NOTICE The manufacturer of the Industrial Computer makes no representations or warranties, either expressed or implied, by or with respect to anything in this manual, and shall not be liable for any implied warranties of fitness for a particular purpose or for any indirect, special or consequential damages. Information in this document is subject to change without notice and does not represent a commitment on the part of the manufacturer.
FCC NOTICE This device complies with Part 15 of FCC Rules. Operations are subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
LOGIC CONTROLS, INC.
355 Denton Ave New Hyde Park, NY 11040

1. Follow all warnings and instructions marked on the product. 2. Unplug this product from the wall outlet before cleaning. Do not use liquid cleaners or aerosol cleaners. Use a damp cloth for cleaning. 3. Do not use this product near water. 4. This product should be operated from the type of power indicated on the power adaptor. If you are not sure of the type of power available, consult your dealer or local power company. 5. Do not allow anything to rest on the power cord. Do not locate this product where persons will walk on the cord. 6. If an extension cord is used with this product, make sure that the total ampere rating of the equipment plugged into the extension cord does not exceed the extension cord ampere rating. Also, make sure that the total rating of all products plugged into the wall outlet does not exceed the fuse rating. 7. Allow at least 6 inches of space from the top of the unit and 3 inches from the sides to allow proper ventilation. 8. We recommend all servicing done on this product be done by qualified service personnel. Aside from upgrades or swapping out the compact flash or hard-drive please refer all other servicing to the Logic Controls RMA Dept. 9. Unplug this product from the wall outlet and refer servicing to qualified service personnel under the following conditions:
a) When the power cord or plug is damaged or frayed b) If liquid has been spilled into the product c) If the product has been exposed to rain or water d) If the product does not operate normally when the operating instructions are
followed. Adjust only those controls that are covered by the operating instructions since improper adjustment of other controls may result in damage and will often require extensive work by a qualified technician to restore the product to normal condition. e) If the product has been dropped or the cabinet has been damaged f) If the product exhibits a distinct change in performance, indicating a need for
service.



OVERVIEW The Logic Controls LC8000 provides unparalleled reliability by being a fanless unit with no moving mechanical parts. It is an ideal computer for use in harsh environments with high levels of dust or oil when fan noise is not desirable. For mass storage, compact flash memory provides true no-moving-part operation. In addition, all components and connectors reside on one PC board, thus no internal cables (sources of common loose connections) are required. The computer is housed in a rugged die cast case for extra protection. The LC8000 has a very compact form factor - only 2”H x 8”W x 6”L. Two mounting brackets enable these units to be mounted almost anywhere – on a wall, ceiling, table top or under a counter. The LC-8000 uses Intel-compatible, Pentium-class processors, so it can run Windows and Linux-based applications. Whether your application runs on Windows XP, Windows XP embedded, Windows 2000, Windows CE or any flavor of Linux, your operating system needs are supported by the LC8000. This enables the unit to be used in a wide variety of applications – in a restaurant’s kitchen system, in a POS workstation, in an auto ID workstation, etc. The LC8000 also provides a very impressive compliment of up-to-date I/O ports – Ethernet, parallel, PS/2 and multiple USB 2.0, RS232, and SVGA ports are all included.


As it’s a fan-less computer, adequate ventilation is required to ensure normal operation. Allow at least 6 inches of space from the top of the unit and 3 inches from the sides to allow proper ventilation.

} Optional Equipment


TROUBLESHOOTING If you encounter a hardware problem, we recommend that you review the following suggestions before calling for service: General failure

AMIBIOS NEW SETUP UTILITY – VERSION 3.31a
Advanced BIOS Features [ Setup Help ]
Quick Boot Enabled Boot Device Priority 1st Disabled 2nd Disabled 3rd Disabled
Try Other Boot Devices Yes USB Controller 4 USB Ports USB 1.1 Device Legacy Support Disabled Initial Display Mode BIOS Display Mode at Add-On ROM Init Force BIOS S.M.A.R.T. for Hard Disks Disabled BootUp Num-Lock On PS/2 Mouse Support Enabled Primary Display VGA/EGA Password Check Setup Ask HDD Password on Every Boot Yes
Wait for ‘F1’ If Error Enabled
CPU MicroCode Updation Enabled
CPU Serial Number Disabled System BIOS Cacheable Enabled C000,32K Shadow Cached C800,16K Shadow Disabled CC00,16K Shadow Disabled D000,16K Shadow Disabled D400,16K Shadow Disabled D800,16K Shadow Disabled DC00,16K Shadow Disabled