EN
Official user manual

LST Smoke Detector (245402)

1 pages·132 KB·Smoke detector·PDF·ENDEFRITNLJA
LST Smoke Detector (245402)
Table of Contents 5 sections Manual Call Point · HFM/3/32/02 · Description · Specifi cations · … ShowHide
Page 1 of the LST Smoke Detector (245402) user manual — 0786–CPD–20356
Page 1 · click to enlarge
Page 1
LST Smoke Detector (245402) — Manual Call Point diagram (page 1)
Fig. 1 · Manual Call Point

Manual Call Point

LST Smoke Detector (245402) — Manual Call Point diagram (page 1)
Fig. 2 · Manual Call Point
LST Smoke Detector (245402) — Manual Call Point diagram (page 1)
Fig. 3 · Manual Call Point
LST Smoke Detector (245402) — Manual Call Point diagram (page 1)
Fig. 4 · Manual Call Point

HFM/3/32/02

LST Smoke Detector (245402) — HFM/3/32/02 diagram (page 1)
Fig. 5
  • ADM loop technology with Apollo/Discovery protocol
  • Robust die-cast aluminium case
  • LED indicates activation
  • Integrated dual-isolator
  • Operating instructions by means of standardised symbols
  • Increase of protection class to IP54 by using optional protection kit
LST Smoke Detector (245402) — HFM/3/32/02 diagram (page 1)
Fig. 6

Description

The manual call point according to EN 54-11/B is desi- gned for use in ADM loops with Apollo/Discovery proto- col and is accommodated in a robust die-cast aluminium case. In comparison with plastic cases, the aluminium case proves to be of advantage even after years of use, thanks to its resistance to environmental impact: It is virtually unbreakable, form stable and hardly changes its colour in sunlight.

is displayed by an LED. The detector is provided with a dual-isolator, which disconnects the adjacent loop ele- ments fast and safely in case of a short circuit.

The hinged door can be opened up to an angle of 180° and it is provided with a replaceable pane of glass. If the detector has been activated, an integrated locking device prevents the closing of the door. Custom versions with different colours, designs, func- tions and internal wirings are available on inquiry. By means of the optional Protection Kit HFM/HM-ZS-IP54, the protection class can be increased to IP54.

A built-in LED optically indicates the activated condition of the manual call point. The detector address can be set by means of a push-button and the entered address

LST Smoke Detector (245402) — Description diagram (page 1)
Fig. 7 · Description

Specifi cations

Operating voltage Supply through loop voltage

Current consumption 180µA (quiescent)

Ambient temperature -20°C to +60°C

Dimensions W × H × D 125 × 125 × 33 (mm)

Colour fl ame red, RAL 3000

Approval VdS G204003 0786-CPD-20356

Order name Manual Call Point/EN 54/Red/Anal./Apo HFM/3/32/02

0786–CPD–20356

HFM-XP95_DBL_LST_EN_0819.PDF • PAGE 1 A Building Safety. Building Security.

  • © LABOR STRAUSS SICHERUNGSANLAGENBAU GMBH
  • A-1231 WIEN
  • WIEGELESTRASSE 36
  • TEL +43 1 52114-0
  • FAX +43 1 52114-27 [email protected]
  • <a href="http://WWW.LST.AT" rel="nofollow noopener" target="_blank">WWW.LST.AT</a>
  • ALL RIGHTS RESERVED

Protection class IP43 · Weight 400g · Order number 245402

Sources

References & links

Pages referenced in this manual — manufacturer, support and downloads.

Ask about the LST Smoke Detector (245402)

Owners and our team usually reply within a day — and your question helps the next person too.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
No questions yet about the LST Smoke Detector (245402)

Be the first to ask — other owners or our team will answer.

Original document

LST Smoke Detector (245402) manual PDF

1 pages·132 KB·Smoke detector·PDF
Click any page above to open it here
Page 1 / …
100%
Loading pages…