24V D.C. COMMANDS
D.C. FUSE
0 50V 70V 100V
STAND
OVERL. 300mA. max
SERIAL NUMBER MANUFACTURING DATE
H.P.
L.P.
REPLACE WITH THE SAME TYPE FUSE AND RATING. DISCONNECT SUPPLY CORD BEFORE CHANGING FUSE
UTILISE UN FUSIBLE DE RECHANGE DE MÊME TYPE. DEBRANCHER AVANT DE REMPLACER LE FUSIBLE
THE FOLLOWING ARE TRADEMARKS/REGISTERED TRADEMARKS OF MACKIE DESIGN INC.: "MACKIE", "MACKIE INDUSTRIAL", & THE "RUNNING MAN" FIGURE
+ · LINE 50/60 Hz-115/230V



The UP4000 Series Power Amplifiers are designed for continuous duty in speech, music, paging, and sound reinforcement applications in churches, schools, offices, and other venues demanding high performance, flexible features, and rugged dependability.
Two discrete inputs with priority are provided. The main program input is actively balanced and terminated to a barrier strip connection on the rear panel. The second input is unbalanced and terminated to a single RCA connector. A contact closure will give priority to the balanced input by muting the unbalanced input. The unbalanced input features a parallel output and 0 dB/20 dB sensitivity switch.
Output modes include 4Ω constant impedance and 25V, 50V, 70V, and 100V constant voltage. The smart output stage is fully protected against permanent damage caused by overloading, shorts, and extreme temperatures. Activation of the overload protection circuit turns on 18 VDC (300mA) power at a barrier connector on the rear panel, which may be used to drive a relay or indicating LED. The UP4000 Series will operate on either 115 VAC or 230 VAC, 50/60Hz, as determined by the Voltage Selector switch, and supplied by a detachable IEC power cord. Insulated terminals to connect a backup 24 VDC battery are provided on the rear panel. Switchover to DC is automatic. A programmable stand-by mode allows the amplifier to be turned on remotely with a contact closure.
The front panel provides a Master volume control, and Low and High EQ controls. The control knobs can be removed for security, and their recessed shafts covered with the supplied inserts. LEDs indicate power, stand-by mode, signal present at the output, peak, and output overload. 12 dB/octave Low and High shelving equalization with up to 12 dB of boost or cut at 100Hz and 10kHz can be applied to the output signal.
Accessories include a rack mounting kit.
Part No. 910-142-30 Rev. A 10/01 © 2001 All Rights Reserved. Mackie Industrial. Printed in U.S.A.

REAR PANEL FEATURES
LOW EQ is a shelving filter that provides 12 dB of boost and cut below 100Hz.
POWER INPUT provides a means to connect an external 24 VDC power supply or battery as an alternative or backup power source. The UP4000 Series seamlessly switches to the backup supply if there's an AC power loss. When both AC power and 24 VDC power are connected, the DC power is switched off.
HIGH EQ is a shelving filter that provides 12 dB of boost and cut above 10kHz.
VOLUME is a master volume control used to adjust the overall volume of the signal at the POWER OUTPUTS.
Use the POWER switch to turn the UP4000 Series on and off.
The D.C. FUSE protects the DC power input to the amplifier circuit. Replace with the same type fuse only.
The STD-BY indicator lights when the amplifier is in standby mode. Note: Standby mode is disabled by default. An internal jumper (J1 on the input board) must be changed to enable standby mode. See "Internal Settings" on page 8.
POWER OUTPUTS are screw-terminal connections for connecting speakers to the 4-ohm, 25V, 50V, 70V, or 100V outputs.
The OVERLOAD indicator lights when the amplifier is operating in overload, a condition generally caused by a problem on the speaker line. When the amplifier is switched on, the OVERLOAD light comes on for a few seconds. This is normal and does not indicate a problem.
The SIGNAL indicator lights when a signal is present at the POWER OUTPUTS.
The total impedance of the speakers and cable connected to the "4Ω" constant-impedance output should be 4 ohms. Connect the "4Ω" terminal to the "+" (HIGH) speaker terminal, and the "0" terminal to the "–" (LOW) speaker terminal. Constant-Voltage Output
The PEAK indicator lights when the output signal is approaching clipping.
The ON indicator lights when the UP4000 is turned on and ready for operation.
In a constant-voltage system, each speaker must be equipped with a line transformer having an input voltage equal to that of the line (e.g., 25V, 50V, 70V, or 100V). Typically, these line trans- formers have selectable power taps (i.e., 2.5W, 5W, 10W) for connecting to the constant-voltage line. CAUTION: The sum of the wattage values of the speakers must not exceed the output power of the amplifier.
STD-BY
PEAK OVERLOAD SIGNAL ON
EQ
VOLUME
POWER LOW
HIGH
Constant-Impedance Output · -10 +10 · -10 +10

Connect the appropriate POWER OUTPUT voltage terminal to the "+" (HIGH) leg and the "0" terminal to the "–" (LOW) leg of the distributed speaker system. The ground ( ) terminal is internally connected to the chassis and safety ground on the AC linecord.
The OVERL. 300mA terminal is active whenever the amplifier's overload protection circuit is activated. This provides 18 VDC with a maximum output capacity of 300mA for driving an auxiliary relay or indicating LED.
The OVERL. GND terminal on the COMMANDS terminal strip is the common connection point for OVERL. 300mA.
The PRIORITY terminal activates the priority function for the BALANCED IN by using an external normally-open switch to short-circuit the PRIORITY terminal to the GND (ground) terminal. When the PRIORITY function is enabled, the UNBALANCED IN is muted (no signal from the UNBALANCED IN is transmitted to the outputs).
AC Protection Fuse protects the power supply and amplifier circuitry. Replace only with same type fuse.
Connect the supplied AC linecord to the IEC AC Socket. The AC line fuse is contained in the socket, behind the cover located at the bottom of the socket. Replace only with same type fuse.
This GND terminal is the common connection point for BALANCED IN and PRIORITY.
The BALANCED IN terminals are the main input for the amplifier and accept a balanced line-level signal (0 dBu nominal). This input has a priority function, which mutes the UNBALANCED IN signal when the PRIORITY terminal is shorted to GND.
The VOLTAGE SELECTOR switch is used to select the AC supply voltage for the amplifier. Move the switch so the AC line voltage used appears on the switch (DOWN for 115V, UP for 230V).
The H.P. switch activates a high-pass filter on the balanced and unbalanced inputs, which attenuates frequencies below 300Hz at 12 dB/octave.
The STAND BY terminal is used to turn on the amplifier with a remote switch.
The L.P. switch activates a low-pass filter on the balanced and unbalanced inputs, which attenuates frequencies above 7kHz at 12 dB/octave.
UNBALANCED IN is an RCA jack that can be used instead of the BALANCED IN, or both can be used with the PRIORITY function, which gives the BALANCED IN priority over the UNBALANCED IN.
When the POWER switch is turned on, the amplifier goes into standby mode. In this state, the amplifier is on but signal is not allowed to pass. Shorting the STAND BY terminal to the GND terminal with an external switch causes the amplifier to become fully operational.
PARALLEL OUT is an RCA jack that is in parallel with the UNBALANCED IN jack for connecting to the input of another power amplifier.
The STANDBY GND terminal on the COMMANDS terminal strip is the common connection point for STAND BY.
The SENSITIVITY switch adjusts the input sensitivity of the UNBALANCED IN from 0 dB (typical line-level signals) to 20 dB (for low-level signals).
24V D.C. COMMANDS
D.C. FUSE
0 50V 70V 100V
STAND
BY
OVERL. 300mA. max
FILTER
H.P.
L.P.
REPLACE WITH THE SAME TYPE FUSE AND RATING. DISCONNECT SUPPLY CORD BEFORE CHANGING FUSE
UTILISE UN FUSIBLE DE RECHANGE DE MÊME TYPE. DEBRANCHER AVANT DE REMPLACER LE FUSIBLE
THE FOLLOWING ARE TRADEMARKS/REGISTERED TRADEMARKS OF MACKIE DESIGN INC.: "MACKIE", "MACKIE INDUSTRIAL", & THE "RUNNING MAN" FIGURE
+ · LINE 50/60 Hz-115/230V

Application Diagram
CD Player AM/FM Tuner Cassette or DAT Recorder
24V D.C. COMMANDS
D.C. FUSE
24 VDC Backup Power Supply
STAND
OVERL. 300mA. max
FILTER
DO NOT OPEN
H.P.
L.P.
REPLACE WITH THE SAME TYPE FUSE AND RATING. DISCONNECT SUPPLY CORD BEFORE CHANGING FUSE
UTILISE UN FUSIBLE DE RECHANGE DE MÊME TYPE. DEBRANCHER AVANT DE REMPLACER LE FUSIBLE
THE FOLLOWING ARE TRADEMARKS/REGISTERED TRADEMARKS OF MACKIE DESIGN INC.: "MACKIE", "MACKIE INDUSTRIAL", & THE "RUNNING MAN" FIGURE
POWER INPUT
24V D.C. COMMANDS
D.C. FUSE
24 VDC Backup Power Supply
STAND
BY
OVERL. 300mA. max
SERIAL NUMBER MANUFACTURING DATE
H.P.
L.P.
REPLACE WITH THE SAME TYPE FUSE AND RATING. DISCONNECT SUPPLY CORD BEFORE CHANGING FUSE
UTILISE UN FUSIBLE DE RECHANGE DE MÊME TYPE. DEBRANCHER AVANT DE REMPLACER LE FUSIBLE
THE FOLLOWING ARE TRADEMARKS/REGISTERED TRADEMARKS OF MACKIE DESIGN INC.: "MACKIE", "MACKIE INDUSTRIAL", & THE "RUNNING MAN" FIGURE
COMMANDS
COMMANDS
(8Ω) Loudspeaker
GND OVERL. 300mA. max
GND OVERL. 300mA. max
BY
BY
1K Ω 1/2W
RESISTOR
LED
RELAY
Note: This illustration demonstrates a typical application using a pair of UP4000 Series Power Amplifiers. A paging microphone and a jukebox are connected to the Balanced Input of Amp 1 via the Mixer, and the Input priority function can be switch-activated to give the paging mic and jukebox priority over the signal source connected to the Unbalanced Input. A preamplifier is connected to the Unbalanced Input, with source selections for an AM/FM Tuner, Cassette or DAT Recorder, and CD Player. The Parallel Out is connected to the Unbalanced Input on a second UP4000 Series. 70V constant-voltage speakers are connected to the 70V tap on Amp 1, and a pair of 8-ohm speakers (connected in parallel for a total impedance of 4 ohms) are connected to the 4Ω tap on Amp 2.

The UNBALANCED IN uses an RCA-type connector. It accepts a line-level signal (–10 dBV) with the SENSITIVITY switch in the 0 dB position (pushed IN). When connecting a low-level signal, push the SENSITIVITY switch OUT (20 dB position). Use high-quality, two-conductor shielded cable to make these connections.
The Input has a balanced screw terminal connector that accepts a line-level signal. The screw terminals should be connected as shown in the following figure:
Connecting the Speakers
The speaker output connectors are screw terminals. Use 16 or 18 gauge wire for connecting the amplifier outputs to the speakers. Strip the wire back about 1/2" inch, loosen the screw enough to loop the wire around the shaft of the screw (clockwise), and tighten down the screw with a slot- head screwdriver.
HOT (+)
If using a 4-ohm speaker, connect the 4Ω output terminal to the "+" terminal on the speaker, and connect the "0" output terminal to the "–" terminal on the speaker.
If using a constant-voltage distributed speaker system, connect either the 25V, 50V, 70V, or 100V output terminal to the "+" side of the speaker system, and connect the "0" output terminal to the "–" side of the speaker system. Make sure that the taps on the speakers add up to no more than the rated power for the UP4000 Series Amplifier being used.
Strip the wire back about 1/2" inch, loosen the screw enough to loop the wire around the shaft of the screw (clockwise), and tighten down the screw with either a slot-head or phillips-head screwdriver.
Use high-quality, three-conductor shielded cable for balanced connections. The better the shield, the better the audio signal is protected from induced EMI and RFI.
If connecting an unbalanced line-level signal to the Input, wire the connections as shown in the following figure:
When the connections have been made, insulate the 50V, 70V, and 100V terminals of the amplifier using the protective cover supplied.
+ –
Connecting the POWER INPUT 24V.D.C.
Connect a 24 VDC power supply to these spring terminals as an alternate method to power the UP4000 Series. To minimize the voltage drop across the wire and prevent overheating, use at least 16 AWG wire for the UP4061, and 14 AWG wire for the UP4121 and UP4161.
HOT (+)

Thermal Considerations
There is one setting that can be changed inside the UP4000 Series Amplifier. This setting should be made prior to installation.
IMPORTANT: The UP4000 Series amplifier is convection cooled rather than fan cooled. Heat is drawn away from the amplifier by the heatsink and radiated through the cooling vents in the top cover. When installing the UP4000 Series, be sure to allow sufficient air space around the top and rear of the amplifier to allow adequate cooling for the heatsink. Leave at least one rack space above and below the UP4000 and at least 6 inches behind the chassis to allow proper ventilation.
CAUTION: These servicing instructions are for use by qualified personnel only. To avoid electric shock, do not perform any servicing other than that contained in the Operating Instructions unless you are qualified to do so. Refer all servicing to qualified service personnel. Make sure the power is off and the power cord disconnected before removing the top cover to gain access to the inside of the UP4000 Series.
If the amplifier should overheat, a thermal switch is activated that turns off the power amplifier, allowing the heatsinks to cool down. The ON indicator on the front panel will remain lit. Once the amplifier has cooled to a safe operating temperature, the thermal switch resets and reactivates the amplifier. If this should occur, identify the cause of the problem and take
Jumper J1 on the input board allows you to enable the Standby function. Standby mode is disabled by default. You must change jumper J1 on the input board to enable the Standby function.
corrective action (i.e., provide better ventilation, install a fan in the rack, make sure the amplifier is not overloaded by too low of a load impedance or by a short circuit on the speaker line).
INPUT BOARD
JP6
J1
STANDBY ENABLED
STANDBY DISABLED (DEFAULT)
UP4000 Series Input Board Jumper
The UP4000 Series draw an average AC line current as indicated on the following chart:
The UP4000 Series can be configured to operate at 115 VAC or 230 VAC. Be sure the VOLTAGE SELECTOR switch on the rear panel is set to the correct position for the AC power supply being used.

COMMANDS STANDBY
An external normally-open switch can be connected between the STANDBY terminal and the GND terminal on the COMMANDS barrier strip on the rear panel. Closing the switch enables the signal to pass through the amplifier, and opening the switch puts the amplifier in standby mode (power on, no signal).
The BALANCED IN accepts a line-level signal. Connect the input source to the BALANCED IN barrier strip screw terminals.
The BALANCED IN has priority over the UNBALANCED IN. The priority function can be activated by connecting a normally-open switch between the input PRIORITY terminal and the GND terminal on the INPUT barrier strip on the rear panel. Closing the switch activates the priority function and mutes the UNBALANCED IN.
OVERL.
Connect an LED or relay between this terminal and the GND terminal to provide an external indication if the overload circuit has been activated. It provides +18 VDC with a maximum output capacity of 300mA when activated. See "Application Diagram" on page 6.
The UNBALANCED IN accepts either a line-level signal (0 dB position) or a low-level signal (20 dB position), using the input SENSITIVITY switch.
The amplifier outputs on the UP4000 Series can be used with a 4-ohm impedance load, or to directly drive a 25V, 50V, 70V, or 100V distributed system (constant-voltage system).
Push in the H.P. switch to engage the high-pass filter, which rolls off frequencies below 300Hz at 12 dB/octave. Low-Pass Filter
Push in the L.P. switch to engage the low-pass filter, which rolls off frequencies above 7kHz at 12 dB/octave. Note: The H.P. and L.P. filters affect both the balanced and unbalanced inputs.
If the UP4000 Series is not being used in a distributed speaker system, you can connect a speaker with a 4-ohm load between the "4Ω" terminal and the "0" terminal.
When using the UP4000 Series in a distributed system, connect the distributed system between the appropriate POWER OUTPUT terminal (25V, 50V, 70V, or 100V) and the "0" terminal. Make sure the speakers in the system are tapped appropriately so they do not exceed the rated power of the amplifier. (AM4060 = 60 watts, AM4120 = 120 watts, AM4160 = 160 watts).
The PARALLEL OUT connector is provided to connect the UNBALANCED IN signal to multiple amplifiers in a daisy-chain configuration.

POWER INPUT 24V D.C.
The UP4000 Series can be powered using a 24 VDC power supply. This can serve as the primary power supply for the UP4000 Series, or as a backup supply in case of an AC power failure. The UP4000 Series seamlessly switches to the backup supply if there is a power loss. When both AC power and 24 VDC power are connected, the AC power is used and no current is drawn from the DC supply.
UP4000 Series Daisy-Chaining Inputs
To Next Amplifier

UP4000 Series Block Diagram
HP
LP HI
LO
7K
10K
INPUT PRIORITY
MUTE
STANDBY
MUTE
PRIORITY
BALANCED IN
STD-BY
COMMANDS
STANDBY
OVERL. +18VDC
OVERLOAD
SIGNAL
100V 70V
50V 25V 4 Ω 0
POWER AMPLIFIER
PEAK MACKIE INDUSTRIAL UP4000 SERIES BLOCK DIAGRAM (#2.02.01.DF)
AUDIO OUTPUT TRANSFORMER
FEEDBACK LOOP
UP4000 Series Specifications
Power Amplifier Section
Continuous Sine Wave Average Output Power, both channels driven:
UP4061: 60 watts RMS nominal; 90 watts peak (10ms) UP4121: 120 watts RMS nominal; 180 watts peak (10ms) UP4161: 160 watts RMS nominal; 220 watts peak (10ms)
50Hz to 15kHz (±3 dB)
> 80 dB below nominal power
Low Impedance: 4Ω Constant Voltage: 25V, 50V, 70V, 100V Unbalanced Out: One unbalanced RCA connector, parallel to Unbalanced In
Control Inputs and Outputs
Inputs: Priority switch, dry contact closure Standby switch, dry contact closure Outputs: Overload Indicator, 18 VDC @ 300mA

6. Service Information
In the event that your UP4000 Series amplifier should require servicing, please follow these instructions:
115 VAC, 60Hz 230 VAC, 50Hz
Model Line Fuse 230 VAC Line Fuse 115 VAC 24 VDC Fuse
UP4060 1.25AT 2.5AT 5AT UP4120 2.5AT 5AT 10AT UP4160 3.15AT 6.3AT 16AT
Height: 3.5" (88mm) Width: 17.0" (431mm) Depth: 12.4" (314mm) Weight: UP4061: 22 lbs. (10.0kg) UP4121: 28 lbs. (12.7kg) UP4161: 31 lbs. (14.1kg)

Mackie Industrial Service Department
One Main Street Whitinsville, MA 01588
Mackie Industrial continually engages in research related to product improvement, new materials, and production methods. Design refinements are introduced into existing products without notice as a routine expression of that philosophy. For this reason, any current Mackie Industrial product may differ in some respect from its published description, but will always equal or exceed the original design specifications unless otherwise stated.
Mackie Industrial is a trademark of Mackie Designs Inc.
All other brand names mentioned are trademarks or registered trademarks of their respective holders, and are hereby acknowledged.
© 2001 All Rights Reserved. Mackie Industrial. Printed in the U.S.A.

www.mackieindustrial.com 16220 Wood-Red Road NE, Woodinville, WA 98072 USA TEL 888.337.7404, FAX 425.487.4337, industrial@mackie.com UK +44.1268.571.212, FAX +44.1268.570.809 +industrial@rcf-uk.com
ITALY +39.0522.354.111, FAX +39.0522.926.208 [email protected] FRANCE +33.3.8546.9160, FAX +33.3.8546.9161 +rcf.com[email protected] GERMANY +49.2572.96042.0, FAX +49.2572.96042.10 [email protected]
Pages referenced in this manual — manufacturer, support and downloads.
Owners and our team usually reply within a day — and your question helps the next person too.
Be the first to ask — other owners or our team will answer.