EN
Official user manual

Lobos Tech Ethernet Switch (LB-FEA800M)

85 pages·1.6 MB·Switch·PDF·ENDEFRITNLJA
Lobos Tech Ethernet Switch (LB-FEA800M)
Table of Contents 80 sections User Guide · LB-FEA800M · 1. Introduction · Features · … ShowHide
User Guidep.1LB-FEA800Mp.11. Introductionp.3Featuresp.3Software Featurep.4SNMPp.4RFC 2674VLAN MIBp.4VLANp.4IGMP, RFC 2068 HTTP,p.5Package Contentsp.5Ethernet Switching Technologyp.6Management Methodsp.8Console and Telnet Managementp.8Web-based Managementp.8SNMP Network Managementp.82. Hardware Descriptionp.9Physical dimensionsp.9Front Panelp.9LED Indicatorsp.10Rear Panelp.11Desktop Installationp.11Attaching Rubber Feetp.11Power Onp.123. Network Applicationp.13Desktop Applicationp.13Segment Applicationp.134. Network Configurationp.15Connecting to the Console Portp.15Console – Menup.16Main Menup.17Status and Countersp.17Switch Static Configurationp.204-3-6.MAC Address Configurationp.304-3-6-1.Static MAC Addressp.304-3-6-2.Filtering MAC Addressp.324-3-7.Misc Configurationp.334-3-7-1.Port Securityp.334-3-7-2.MAC Age Intervalp.344-3-7-3.Broadcast Storm Filteringp.354-3-7-4.Max bridge transmit delay boundp.364-4-1.STPp.374-4-1-2.System Configurationp.384-4-1-3.Perport Configurationp.394-4-2.SNMPp.404-4-2-1.System Optionsp.404-4-2-3.Trap Managersp.424-4-3.GVRPp.444-4-4.LACPp.454-4-4-1.Aggregator Settingp.454-4-4-2.State Activityp.464-4-4-3.LACP Statusp.475-2. Port statusp.521. port statusp.525-4-1. IP Addressp.545-4-2. Switch Settingp.555-4-2-1.Basicp.555-4-2-2.Advancedp.565-4-3. Console Port Informationp.615-4-4. Port Controlsp.625-4-5. Trunkingp.635-4-5-2. Aggregator Informationp.655-4-5-3. State Activityp.655-4-6. Filter Databasep.675-4-6-1. IGMP Snoopingp.675-4-6-2. Static MAC Addressp.685-4-6-3. Port Securityp.695-4-6-4. MAC Filteringp.695-4-7. VLAN configurationp.705-4-7-1. Basicp.715-4-8. Spanning Treep.735-4-10. SNMPp.765-4-11.Security Managerp.785-4-12. TFTP Update Firmwarep.785-4-13. Configuration Backupp.795-4-13-1. TFTP Restore Configurationp.795-4-13-2. TFTP Backup Configurationp.795 -4-14. Reset Systemp.815-4-15. Rebootp.816. Technical Specificationsp.827. Troubleshootingp.84
Page 1 of the Lobos Tech Ethernet Switch (LB-FEA800M) user manual — LB-FEA800M
Page 1 · click to enlarge
Page 1

User Guide

LB-FEA800M

Rev.1.0

2005/1/27

Page 2 of the Lobos Tech Ethernet Switch (LB-FEA800M) user manual — User Guide
Page 2 · click to enlarge
Page 2
Page 2 of the Lobos Tech Ethernet Switch (LB-FEA800M) user manual — User Guide
Page 3 of the Lobos Tech Ethernet Switch (LB-FEA800M) user manual — Features
Page 3 · click to enlarge
Page 3

1. Introduction

The LB-FEA800M is compact desktop size switches that are ideal solutions

for SOHO (Small Office or Home Office) network user. It provides wire-speed,

Fast Ethernet switching function that allows high-performance, low-cost

connection. The Switches feature a store-and-forward switching and it can

auto-learn and store source address on an 8K-entry MAC address table.

The Switches provides 8 switched auto-sensing 10/100 Mbps RJ-45 Ethernet

ports and features Auto MDI/MDIX function for each port. [In general, MDI

means connecting to another Hub or Switch while MDIX means connecting to

a workstation or PC. Therefore, Auto MDI/MDIX means that you can connect

to another Switch or workstation without changing non-crossover or crossover

cabling. ]

With there build-in Web-based Management, managing and configuring the

LB-FEA800M becomes easier. From cabinet management to port-level control

and monitoring, you can visually configure and manage your network via Web

Browser. Just click your mouse instead of typing command strings. However,

the LB-FEA800M can also be managed via Telnet, Console, or SNMP

Management.

Features

n 8 10/100BASE-TX intelligent switch

n Switch fabric up to 3.8Gbps

n Fully software feature for Layer 2 management switch

n IGMP support for Multi-media application

n Port Mirror supported

n Spanning Tree, SNMP, RMON supported

n Support Port-based VLAN

Page 4 of the Lobos Tech Ethernet Switch (LB-FEA800M) user manual — VLAN
Page 4 · click to enlarge
Page 4

n IEEE802 .1Q VLAN, GVRP supported

n Support Class of Service

n Broadcast Storm filter supported

n Support Port Security

n IEEE802.3ad Port trunk with LACP supported

Software Feature

RFC 1157 SNMP, RFC 1213 MIB II, Bridge MIB, RFC

1643 Ethernet Like, RFC 1493 Bridge MIB, RFC 1757

SNMP

RMON1, LANTECH Enterprise MIB, RFC 1215 Trap,

RFC 2674VLAN MIB

RS-232 console management (Rear side)

IEEE 802.3ad Trunk with LACP for load distribution

control and fail over recover

Up to 4 ports per group, max 4 Groups

Class of Service Global system supports 2 queues for Hi and Low priority

Global System support 8 levels of priority and mapping

to Hi/Low priority queue for Class of Service

Port based VLAN, 802.1Q Tag VLAN, Protocol Type

VLAN

VLAN ID up to 4094, VLANs up to 256 groups

Support IGMP Snooping, supports 256 groups.

Support 2 types of Query mode for Enable/Disable or

Show 8 more labels / short text on this page
Web management (IE) · Management · Telnet · Trunk · QoS · VLAN, GVRP support · IP Multicast · Auto Query
Page 5 of the Lobos Tech Ethernet Switch (LB-FEA800M) user manual — IGMP, RFC 2068 HTTP,
Page 5 · click to enlarge
Page 5

Support port static MAC address lock, MAC Filter, Port

Use this feature to analysis port traffic for this switch. It

supports max 8 ports.

None, 5%, 10%, 15%, 20%, 25%

Spanning Tree IEEE802.1d support

RFC 768 UDP, RFC 783 TFTP, RFC 791 IP, RFC792

ICMP, RFC 854 TELNET Server/Client, RFC 1112

IGMP, RFC 2068 HTTP,

Package Contents

Unpack the contents of the LB-FEA800M and verify them against the checklist

below.

n Four Rubber Feet

Lobos Tech Ethernet Switch (LB-FEA800M) — IGMP, RFC 2068 HTTP, diagram (page 5)
Fig. 1
Lobos Tech Ethernet Switch (LB-FEA800M) — IGMP, RFC 2068 HTTP, diagram (page 5)
Fig. 2
Show 11 more labels / short text on this page
Filter Database · Security · Port Mirror · Broadcast · Control · RFC Standard · n LB-FEA800M · n Power Cord · n RS-232 cable · n User Guide · LB-FEA800M Power Cord
Page 6 of the Lobos Tech Ethernet Switch (LB-FEA800M) user manual — Ethernet Switching Technology
Page 6 · click to enlarge
Page 6
Lobos Tech Ethernet Switch (LB-FEA800M) — Ethernet Switching Technology diagram (page 6)
Fig. 3 · Ethernet Switching Technology

Rubber Feet RS-232 cable User Guide

Figure 1-2. Package Contents

Compare the contents of your LB-FEA800M package with the checklist above.

IF any item is missing or damaged, please contact your local dealer for

service.

Ethernet Switching Technology

Ethernet Switching Technology dramatically boosted the total bandwidth of a

network, eliminated congestion problems inherent with Carrier Sense multiple

access with Collision Detection (CSMA/CD) protocol, and greatly reduced

unnecessary transmissions.

This revolutionized networking. First, by allowing two-way, simultaneous

transmissions over the same port (Full-duplex), which essentially doubled the

bandwidth. Second, by reducing the collision domain to a single switch-port,

which eliminated the need for carrier sensing. Third, by using the

store-and-forward technology’s approach of inspecting each packet to

intercept corrupt or redundant data, switching eliminated unnecessary

transmission that slow the network. By employing address learning, which

replaced the inefficient receiving port.

Auto-negotiation regulates the speed and duplex of each port, based on the

capability of both devices. Flow-control allows transmission from a 100Mbps

node to a 10Mbps node without loss of data. Auto-negotiation and flow-control

may require disablement for some networking operations involves legacy

equipment. Disabling the auto-negotiation is accomplished by fixing the speed

or duplex of a port.

Page 7 of the Lobos Tech Ethernet Switch (LB-FEA800M) user manual — Ethernet Switching Technology
Page 7 · click to enlarge
Page 7

Ethernet Switching Technology supplied higher performance at costs lower

than other solutions. Wider bandwidth, no congestion, and the reduction in

traffic is why switching is replacing expensive routers and inefficient hubs as

the ultimate networking solution. Switching brought a whole new way of

thinking to networking.

Page 8 of the Lobos Tech Ethernet Switch (LB-FEA800M) user manual — SNMP Network Management
Page 8 · click to enlarge
Page 8

Management Methods

The LB-FEA800M series supports following management methods:

n Console and Telnet Management

n SNMP Network Management

Console and Telnet Management

Console Management is done through the RS-232 Console Port. Managing

the LB-FEA800M in this method requires a direct connection between PC and

the 8TP+1Fiber Management Switch. While Telnet management is done over

the network. Once the LB-FEA800M is on the network, you can use Telnet to

Log in and change the configuration.

Web-based Management

The Switch provides an embedded HTML web site residing in flash memory. It

offers advanced management features and allow users to manage the

LB-FEA800M from anywhere on the network through a standard browser such

as Microsoft Internet Explorer.

SNMP Network Management

SNMP (Simple Network Management Protocol) provides a means to monitor

and control network device, and to manage configurations, statistic collection,

performance, and security.

n Web-based Management

Page 9 of the Lobos Tech Ethernet Switch (LB-FEA800M) user manual — Front Panel
Page 9 · click to enlarge
Page 9

2. Hardware Description

This section mainly describes the hardware of the LB-FEA800M.

Physical dimensions

The physical dimensions of the LB-FEA800M is 250mm x 133mm x 37mm (L

x W x H)

Front Panel

The Front Panel of the LB-FEA800M consist of 8x auto-sensing 10/100Mbps

Ethernet RJ-45 ports (automatic MDI/MDIX) and the LED indicators are also

located on the frond panel of the switch.

Lobos Tech Ethernet Switch (LB-FEA800M) — Front Panel diagram (page 9)
Fig. 4 · Front Panel

Figure 2-1. The Front Panel of theLB-FEA800M

n RJ-45 Ports (Auto MDI/MDIX)8x 10/100 autosensing for 10Base-T or

100Base-TX connections.

[In general, MDI means connecting to another Hub or Switch while MDIX

means connecting to a workstation or PC. Therefore, Auto MDI/MDIX

means that you can connect to another Switch or workstation without

changing non-crossover or crossover cabling. ]

Page 10 of the Lobos Tech Ethernet Switch (LB-FEA800M) user manual — LED Indicators
Page 10 · click to enlarge
Page 10

LED Indicators

There are three LED-Indicators (100M, LNK/ACT, FDX/COL) for each UTP

port. The following table provides descriptions of the LED statuses and

meaning. They provide a real-time indication of systematic operation status.

Lobos Tech Ethernet Switch (LB-FEA800M) — LED Indicators diagram (page 10)
Fig. 5 · LED Indicators

Figure 2-2. LED Indicators

Lobos Tech Ethernet Switch (LB-FEA800M) — LED Indicators diagram (page 10)
Fig. 6 · LED Indicators
LEDStatusColorDescription PowerOnGreenPower On 100MOnGreenThe port is operating at the speed of 100Mbps. OffIn 10Mbps mode or no device attached LNK /ACTOnGreenThe port is successfully connecting with the device. BlinksGreenThe port is receiving or transmitting data. OffNo device attached. FDX /COLOnOrangeThe port is operating in Full-duplex mode. BlinksOrangeCollision of Packets occurs in the port.
Page 11 of the Lobos Tech Ethernet Switch (LB-FEA800M) user manual — Attaching Rubber Feet
Page 11 · click to enlarge
Page 11

Half-duplex mode or no

device attached.

Table 2-1. The description of LED Indicator

Rear Panel

The Console port and 3-pronged power plug are located at the Rear Panel of

the LB-FEA800M as shown in Figure 2-3. The Switches will work with AC in

the range 100-240V AC, 50-60Hz.

Lobos Tech Ethernet Switch (LB-FEA800M) — Rear Panel diagram (page 11)
Fig. 7 · Rear Panel

Figure 2-3 The Rear Panel of the LB-FEA800M

Console Port: Console management can be done through the Console Port.

It requires a direct connection between the Switch and an end station (PC) via

a RS-232 cable.

Desktop Installation

Set the switch on a sufficiently large flat space with a power outlet nearby. The

surface where you put your Switch should be clean, smooth, level, and sturdy.

Make sure there is enough clearance around the Switch to allow

attachment of cables, power cord and air circulation.

Attaching Rubber Feet

1. Make sure mounting surface on the bottom of the Switch is grease and

dust free.

Off

Page 12 of the Lobos Tech Ethernet Switch (LB-FEA800M) user manual — Power On
Page 12 · click to enlarge
Page 12
2. Remove adhesive backing from your Rubber Feet.
3. Apply the Rubber Feet to each corner on the bottom of the Switch. These

footpads can prevent the Switch from shock/vibration.

Lobos Tech Ethernet Switch (LB-FEA800M) — Power On diagram (page 12)
Fig. 8 · Power On

Figure 2-4. Attaching Rubber Feet to each corner on the bottom of the Switch

Power On

Connect the power cord to the power socket on the rear panel of the Switch.

The other side of power cord connects to the power outlet. Check the power

indicator on the front panel to see if power is properly supplied.

Page 13 of the Lobos Tech Ethernet Switch (LB-FEA800M) user manual — Segment Application
Page 13 · click to enlarge
Page 13

3. Network Application

This section provides you a few samples of network topology in which the

Switch is used. In general, the LB-FEA800M is designed to be used as a

desktop or segment switch.

Desktop Application

The LB-FEA800M series are designed to be a desktop size switch that is an

ideal solution for small workgroup. The Switch can be used as a standalone

switch to which personal computers, server, printer server are directly

connected to form small workgroup.

Lobos Tech Ethernet Switch (LB-FEA800M) — Desktop Application diagram (page 13)
Fig. 9 · Desktop Application

Figure 3-1. Desktop Application

Segment Application

For enterprise networks where large data broadcast are constantly processed,

Page 14 of the Lobos Tech Ethernet Switch (LB-FEA800M) user manual — 3. Network Application
Page 14 · click to enlarge
Page 14

this switch is suitable for department user to connect to the corporate

backbone.

Lobos Tech Ethernet Switch (LB-FEA800M) — 3. Network Application diagram (page 14)
Fig. 10 · 3. Network Application

Figure 3-2 Segment Application

You can use the LB-FEA800M to connect PCs, workstations, and servers to

each other by connecting these devices directly to the Switch. All the devices

in this network can communicate with each other. Connecting servers to the

backbone switch allow other users to access the server’s data.

The Switch automatically learns node address, which are subsequently used

to filter and forward all traffic based on the destination address. You can use

any of the RJ-45 port of the LB-FEA800M to connect with another Switch or

Hub to interconnect each of your small-switched workgroups to form a larger

switched network.

Page 15 of the Lobos Tech Ethernet Switch (LB-FEA800M) user manual — Connecting to the Console Port
Page 15 · click to enlarge
Page 15

4. Network Configuration

This Section explains how to configure console management via a direct

connection to the console port of the LB-FEA800M.

Console management involves the administration of the Switch via a direct

connection to the RS-232 console port. This port is a female DB-9 connector.

From the main menu of the console program, user has access to manage the

functions of the Switch.

Connecting to the Console Port

Use the supplied RS-232 cable to connect a terminal or PC to the console port.

The terminal or PC to be connected must support the terminal emulation

program.

Lobos Tech Ethernet Switch (LB-FEA800M) — Connecting to the Console Port diagram (page 15)
Fig. 11 · Connecting to the Console Port

Figure 4-1. Connecting the Switch to a terminal via RS-232 cable

After the connection between Switch and PC is finished, turn on the PC and

run a terminal emulation program or Hyper Terminal to match the following

default characteristics of the console port:

Page 16 of the Lobos Tech Ethernet Switch (LB-FEA800M) user manual — Console – Menu
Page 16 · click to enlarge
Page 16
Baud Rate9600 bps
Lobos Tech Ethernet Switch (LB-FEA800M) — Console – Menu diagram (page 16)
Fig. 12 · Console – Menu
Data Bits8
Paritynone
Stop Bit1
Control flowNone

Figure 4-2. The settings of communication parameters

After you have finished parameter settings, press “ Enter “ Key and the Main

Menu of console management appears.

Console – Menu

1. The switch also provide a serial interface to manage and monitor the

switch, user can follow the Console Port Information provide by web to

use windows HyperTerminal program to link the switch.

2. You can type user name and password to login. The default user name is

“ root”; the default password is “root ”.

Lobos Tech Ethernet Switch (LB-FEA800M) — Console – Menu diagram (page 16)
Fig. 13 · Console – Menu
Page 17 of the Lobos Tech Ethernet Switch (LB-FEA800M) user manual — Status and Counters
Page 17 · click to enlarge
Page 17

Main Menu

There are five items for selected as follows.

Lobos Tech Ethernet Switch (LB-FEA800M) — Main Menu diagram (page 17)
Fig. 14 · Main Menu

n Status and Counters: Show the status of the switch.

n Switch Static Configuration: Configure the switch.

n Protocol Related Configuration: Configure the protocol function.

n Reboot SwitchRestart the system or reset switch to default

configuration.

n Logout: Exit the menu line program.

The control key as follow provided in all menus:

n Tab: Move the vernier to next item.

n Backspace: Move the vernier to previous item.

n Enter: Select item.

n Space: Toggle selected item to next configure.

Status and Counters

<Control Key>

Page 18 of the Lobos Tech Ethernet Switch (LB-FEA800M) user manual — Main Menu
Page 18 · click to enlarge
Page 18
Lobos Tech Ethernet Switch (LB-FEA800M) — Main Menu diagram (page 18)
Fig. 15 · Main Menu

You can press the key of Tab or Backspace to choose item, and press Enter

key to select item.

This page display every port status

n Type: Display the port type.

n Enabled: Display the port is enabled or disable depended on user setting.

Enable will be display “Yes”; disable will be display “No”.

n Status: Display the port is link or no link, “Down” is no link, and “Up” is

link.

n Mode: Display the port speed and duplex.

n FlowCtrl: Display the flow control status is enable or disable mode.

Lobos Tech Ethernet Switch (LB-FEA800M) — Main Menu diagram (page 18)
Fig. 16 · Main Menu

Port Status

Page 19 of the Lobos Tech Ethernet Switch (LB-FEA800M) user manual — Main Menu
Page 19 · click to enlarge
Page 19

You can press the key of Tab or Backspace to choose action menu, and

press Enter key to select item

<Quit>: Exit the page of port status, and return to previous menu.

<Previous Page>: Display previous page.

<Next page>: Display next page.

The following information provides a view of the current status of the unit.

Lobos Tech Ethernet Switch (LB-FEA800M) — Main Menu diagram (page 19)
Fig. 17 · Main Menu

You can press the key of Tab or Backspace to choose action menu, and

press Enter key to select item

<Quit>: Exit the page of port status, and return to previous menu.

<Reset All>: Set all count to 0.

<Previous Page>: Display previous page.

<Next page>: Display next page.

Actions-> · Port Counters · Actions->

Page 20 of the Lobos Tech Ethernet Switch (LB-FEA800M) user manual — Switch Static Configuration
Page 20 · click to enlarge
Page 20

4-2-3. System Information

System Description: Display the name of device type.

MAC Address: The unique hardware address assigned by manufacturer.

Firmware Version: Display the switch’s firmware version.

Hardware Version: Display the switch’s Hardware version.

Default configure value versionDisplay write to default EEPROM value

version.

Lobos Tech Ethernet Switch (LB-FEA800M) — Switch Static Configuration diagram (page 20)
Fig. 18 · Switch Static Configuration

Switch Static Configuration

Lobos Tech Ethernet Switch (LB-FEA800M) — Switch Static Configuration diagram (page 20)
Fig. 19 · Switch Static Configuration

You can press the key of Tab or Backspace to choose item, and press Enter

key to select item

Page 21 of the Lobos Tech Ethernet Switch (LB-FEA800M) user manual — Switch Static Configuration
Page 21 · click to enlarge
Page 21
Lobos Tech Ethernet Switch (LB-FEA800M) — Switch Static Configuration diagram (page 21)
Fig. 20 · Switch Static Configuration

This page provide user to configure the device information.

<Edit>Configure all items. Finished configure press Backspace to go back

action menu line.

<Save>: Save all configure value.

<Quit>: Exit the page of device information and return to previous menu.

Administration Configuration · Device Information · Actions->

Page 22 of the Lobos Tech Ethernet Switch (LB-FEA800M) user manual — Switch Static Configuration
Page 22 · click to enlarge
Page 22
Lobos Tech Ethernet Switch (LB-FEA800M) — Switch Static Configuration diagram (page 22)
Fig. 21 · Switch Static Configuration

User can configure the IP setting and fill in the new value.

<Edit>Configure all items. Finished configure press ESC to go back action

menu line.

<Save>: Save all configure value.

<Quit>: Exit the page of IP configuration and return to previous menu.

Lobos Tech Ethernet Switch (LB-FEA800M) — Switch Static Configuration diagram (page 22)
Fig. 22 · Switch Static Configuration

IP Configuration · Actions->

Page 23 of the Lobos Tech Ethernet Switch (LB-FEA800M) user manual — Switch Static Configuration
Page 23 · click to enlarge
Page 23

Use this page; user can change web management user name.

Lobos Tech Ethernet Switch (LB-FEA800M) — Switch Static Configuration diagram (page 23)
Fig. 23 · Switch Static Configuration

Use this page; user can change web management user password.

Lobos Tech Ethernet Switch (LB-FEA800M) — Switch Static Configuration diagram (page 23)
Fig. 24 · Switch Static Configuration

Change Username · Change Password

Page 24 of the Lobos Tech Ethernet Switch (LB-FEA800M) user manual — Switch Static Configuration
Page 24 · click to enlarge
Page 24

Port / Trunk Configuration

This page can change every port status and configure trunk group. Press TAB

key to change configure of per item.

1. Enabled: User can disable or enable this port control.
2. Auto Negotiate: User can set auto negotiation is enable or disable of per

port.

3. Speed/Duplex Config: User can set 100Mbps or 10Mbps speed on port

1~port 8, only 100Mbps on port 9, and set full-duplex or half-duplex mode.

4. Flow Control: User can set flow control function is enable or disable.
5. Group: User can set trunk group for port1~prot8. There are four trunk

groups to provided configure.

Lobos Tech Ethernet Switch (LB-FEA800M) — Switch Static Configuration diagram (page 24)
Fig. 25 · Switch Static Configuration

<Quit>: Exit the page of port configuration and return to previous menu.

<Edit>Configure all items. Finished configure press ESC to go back action

menu line.

<Save>: Save all configure value.

<Previous Page>: Return to previous page to configure.

<Next page>: Go to next page to configure.

Actions->

Page 25 of the Lobos Tech Ethernet Switch (LB-FEA800M) user manual — Switch Static Configuration
Page 25 · click to enlarge
Page 25

The port mirroring is a method for monitor traffic in switched networks. Traffic

through ports can be monitored by one specific port. That is traffic goes in or

out monitored ports will be duplicated into monitoring port. Press Space key to

change configure of per item.

1. Analysis State: Type YES or NO for port-morrioing function.
2. Mirroring Port: It’s mean mirror port can be used to see all monitor port

traffic.

3. Source Port: The ports you want to monitor. All monitor port traffic will be

copied to sniffer port. You can select max 9 monitor ports in the switch.

User can choose want to monitored RX frames only or TX frames only or

both RX and TX frame from the port at Action item.

Lobos Tech Ethernet Switch (LB-FEA800M) — Switch Static Configuration diagram (page 25)
Fig. 26 · Switch Static Configuration
<Quit>Exit the page of port monitoring configuration and return to previous

menu.

<Edit>Configure all items. Finished configure press ESC to go back action

menu line.

<Save>: Save all configure value.

<Previous Page>: Return to previous page to configure.

Port Mirroring Configuration · Actions->

Page 26 of the Lobos Tech Ethernet Switch (LB-FEA800M) user manual — Switch Static Configuration
Page 26 · click to enlarge
Page 26

<Next page>: Go to next page to configure.

Lobos Tech Ethernet Switch (LB-FEA800M) — Switch Static Configuration diagram (page 26)
Fig. 27 · Switch Static Configuration
1. PVID (Port VID): Set the port VLAN ID that will be assigned to untagged

traffic on a given port. This feature is useful for accommodating devices

that you want to participate in the VLAN but that don’t support tagging.

Only one untagged VLAN is allowed per port.

2. Ingress Filter 1: It’s matches that Ingress Filtering Rule 1 on web.

Forward packets only with VID matching this port’s configured VID. Press

Space key to choose forward or drop the frame that VID not matching this

port’s configured VID.

3. Ingress Filter 2: It matches that Ingress Filtering Rule 2 on web. Drop

untagged frame.

Press Space key to choose drop or forward the untagged frame.

VLAN Configuration · VLAN Configure

Page 27 of the Lobos Tech Ethernet Switch (LB-FEA800M) user manual — Switch Static Configuration
Page 27 · click to enlarge
Page 27
Lobos Tech Ethernet Switch (LB-FEA800M) — Switch Static Configuration diagram (page 27)
Fig. 28 · Switch Static Configuration

Create a VLAN Group

Create a VLAN and add tagged /untagged member ports to it.

1. VLAN Name: Type a name for the new VLAN.
2. VLAN ID: Type a VID (between 2~4094). The default is 1.
3. Protocol VLAN: Press Space key to choose protocols type.
4. Mode: Press Space key to choose VLAN member. There are three types

to select as 802.1Q, 802.1Q with GVRP and PortBase.

n Untagged: the member port is un-tagged port.

n Tagged: the member port is tagged port.

n NO: The port is not member of this VLAN group.

Lobos Tech Ethernet Switch (LB-FEA800M) — Switch Static Configuration diagram (page 27)
Fig. 29 · Switch Static Configuration
Page 28 of the Lobos Tech Ethernet Switch (LB-FEA800M) user manual — Switch Static Configuration
Page 28 · click to enlarge
Page 28

<Quit>: Exit this page and return to previous menu.

<Edit>Configure all items. Finished configure press ESC to go back action

menu line.

<Save>: Save all configure value.

<Previous Page>: Return to previous page to configure.

<Next page>: Go to next page to configure.

Edit / Delete a VLAN Group

In this page, user can edit or delete a VLAN group.

1. Press or item.
2. Choose the VLAN group that you want to edit or delete and then press

enter.

3. User can modify the protocol VLAN item and the member port is tagged or

un-tagged and remove some member ports from this VLAN group.

4. After edit or delete VLAN, press key to save all configures value.

2.The default VLAN can’t be deleting.

Lobos Tech Ethernet Switch (LB-FEA800M) — Switch Static Configuration diagram (page 28)
Fig. 30 · Switch Static Configuration

Actions-> · Priority Configuration

Page 29 of the Lobos Tech Ethernet Switch (LB-FEA800M) user manual — Switch Static Configuration
Page 29 · click to enlarge
Page 29
1. There are 0~7 priority level can map to high or low queue.
2. High/Low Queue Service Ration H:L : User can select the ratio of high

priority packets and low priority packets.

Lobos Tech Ethernet Switch (LB-FEA800M) — Switch Static Configuration diagram (page 29)
Fig. 31 · Switch Static Configuration
<Edit>Configure all items. Finished configure press ESC to go back action

menu line.

<Save>: Save all configure value.

<Quit>: Exit this page and return to previous menu.

n First In First OutThe sequence of packets sent is depend on arrive

order.

n High to Low: The high priority packets sent before low priority packets.

n RatioSelect the preference given to packets in the switch's high-priority

queue.

These options represent the number of high priority packets sent before one

low priority packet is sent. For example, 2 High: 1 Low means that the switch

sends 2 high priority packets before sending 1 low priority packet.

Actions->

Page 30 of the Lobos Tech Ethernet Switch (LB-FEA800M) user manual — 4-3-6-1.Static MAC Address
Page 30 · click to enlarge
Page 30

4-3-6.MAC Address Configuration

Lobos Tech Ethernet Switch (LB-FEA800M) — 4-3-6.MAC Address Configuration diagram (page 30)
Fig. 32 · 4-3-6.MAC Address Configuration

4-3-6-1.Static MAC Address

When you add a static MAC address, it remains in the switch's address

table, regardless of whether the device is physically connected to the

switch. This saves the switch from having to re-learn a device's MAC

address when the disconnected or powered-off device is active on the

network again.

In this page user can add / modify / delete a static MAC address.

Lobos Tech Ethernet Switch (LB-FEA800M) — 4-3-6-1.Static MAC Address diagram (page 30)
Fig. 33 · 4-3-6-1.Static MAC Address
Page 31 of the Lobos Tech Ethernet Switch (LB-FEA800M) user manual — 4-3-6.MAC Address Configuration
Page 31 · click to enlarge
Page 31

Add static MAC address

1.Press <Add> --> <Edit> key to add a static MAC address.

2.Enter the MAC address to and from which the port should

permanently forward traffic, regardless of the devices network activity.

3.In the Port num item, enter the port number.

4.If tag-based (802.1Q) VLAN are set up on the switch, static addresses

are associated with individual VLANs. Type the VID to associate with

the MAC address.

5. Press ESC to go back action menu line, and then select to

save all configure value.

Edit static MAC address

1.Press <Edit> key to modify a static MAC address.

2.Choose the MAC address that you want to modify and then press

enter.

3.Press <Edit> key to modify all the items.

4.Press ESC to go back action menu line, and then select <Save> to

save all configure value.

Delete static MAC address

1.Press <Delete> key to delete a static MAC address.

2.Choose the MAC address that you want to delete and then press

enter.

3.After delete static MAC address, you have to press <Save> to

complete the deleting operation.

Page 32 of the Lobos Tech Ethernet Switch (LB-FEA800M) user manual — 4-3-6-2.Filtering MAC Address
Page 32 · click to enlarge
Page 32

4-3-6-2.Filtering MAC Address

Lobos Tech Ethernet Switch (LB-FEA800M) — 4-3-6-2.Filtering MAC Address diagram (page 32)
Fig. 34 · 4-3-6-2.Filtering MAC Address

Edit Filtering MAC address

1.Press <Edit> key to modify a static Filtering address.

2.Choose the MAC address that you want to modify and then press

enter.

3.Press <Edit> key to modify all the items.

4.Press ESC to go back action menu line, and then select <Save> to

save all configure value.

Delete Filtering MAC address

1.Press <Delete> key to delete a Filtering MAC address.

2.Choose the MAC address that you want to delete and then press

enter.

3.After delete Filtering MAC address, you have to press <Save> to

complete the deleting operation.

Page 33 of the Lobos Tech Ethernet Switch (LB-FEA800M) user manual — 4-3-7-1.Port Security
Page 33 · click to enlarge
Page 33

4-3-7.Misc Configuration

Lobos Tech Ethernet Switch (LB-FEA800M) — 4-3-7.Misc Configuration diagram (page 33)
Fig. 35 · 4-3-7.Misc Configuration

4-3-7-1.Port Security

A port in security mode will be “locked” without permission of address

learning. Only the incoming packets with SMAC already existing in the

address table can be forwarded normally. User can disable the port from

learning any new MAC addresses, and then use the static MAC

addresses screen to define a list of MAC addresses that can use the

secure port.

Lobos Tech Ethernet Switch (LB-FEA800M) — 4-3-7-1.Port Security diagram (page 33)
Fig. 36 · 4-3-7-1.Port Security
Page 34 of the Lobos Tech Ethernet Switch (LB-FEA800M) user manual — 4-3-7-2.MAC Age Interval
Page 34 · click to enlarge
Page 34

1.Press <Edit> to enable or disable the port security.

2.Press Space key to choose enable / disable item.

3.Press ESC to go back action menu line, and then select <Save> to

save all configure value.

4-3-7-2.MAC Age Interval

Type the number of seconds that an inactive MAC address remains in

the switch’s address table. The valid range is 300~765 seconds. Default

is 300 seconds.

Lobos Tech Ethernet Switch (LB-FEA800M) — 4-3-7-2.MAC Age Interval diagram (page 34)
Fig. 37 · 4-3-7-2.MAC Age Interval
<Edit>Configure all items. Finished configure press ESC to go back

action menu line.

<Save>: Save all configure value.

<Quit>: Exit this page and return to previous menu.

Actions->

Page 35 of the Lobos Tech Ethernet Switch (LB-FEA800M) user manual — 4-3-7-3.Broadcast Storm Filtering
Page 35 · click to enlarge
Page 35

4-3-7-3.Broadcast Storm Filtering

This page is configuring broadcast storm control, press <Edit> to

configure the broadcast storm filter mode.

Press Space key to choose the threshold value. The valid threshold

value are 5%,10%,15%,20%,25% and NO.

Lobos Tech Ethernet Switch (LB-FEA800M) — 4-3-7-3.Broadcast Storm Filtering diagram (page 35)
Fig. 38 · 4-3-7-3.Broadcast Storm Filtering
<Edit>Configure all items. Finished configure press ESC to go back

action menu line.

<Save>: Save all configure value.

<Quit>: Exit this page and return to previous menu.

Actions->

Page 36 of the Lobos Tech Ethernet Switch (LB-FEA800M) user manual — 4-3-7-4.Max bridge transmit delay bound
Page 36 · click to enlarge
Page 36

4-3-7-4.Max bridge transmit delay bound

Max bridge transmit delay boundLimit the packets queuing time in

switch. If enable, the packets queued exceed will be drop. Press Space

key to set the time. This valid value are 1sec, 2sec, 4sec and off. Default

is 1 seconds.

Enable Delay BoundLimit the low priority packets queuing time in

switch. If enable, the low priority packet stays in switch exceed Max

Delay Time, it will be sent. Press Space key to enable or disable this

function.

Max Delay TimeTo set the time that low priority packets queuing in

switch. The valid range is 1~255 ms.

before enable Delay Bound, because Enable Delay Bound must be

work under “Max bridge transit delay bound control is enabled” situation.

Lobos Tech Ethernet Switch (LB-FEA800M) — 4-3-7-4.Max bridge transmit delay bound diagram (page 36)
Fig. 39 · 4-3-7-4.Max bridge transmit delay bound
<Edit>Configure all items. Finished configure press ESC to go back

Actions->

Page 37 of the Lobos Tech Ethernet Switch (LB-FEA800M) user manual — 4-4-1.STP
Page 37 · click to enlarge
Page 37

action menu line.

<Save>: Save all configure value.

<Quit>: Exit this page and return to previous menu.

4-4.Protocol Related Configuration

4-4-1.STP

Lobos Tech Ethernet Switch (LB-FEA800M) — 4-4-1.STP diagram (page 37)
Fig. 40

4-4-1-1.STP Enable

This page is enable or disable Spanning Tree function. Press Space

key to select enable or disable.

Page 38 of the Lobos Tech Ethernet Switch (LB-FEA800M) user manual — 4-4-1-2.System Configuration
Page 38 · click to enlarge
Page 38
Lobos Tech Ethernet Switch (LB-FEA800M) — 4-4-1-2.System Configuration diagram (page 38)
Fig. 41 · 4-4-1-2.System Configuration

4-4-1-2.System Configuration

Lobos Tech Ethernet Switch (LB-FEA800M) — 4-4-1-2.System Configuration diagram (page 38)
Fig. 42 · 4-4-1-2.System Configuration

1.You can view spanning tree information about the Root Bridge on the

left.

2.On the right, user can setting new value for STP parameter.

Page 39 of the Lobos Tech Ethernet Switch (LB-FEA800M) user manual — 4-4-1-3.Perport Configuration
Page 39 · click to enlarge
Page 39

4-4-1-3.Perport Configuration

Lobos Tech Ethernet Switch (LB-FEA800M) — 4-4-1-3.Perport Configuration diagram (page 39)
Fig. 43 · 4-4-1-3.Perport Configuration
1. PortState: You can view spanning tree status about the switch for per

port.

2. PathCost: Specifies the path cost of the port that switch uses to

determine which port are the forwarding ports. If you change the value,

you need to restart the switch for valid value.

3. Priority: This is mean port priority; you can make it more or less likely

to become the root port. If you change the value, you need to restart the

switch for valid value.

Page 40 of the Lobos Tech Ethernet Switch (LB-FEA800M) user manual — 4-4-2-1.System Options
Page 40 · click to enlarge
Page 40

4-4-2.SNMP

Use this page to define management stations as trap managers and to

enter SNMP community strings. User can also define a name, location,

and contact person for the switch.

Lobos Tech Ethernet Switch (LB-FEA800M) — 4-4-2.SNMP diagram (page 40)
Fig. 44

4-4-2-1.System Options

Lobos Tech Ethernet Switch (LB-FEA800M) — 4-4-2-1.System Options diagram (page 40)
Fig. 45 · 4-4-2-1.System Options

Press <Edit> to enter all items, and then press <Save> to save

configure value.

Page 41 of the Lobos Tech Ethernet Switch (LB-FEA800M) user manual — 4-4-2.SNMP
Page 41 · click to enlarge
Page 41
1. System Name: Type a name to be used for the switch.
2. System Contact: Type the name of contact person or organization.
3. System Location: Type the location of the switch.

4-4-2-2.Community Strings

Use this page to enter SNMP community strings.

1.Community Name: Type the name of current strings.

2.Write Access: Enable the rights is read only or read/write.

Read onlyRead only, enables requests accompanied by this string to

display MIB-object information.

Read/WriteRead write, enables requests accompanied by this string to

display MIB-object information and to set MIB objects.

Lobos Tech Ethernet Switch (LB-FEA800M) — 4-4-2.SNMP diagram (page 41)
Fig. 46
Page 42 of the Lobos Tech Ethernet Switch (LB-FEA800M) user manual — 4-4-2-3.Trap Managers
Page 42 · click to enlarge
Page 42
Lobos Tech Ethernet Switch (LB-FEA800M) — 4-4-2-3.Trap Managers diagram (page 42)
Fig. 47 · 4-4-2-3.Trap Managers

<Add>: Create a community strings.

<Edit>Modify all items. Finished configure press ESC to go back

action menu line.

<Delete>Delete a community strings. After delete item press <Save>

to complete the deleting operation.

<Save>: Save all configure value.

<Quit>: Exit this page and return to previous menu.

4-4-2-3.Trap Managers

A trap manager is a management station that receives traps, the system

alerts generated by the switch. If no trap manager is defined, no traps

are issued. Create a trap manager by entering the IP address of the

station and a community string.

Actions->

Page 43 of the Lobos Tech Ethernet Switch (LB-FEA800M) user manual — 4-4-2-3.Trap Managers
Page 43 · click to enlarge
Page 43
Lobos Tech Ethernet Switch (LB-FEA800M) — 4-4-2-3.Trap Managers diagram (page 43)
Fig. 48 · 4-4-2-3.Trap Managers
Lobos Tech Ethernet Switch (LB-FEA800M) — 4-4-2-3.Trap Managers diagram (page 43)
Fig. 49 · 4-4-2-3.Trap Managers

<Add>: Create a trap manager.

<Edit>Modify all items. Finished configure press ESC to go back

action menu line.

<Delete>Delete a trap manager. After delete item press <Save> to

Actions->

Page 44 of the Lobos Tech Ethernet Switch (LB-FEA800M) user manual — 4-4-3.GVRP
Page 44 · click to enlarge
Page 44

complete the deleting operation.

<Save>: Save all configure value.

<Quit>: Exit this page and return to previous menu.

4-4-3.GVRP

This page you can enable / disable the GVRP (GARP VLAN

Registration Protocol) support.

Press Space key to choose Enabled / Disabled.

Lobos Tech Ethernet Switch (LB-FEA800M) — 4-4-3.GVRP diagram (page 44)
Fig. 50
<Edit>Configure all items. Press Space key to choose Enable or

Disabled mode. Finished configure press ESC to go back action menu

line.

<Save>: Save all configure value.

<Quit>: Exit this page and return to previous menu.

Actions->

Page 45 of the Lobos Tech Ethernet Switch (LB-FEA800M) user manual — 4-4-4-1.Aggregator Setting
Page 45 · click to enlarge
Page 45

4-4-4.LACP

Lobos Tech Ethernet Switch (LB-FEA800M) — 4-4-4.LACP diagram (page 45)
Fig. 51

4-4-4-1.Aggregator Setting

1.Group: Display the trunk group ID.

2.LACPPress Space key to enable or disable LACP (Link Aggregation

Control Protocol) support. If enable, the group is LACP static trunking

group. If disable, the group is local static trunking group.

3.LACP Work Port NumThe max number of ports can be aggregated

at the same time. If LACP static trunking group, the exceed ports is

standby and able to aggregate if work ports fail. If local static trunking

group, the number must be the same as group ports.

page of Port / Trunk Configuration first.

Page 46 of the Lobos Tech Ethernet Switch (LB-FEA800M) user manual — 4-4-4-2.State Activity
Page 46 · click to enlarge
Page 46
Lobos Tech Ethernet Switch (LB-FEA800M) — 4-4-4-2.State Activity diagram (page 46)
Fig. 52 · 4-4-4-2.State Activity
<Edit>Configure all items. Finished configure press ESC to go back

action menu line.

<Save>: Save all configure value.

<Quit>: Exit this page and return to previous menu.

4-4-4-2.State Activity

Active: The port automatically sends LACP protocol packets.

PassiveThe port does not automatically sends LACP protocol packets,

and responds only if it receives LACP protocol packets from the

opposite device.

Actions->

Page 47 of the Lobos Tech Ethernet Switch (LB-FEA800M) user manual — 4-4-4-3.LACP Status
Page 47 · click to enlarge
Page 47
Lobos Tech Ethernet Switch (LB-FEA800M) — 4-4-4-3.LACP Status diagram (page 47)
Fig. 53 · 4-4-4-3.LACP Status
<Edit>Configure all items. Finished configure press ESC to go back

action menu line.

<Save>: Save all configure value.

<Quit>: Exit this page and return to previous menu.

4-4-4-3.LACP Status

When you setting trunking group, you can see relation information in

here.

Actions->

Page 48 of the Lobos Tech Ethernet Switch (LB-FEA800M) user manual — 4-4-4-3.LACP Status
Page 48 · click to enlarge
Page 48
Lobos Tech Ethernet Switch (LB-FEA800M) — 4-4-4-3.LACP Status diagram (page 48)
Fig. 54 · 4-4-4-3.LACP Status

<Quit>: Exit this page and return to previous menu.

<Previous Page>: Return to previous page to view.

<Next page>: Go to next page to view.

4-5.Reboot Switch

Default: Reset switch to default configuration.

Restart: Reboot the switch in software reset.

Actions->

Page 49 of the Lobos Tech Ethernet Switch (LB-FEA800M) user manual — 4-4-4-3.LACP Status
Page 49 · click to enlarge
Page 49
Lobos Tech Ethernet Switch (LB-FEA800M) — 4-4-4-3.LACP Status diagram (page 49)
Fig. 55 · 4-4-4-3.LACP Status

4-6. X-modem Upgrade

1.Press X key to start upgrading for X-modem.

1. First, disconnect terminal and modify baud rate to 57600bps, then do

the connection again.

Lobos Tech Ethernet Switch (LB-FEA800M) — 4-4-4-3.LACP Status diagram (page 49)
Fig. 56 · 4-4-4-3.LACP Status
Lobos Tech Ethernet Switch (LB-FEA800M) — 4-4-4-3.LACP Status diagram (page 49)
Fig. 57 · 4-4-4-3.LACP Status

3.Select “send file" under "transfer" menu from menu bar.

4.Press "browse" button to select the path.

Page 50 of the Lobos Tech Ethernet Switch (LB-FEA800M) user manual — 4-4-4-3.LACP Status
Page 50 · click to enlarge
Page 50

5.Select "1K X-modem" of protocol and press "Send" button.

Lobos Tech Ethernet Switch (LB-FEA800M) — 4-4-4-3.LACP Status diagram (page 50)
Fig. 58 · 4-4-4-3.LACP Status

6.After successfully upgraded the new firmware, please modify baud

rate to 9600bps.

Lobos Tech Ethernet Switch (LB-FEA800M) — 4-4-4-3.LACP Status diagram (page 50)
Fig. 59 · 4-4-4-3.LACP Status
Page 51 of the Lobos Tech Ethernet Switch (LB-FEA800M) user manual — Web-Based Management
Page 51 · click to enlarge
Page 51

Web-Based Management

This section introduces the configuration and functions of the Web-based management of 8TP+ 1Fiber Management Switch series. The 8TP+ 1Fiber Management Switch series provides an embedded

HTML website residing in flash memory. It offers management feature

and allows users to manage the 8TP+1Fiber Management Switch from

anywhere on the network through a standard Web Browser.

function, the web management function will have unexpected

display if the IE version is below version 5.5. Web Management Function

1. Web Management Function provides a Web browser to manage and

monitor the switch, the default values as follows:

If you need change IP address in first time, you can use console mode

to modify it.

IP Address192.168.16.1
Subnet Mask255.255.255.0

Default Gateway:192.168.16.254

User Nameroot
Passwordroot
2. You can browse http://192.168.16.1 type user name and password
Page 52 of the Lobos Tech Ethernet Switch (LB-FEA800M) user manual — 5-2. Port status
Page 52 · click to enlarge
Page 52

as above.

Lobos Tech Ethernet Switch (LB-FEA800M) — 5-2. Port status diagram (page 52)
Fig. 60 · 5-2. Port status

5-1. Web Management Home Overview (The image was

captured from 8TP + 100FX)

1. Home Page.
Lobos Tech Ethernet Switch (LB-FEA800M) — 5-2. Port status diagram (page 52)
Fig. 61 · 5-2. Port status

5-2. Port status

1. port status

StateDisplay port status off or on depended on user setting. “unlink”

will be treated as “off ”.

Link StatusDown is “No Link”, UP is “Link”
Auto Negotiationauto negotiation mode
Speed statusDisplay 100Mbps or 10Mbps speed, Port 18 is

10/100Mbps, Port 9 is 100 Mbps.

Duplex status: Display full-duplex or half-duplex mode.

Flow controlDisplay flow control status enable or disable mode

Config: Display the state of user setting.

Atual: Display the negotiation result.

Page 53 of the Lobos Tech Ethernet Switch (LB-FEA800M) user manual — 5-2. Port status
Page 53 · click to enlarge
Page 53
Lobos Tech Ethernet Switch (LB-FEA800M) — 5-2. Port status diagram (page 53)
Fig. 62 · 5-2. Port status

User can see a single port counter as follows

Lobos Tech Ethernet Switch (LB-FEA800M) — 5-2. Port status diagram (page 53)
Fig. 63 · 5-2. Port status

5-3. Port Statistics

1. The following information provides a view of the current status of the

unit.

Page 54 of the Lobos Tech Ethernet Switch (LB-FEA800M) user manual — 5-4-1. IP Address
Page 54 · click to enlarge
Page 54

5-4. Administrator

Those management functions include:

IP address, Switch settings, Console port information, Port controls

Link aggregation, Filter database, VLAN configuration ,Spanning

Tree, Port Mirror, SNMP, Security Manager, TFTP Update Firmware

Configuration Backup, Reset system and Reboot.

5-4-1. IP Address

1. User can configure the IP Settings and fill in the new value, than

clicks apply button.

2. User must be reset switch and use new IP address to browser this

web management.

Page 55 of the Lobos Tech Ethernet Switch (LB-FEA800M) user manual — 5-4-2. Switch Setting
Page 55 · click to enlarge
Page 55
Lobos Tech Ethernet Switch (LB-FEA800M) — 5-4-2. Switch Setting diagram (page 55)
Fig. 64 · 5-4-2. Switch Setting

5-4-2. Switch Setting

5-4-2-1.Basic

1. Description: Display the name of device type.
2. MAC Address: The unique hardware address assigned by
3. Firmware Version: Display the switch’s firmware version.
4. Hardware Version: Display the switch’s Hardware version.
5. Default configure value version: Display write to default

EEPROM value version.

manufacturer (default)

Page 56 of the Lobos Tech Ethernet Switch (LB-FEA800M) user manual — 5-4-2-2.Advanced
Page 56 · click to enlarge
Page 56
Lobos Tech Ethernet Switch (LB-FEA800M) — 5-4-2-2.Advanced diagram (page 56)
Fig. 65 · 5-4-2-2.Advanced

5-4-2-2.Advanced

Miscellaneous Setting :

MAC Address Age-out TimeType the number of seconds that an

inactive MAC address remains in the switch's address table. The valid

range is 300~765 seconds. Default is 300 seconds.

Max bridge transit delay bound control: Limit the packets queuing

time in switch. If enable, the packets queued exceed will be drop. This

valid value are 1sec, 2 sec, 4 sec and off. Default is 1 seconds.

Broadcast Storm FilterTo configure broadcast storm control, enable it

and set the upper threshold for individual

ports. The threshold is the percentage of the port's total bandwidth used

by broadcast traffic. When broadcast traffic for a port rises above the

threshold you set, broadcast storm control becomes active. The valid

threshold value are 5%, 10%, 15%, 20%, 25% and off.

Page 57 of the Lobos Tech Ethernet Switch (LB-FEA800M) user manual — 5-4-2-2.Advanced
Page 57 · click to enlarge
Page 57
Lobos Tech Ethernet Switch (LB-FEA800M) — 5-4-2-2.Advanced diagram (page 57)
Fig. 66 · 5-4-2-2.Advanced

Priority Queue Service settings:

First Come First ServiceThe sequence of packets sent is depend on

arrive order.

All High before LowThe high priority packets sent before low priority

packets.

Weighted Round RobinSelect the preference given to packets in the

switch's high-priority queue.

These options represent the number of high priority packets sent before

one low priority packet is sent. For example, 2 High :1 Low means that

the switch sends 2 high priority packets before sending 1 low priority

packet.

Enable Delay BoundLimit the low priority packets queuing time in

switch. Default Max Delay Time is 255ms.

If the low priority packet stays in switch exceed Max Delay Time, it will

be sent. The valid range is 1~255 ms.

before enable Delay Bound, because Enable Delay Bound must be

work under “Max bridge transit delay bound control is enabled” situation.

Page 58 of the Lobos Tech Ethernet Switch (LB-FEA800M) user manual — 5-4-2-2.Advanced
Page 58 · click to enlarge
Page 58
Qos PolicyHigh Priority Levels: 0~7 priority level can map to high or

low queue. When the VLAN Tag number of a frame is mapping the

priority level of the port, and this frame can have high priority.(This QoS

Policy is for global Switch, not for any single port)

Lobos Tech Ethernet Switch (LB-FEA800M) — 5-4-2-2.Advanced diagram (page 58)
Fig. 67 · 5-4-2-2.Advanced

Protocol Enable Setting :

Enable Spanning Tree ProtocolDefault recommend to enable STP
Enable Internet Group Multicast Protocolenable IGMP protocol
IGMP Query ModeRecognize different Query from client or server to

decide which Queryer will be the first priority, they are three mode as

follow:

1. Auto Mode : Choose the indicated Switch, which has the smallest IP

address will be set for the IGMP Queryer.

2. Enable Mode : Enable one of Switch to be the IGMP Queryer.
3. Disable Mode : Disable the other Switches to be the IGMP Queryer.
Lobos Tech Ethernet Switch (LB-FEA800M) — 5-4-2-2.Advanced diagram (page 58)
Fig. 68 · 5-4-2-2.Advanced

VLAN Operation Mode:

Page 59 of the Lobos Tech Ethernet Switch (LB-FEA800M) user manual — 5-4-2-2.Advanced
Page 59 · click to enlarge
Page 59

802.1Q(Tag VLAN) without GVRP VLAN mode

802.1Q(Tag VLAN) with GVRP VLAN mode (Default)

Also, three kind of typologies shown as below indicate how the IGMP

Query work within a network:

1. This topology has to be set for when the router’s IP address is

smaller than other Switch in subnet.

Lobos Tech Ethernet Switch (LB-FEA800M) — 5-4-2-2.Advanced diagram (page 59)
Fig. 69 · 5-4-2-2.Advanced
2. This topology has to be set for when the router’s IP address is not

smaller than other Switch in subnet.

No VLAN · Port Based

Page 60 of the Lobos Tech Ethernet Switch (LB-FEA800M) user manual — 5-4-2-2.Advanced
Page 60 · click to enlarge
Page 60
Lobos Tech Ethernet Switch (LB-FEA800M) — 5-4-2-2.Advanced diagram (page 60)
Fig. 70 · 5-4-2-2.Advanced

in enable mode, and the Router has to be the Queryer.

3. This topology must be set for when the Switch’s IP address is not the

smallest in the subnet. If in Auto mode, the network will cause multi-cast

storm from the client IGMP report, the topology shown as below is

necessary to be set for.

Page 61 of the Lobos Tech Ethernet Switch (LB-FEA800M) user manual — 5-4-3. Console Port Information
Page 61 · click to enlarge
Page 61
Lobos Tech Ethernet Switch (LB-FEA800M) — 5-4-3. Console Port Information diagram (page 61)
Fig. 71 · 5-4-3. Console Port Information
4. All of Switch must be in Disable mode, When VOD server is set up for

IGMP Queryer.

GVRP (GARP [Generic Attribute Registration Protocol] VLAN

GVRP allows automatic VLAN configuration between the switch and

nodes. If the switch is connected to a device with GVRP enabled, you

can send a GVRP request using the VID of a VLAN defined on the

switch, the switch will automatically add that device to the existing

VLAN.

5-4-3. Console Port Information

1. Console is a standard UART interface to communicate with Serial

Port.

User can use windows HyperTerminal program to link the switch.

Baud rate (bits/sec):

Data bits8
Parity checknone

Registration Protocol) · Connect To->Configure

Page 62 of the Lobos Tech Ethernet Switch (LB-FEA800M) user manual — 5-4-4. Port Controls
Page 62 · click to enlarge
Page 62
Lobos Tech Ethernet Switch (LB-FEA800M) — 5-4-4. Port Controls diagram (page 62)
Fig. 72 · 5-4-4. Port Controls

5-4-4. Port Controls

1. This page can Change every port status
StateUser can disable or enable this port control
Auto NegotiationUser can set auto negotiation is enable or disable of
Speed settingUser can set 100Mbps or 10Mbps speed (Port1~Port8)
Duplex settingUser can set full-duplex or half-duplex mode
Flows control settingUser can set flow control function is enable or

per port · disable

Page 63 of the Lobos Tech Ethernet Switch (LB-FEA800M) user manual — 5-4-5. Trunking
Page 63 · click to enlarge
Page 63
Lobos Tech Ethernet Switch (LB-FEA800M) — 5-4-5. Trunking diagram (page 63)
Fig. 73 · 5-4-5. Trunking

5-4-5. Trunking

The Trunking provides a standardized means for exchanging

between Partner Systems on a link to allow their Link Aggregation

Control instances to reach agreement on the identity of the Link

Aggregation Group to which the link belongs, move the link to that Link

Group, and enable its transmission and reception functions in an orderly

manner. In conclusion, Link aggregation lets you group up to eight

consecutive ports into a single dedicated connection. This feature can

expand bandwidth to a device on the network. LACP operation

requires full-duplex mode, more detail information refer to IEEE

802.3ad.

5-4-5-1. Aggregator setting

System PriorityA value used to identify the active LACP. The switch

information · Aggregation

Page 64 of the Lobos Tech Ethernet Switch (LB-FEA800M) user manual — 5-4-5. Trunking
Page 64 · click to enlarge
Page 64

with the lowest value has the highest priority and is selected as the

active LACP.

Lobos Tech Ethernet Switch (LB-FEA800M) — 5-4-5. Trunking diagram (page 64)
Fig. 74 · 5-4-5. Trunking
1.Group IDyou can create a link aggregation across two or more ports,

choose the "group id" and click "Get".

2.LACPIf enable, the group is LACP static trunking group. If disable,

the group is local static trunking group.

All ports support LACP dynamic trunking group. If connecting to the

device that also supports LACP, the LACP dynamic trunking group will

be created automatically.

3. Work ports: The max number of ports can be aggregated at the same

time. If LACP static trunking group, the exceed ports is standby and able

to aggreate if work ports fail. If local static trunking group, the number

must be the same as group ports.

4. Select the ports to join the trunking group
5. If LACP enable, you can configure LACP Active/Passive status in

each ports.

6. Click Apply.
Page 65 of the Lobos Tech Ethernet Switch (LB-FEA800M) user manual — 5-4-5-3. State Activity
Page 65 · click to enlarge
Page 65

5-4-5-2. Aggregator Information

When you are setting LACP aggregator, you can see relation

information in here.

Lobos Tech Ethernet Switch (LB-FEA800M) — 5-4-5-2. Aggregator Information diagram (page 65)
Fig. 75 · 5-4-5-2. Aggregator Information

5-4-5-3. State Activity

Active (select): The port automatically sends LACP protocol packets.

Passive (no select)The port does not automatically sends LACP

protocol packets, and responds only if it receives LACP protocol packets

from the opposite device.

1. A link having either two active LACP ports or one active port can
Page 66 of the Lobos Tech Ethernet Switch (LB-FEA800M) user manual — 5-4-5-2. Aggregator Information
Page 66 · click to enlarge
Page 66

perform dynamic LACP trunking.

A link has two passive LACP ports will not perform dynamic LACP

trunking because both ports are waiting for and LACP protocol packet

from the opposite device.

2. If you are active LACP’s actor, when you are select trunking port, the

active status will be created automatically.

Lobos Tech Ethernet Switch (LB-FEA800M) — 5-4-5-2. Aggregator Information diagram (page 66)
Fig. 76 · 5-4-5-2. Aggregator Information
Page 67 of the Lobos Tech Ethernet Switch (LB-FEA800M) user manual — 5-4-6. Filter Database
Page 67 · click to enlarge
Page 67

5-4-6. Filter Database

5-4-6-1. IGMP Snooping

Lobos Tech Ethernet Switch (LB-FEA800M) — 5-4-6. Filter Database diagram (page 67)
Fig. 77 · 5-4-6. Filter Database

The 8TP+1Fiber Management Switch support IP multicast , you can

enable IGMP protocol on web management’s switch setting advanced

page, then display the IGMP snooping information in this page, you can

view difference multicast group ,VID and member port in here, IP

multicast addresses range from 224.0.0.0 through 239.255.255.255.

The Internet Group Management Protocol (IGMP) is an internal protocol

of the Internet Protocol (IP) suite.

IP manages multicast traffic by using switches, routers, and hosts that

support IGMP. Enabling IGMP allows the ports to detect IGMP queries

and report packets and manage IP multicast traffic through the switch.

IGMP have three fundamental types of message as follows:

Page 68 of the Lobos Tech Ethernet Switch (LB-FEA800M) user manual — 5-4-6-2. Static MAC Address
Page 68 · click to enlarge
Page 68

A message sent from the querier (IGMP router or switch) asking for a

response from each host belonging to the multicast group.

A message sent by a host to the querier to indicate that the host wants

to be or is a member of a given group indicated in the report message.

A message sent by a host to the querier to indicate that the host has quit to

be a member of a specific multicast group.

5-4-6-2. Static MAC Address

Lobos Tech Ethernet Switch (LB-FEA800M) — 5-4-6-2. Static MAC Address diagram (page 68)
Fig. 78 · 5-4-6-2. Static MAC Address

When you add a static MAC address, it remains in the switch's address

table, regardless of whether the device is physically connected to the

switch. This saves the switch from having to re-learn a device's MAC

address when the disconnected or powered-off device is active on the

network again.

1. To add a static MAC address
2. From the main menu, click administrator, then click Filter Database.
Show 12 more labels / short text on this page
Mes · Description · sag · e · Que · ry · Rep · ort · Lea · ve · Gro · up
Page 69 of the Lobos Tech Ethernet Switch (LB-FEA800M) user manual — 5-4-6-4. MAC Filtering
Page 69 · click to enlarge
Page 69
3. Click Static MAC Addresses. In the MAC address box, enter the MAC

address to and from which the port should permanently forward traffic,

regardless of the device's network activity.

4. In the Port Number box, select a port number.
5. If tag-based (IEEE 802.1Q) VLANs are set up on the switch, static

addresses are associated with individual VLANs. Type the VID

(tag-based VLANs) to associate with the MAC address.

6. Click add

5-4-6-3. Port Security

A port in security mode will be “locked” without permission of address

learning. Only the incoming packets with SMAC already existing in the

address table can be forwarded normally. User can disable the port from

learning any new MAC addresses, then use the static MAC addresses

screen to define a list of MAC addresses that can use the secure port.

Enter the settings, then click Submit to apply the changes on this page.

Lobos Tech Ethernet Switch (LB-FEA800M) — 5-4-6-3. Port Security diagram (page 69)
Fig. 79 · 5-4-6-3. Port Security

5-4-6-4. MAC Filtering

Page 70 of the Lobos Tech Ethernet Switch (LB-FEA800M) user manual — 5-4-7. VLAN configuration
Page 70 · click to enlarge
Page 70
Lobos Tech Ethernet Switch (LB-FEA800M) — 5-4-7. VLAN configuration diagram (page 70)
Fig. 80 · 5-4-7. VLAN configuration

5-4-7. VLAN configuration

A Virtual LAN (VLAN) is a logical network grouping that limits the

broadcast domain. It allows you to isolate network traffic so only

members of the VLAN receive traffic from the same VLAN members.

Basically, creating a VLAN from a switch is logically equivalent of

reconnecting a group of network devices to another Layer 2 switch.

However, all the network devices are still plug into the same switch

physically.

The 8TP+1Fiber Management Switch support port-based and

protocol-base VLAN in web management page, In the default

VLAN support is enable and all ports on the switch belong to default

VLAN, VID is 1.

configuration,

Page 71 of the Lobos Tech Ethernet Switch (LB-FEA800M) user manual — 5-4-7-1. Basic
Page 71 · click to enlarge
Page 71

Support Port-based VLANs (IEEE 802.1Q VLAN)

Port-based Tagging rule VLAN is an IEEE 802.1Q specification

standard. Therefore, it is possible to create a VLAN across devices from

different switch venders. IEEE 802.1Q VLAN uses a technique to insert

a “tag” into the Ethernet frames. Tag contains a VLAN Identifier (VID)

that indicates the VLAN numbers.

In order for an end station to send packets to different VLANs, it itself

has to be either capable of tagging packets it sends with VLAN tags or

attached to a VLAN-aware bridge that is capable of classifying and

tagging the packet with different VLAN ID based on not only default

PVID but also other information about the packet, such as the protocol.

5-4-7-1. Basic

Lobos Tech Ethernet Switch (LB-FEA800M) — 5-4-7-1. Basic diagram (page 71)
Fig. 81 · 5-4-7-1. Basic

Create a VLAN and add tagged member ports to it.

1. From the main menu, click administrator -- VLAN configuration.
2. Click Add
3. Type a name for the new VLAN.
4. Type a VID (between 2-4094). The default is 1.

Support Protocol-based VLAN

Page 72 of the Lobos Tech Ethernet Switch (LB-FEA800M) user manual — 5-4-7-1. Basic
Page 72 · click to enlarge
Page 72
5. From the Available ports box, select ports to add to the switch and

click Add.

6. Click Apply

5-4-7-2. Port VID

Configure port VID settings

From the main Tag-based (IEEE 802.1Q) VLAN page, click Port VID

Settings.

Sets the Port VLAN ID that will be assigned to untagged traffic on a

given port. For example, if port 9's Default PVID is 100, all untagged

packets on port 9 will belong to VLAN 100. The default setting for all

ports is VID 1.

This feature is useful for accommodating devices that you want to

participate in the VLAN but that don't support tagging. Only one

untagged VLAN is allowed per port.

Lobos Tech Ethernet Switch (LB-FEA800M) — 5-4-7-1. Basic diagram (page 72)
Fig. 82 · 5-4-7-1. Basic

Ingress filtering lets frames belonging to a specific VLAN to be

forwarded if the port belongs to that VLAN. 8TP+1Fiber Management

Switch have two ingress filtering rule as follows:

Ingress Filtering Rule 1Forward only packets with VID matching this

Port VID (PVID) · Ingress Filtering

Page 73 of the Lobos Tech Ethernet Switch (LB-FEA800M) user manual — 5-4-8. Spanning Tree
Page 73 · click to enlarge
Page 73

port's configured VID .

Ingress Filtering Rule 2: Drop Untagged Frame.

5-4-8. Spanning Tree

The Spanning-Tree Protocol (STP) is a standardized method (IEEE

802.1D ) for avoiding loops in switched networks. When STP enabled,

to ensure that only one path at a time is active between any two nodes

on the network.

You can enable Spanning-Tree Protocol on web management’s switch

setting advanced item, select enable Spanning-Tree protocol. We are

recommended that you enable STP on all switches ensures a single

active path on the network.

1. You can view spanning tree information about the Root Bridge.

Such as follow screen.

Lobos Tech Ethernet Switch (LB-FEA800M) — 5-4-8. Spanning Tree diagram (page 73)
Fig. 83 · 5-4-8. Spanning Tree
2. You can view spanning tree status about the switch. Such as

follow screen.

Page 74 of the Lobos Tech Ethernet Switch (LB-FEA800M) user manual — 5-4-8. Spanning Tree
Page 74 · click to enlarge
Page 74
Lobos Tech Ethernet Switch (LB-FEA800M) — 5-4-8. Spanning Tree diagram (page 74)
Fig. 84 · 5-4-8. Spanning Tree
Lobos Tech Ethernet Switch (LB-FEA800M) — 5-4-8. Spanning Tree diagram (page 74)
Fig. 85 · 5-4-8. Spanning Tree

You can change priority value, A value used to identify the root

bridge. The bridge with the lowest value has the highest priority and is

selected as the root. Enter a number 1 through 65535.

Max Age You can change Max Age value, The number of seconds a bridge

waits without receiving Spanning-Tree Protocol configuration

messages before attempting a reconfiguration. Enter a number 6

through 40.

You can change Hello time value, the number of seconds between

the transmission of Spanning-Tree Protocol configuration messages.

Enter a number 1 through 10.

You can change forward delay time, The number of seconds a port

waits before changing from its Spanning-Tree Protocol learning and

listening states to the forwarding state. Enter a number 4 through 30.

3. The following parameter can be configured on each port , click

set Apply button to modify .

Show 7 more labels / short text on this page
Prameter Description · Priority · Hello · Time · Forward · Delay · time
Page 75 of the Lobos Tech Ethernet Switch (LB-FEA800M) user manual — 5-4-8. Spanning Tree
Page 75 · click to enlarge
Page 75
Lobos Tech Ethernet Switch (LB-FEA800M) — 5-4-8. Spanning Tree diagram (page 75)
Fig. 86 · 5-4-8. Spanning Tree

You can make it more or less likely to become the root port, the

rage is 0-255,default setting is 128

the lowest number has the highest priority. If you change the value,

you must reboot the switch.

Specifies the path cost of the port that switch uses to determine

which port are the forwarding ports

the lowest number is forwarding ports, the rage is 1-65535

and default value base on IEEE802.1D

10Mb/s = 50-600 100Mb/s = 10-60

If you change the value, you must reboot the switch. 5-4-9. Port Mirror

The Port Mirror is a method for monitor traffic in switched networks.

Traffic through ports can be monitored by one specific port. That is,

traffic goes in or out monitored ports will be duplicated into mirror port.

Show 14 more labels / short text on this page
Par · Description · am · ete · r · Por · t · Pri · orit · y · Pat · h · Co · st
Page 76 of the Lobos Tech Ethernet Switch (LB-FEA800M) user manual — 5-4-10. SNMP
Page 76 · click to enlarge
Page 76
Lobos Tech Ethernet Switch (LB-FEA800M) — 5-4-10. SNMP diagram (page 76)
Fig. 87

Roving Analysis State: Enable or disable the port mirror function.

Mirror PortsThe ports you want to mirror. All mirror port traffic will be

copied to mirror port. You can select max 9 monitor ports in the switch. If

you want to disable the function, you must select monitor port to none.

Monitor Rx: Monitored receive frames from the port.

Monitor Tx: Monitored send frames from the port.

5-4-10. SNMP

Any Network Management running the simple Network Management

Protocol (SNMP) can management the switch,

Provided the Management Information Base (MIB) is installed correctly

on the management station. The SNMP is a Protocol that governs the

transfer of information between management and agent. The

8TP+1Fiber Management Switch supports SNMP V1.

1. Use this page to define management stations as trap managers and to

enter SNMP community strings. User can also define a name, location,

and contact person for the switch. Fill in the system options data, then

click Apply to update the changes on this page

Page 77 of the Lobos Tech Ethernet Switch (LB-FEA800M) user manual — 5-4-10. SNMP
Page 77 · click to enlarge
Page 77

Name: Enter a name to be used for the switch.

Location: Enter the location of the switch.

Contact: Enter the name of a person or organization.

Lobos Tech Ethernet Switch (LB-FEA800M) — 5-4-10. SNMP diagram (page 77)
Fig. 88
2. Community strings serve as passwords and can be entered as

one of the following:

Read onlyEnables requests accompanied by this string to display

MIB-object information.

Read writeEnables requests accompanied by this string to display

MIB-object information and to set MIB objects.

3. Trap Manager

A trap manager is a management station that receives traps, the system

alerts generated by the switch. If no trap manager is defined, no traps

are issued. Create a trap manager by entering the IP address of the

station and a community string.

Page 78 of the Lobos Tech Ethernet Switch (LB-FEA800M) user manual — 5-4-12. TFTP Update Firmware
Page 78 · click to enlarge
Page 78
Lobos Tech Ethernet Switch (LB-FEA800M) — 5-4-11.Security Manager diagram (page 78)
Fig. 89 · 5-4-11.Security Manager

5-4-11.Security Manager

1. Use this page, user can change web management user name and

password.

User nameroot
Passwordroot
Lobos Tech Ethernet Switch (LB-FEA800M) — 5-4-11.Security Manager diagram (page 78)
Fig. 90 · 5-4-11.Security Manager

5-4-12. TFTP Update Firmware

1. The following menu options provide some system control

functions to allow a user to update

firmware and remote boot switch system:

Page 79 of the Lobos Tech Ethernet Switch (LB-FEA800M) user manual — 5-4-13-2. TFTP Backup Configuration
Page 79 · click to enlarge
Page 79

* Executing TFTP software

* Copy firmware update version image.bin to TFTP software directory.

* In web management select administrator— TFTP update firmware.

* Download new image.bin file then in web management press

firmware>.

Lobos Tech Ethernet Switch (LB-FEA800M) — 5-4-13. Configuration Backup diagram (page 79)
Fig. 91 · 5-4-13. Configuration Backup

5-4-13. Configuration Backup

5-4-13-1. TFTP Restore Configuration

Use this page to set TFTP server address. You can restore EEPROM

value from here, but you must put back image in TFTP server, switch

will download back flash image.

Lobos Tech Ethernet Switch (LB-FEA800M) — 5-4-13. Configuration Backup diagram (page 79)
Fig. 92 · 5-4-13. Configuration Backup

5-4-13-2. TFTP Backup Configuration

Use this page to set TFTP server IP address. You can save current

EEPROM value from here, then go to the TFTP restore configuration

Page 80 of the Lobos Tech Ethernet Switch (LB-FEA800M) user manual — 5-4-13. Configuration Backup
Page 80 · click to enlarge
Page 80

page to restore the EEPROM value.

Lobos Tech Ethernet Switch (LB-FEA800M) — 5-4-13. Configuration Backup diagram (page 80)
Fig. 93 · 5-4-13. Configuration Backup
Page 81 of the Lobos Tech Ethernet Switch (LB-FEA800M) user manual — 5-4-15. Reboot
Page 81 · click to enlarge
Page 81

5 -4-14. Reset System

Reset Switch to default configuration, default value as below

Lobos Tech Ethernet Switch (LB-FEA800M) — 5 -4-14. Reset System diagram (page 81)
Fig. 94 · 5 -4-14. Reset System

5-4-15. Reboot

Reboot the Switch in software reset.

Lobos Tech Ethernet Switch (LB-FEA800M) — 5-4-15. Reboot diagram (page 81)
Fig. 95 · 5-4-15. Reboot
Page 82 of the Lobos Tech Ethernet Switch (LB-FEA800M) user manual — 6. Technical Specifications
Page 82 · click to enlarge
Page 82

6. Technical Specifications

This section provides the specifications of the LB-FEA800M and the following

table lists the specifications.

Lobos Tech Ethernet Switch (LB-FEA800M) — 6. Technical Specifications diagram (page 82)
Fig. 96 · 6. Technical Specifications

Dimensions 250mm x 133mm x 37mm (L x W x H)

Storage Temp. -40℃ to 70 ℃, Non condensing

Page 83 of the Lobos Tech Ethernet Switch (LB-FEA800M) user manual — 6. Technical Specifications
Page 83 · click to enlarge
Page 83

Operational Temp. 0℃ ~ 50℃

Power Supply 100~240VAC, 50/60 Hz

Power Consumption 15 Watts

EMI & Safety FCC A, CE, UL, cUL

Page 84 of the Lobos Tech Ethernet Switch (LB-FEA800M) user manual — Incorrect connections
Page 84 · click to enlarge
Page 84

7. Troubleshooting

This section is intended to help you solve the most common problems on the

LB-FEA800M series.

Incorrect connections

n Faulty or loose cables

Look for loose or obviously faulty connections. If they appear to be OK,

make sure the connections are snug. IF that does not correct the

problem, try a different cable.

Non-standard and miswired cables may cause numerous network

collisions and other network problem, and can seriously impair network

performance. A category 5 cable tester is a recommended tool for every

100Base-T network installation.

n Improper Network Topologies

It is important to make sure that you have a valid network topology.

Common topology faults include excessive cable length and too many

repeaters ( hubs ) between end nodes. In addition, you should make

sure that your network topology contains no data path loops. Between

any two ends nodes, there should be only one active cabling path at any

time. Data path loops will cause broadcast storms that will severely

impact your network performance.

n Non-standard cables

Page 85 of the Lobos Tech Ethernet Switch (LB-FEA800M) user manual — Diagnosing LED Indicators
Page 85 · click to enlarge
Page 85

Diagnosing LED Indicators

The Switch can be easily monitored through panel indicators to assist in

identifying problems, which describes common problems you may

encounter and where you can find possible solutions.

IF the power indicator does not turn on when the power cord is plugged

in, you may have a problem with power outlet, or power cord. However,

if the Switch powers off after running for a while, check for loose power

connections, power losses or surges at power outlet. IF you still cannot

resolve the problem, contact your local dealer for assistance.

RJ-45 portsUse unshielded twisted-pair (UTP) or shield twisted-pair

( STP ) cable for RJ-45 connections: 100Ω Category 3, 4 or 5 cable for

10Mbps connections or 100Ω Category 5 cable for 100Mbps

connections. Also be sure that the length of any twisted-pair connection

does not exceed 100 meters ( 328 feet ).

100Base-FX fiber portFiber multi-mode connector type must use

50/125 or 62.5/125 um multi-mode fiber cable. You can connect two

devices over a 2 kilometer distance. However, Fiber single-mode

connector type must use 9/125 um single- mode fiber cable. You can

connect two devices over a 15~60 kilometers distance in full duplex

operation.

n Cabling

Sources

References & links

Pages referenced in this manual — manufacturer, support and downloads.

Ask about the Lobos Tech Ethernet Switch (LB-FEA800M)

Owners and our team usually reply within a day — and your question helps the next person too.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
No questions yet about the Lobos Tech Ethernet Switch (LB-FEA800M)

Be the first to ask — other owners or our team will answer.

Original document

Lobos Tech Ethernet Switch (LB-FEA800M) manual PDF

85 pages·1.6 MB·Switch·PDF
Click any page above to open it here
Page 1 / …
100%
Loading pages…