EN
Lumens Technology logo
Official user manual

Lumens Technology PC170

42 pages·1.7 MB·Camera Accessories·PDF·ENDEFRITNLJA
Lumens Technology PC170
Table of Contents 80 sections PC170 Document Camera · User Manual - English · [Important] · driver, etc., please visit Lumens http://www.Mylumens.com/goto.htm · … ShowHide
PC170 Document Camerap.1User Manual - Englishp.1[Important]p.1driver, etc., please visit Lumens http://www.Mylumens.com/goto.htmp.1Copyright Informationp.4Chapter 1 Safety Instructionsp.5Precautionsp.6FCC Warningp.6EN55022 (CE Radiation) Warningp.6Chapter 2 Package Contentsp.7Chapter 3 Product Overviewp.83.1 Relative position of the presenter and documentp.9Chapter 4 Installation and Connectionsp.104.1 System diagramp.10TVp.104.2 Installation and setupp.11VGA Cablep.114.4 Connecting to a computer and use Lumens™ softwarep.124.5 Connecting to a computer and projector or monitor simultaneouslyp.12Computerp.124.6 Connect to a PC and read the SD cardp.13SD Cardp.13USB Cablep.134.8 Connecting to an HDTVp.14HDTVp.144.9 Connecting to a speakerp.144.10 Connecting to a Computer with RS232p.15EXTENDERp.15AC Outlet Computerp.154.11 Connecting to a TVp.154.12 Installing application softwarep.16Chapter 5 Start Usingp.17Chapter 6 Control Panel/Remote Control and Setting Menup.186.1 Functions of control panel and remote controlp.18AUTO TUNEp.18BRT+/-p.18CAPTUREp.18/DELp.18ENTERp.18ENTER /p.18FREEZEp.18LAMPp.18MASKp.19MENUp.19PANp.19PIPp.19PLAYBACKp.19RECORDp.19ROTATEp.19SOURCEp.19ZOOM +/-p.196.2 Setting Menup.206.2.1 Main menup.206.2.2 Set up menup.216.2.3 MASK Mode Setting Menup.236.2.4 Spotlight Mode Setting Menup.24Chapter 7 Descriptions of major functionsp.25Use the remote control or control panel:p.257.2 I would like to switch image sourcesp.257.3 I would like to switch the image modep.257.4 I would like to make text clearer and photos more colorfulp.257.4.1 Photo/Text mode descriptionsp.257.5 I would like to zoom in/out imagesp.267.6 I would like to use the auto focusp.267.7 I would like to adjust the brightnessp.26Control panel:p.267.8 I would like to turn on/off the lampp.267.9 I would like to freeze imagesp.277.10 I would like to rotate the imagep.277.11 I want to capture imagesp.277.11.1 Capture and save imagesp.277.11.2 Setting the quality of captured imagesp.277.11.3 Setting continuous capturep.287.12 I would like to record videosp.287.12.2 Setting the quality of captured imagesp.297.12.4 Playing videosp.297.13 I would like to view captured/recorded imagesp.297.14 I would like to delete the captured/recorded imagesp.307.16 I would like to enlarge a part of the image (PAN)p.30Remote control:p.30
Page 1 of the Lumens Technology PC170 user manual — driver, etc., please visit Lumens http://www.Mylumens.com/goto.htm
Page 1 · click to enlarge
Page 1

PC170 Document Camera

User Manual - English

Lumens Technology PC170 — PC170 Document Camera diagram (page 1)
Fig. 1 · PC170 Document Camera

[Important]

To download the latest version of Quick Start Guide, multilingual user manual, software, or

driver, etc., please visit Lumens http://www.Mylumens.com/goto.htm

Page 2 of the Lumens Technology PC170 user manual — PC170 Document Camera
Page 2 · click to enlarge
Page 2
Page 2 of the Lumens Technology PC170 user manual — PC170 Document Camera
Page 3 of the Lumens Technology PC170 user manual — 9.1 Connecting to a projector or monitor ............................................................ 38
Page 3 · click to enlarge
Page 3

7.6 I would like to use the auto focus 25

7.7 I would like to adjust the brightness 25

7.8 I would like to turn on/off the lamp 25

7.9 I would like to freeze images 26

7.10 I would like to rotate the image 26

7.11 I want to capture images 26

7.12 I would like to record videos 27

7.13 I would like to view captured/recorded images 28

7.14 I would like to delete the captured/recorded images 29

7.15 I would like to automatically delete the stored images whenever it is

turned off (Auto Erase) 29

7.16 I would like to enlarge a part of the image (PAN) 29

7.17 I would like to use the MASK and Spotlight function 30

7.18 I would like to play the slides (Slide Show) 31

7.19 I would like to compare images (compare live images with stored images

(PIP)) 32

7.20 I would like to reduce the image noise (Projector Type) 32

7.21 I would like to resume the factory default settings (Factory Reset) 33

7.22 I would like to change the splash screen 33

7.23 I would like to use a SD card 34

7.24 Computer-related functions 34 Chapter 8 Connecting to Microscope 37 Chapter 9 DIP Switch Settings 38

9.1 Connecting to a projector or monitor 38

9.2 Connecting to a TV ...................................................................................... 39 Chapter 10 Troubleshooting ...................................................................................... 40

Page 4 of the Lumens Technology PC170 user manual — Copyright Information
Page 4 · click to enlarge
Page 4

Copyright Information

Copyrights © Lumens Digital Optics Inc. All rights reserved.

Lumens is a trademark that is currently being registered by Lumens Digital Optics Inc.

Copying, reproducing or transmitting this file is not allowed if a license is not provided by

Lumens Digital Optics Inc. unless copying this file is for the purpose of backup after

purchasing this product.

In order to keep improving the product, Lumens Digital Optics Inc. hereby reserves the right

to make changes to product specifications without prior notice. The information in this file is

subject to change without prior notice.

To fully explain or describe how this product should be used, this manual may refer to

names of other products or companies without any intention of infringement.

Disclaimer of warrantiesLumens Digital Optics Inc. is neither responsible for any possible

technological, editorial errors or omissions, nor responsible for any incidental or related

damages arising from providing this file, using, or operating this product.

Page 5 of the Lumens Technology PC170 user manual — Chapter 1 Safety Instructions
Page 5 · click to enlarge
Page 5

Chapter 1 Safety Instructions

Always follow these safety instructions when setting up and using the Document Camera:

1. Do not place Document Camera in tilted position. 2. Do not place the Document Camera on an unstable trolley, stand or table. 3. Do not use the Document Camera near water or source of heat. 4. Use attachments only as recommended. 5. Use the type of power source indicated on the Document Camera. If you are not sure of the type of power available, consult your dealer or local electricity company for advice. 6. Place the Document Camera on a place that it can be unplugged easily. 7. Always take the following precautions when handling the plug. Failure to do so may result in sparks or fire. Ensure the plug is free of dust before inserting it into a socket. Ensure that the plug is inserted into the socket securely. 8. Do not overload wall sockets, extensions leads or multi-way plug boards as this may cause fire or electric shock. 9. Do not place the Document Camera where the cord can be stepped on as this may result in fraying or damage to the lead or the plug. 10. Unplug the Document Camera from the wall socket before cleaning. Use a damp cloth for cleaning. Do not use liquid or aerosol cleaners. 11. Do not block the slots and openings in the Document Camera case. They provide ventilation and prevent the Document Camera from overheating. Do not place the Document Camera on a sofa, rug or other soft surface or in a built-in installation unless proper ventilation is provided. 12. Never push objects of any kind through cabinet slots. Never allow liquid of any kind to spill into the Document Camera. 13. Except as specifically instructed in this User Manual, do not attempt to operate this product by yourself. Opening or removing covers may expose you to dangerous voltages and other hazards. Refer all servicing to licensed service personnel. 14. Unplug the Document Camera during thunderstorms or if it is not going to be used for an extended period. Do not place the Document Camera or remote control on top of heat-emitting equipment or heated objects such as a car, etc. 15. Unplug the Document Camera from the wall outlet and refer serving to licensed service personnel when the following situations happen: If the power cable or plug becomes damaged or frayed. If liquid is spilled into it or the Document Camera has been exposed to rain or

water.

<Note> Using an incorrect battery type in the remote control may result in

breakdown. Follow your country’s instructions on how to dispose of used batteries.

Page 6 of the Lumens Technology PC170 user manual — EN55022 (CE Radiation) Warning
Page 6 · click to enlarge
Page 6

Precautions

rain or moisture.

This Document Camera has a 3-wire AC line Plug. This is a safety feature to ensure that

the plug will fit into the power outlet. Do not try to disable this safety feature.

If the Document Camera will not be used for an extended time, unplug it from the power

socket.

Risk of Electric Shock

This symbol indicates that this equipment may contain dangerous voltage which could cause electric shock.

This symbol indicates that there are important operating and maintenance instructions in this User Manual with this unit.

FCC Warning

This Document Camera has been tested and found to comply with the limits for a Class A

digital device, pursuant to Part 15 of FCC Rules. These limits are designed to provide

reasonable protection against harmful interference in a residential installation.

EN55022 (CE Radiation) Warning

This product is intended for use in a commercial, industrial, or educational environment. It

is not intended for residential use.

This is a Class A product. In a residential environment it may cause radio interference, in

which case the user may be required to take adequate measures. The typical use is in a

conference room, meeting room or auditorium.

Page 7 of the Lumens Technology PC170 user manual — Chapter 2 Package Contents
Page 7 · click to enlarge
Page 7

Chapter 2 Package Contents

PC170 Quick Start Guide 4-Steps Card

(For download of other language versions, please

Lumens Technology PC170 — Chapter 2 Package Contents diagram (page 7)
Fig. 2 · Chapter 2 Package Contents

VGA Cable USB Cable Power Cord

Lumens Technology PC170 — Chapter 2 Package Contents diagram (page 7)
Fig. 3 · Chapter 2 Package Contents

Appearance may vary depending on country/region

Remote Control Remote Control Holder Microscope Adapter

visit Lumens website) · · Accessory Pouch

Page 8 of the Lumens Technology PC170 user manual — Chapter 3 Product Overview
Page 8 · click to enlarge
Page 8

Chapter 3 Product Overview

1. Gooseneck
2. AF button
4. Control panel
5. LED indicator
6. Built-in Microphone
7. Remote sensor
Lumens Technology PC170 — Chapter 3 Product Overview diagram (page 8)
Fig. 4 · Chapter 3 Product Overview
8. Lens
9. LED lamp
10. DIP Switch Settings

3 Lamp · (Bottom)

Page 9 of the Lumens Technology PC170 user manual — 3.1 Relative position of the presenter and document
Page 9 · click to enlarge
Page 9

3.1 Relative position of the presenter and document

Lumens Technology PC170 — 3.1 Relative position of the presenter and document diagram (page 9)
Fig. 5 · 3.1 Relative position of the presenter and document
Page 10 of the Lumens Technology PC170 user manual — TV
Page 10 · click to enlarge
Page 10

Chapter 4 Installation and Connections

4.1 System diagram

Lumens Technology PC170 — 4.1 System diagram diagram (page 10)
Fig. 6 · 4.1 System diagram
Lumens Technology PC170 — 4.1 System diagram diagram (page 10)
Fig. 7 · 4.1 System diagram

TV

Show 4 more labels / short text on this page
Projector or Monitor · Earphone or · Speaker · Computer SD Card
Page 11 of the Lumens Technology PC170 user manual — VGA Cable
Page 11 · click to enlarge
Page 11
Lumens Technology PC170 — 4.2 Installation and setup diagram (page 11)
Fig. 8 · 4.2 Installation and setup

4.2 Installation and setup

1. Please set up the DIP Switch Settings first. Refer to Chapter 9 DIP Switch Settings in the DC190 User Manual. 4.3 Connecting to a projector or monitor
Lumens Technology PC170 — 4.2 Installation and setup diagram (page 11)
Fig. 9 · 4.2 Installation and setup

VGA Cable

Show 5 more labels / short text on this page
Monitor or HDTV · Power Cord · Monitor or · Projector · AC Outlet
Page 12 of the Lumens Technology PC170 user manual — Computer
Page 12 · click to enlarge
Page 12

4.4 Connecting to a computer and use Lumens™ software

Lumens Technology PC170 — 4.4 Connecting to a computer and use Lumens™ software diagram (page 12)
Fig. 10 · 4.4 Connecting to a computer and use Lumens™ softwar…

VGA Cable

Driver and software can be downloaded from Lumens website

4.5 Connecting to a computer and projector or monitor simultaneously

Lumens Technology PC170 — 4.5 Connecting to a computer and projector or monitor simultaneously diagram (page 12)
Fig. 11 · 4.5 Connecting to a computer and projector or monito…

VGA Cable

VGA Cable

Press [SOURCE] button to switch the image source.

Computer

Show 9 more labels / short text on this page
USB Cable · Projector · Power Cord · AC Outlet · Computer · Power Cord · Monitor or · Projector · AC Outlet
Page 13 of the Lumens Technology PC170 user manual — VGA Cable
Page 13 · click to enlarge
Page 13

4.6 Connect to a PC and read the SD card

Lumens Technology PC170 — 4.6 Connect to a PC and read the SD card diagram (page 13)
Fig. 12 · 4.6 Connect to a PC and read the SD card

SD Card

Computer

<Note> Connected to a computer and turned off, the Document Camera is just

regarded as an external storage device. 4.7 Connecting to an Interactive Whiteboard (IWB)

Lumens Technology PC170 — SD Card diagram (page 13)
Fig. 13 · SD Card

VGA Cable

USB Cable

Computer

Show 7 more labels / short text on this page
USB Cable · Power Cord · AC Outlet · Projector · USB Cable · Power Cord · AC Outlet
Page 14 of the Lumens Technology PC170 user manual — HDTV
Page 14 · click to enlarge
Page 14

4.8 Connecting to an HDTV

Lumens Technology PC170 — 4.8 Connecting to an HDTV diagram (page 14)
Fig. 14 · 4.8 Connecting to an HDTV

HDTV

4.9 Connecting to a speaker

Lumens Technology PC170 — HDTV diagram (page 14)
Fig. 15
Show 6 more labels / short text on this page
Power Cord · HDMI Cable · AC Outlet · Power Cord · Earphone or Speaker · AC Outlet
Page 15 of the Lumens Technology PC170 user manual — EXTENDER
Page 15 · click to enlarge
Page 15

4.10 Connecting to a Computer with RS232

Lumens Technology PC170 — 4.10 Connecting to a Computer with RS232 diagram (page 15)
Fig. 16 · 4.10 Connecting to a Computer with RS232

EXTENDER

AC Outlet Computer

After connecting to the RS232 cable, you can use RS232 commands to control

PC170.

4.11 Connecting to a TV

Lumens Technology PC170 — 4.11 Connecting to a TV diagram (page 15)
Fig. 17 · 4.11 Connecting to a TV

EXTENDER

NTSCUSA, Canada, Mexico, Panama, Chile, Japan, Taiwan, Korea, and
Show 8 more labels / short text on this page
Adapter · Power Cord · RS232 Adapter · DIP Switch Settings · Adapter · Power Cord · C-Video Cable · AC Outlet
Page 16 of the Lumens Technology PC170 user manual — 4.12 Installing application software
Page 16 · click to enlarge
Page 16

Philippines. PAL: Countries/regions not listed above.

<Note> You should unplug and reconnect the power cord, and then restart the

machine for DIP Switch Settings to take effect. Once C-VIDEO is on, VGA OUT is

not supported.

<Note> Only the live image can be displayed in C-Video Out mode.

4.12 Installing application software

The application software installed on the computer enables you to:

Control the PC170. Capture and record images. Annotate the image, highlight important details and save it. Support the full screen function.

<Note> Please refer to Podium View™ software user manual for installation steps

and software operation.

Page 17 of the Lumens Technology PC170 user manual — Chapter 5 Start Using
Page 17 · click to enlarge
Page 17

Chapter 5 Start Using

Lumens Technology PC170 — Chapter 5 Start Using diagram (page 17)
Fig. 18 · Chapter 5 Start Using
1. Place an object to be displayed under

the camera.

2. Turn on Power
3. Adjust the gooseneck and lens to the

appropriate positions.

4. Press [AUTO TUNE]

optimize the image. You are ready to

teach/present.

Each time the camera head is moved,

please locate it and then press

[FOCUS] to refocus the lens.

When using the remote control, aim at the remote sensor on the PC170, and

press the power button.

Once PC170 is turned on, the LED on the control panel will flash a few times

and stay lit. Please contact your distributor if the LED is not on.

button to

Page 18 of the Lumens Technology PC170 user manual — LAMP
Page 18 · click to enlarge
Page 18

Chapter 6 Control Panel/Remote Control and Setting Menu

6.1 Functions of control panel and remote control

<Remark> The below functions are listed alphabetically.

Name Function Descriptions Operation

Turn on and off the Document Camera. Remote control /Control panel

,,, Move up, down, left or right to select the needed function.

Remote control /Control panel

FOCUS AF Button. Either sides of the lens

Automatically adjust the image to have the best brightness and focusing performance. Remote control /Control panel

AUTO TUNE

BRT+/-

Adjust the brightness of the image.

CAPTURE

Capture images to SD card (priority) or internal memory card. Control panel

Capture and save images to the SD Card (priority) or internal memory card while displaying live images. Delete files from the SD Card (priority) or internal memory while reading the stored files (in Playback mode).

CAPTURE

/DEL

ENTER

Enter/Activate functions.

ENTER /

Live imageFreeze the current image OSD Mode: Enter/Activate functions Control panel

FREEZE

Freeze the current image to remain temporarily on the screen. Press again to defreeze. Remote control

FREEZE

Lamp mode toggle switch. Remote control /Control panel

LAMP

Show 4 more labels / short text on this page
Remote control · / · Remote control · Remote control
Page 19 of the Lumens Technology PC170 user manual — ZOOM +/-
Page 19 · click to enlarge
Page 19

Enter Mask/Spotlight mode.

MASK

MENU

Activate the setting menu/exit the menu. Remote control /Control panel

PAN

Enable/Disable the Partial Enlarged mode.

PIP

Image comparison (to compare live images with stored image files). Remote control

PLAYBACK

Read files stored in the SD Card (priority) or internal memory. Remote control /Control panel

Record motion images. Press [RECORD] to record images to SD Card, and then press [RECORD] again to stop recording.

RECORD

ROTATE

Switch between different sources of signals:

SOURCE

1. Live images (default).

Remote control /Control panel

2. Computer.

<Remark> This button is disabled in C-VIDEO Out mode.

ZOOM +/-

Increase or decrease the image size. Remote control /Control panel

Show 7 more labels / short text on this page
Remote control · Remote control · / · Remote control · Screen rotation 0°/180°/Flip/Mirror · Remote control · /
Page 20 of the Lumens Technology PC170 user manual — 6.2.1 Main menu
Page 20 · click to enlarge
Page 20

6.2 Setting Menu

6.2.1 Main menu

<Remark> Press [MENU] on the remote control or control panel to display the setting

menu.

Lumens Technology PC170 — 6.2.1 Main menu diagram (page 20)
Fig. 19 · 6.2.1 Main menu

Auto Tune Automatically adjust the image to have the best brightness and focusing performance.

Slide Show Show the photos or videos stored in the SD card (priority) or internal memory in slide mode.

PAN Enable/Disable the Partial Enlarged mode.

Manual Focus AF Button.

LAMP Lamp mode toggle switch.

Rotate Screen rotation 0°/180°/Flip/Mirror

PIP Image comparison (to compare live images with stored image files).

Settings Set up various functions.

Brightness Adjust the brightness of the image.

Photo/Text Select Photo/Text/Gray Mode.

Mask Activate the mask mode.

Zoom Increase or decrease the image size.

Mode Select image mode.

Spotlight Activate the spotlight mode.

Page 21 of the Lumens Technology PC170 user manual — 6.2.2 Set up menu
Page 21 · click to enlarge
Page 21

6.2.2 Set up menu

1st Level Major Items

2nd Level Minor Items

3rd Level Adjustment values Function Descriptions

Single Capture / Time

Press left and right arrow keys to select capture mode.

Lapse / Record / Disable

1. 1 hr
2. 2 hr 3. 4 hr 4. 8 hr 5. 24 hr 6. 48 hr 7. 72 hr

Use the left and right arrow keys to select the capture time. <Note> This will be active only when capture mode is set to timer

1. 3 Sec 2. 5 Sec
3. 10 Sec 4. 30 Sec 5. 1 Min. 6. 2 Min. 7. 5 Min.

Use the left and right arrow keys to select the capture interval. <Note> This will be active only when capture mode is set to timer

1. High 2. Medium

Use the left and right arrow keys to select the image quality for the captured images and recorded videos

3. Low

Show the photos or videos stored in the SD card (priority) or internal memory in slide mode.

1. 0.5 Sec 2. 1 Sec

Use the left and right arrow keys to select the delay time. Select manual mode to switch images manually.

3. 3 Sec 4. 5 Sec 5. 10 Sec 6. Manual

Use the left and right arrow keys to select, and then press [ENTER] to confirm to copy files from internal memory to SD Card.

Copy To SD Card Enter

Use the left and right arrow keys to select, press [ENTER] to confirm the deletion of all images from the SD Card (priority) or internal memory.

Delete All Yes/No

Use the left and right arrow keys to select, and then press [ENTER] to format the SD Card (priority) or internal memory.

Show 10 more labels / short text on this page
Capture Mode · Capture Time · Capture · Settings · Capture Interval · Image Quality · Slide Show Enter · Delay · Storage · Format Yes/No
Page 22 of the Lumens Technology PC170 user manual — 6.2.2 Set up menu
Page 22 · click to enlarge
Page 22

Regardless of outside environment, the machine will adjust the brightness to the optimal condition. Use the left and right arrow keys to select.

Auto Exposure On/Off

Regardless of outside light or color, the machine will adjust the color to the optimal condition; Press [ENTER] to activate.

Audio Volume 0~A~Max Use the left and right arrow keys to adjust the volume.

Use the left and right arrow keys to select the projector type and reduce image noise.

Projector Type DLP/LCD

Digital Zoom On/Off Use the left and right arrow keys to turn on/off digital zoom.

1. English 2. 繁體中文 3. 简体中文 4. Deutsch 5. Français 6. Español 7. Русский 8. Nederlands 9. Suomi 10. Polski 11. Italiano 12. Português 13. Svenska 14. dansk 15. ČESKY 16. العربية 17. 日本語 18. 한국의 19. ελληνικά

English 繁體中文 简体中文 Deutsch Français Español Русский Nederlands Suomi Polski Italiano Português Svenska dansk ČESKY العربية 日本語 한국의 ελληνικά Use the left and right arrow keys in the Language option to select the preferred language.

Use the left and right arrow keys to turn on/off the lock down function. You can set the password when [On] is selected.

Lock Down On/Off

Use the left and right arrow keys to enable/disable Auto Erase. When [On] is selected, the stored images will automatically be deleted when the system is turned off.

Auto Erase On/Off

Read the value of the current image mode. Use the left and right arrow keys to select, and then confirm by pressing [ENTER].

Preset Load Yes/No

Show 6 more labels / short text on this page
Auto White · Enter · Balance · Control · Language · Advanced
Page 23 of the Lumens Technology PC170 user manual — 6.2.3 MASK Mode Setting Menu
Page 23 · click to enlarge
Page 23
Lumens Technology PC170 — 6.2.3 MASK Mode Setting Menu diagram (page 23)
Fig. 20 · 6.2.3 MASK Mode Setting Menu

Read the value of the current image mode. Use the left and right arrow keys to select, and then confirm by pressing [ENTER].

Use the left and right arrow keys to select, and then confirm by pressing [ENTER] to restore the factory defaults.

6.2.3 MASK Mode Setting Menu

Lumens Technology PC170 — 6.2.3 MASK Mode Setting Menu diagram (page 23)
Fig. 21 · 6.2.3 MASK Mode Setting Menu

Live Enter Press [ENTER] to return to live image.

Transparency 0~2~3 Adjust the transparency of the mask using left and right arrow keys.

Step Large/Medium/Small Select the step distance of the mask using left and right arrow keys.

V Size 0~A~Max Adjust the vertical height of the mask using left and right arrow keys.

H Size 0~A~Max Adjust the horizontal length of the mask using left and right arrow keys.

Press [ENTER] key to confirm your selection and exit the mask mode OSD menu.

Page 24 of the Lumens Technology PC170 user manual — 6.2.4 Spotlight Mode Setting Menu
Page 24 · click to enlarge
Page 24

6.2.4 Spotlight Mode Setting Menu

2nd Level Major Items

4th Level Adjustment values Function Descriptions

Live Enter Press [ENTER] to return to live image. Shape Ellipse/Rectangle

Transparency 0~2~3 Adjust the transparency of the border in the Spotlight mode using left and right arrow keys.

Select the step distance of the spotlight zone using left and right arrow keys.

Step Large/Medium/Small

V Size 0~A~Max Adjust the height of the spotlight zone using left and right arrow keys.

H Size 0~A~Max Adjust the width of the spotlight zone using left and right arrow keys.

Press [ENTER] key to confirm your selection and exit the spotlight mode OSD menu. 6.2.5 Splash Setting Windows

Lumens Technology PC170 — 6.2.4 Spotlight Mode Setting Menu diagram (page 24)
Fig. 22 · 6.2.4 Spotlight Mode Setting Menu

Power On Image Setting Default/Customer Select to use default Power On Video

or custom Power On Image Power On Logo Show Time 4 ~ 30 seconds Set up Image display time

Select Power On Image. Only pictures in JPEG format are supported

Press [ENTER] key to confirm your selection and exit Splash Screen Settings window.

Show 5 more labels / short text on this page
3rd Level · Minor Items · Spotlight · Mode · Exit Enter
Page 25 of the Lumens Technology PC170 user manual — 7.4.1 Photo/Text mode descriptions
Page 25 · click to enlarge
Page 25

Chapter 7 Descriptions of major functions

7.1 I would like to automatically adjust the image to have the best brightness and focusing performance

Use the remote control or control panel:

1. Press [AUTO TUNE] for the optimal brightness and focal length.

7.2 I would like to switch image sources

Live image is the default image source. Press [SOURCE]

on the remote control or control panel to have PC170 switch among the following images sources:

1. Live images (default).
2. Computer.

<Remark> This image switch applies to VGA OUT only.

7.3 I would like to switch the image mode

Use the remote control or control panel:

1 Press [MENU] to enter the setting menu.

2 Press [], [], [], or [] to select [Image mode].

3 Press [] or [] to the [Normal/Film/Slide/Microscope].

4 Press [MENU] to exit.

7.4 I would like to make text clearer and photos more colorful

7.4.1 Photo/Text mode descriptions

The default [Photo/Text] mode is in Photo (Photo mode). To change this setting,

please use the remote control or the control panel to enter the Options of the

Setting Menu.

[Photo] (default): for viewing photos or text with photos, making photos more colorful. [Text]: for viewing text files, making the text clearer. [Gray]: for viewing black & white photos which will make the grayscale differentiation distinct.

Page 26 of the Lumens Technology PC170 user manual — 7.8 I would like to turn on/off the lamp
Page 26 · click to enlarge
Page 26

7.4.2 Setting Photo/Text mode

To change the settings, please use the remote control or the control panel:

1. Press [MENU] to enter the setting menu.
2. Press [ ], [ ], [ ], or [ ] to select [Photo/Text]. (Please refer to 7.4.1 Photo/Text

mode descriptions to make the best choice.)

3. Press [ENTER] key to enter.
4. Press [ ] or [ ] to select the [Photo/Text/Gray].
5. Press [MENU] to exit.

7.5 I would like to zoom in/out images

1. Press [ZOOM+] on the remote control or control panel to zoom in images.
2. Press [ZOOM-] on the remote control or control panel to zoom out images.

7.6 I would like to use the auto focus

1. Press the [FOCUS] AF button on the right side of the lens.

7.7 I would like to adjust the brightness

Remote control:

1. Press [BRT +] to make it brighter.
2. Press [BRT -] to make it darker.

Control panel:

1. Press [MENU] to enter the setting menu.
2. Press [ ], [ ], [ ], or [ ] to select [Brightness].
3. Press [ENTER] key to enter.
4. Press [ ] or [ ] to adjust the brightness.
5. Press [MENU] to exit.

7.8 I would like to turn on/off the lamp

The default of the lamp is OFF. When using the remote control or control panel:

1. Press [LAMP] to switch ON/OFF. (The sequence of switching is: OFF/Arm
Page 27 of the Lumens Technology PC170 user manual — 7.11.2 Setting the quality of captured images
Page 27 · click to enlarge
Page 27

7.9 I would like to freeze images

1. Press [FREEZE] on the remote control or control panel to freeze the current image on the screen. Press again to defreeze.

7.10 I would like to rotate the image

Remote control:

1. Press [ROTATE] key to turn the screen. (The sequence of switching is: 0°/180°/Flip/Mirror) Control panel:
1. Press [MENU] to enter the setting menu.
2. Press [ ], [ ], [ ], or [ ] to select [Rotate].
3. Press [ENTER] key to enter.
4. Press [ ] or [ ] to toggle switch rotation model. (The sequence of switching is: 0°/180°/Flip/Mirror)
5. Press [MENU] to exit.

7.11 I want to capture images

7.11.1 Capture and save images

1. Press [CAPTURE] on the remote control or control panel to capture and save images.

You cannot capture images when the capture mode is set to [Disable].

If it is set to [Continuous], you can capture images continuously. Press [Capture] to start capturing continuously, or press [Capture] again to exit.

To change the quality of captured images, please refer to 7.11.2

Setting the quality of captured images.

To change the settings of captured images, please refer to 7.11.3

Setting continuous capture.

7.11.2 Setting the quality of captured images

1. Press [Menu] on the remote control or control panel to enter the setting

light/Dual light/Head light)

Page 28 of the Lumens Technology PC170 user manual — 7.12 I would like to record videos
Page 28 · click to enlarge
Page 28

menu.

2. Press [ ], [ ], [ ], or [ ] to select [Setting].
3. Press [ENTER] key to enter.
4. Press [ ] or [ ] to the [Capture Settings] menu.
5. Press [ ] to find [Image Quality].
6. Press [ ] or [ ] to select among [High/Medium/Low].
7. Press [Menu] to exit.

7.11.3 Setting continuous capture

1. Press [MENU] on the remote control or control panel to enter the setting menu.
2. Press [ ], [ ], [ ], or [ ] to select [Setting].
3. Press [ENTER] key to enter.
4. Press [ ] or [ ] to the [Capture Settings] menu.
5. Press [ ] to the [Capture Mode].
6. Press [ ] or [ ] to select [Timer].
7. Press [ ] to find [Capture Time]; Press [ ] or [ ] to set capture time.
8. Press [ ] to find [Capture Interval]; Press [ ] or [ ] to set interval time.
9. Press [MENU] to exit.

7.12 I would like to record videos

<Remark> You may not record videos until a SD card is inserted. 7.12.1 Recording motion images

<Remark> You may not be able to capture or record images when [Capture Mode] is set to [Disable].

Remote control:

1. Press [RECORD] on the remote control to start recording videos.
2. Record sounds with the built-in microphone of the control panel.
3. Press [RECORD] again to stop recording.

Control panel:

1. Press and hold [CAPTURE] for about 2 seconds to start recording videos.
2. Press [CAPTURE] again to stop recording.
Page 29 of the Lumens Technology PC170 user manual — 7.13 I would like to view captured/recorded images
Page 29 · click to enlarge
Page 29

7.12.2 Setting the quality of captured images

1. Press [Menu] on the remote control or control panel to enter the setting menu.
2. Press [ ], [ ], [ ], or [ ] to select [Setting].
3. Press [ENTER] key to enter.
4. Press [ ] or [ ] to the [Capture Settings] menu.
5. Press [ ] to find [Image Quality].
6. Press [ ] or [ ] to select among [High/Medium/Low].
7. Press [Menu] to exit.

7.12.3 Recording setup

1. Press [MENU] on the remote control or control panel to enter the setting menu.
2. Press [ ], [ ], [ ], or [ ] to select [Setting].
3. Press [ENTER] key to enter.
4. Press [ ] or [ ] to the [Capture Settings] menu.
5. Press [ ] to the [Capture Mode].
6. Press [ ] or [ ] to select [Record].
7. Press [MENU] to exit.

<Remark> When [Capture Mode] is set to [Record], the function of [CAPTURE] on the Control Panel is changed to Image Recording.

7.12.4 Playing videos

For playing videos, please refer to 7.13 I would like to view

captured/recorded images.

7.13 I would like to view captured/recorded images

1. Press [PLAYBACK] on the remote control or control panel to display thumbnails of all stored files.
2. Press [ ], [ ], [ ], or [ ] to select the thumbnail you want to play.
3. Press [ENTER] for full-screen play.
4. When the Video is played, it can be Paused/Played by pressing [Freeze].
5. Press [ ] or [ ] to select the next or previous Audio/Video File.
6. Press [ ] or [ ] to adjust the volume of the video.
Page 30 of the Lumens Technology PC170 user manual — Remote control:
Page 30 · click to enlarge
Page 30
7. Press [PLAYBACK] to return to the Thumbnail Mode to select other Audio/Video Files, or press [MENU] to exit.

<Note> An external speaker must be connected to AUDIO OUT to play sound when you use VGA OUT.

7.14 I would like to delete the captured/recorded images

Use Remote control:

1. Press [PLAYBACK] to show the thumbnails of all stored files.
2. Press [ ], [ ], [ ], or [ ] to select the file you want to delete.
3. Pressing [DELETE] will open a [Delete File] window.
4. Press [ ] or [ ] to select [Yes].
5. Press [ENTER] to delete the selected file.
6. Press [MENU] to exit.

7.15 I would like to automatically delete the stored images whenever it is turned off (Auto Erase)

Use the remote control or control panel:

1. Press [MENU] to enter the setting menu.
2. Press [ ], [ ], [ ], or [ ] to select [Setting].
3. Press [ENTER] key to enter.
4. Press [ ] or [ ] to the [Advanced] menu.
5. Press [ ] or [ ] to [Auto Erase].
6. Press [ ] or [ ] to select [On].
7. Press [MENU] to exit.

7.16 I would like to enlarge a part of the image (PAN)

Remote control:

1. Press [PAN] to enter the Partial Enlarged mode.
2. Press [ ], [ ], [ ], or [ ] to move and view the partial enlarged images.
3. Press [PAN] to exit the partial enlarged mode. Operate with Menu:
1. Press [MENU] to enter the setting menu.
Page 31 of the Lumens Technology PC170 user manual — Operate with Menu:
Page 31 · click to enlarge
Page 31
2. Press [ ], [ ], [ ], or [ ] to select [PAN].
3. Press [ENTER] to activate.
4. Press [ ], [ ], [ ], or [ ] to move and view the partial enlarged images.
5. Press [MENU] to exit the partial enlarged mode.

7.17 I would like to use the MASK and Spotlight function

7.17.1 I would like to use the MASK or Spotlight mode Use Remote Control:

1. Press [MASK] key to enter the Mask/Spotlight mode menu. Press [ ] or [ ] to

select mode.

2. Press [ ] or [ ] or [ ] or [ ] to move the zone position.
3. Press [MASK] again to exit and return to the live image screen.

Operate with Menu:

1. Press [MENU] to enter the setting menu.
2. Press [ ] or [ ] or [ ] or [ ] to select [Mask], Press [ENTER] to enter mask

mode or select [Spotlight] and press [ENTER] key to enter Spotlight mode.

3. Press [MENU] to enter the image OSD menu.
4. Press [ ] or [ ] to select [Live].
5. Press [ENTER] to return to Live Image.

7.17.2 I would like to set the size of Mask I would like to use the Remote under the mask mode:

1. Press [MENU] to enter the image OSD menu.
2. Press [ ] or [ ] to select the item to be modified [Transparency/Step/V Size/H

Size]. (For details, please refer to 6.2 Setting Menu.)

3. Press [ ] or [ ] to perform the modification.
4. Press [MENU] to exit the image OSD menu and return to the Mask mode.

7.17.3 I would like to set Spotlight function Use the Remote under Spotlight mode:

1. Press [MENU] to enter the image OSD menu.
Page 32 of the Lumens Technology PC170 user manual — 7.18.2 Activating/Pausing/Stopping the slide show
Page 32 · click to enlarge
Page 32
2. Press [ ] or [ ] to select the item to be modified [Shape/Transparency/Step/V

Size/H Size]. (For details, please refer to 6.2 Setting Menu.)

3. Press [ ] or [ ] to perform the modification.
4. Press [MENU] to exit the image OSD menu and return to Spotlight mode.

7.18 I would like to play the slides (Slide Show)

7.18.1 Setting delay time

1. Press [MENU] on the remote control or control panel to enter the setting menu.
2. Press [ ], [ ], [ ], or [ ] to select [Setting].
3. Press [ENTER] key to enter.
4. Press [ ] or [ ] to the [Storage] menu.
5. Press [ ] to find [Delay].
6. Press [ ] or [ ] to select image switch mode between [0.5 Sec/1 Sec/3 Sec/5 Sec/10 Sec/Manual].
7. Press [MENU] to exit.

7.18.2 Activating/Pausing/Stopping the slide show

<Note> Upper Limit: The maximum size of single photo is 7 MB. If you use the remote control or the control panel

1. Press [MENU] to enter the setting menu.
2. Press [ ], [ ], [ ], or [ ] to select [Slide Show].
3. Press [ENTER] to play.
4. Press [ENTER] again to Pause/Play.
5. Press [MENU] to exit.
Page 33 of the Lumens Technology PC170 user manual — 7.20 I would like to reduce the image noise (Projector Type)
Page 33 · click to enlarge
Page 33

7.19 I would like to compare images (compare live images with stored images (PIP))

This function will compare and contrast a live image with a stored image.

Lumens Technology PC170 — 7.14 I would like to delete the captured/recorded images diagram (page 33)
Fig. 23 · 7.14 I would like to delete the captured/recorded im…

C10 C11 C12

Stored image Live image

Remote control:

1. Press [Playback] to enter the Playback image thumbnails.
2. Press [ ], [ ], [ ], or [ ] to select the file to be compared.
3. Press [PIP] to activate image comparison.
4. Press [ ], [ ], [ ], or [ ] to move the live image.
5. Repeat Steps 1 - 3 to change other image files.
6. Press [MENU] to exit.

7.20 I would like to reduce the image noise (Projector Type)

1. This function enables Document Camera to automatically clear image noise.

The noise is especially obvious when Document Camera is connected to a

DLP projector. You can set the DLP projector to improve the image quality.

2. If there is special noise when VGA out is connected, please set DLP option to

improve the image quality.

Lumens Technology PC170 — 7.20 I would like to reduce the image noise (Projector Type) diagram (page 33)
Fig. 24 · 7.20 I would like to reduce the image noise (Project…
Lumens Technology PC170 — 7.20 I would like to reduce the image noise (Projector Type) diagram (page 33)
Fig. 25 · 7.20 I would like to reduce the image noise (Project…

2.1. Press [MENU] on the remote control or control panel to enter the setting

menu.

Page 34 of the Lumens Technology PC170 user manual — 7.22 I would like to change the splash screen
Page 34 · click to enlarge
Page 34

2.2. Press [], [], [], or [] to select [Setting].

2.3. Press [ENTER] key to enter.

2.4. Press [] or [] to select [Control].

2.5. Press [] to enter [Projector Type].

2.6. Press [] or [] to select [LCD/DLP].

2.7. Press [MENU] to exit.

7.21 I would like to resume the factory default settings (Factory Reset) 7.21.1 Using OSD menu

1. Press [MENU] on the remote control or control panel to enter the setting

menu.

2. Press [ ], [ ], [ ], or [ ] to select [Setting].
3. Press [ENTER] key to enter.
4. Press [ ] or [ ] to select [Advanced] menu.
5. Press [ ] to select [Factory Reset].
6. Press [ ] or [ ] to select [Yes].
7. Press [ENTER] to activate.

7.21.2 Use Compound Key

1. Use the Control panel , and press [ENTER] + [MENU] simultaneously to

restore the initial value.

<Note> Before using the compound keys, please remove all VGA-IN devices.

7.22 I would like to change the splash screen

<Note> The splash file must be less than 5 MB and in JPEG format.

1. Press [Menu] on the remote control or control panel to enter the setting

menu.

2. Press [ ], [ ], [ ], or [ ] to select [Setting].
3. Press [ENTER] key to enter.
4. Press [ ] or [ ] to select [Advanced] menu.
5. Press [ ] to select [Splash Screen Settings].
6. Press [ENTER] key to enter.
7. Press [ ] or [ ] to enter the [Power On Image Setting] menu and press [ ]

or [] to select [Default/Custom].

8. Press [ ] or [ ] to enter the [Power On Logo Show time] menu and press
Page 35 of the Lumens Technology PC170 user manual — 7.24.1 I would like to insert a photo in MS-Paint
Page 35 · click to enlarge
Page 35

[] or [] to set up display time span.

9. Skip to Step 12 if your select [Default] in Step 7.
10. Press [ ] or [ ] to enter the [Power On Image Select] menu and press

[ENTER] to read selected file.

11. Select [YES] to confirm the modification.
12. Press [ ] to display the [Exit] dialog box and press [ENTER] key to exit.

7.23 I would like to use a SD card

1. After the SD card is inserted, the [Copy To SD Card] dialog box will be

displayed for you to select to copy files in PC170 to SD card.

Press [] or [] on the remote control or control panel to

select.

7.24 Computer-related functions

Ensure that the USB cable is connected and the drivers are installed before using

the computer-related functions. Refer to Chapter 4 Installation and Connections

in this User Manual.

7.24.1 I would like to insert a photo in MS-Paint

1. Click [File/From Scanner or Camera] in MS-Paint as shown in the bottom left

figure.

Lumens Technology PC170 — 7.24.1 I would like to insert a photo in MS-Paint diagram (page 35)
Fig. 26 · 7.24.1 I would like to insert a photo in MS-Paint
Lumens Technology PC170 — 7.24.1 I would like to insert a photo in MS-Paint diagram (page 35)
Fig. 27 · 7.24.1 I would like to insert a photo in MS-Paint

Copy To SD · Yes No

Page 36 of the Lumens Technology PC170 user manual — 7.24.3 I would like to set the PC170 as a PC Camera
Page 36 · click to enlarge
Page 36
2. Click [Get Picture] will capture the photos of live images and insert the files in

use shown as top right figure.

<Remark> Support Windows XP Operation System only.

7.24.2 I would like to insert images in Photoshop

1. Click [File/Import/WIA Support] in Photoshop .
Lumens Technology PC170 — 7.24.2 I would like to insert images in Photoshop diagram (page 36)
Fig. 28 · 7.24.2 I would like to insert images in Photoshop
2. Complete by clicking [Capture], then clicking [Get Picture].

7.24.3 I would like to set the PC170 as a PC Camera

<Remark> For Windows XP, please set by system name (USB video device)

Open [My Computer] and click [Lumens Document Camera] to open a live image.

Page 37 of the Lumens Technology PC170 user manual — 7.14 I would like to delete the captured/recorded images
Page 37 · click to enlarge
Page 37
Lumens Technology PC170 — 7.14 I would like to delete the captured/recorded images diagram (page 37)
Fig. 29 · 7.14 I would like to delete the captured/recorded im…

Lumens Document

Page 38 of the Lumens Technology PC170 user manual — Chapter 8 Connecting to Microscope
Page 38 · click to enlarge
Page 38

Chapter 8 Connecting to Microscope

1 Mount the microscope adapter onto the microscope.

<Note> The Microscope adapter accessories are applicable to eyepieces of about

Ø 28.4mm.

2 Connect the lens of PC170 with the microscope adaptor

Lumens Technology PC170 — Chapter 8 Connecting to Microscope diagram (page 38)
Fig. 30 · Chapter 8 Connecting to Microscope

3 Select the [Microscope] mode 3.1. When using the control panel or remote control 3.1.1. Press [MENU] to enter the setting menu. 3.1.2. Press [], [], [], or [] to select [Image mode]. 3.1.3. Press [] or [] to the [Microscope]. 3.1.4. Press [MENU] to exit. 4 If the image is not clear 4.1. Please adjust the focus of microscope. 4.2. Please press the [FOCUS] button on either side of the PC170 lens to activate the auto focus. 5 Digital Zoom 5.1. Press [MENU] to enter the setting menu. 5.2. Press [], [], [], or [] to select [Setting]. 5.3. Press [] or [] to the [Control]. 5.4. Press [] to select [Digital Zoom]. 5.5. Press [] or [] to the [On]. 5.6. Press [MENU] to exit.

Page 39 of the Lumens Technology PC170 user manual — 9.1.3 WXGA output
Page 39 · click to enlarge
Page 39

Chapter 9 DIP Switch Settings

<Note> You should unplug and reconnect the power cord, and then restart the PC170 for all DIP Switch Settings to take effect. 9.1 Connecting to a projector or monitor

9.1.1 XGA output (default values):

Lumens Technology PC170 — 9.1.1 XGA output (default values): diagram (page 39)
Fig. 31 · 9.1.1 XGA output (default values):

9.1.2 SXGA output

Lumens Technology PC170 — 9.1.2 SXGA output diagram (page 39)
Fig. 32 · 9.1.2 SXGA output

9.1.3 WXGA output

Lumens Technology PC170 — 9.1.3 WXGA output diagram (page 39)
Fig. 33 · 9.1.3 WXGA output
Page 40 of the Lumens Technology PC170 user manual — 9.2 Connecting to a TV
Page 40 · click to enlarge
Page 40

9.1.4 1080P output

Lumens Technology PC170 — 9.1.4 1080P output diagram (page 40)
Fig. 34 · 9.1.4 1080P output

9.2 Connecting to a TV

9.2.1 NTSC: USA, Taiwan, Panama, Philippines, Canada, Chile, Japan, Korea, and Mexico.

Lumens Technology PC170 — 9.2 Connecting to a TV diagram (page 40)
Fig. 35 · 9.2 Connecting to a TV

9.2.2 PAL: Countries/regions not listed above.

Lumens Technology PC170 — 9.2 Connecting to a TV diagram (page 40)
Fig. 36 · 9.2 Connecting to a TV

<Remark> Once C-VIDEO is on, VGA OUT is not supported.

Page 41 of the Lumens Technology PC170 user manual — Chapter 10 Troubleshooting
Page 41 · click to enlarge
Page 41

Chapter 10 Troubleshooting

This chapter describes problems you may encounter while using PC170. If you have questions, please refer to related chapters and follow all the suggested solutions. If the problem still occurred, please contact our distributors or service center. No. Problems Solutions 1 Boot without power signal

Make sure you have plugged in the power cord.

2 There is no image output from PC170

1. Check the power. 2. Check all cable connections. Refer to Chapter 4 Installation and Connections in this manual. 3. Check the [Source], refer to 7.2 I would like to switch image sources of Chapter 7 Descriptions of major functions. 4. Check the settings for the source of the projector. For the appropriate input selection of the projector, refer to the projectors user manual. 5. Check if DIP Switch is properly set. Refer to Chapter 9 DIP Switch Settings for related settings. 3 Unable to focus Probably the document is too close. Press [ZOOM -] on the remote control or control panel. Or pull away the lens from the document to increase the distance, and then press the [FOCUS] button on the right side of the lens. 4 The image is incomplete

Check the Auto Image setting of your projector. Please refer to the user manual of the projector or check for the DIP SWITCH settings. 5 Lumens Document Camera, Podium View™ and other applications cannot be used simultaneously

Lumens Document Camera, Podium View™ and other applications cannot be executed simultaneously. Only one application can be executed at a time. Please close the currently running applications and then execute the application to be used.

6 When the unit is turned on, the auxiliary floodlight do not light

Please make sure the arm lamp is set to “OFF”. For the switch-on or -off of arm lamp, please refer to 7.8 I would like to turn on/off the lamp of Chapter 7 Descriptions of major functions. 7 PC170 fails to store images or react

1. Check to see if the stored data have reached the maximum size of the USB device (priority) or internal memory. 2. Please make sure if the Capture function is set to Continuous mode or the time for capture is set to be long. For the related setting, refer to 7.11 I would like
Page 42 of the Lumens Technology PC170 user manual — 7.14 I would like to delete the captured/recorded images
Page 42 · click to enlarge
Page 42

to capture images of Chapter 7 Descriptions of major functions. 8 The images outputted from PC170 are too bright, dark or vague

Press [AUTO TUNE] to automatically adjust to the optimal brightness and focal length.

9 Unable to record images

1 Check to see if the stored data have reached the maximum size of the SD Card. 2 The recording to internal memory is not supported. Please make sure a SD card is inserted prior to video recording. 10 The operating steps in the manual are not applicable to the machine

The operating steps in the manual may be not applicable to the machine due to improvement in functions. Check to see if the Firmware version of your machine is up-to-date. 3 Please go to Lumens official website to check whether the latest version is available for update. www.Mylumens.com/goto.htm 4 The steps to check the FW version are as below: 4.1 Press [MENU] on the remote control or control panel to enter the setting menu. 4.2 Press [], [], [], or [] to select [Setting]. 4.3 Press [ENTER] key to enter. 4.4 Press [] or [] to select [Advanced] menu. 4.5 View [Firmware Version]. If you are not sure whether it is the latest version, please consult your distributor for advice. http://www.Mylumens.com/en/Request_form.php 11 How to unlock the locked device

1. Press [Menu] on the remote control or control panel to enter the setting menu. 2. Press [ ], [ ], [ ], or [ ] to select [Setting]. 3. Press [ENTER] key to enter. 4. Press [ ] or [ ] to select [Advanced] menu. 5. Press [ ] to [Lock Down]. 6. Press [ ] or [ ] to select [Off] and deactivate the password setting function.
Sources

References & links

Pages referenced in this manual — manufacturer, support and downloads.

Ask about the Lumens Technology PC170

Owners and our team usually reply within a day — and your question helps the next person too.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
No questions yet about the Lumens Technology PC170

Be the first to ask — other owners or our team will answer.

Original document

Lumens Technology PC170 manual PDF

42 pages·1.7 MB·Camera Accessories·PDF
Click any page above to open it here
Page 1 / …
100%
Loading pages…