Instruction/ maintenance manual of the product GCB-24H APW Wyott
Go to page of 20
ANSI/NSF4 R APW WYOTT Foodservice Equipment Comp any P .O. Box 1829 Cheyenne, WY 82003 +1 (307) 634-5801 Phone +1 (800) 752-0863 T oll Free +1 (307) 637-8071 Fax www .apwwyott.com INST ALLA TION AND OPERA TING INSTRUCTIONS IMPORT ANT FOR FUTURE REFERENCE Please complete this information and retain this manual for the life of the equipment.
CAUTION: These models are designed, built, and sold for commercial use. If these models are positioned so the general public can use the equipment, make sure that cautions, warnings, and operating instructions are clearly posted near each unit so that anyone using the equipment will use it correctly and not injure themselves or harm the equipment.
IMMEDIA TEL Y INSPECT FOR SHIPPING DAMAGE All containers should be examined for damage before and during unloading. The freight carrier has assumed responsibility for its safe transit and delivery . If equipment is received damaged, either apparent or concealed, a claim must be made with the delivering carrier .
GENERAL INST ALLA TION INSTRUCTIONS Ensure gas supply and gas type, as shown on unit nameplate agree. Unit installation must conform with the National Fuel Gas Code, ANSI Z223.1/NFP A 54, the National Gas Installation Code, CSA-B149.1, or the Prop ane Installation Code, CSA-B149.
DIMENSIONS GCB-18H & GCRB-18H : DIMENSIONS GCB-24H & GCRB-24H : 15.61 15.00 18.00 4.00 18.57 25.14 4.95 9.00 30.39 30.08 4.95 8.64 18.57 25.14 3.
4.95 9.55 25.05 33.00 36.00 15.54 18.57 25.14 4.95 10.61 45.00 48.00 15.60 18.57 25.14 3.69 DIMENSIONS GCB-36H & GCRB-36H : DIMENSIONS GCB-48H & GCRB-48H : 6 (126) (243) (636) (838) (914) (396.
CONVERSION ! ! ! Instructions are for conversion from Natural Gas to Propane (L.P .) on all models GCRB and GCB. The conversion should be done before connecting the unit to the gas supply . 1. Remove the knobs and front panel. 2. Remove the orifice fittings from the valve.
! Relight following steps 4 through 6 under S t anding Pilot Lighting Instructions. LIGHTING MAIN BURNER: CAUTION Main burner air supply: European Community: If adjustment becomes necessary in the fie.
Cooking Grates and systematic approach to the loading of the unit will produce the most consistent product results. Place the radiants in their position as shown in Sketch 1. Make sure that the radiant s are setting properly into the slots on the front and rear support s.
SER VICE REP AIR I NOTE: THIS APPLIANCE MUST ONL Y BE SERVICED BY AN AUTHORIZED AGENT . NOTE: Parts protected by the manufacturer or his agent are not to be adjusted by the inst aller , unless the installer is an authorized service agent.
11 PLACE LA V A ROCKS WITH AIR SP ACES BETWEEN THE ROCKS. DO NOT OVER LOAD ROCK GRA TES. Please Use The Following Amount of Lava Rock Per Model. Notes:.
* = Not Shown Item P/N Description Quan Item P/N Description Quan P ARTS LIST : GCB-18H & GCRB-18H 12.
EXPLODED VIEW : GCB-18H & GCRB-18H 15 1 18 1 12 1 13 1 42 1 11 1 14 1 40 1 4 4 20 2 24 2 29 1 34 1 7 2 28 1 17 1 2 1 33 1 1 1 31 1 32 1 8 1 39 1 22 2 37 1 46 1 9 11 25 4 21 12 30 4 19 2 3 6 5 1 6 .
Item P/N Description Quan Item P/N Description Quan * = NOT SHOWN P ARTS LIST : GCB-24H & GCRB-24H 14.
15 9 2 41 1 7 2 10 1 21 1 52 1 8 4 31 1 6 2 19 1 39 1 40 1 18 2 24 4 44 1 35 4 37 2 50 1 42 1 47 1 49 1 34 1 45 1 4 14 25 12 29 1 28 1 1 1 26 6 2 1 23 2 43 1 3 6 22 1 30 1 32 4 38 1 46 1 17 2 48 1 13 .
Item P/N Description Quan Item P/N Description Quan * = NOT SHOWN P ARTS LIST : GCB-36H & GCRB-36H 16.
45 1 21 2 13 3 16 1 2 3 26 2 22 2 34 1 23 2 8 1 32 1 37 1 25 2 31 1 41 2 28 4 55 1 42 3 49 1 52 1 54 1 12 20 4 12 27 12 33 4 36 1 1 1 3 1 9 7 38 1 10 2 5 1 6 6 20 2 11 1 15 3 53 1 46 1 48 1 30 4 40 4 .
P ARTS LIST : GCB-48H & GCRB-48H Item P/N Description Quan Item P/N Description Quan * = NOT SHOWN 18.
45 1 17 2 13 1 18 4 39 1 38 1 16 1 36 1 37 2 33 1 1 1 31 1 21 8 28 2 7 4 24 4 66 1 27 12 14 2 19 2 54 1 29 6 35 1 23 4 67 1 43 2 8 1 2 7 51 1 46 2 30 2 40 4 15 1 50 52 43 53 44 54 45 46 66 47 67 48 49.
20 APW WYOTT EQUIPMENT LIMITED W ARRANTY.
An important point after buying a device APW Wyott GCB-24H (or even before the purchase) is to read its user manual. We should do this for several simple reasons:
If you have not bought APW Wyott GCB-24H yet, this is a good time to familiarize yourself with the basic data on the product. First of all view first pages of the manual, you can find above. You should find there the most important technical data APW Wyott GCB-24H - thus you can check whether the hardware meets your expectations. When delving into next pages of the user manual, APW Wyott GCB-24H you will learn all the available features of the product, as well as information on its operation. The information that you get APW Wyott GCB-24H will certainly help you make a decision on the purchase.
If you already are a holder of APW Wyott GCB-24H, but have not read the manual yet, you should do it for the reasons described above. You will learn then if you properly used the available features, and whether you have not made any mistakes, which can shorten the lifetime APW Wyott GCB-24H.
However, one of the most important roles played by the user manual is to help in solving problems with APW Wyott GCB-24H. Almost always you will find there Troubleshooting, which are the most frequently occurring failures and malfunctions of the device APW Wyott GCB-24H along with tips on how to solve them. Even if you fail to solve the problem, the manual will show you a further procedure – contact to the customer service center or the nearest service center