Instruction/ maintenance manual of the product FR587W Lumex Syatems
Go to page of 24
Series FR587W Delux e Clinical Car e R ec liner , Extr a W ide Series FR587WH Delux e Clinical Car e R ec liner , Extr a W ide, with Hea t and Massa ge Assembl y and Oper a ting Instr uctions IMPORT ANT : READ THIS MANU AL BEFORE OPERA TING Y OUR L UMEX FR587W / FR587WH DEL UXE EXTRA-WIDE CLINICAL CARE RECLINER.
FR587W-INS-LAB-RevC13: Deluxe Extra-Wide Clinical Care Recliner Assembly and Operating Instructions 2 CONTENTS .
FR587W-INS-LAB-RevC13: Deluxe Extra-Wide Clinical Care Recliner Assembly and Operating Instructions 3 INTR ODUCTION This manual contains assembly , operation, and maintenance instructions for the Lumex Clinical Car e Recliners Series FR587W and FR587WH.
FR587W-INS-LAB-RevC13: Deluxe Extra-Wide Clinical Care Recliner Assembly and Operating Instructions 4 .
FR587W-INS-LAB-RevC13: Deluxe Extra-Wide Clinical Care Recliner Assembly and Operating Instructions 5 ASSEMBL Y UNP ACKING 1. Check for obvious damage to the carton or its contents. If damage is evident, please notify the carrier and your Graham-Field authorized distributor .
FR587W-INS-LAB-RevC13: Deluxe Extra-Wide Clinical Care Recliner Assembly and Operating Instructions 6 3. Remove car dboar d shipping r etainers and tape fr om ar ound gas spring cylinders. Rotate the hinge section on the gas spring so that it is perpendicular to the upholster ed back, as shown at right.
FR587W-INS-LAB-RevC13: Deluxe Extra-Wide Clinical Care Recliner Assembly and Operating Instructions 7 8. Raise the upholster ed back to vertical position.
FR587W-INS-LAB-RevC13: Deluxe Extra-Wide Clinical Care Recliner Assembly and Operating Instructions 8 OPERA TION .
FR587W-INS-LAB-RevC13: Deluxe Extra-Wide Clinical Care Recliner Assembly and Operating Instructions 9 side table (stored position) side table (engaged position) tabs engage into slots on side table mo.
FR587W-INS-LAB-RevC13: Deluxe Extra-Wide Clinical Care Recliner Assembly and Operating Instructions 10 SIDE P ANEL OPERA TION For easy cleaning and access to the side and underside of the r ecliner , Lumex Clinical Care Recliners featur e easy-to-r emove side panels.
FR587W-INS-LAB-RevC13: Deluxe Extra-Wide Clinical Care Recliner Assembly and Operating Instructions 11 RECLINER OPERA TION The Lumex Series FR587W and FR587WH Recliners featur e thr ee positions for patient comfort. The four th position is a T r endelenbur g (or Shock Position) that must be activated by a car egiver .
FR587W-INS-LAB-RevC13: Deluxe Extra-Wide Clinical Care Recliner Assembly and Operating Instructions 12 Upright Position First Recline Position (TV Position) Second Recline Position (Full Recline Posit.
FR587W-INS-LAB-RevC13: Deluxe Extra-Wide Clinical Care Recliner Assembly and Operating Instructions 13 GAS SPRING TROUBLESHOO TING GUIDE Info: gas springs have been pre-adjusted at factor y The gas spring on your r ecliner pr ovides counterbalancing for ces, and is self-locking for innite, pr ecise positioning.
FR587W-INS-LAB-RevC13: Deluxe Extra-Wide Clinical Care Recliner Assembly and Operating Instructions 14 L UMEX CLINICAL CARE RECLINERS WITH HEA T AND MASSA GE FEA TURE INST ALLA TION AND OPERA TING GUI.
FR587W-INS-LAB-RevC13: Deluxe Extra-Wide Clinical Care Recliner Assembly and Operating Instructions 15 2. The contr ol module, the brains of the system, is inside the junction box. Both ar e shown at right. 3. The power supply , which has an 8-foot power cor d that plugs into the wall power outlet, is shown at right.
FR587W-INS-LAB-RevC13: Deluxe Extra-Wide Clinical Care Recliner Assembly and Operating Instructions 16 9. Insert the Y -cable connector labeled UPPER into the back cushion cable connector also labeled UPPER until its locking tabs snap into place, as shown at right.
FR587W-INS-LAB-RevC13: Deluxe Extra-Wide Clinical Care Recliner Assembly and Operating Instructions 17 5. The selector switch has THREE HEA T FUNCTION SETTINGS and FOUR MASSAGE FUNCTION SETTINGS as follows: a. HEA T FUNCTION SETTINGS: 1) Pr ess selector switch UP for Setting 1: High Heat , 106°F (41°C), brightest LED.
FR587W-INS-LAB-RevC13: Deluxe Extra-Wide Clinical Care Recliner Assembly and Operating Instructions 18 e. Ar e all cable connections to the contr ol module (in the junction box) in place per the instructions? Ar e the connectors fully engaged? f. Ar e any of the connectors damaged? g.
FR587W-INS-LAB-RevC13: Deluxe Extra-Wide Clinical Care Recliner Assembly and Operating Instructions 19 CARE AND MAINTENANCE .
FR587W-INS-LAB-RevC13: Deluxe Extra-Wide Clinical Care Recliner Assembly and Operating Instructions 20 The information published in this car e guide r efers to the performance of PERMABLOK3 pr oducts in specic tests conducted under laborator y conditions.
FR587W-INS-LAB-RevC13: Deluxe Extra-Wide Clinical Care Recliner Assembly and Operating Instructions 21 • Deter gent and water ar e adequate for cleaning surfaces in nonpatient-car e ar eas (e.g., administrative ofces). Clean and disinfect high-touch surfaces on a more fr equent schedule than minimal-touch housekeeping surfaces.
FR587W-INS-LAB-RevC13: Deluxe Extra-Wide Clinical Care Recliner Assembly and Operating Instructions 22 TECHNICAL SPECIFICA TIONS 50" .
FR587W-INS-LAB-RevC13: Deluxe Extra-Wide Clinical Care Recliner Assembly and Operating Instructions 23 LIMITED WARRANTY GF Health Pr oducts, Inc. (“Graham-Field”) warrants the FR587W Deluxe Extra .
GF Health Pr oducts, Inc. 2935 Nor theast Parkway Atlanta, Georgia 30360 USA T elephone: 770-368-4700 Fax: 770-368-2386 T echnical Suppor t: 770-447-1609 www .
An important point after buying a device Lumex Syatems FR587W (or even before the purchase) is to read its user manual. We should do this for several simple reasons:
If you have not bought Lumex Syatems FR587W yet, this is a good time to familiarize yourself with the basic data on the product. First of all view first pages of the manual, you can find above. You should find there the most important technical data Lumex Syatems FR587W - thus you can check whether the hardware meets your expectations. When delving into next pages of the user manual, Lumex Syatems FR587W you will learn all the available features of the product, as well as information on its operation. The information that you get Lumex Syatems FR587W will certainly help you make a decision on the purchase.
If you already are a holder of Lumex Syatems FR587W, but have not read the manual yet, you should do it for the reasons described above. You will learn then if you properly used the available features, and whether you have not made any mistakes, which can shorten the lifetime Lumex Syatems FR587W.
However, one of the most important roles played by the user manual is to help in solving problems with Lumex Syatems FR587W. Almost always you will find there Troubleshooting, which are the most frequently occurring failures and malfunctions of the device Lumex Syatems FR587W along with tips on how to solve them. Even if you fail to solve the problem, the manual will show you a further procedure – contact to the customer service center or the nearest service center