Lochinvar 3.5

56 pages·2.9 MB·Boiler·PDF·ENDEFRITNLJA
Lochinvar 3.5
Table of Contents 80 sections Service Manual Models: 1.5 - 2.0 - 2.5 - 3.0 - 3.5 · WARNING · Contents · Hazard definitions · … ShowHide
Service Manual Models: 1.5 - 2.0 - 2.5 - 3.0 - 3.5p.1 WARNINGp.1Contentsp.2Hazard definitionsp.2 DANGERp.2 CAUTIONp.2CAUTIONp.2NOTICEp.2Please read before proceedingp.3 WARNING NOTICEp.3Handling ceramic fiber materialsp.3REMOVAL OF COMBUSTION CHAMBER LININGp.3When servicing boiler –p.4Boiler operation –p.4Boiler water –p.4Freeze protection fluids –p.4What is in this manual?p.5Maintenancep.5Troubleshootingp.5Boiler pipingp.61 Service (continued)p.7Control inputsp.8Control outputsp.9General Operationp.10Sequence of operationp.121 Service (continued) Parameter tablep.13Parameter tablep.14OUTDOORp.14RESET RAMP DELAY BMSp.14ADVANCED SETUP SH NIGHT SETBACKp.15HWG NIGHT SETBACK CASCADE MODp.16BUSp.16Viewable and changeable control parametersp.18E: BMSp.21Minimum On/Off Timep.23Cascade Offsetp.23Cascade Screenp.26Graph Screenp.27History Screenp.28Service Screenp.302 Maintenancep.31Maintenance and annual startupp.31Service technician (see the following pages for instructions)p.31Owner maintenance (see the Crest User’s Information Manual forp.31General:p.31Dailyp.31Monthlyp.31ANNUAL START-UPp.31Every 6 monthsp.31If combustion or performance indicate need:p.31End of seasonp.31monthsp.31Address reported problemsp.32Inspect boiler areap.32Check all piping for leaksp.32Inspect boiler interiorp.32Clean condensate trapp.322 Maintenance (continued)p.33Flue vent system and air pipingp.33Check water systemp.33Check expansion tankp.33Check boiler relief valvep.33Inspect ignition and flame sense electrodesp.34Check ignition ground wiringp.34Check all boiler wiringp.34Check control settingsp.34Perform start-up and checksp.34Check flame signalp.34Check burner flamep.343 Troubleshootingp.36Check control module fusesp.36Before troubleshooting:p.36Check the following:p.363 Troubleshooting (continued)p.37FAULT CAUSE CORRECTIVE ACTIONp.37Checking temperature sensorsp.38FAULT DESCRIPTION CORRECTIVE ACTIONp.40Combustion Analysis Procedurep.52CO 2 O 2 CO 2 O 2p.52POSSIBLE CAUSE CORRECTIVE ACTIONp.52
Page 1 of the Lochinvar 3.5 user manual —  WARNING
Page 1 · click to enlarge
Page 1
Lochinvar 3.5 — Service Manual Models: 1.5 - 2.0 - 2.5 - 3.0 - 3.5 diagram (page 1)
Fig. 1 · Service Manual Models: 1.5 - 2.0 - 2.5 - 3.0 - 3.5
Lochinvar 3.5 — Service Manual Models: 1.5 - 2.0 - 2.5 - 3.0 - 3.5 diagram (page 1)
Fig. 2 · Service Manual Models: 1.5 - 2.0 - 2.5 - 3.0 - 3.5

Service Manual Models: 1.5 - 2.0 - 2.5 - 3.0 - 3.5

WARNING

This manual must only be used by a qualified heating installer / service technician. Read all instructions, including this manual and the Crest Installation and Operation Manual, before installing. Perform steps in the order given. Failure to comply could result in severe personal injury, death, or substantial property damage.

Save this manual for future reference.

FB-SER Rev B

Page 2 of the Lochinvar 3.5 user manual — Table of Contents
Page 2 · Contents
Contents

Contents

Service Manual Models: 1.5 - 2.0 - 2.5 - 3.0 - 3.5p.1 WARNINGp.1Contentsp.2Hazard definitionsp.2 DANGERp.2 CAUTIONp.2CAUTIONp.2NOTICEp.2Please read before proceedingp.3 WARNING NOTICEp.3Handling ceramic fiber materialsp.3REMOVAL OF COMBUSTION CHAMBER LININGp.3When servicing boiler –p.4Boiler operation –p.4Boiler water –p.4Freeze protection fluids –p.4What is in this manual?p.5Maintenancep.5Troubleshootingp.5Boiler pipingp.61 Service (continued)p.7Control inputsp.8Control outputsp.9General Operationp.10Sequence of operationp.121 Service (continued) Parameter tablep.13Parameter tablep.14OUTDOORp.14RESET RAMP DELAY BMSp.14ADVANCED SETUP SH NIGHT SETBACKp.15HWG NIGHT SETBACK CASCADE MODp.16BUSp.16Viewable and changeable control parametersp.18E: BMSp.21Minimum On/Off Timep.23Cascade Offsetp.23Cascade Screenp.26Graph Screenp.27History Screenp.28Service Screenp.302 Maintenancep.31Maintenance and annual startupp.31Service technician (see the following pages for instructions)p.31Owner maintenance (see the Crest User’s Information Manual forp.31General:p.31Dailyp.31Monthlyp.31ANNUAL START-UPp.31Every 6 monthsp.31If combustion or performance indicate need:p.31End of seasonp.31monthsp.31Address reported problemsp.32Inspect boiler areap.32Check all piping for leaksp.32Inspect boiler interiorp.32Clean condensate trapp.322 Maintenance (continued)p.33Flue vent system and air pipingp.33Check water systemp.33Check expansion tankp.33Check boiler relief valvep.33Inspect ignition and flame sense electrodesp.34Check ignition ground wiringp.34Check all boiler wiringp.34Check control settingsp.34Perform start-up and checksp.34Check flame signalp.34Check burner flamep.343 Troubleshootingp.36Check control module fusesp.36Before troubleshooting:p.36Check the following:p.363 Troubleshooting (continued)p.37FAULT CAUSE CORRECTIVE ACTIONp.37Checking temperature sensorsp.38FAULT DESCRIPTION CORRECTIVE ACTIONp.40Combustion Analysis Procedurep.52CO 2 O 2 CO 2 O 2p.52POSSIBLE CAUSE CORRECTIVE ACTIONp.52
Page 3 of the Lochinvar 3.5 user manual —  WARNING
Page 3 · click to enlarge
Page 3

Please read before proceeding

WARNING NOTICE

Installer – Read all instructions, including this manual and the Crest Installation and Operation Manual, before installing. Perform steps in the order given.

When calling or writing about the boiler – Please have the boiler model and serial number from the boiler rating plate.

Consider piping and installation when determining boiler location (see the Crest Installation and Operation Manual).

User – This manual is for use only by a qualified heating installer/service technician. Refer to the Crest User’s Information Manual for your reference.

Any claims for damage or shortage in shipment must be filed immediately against the transportation company by the consignee.

Have this boiler serviced/inspected by a qualified service technician at least annually.

Failure to comply with the above could result in severe personal injury, death or substantial property damage.

Handling ceramic fiber materials

REMOVAL OF COMBUSTION CHAMBER LINING

The combustion chamber insulation in this appliance contains ceramic fiber material. Ceramic fibers can be converted to cristobalite in very high temperature applications. The International Agency for Research on Cancer (IARC) has concluded, “Crystalline silica in the form of quartz or cristobalite from occupational sources is carcinogenic to humans (Group 1).” Normal operating temperatures in this appliance are below the level to convert ceramic fibers to cristobalite. Abnormal operating conditions would have to be created to convert the ceramic fibers in this appliance to cristobalite.

WARNING

The ceramic fiber material used in this appliance is an irritant; when handling or replacing the ceramic materials it is advisable that the installer follow these safety guidelines.

Avoid breathing dust and contact with skin and eyes. • Use NIOSH certified dust respirator (N95). This type of respirator is based on the OSHA requirements for cristobalite at the time this document was written. Other types of respirators may be needed depending on the job site conditions. Current NIOSH recommendations can be found on the NIOSH website at http://www.cdc.gov/niosh/homepage.html NIOSH approved respirators, manufacturers, and phone numbers are also listed on this website.

  • Wear long-sleeved, loose fitting clothing, gloves, and eye protection.

Apply enough water to the combustion chamber lining to prevent airborne dust.

Remove the combustion chamber lining from the appliance and place it in a plastic bag for disposal.

Wash potentially contaminated clothes separately from other clothing. Rinse clothes washer

thoroughly.

NIOSH stated First Aid.

Eye: Irrigate immediately. Breathing: Fresh air.

Page 4 of the Lochinvar 3.5 user manual — Freeze protection fluids –
Page 4 · click to enlarge
Page 4

Please read before proceeding

When servicing boiler –

  • To avoid electric shock, disconnect electrical supply before performing maintenance.
  • To avoid severe burns, allow boiler to cool before performing maintenance.

Boiler operation –

  • Do not block flow of combustion or ventilation air to the boiler.
  • Should overheating occur or gas supply fail to shut off, do not turn off or disconnect electrical supply to circulator. Instead, shut off the gas supply at a location external to the appliance.
  • Do not use this boiler if any part has been under water. The possible damage to a flooded appliance can be extensive and present numerous safety hazards. Any appliance that has been under water must be replaced.

Boiler water –

  • Thoroughly flush the system (without boiler connected) to remove sediment. The high-efficiency heat exchanger can be damaged by build-up or corrosion due to sediment.
  • Do not use petroleum-based cleaning or sealing compounds in the boiler system. Gaskets and seals in the system may be damaged. This can result in substantial property damage.
  • Do not use “homemade cures” or “boiler patent medicines”. Serious damage to the boiler, personnel, and/or property may result.
  • Continual fresh make-up water will reduce boiler life. Mineral buildup in the heat exchanger reduces heat transfer, overheats the stainless steel heat exchanger, and causes failure. Addition of oxygen carried in by makeup water can cause internal corrosion. Leaks in boiler piping must be repaired at once to prevent the introduction of makeup water.

Freeze protection fluids –

  • NEVER use automotive antifreeze. Use only inhibited propylene glycol solutions which are specifically formulated for hydronic systems. Ethylene glycol is toxic and can attack gaskets and seals used in hydronic systems.
Page 5 of the Lochinvar 3.5 user manual — Troubleshooting
Page 5 · click to enlarge
Page 5

What is in this manual?

Maintenance

Near boiler piping • Typical system components

  • Service and maintenance schedules
  • Address reported problems
  • Inspect boiler area and boiler interior
  • Clean condensate trap
  • Check all piping for leaks
  • Check air openings
  • Flue vent system and air piping
  • Check water system
  • Check expansion tank
  • Check boiler relief valve
  • Inspect ignition electrode
  • Check ignition ground wiring
  • Check all boiler wiring
  • Check control settings
  • Perform start-up and checks
  • Check burner flame
  • Check flame signal
  • Check flue gas temperature
  • General maintenance
  • Review with owner
  • Cleaning boiler heat exchanger
  • Oiled bearing circulators

The Crest boiler display • Display panel readout, buttons and their functions

Control module inputs • Control module inputs and options

Control module outputs • Control module outputs and options

  • General
  • How the boiler operates
  • How the control module operates
  • Access modes -- user and installer
  • Sequence of operation -- HWG/space heating

Control panel menu access • Accessing programming mode and locating menus (See separate guide covering the PC interface.)

Control panel parameter access • Accessing and changing parameters from the display panel

Troubleshooting

  • Troubleshooting table - No display
  • Checking temperature sensors
  • Sensor tables
  • Troubleshooting table - Fault messages displayed on boiler interface
  • Combustion analysis procedure
  • Gas valve adjustment procedure

Quick start information -- parameter table • An index of available adjustments and readouts, where to access them and where to find detailed information.

  • Crest boiler operation
  • Initial Setup
  • Set Points
  • Outdoor Reset
  • Ramp Delay
  • BMS
  • Advanced Setup
  • SH Night Setback
  • HWG Night Setback
  • Cascade
  • Pumps
  • Service Notification
Page 6 of the Lochinvar 3.5 user manual — Boiler piping
Page 6 · click to enlarge
Page 6

Boiler piping

This piping reference is included to specify the Boiler Piping specific to the Crest boiler. This piping scheme is important for proper operation of the SMART TOUCH control. See the Crest Installation and Operation Manual for more detailed piping diagrams.

Single Boiler - Recommended - Primary / Secondary Piping with a Hot Water Generator

Lochinvar 3.5 — Boiler piping diagram (page 6)
Fig. 3 · Boiler piping

Single Boiler - Alternate - Full Flow System Piping

Lochinvar 3.5 — Boiler piping diagram (page 6)
Fig. 4 · Boiler piping
Page 7 of the Lochinvar 3.5 user manual — 1 Service (continued)
Page 7 · click to enlarge
Page 7

1 Service (continued)

The Home Screen displays status, modulation rate, outlet water temperature, inlet water temperature, flue temperature, system supply temperature, system return temperature, outdoor air temperature, and domestic hot water tank temperature.

The boiler can be started and stopped by pressing the ON/OFF button. The Boiler Status Screen and Main Menu Screen can be accessed by pressing the appropriate button.

Lochinvar 3.5 — 1 Service (continued) diagram (page 7)
Fig. 5 · 1 Service (continued)

When the ON/OFF switch is turned to the ON position, the first screen visible on the LCD display will be the Home Screen. This screen displays the current status of the Crest boiler. The following items can be viewed or interacted with on the Home Screen:

HWG Temperature - This is the temperature as measured by the tank sensor in the hot water storage tank (if connected).

Flue Temperature - Temperature measured by the flue sensor.

Time - The time is displayed in the lower left-hand corner of the display. Reference this manual for Night Setback parameters and more information regarding adjusting the date and time.

On/Off button - Pressing this button allows the boiler to be placed in either Manual Shutdown Mode or Standby Mode.

Boiler Status button - Pressing this button brings up the Boiler Status Screen. This screen shows the status of the various safeties, inputs, and outputs to the control module. Reference this manual for more information regarding this screen.

Status - This line shows the current operating status of the Crest boiler and the current set point.

Outlet Water Temperature - This is the boiler outlet temperature.

Main Menu button - Pressing this button brings up the Main Menu Screen. From this screen navigation to nine (9) other screens is possible.

Inlet Water Temperature - This is the boiler inlet temperature.

System Supply Temperature - This is the water temperature as measured by the system supply sensor located in the downstream piping (if connected).

Modulation button - Pressing this button brings up the Modulation Screen. This screen shows overall boiler modulation, individual fan speeds, and flame currents.

System Return Temperature - This is the water temperature measured by the system return sensor located in the upstream piping (if connected).

Modulation Percentage - Displays the current boiler firing rate.

Outside Air Temperature - This is the outdoor air temperature (if connected).

Home Screen

Page 8 of the Lochinvar 3.5 user manual — Control inputs
Page 8 · click to enlarge
Page 8

Control inputs

Lochinvar 3.5 — Control inputs diagram (page 8)
Fig. 6 · Control inputs
Page 9 of the Lochinvar 3.5 user manual — Control outputs
Page 9 · click to enlarge
Page 9

1 Service (continued)

Control outputs

Lochinvar 3.5 — Control outputs diagram (page 9)
Fig. 7 · Control outputs
Page 10 of the Lochinvar 3.5 user manual — General Operation
Page 10 · click to enlarge
Page 10

General Operation

Figure 1-1 Home Screen

How the boiler operates

Lochinvar 3.5 — General Operation diagram (page 10)
Fig. 8 · General Operation

The Crest uses an advanced stainless steel heat exchanger and electronic control module that allows fully condensing operation. The blowers pull in air and push flue products out of the boiler through the heat exchanger and flue piping. The control module regulates blower speeds to control the boiler firing rate. The gas valves sense the amount of air flowing into the boiler and allow only the right amount of gas to flow.

How the control modules operate

The Crest boiler is equipped with a SMART TOUCH control module. The SMART TOUCH control module receives inputs from boiler sensors and external devices. The control module activates and controls the blowers and gas valves to regulate heat input and switches the boiler, Hot Water Generator (HWG), and system pumps on and off as needed. The user programs the control module to meet system needs by adjusting control parameters. These parameters set operating temperatures and boiler operating modes.

Figure 1-2 Main Menu Screen

Lochinvar 3.5 — General Operation diagram (page 10)
Fig. 9 · General Operation

Table 1A (page 12) shows control module normal sequences of operation for space heating and HWG operation. The combined operation sequence is for a typical application, programmed to provide HWG priority.

The USER can adjust various space heating and HWG operating variables:

- Navigate to the Initial Setup Screen (FIG. 1-5). - From the Home Screen (FIG. 1-1), press MAIN MENU, then press SETUP on the Main Menu Screen (FIG. 1-2). - Press ENTER on the Password Screen (FIG. 1-3) (do not enter any values) and then press INITIAL SETUP on the Setup Screen (FIG. 1-4).

Figure 1-3 Password Screen

Lochinvar 3.5 — General Operation diagram (page 10)
Fig. 10 · General Operation

The USER can set the date and time and adjust temperature set points, and outdoor reset points.

Under the ADVANCED SETUP menu, the USER can change the TEMPERATURE UNITS and the LCD BACKLIGHT TIMER.

Most parameters are available only to the INSTALLER, accessible only by entering the installer password (5309) in the Password Screen (see the User Section).

Show 4 more labels / short text on this page
Sequence of operation · Access modes · User · Installer
Page 11 of the Lochinvar 3.5 user manual — 1 Service (continued)
Page 11 · click to enlarge
Page 11

1 Service (continued)

Saving parameters (reference the Parameter Table - Table 1B on pages 13 - 17 of this manual)

Figure 1-4 Setup Screen

Lochinvar 3.5 — 1 Service (continued) diagram (page 11)
Fig. 11 · 1 Service (continued)

To adjust and save parameters (reference FIG. 1-5):

To change a parameter, use the arrows next to the parameter list on the Menu Screen to highlight the desired parameter, then press SELECT. A short description of the parameter and its current setting are then displayed on the bottom half of the screen. To adjust the setting, use the buttons to the left and right of the current setting.

Press the SAVE button after adjusting a parameter value. Additional parameter settings can then be adjusted or other navigation buttons can be used to return to previous screens or the Home Screen (FIG. 1-1).

Figure 1-5 Initial Setup Screen

Lochinvar 3.5 — 1 Service (continued) diagram (page 11)
Fig. 12 · 1 Service (continued)
Page 12 of the Lochinvar 3.5 user manual — Sequence of operation
Page 12 · click to enlarge
Page 12

Table 1A Sequence of Operation

Sequence of operation

1.Upon a call for heat, the control turns on the appropriate pumps (system and boiler pumps for a space heating call, HW pump for a domestic hot water call). 2.The control confirms that the low water cutoff contacts are closed and energizes the louvers (optional) and damper (optional) relays. 3.The control confirms that the gas pressure switch, blocked drain switch, limits, louver proving switch (optional) and damper proving switch (optional) contacts close. The Pre-Purge cycle begins. 4.The control confirms both blowers come up to the desired speed, both blower proving switches close, and the air pressure switch is closed. 5.Once the Pre-Purge cycle is complete, the control lowers the blower speeds, initiates sparking of the ignition electrode, and opens Gas Valve 1. 6.After a short wait, the control stops sparking and checks for the presence of flame current through the flame sense electrode. 7.If the control does not detect flame current, the control will lockout indefinitely, until the RESET button on the touch screen LCD is pressed. Models FB 1500 - 2500 will have one retry. 8.If the control detects flame current, the control will hold the blower speed constant for a few seconds to allow the flame to stabilize, then begin modulating the firing rate in order to maintain the controlling sensor to the desired set point temperature. 9.If the current call for heat is for space heating and a HW call for heat becomes active, the control will turn on the HW pump relay output, then turn off the boiler pump. It will then modulate the blower speed in order to maintain the outlet temperature to the desired HW outlet set point temperature. 10.If the first combustion system in the boiler is unable to maintain the desired set point temperature, the second combustion system in the boiler will be started. Both blowers will modulate to a set speed, and the second gas valve will be energized. The second combustion system will light from the first combustion system. The second flame will be monitored much like the first. Once both combustion systems are firing, the control will work in synchronization to maintain the desired set point temperature. If the heat load should decrease sufficiently, the second combustion system will be shut down. 11.Once both the space heating and HW calls for heat are satisfied, the control will turn off the gas valve(s) and begin the Post-Purge cycle. Any pumps that are running will begin their respective Pump Delay cycles. 12.At the end of the Post-Purge cycle, the louver relay contacts will de-energize. 13.The control verifies that the blowers stop running and the blower proving switches open. 14.At the end of the Pump Delay cycle(s), the pump(s) will be turned off.
Page 13 of the Lochinvar 3.5 user manual — 1 Service (continued) Parameter table
Page 13 · click to enlarge
Page 13

1 Service (continued) Parameter table

Table 1B This table lists SMART TOUCH control module parameters and where to access them

Lochinvar 3.5 — 1 Service (continued) Parameter table diagram (page 13)
Fig. 13 · 1 Service (continued) Parameter table

3 SH Setpoint 18 32 185 120 Yes Yes

4 HWG Tank Setpoint 18 32 185 120 Yes Yes

5 MRHL Setpoint 18 32 205 205 Yes Yes

6 ARHL Setpoint 18 32 200 200 Yes Yes

7 SH Setpoint at Low Outdoor Temp. 19 32 185 180 Yes Yes

8 SH Setpoint at High Outdoor Temp. 19 32 185 68 Yes Yes

9 Low Outdoor Temperature 19 -22 86 23 Yes Yes

10 High Outdoor Temperature 19 -22 86 86 Yes Yes

11 Boiler Pump Mode 24 N/A N/A N/A No Yes

12 System Pump Mode 24 N/A N/A N/A No Yes

1 SH Min User Setpoint 18 32 185 32 No Yes

2 SH Max User Setpoint 18 32 185 185 No Yes

3 SH Setpoint 18 32 185 125 Yes Yes

4 SH Offset 18 0 36 9.9 No Yes

5 SH Differential 18 0 72 19.8 No Yes

6 HWG Tank Setpoint 18 32 185 120 Yes Yes

7 HWG Tank Differential 18 0 10 6.3 No Yes

8 MRHL Setting 18 32 205 204.8 Yes Yes

9 ARHL Setting 18 32 200 199.4 Yes Yes

10 HWG Minimum User Setpoint 19 32 185 60 No Yes

11 HWG Maximum User Setpoint 19 32 185 185 No Yes

12 HWG Boiler Setpoint 19 32 185 180 No Yes

13 HWG Boiler Offset 19 0 36 9.9 No Yes

14 HWG Boiler Differential 19 0 72 185 No Yes

1 SH Setpoint at Low Outdoor Temp. 19 32 185 180 Yes Yes

2 SH Setpoint at High Outdoor Temp 19 32 185 68 Yes Yes

3 Low Outdoor Temperature 19 -22 86 23 Yes Yes

4 High Outdoor Temperature 19 -22 86 86 Yes Yes

5 Outdoor Air Shutdown 19 32 122 79.7 No Yes

6 OA Shutdown Differential 20 32 122 79.7 No Yes

Page 14 of the Lochinvar 3.5 user manual — E
Page 14 · click to enlarge
Page 14

Parameter table

Table 1B (continued from previous page) This table lists SMART TOUCH control module parameters and where to access them

Min Max Default User Installer

Parameter Name (as shown on the LCD screen)

Value Value Value Access Access

OUTDOOR

7 Boost Time 20 0 250 20 No Yes

RESET RAMP DELAY BMS

8 Boost Temperature 20 0 25 0 No Yes

9 Shift OA Reset Curve 20 -27 27 0 No Yes

1 Ramp Delay Mode 20 N/A N/A N/A No Yes

2 Ramp Delay Time #1 20 1 40 2 No Yes

3 Ramp Delay Time #2 20 1 40 2 No Yes

4 Ramp Delay Time #3 20 1 40 2 No Yes

5 Ramp Delay Time #4 20 1 40 1 No Yes

6 Ramp Delay Time #5 20 1 40 1 No Yes

D

7 Ramp Delay Time #6 20 1 40 1 No Yes

8 Ramp Delay Limit #1 20 10 100 20 No Yes

9 Ramp Delay Limit #2 20 10 100 30 No Yes

10 Ramp Delay Limit #3 20 10 100 40 No Yes

11 Ramp Delay Limit #4 20 10 100 55 No Yes

12 Ramp Delay Limit #5 20 10 100 75 No Yes

13 Ramp Delay Limit #6 20 10 100 100 No Yes

1 BMS Active/Inactive 21 ACTIVE INACTIVE INACTIVE No Yes

2 BMS Mode 21 POWER SETPOINT POWER No Yes

3 BMS Volts at Min Rate 21 0 10 2 No Yes

4 BMS Volts at Max Rate 21 0 10 10 No Yes

5 BMS Rate at Min Volts 21 4 100 4 No Yes

6 BMS Rate at Max Volts 21 0 100 100 No Yes

E

7 BMS Volts at Min Setpoint 21 0 10 2 No Yes

8 BMS Volts at Max Setpoint 21 0 10 10 No Yes

9 BMS Setpoint at Min Volts 21 32 185 68.9 No Yes

10 BMS Setpoint at Max Volts 21 32 185 178.7 No Yes

11 BMS Volts to Enable 21 0 10 2 No Yes

12 Differential to Stop BMS Demand 21 0 10 0.5 No Yes

13 BMS Enable Mode 21 ENABLE VOLTAGE VOLTAGE No Yes

Menu Sub Item · See Page

Page 15 of the Lochinvar 3.5 user manual — G
Page 15 · click to enlarge
Page 15

1 Service (continued)

Parameter table

Table 1B (continued from previous page) This table lists SMART TOUCH control module parameters and where to access them

Min Max Default User Installer

Parameter Name (as shown on the LCD screen)

Value Value Value Access Access

1 Temperature Units 21 °F °C °F Yes Yes

2 LCD Backlight Time 21 0 255 240 Yes Yes

3 Freeze Protection; Pump On 21 -22 45 44.6 No Yes

4 Freeze Protection; Burner On 22 -22 45 37.4 No Yes

ADVANCED SETUP SH NIGHT SETBACK

5 Freeze Protection; Burner Diff 22 0 20 5 No Yes

6 HWG to SH Switching Time 22 0 240 30 No Yes

F

7 SH to HWG Switching Time 22 0 240 30 No Yes

8 Anti-Cycling Time 22 0 40 10 No Yes

9 Anti-Cycling Differential 22 0 40 1 No Yes

10 HWG Rate Limiting 22 10 100 100 No Yes

11 Service Mode Timeout 22 0 40 40 No Yes

12 Controlling Sensor 22 0 4 2 No Yes

13 Inlet Control Time Delay 22 0 40 3 No Yes

1 SH Night Setback Offset Temp 22 0 90 0 No Yes

2 SH Night Setback Mon End 22 N/A N/A N/A No Yes

3 SH Night Setback Mon Begin 22 N/A N/A N/A No Yes

4 SH Night Setback Tue End 22 N/A N/A N/A No Yes

5 SH Night Setback Tue Begin 22 N/A N/A N/A No Yes

6 SH Night Setback Wed End 22 N/A N/A N/A No Yes

7 SH Night Setback Wed Begin 22 N/A N/A N/A No Yes

G

8 SH Night Setback Thur End 22 N/A N/A N/A No Yes

9 SH Night Setback Thur Begin 22 N/A N/A N/A No Yes

10 SH Night Setback Fri End 22 N/A N/A N/A No Yes

11 SH Night Setback Fri Begiin 22 N/A N/A N/A No Yes

12 SH Night Setback Sat End 22 N/A N/A N/A No Yes

13 SH Night Setback Sat Begin 22 N/A N/A N/A No Yes

14 SH Night Setback Sun End 22 N/A N/A N/A No Yes

15 SH Night Setback Sun Begin 22 N/A N/A N/A No Yes

Menu Sub Item · See Page

Page 16 of the Lochinvar 3.5 user manual — J
Page 16 · click to enlarge
Page 16

Parameter table

Table 1B (continued from previous page) This table lists SMART TOUCH control module parameters and where to access them

Min Max Default User Installer

Parameter Name (as shown on the LCD screen)

Value Value Value Access Access

1 HWG Night Setback Offset Temp 22 0 90 0 No Yes

2 HWG Night Setback Mon End 22 N/A N/A N/A No Yes

3 HWG Night Setback Mon Begin 22 N/A N/A N/A No Yes

4 HWG Night Setback Tue End 22 N/A N/A N/A No Yes

5 HWG Night Setback Tue Begin 22 N/A N/A N/A No Yes

HWG NIGHT SETBACK CASCADE MOD

6 HWG Night Setback Wed End 22 N/A N/A N/A No Yes

7 HWG Night Setback Wed Begin 22 N/A N/A N/A No Yes

H

8 HWG Night Setback Thur End 22 N/A N/A N/A No Yes

9 HWG Night Setback Thur Begin 22 N/A N/A N/A No Yes

10 HWG Night Setback Fri End 22 N/A N/A N/A No Yes

11 HWG Night Setback Fri Begin 22 N/A N/A N/A No Yes

12 HWG Night Setback Sat End 22 N/A N/A N/A No Yes

13 HWG Night Setback Sat Begin 22 N/A N/A N/A No Yes

14 HWG Night Setback Sun End 22 N/A N/A N/A No Yes

15 HWG Night Setback Sun Begin 22 N/A N/A N/A No Yes

1 ModBus Active / Inactive 23 ACTIVE INACTIVE INACTIVE No Yes

BUS

2 ModBus Out of Order Timer 23 5 120 30 No Yes

1 Cascade Active / Inactive 23 ACTIVE INACTIVE INACTIVE No Yes

2 Cascade Address 23 0 7 1 No Yes

3 Cascade Offset 23 0 40 10 No Yes

4 Cascade Differential 23 0 72 20 No Yes

5 Max Boiler Setpoint for Cascade 23 32 185 185 No Yes

J

6 Cascade Type 23 N/A N/A N/A No Yes

7 Block Time Switching Boiler On / Off 23 0 255 60 No Yes

8 Minimum Next On Time 24 0 255 60 No Yes

9 Rate % to Switch On Next Boiler 24 1 100 80 No Yes

10 Rate % to Switch Off Last Boiler 24 1 100 10 No Yes

11 Number of Boiler Pumps Always On 24 0 8 0 No Yes

Menu Sub Item · See Page

Page 17 of the Lochinvar 3.5 user manual — Parameter table
Page 17 · click to enlarge
Page 17

1 Service (continued)

Parameter table

Table 1B (continued from previous page) This table lists SMART TOUCH control module parameters and where to access them

Lochinvar 3.5 — Parameter table diagram (page 17)
Fig. 14 · Parameter table

1 Boiler Pump Delay 24 0.5 2400 30 No Yes

2 Boiler Pump Anti-Seize Time 24 0 40 0.33 No Yes

3 Boiler Pump Mode 24 N/A N/A N/A No Yes

4 System Pump Mode 24 N/A N/A N/A No Yes

5 System Pump Delay 24 0.5 2400 30 No Yes

6 System Pump Anti-Seize Time 24 0 40 0.33 No Yes

7 HWG Pump Delay 24 0.5 2400 30 No Yes

8 HWG Pump Anti-Seize Time 24 0 40 0.33 No Yes

9 Delta T Setpoint 24 0 60 0 No Yes

1 Maintenance Notice - Months 25 0 36 12 No Yes

2 Maintenance Notice - Running Hours 25 0 100,000 10,000 No Yes

3 Maintenance Notice - Cycles 25 0 100,000 10,000 No Yes

4 Service Contact Number 25 N/A N/A N/A No Yes

5 Service Contact Name 25 N/A N/A N/A No Yes

Page 18 of the Lochinvar 3.5 user manual — Viewable and changeable control parameters
Page 18 · click to enlarge
Page 18

Viewable and changeable control parameters

The SH offset sets how many degrees above set point the temperature can go before the boiler will shut off. This parameter can only be changed by the installer by accessing parameter B4.

A: Initial Setup

The control uses an internal clock for the night setback feature and for logging of events. For these features to work correctly, the clock must be set when the boiler is first installed or anytime the boiler has been powered off for more than four (4) hours. This parameter must be accessed to set the clock. Parameter A2 sets the date.

The SH differential sets how many degrees below the offset the temperature has to drop before the boiler turns back on. This parameter can only be changed by the installer by accessing parameter B5.

HWG Tank Set Point

By installing a tank sensor, the SMART TOUCH control can perform the tank thermostat function. The SMART TOUCH control automatically detects the presence of this sensor, and generates a call for heat when the tank temperature drops below the tank set point minus the differential (parameter B7), and finishes the call for heat when the tank temperature reaches tank set point. This parameter can be changed by the installer by accessing parameter B6.

Parameters A3 - A12 shown in the Initial Setup Menu are grouped here for convenience. For a detailed explanation of each parameter, reference the specific menu for each parameter.

B: Set Points

Space Heating (SH) Minimum Set Point

The SH minimum set point sets the minimum water temperature set point that can be used for space heating operation. The user or installer will not be able to program the control with a lower SH set point. This parameter can only be changed by the installer by accessing parameter B1.

When a tank sensor is installed, the tank temperature must drop this amount below the tank set point (parameter B6) before the boiler will turn on. The installer can adjust this setting by accessing the parameter B7.

Manual Reset High Limit

Space Heating (SH) Maximum Set Point

The SMART TOUCH control contains an integral Manual Reset High Limit (MRHL) on the outlet of the heat exchanger. Once the outlet temperature exceeds the MRHL set point, the boiler will shut down and lock out. Once the outlet temperature has dropped below this set point, the RESET button on the LCD display must be pressed to clear this lockout. This set point can be adjusted by accessing parameter B8.

The SH maximum set point sets the maximum water temperature set point that can be used for space heating. The user or installer will not be able to program the control with a higher SH set point. This parameter can only be changed by the installer by accessing parameter B2.

Space Heating (SH) Set Point

Auto Reset High Limit

The SH set point sets the water temperature set point used during space heating calls. This parameter can be changed by the installer by accessing parameter B3.

The SMART TOUCH control contains an integral Auto Reset High Limit (ARHL) on the outlet of the heat exchanger. Once the outlet temperature exceeds the ARHL set point, the boiler will shut down and lock out. Once the outlet temperature has dropped below this set point, the RESET button on the LCD display can be pressed to reset this lockout. If RESET is not pressed, the control will automatically reset the lockout after five (5) minutes. This set point can be adjusted by accessing parameter B9.

Show 4 more labels / short text on this page
SH Offset · Clock and Date · SH Differential · HWG Tank Differential
Page 19 of the Lochinvar 3.5 user manual — 1 Service (continued)
Page 19 · click to enlarge
Page 19

1 Service (continued)

C: Outdoor Reset

HWG Minimum User Set Point

SH Set Point at Low Outdoor Temperature

This setting controls the minimum user set point for the tank temperature. The installer can adjust this by accessing parameter B10.

When the outdoor air temperature drops to or below the Low Outdoor Temperature setting (parameter C3), the water temperature will be at this setting (see FIG. 1-6). However, if the user set point is set lower, the water temperature will be limited by the user set point instead. This parameter can be changed by accessing parameter C1.

HWG Maximum User Set Point

This setting controls the maximum user set point for the tank temperature. The installer can adjust this by accessing parameter B11.

SH Set Point at High Outdoor Temperature

When the outdoor air temperature rises to or above the High Outdoor Temperature setting (parameter C4), the water temperature will be at this setting (see FIG. 1-6). This parameter can be changed by accessing parameter C2.

HWG Boiler Set Point

When a HWG call for heat becomes active, the control will use the HWG boiler set point to determine the firing rate of the boiler based on the boiler outlet water temperature.

This parameter can be changed by the installer by accessing parameter B12.

When the outdoor air temperature drops to its minimum (C3), the water temperature will be at parameter C1 (FIG. 1-6). As the outdoor temperature continues to drop, the water temperature set point will continue to rise. However, if the user set point is set lower, the water temperature will be limited by the user set point instead. This parameter can be changed by accessing parameter C3.

This parameter reflects the degrees above HWG boiler set point the outlet temperature can go before the boiler will shut off. This parameter can be changed by the installer by accessing parameter B13.

High Outdoor Temperature When the outdoor air temperature rises to or above this set point, the water temperature will be at parameter C2 (FIG. 1-6). This parameter can be changed by the installer by accessing parameter C4.

This parameter reflects the degrees below HWG boiler offset the outlet temperature has to go before the boiler turns on. This parameter can be changed by the installer by accessing parameter B14.

When the outdoor temperature rises above this point, the control will block all SH demands (HWG demands will still be active). This parameter can be changed by the installer by accessing parameter C5.

Figure 1-6 Outdoor Air Reset Curve

Lochinvar 3.5 — 1 Service (continued) diagram (page 19)
Fig. 15 · 1 Service (continued)
Show 4 more labels / short text on this page
Low Outdoor Temperature · HWG Boiler Offset · HWG Boiler Differential · Outdoor Air Shutdown
Page 20 of the Lochinvar 3.5 user manual — Viewable and changeable control parameters
Page 20 · click to enlarge
Page 20

Outdoor Air Shutdown Differential

Shift OA Reset Curve

The outdoor air shutdown differential parameter is the number of degrees below parameter C5 the outdoor air temperature must go before the boiler will respond to a SH demand. This parameter can be changed by the installer by accessing parameter C6.

The shift reset curve parameter shifts the actual set point above or below the calculated set point by the number of degrees in this parameter. This parameter can be changed by the installer by accessing parameter C9.

D: Ramp Delay

Ramp Delay (Enable / Disable)

The boost time parameter sets the amount of time that must elapse with a SH demand before the water temperature calculated set point will be increased. This parameter can be changed by the installer by accessing parameter C7.

This parameter allows the installer to enable or disable the SH ramp delay by accessing parameter D1.

The SMART TOUCH control can be programmed to limit the firing rate for a fixed period of time at the start of a space heating demand. There are six (6) possible limits, each with their own time delay. The first limit applies as soon as the burner starts. Once its time delay expires, the second limit is applied and its timer begins. The control steps through these limits until the 6th (sixth) limit expires. Note, however, that the 6th limit will also limit the rate for the rest of that heat demand. The installer can adjust the firing limits and time delays by accessing parameters D2 through D13.

If a SH demand lasts longer than the programmed boost time delay setting (C7) and there have been no HWG demands, the control will increase the water temperature set point by the amount in this parameter. If the SH demand continues through another time period, the set point will be increased again. This will continue until either the SH demand ends, a maximum of 20 increases has occurred, or the maximum set point has been reached. Once the SH demand has been satisfied the set point will revert back to its calculated setting. The boost temperature can be changed by the installer by accessing parameter C8.

Figure 1-7 Ramp Delay Interval

Lochinvar 3.5 — Viewable and changeable control parameters diagram (page 20)
Fig. 16 · Viewable and changeable control parameters

Boost Time · SH Ramp Delay · Boost Temperature

Page 21 of the Lochinvar 3.5 user manual — E: BMS
Page 21 · click to enlarge
Page 21

1 Service (continued)

E: BMS

BMS Set Point at Maximum Volts

When programmed for BMS control through the 0 - 10V BMS input or through ModBus and the BMS Type is programmed as SETPOINT, the set point represented by the Volts at Maximum parameter (E8) is set by parameter E10.

BMS (Active / Inactive)

The set point or modulation of the boiler may be controlled through the 0 - 10V BMS input or through ModBus. When parameter E1 set to INACTIVE, the 0 - 10V input will be ignored. When set to ACTIVE, the set point or modulation will be controlled by the voltage on the 0 - 10V input (in the case of 0 - 10V BMS control), or the 0 - 10V input value received through ModBus.

BMS Volts to Enable

When programmed for BMS control through the 0 - 10V BMS input or through ModBus and the BMS Enable Mode is set to INACTIVE, parameter E11 determines the 0 - 10V BMS input voltage at which the boiler is enabled.

BMS Mode (Power / Set Point)

When programmed for BMS control through the 0 - 10V BMS input or through ModBus, the 0 - 10V signal can be interpreted as either a modulation command or a set point. When parameter E2 is set to POWER, the 0 - 10V signal will control the modulation. When set to SETPOINT, the 0 - 10V signal will control the SH set point.

Differential to Stop BMS Demand

When programmed for BMS control through the 0 - 10V BMS input or through ModBus and the BMS Enable Mode is set to INACTIVE, parameter E12 determines how far below the On Volts setting E11 the 0 - 10V BMS input voltage must be in order to disable the boiler.

BMS Volts at Minimum (Rate or Set Point)

When programmed for BMS control through the 0 - 10V BMS input or through ModBus, parameters E3 or E7 should be set to the minimum voltage signal sent to the SMART TOUCH control.

When controlling the boiler through the 0 - 10V BMS input or through ModBus, the boiler can be enabled one of two ways. With parameter E13 set to ACTIVE, the boiler will be enabled by closing the Enable input. When parameter E13 is set to INACTIVE, the boiler will be enabled by the voltage level on the 0 - 10V input (in the case of 0 - 10V BMS control), or the 0 - 10V input value received through ModBus.

BMS Volts at Maximum (Rate or Set Point)

When programmed for BMS control through the 0 - 10V BMS input or through ModBus, parameter E4 or E8 should be set to the maximum voltage signal sent to the SMART TOUCH control.

F: Advanced Setup

Temperature units (°C / °F)

BMS Rate at Minimum Volts

The control can be configured to display temperature in either °C or °F. This parameter can be changed by the user or the installer by accessing parameter F1.

When programmed for BMS control through the 0 - 10V BMS input or through ModBus and the BMS Type is programmed as POWER, the modulation percentage represented by the Volts at Minimum parameter (E3) is set by parameter E5.

Display Timeout (LCD Backlight Time)

This is the time in which the display remains illuminated. This parameter can be changed by the user or the installer by accessing parameter F2.

BMS Rate at Maximum Volts

When programmed for BMS control through the 0 - 10V BMS input or through ModBus and the BMS Type is programmed as POWER, the modulation percentage represented by the Volts at Maximum parameter (E4) is set by parameter E6.

Freeze Protection Pump On

The SMART TOUCH control will turn on the boiler and system pump outputs whenever the inlet temperature drops below this setting. This is done to prevent the water in the heat exchanger from freezing. Certain low-temperature applications (such as snow melt) can operate at temperatures around freezing, so this setting needs to be lowered in these cases. The installer can adjust the temperature at which the pump outputs are turned on by accessing parameter F3.

BMS Set Point at Minimum Volts

When programmed for BMS control through the 0 - 10V BMS input or through ModBus and the BMS Type is programmed as SETPOINT, the set point represented by the Volts at Minimum parameter (E7) is set by parameter E9.

BMS Enable Mode

Page 22 of the Lochinvar 3.5 user manual — E: BMS
Page 22 · click to enlarge
Page 22

Freeze Protection Burner On

HWG Rate Liming (NOT AVAILABLE AT THIS TIME)

This parameter determines the maximum rate to be used when heating a HWG tank. This setting may be used when the tank is unable to accept all of the BTU’s available from the boiler. This parameter may be adjusted by the installer by accessing parameter F10.

If running the pumps does not prevent the inlet temperature from falling closer to freezing, the SMART TOUCH control will fire the burner at low fire if in the ON state. The installer can adjust the temperature at which the burner fires by adjusting parameter F4.

Freeze Protection Burner Differential

The Service Mode allows the installer to set the unit to any firing rate for the purpose of combustion analysis. The delay sets the length of time the boiler will stay in the Service Mode if no keys have been pressed before going back to its original state. This parameter can only be changed by the installer by accessing parameter F11.

Once the burner has started firing due to a low inlet temperature, the inlet temperature must increase by this amount before the burner turns back off. The installer can adjust this differential by accessing parameter F5.

When a boiler has a HWG demand and it receives a space heating demand, the SMART TOUCH control will start a timer. Once the timer expires, it will stop the HWG demand and service the space heating demand. The installer can adjust the length of time the boiler will service the HWG demand by accessing parameter F6.

The SH controlling sensor parameter selects the sensor the control will use to regulate the boiler firing rate. This parameter is adjustable by the installer by accessing parameter F12. The sensor selections are as follows: The outlet sensor regulates the firing rate based on the outlet water temperature of the boiler and the inlet sensor regulates the firing rate based on the inlet water temperature of the boiler. If the outlet sensor is selected, and the optional system supply sensor is connected, the control will regulate the firing rate based on the system supply sensor temperature.

When a boiler has a space heating demand and it receives a HWG demand, it will immediately switch to the HWG demand and start a timer. Once the timer has expired, the boiler will switch back to the space heating demand and start another timer. Once this timer expires, it will switch back to the HWG demand. The installer can adjust the length of time the boiler will service the space heating demand by accessing parameter F7.

Inlet Control Time Delay

When the inlet sensor is selected as the controlling sensor, the SMART TOUCH control will start by controlling the outlet/ system supply temperature to the SH set point. After a time delay, the control will start to increase and regulate the system supply temperature in order to maintain the inlet/system return temperature to the SH set point. This time delay should be long enough for the heated water to work its way through the system loop and be measured by the inlet/system return sensor. This time delay is adjustable by the installer by accessing parameter F13.

Once a SH demand has been satisfied, a set amount of time must elapse before the control will respond to a new SH demand. The control will block the new heat demand and anti-cycling will be shown in the display until the time has elapsed or the water temperature drops below parameter F9. This parameter can be changed by the installer by accessing parameter F8.

G/HSH/HWG Night Setback

The installer may adjust the space heating night setback offset by accessing parameter G1 and the HWG night setback offset by accessing parameter H1.

The control will bypass the anti-cycling time if the inlet water temperature drops too much. The control will use the inlet water temperature at the time the boiler shut off as the starting point. If the inlet temperature drops below this temperature parameter the control will abort anti- cycling and allow the boiler to fire. This parameter can be changed by the installer by accessing parameter F9.

Once the internal clock has been set correctly, the SH night setback feature can be used to program a lower set point. The value of this parameter will be subtracted from the normal set point to determine the set point used during night setback. This parameter can be changed by the user or the installer by accessing parameters G2 through G15 and H2 through H15. The temperature range for this parameter is 0°F to 90°F (50°C). The feature is turned off with a setting of 0°F.

Show 6 more labels / short text on this page
Service Mode Timeout · HWG/SH Switching Time · Controlling Sensor · SH/HWG Switching Time · Anti-Cycling Time · Anti-Cycling Differential
Page 23 of the Lochinvar 3.5 user manual — Cascade Offset
Page 23 · click to enlarge
Page 23

1 Service (continued)

I: ModBus

ModBus (Active / Inactive)

This parameter determines how much the temperature must go below the turn off temperature (Set point + Offset) before the lead boiler turns on. This parameter can be adjusted by the installer by accessing parameter J4.

When BMS is set to ACTIVE (see BMS Active / Inactive) and the boiler is being controlled through ModBus, set parameter I1 to ACTIVE. Otherwise, set the ModBus parameter to INACTIVE. Note that the boiler can still be monitored by ModBus with this parameter set to INACTIVE.

Maximum Boiler Set Point for Cascade

This parameter determines the set point used by the individual boilers in a Cascade. When a boiler is commanded to fire by the Leader boiler, it will attempt to achieve this temperature at its outlet. If any of the boiler outlet temperatures reach the maximum cascade set point, the boiler will then modulate down on its own in order to keep its outlet temperature within the maximum cascade set point. Therefore, this parameter can be used to limit the outlet temperatures of all the boilers in a Cascade. Note that this parameter does not apply when the boiler is heating an indirect HWG tank. This parameter is adjustable by the installer by accessing parameter J5.

ModBus Out of Order Timer

When the boiler is being provided with certain commands and temperatures through ModBus, this information must be updated frequently. If it is not updated before this timer expires, the boiler will revert back to its own internal readings and control. This parameter is adjustable by the installer by accessing parameter I2.

J: Cascade

Cascade Type The Cascade divider method is Efficiency Optimization, designated as EFF in the menu. This method is used, as the name implies, when it is desired to have the most efficient system. When the first boiler reaches a certain rate (default = 80%), it lowers its rate to 40% and turns on the next boiler at 40%. The two (2) boilers then modulate at the same rate. As the calculated load increases further and both boilers ramp up to 80%, it lowers the rate of the first two (2) boilers to 53% and brings the next boiler on at 53%. The three (3) boilers then modulate together. As the calculated load decreases, the boilers will reach a lower threshold (default = 10%), at which time the last boiler (the third in our example) will turn off and the Cascade will increase the rates of the remaining boilers to provide the equivalent total output as before ((3 x 10%) / 2 = 15% in our example). This parameter can be adjusted by the installer by accessing parameter J6.

Cascade Active / Inactive

The boiler is part of a group of units sequenced together. The designated Leader unit determines the total output needed from the group based on the set point and controlling sensor reading. It assigns portions of the output to itself (Leader) and the Member units. When Cascade is active, each boiler in the group requires a unique address. This setting is adjustable by the installer by accessing parameter J1.

The boiler designated as the Leader needs to be programmed with address 0. All the Member boilers require addresses from 1 to 7, and the addresses must be different for each Member. The addresses can be in any order, regardless of the order in which the units are wired together. This parameter is adjustable by the installer by accessing parameter J2. The outdoor air (if used) and system supply sensor must be connected to the Leader boiler.

Minimum On/Off Time

In order to prevent units in a Cascade from short cycling, this parameter defines the minimum ON and OFF time for each unit. The installer can adjust this time by accessing parameter J7.

Cascade Offset

This parameter determines how much the temperature can go above set point before the lead boiler will turn off. This parameter can be adjusted by the installer by accessing parameter J3.

Cascade Off-On Differential · Cascade Address

Page 24 of the Lochinvar 3.5 user manual — Minimum On/Off Time
Page 24 · click to enlarge
Page 24

Minimum Next On Time

In order to reduce the risk of temperature overshoot with a Cascade, this parameter defines the minimum time delay from starting one unit until the next unit may be started. The installer can adjust this time delay by accessing parameter J8.

The SMART TOUCH control is able to control the system pump in 5 different ways. The options are as follows:

1. ON with a call for heat, with a constant speed. 2. ON with a call for heat, with a variable speed input. 3. Always ON, with a constant speed, except during outdoor shutdown. 4. Always ON, with a variable speed input, except during outdoor shutdown. 5. Always OFF (not connected).

Rate % to Switch on Next Boiler

When the Cascade is programmed in the Efficiency Optimization Mode, the currently running boilers must ramp up to a certain firing rate before the next boiler in the Cascade will start. This percentage can be adjusted by accessing parameter J9.

For options 2 and 4, the speed of the system pump is controlled by a separate control system. The System Pump Mode can be adjusted by accessing parameter K4.

Rate % to Switch off Last Boiler

When the Cascade is programmed in the Efficiency Optimization Mode, the currently running boiler will stop. This percentage can be adjusted by accessing parameter J10.

The system pump delay parameter sets the length of time the system pump (if connected) will run after a SH demand has been satisfied. This parameter is adjustable by the installer by accessing parameter K5.

Number of Boiler Pumps Always On

When multiple Crest boilers are connected in a Cascade, the SMART TOUCH control can keep a minimum number of the boiler pumps running, regardless of how many of the boilers are firing. This is useful in full flow systems where the system flow is provided by the individual boiler pumps. This number can be adjusted by accessing parameter J11.

System Pump Anti-Seize Delay

If the boiler pump does not run for 24 hours, it will be turned on briefly to prevent it from seizing. The length of time it runs is determined by parameter K6.

K: Pumps

The HWG pump delay parameter sets the length of time the HWG pump (if connected) will run after a HWG demand has been satisfied. This parameter is adjustable by the installer by accessing parameter K7.

The SH pump delay parameter sets the length of time the boiler pump will run after a SH demand has been satisfied. This parameter is adjustable by the installer by accessing parameter K1.

HWG Pump Anti-Seize Delay

If the boiler pump does not run for 24 hours, it will be turned on briefly to prevent it from seizing. The length of time it runs is determined by parameter K8.

Boiler Pump Anti-Seize Time

If the boiler pump does not run for 24 hours, it will be turned on briefly to prevent it from seizing. The length of time it runs is determined by parameter K2.

ΔT Set Point

The SMART TOUCH control includes a 0 - 10Vdc output for controlling the speed of a variable speed boiler pump. The speed is regulated in order to, among other things, maintain a minimum delta T across the heat exchanger. This helps reduce the electrical consumption of the boiler pump when the boiler is firing at less than its maximum rate. (This feature is active only when a system supply sensor is installed). This set point can be adjusted by accessing parameter K9.

The SMART TOUCH control is able to control the boiler pump in 3 different ways. The options are as follows:

1. ON with a call for heat, with a constant speed. 2. ON with a call for heat, with a variable speed output. 3. Always OFF (not connected).

The Boiler Pump Mode can be adjusted by accessing parameter K3.

Show 5 more labels / short text on this page
System Pump Mode · System Pump Delay · HWG Pump Delay · Boiler Pump Delay · Boiler Pump Mode
Page 25 of the Lochinvar 3.5 user manual — 1 Service (continued)
Page 25 · click to enlarge
Page 25

1 Service (continued)

L: Service Notification

Service Notification in Months

When the boiler control determines that a scheduled service is due based on the months of installation, the boiler display will turn yellow and a new status screen will appear informing the installer that maintenance is required. This parameter is adjustable by the installer by accessing parameter L1.

Service Notification Running Hours

When the boiler control determines that a scheduled service is due based on the hours of actual operation, the boiler display will turn yellow and a new status screen will appear informing the installer that maintenance is required. This parameter is adjustable by the installer by accessing parameter L2.

When the boiler control determines that a scheduled service is due based on the number of boiler cycles, the boiler display will turn yellow and a new status screen will appear informing the installer that maintenance is required. This parameter is adjustable by the installer by accessing parameter L3.

Installer Name and Phone Number

When a Maintenance Reminder timer or counter has expired, a Maintenance Reminder screen will appear on the display. By programming the installer’s name and phone number, this information will appear on the Maintenance Reminder Screen at that time. This can be programmed by accessing parameters L4 and L5. When selected, another menu will appear with PHONE and NAME.

Service Notification Cycles

Page 26 of the Lochinvar 3.5 user manual — Cascade Screen
Page 26 · click to enlarge
Page 26

Cascade Screen

Figure 1-8 Cascade Screen

Lochinvar 3.5 — Cascade Screen diagram (page 26)
Fig. 17 · Cascade Screen

The Cascade Screen provides the status of the Cascade System. This screen is only accessible when the boiler is the Leader of an active Cascade. There are many items displayed on the Cascade Screen. Among them is the Boiler Power Level Indicators. For each boiler present in the Cascade a power level indicator will be present above its corresponding Cascade address. The level of the indicator will rise and fall indicating the approximate power level of the boiler. The display box above each power level will display the following:

  • “ 100%” – A percentage indicates that fi ring rate of the corresponding boiler.
  • “____” – A blank fi eld indicates that the corresponding boiler has lost communication.
  • “Error” – Error indicates that the corresponding boiler is in Lockout.
  • “Off” – Off indicates that the corresponding boiler is turned off.
  • “HWG” – HWG indicates that the corresponding boiler is supplying a hot water generator demand.
  • “Frost” – Frost indicates that the corresponding boiler is in frost protection and is not being controlled by the Leader.
  • “- - “ – Two dash marks indicate that there is not a demand for the corresponding boiler.
Page 27 of the Lochinvar 3.5 user manual — 1 Service (continued)
Page 27 · click to enlarge
Page 27

1 Service (continued)

Graph Screen

The Graph Screen consists of two (2) different screens. The First screen is the Parameter Selection Screen. By pressing the up and down arrow keys the desired parameter can be selected. When the SELECT button is pressed the parameter will appear in the bottom half of the fi rst screen. If a parameter is selected by mistake, it can be de-selected by highlighting the parameter and pressing the SELECT button. A maximum of fi ve (5) items can be graphed at one time.

Figure 1-9 Graph Screen_Parameter Selection

Lochinvar 3.5 — 1 Service (continued) diagram (page 27)
Fig. 18 · 1 Service (continued)

The Second screen is accessed by pressing the GRAPH button. Once the items to be graphed are selected, press the GRAPH button to view the graph. Each item graphed will have a different color line to represent it. The items selected will be shown below the graph along with their corresponding color. Press the BACK button to return to the Parameter Selection Screen.

Figure 1-10 Graph Screen

Lochinvar 3.5 — 1 Service (continued) diagram (page 27)
Fig. 19 · 1 Service (continued)
Page 28 of the Lochinvar 3.5 user manual — History Screen
Page 28 · click to enlarge
Page 28

History Screen

The History Screen shows the status of various counters and faults. Within the History Screen there are three separate screens. These screens are the “Lockout Faults”, “Blocking Faults” and “Runtime History”.

The default screen is the “Lockout Faults” screen. This screen allows you to view the last ten (10) lockout faults. Preceded by each fault is the date and time of when the fault occurred. The lockout faults can be reset by pressing the RESET FAULTS button.

Figure 1-11 History Screen_Lockout Faults

Lochinvar 3.5 — History Screen diagram (page 28)
Fig. 20 · History Screen

The next screen is the “Blocking Faults” Screen. This screen allows you the view the last ten (10) blocking faults. Preceded by each fault is the date and time of when the fault occurred. The blocking faults can be reset by pressing the RESET FAULTS button.

Figure 1-12 Graph Screen_Blocking Faults

Lochinvar 3.5 — History Screen diagram (page 28)
Fig. 21 · History Screen
Page 29 of the Lochinvar 3.5 user manual — 1 Service (continued)
Page 29 · click to enlarge
Page 29

1 Service (continued)

History Screen

The third screen is the “Runtime History”. There are several pieces of information that are displayed on this screen. Items that can be viewed on this screen are as follows:

  • Power hours – Shows the number of hours the control has been powered on since the last reset.
  • Running hours – Shows the number of hours that the boiler has been fi ring since the last reset.
  • Ignition attempts – Shows the number of times the control has attempted to ignite since the last reset.
  • Successful Ignition attempts - Shows the number of times the control has successfully ignited since the last reset.
  • Total Power hours – Show the total number of hours the control has been powered.
  • Total Running hours – Show the total number of hours that the boiler has been fi ring.
  • Total ignition attempts – Show the total number of times the control has attempted to ignite.
  • Total Successful ignition attempts – Show the total number of times the control has successfully ignited. The top left of this screen details the running hours based on 4 different running positions.

Figure 1-13 History Screen_Runtime History

Lochinvar 3.5 — 1 Service (continued) diagram (page 29)
Fig. 22 · 1 Service (continued)
Page 30 of the Lochinvar 3.5 user manual — 1 Service (continued)
Page 30 · click to enlarge
Page 30

1 Service (continued)

Service Screen

The Service Screen allows the integrated control to override all other heat demands and operate Valve 1 and Valve 2 at high fi re and low fi re conditions. To place the boiler into Service Mode, press the START button. As specifi ed above the integrated control will override all other heat demands, however, all safeties will be active. If no buttons are pressed, the integrated control will automatically revert back to its original status after the “Remaining time in Servicer” counter expires.

Once the boiler has been placed into Service Mode it will light and modulate to low fi re. At any time after that point there are two (2) ways to adjust the fi ring rate. The fi rst way is by pressing one of the six (6) preset buttons. The second way is by manually adjusting the fi ring percentage using the “+” and “-“ buttons. When Service Mode is no longer needed press the STOP button to return to normal operation.

Figure 1-14 Service Screen

Lochinvar 3.5 — 1 Service (continued) diagram (page 30)
Fig. 23 · 1 Service (continued)
Page 31 of the Lochinvar 3.5 user manual — End of season
Page 31 · click to enlarge
Page 31

2 Maintenance

Maintenance and annual startup

Table 2A Service and Maintenance Schedules

Service technician (see the following pages for instructions)

Owner maintenance (see the Crest User’s Information Manual for

General:

  • Address reported problems, if any
  • Check boiler area
  • Inspect interior; clean and vacuum if necessary;

Daily

  • Check pressure/temperature gauge
  • Clean condensate trap and fill with fresh water
  • Check for leaks (water, gas, flue, condensate)
  • Verify flue and air lines in good condition and sealed tight
  • Check vent piping
  • Check system water pressure/system piping/expansion tank
  • Check air piping

Monthly

  • Check air and vent termination screens
  • Check relief valve

ANNUAL START-UP

  • Check control settings
  • Check the ignition and both flame sense electrodes (sand off any deposits; clean and reposition)
  • Check condensate drain system
  • Check wiring and connections
  • Perform start-up checkout and performance verification per Section 9 of the Crest Installation and Operation Manual.
  • Test low water cutoff
  • Reset button (low water cutoff)
  • Check boiler piping (gas and water) for leaks
  • Flame inspection (stable, uniform)

Every 6 months

  • Check both flame signals (at least 10 microamps at high fire)
  • Test low water cutoff.
  • Operate relief valve

If combustion or performance indicate need:

  • Shut boiler down (unless boiler used for domestic hot water)
  • Clean heat exchanger
  • Remove and clean burner using compressed air only

End of season

months

  • Clean the blower wheels

instructions)

Page 32 of the Lochinvar 3.5 user manual — Clean condensate trap
Page 32 · click to enlarge
Page 32

2 Maintenance

Follow the service and maintenance procedures given throughout this manual and in component literature shipped with the boiler. Failure to perform the service and maintenance could result in damage to the boiler or system. Failure to follow the directions in this manual and component literature could result in severe personal injury, death, or substantial property damage.

WARNING

WARNING

The boiler should be inspected annually only by a qualified service technician. In addition, the maintenance and care of the boiler designated in Table 2A and explained on the following pages must be performed to assure maximum boiler efficiency and reliability. Failure to service and maintain the boiler and system could result in equipment failure.

Electrical shock hazard – Turn off power to the boiler before any service operation on the boiler except as noted otherwise in this instruction manual. Failure to turn off electrical power could result in electrical shock, causing severe personal injury or death.

WARNING

Address reported problems

Figure 2-1 Condensate Trap

Lochinvar 3.5 —  WARNING diagram (page 32)
Fig. 24
1. Inspect any problems reported by the owner and correct before proceeding.

Inspect boiler area

FROM CONDENSATE DRAIN ON BOILER TO FLOOR DRAIN OR NEUTRALIZER KIT 1” PVC / CPVC CONNECTION

1. Verify that boiler area is free of any combustible materials, gasoline and other flammable vapors and liquids.
2. Verify that air intake area is free of any of the contaminants listed in Section 1 of this manual. If any of these are present in the boiler intake air vicinity, they must be removed. If they cannot be removed, reinstall the air and vent lines per this manual.

Check all piping for leaks

Eliminate all system or boiler leaks. Continual fresh makeup water will reduce boiler life. Minerals can build up, reducing heat transfer, overheating heat exchanger, and causing heat exchanger failure. Leaking water may also cause severe property damage.

WARNING

Inspect boiler interior

1. Remove the front access covers and inspect the interior of the boiler.
1. Inspect all water and gas piping and verify to be leak free.
2. Vacuum any sediment from inside the boiler and components. Remove any obstructions.
2. Look for signs of leaking lines and correct any problems found.

Clean condensate trap

3. Check gas line using the procedure found in Section 6 - Gas Connections of the Crest Installation and Operation Manual .
1. Inspect the condensate drain line, vent line, condensate PVC fittings, and condensate trap.

Flush condensate trap with water

1. Remove the four (4) screws securing the top cover to the condensate trap and remove the cover (FIG. 2-1).
2. Locate the plastic ball inside the float tube. Verify there is nothing under the ball causing it to not seat properly.
3. Fill with fresh water until the water begins to pour out of the drain.
4. Replace the top cover and the screws removed in Step 1.
Page 33 of the Lochinvar 3.5 user manual — Check boiler relief valve
Page 33 · click to enlarge
Page 33

2 Maintenance (continued)

Flue vent system and air piping

Safety relief valves should be re-inspected AT LEAST ONCE EVERY THREE YEARS, by a licensed plumbing contractor or authorized inspection agency, to ensure that the product has not been affected by corrosive water conditions and to ensure that the valve and discharge line have not been altered or tampered with illegally. Certain naturally occurring conditions may corrode the valve or its components over time, rendering the valve inoperative. Such conditions are not detectable unless the valve and its components are physically removed and inspected. This inspection must only be conducted by a plumbing contractor or authorized inspection agency – not by the owner. Failure to re-inspect the boiler relief valve as directed could result in unsafe pressure buildup, which can result in severe personal injury, death, or substantial property damage.

WARNING

1. Visually inspect the entire flue gas venting system and air piping for blockage, deterioration or leakage. Repair any joints that show signs of leakage. Verify that air inlet pipe is connected and properly sealed.
2. Verify that boiler vent discharge and air intake are clean and free of obstructions.

WARNING

Failure to inspect for the above conditions and have them repaired can result in severe personal injury or death.

Check water system

1. Verify all system components are correctly installed and operational.
2. Check the cold fill pressure for the system. Verify it is correct (must be a minimum of 12 psi (82.7 kPa)).
3. Watch the system pressure as the boiler heats up (during testing) to ensure pressure does not rise too high. Excessive pressure rise indicates expansion tank sizing or performance problem.

Following installation, the valve lever must be operated AT LEAST ONCE A YEAR to ensure that waterways are clear. Certain naturally occurring mineral deposits may adhere to the valve, rendering it inoperative. When manually operating the lever, water will discharge and precautions must be taken to avoid contact with hot water and to avoid water damage. Before operating lever, check to see that a discharge line is connected to this valve directing the flow of hot water from the valve to a proper place of disposal. Otherwise severe personal injury may result. If no water flows, valve is inoperative. Shut down the boiler until a new relief valve has been installed.

WARNING

4. Inspect automatic air vents and air separators. Remove air vent caps and briefly press push valve to flush vent. Replace caps. Make sure vents do not leak. Replace any leaking vents.

Check expansion tank

1. Expansion tanks provide space for water to move in and out as the heating system water expands due to temperature increase or contracts as the water cools. Tanks may be open, closed or diaphragm or bladder type. See Section 5 - Hydronic Piping of the Crest Installation and Operation Manual for suggested best location of expansion tanks and air eliminators.
2. After following the above warning directions, if the relief valve weeps or will not seat properly, replace the relief valve. Ensure that the reason for relief valve weeping is the valve and not over-pressurization of the system due to expansion tank waterlogging or undersizing.

Check boiler relief valve

1. Inspect the relief valve and lift the lever to verify flow. Before operating any relief valve, ensure that it is piped with its discharge in a safe area to avoid severe scald potential. Read Section 5 - Hydronic Piping of the Crest Installation and Operation Manual before proceeding further.
Page 34 of the Lochinvar 3.5 user manual — Check burner flame
Page 34 · click to enlarge
Page 34

2 Maintenance

Inspect ignition and flame sense electrodes

  • Shut down the boiler: - Follow the “To Turn Off Gas to Appliance” instructions for the boiler in Section 9 - Startup of the Crest Installation and Operation Manual. - Do not drain the boiler unless it will be exposed to freezing temperatures. If using freeze prevention fluid in system, do not drain. 3. Allow time for the boiler to cool to room temperature if it has been firing.
1. Remove the ignition and both flame sense electrodes from the burner plate.
2. Remove any deposits accumulated on the ignition/ flame sense electrodes using sandpaper. If the electrodes cannot be cleaned satisfactorily, replace with new ones.
4. Remove the top access panel to remove the gas/air manifold assembly.
3. Replace ignition/flame sense electrodes, making sure the gaskets are in good condition and correctly positioned.
5. Remove the nuts securing the burner to the burner mounting plate. Remove the burner (FIG. 2-2).

Check ignition ground wiring

6. When replacing the burner, ensure gaskets are in good condition and positioned correctly (FIG. 2-2).
1. Inspect boiler ground wire from the heat exchanger access cover to ground terminal strip.
7. When securing the burner, be sure to tighten the nuts, but DO NOT over-tighten. Tighten the nuts to a torque setting of no more than 6.2 ft.-lbs. When securing the burner mounting plate be sure to tighten the nuts, but DO NOT over-tighten. Tighten the nuts to a torque setting of no more than 15.5 ft.-lbs.
2. Verify all wiring is in good condition and securely attached.
3. Check ground continuity of wiring using continuity meter.

Figure 2-2 Burner Assembly

4. Replace ground wires if ground continuity is not satisfactory.
Lochinvar 3.5 — Check ignition ground wiring diagram (page 34)
Fig. 25 · Check ignition ground wiring

Check all boiler wiring

1. Inspect all boiler wiring, making sure wires are in good condition and securely attached.

Check control settings

1. Navigate to the Setup Screen and check all settings. See Section 1 of this manual. Adjust settings if necessary. See Section 1 of this manual for adjustment procedures.
2. Check settings of external limit controls (if any) and adjust if necessary.

Perform start-up and checks

1. Start boiler and perform checks and tests specified in Section 9 - Start-up of the Crest Installation and Operation Manual .

Check flame signal

2. Verify cold fill pressure is correct and that operating pressure does not go too high.
1. At high fire of each combustion system, the flame signal shown on the display should be at least 10 microamps.

Check burner flame

1. Inspect flame through observation windows.
2. A lower flame signal may indicate a fouled or damaged flame sense electrode. If cleaning the flame sense electrodes does not improve, ground wiring is in good condition, and ground continuity is satisfactory, replace the flame sense electrode.
2. If the flame is unsatisfactory at either high fire or low fire, remove and clean the burner. Clean the burner thoroughly using a vacuum cleaner or compressed air. Do not use compressed air to clean the burner if cleaning is performed inside a building.
3. See Section 3 - Troubleshooting in this manual for other procedures to deal with low flame signal.
Page 35 of the Lochinvar 3.5 user manual —  WARNING
Page 35 · click to enlarge
Page 35

2 Maintenance (continued)

Review with owner 1. Review the Crest User’s Information Manual with the owner. 2. Emphasize the need to perform the maintenance schedule specified in the Crest User’s Information Manual (and in this manual as well). 3. Remind the owner of the need to call a licensed contractor should the boiler or system exhibit any unusual behavior. 4. Remind the owner to follow the proper shutdown procedure and to schedule an annual start-up at the beginning of the next heating season.

15. Replace the burner mounting plate assembly and gas/air manifold assembly. Ensure gaskets are in good condition and positioned properly. Restore boiler to operation. 16. Perform start-up and check-out procedures in the Check Flame and Combustion - Section 9 - Startup of the Crest Installation and Operation Manual.

Handling ceramic fiber materials

REMOVAL OF COMBUSTION CHAMBER LINING

WARNING

The combustion chamber insulation in this appliance contains ceramic fiber material. Ceramic fibers can be converted to cristobalite in very high temperature applications. The International Agency for Research on Cancer (IARC) has concluded, “Crystalline silica in the form of quartz or cristobalite from occupational sources is carcinogenic to humans (Group 1).” Normal operating temperatures in this appliance are below the level to convert ceramic fibers to cristobalite. Abnormal operating conditions would have to be created to convert the ceramic fibers in this appliance to cristobalite.

  • Cleaning boiler heat exchanger 1. Shut down boiler:
  • Follow the “To Turn Off Gas to Appliance” instructions for the boiler in Section 9 - Startup.
  • Do not drain the boiler unless it will be exposed to freezing temperatures. If using freeze prevention fluid in system, do not drain. 2. Allow time for the boiler to cool to room temperature if it has been firing. 3. Remove the top access panel to remove the gas/air manifold assembly. 4. Remove the nuts securing the burner to the burner mounting plate. Remove the burner (FIG. 11-2). 5. Remove the nuts securing the burner mounting plate from the heat exchanger and set aside. Remove the entire burner mounting plate assembly.

The ceramic fiber material used in this appliance is an irritant; when handling or replacing the ceramic materials it is advisable that the installer follow these safety guidelines. Avoid breathing dust and contact with skin

The boiler contains ceramic fiber materials. Use care when handling these materials per instructions on this page. Failure to comply could result in severe personal injury.

WARNING

  • and eyes.
  • Use NIOSH certified dust respirator (N95). This type of respirator is based on the OSHA requirements for cristobalite at the time this document was written. Other types of respirators may be needed depending on the job site conditions. Current NIOSH recommendations can be found on the NIOSH website at http:// w w w . c d c . g o v / n i o s h / h o m e p a g e . html. NIOSH approved respirators, manufacturers, and phone numbers are also listed on this website.
  • Wear long-sleeved, loose fitting clothing, gloves, and eye protection. Apply enough water to the combustion

6. Use a vacuum cleaner to remove any accumulation on the tube sheet surfaces. Do not use any solvent. 7. Brush the heat exchanger (tube sheet, combustion chamber walls, and tube entry) while dry using a nylon bristle brush. Caution: DO NOT use a metal brush. Re-vacuum the heat exchanger. 8. Finish cleaning using a clean cloth dampened with warm water. 9. Temporarily remove the condensate drain line from the condensate trap and route directly to a drain. 10. Rinse out debris with a low pressure water supply. The water will drain through the condensate connection. 11. Allow the heat exchanger to thoroughly dry. 12. Reconnect the condensate drain line to the condensate trap. 13. Close isolation valves on piping to isolate boiler from system. Attach a hose to the boiler drain and flush boiler thoroughly with clean water by using purging valves to allow water to flow through the water make-up line to the boiler. 14. When securing the burner, be sure to tighten the nuts, but DO NOT over-tighten. Tighten the nuts to a torque setting of no more than 6.2 ft.-lbs. When securing the burner mounting plate be sure to tighten the nuts, but DO NOT over-tighten. Tighten the nuts to a torque setting of no more than 15.5 ft.-lbs.

chamber lining to prevent airborne dust. Remove the combustion chamber lining

from the boiler and place it in a plastic bag for disposal. Wash potentially contaminated clothes

separately from other clothing. Rinse clothes washer thoroughly.

NIOSH stated First Aid.

Eye: Irrigate immediately. Breathing: Fresh air.

Page 36 of the Lochinvar 3.5 user manual —  WARNING
Page 36 · click to enlarge
Page 36

3 Troubleshooting

Check control module fuses

Label all wires prior to disconnection when servicing controls. Wiring errors can cause improper and dangerous operation. Always disconnect power to the boiler before servicing. Failure to comply could result in severe personal injury, death, or substantial property damage.

WARNING

ALWAYS check control module fuses before replacing control module or any major components (blower, etc.). If one of these fuses is blown, it can prevent the control module or other components from operating.

NOTICE

1. Turn OFF the power to the boiler at the external line switch.

Never jumper (bypass) any device except for momentary testing as outlined in the Troubleshooting chart. Severe personal injury, death, or substantial property damage can result.

2. Remove the upper and lower doors.

WARNING

3. Remove the four (4) screws securing the control panel cover to the unit to gain access to the control module.
4. Inspect fuses F2, F4, and F5, see FIG 3-1 below.

Figure 3-1 Control Module Fuses

Before troubleshooting:

Lochinvar 3.5 — Before troubleshooting: diagram (page 36)
Fig. 26 · Before troubleshooting:
1. Have the following items: a. Voltmeter that can check 120 vac, 24 vac, and 12 vdc. b. Continuity checker. c. Contact thermometer.
2. Check for 120 vac (minimum 102 vac to maximum 132 vac) to boiler.
3. Make sure thermostat is calling for heat and contacts are closed. Check for 24 vac between thermostat wire nuts and ground.
4. Make sure all external limit controls are installed and operating.
5. The boiler is shipped with four (4) spare fuses in a plastic bag located inside the control panel.

Check the following:

1. Wire connectors to control module are securely plugged in at the module and originating control.
6. If necessary, replace open fuse (F2 is 3.15 amps, F4, F5 and F6 are 5 amps each).
2. Gas pressures:
  • Maximum: 14 inches w.c. (3.5 kPa) (natural and LP) with no flow (lockup) or with boiler on
  • Minimum: 4 inches w.c. (1.0 kPa) (natural and LP), with gas flowing (verify during boiler startup)

Do not jumper fuse or replace with any fuse except as specified. Failure to comply could result in severe personal injury, death, or substantial property damage.

WARNING

7. Re-install the control panel cover using the four (4) screws removed in Step 3. Re-install the upper and lower doors after fuse inspection.
8. Restore power to the boiler at the external line switch and verify boiler operation (Section 9 - Start-up in the Crest Installation and Operation Manual) after completing boiler service.
Page 37 of the Lochinvar 3.5 user manual — FAULT CAUSE CORRECTIVE ACTION
Page 37 · click to enlarge
Page 37

3 Troubleshooting (continued)

Table 3A Troubleshooting Chart - No Display

FAULT CAUSE CORRECTIVE ACTION

- No 120 vac supplied to unit. • Check external line switch, fuse, or breaker.

  • Check position of ON/OFF switch. Turn switch to the ON position.
  • Check 120 vac through the ON/OFF switch.
  • Check wiring harness connection between display board and main control board. Connect harness at both points.

- No voltage through the switch. • Replace switch.

- Bad display board. • Replace board.

- Bad main control board. • Replace the main control board.

- Blown fuse. • Replace fuse F2 on the main control board, see page 38 of this manual.

- Main control board temperature set point satisfied.

  • Review temperature setting.

- Remote thermostat satisfied. • Review remote thermostat setting.

- Outside air temperature above Warm Weather Shutdown (WWSD) set point for main control board.

  • Check location of outside air sensor. Check resistance of outdoor air sensor and compare to Table 3C on page 38 of this manual.

- Unit locked out on fault. • Consult display for specific fault. Refer to fault descriptions on page 40 of this manual for corrective actions.

- Ramp delay active. • Check ramp delay parameter settings. Optional PC software required.

Modulate Up to 100%

  • Turn ramp delay feature off. See page 20 of this manual for instructions on how to turn this feature off.

- Boiler controlled by BMS. • Check BMS parameter settings.

Show 4 more labels / short text on this page
No Display · No Burner · Operation · Unit Does Not
Page 38 of the Lochinvar 3.5 user manual — Checking temperature sensors
Page 38 · click to enlarge
Page 38

3 Troubleshooting

Checking temperature sensors

The boiler temperature sensors (inlet water, outlet water, system water, flue, and outdoor air) are all resistance type devices. The following tables show the correct values for the sensors at various temperatures. Use an ohmmeter to read the resistance of the sensor at a known temperature. If the resistance of the sensor does not closely match its corresponding table, replace the sensor

It is important to note that the flue and outlet inlet air - S11/S13 #1 and S12/S14 #2 water sensors have two temperature sensing devices in one housing. These devices are designated as S1/S9, outlet sensor and S3/S10, flue sensor. Please reference the wiring diagram in the Crest Installation and Operation Manual for correct terminal location.

Table 3B - Inlet Water/System Sensor Resistance vs. Temperature

Table 3C - Outdoor Air Sensor Resistance vs. Temperature

Lochinvar 3.5 — Checking temperature sensors diagram (page 38)
Fig. 27 · Checking temperature sensors

-50 490,813 20 46,218 -40 336,606 30 34,558 -30 234,196 40 26,099 -20 165,180 50 19,900 10 118,018 60 15,311 0 85,362 70 11,883 10 62,465 80 9,299

Table 3D - Outlet Water Sensor Resistance vs. Temperature

Lochinvar 3.5 — Checking temperature sensors diagram (page 38)
Fig. 28 · Checking temperature sensors

Pre-Mix Air 1 S11 GY/Y Pre-Mix Air 1 S13 BR/Y

Pre-Mix Air 2 S12 BK/Y Pre-Mix Air 2 S14 T/Y

50 19,553 158 2,004 50 40,030 158 3,478 68 12,690 176 1,464 68 25,030 176 2,492 86 8,406 194 1,084 86 16,090 194 1,816 104 5,715 212 816 104 10,610 212 1,344 122 3,958 122 7,166 140 2,786 140 4,943

Table 3E - Flue Sensor Resistance vs. Temperature

Lochinvar 3.5 — Checking temperature sensors diagram (page 38)
Fig. 29 · Checking temperature sensors

50 40,030 158 3,478 50 258,500 158 16,870 68 25,030 176 2,492 68 125,500 176 12,000 86 16,090 194 1,816 86 80,220 194 8,674 104 10,610 212 1,344 104 52,590 212 6,369 122 7,166 122 35,270 140 4,943 140 24,160

Page 39 of the Lochinvar 3.5 user manual — FAULT CAUSE CORRECTIVE ACTION
Page 39 · click to enlarge
Page 39

3 Troubleshooting (continued)

Table 3F Troubleshooting Chart - Noisy System

FAULT CAUSE CORRECTIVE ACTION

- Supply gas problem. Natural and LP gas pressures should be between 4 inches w.c. (1.0 kPa) and 14 inches w.c. (3.5 kPa).

  • Refer to Section 6 - Gas Connections of the Crest Installation and Operation Manual for detailed information concerning the gas supply.

- Gas/air mixture problem. • Refer to the Gas Valve Adjustment Procedure on page 53 of this manual for the proper gas valve setting. Verify that the vent/air intake lengths do not exceed the maximum listed in the General Venting section of the Crest Installation and Operation Manual.

- Dirty/damaged burner. • Refer to page 34 in this manual for the burner removal and inspection procedure. Clean or replace the burner as necessary.

- Air in the piping system. • Properly purge all air from the piping system.

  • Replace fuse F4 on the control board, see page 36 of this manual.

- Blown fuse.

No Pump Operation - Boiler Pump System Pump

- Faulty pump. • Replace pump.

- Internal fault on control board. • Replace main control board.

- Faulty pump relay. • Replace relay.

  • Reference the Boiler Pump Mode and System Pump Mode parameters in the Service section of this manual.

- Incorrect parameter setting.

- System pressure exceeds relief valve setting.

  • Lower the system pressure below the rating of the supplied relief valve or replace the standard relief valve with a higher rated valve up to the maximum pressure of the heat exchanger 160 psi (40 kPa).
  • Improperly sized expansion tank.
Show 4 more labels / short text on this page
Noisy Operation · or HWG Pump · Relief Valve · Opening
Page 40 of the Lochinvar 3.5 user manual — FAULT DESCRIPTION CORRECTIVE ACTION
Page 40 · click to enlarge
Page 40

3 Troubleshooting

Table 3G Troubleshooting Chart - Fault Messages Displayed on Boiler Interface

FAULT DESCRIPTION CORRECTIVE ACTION

  • Measure the supply gas pressure to determine cause of failure. Natural and LP gas pressures should be between 4 - 14 inches w.c. (1.0 - 3.5 kPa).

Open (will require a manual reset once the condition has been corrected. Press

Either the low gas pressure switch or one of the high gas pressure switches tripped.

  • Refer to Section 6 - Gas Connections of the Crest Installation and Operation Manual for detailed information concerning the gas supply.

the RESET button on the SMART TOUCH display

to reset.)

  • Correct the supply gas pressure if necessary.
  • Reset the LWCO from the RESET button on the front control panel.

Low Water Cutoff Open (will require a manual reset once condition has

  • Verify system is full of water and all air has been purged from the system.

The low water cutoff is not making.

  • Check for loose or misplaced jumpers if flow switch or LWCO is not installed.

been corrected. Press the RESET button on the SMART TOUCH display

to reset.)

Blown fuse. • Replace fuse F2 on the control board, see page 38 of this manual.

  • Check condensate tube from unit to floor drain for proper installation and obstructions.

Open (will require a manual reset once condition has

  • Inspect condensate trap for blockage. Clean if necessary.

The blocked drain switch has detected excessive condensate build up inside the unit.

been corrected. Press the RESET button on the SMART TOUCH display

  • Check for loose wiring connection at wire harness plug.

to reset.)

  • Bad blocked drain switch. Replace switch.
  • Check the wiring connections to switch. Wires should be connected to the common and normally closed terminals.
  • Vent/air intake lengths exceed the maximum allowed lengths. Refer to Section 2 - General Venting of the Crest Installation and Operation Manual for proper lengths.

APS Open (will require a manual reset once the condition has been corrected. Press

  • Check for obstruction or blockage in the vent/air intake pipes or at terminations.

Blocked flue/inlet pressure switch contacts are open.

  • Check reference hose and tubing connected to the pressure switch for blockage or obstruction.

the RESET button on the SMART TOUCH display

  • Inspect the burner. Reference page 34 of this manual for removal and cleaning procedures. Replace if necessary.

to reset.)

  • Inspect the heat exchanger. Reference page 35 of this manual for removal and cleaning procedures. Replace if necessary.
  • Faulty air pressure switch. Replace switch.
  • Verify combustion air blower is operating. Replace if necessary.

Gas Pressure SW · Blocked Drain SW

Page 41 of the Lochinvar 3.5 user manual — FAULT DESCRIPTION CORRECTIVE ACTION
Page 41 · click to enlarge
Page 41

3 Troubleshooting (continued)

Table 3G (continued from previous page) Troubleshooting Chart - Fault Messages Displayed on Boiler Interface

FAULT DESCRIPTION CORRECTIVE ACTION

The main control board has received a call for heat too quickly after the previous call for heat has ended.

  • The control board will release the call for heat after a set time period.
  • The control board will release the call for heat if the outlet temperature drops too quickly.

The unit has failed to prove main burner ignition. It will require a manual reset before attempting to fire again.

  • Inspect spark electrode and associated wiring for damage and connection. Reference page 34 of this manual for removal and cleaning procedures. Replace if necessary.
  • Visually check for presence of a spark from the view port.
  • Check for proper electrical grounding of the unit.
  • Check incoming supply gas pressure. Natural and LP gas pressures should be between 4 - 14 inches w.c. (1.0 - 3.5 kPa). Refer to Section 6 - Gas Connections of the Crest Installation and Operation Manual for detailed information concerning the gas supply.
  • Verify that the plastic hose from gas valve 1 to the air inlet is connected and is not damaged.
  • Verify that the vent/air intake pipes are correctly installed and that there are no obstructions.

Ignition (will require a manual reset once the condition

  • If 120 vac is present at the main control board, check the wiring between the main control board and the gas valve. Replace the wiring if necessary. Do not disconnect the wiring from the gas valve and attempt to measure voltage at that point. The main control board can detect if the gas valve is not connected and will display the Gas Valve / Connection fault.

has been corrected. Press the RESET button on the SMART TOUCH

display to reset.)

  • If 120 vac is present, check the outlet of the valve to ensure the valve is flowing gas. With a manometer connected to the outlet tap of the gas valve, when the unit is in the prepurge period, there should be a negative pressure present. When the valve is energized a change in pressure should occur. If the pressure change does not occur, the gas valve is not opening. Replace the gas valve.
  • Inspect flame sensor and associated wiring. Reference page 34 of this manual for removal and cleaning procedures. Replace if necessary.
  • Inspect the burner. Reference page 34 of this manual for removal and cleaning procedures. Replace if necessary.

Anti-cycling · Flame Failure

Page 42 of the Lochinvar 3.5 user manual — FAULT DESCRIPTION CORRECTIVE ACTION
Page 42 · click to enlarge
Page 42

3 Troubleshooting

Table 3G (continued from previous page) Troubleshooting Chart - Fault Messages Displayed on Boiler Interface

FAULT DESCRIPTION CORRECTIVE ACTION

Sequence 1 (will require a manual reset once the condition

  • Check supply voltage for proper polarity.

The flame detector 1 circuit is seeing a flame signal while no flame is present.

  • Check external wiring for voltage feedback.

has been corrected. Press the RESET button on the SMART TOUCH

  • Check the internal wiring for bad connections.

display to reset.)

  • Check combustion of burner 1 and adjust valve 1 if necessary.

Sequence 2 (will require a manual reset once the condition

  • Check supply voltage for proper polarity.

The flame detector 2 circuit is seeing a flame signal from burner 1.

  • Check external wiring for voltage feedback.

has been corrected. Press the RESET button on the SMART TOUCH

  • Check the flame rod and make sure it is clean.
  • Check internal wiring for bad connections.

display to reset.)

  • Remove and inspect the burner.
  • Inspect flame rod 1 and associated wiring for damage and connection. Reference page 34 of this manual for removal and cleaning procedures. Replace if necessary.
  • Check for proper electrical grounding of unit.
  • Check incoming supply gas pressure. Natural and L.P. gas pressures should be between 4 - 14 inches w.c. (1.0 - 3.5 kPa). Refer to Section 6 - Gas Connections of the Crest Installation and Operation Manual for detailed information concerning the gas supply.

Running 1 (will require a manual reset once the condition

  • Verify that the plastic hose from the gas valve to the air inlet is connected and is not damaged.

The unit was running and lost the flame signal.

has been corrected. Press the RESET button on the SMART TOUCH

  • Verify that the vent/air intake pipes are installed correctly and there are no obstructions.

display to reset.)

  • Inspect flame sensor and associated wiring. Reference page 34 of this manual for removal and cleaning procedures. Replace if necessary.
  • Check combustion.
  • Inspect the burner. Reference page 34 of this manual for removal and cleaning procedures. Replace if necessary.

Flame Out of · Flame Out of · Flame Failure

Page 43 of the Lochinvar 3.5 user manual — FAULT DESCRIPTION CORRECTIVE ACTION
Page 43 · click to enlarge
Page 43

3 Troubleshooting (continued)

Table 3G (continued from previous page) Troubleshooting Chart - Fault Messages Displayed on Boiler Interface

FAULT DESCRIPTION CORRECTIVE ACTION

  • Inspect flame rod 2 and associated wiring for damage and connection. Reference page 34 of this manual for removal and cleaning procedures. Replace if necessary.
  • Check for proper electrical grounding of unit.
  • Check incoming supply gas pressure. Natural and L.P. gas pressures should be between 4 - 14 inches w.c. (1.0 - 3.5 kPa). Refer to Section 6 - Gas Connections of the Crest Installation and Operation Manual for detailed information concerning the gas supply.

Running 2 (will require a manual reset once the condition has been corrected. Press

The unit was running and lost the flame signal.

  • Verify that the plastic hose from the gas valve to the air inlet is connected and is not damaged.

the RESET button on the SMART TOUCH display

  • Verify that the vent/air intake pipes are installed correctly and there are no obstructions.

to reset.)

  • Inspect flame sensor and associated wiring. Reference page 34 of this manual for removal and cleaning procedures. Replace if necessary.
  • Check combustion.
  • Inspect the burner. Reference page 34 of this manual for removal and cleaning procedures. Replace if necessary.

Gas Valve / Relay

Failure 1 (will require a manual reset once the condition has been corrected. Press

  • Check wiring harness connection at the gas valve and at the main control board.

The main control board did not detect gas valve 1.

  • Replace the gas valve wire harness.

the RESET button on the SMART TOUCH display

  • Replace the gas valve.

to reset.)

Gas Valve / Relay

Failure 2 (will require a manual reset once the condition has been corrected. Press

  • Check wiring harness connection at the gas valve and at the main control board.

The main control board did not detect gas valve 2.

  • Replace the gas valve wire harness.

the RESET button on the SMART TOUCH display

  • Replace the gas valve.

to reset.)

Flame Failure

Page 44 of the Lochinvar 3.5 user manual — FAULT DESCRIPTION CORRECTIVE ACTION
Page 44 · click to enlarge
Page 44

3 Troubleshooting

Table 3G (continued from previous page) Troubleshooting Chart - Fault Messages Displayed on Boiler Interface

FAULT DESCRIPTION CORRECTIVE ACTION

  • Verify that the system is full of water and that all air has been properly purged from the system.
  • Verify that the boiler is piped properly into the heating system. Refer to Section 5 - Hydronic Piping of the Crest Installation and Operation Manual for the proper piping methods for the Crest boiler.
  • Check 120 vac to boiler pump motor on a call for heat. If voltage is not present, check wiring back to the main control board.
  • Check the ARHL set point.
  • If 120 vac is present on a call for heat and the boiler pump is not operating, replace the pump.

The outlet water temperature has exceeded the setting of the automatic reset high limit.

  • If the system pump is a variable speed pump, ensure that the system flow is not less than the boiler flow.
  • If operating on something other than an outlet sensor, check temperature setting of the main control board.
  • If the optional manual reset high limit has tripped, check setting of the device.
  • Check resistance of water sensors and compare to Table 3B on page 38 of this manual. Replace sensor if necessary.
  • Replace the main control board.
  • Verify that the system is full of water and that all air has been properly purged from the system.
  • Verify that the boiler is piped properly into the heating system. Refer to Section 5 - Hydronic Piping of the Crest Installation and Operation Manual for the proper piping methods for the Crest boiler.
  • Check voltage to boiler pump motor on a call for heat. If voltage is not present, check wiring back to the main control board.

Manual Reset High Limit Open

  • Replace the pump relay if necessary.
  • If 120 vac is present on a call for heat and the boiler pump is not operating, replace the pump.

(will require a manual reset once the condition has been corrected. Press

The outlet water temperature has exceeded the setting of the high limit.

  • If the system pump is a variable speed pump, ensure that the system flow is not less than the boiler flow.

the RESET button on the SMART TOUCH display

  • If operating on either an inlet or system supply sensor, check temperature setting of the main control board.

to reset.)

  • If the high limit has tripped, check setting of the device and the MRHL set point.
  • Check resistance of water sensors and compare to Table 3B on page 38 of this manual. Replace sensor if necessary.
  • Replace high limit (if equipped).
  • Replace main control board.

Auto Reset · High Limit

Page 45 of the Lochinvar 3.5 user manual — FAULT DESCRIPTION CORRECTIVE ACTION
Page 45 · click to enlarge
Page 45

3 Troubleshooting (continued)

Table 3G (continued from previous page) Troubleshooting Chart - Fault Messages Displayed on Boiler Interface

FAULT DESCRIPTION CORRECTIVE ACTION

  • Vent/air intake lengths exceed the maximum allowed lengths. Refer to Section 2 - General Venting of the Crest Installation and Operation Manual for proper lengths.

Fan Speed Low 1

(will require a manual reset once the condition has been corrected. Press

The actual fan 1 RPM is 30% lower than what is being called for.

  • Check for obstruction or blockage in the vent/air intake pipes or at terminations.
  • Check the wiring connections at fan 1 and at the main control board.

the RESET button on the SMART TOUCH display

  • Replace the fan.

to reset.)

Blown fuse. • Replace fuse F2 on the control board, see page 36 of this manual.

  • Vent/air intake lengths exceed the maximum allowed lengths. Refer to Section 2 - General Venting of the Crest Installation and Operation Manual for proper lengths.

Fan Speed Low 2

(will require a manual reset once the condition has been corrected. Press

The actual fan 2 RPM is 30% lower than what is being called for.

  • Check for obstruction or blockage in the vent/air intake pipes or at terminations.
  • Check the wiring connections at fan 2 and at the main control board.

the RESET button on the SMART TOUCH display

to reset.)

  • Replace the fan.

Blown fuse. • Replace fuse F2 on the control board, see page 36 of this manual.

  • Vent/air intake lengths exceed the maximum allowed lengths. Refer to Section 2 - General Venting of the Crest Installation and Operation Manual for proper lengths.

Fan Speed High 1

(will require a manual reset once the condition has been corrected. Press

The actual fan 1 RPM is 30% higher than what is being called for.

  • Check for obstruction or blockage in the vent/air intake pipes or at terminations.

the RESET button on the SMART TOUCH display

  • Check the wiring connections at the fan and at the main control board.

to reset.)

  • Replace the fan.
  • Vent/air intake lengths exceed the maximum allowed lengths. Refer to Section 2 - General Venting of the Crest Installation and Operation Manual for proper lengths.

Fan Speed High 2

(will require a manual reset once the condition has been corrected. Press

  • Check for obstruction or blockage in the vent/air intake pipes or at terminations.

The actual fan 2 RPM is 30% higher than what is being called for.

the RESET button on the SMART TOUCH display

  • Check the wiring connections at the fan and at the main control board.

to reset.)

  • Replace the fan.
Page 46 of the Lochinvar 3.5 user manual — FAULT DESCRIPTION CORRECTIVE ACTION
Page 46 · click to enlarge
Page 46

3 Troubleshooting

Table 3G (continued from previous page) Troubleshooting Chart - Fault Messages Displayed on Boiler Interface

FAULT DESCRIPTION CORRECTIVE ACTION

Sw Open (will require a manual reset once the condition has been corrected. Press

  • Check function of remote devices.

An optional remote proving switch is not making.

  • Check for loose or misplaced jumper if proving switch is not installed.

the RESET button on the SMART TOUCH display

to reset.)

  • Inspect the heat exchanger. Reference page 35 of this manual for the procedure on how to clean the flue side of the heat exchanger.
  • Inspect the flue sensor and associated wiring. Measure the resistance of the flue sensor and compare to Table 3E on page 38 of this manual. Replace the sensor if necessary.

The stack temperature has exceeded the set parameters for the boiler.

  • Verify that the vent/air intake pipes are properly installed and that there are no obstructions.
  • Verify that the system is full of water and that all air has been properly purged from the system.
  • Verify that the boiler is piped properly into the heating system. Refer to Section 5 - Hydronic Piping of the Crest Installation and Operation Manual for the proper piping methods for the Crest boiler.
  • Check for 120 vac to the boiler pump motor on a call for heat. If voltage is not present, check the wiring back to the main control board. Replace the main control board if necessary.

Delta T High The temperature rise across the heat exchanger has exceeded the set parameters for the boiler.

  • If 120 vac is present on a call for heat and the boiler pump is not operating, replace the pump.
  • Verify that the boiler pump is set to the proper speed or that the pump is the proper size. Reference Section 5 - Hydronic Piping of the Crest Installation and Operation Manual for boiler pump specifications.
  • Inspect the inlet and outlet sensors and associated wiring. Measure the resistance of the sensors and compare to the tables on page 38 of this manual.
  • Verify that the system is full of water and that all air has been properly purged from the system.
  • Verify that the boiler is piped properly into the heating system. Refer to Section 5 - Hydronic Piping of the Crest Installation and Operation Manual for the proper piping methods for the Crest boiler.

High Outlet water temperature has exceeded the maximum outlet water temperature.

  • Check for 120 vac to the boiler pump motor on a call for heat. If voltage is not present, check wiring back to the main control board. Replace the main control board if necessary.
  • If 120 vac is present on a call for heat and the boiler pump is not operating, replace the pump.

Louver Proving · Flue Temp High · Outlet Temp

Page 47 of the Lochinvar 3.5 user manual — FAULT DESCRIPTION CORRECTIVE ACTION
Page 47 · click to enlarge
Page 47

3 Troubleshooting (continued)

Table 3G (continued from previous page) Troubleshooting Chart - Fault Messages Displayed on Boiler Interface

FAULT DESCRIPTION CORRECTIVE ACTION

  • Verify that the boiler pump is set to the proper speed or that the boiler pump is the proper size. Reference Section 5 - Hydronic Piping of the Knight Boiler Installation and Operation Manual for boiler pump specifications.

Outlet water temperature has exceeded the maximum outlet water temperature.

  • Inspect the outlet sensors and associated wiring. Measure the resistance of the sensors and compare to the tables on page 38 of this manual.
  • Check set point of the external control.
  • Check the wiring between the external control and the unit.

Rem Ctrl Flt External control is cycling too often.

  • Replace the control.

Saved (will require a manual reset once the condition has been corrected. Press

  • Press the RESET button on the SMART TOUCH display panel.

After downloading parameters from a laptop, the main control board must be reset.

the RESET button on the SMART TOUCH display

to reset.)

While the unit is in Service Mode, the outlet temperature has exceeded 185°F.

  • Establish a heating load to remove the heat from the boiler loop.
  • Verify that the system is full of water and that all air has been properly purged from the system.
  • Verify that the boiler is piped properly into the heating system. Refer to Section 5 - Hydronic Piping of the Crest Installation and Operation Manual for the proper piping methods for the Crest boiler.
  • Check 120 vac to the boiler pump motor on a call for heat. If voltage is not present, check the wiring back to the main control board. Replace the main control board if necessary.
  • If 120 vac is present on a call for heat and the boiler pump is not operating, replace the pump.
  • Verify that the boiler pump is set to the proper speed or that the boiler pump is the proper size. Reference Section 5 - Hydronic Piping of the Crest Installation and Operation Manual for boiler pump specifications.
Show 4 more labels / short text on this page
Outlet Temp · High (continued) · Parameters · Service Blk
Page 48 of the Lochinvar 3.5 user manual — FAULT DESCRIPTION CORRECTIVE ACTION
Page 48 · click to enlarge
Page 48

3 Troubleshooting

Table 3G (continued from previous page) Troubleshooting Chart - Fault Messages Displayed on Boiler Interface

FAULT DESCRIPTION CORRECTIVE ACTION

Sensor Open (will require a manual reset once the condition has been corrected. Press

  • Check the sensors and their associated wiring. Repair or replace the sensor or wiring if damaged.
  • Measure the resistance of the sensors and compare the resistance to the tables on page 38 of this manual.
  • Replace the sensor if necessary.

Either the inlet water or outlet water temperature sensor has been disconnected.

the RESET button on the

display to reset.)

  • Check the sensors and their associated wiring. Repair or replace the sensor or wiring if damaged.

(will require a manual reset once the condition has been corrected. Press

Either the inlet water or outlet water temperature sensor has been shorted.

  • Measure the resistance of the sensors and compare the resistance to the tables on page 38 of this manual.

the RESET button on the

display to reset.)

  • Replace the sensor if necessary.
  • Check the sensor and its associated wiring. Repair or replace the sensor or wiring if damaged.

Open (will require a manual reset once the condition has been corrected. Press

  • Measure the resistance of the sensors and compare the resistance to the tables on page 38 of this manual.

The flue sensor has been disconnected or removed from the flue.

the RESET button on the

  • Replace the sensor in flue.

display to reset.)

  • Replace the sensor if necessary.
  • Check the sensor and its associated wiring. Repair or replace the sensor or wiring if damaged.

Shorted (will require a manual reset once the condition has been corrected. Press

  • Measure the resistance of the sensors and compare the resistance to the tables on page 38 of this manual.

The flue sensor has been shorted.

the RESET button on the

display to reset.)

  • Replace the sensor if necessary.

Sensors equipped with an internal limit (such as the Lochinvar Squire® Indirect Tank), the limit has opened due to temperature (195°F) or the sensor has become disconnected.

  • Check the tank temperature.
  • Repair or replace the sensor wiring if damaged.
  • Replace the sensor if necessary.
  • Check the wiring connections to switch. Wires should be connected to the common and normally open terminals.
  • Remove switch and check for blockage in the orifice.
  • Vent/air intake lengths exceed the maximum allowed lengths. Refer to Section 2 - General Venting of the Crest Installation and Operation Manual for proper lengths.

Switch Open 1 (will require a manual reset once the condition has been corrected. Press

  • Check for obstruction or blockage in the vent/air intake pipes or at terminations.

Blower proving pressure switch 1 contacts are open.

  • Inspect the burner. Reference page 34 of this manual for removal and cleaning procedures. Replace if necessary.

the RESET button on the

display to reset.)

  • Verify combustion air blower 1 is operating. Replace if necessary.
  • Inspect the heat exchanger. Reference page 35 of this manual for removal and cleaning procedures.
  • Faulty pressure switch. Replace switch.
Show 5 more labels / short text on this page
Sensor Shorted · Flue Sensor · Flue Sensor · Tank Open · Blower Proving
Page 49 of the Lochinvar 3.5 user manual — FAULT DESCRIPTION CORRECTIVE ACTION
Page 49 · click to enlarge
Page 49

3 Troubleshooting (continued)

Table 3G (continued from previous page) Troubleshooting Chart - Fault Messages Displayed on Boiler Interface

FAULT DESCRIPTION CORRECTIVE ACTION

  • Check the wiring connections to switch. Wires should be connected to the common and normally open terminals.
  • Remove switch and check for blockage in the orifice.
  • Vent/air intake lengths exceed the maximum allowed lengths. Refer to Section 2 - General Venting of the Crest Installation and Operation Manual for proper lengths.

Switch Open 2 (will require a manual reset once the condition has been corrected. Press

  • Check for obstruction or blockage in the vent/air intake pipes or at terminations.

Pressure switch contacts are open.

  • Inspect the burner. Reference page 34 of this manual for removal and cleaning procedures. Replace if necessary.

the RESET button on the

display to reset.)

  • Verify combustion air blower 2 is operating. Replace if necessary.
  • Inspect the heat exchanger. Reference page 35 of this manual for removal and cleaning procedures.
  • Faulty pressure switch. Replace switch.
  • Inspect the combustion air temperature sensor and associated wiring.

Differential (will require a manual reset once the condition has been corrected. Press

Combustion air to burner 1 temperature is higher than combustion air to burner 2 temperature or vice versa.

  • Measure the resistance of the combustion air temperature sensor and compare to Table 3E on page 38 of this manual
  • Replace the sensor if necessary.

the RESET button on the

  • Verify that the vent / air intake pipes are properly installed and that there are no obstructions.

display to reset.)

  • Check if the vent backflow preventer is installed for boilers commonly vented.
  • Check if the vent backflow preventer is stuck open while the unit is off.

High 1 (will require a manual reset once the condition has been corrected. Press

  • Inspect the combustion air temperature sensor and associated wiring.

Combustion air temperature is very high.

  • Measure the resistance of the combustion air temperature sensor and compare to Table 3E on page 38 of this manual.

the RESET button on the

display to reset.)

  • Replace the sensor if necessary.
  • Check if the vent backflow preventer is installed for boilers commonly vented.
  • Check if the vent backflow preventer is stuck open while the unit is off.

High 2 (will require a manual reset once the condition has been corrected. Press

  • Inspect the combustion air temperature sensor and associated wiring.

Combustion air temperature is very high.

  • Measure the resistance of the combustion air temperature sensor and compare to Table 3E on page 38 of this manual.

the RESET button on the

display to reset.)

  • Replace the sensor if necessary.
Show 7 more labels / short text on this page
Blower Proving · Burner Supply · Temperature · Burner Supply · Temperature · Burner Supply · Temperature
Page 50 of the Lochinvar 3.5 user manual — FAULT DESCRIPTION CORRECTIVE ACTION
Page 50 · click to enlarge
Page 50

3 Troubleshooting

Table 3G (continued from previous page) Troubleshooting Chart - Fault Messages Displayed on Boiler Interface

FAULT DESCRIPTION CORRECTIVE ACTION

  • Wait 15 minutes and try again.

Too Many Resets - Try Later

Too many manual resets have occurred during a 15 minute period.

  • Turn power off to unit, wait 30 seconds and then turn power back on.

The main control board has detected an internal fault. • Replace the main control board.

The main control board has detected an internal fault. • Replace the main control board.

  • Inspect the heat exchanger. Reference page 35 of this manual for the procedure on how to clean the flue side of the heat exchanger.
  • Inspect the flue sensor and associated wiring. Measure the resistance of the flue sensor and compare to Table 3E on page 38 of this manual. Replace the sensor if necessary.

Shutdown The stack temperature has exceeded the set parameters for the boiler.

  • Verify that the vent/air intake pipes are properly installed and that there are no obstructions.
  • Replace the main control board.
  • Verify that the system is full of water and that all air has been properly purged from the system.
  • Verify that the boiler is piped properly into the heating system. Refer to Section 5 - Hydronic Piping of the Crest Installation and Operation Manual for the proper piping methods for the Crest boiler.
  • Check for voltage to the boiler pump motor on a call for heat. If voltage is not present, check the wiring back to the pump relay. Replace the pump relay if necessary.

The temperature rise across the heat exchanger has exceeded the set parameters for the boiler.

  • If 120 VAC is present on a call for heat and the boiler pump is not operating, replace the pump.
  • Verify that the boiler pump is set to the proper speed or that the pump is the proper size. Reference Section 5 - Hydronic Piping of the Crest Installation and Operation Manual for boiler pump specifications.
Show 5 more labels / short text on this page
Internal Fault · Writing to · Memos · Flue Temp · Delta T Shutdown
Page 51 of the Lochinvar 3.5 user manual — FAULT DESCRIPTION CORRECTIVE ACTION
Page 51 · click to enlarge
Page 51

3 Troubleshooting (continued)

Table 3G (continued from previous page) Troubleshooting Chart - Fault Messages Displayed on Boiler Interface

FAULT DESCRIPTION CORRECTIVE ACTION

  • Verify that the system is full of water and that all air has been properly purged from the system.
  • Verify that the boiler is piped properly into the heating system. Refer to Section 5 - Hydronic Piping of the Crest Installation and Operation Manual for the proper piping methods for the Crest boiler.

Shutdown Outlet water temperature has exceeded the maximum outlet water temperature.

  • Check for voltage to the boiler pump motor on a call for heat. If voltage is not present, check wiring back to the pump relay. Replace the pump relay if necessary.
  • If 120 VAC is present on a call for heat and the boiler pump is not operating, replace the pump.

Watch Dog Error The main control board has detected an internal fault. • Replace the main control board.

Write EEProm The main control board has detected an internal fault. • Replace the main control board.

CRC Parameters The main control board has detected an internal fault. • Replace the main control board.

No Error Stored The main control board has detected an internal fault.

  • Press the RESET button on the SMART TOUCH display panel.

Outlet Temp

Page 52 of the Lochinvar 3.5 user manual — POSSIBLE CAUSE CORRECTIVE ACTION
Page 52 · click to enlarge
Page 52

3 Troubleshooting

Combustion Analysis Procedure

Table 3I Flue Products

1. Turn the main power off to the boiler by placing the “On/Off” switch in the OFF position.

CO 2 O 2 CO 2 O 2

2. Remove the flue temperature sensor from the flue collector. Note: Combustion measurements will be made at this point.
1. High 3.5% - 5.5% 11.2% - 14.8% 5.1% - 6.8% 10.5% - 13.2%
2. High 7.8% - 8.6% 5.6% - 7.1% 9.4% - 11.0% 4.1% - 6.6%
3. Turn the main power on to the boiler by placing the “On/Off” switch in the ON position.
8. After Gas Valve 1 is set, repeat the same procedure for the second gas train by selecting Set Gas Valve 2 - High on the Service Screen.
4. Navigate to the Service Screen from the Home Screen by pressing the MAIN MENU button and then the SERVICE button.
9. Once the heater analysis is complete, test the safety shutoff device by turning the manual shutoff valve to the OFF position and ensuring that the heater shuts down and registers an alarm. Open the manual shutoff valve and reset the control.
5. On the Service Screen place heater into Service Mode by selecting the START button, then selecting Set Gas Valve 1 - High .
10. Turn the main power off to the boiler and replace the flue temperature sensor into the flue pipe connection.
6. Insert the probe from a combustion analyzer into the hole left by the removal of the flue temperature sensor.
11. Place the boiler back into normal operation.
7. Once the heat exchanger has modulated up to rate, measure the combustion. The values should be in the range listed in Table 3I. CO levels should be less than 200 ppm for a properly installed unit. If the combustion is not within range reference the Troubleshooting Chart below for possible causes and corrective actions.

You must replace the flue gas temperature sensor to prevent flue gas spillage into the room. Failure to comply could result in severe personal injury, death, or substantial property damage.

WARNING

Table 3H Troubleshooting Chart - Combustion Levels

POSSIBLE CAUSE CORRECTIVE ACTION

  • Refer to Section 2 - General Venting of the Crest Installation and Operation Manual for the proper venting and air intake methods for the Crest boiler.
  • Check for obstructions at the vent/air intake terminals.

Gas Supply Pressure • Refer to Section 6 - Gas Connections of the Crest Installation and Operation Manual for the proper gas supply for the Crest boiler.

  • Refer to page 34 of this manual for burner removal and cleaning procedures.
  • Replace burner if necessary.

Gas Valve Adjustment • Refer to page 53 of this manual for the gas valve adjustment procedure.

Show 5 more labels / short text on this page
Natural Gas Propane · Gas Valve · Vent/Air Intake Length · or Obstruction · Dirty/Damaged Burner
Page 53 of the Lochinvar 3.5 user manual — Gas valve adjustment procedure
Page 53 · click to enlarge
Page 53

3 Troubleshooting (continued)

Gas valve adjustment procedure

Figure 3-3 Gas Valve AdjustmentModel 2.5
Lochinvar 3.5 — Gas valve adjustment procedure diagram (page 53)
Fig. 30 · Gas valve adjustment procedure

Locate the throttle adjustment screw on the gas valve. For Models 1.5 and 2.0 see FIG. 3-2, for Model 2.5 see FIG. 3-3 and for Models 3.0 and 3.5 see FIG. 3-4. Using a screwdriver, turn the screw a 1/4 turn counterclockwise to increase CO2 levels or a 1/4 turn clockwise to decrease CO2 levels. After one adjustment on the valve, follow the Combustion Analysis Procedure on page 52 of this manual to measure the combustion.

If combustion is still not within the specified range, repeat the procedure. This procedure SHOULD NOT be performed more than four (4) times. If after four (4) adjustments and the combustion is still not within the specified range, revisit the possible causes in Table 3H on page 52 or replace the gas valve.

Lochinvar 3.5 — Gas valve adjustment procedure diagram (page 53)
Fig. 31 · Gas valve adjustment procedure
Figure 3-4 Gas Valve AdjustmentModels 3.0 and 3.5
Figure 3-2 Gas Valve AdjustmentModels 1.5 and 2.0
Page 54 of the Lochinvar 3.5 user manual — 3 Troubleshooting
Page 54 · click to enlarge
Page 54

3 Troubleshooting

NOTES

Page 55 of the Lochinvar 3.5 user manual — NOTES
Page 55 · click to enlarge
Page 55

NOTES

Page 56 of the Lochinvar 3.5 user manual — Combustion Analysis Procedure
Page 56 · click to enlarge
Page 56

Revision Notes: Revision A (ECO #C08179) initial release.

Revision B (ECO C08436) reflects changes made to the parameter table, notice added to the parameter descriptions, changed out the screens on FIG.’s 1-8 and 1-14.

FB-SER Rev B · 7/11

Display codes

Error codes

What the fault codes shown on the display mean and how to clear them.

CodeMeaningFix
F23.15 AMP p.36
Fix-it

Troubleshooting

Common problems, likely causes, and what to do.

ProblemPossible causeRemedy
No Display- No 120 vac supplied to unit.• Check external line switch, fuse, or breaker. • Check position of ON/OFF switch. Turn switch to the ON position. • Check 120 vac through the ON/OFF switch. • Check wiring harness connection between display board and main control board. Connect harness at both points. p.37
No Display- No voltage through the switch.• Replace switch. p.37
No Display- Bad display board.• Replace board. p.37
No Display- Bad main control board.• Replace the main control board. p.37
No Display- Blown fuse.• Replace fuse F2 on the main control board, see page 38 of this manual. p.37
No Burner Operation- Main control board temperature set point satisfied.• Review temperature setting. p.37
No Burner Operation- Remote thermostat satisfied.• Review remote thermostat setting. p.37
No Burner Operation- Outside air temperature above Warm Weather Shutdown (WWSD) set point for main control board.• Check location of outside air sensor. Check resistance of outdoor air sensor and compare to Table 3C on page 38 of this manual. p.37
No Burner Operation- Unit locked out on fault.• Consult display for specific fault. Refer to fault descriptions on page 40 of this manual for corrective actions. p.37
Unit Does Not Modulate Up to 100%- Ramp delay active.• Check ramp delay parameter settings. Optional PC software required. p.37
Unit Does Not Modulate Up to 100%• Turn ramp delay feature off. See page 20 of this manual for instructions on how to turn this feature off. p.37
Unit Does Not Modulate Up to 100%- Boiler controlled by BMS.• Check BMS parameter settings. p.37
Noisy Operation- Supply gas problem. Natural and LP gas pressures should be between 4 inches w.c. (1.0 kPa) and 14 inches w.c. (3.5 kPa).• Refer to Section 6 - Gas Connections of the Crest Installation and Operation Manual for detailed information concerning the gas supply. p.39
Noisy Operation- Gas/air mixture problem.• Refer to the Gas Valve Adjustment Procedure on page 53 of this manual for the proper gas valve setting. Verify that the vent/air intake lengths do not exceed the maximum listed in the General Venting section of the Crest Installation and Operation Manual. p.39
Noisy Operation- Dirty/damaged burner.• Refer to page 34 in this manual for the burner removal and inspection procedure. Clean or replace the burner as necessary. p.39
Noisy Operation- Air in the piping system.• Properly purge all air from the piping system. p.39
No Pump Operation - Boiler Pump System Pump or HWG Pump- Blown fuse.• Replace fuse F4 on the control board, see page 36 of this manual. p.39
No Pump Operation - Boiler Pump System Pump or HWG Pump- Faulty pump.• Replace pump. p.39
No Pump Operation - Boiler Pump System Pump or HWG Pump- Internal fault on control board.• Replace main control board. p.39
No Pump Operation - Boiler Pump System Pump or HWG Pump- Faulty pump relay.• Replace relay. p.39
No Pump Operation - Boiler Pump System Pump or HWG Pump- Incorrect parameter setting.• Reference the Boiler Pump Mode and System Pump Mode parameters in the Service section of this manual. p.39
Relief Valve Opening-System pressure exceeds relief valve setting.• Lower the system pressure below the rating of the supplied relief valve or replace the standard relief valve with a higher rated valve up to the maximum pressure of the heat exchanger 160 psi (40 kPa). • Improperly sized expansion tank. p.39
Gas Pressure SW Open (will require a manual reset once the condition has been corrected. Press the RESET button on the SMART TOUCH display to reset.)• Measure the supply gas pressure to determine cause of failure. Natural and LP gas pressures should be between 4 - 14 inches w.c. (1.0 - 3.5 kPa). • Refer to Section 6 - Gas Connections of the Crest Installation and Operation Manual for detailed information concerning the gas supply. • Correct the supply gas pressure if necessary. p.40
Low Water Cutoff Open (will require a manual reset once condition has been corrected. Press the RESET button on the SMART TOUCH display to reset.)• Reset the LWCO from the RESET button on the front control panel. • Verify system is full of water and all air has been purged from the system. • Check for loose or misplaced jumpers if flow switch or LWCO is not installed. p.40
Low Water Cutoff Open (will require a manual reset once condition has been corrected. Press the RESET button on the SMART TOUCH display to reset.)• Replace fuse F2 on the control board, see page 38 of this manual. p.40
Blocked Drain SW Open (will require a manual reset once condition has been corrected. Press the RESET button on the SMART TOUCH display to reset.)• Check condensate tube from unit to floor drain for proper installation and obstructions. • Inspect condensate trap for blockage. Clean if necessary. • Check for loose wiring connection at wire harness plug. • Bad blocked drain switch. Replace switch. p.40
APS Open (will require a manual reset once the condition has been corrected. Press the RESET button on the SMART TOUCH display to reset.)• Check the wiring connections to switch. Wires should be connected to the common and normally closed terminals. • Vent/air intake lengths exceed the maximum allowed lengths. Refer to Section 2 - General Venting of the Crest Installation and Operation Manual for proper lengths. • Check for obstruction or blockage in the vent/air intake pipes or at terminations. • Check reference hose and tubing connected to the pressure switch for blockage or obstruction. • Inspect the burner. Reference page 34 of this manual for removal and cleaning procedures. Replace if necessary. • Inspect the heat exchanger. Reference page 35 of this manual for removal and cleaning procedures. Replace if necessary. • Faulty air pressure switch. Replace switch. • Verify combustion air blower is operating. Replace if necessary. p.40
Anti-cycling• The control board will release the call for heat after a set time period. • The control board will release the call for heat if the outlet temperature drops too quickly. p.41
Flame Failure Ignition (will require a manual reset once the condition has been corrected. Press the RESET button on the SMART TOUCH display to reset.)• Inspect spark electrode and associated wiring for damage and connection. Reference page 34 of this manual for removal and cleaning procedures. Replace if necessary. • Visually check for presence of a spark from the view port. • Check for proper electrical grounding of the unit. • Check incoming supply gas pressure. Natural and LP gas pressures should be between 4 - 14 inches w.c. (1.0 - 3.5 kPa). Refer to Section 6 - Gas Connections of the Crest Installation and Operation Manual for detailed information concerning the gas supply. • Verify that the plastic hose from gas valve 1 to the air inlet is connected and is not damaged. • Verify that the vent/air intake pipes are correctly installed and that there are no obstructions. • If 120 vac is present at the main control board, check the wiring between the main control board and the gas valve. Replace the wiring if necessary. Do not disconnect the wiring from the gas valve and attempt to measure voltage at that point. The main control board can detect if the gas valve is not connected and will display the Gas Valve / Connection fault. • If 120 vac is present, check the outlet of the valve to ensure the valve is flowing gas. With a manometer connected to the outlet tap of the gas valve, when the unit is in the prepurge period, there should be a negative pressure present. When the valve is energized a change in pressure should occur. If the pressure change does not occur, the gas valve is not opening. Replace the gas valve. • Inspect flame sensor and associated wiring. Reference page 34 of this manual for removal and cleaning procedures. Replace if necessary. • Inspect the burner. Reference page 34 of this manual for removal and cleaning procedures. Replace if necessary. p.41
Flame Out of Sequence 1 (will require a manual reset once the condition has been corrected. Press the RESET button on the SMART TOUCH display to reset.)• Check supply voltage for proper polarity. • Check external wiring for voltage feedback. • Check the internal wiring for bad connections. p.42
Flame Out of Sequence 2 (will require a manual reset once the condition has been corrected. Press the RESET button on the SMART TOUCH display to reset.)• Check combustion of burner 1 and adjust valve 1 if necessary. • Check supply voltage for proper polarity. • Check external wiring for voltage feedback. • Check the flame rod and make sure it is clean. • Check internal wiring for bad connections. • Remove and inspect the burner. p.42
Flame Failure Running 1 (will require a manual reset once the condition has been corrected. Press the RESET button on the SMART TOUCH display to reset.)• Inspect flame rod 1 and associated wiring for damage and connection. Reference page 34 of this manual for removal and cleaning procedures. Replace if necessary. • Check for proper electrical grounding of unit. • Check incoming supply gas pressure. Natural and L.P. gas pressures should be between 4 - 14 inches w.c. (1.0 - 3.5 kPa). Refer to Section 6 - Gas Connections of the Crest Installation and Operation Manual for detailed information concerning the gas supply. • Verify that the plastic hose from the gas valve to the air inlet is connected and is not damaged. • Verify that the vent/air intake pipes are installed correctly and there are no obstructions. • Inspect flame sensor and associated wiring. Reference page 34 of this manual for removal and cleaning procedures. Replace if necessary. • Check combustion. • Inspect the burner. Reference page 34 of this manual for removal and cleaning procedures. Replace if necessary. p.42
Flame Failure Running 2 (will require a manual reset once the condition has been corrected. Press the RESET button on the SMART TOUCH display to reset.)• Inspect flame rod 2 and associated wiring for damage and connection. Reference page 34 of this manual for removal and cleaning procedures. Replace if necessary. • Check for proper electrical grounding of unit. • Check incoming supply gas pressure. Natural and L.P. gas pressures should be between 4 - 14 inches w.c. (1.0 - 3.5 kPa). Refer to Section 6 - Gas Connections of the Crest Installation and Operation Manual for detailed information concerning the gas supply. • Verify that the plastic hose from the gas valve to the air inlet is connected and is not damaged. • Verify that the vent/air intake pipes are installed correctly and there are no obstructions. • Inspect flame sensor and associated wiring. Reference page 34 of this manual for removal and cleaning procedures. Replace if necessary. • Check combustion. • Inspect the burner. Reference page 34 of this manual for removal and cleaning procedures. Replace if necessary. p.43
Gas Valve / Relay Failure 1 (will require a manual reset once the condition has been corrected. Press the RESET button on the SMART TOUCH display to reset.)• Check wiring harness connection at the gas valve and at the main control board. • Replace the gas valve wire harness. • Replace the gas valve. p.43
Gas Valve / Relay Failure 2 (will require a manual reset once the condition has been corrected. Press the RESET button on the SMART TOUCH display to reset.)• Check wiring harness connection at the gas valve and at the main control board. • Replace the gas valve wire harness. • Replace the gas valve. p.43
Auto Reset High Limit• Verify that the system is full of water and that all air has been properly purged from the system. • Verify that the boiler is piped properly into the heating system. Refer to Section 5 - Hydronic Piping of the Crest Installation and Operation Manual for the proper piping methods for the Crest boiler. • Check 120 vac to boiler pump motor on a call for heat. If voltage is not present, check wiring back to the main control board. • Check the ARHL set point. • If 120 vac is present on a call for heat and the boiler pump is not operating, replace the pump. • If the system pump is a variable speed pump, ensure that the system flow is not less than the boiler flow. • If operating on something other than an outlet sensor, check temperature setting of the main control board. • If the optional manual reset high limit has tripped, check setting of the device. • Check resistance of water sensors and compare to Table 3B on page 38 of this manual. Replace sensor if necessary. • Replace the main control board. p.44
Manual Reset High Limit Open (will require a manual reset once the condition has been corrected. Press the RESET button on the SMART TOUCH display to reset.)• Verify that the system is full of water and that all air has been properly purged from the system. • Verify that the boiler is piped properly into the heating system. Refer to Section 5 - Hydronic Piping of the Crest Installation and Operation Manual for the proper piping methods for the Crest boiler. • Check voltage to boiler pump motor on a call for heat. If voltage is not present, check wiring back to the main control board. • Replace the pump relay if necessary. • If 120 vac is present on a call for heat and the boiler pump is not operating, replace the pump. • If the system pump is a variable speed pump, ensure that the system flow is not less than the boiler flow. • If operating on either an inlet or system supply sensor, check temperature setting of the main control board. • If the high limit has tripped, check setting of the device and the MRHL set point. • Check resistance of water sensors and compare to Table 3B on page 38 of this manual. Replace sensor if necessary. • Replace high limit (if equipped). • Replace main control board. p.44
Fan Speed Low 1 (will require a manual reset once the condition has been corrected. Press the RESET button on the SMART TOUCH display to reset.)• Vent/air intake lengths exceed the maximum allowed lengths. Refer to Section 2 - General Venting of the Crest Installation and Operation Manual for proper lengths. • Check for obstruction or blockage in the vent/air intake pipes or at terminations. • Check the wiring connections at fan 1 and at the main control board. • Replace the fan. p.45
Fan Speed Low 1 (will require a manual reset once the condition has been corrected. Press the RESET button on the SMART TOUCH display to reset.)• Replace fuse F2 on the control board, see page 36 of this manual. p.45
Fan Speed Low 2 (will require a manual reset once the condition has been corrected. Press the RESET button on the SMART TOUCH display to reset.)• Vent/air intake lengths exceed the maximum allowed lengths. Refer to Section 2 - General Venting of the Crest Installation and Operation Manual for proper lengths. • Check for obstruction or blockage in the vent/air intake pipes or at terminations. • Check the wiring connections at fan 2 and at the main control board. • Replace the fan. p.45
Fan Speed Low 2 (will require a manual reset once the condition has been corrected. Press the RESET button on the SMART TOUCH display to reset.)• Replace fuse F2 on the control board, see page 36 of this manual. p.45
Fan Speed High 1 (will require a manual reset once the condition has been corrected. Press the RESET button on the SMART TOUCH display to reset.)• Vent/air intake lengths exceed the maximum allowed lengths. Refer to Section 2 - General Venting of the Crest Installation and Operation Manual for proper lengths. • Check for obstruction or blockage in the vent/air intake pipes or at terminations. • Check the wiring connections at the fan and at the main control board. • Replace the fan. p.45
Fan Speed High 2 (will require a manual reset once the condition has been corrected. Press the RESET button on the SMART TOUCH display to reset.)• Vent/air intake lengths exceed the maximum allowed lengths. Refer to Section 2 - General Venting of the Crest Installation and Operation Manual for proper lengths. • Check for obstruction or blockage in the vent/air intake pipes or at terminations. • Check the wiring connections at the fan and at the main control board. • Replace the fan. p.45
Louver Proving Sw Open (will require a manual reset once the condition has been corrected. Press the RESET button on the SMART TOUCH display to reset.)• Check function of remote devices. • Check for loose or misplaced jumper if proving switch is not installed. p.46
Flue Temp High• Inspect the heat exchanger. Reference page 35 of this manual for the procedure on how to clean the flue side of the heat exchanger. • Inspect the flue sensor and associated wiring. Measure the resistance of the flue sensor and compare to Table 3E on page 38 of this manual. Replace the sensor if necessary. • Verify that the vent/air intake pipes are properly installed and that there are no obstructions. p.46
Delta T High• Verify that the system is full of water and that all air has been properly purged from the system. • Verify that the boiler is piped properly into the heating system. Refer to Section 5 - Hydronic Piping of the Crest Installation and Operation Manual for the proper piping methods for the Crest boiler. • Check for 120 vac to the boiler pump motor on a call for heat. If voltage is not present, check the wiring back to the main control board. Replace the main control board if necessary. • If 120 vac is present on a call for heat and the boiler pump is not operating, replace the pump. • Verify that the boiler pump is set to the proper speed or that the pump is the proper size. Reference Section 5 - Hydronic Piping of the Crest Installation and Operation Manual for boiler pump specifications. • Inspect the inlet and outlet sensors and associated wiring. Measure the resistance of the sensors and compare to the tables on page 38 of this manual. p.46
Outlet Temp High• Verify that the system is full of water and that all air has been properly purged from the system. • Verify that the boiler is piped properly into the heating system. Refer to Section 5 - Hydronic Piping of the Crest Installation and Operation Manual for the proper piping methods for the Crest boiler. • Check for 120 vac to the boiler pump motor on a call for heat. If voltage is not present, check wiring back to the main control board. Replace the main control board if necessary. • If 120 vac is present on a call for heat and the boiler pump is not operating, replace the pump. p.46
Outlet Temp High (continued)• Verify that the boiler pump is set to the proper speed or that the boiler pump is the proper size. Reference Section 5 - Hydronic Piping of the Knight Boiler Installation and Operation Manual for boiler pump specifications. • Inspect the outlet sensors and associated wiring. Measure the resistance of the sensors and compare to the tables on page 38 of this manual. p.47
Rem Ctrl Flt• Check set point of the external control. • Check the wiring between the external control and the unit. • Replace the control. p.47
Parameters Saved (will require a manual reset once the condition has been corrected. Press the RESET button on the SMART TOUCH display to reset.)• Press the RESET button on the SMART TOUCH display panel. p.47
Service Blk• Establish a heating load to remove the heat from the boiler loop. • Verify that the system is full of water and that all air has been properly purged from the system. • Verify that the boiler is piped properly into the heating system. Refer to Section 5 - Hydronic Piping of the Crest Installation and Operation Manual for the proper piping methods for the Crest boiler. • Check 120 vac to the boiler pump motor on a call for heat. If voltage is not present, check the wiring back to the main control board. Replace the main control board if necessary. • If 120 vac is present on a call for heat and the boiler pump is not operating, replace the pump. • Verify that the boiler pump is set to the proper speed or that the boiler pump is the proper size. Reference Section 5 - Hydronic Piping of the Crest Installation and Operation Manual for boiler pump specifications. p.47
Sensor Open (will require a manual reset once the condition has been corrected. Press the RESET button on the display to reset.)• Check the sensors and their associated wiring. Repair or replace the sensor or wiring if damaged. • Measure the resistance of the sensors and compare the resistance to the tables on page 38 of this manual. • Replace the sensor if necessary. p.48
Sensor Shorted (will require a manual reset once the condition has been corrected. Press the RESET button on the display to reset.)• Check the sensors and their associated wiring. Repair or replace the sensor or wiring if damaged. • Measure the resistance of the sensors and compare the resistance to the tables on page 38 of this manual. • Replace the sensor if necessary. p.48
Flue Sensor Open (will require a manual reset once the condition has been corrected. Press the RESET button on the display to reset.)• Check the sensor and its associated wiring. Repair or replace the sensor or wiring if damaged. • Measure the resistance of the sensors and compare the resistance to the tables on page 38 of this manual. • Replace the sensor in flue. • Replace the sensor if necessary. p.48
Flue Sensor Shorted (will require a manual reset once the condition has been corrected. Press the RESET button on the display to reset.)• Check the sensor and its associated wiring. Repair or replace the sensor or wiring if damaged. • Measure the resistance of the sensors and compare the resistance to the tables on page 38 of this manual. • Replace the sensor if necessary. p.48
Tank Open• Check the tank temperature. • Repair or replace the sensor wiring if damaged. • Replace the sensor if necessary. p.48
Blower Proving Switch Open 1 (will require a manual reset once the condition has been corrected. Press the RESET button on the display to reset.)• Check the wiring connections to switch. Wires should be connected to the common and normally open terminals. • Remove switch and check for blockage in the orifice. • Vent/air intake lengths exceed the maximum allowed lengths. Refer to Section 2 - General Venting of the Crest Installation and Operation Manual for proper lengths. • Check for obstruction or blockage in the vent/air intake pipes or at terminations. • Inspect the burner. Reference page 34 of this manual for removal and cleaning procedures. Replace if necessary. • Verify combustion air blower 1 is operating. Replace if necessary. • Inspect the heat exchanger. Reference page 35 of this manual for removal and cleaning procedures. • Faulty pressure switch. Replace switch. p.48
Blower Proving Switch Open 2 (will require a manual reset once the condition has been corrected. Press the RESET button on the display to reset.)• Check the wiring connections to switch. Wires should be connected to the common and normally open terminals. • Remove switch and check for blockage in the orifice. • Vent/air intake lengths exceed the maximum allowed lengths. Refer to Section 2 - General Venting of the Crest Installation and Operation Manual for proper lengths. • Check for obstruction or blockage in the vent/air intake pipes or at terminations. • Inspect the burner. Reference page 34 of this manual for removal and cleaning procedures. Replace if necessary. • Verify combustion air blower 2 is operating. Replace if necessary. • Inspect the heat exchanger. Reference page 35 of this manual for removal and cleaning procedures. • Faulty pressure switch. Replace switch. p.49
Burner Supply Temperature Differential (will require a manual reset once the condition has been corrected. Press the RESET button on the display to reset.)• Inspect the combustion air temperature sensor and associated wiring. • Measure the resistance of the combustion air temperature sensor and compare to Table 3E on page 38 of this manual • Replace the sensor if necessary. • Verify that the vent / air intake pipes are properly installed and that there are no obstructions. p.49
Burner Supply Temperature High 1 (will require a manual reset once the condition has been corrected. Press the RESET button on the display to reset.)• Check if the vent backflow preventer is installed for boilers commonly vented. • Check if the vent backflow preventer is stuck open while the unit is off. • Inspect the combustion air temperature sensor and associated wiring. • Measure the resistance of the combustion air temperature sensor and compare to Table 3E on page 38 of this manual. • Replace the sensor if necessary. p.49
Burner Supply Temperature High 2 (will require a manual reset once the condition has been corrected. Press the RESET button on the display to reset.)• Check if the vent backflow preventer is installed for boilers commonly vented. • Check if the vent backflow preventer is stuck open while the unit is off. • Inspect the combustion air temperature sensor and associated wiring. • Measure the resistance of the combustion air temperature sensor and compare to Table 3E on page 38 of this manual. • Replace the sensor if necessary. p.49
Too Many Resets - Try Later• Wait 15 minutes and try again. • Turn power off to unit, wait 30 seconds and then turn power back on. p.50
Internal Fault• Replace the main control board. p.50
Writing to Memos• Replace the main control board. p.50
Flue Temp Shutdown• Inspect the heat exchanger. Reference page 35 of this manual for the procedure on how to clean the flue side of the heat exchanger. • Inspect the flue sensor and associated wiring. Measure the resistance of the flue sensor and compare to Table 3E on page 38 of this manual. Replace the sensor if necessary. • Verify that the vent/air intake pipes are properly installed and that there are no obstructions. • Replace the main control board. p.50
Delta T Shutdown• Verify that the system is full of water and that all air has been properly purged from the system. • Verify that the boiler is piped properly into the heating system. Refer to Section 5 - Hydronic Piping of the Crest Installation and Operation Manual for the proper piping methods for the Crest boiler. • Check for voltage to the boiler pump motor on a call for heat. If voltage is not present, check the wiring back to the pump relay. Replace the pump relay if necessary. • If 120 VAC is present on a call for heat and the boiler pump is not operating, replace the pump. • Verify that the boiler pump is set to the proper speed or that the pump is the proper size. Reference Section 5 - Hydronic Piping of the Crest Installation and Operation Manual for boiler pump specifications. p.50
Outlet Temp Shutdown• Verify that the system is full of water and that all air has been properly purged from the system. • Verify that the boiler is piped properly into the heating system. Refer to Section 5 - Hydronic Piping of the Crest Installation and Operation Manual for the proper piping methods for the Crest boiler. • Check for voltage to the boiler pump motor on a call for heat. If voltage is not present, check wiring back to the pump relay. Replace the pump relay if necessary. • If 120 VAC is present on a call for heat and the boiler pump is not operating, replace the pump. p.51
Watch Dog Error• Replace the main control board. p.51
Write EEProm• Replace the main control board. p.51
CRC Parameters• Replace the main control board. p.51
No Error Stored• Press the RESET button on the SMART TOUCH display panel. p.51

Ask about the Lochinvar 3.5

Owners and our team usually reply within a day — and your question helps the next person too.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
No questions yet about the Lochinvar 3.5

Be the first to ask — other owners or our team will answer.