engaged or not.

Page 13 of the Marantz PMD505 user manual — DECK A DECK B DIRECTION ( )
Page 13 · click to enlarge
Page 13

MAINTENANCE

Cleaning the Pinch Rollers and Capstans

After long usage, tape coating or dust may adhere to the heads, causing deterioration of sound. Therefore, the parts depicted in the illustration should be cleaned reguraly. Use a cotton swab moistened with a tape head cleaning solution (such as alcohol).

If the pinch roller or capstans accumulate dust, tape transport may become unstable, as a result from slippage, during recording or playback. The tape can also be damaged if it gets entangled in the capstan. Clean these parts with a cotton swab or a soft cloth moistened with a tape head cleaning solution (such as alcohol).

Demagnetizing the Heads

The heads may become magnetized after long usage or if storongly magnetized objects are brought near them. The result is a generation of noise, loss of the high frequency range, and in extreme cases erasure of trable components on pre-recorded tapes in combination with added noise. Thus, the heads should be demagnetized at regular intervals. (Head demagnetizers are sparately available from your dealer.)

How to Demagnetize the Tape Heads

1. Turn off the power. 2. Turn on the demagnetizer while it is at least 30 cm away from the heads. Bring the demagnetizer near the heads and slowly move it in small circles four or five times in front of each head, making sure you do not touch them. 3. Slowly move the demagnetizer away and turn it off when it is at least 30 cm away from the heads. 4. For more details, please read the User Guide provided with the demagnetizer (optional).

CAPABILITY OF REMOTE CONTROL

RC-5 CODE

PLAY ( ) FF ( ) REW ( ) PAUSE ( ) STOP ( ) REC REC MUTE COUNTER RESET

1853 1852 1850 1848 1854 1855 1842 1849 1844 1846 1847

DECK A DECK B DIRECTION ( )

Head cleaning

Page 14 of the Marantz PMD505 user manual — ⁄0 (STOP) button:
Page 14 · click to enlarge
Page 14

REMOTE CONTROL

USING THE REMOTE CONTROL UNIT

1. Remote control Operate the remote control unit (RC455SD) within a distance of approx. 5 m from the infrared signal reception window (remote sensor) on the front of the CASSETTE DECK. Remote control operation may not be possible if the remote control unit's transmitter is not pointing in the direction of the remote sensor or if there is an obstruction between the transmitter and the remote sensor.
Marantz PMD505 — USING THE REMOTE CONTROL UNIT diagram (page 14)
Fig. 14
Marantz PMD505 — USING THE REMOTE CONTROL UNIT diagram (page 14)
Fig. 15

z A/B button Mechanism select buttons (DECK A/B): Press to select the deck mechanism, Deck A or Deck B, to be controlled.

2. Loading batteries Batteries in this remote control unit have a life of approximately 1 year under normal operating conditions. When the remote control unit is not to be used for an extended period of time, remove the batteries. Also, when you notice that the batteries are starting to run down, replace them as soon as possible.

x (REC PAUSE) button:

Press this button to enter the recording pause mode from the recording or recording mute mode. This button can only be used during recording. See page 5.

(1) Remove the battery cover.

c REC button:

Marantz PMD505 — c REC button: diagram (page 14)
Fig. 16 · c REC button:

Press the REC button, the deck enters the Recording Pause mode. See page 5.

v (Play button): Press to playback tape.

b (Fast rewind button): Press for fast rewind.

(2) Insert the batteries with correct / orientation.

n RESET button: Press to tape counter reset.

Marantz PMD505 — c REC button: diagram (page 14)
Fig. 17 · c REC button:

m REC MUTE button: Press the REC MUTE button, the Recording Pause mode will start Auto Rec Mute, and a 4-second silent space is recorded onto the tape. See page 5.

, (DIRECTION) button: After starting playback, press the forward ( ) or reverse ( ) to select the top playback direction.

. (Fast forward button): Press for fast forwarding.

(3) Close the battery cover until it clicks shut.

Marantz PMD505 — c REC button: diagram (page 14)
Fig. 18 · c REC button:

⁄0 (STOP) button:

Press to cancel any operation modes and stop the tape travel of the deck.

Remote control unit

Page 15 of the Marantz PMD505 user manual — SPECIFICATIONS
Page 15 · click to enlarge
Page 15

TROUBLESHOOTING

Check the following before you draw the conclusion that your Stereo Cassette Deck is malfunctions. 1. Are all the connections correct? 2. Are all system components being operated correctly in accordance with the operating instructions? 3. Are the speakers and amplifier/receiver functioning correctly? If the tape deck still does not function properly, check the symptom against the list below. If the symptom does not correspond to the check list, please contact your MARANTZ dealer.

Power cord is disconnected. Tape is loose. Cassette is not loaded properly. Defective cassette.

Check power cord. Tighten tape with a pencil, etc. Load cassette properly. Replace cassette.

Tape does not run.

Tape is not recorded when REC button is pressed.

No cassette is loaded. Erase prevention tabs are broken off.

Load cassette. Cover hole with plastic tape.

Heads, capstan or pinch roller are dirty. Tape is wound too tight. Recording input level is too high. Tape is worn out and has “dropouts”.

Clean them. Fast forward or rewind to loosen tape winding. Adjust recording input level. Replace tape.

Sound is warbled or distorted.

Tape is worn. Heads, capstan or pinch roller are dirty. Heads are magnetized. Recording input level is too low.

Replace tape. Clean them. Demagnetize heads. Adjust recording input level.

Excessive noise.

High frequency range (treble) is emphasized.

Dolby NR switch is set improperly.

Set Dolby NR switch properly.

Heads are dirty. Tape is worn.

Clean them. Replace tape.

High frequency range (treble) is lost.

If the POWER switch is turned off in either during recording or playback and the unit is stopped, there may be case when the cassette cannot be removed, even if the ( EJECT) button is pressed.

Turn the POWER switch ON ( ) again, and then press the STOP ( ) button. Now, press the ( EJECT) button to remove the cassette tape.

The cassette tape cannot be removed.

SPECIFICATIONS

Type Vertical tape loading; 4-track 2-channel stereo double cassette deck Heads Playback head 1 recording/playback head 1 Erase head (Double-gap ferrite) 1 Motors DC servo motor 2 Tape Speed 4.8 cm/sec. 9.5 cm/sec. (When high speed dubbing) Fast Forward,

Inputs LINE 100 mV input level at maximum Input impedance: 50 kohms unbalanced Output LINE 460 mV (0 dB) output level at maximum (with 47 kohms load, recorded level of 200 nWb/mm) PHONES 0.95 mW output level at maximum (optimum load impedance 8 ohms ~ 1.2 kohms) Power Consumption 0.13 A Dimensions 17-7/16 (W) 5-5/16 (H) 12-9/16 (D) inches 440 (W) 124 (H) 286 (D) mm Weight 8.58 lbs oz (4.0 kg)

Rewind Time Approx. 110 sec. with a C-60 cassette Recording Bias Approx. 100 kHz Overall S/N Ratio

(at 3% THD level) Dolby C NR on: more than 74 dB (CCIR/ARM) Overall Frequency

Response 25 ~ 18,000 Hz 3 dB (at 20 dB, Metal tape) Channel Separation More than 40 dB (at 1 kHz) Wow & Flutter 0.09 % WRMS, 0.1 % w. peak

* Above specifications ans design are subject to change without prior notes.

Dolby noise reduction and HX Pro headroom extension manufactured under license from Dolby Laboratories Licensing Corporation. HX Pro originated by Bang & Olufsen.

“DOLBY”, the double-D symbol and “HX PRO” are trademarks of Dolby Laboratories Licensing Corporation.

Problem · Cause Remedy

Page 16 of the Marantz PMD505 user manual — How You Can Get Service
Page 16 · click to enlarge
Page 16

Limited Warranty

Limitation of Implied Warranties

Your Marantz Professional product is warranted against manufacturer defect for period of one year parts and labor.

All implied warranties, including warranties or merchantability and fitness for a particular purpose, are limited in duration to the length or this warranty.

Except as specified below this warranty covers defects in material and workmanship. The following are not covered under warranty.

Exclusion of Damages

1. a) Damage, deterioration, malfunction or failure to meet performance specification resulting from: b) Accidents, acts of nature, misuse, abuse, neglect or

Liability for any defective product is limited to repair or replacement of the product at manufacturer's option. Manufacturer shall not be liable for damage to other products caused by any defects in Marantz products, damages based upon inconvenience or loss of use of the product, or any other damages, whether incidental, consequential, or otherwise.

unauthorized product modification. c) Improper installation, removal or maintenance, or failure

to follow supplied instruction. d) Repair or attempted repair by a non Marantz authorized

agent. e) Any shipment of the product (claims must be presented

Some states do not allow limitations on how long an implied warranty lasts and/or do not allow the exclusion or limitation of incidental or consequential damages, so the above limitations and exclusions may not apply to you.

to the carrier). f) Any cause other than a defect in manufacturing.

2. Cleaning, check-ups with no fault found, or changes incurred for installation, removal or reinstallation of the product.

How State Law Relates to the Warranty

This warranty gives you specific legal rights, and you may have other rights which may vary from state to state.

3. Any serialized product on which the serial number has been defaced, modified or removed.
4. Batteries and battery chargers.
5. Accessories, including but not limited to, cables, mounting hardware and brackets, cleaning accessories, power cords and adapters, and carry cases.

Marantz Professional Service Number:

Marantz Professional Factory Service (630) 820-4800

6. Product purchased outside the United States, its possessions or territories.

This warranty is enforceable only in the United States and its possessions or territories.

Non-Transferable Warranty

This warranty may be enforced only by the original purchaser.

What We Will Pay For

We will pay for all labor and material expense for items covered by the warranty.

How You Can Get Service

1. If your unit needs service, contact our service referral at the appropriate telephone number indicated below. We will advise you of the name and location of one or more warranty authorized service centers from which service may be obtained. Please do not return your unit directly to us. 2. You must pay any shipping charges if it is necessary to ship the product for service. If the necessary repairs are covered by the warranty, we will pay the return shipping charges to your location anywhere in the United States or its territories. 3. Whenever warranty service is required, you must present the original dated sales receipt or other proof of date purchased.

Page 17 of the Marantz PMD505 user manual — R
Page 17 · click to enlarge
Page 17

R

is a registered trademark.

Printed in China 02/07 SG 286W851280

Fix-it

Troubleshooting

Common problems, likely causes, and what to do.

ProblemPossible causeRemedy
Tape does not run. Power cord is disconnected. Tape is loose. Cassette is not loaded properly. Defective cassette. Check power cord. Tighten tape with a pencil, etc. Load cassette properly. Replace cassette. p.15
Tape is not recorded when REC button is pressed. No cassette is loaded. Erase prevention tabs are broken off. Load cassette. Cover hole with plastic tape. p.15
Sound is warbled or distorted. Heads, capstan or pinch roller are dirty. Tape is wound too tight. Recording input level is too high. Tape is worn out and has “dropouts”. Clean them. Fast forward or rewind to loosen tape winding. Adjust recording input level. Replace tape. p.15
Excessive noise. Tape is worn. Heads, capstan or pinch roller are dirty. Heads are magnetized. Recording input level is too low. Replace tape. Clean them. Demagnetize heads. Adjust recording input level. p.15
High frequency range (treble) is emphasized. Dolby NR switch is set improperly. Set Dolby NR switch properly. p.15
High frequency range (treble) is lost. Heads are dirty. Tape is worn. Clean them. Replace tape. p.15
The cassette tape cannot be removed. If the POWER switch is turned off in either during recording or playback and the unit is stopped, there may be case when the cassette cannot be removed, even if the ( EJECT) button is pressed. Turn the POWER switch ON ( ) again, and then press the STOP ( ) button. Now, press the ( EJECT) button to remove the cassette tape. p.15

Ask about the Marantz PMD505

Owners and our team usually reply within a day — and your question helps the next person too.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
No questions yet about the Marantz PMD505

Be the first to ask — other owners or our team will answer.

Original document

Marantz PMD505 manual PDF

17 pages·492 KB·Stereo System·PDF
Click any page above to open it here
Page 1 / …
100%
Loading pages…