Lochinvar CB-045

1 pages·28 KB·Boiler·PDF·EN
Lochinvar CB-045
Table of Contents 1 sections SOLUTION ® BOILER PRODUCT SUMMARY (CB) 45,000 - 260,000 BTU/HR ShowHide
Page 1 of the Lochinvar CB-045 user manual — SOLUTION ® BOILER PRODUCT SUMMARY (CB) 45,000 - 260,000 BTU/HR
Page 1 · click to enlarge
Page 1
Lochinvar CB-045 — SOLUTION ® BOILER PRODUCT SUMMARY (CB) 45,000 - 260,000 BTU/HR diagram (page 1)
Fig. 1

SOLUTION ® BOILER PRODUCT SUMMARY (CB) 45,000 - 260,000 BTU/HR

CB-045CB-075CB-090CB-135CB-180CB-215CB-260 WATER GALLON CAPACITY0.80.80.80.80.90.91.0 HEATING SURFACE (SQ. FT.)5.810.610.615.319.923.526.9 WATER CONNECTIONS1-1/2”1-1/2”1-1/2”1-1/2”1-1/2”1-1/2”1-1/2” DRAIN3/4”3/4”3/4”3/4”3/4”3/4”3/4” MAX. WATER FLOW RATE (GPM)30303030303030 HEAD LOSS (FT. OF HD.)5.15.35.35.75.96.16.3 MIN. WATER FLOW RATE (GPM) *23467911 HEAD LOSS (FT. OF HD.) *0.20.20.20.30.40.40.5 MAX. WORKING PRESSURE (PSI)160160160160160160160 # OF RELIEF VALVES1111111 RELIEF VALVE SIZE3/4”3/4”3/4”3/4”3/4”3/4”3/4” RELIEF VALVE RATING (MBH)510510510510510510510 RELIEF VALVE PRESSURE RATING (PSI)30303030303030 GAS INLET CONNECTION1/2”1/2”1/2”1/2”3/4”3/4”3/4” MAX. INLET PRESSURE, NAT10.5” w.c.10.5” w.c. MIN. INLET PRESSURE, NAT4.5” w.c.4.5” w.c. MANIFOLD PRESSURE, NAT3.5” w.c.2.4” w.c.3.5” w.c. MAX. INLET PRESSURE, LP13.0” w.c.13.0” w.c. MIN. INLET PRESSURE, LP11.0” w.c.11.0” w.c. MANIFOLD PRESSURE, LP10.0” w.c.7.0” w.c.10.0” w.c. BTU/HR INPUT45,00075,00090,000135,000180,000215,000260,000 BTU/HR OUTPUT (HIGH FIRE)36,90061,50073,800110,700147,600176,300213,200 BTU/HR OUTPUT (LOW FIRE)18,45030,75036,90055,35073,80088,150106,600 ELECTRICAL VOLTAGE/HEATER120120120120120120120 VOLTAGE/CONTROL24242424242424 TOTAL AMPS2.02.02.02.02.02.02.0 # OF ELECTRICAL CONNECTIONS1111111 DIMENSIONS HEIGHT29-1/2”29-1/2”29-1/2”29-1/2”29-1/2”29-1/2”29-1/2” WIDTH11-1/2”15-1/2”15-1/2”19-1/2”23-1/2”26-1/2”29-1/2” DEPTH21-1/2”21-1/2”21-1/2”21-1/2”21-1/2”21-1/2”21-1/2” SERVICE CLEARANCES FRONT24”24”24”24”24”24”24” BACK6”6”6”6”6”6”6” RIGHT SIDE6”6”6”6”6”6”6” LEFT SIDE (PIPING)24”24”24”24”24”24”24” TOP14”14”14”14”14”29”29” VENTING SIZE4”5”5”6”7”7”8” VENT CATEGORYIIIIIII VENT MATERIALB-VENTB-VENTB-VENTB-VENTB-VENTB-VENTB-VENT MAXIMUM DRAFT-0.05” w.c.-0.05” w.c. MINIMUM DRAFT-0.02” w.c.-0.02” w.c.

* Minimum flow rate and head loss are based on a 40°F temperature rise for all models.

  • Lochinvar Corporation
  • 300 Maddox Simpson Pkwy
  • Lebanon, TN 37090
  • 615-889-8900 / Fax: 615-547-1000

www.Lochinvar.com

RSB-PS-04 (Replaces RSB-PS-03 01/09) 01/09-Printed in U.S.A.

Sources

References & links

Pages referenced in this manual — manufacturer, support and downloads.

Ask about the Lochinvar CB-045

Owners and our team usually reply within a day — and your question helps the next person too.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
No questions yet about the Lochinvar CB-045

Be the first to ask — other owners or our team will answer.

Original document

Lochinvar CB-045 manual PDF

1 pages·28 KB·Boiler·PDF
Click any page above to open it here
Page 1 / …
100%
Loading pages…