The RAT1 is an infrared remote controlled stereo speaker volume control with impedance matching capability. It allows individual volume control of from one to 16 pair of stereo speakers from one stereo power amplifier, using one RAT1 for each stereo speaker pair. It is controlled with any Xantech IR Receiver or keypad or with Xantech MIRV1 motorized volume controls. The RAT1 maintains correct imped- ance matching between the amplifier and the speak- ers with the use of instant setting S1 to S8 jumpers, located on the unit. This eliminates the need for separate impedance matching devices in multi-room installations.

Fig. 1 The RAT1
FEATURES AND SPECIFICATIONS • 10-position relay driven stepped auto transformer design.

RC68 PROGRAMMER / REMOTE CONTROL The RC68+ (and the RC68) programmer (available separately) contains all the commands necessary to operate the RAT1.
1. IR Emitter Lens
The relationship of the RC68 buttons to the RAT1 volume step positions is as follows:
A
A, B, C 1 (OFF, MIN. VOL)
80 48 10 90 01
1 2 3 4
ADJ-OFF 2
40 A0 30 B0 21
5 6 7 8
20 E0 70 F0 61
Z-ADJ TREBLE VOL
BASS
60 88 18 98 09
MUTE
ON OFF
28 E8 78 F8 69
E-FLAT LAST MAX-V TRIM
OFF C-BAL
68 C8 58 D8 49
E1 89 C9 A9 E9
71 19 59 39 79
Fig. 2 The RC68+
8 10 (MAX VOL)
RC68+ PROGRAMMER
Programmer

SETTING THE IMPEDANCE MATCHING JUMPERS The impedance matching jumpers are located under a clear mylar cover on the right side of the top of the unit. Remove the two screws for access. The proper placement of these jumpers depends on the number of RAT1's and speakers used in the total installation. To set them for the best impedance matching condition, refer to the following charts and procedures:
13 pairs of 8 Ohm wall speakers are to be used with 13 RAT1's in a 13 room system, all driven by one amplifier rated for 4 Ohms minimum safe operating load impedance.
3 pairs of 4 Ohm wall speakers are to be used with 3 RAT1's in a 3 room system, all driven by one amplifier rated for 8 Ohms minimum safe operating load impedance.

In this case, treat all speakers that are rated between 4 and 7 Ohms as 4 Ohm speakers, and use the charts accordingly. Similiarly, all speakers that are rated 8 Ohms or higher, treat as 8 Ohms speakers. Again, all speakers used in the system should be the same impedance (i.e. all 6 Ohms, all 7 Ohms, etc.).
As a rule of thumb, use good quality 18 gauge speaker wire for runs up to 30', 16 gauge up to 70', and 14 gauge up to 150'. The 4-terminal connectors accept wire sizes up to 12 gauge max.
You may run into installations where you need to combine speakers of different impedance in the same system (8, 6, 4 Ohms, etc.). This is a more complicated situation that requires some calculation to obtain optimum results. You need to find the paralleled impedance for each group of speakers with the same impedance first and pick an "S" setting for each. Then check the overall paralleled "S" settings to see that the impedance is higher than the minimum safe value specified for the amplifier.
2 pairs of 4 Ohm and 7 pairs of 8 Ohm wall speakers are to be used with 9 RAT1's in a 9 room system, all driven by one amplifier rated for 4 Ohms minimum safe operating load impedance.
4 ÷ 2 = 2 Ohms.
8 ÷ 7 = 1.14 Ohms.
ZO = 1 ÷ [(1÷Z1) + (1÷Z2) + (1÷ZN...etc.)]
Z 1 = 1st paralleled group after S setting
Z 2 = 2nd paralleled group after S setting
Z N = additional paralleled groups, when used
Since only two paralleled groups are used in this example, the calculation is as follows:
ZO = 1 ÷ [(1÷8) + (1÷9.12)] = 4.26 Ohms.
Since this yields more than 4 Ohms, the S4 setting for the 4 Ohm group and the S8 setting for the 8 Ohm group are the correct ones to use.
2 pairs of 4 Ohm, 3 pairs of 6 Ohm and 7 pairs of 8 Ohm wall speakers are to be used with 12 RAT1's in a 12 room system, all driven by one amplifier rated for 4 Ohms minimum safe operating load impedance.
4 ÷ 2 = 2 Ohms.
6 ÷ 3 = 2 Ohms.
8 ÷ 7 = 1.14 Ohms.

ZO = 1 ÷ [(1÷16) + (1÷16) + (1÷9.12)] = 4.26 Ohms.
Since this yields more than 4 Ohms, the S8 setting for the 4 Ohm group, the S8 setting for the 6 Ohm group and the S8 setting for the 8 Ohm group are the correct ones to use.
INSTALLATION – COMMON IR BUS SYSTEM Fig. 3 illustrates a typical installation using three RAT1's along with other Xantech products in a 4-room multi-room system. The principles shown should be used as a guide when planning your own specific installations. It is configured as follows:
To make code group changes, refer to the RC68+ Programmer Instructions.

If you wish to carry remotes that have the same codes from room-to-room, use a Dedicated IR Bus System as shown in Fig. 4.
IR IN (IR), STATUS (ST), GND (G) and +12VDC (V).
Up to 3 RAT1's plus associated MIRV1's and IR components can be used with one 782-00 Power Supply. (e.g. 9 RAT1's with associated components would require 3 of the 782-00 Power Supplies). Typical power supply connections are shown in Figs. 3, 4 and 6.


786-00 "STATUS" power supply. Plug into a SWITCHED AC Outlet on A/V Receiver (see text).
IR Receiver (i.e. cabinet mounted for IR control in main room)
Fig. 3 A RAT1 System Using a Common IR Bus

INSTALLATION – DEDICATED IR BUS SYSTEM Fig. 4 illustrates an installation where each remote room has a Dedicated IR Bus going to the RAT1 that controls it. The IR bus is not connected in common as it is in Fig. 3. This eliminates the need for dedicated remotes, allowing you to carry the same remote(s) from room-to-room. It is configured as follows:
Set the LOGIC POLARITY SELECTOR DIP switches on the 793 for "active high" operation - that is - all even numbered switches to "ON" - all odd numbered switches to "OFF".
For systems using more than five RAT1's, you will need additional 793-00's. These can be easily "daisy chained" as shown in Fig. 5.
If a particular system requires a code group number change, refer to the RC68+ Programmer Instructions for code group setting procedures.
IR IN (IR), STATUS (ST), GND (G) and +12VDC (V).
Fig.5 illustrates how two 793-00 Serial Control Combiners are "Daisy-Chained" to accommodate additional RAT's in a dedicated IR Bus System. This process can be repeated as necessary to accommodate the number of RAT's needed in the system. Simply connect the "B" CONTROL OUTPUTS port of the next 793 into the "A" CONTROL OUTPUTS port on the preceding 793 with a 3.5-to-3.5mm mono-mini cable as shown.


786-00 "STATUS" power supply. Plug into a SWITCHED AC Outlet on A/V Receiver (see text).
L O G I C P O L A R I T Y
1 2 3 4 5 6 7 8 9 1 0
Fig. 4 A RAT1 Dedicated IR Bus System

793-10 Serial Combiner

L O G I C P O L A R I T Y
L O G I C P O L A R I T Y
1 2 3 4 5 6 7 8 9 1 0
1 2 3 4 5 6 7 8 9 1 0
"Daisy-Chain" connection. Use 3.5/3.5mm Mini- Plug cable, Pt. # 6017400
Fig. 5 Daisy-Chaining 793-00's in Multiple RAT1 Dedicated IR Bus Systems
In some cases you may need to drive more than one set of speakers from a single RAT1, such as in large rooms or adjoining areas where common volume operation is acceptable. A typical system is shown in Fig. 6.

Fig. 6 Driving Two Speaker Pairs From One RAT1
12-8-00 Rev.C
INSTALLATION (cont'd)
Owners and our team usually reply within a day — and your question helps the next person too.