EN
Linksys logo
Official user manual

Linksys SFE2010

67 pages·1.6 MB·Switch·PDF·ENDEFRITNLJA
Linksys SFE2010
Table of Contents 58 sections Introduction · Welcome · What’s in this User Guide? · Getting to Know the SFE2010/SFE2010P · … ShowHide
Page 1 of the Linksys SFE2010 user manual — ADMIN GUIDE
Page 1 · click to enlarge
Page 1

ADMIN GUIDE

BUSINESS SERIES

48-port 10/100 Ethernet Switch

Model: SFE2010/SFE2010P

Page 2 of the Linksys SFE2010 user manual — Table of Contents
Page 2 · click to enlarge
Page 2
Linksys SFE2010 diagram (page 2)
Fig. 1

Table of Contents

1 Introduction 1 Welcome 1 What’s in this User Guide? 1 2 Getting to Know the SFE2010/SFE2010P 2 SFE2010/P Front Panel 2 SFE2010/P Back Panel 4 3 Connecting Devices 5 Sample Network Configuration 5 Maximum Cabling Distances 5 Before You Install the Switch... 6 Placement Options 6 Desktop Placement 6 Rack-Mount Placement 7 Wall-Mount Placement 8 Connecting the Cables 8 4 Web Utility Configuration 10 Connecting to the Switch with the Web-Based Utility 10 Using Menus in the Web-Based Utility 10 Viewing On-line Help 11 5 Using the Console 12 Connecting to Your Switch with HyperTerminal 12 Connecting to the Switch with Telnet 15 Logging On to the Console 15 Selecting Menu Options and Actions 15 Using the Switch Main Menu 16 System Configuration 16 System Information 17 Management Settings 19 Username & Password Settings 24 Security Settings 25 VLAN Management 28 IP Configuration 29 File Management 43 Restore System Default Settings 46 Reset to Factory Settings 46 Reboot System 46 Stack Configuration 47 Port Status 47 Port Status 48 PoE Status 48 Port Configuration 49 Port Settings 49 PoE Settings 50 System Mode (Layer 2 / Layer 3) Selection 51 Help 52 Logout 53

SFE2010/SFE2010P Administration Guide i

Page 3 of the Linksys SFE2010 user manual — Table of Contents
Page 3 · click to enlarge
Page 3

Table of Contents

A Contacts 54

US/Canada Contacts 54 B Customer Site Survey 55

C Warranty Information 57

Limited Warranty 57 Exclusions and Limitations 57 Obtaining Warranty Service 58 Technical Support 58 D Federal Communication Commission Interference Statement . . 59

Industry Canada Statement 59 EC Declaration of Conformity (Europe) 59 E Specifications 60

SFE2010/SFE2010P Administration Guide ii

Page 4 of the Linksys SFE2010 user manual — What’s in this User Guide?
Page 4 · click to enlarge
Page 4

Welcome Introduction 1

Introduction

Welcome

Thank you for choosing a Linksys Switch. This Switch will allow you to quickly and economically expand your Linksys system.

This new Linksys rack mount Switch delivers non-blocking, wire speed switching for your network clients, plus multiple options for connecting to your network backbone. Forty eight ports wire up your workstations or connect to other Linksys switches or devices.

The Switch features monitoring and configuration via your web browser, making it easy to manage your Switch. Or if you prefer, you can use the console interface to configure the Switch.

Use the instructions in this guide to help you connect the switch, set it up, and configure it to bridge your different networks. These instructions should be all you need to get the most out of the Switch.

What’s in this User Guide?

This user guide covers the steps for setting up and using the Switch.

  • Chapter 2, "Getting to Know the SFE2010/SFE2010P" This chapter describes the ports, LEDs, and other features on the front and back panels of the switch.
  • Chapter 3, "Connecting Devices " This chapter explains how to physically connect your network devices to the switch.
  • Chapter 4, "Web Utility Configuration " This chapter provides an introduction to the features of the web-based configuration utility.
  • Chapter 5, "Using the Console" This chapter describes the use of the switch console, which allows you to perform basic configuration of the switch.
  • Appendix A, "Contacts"
  • Appendix B, "Customer Site Survey"
  • Appendix C, "Warranty Information"
  • Appendix D, "Federal Communication Commission Interference Statement"
  • Appendix E, "Specifications"
Page 5 of the Linksys SFE2010 user manual — SFE2010/P Front Panel
Page 5 · click to enlarge
Page 5

Getting to Know the SFE2010/SFE2010P 2

Getting to Know the SFE2010/SFE2010P

This chapter describes the ports, LEDs, and other features on the front and back panels of the switch.

The SFE2010 and SFE2010P are 48-port, layer-2 Ethernet switches that affordably expand the capability of the Linksys system. These two versions are functionally identical except the SFE2010P model offers Power-over-Ethernet (PoE) which can be used to supply power to various Linksys products over Ethernet cable.

SFE2010/P Front Panel

FeatureDescription ResetThe Switch can be reset by inserting a pin or paper clip into the RESET opening. CAUTION: If the RESET switch is pressed for more than 10 seconds, the Switch will reset to its default settings. All customized user settings will be lost. LEDsThe Switch uses Light Emitting Diodes (LEDs) to indicate the status of numerous functions. These functions are listed below. PWRA green PWR LED lights up to indicate that the Switch is powered on. FANA green FAN LED lights up to indicate that the cooling fan is operating properly. A blinking red FAN LED indicates that the cooling fan has failed. RPSA green RPS LED lights up to indicate that RPS is connected and operating properly. A blinking red RPS LED indicates an RPS fault. MSTA green MST LED indicates that this Switch is a stack master. Stack IDA green Stack ID LED indicates that this Switch is stacked and the corresponding number indicates its stack ID. Act/LinkThe green Act/Link LEDs light up to indicate a functional network link through the corresponding port with an attached device. The Act (Activity) LEDs flash to indicate that the Switch is actively sending or receiving data over that port. SpeedOn the SFE2010, a green Speed LED indicates that the port is linked to a 100Mbps device. PoEOn the SFE2010P, a green PoE LED indicates that PoE is active on that port. GigabitThe Gigabit LED lights up to indicate a Gigabit connection on the corresponding port.
Page 6 of the Linksys SFE2010 user manual — Getting to Know the SFE2010/SFE2010P
Page 6 · click to enlarge
Page 6

Getting to Know the SFE2010/SFE2010P

FeatureDescription 1-48The Switch is equipped with 48 auto-sensing, Ethernet (802.3) network ports, which use RJ-45 connectors. The Fast Ethernet ports support network speeds of 10Mbps or 100Mbps. They can operate in half and fullduplex modes. Auto-sensing technology enables each port to automatically detect the speed of the device connected to it, and adjust its speed and duplex accordingly. The switch can deliver a maximum of 15.4W to a PoE port. With regular AC power supply, there is 360W available to all PoE ports, and 280W available with redundant power supply. G1-G2Ports G1-G2 are Ethernet (802.3ab) uplink ports which support network speeds of 10Mbps, 100Mbps, and 1000Mbps. NOTE: A switch is in stacking mode by default. In stacking mode, ports G1 and G2 are reserved for use as stacking ports. miniGBIC1/2The Switch provides two mini-GBIC ports. The mini-GBIC (gigabit interface converter) port is a connection point for a mini-GBIC expansion module, so the Switch can be uplinked via fiber to another switch. Each mini-GBIC port provides a link to a high-speed network segment or individual workstation at speeds of up to 1000Mbps. Use the Linksys MGBT1, MGBSX1, or MGBLH1 mini-GBIC modules with the Switch. The MGBSX1 and the MGBLH1 require fiber cabling with LC connectors, while the MGBT1 requires a Category 5e Ethernet cable with an RJ-45 connector.
Page 7 of the Linksys SFE2010 user manual — SFE2010/P Back Panel
Page 7 · click to enlarge
Page 7

Getting to Know the SFE2010/SFE2010P

SFE2010/P Back Panel

FeatureDescription PowerThe Power port is where you will connect the power cord. ConsoleThe Console port is where you can connect a serial cable to a PC’s serial port for configuration using your PC’s HyperTerminal program. Refer to Chapter 4: Using the Console Interface for Configuration for more information. RPSRedundant Power Supply (Linksys RPS1000)
Page 8 of the Linksys SFE2010 user manual — Maximum Cabling Distances
Page 8 · click to enlarge
Page 8

Connecting Devices 3

Connecting Devices

This chapter explains how to physically connect your network devices to the switch.

  • ”Sample Network Configuration,” on page 5
  • ”Maximum Cabling Distances,” on page 5
  • ”Before You Install the Switch... ,” on page 6
  • ”Placement Options,” on page 6
  • ”Connecting the Cables,” on page 8

Sample Network Configuration

For an example of a possible network configuration, see the application diagrams shown below.

Maximum Cabling Distances

When you connect your network devices, make sure you don’t exceed the maximum cabling distances, which are listed in the following table:

FromToMaximum Distance SwitchSwitch or Hub*100 meters (328 feet) HubHub5 meters (16.4 feet) Switch or HubComputer100 meters (328 feet)

*A hub refers to any type of 100Mbps hub, including regular hubs and stackable hubs. A 10Mbps hub connected to another 10Mbps hub can span up to 100 meters (328 feet).

Sample Network Configuration

Page 9 of the Linksys SFE2010 user manual — Desktop Placement
Page 9 · click to enlarge
Page 9

Connecting Devices

Before You Install the Switch...

Before You Install the Switch...

When you choose a location for the switch, observe the following guidelines:

  • Make sure that the switch will be accessible and that the cables can be easily connected.
  • Keep cabling away from sources of electrical noise, power lines, and fluorescent lighting fixtures.
  • Position the switch away from water and moisture sources.
  • To ensure adequate air flow around the switch, be sure to provide a minimum clearance of two inches (50 mm).
  • Connect the supplied power cord to the switch’s power port, and plug the other end into an electrical outlet.

Placement Options

Before connecting cables to the Ethernet switch, first you will physically install the Ethernet switch. Either set the Ethernet switch on its four rubber feet for desktop placement, mount it in a standard-sized, 19-inch wide for rack-mount placement, or mount it on a wall with the wall- mount brackets provided.

Desktop Placement

1. Attach the rubber feet to the recessed areas on the bottom of the Ethernet switch.
2. Place the Ethernet switch on a desktop near an AC power source.
Page 10 of the Linksys SFE2010 user manual — Rack-Mount Placement
Page 10 · click to enlarge
Page 10

Placement Options Connecting Devices

Rack-Mount Placement

To mount the Ethernet switch in any standard-sized, 19-inch wide, (each Ethernet switch requires 1RU of space in the rack), follow these instructions:

1. Remove the four front screws on one side of the Ethernet switch. Retain the screws for reinstallation.
2. Place one of the supplied spacers on the side of the Ethernet switch so the four holes align to the screw holes.
3. Place a rack mount bracket next to the spacer and reinstall the four screws (removed in step 1).
4. Repeat steps 2 through 3 for the other side of the Ethernet switch.
5. Attach the Ethernet switch to the rack using the supplied screws.
Page 11 of the Linksys SFE2010 user manual — Connecting the Cables
Page 11 · click to enlarge
Page 11

Connecting the Cables Connecting Devices

Wall-Mount Placement

1. On one of the side corners, remove the four front screws on of the Ethernet switch. Retain the screws for re-installation.
2. Place one of the supplied spacers on the side of the Ethernet switch so the four holes align to the screw holes.
3. Place a rack mount bracket next to the spacer and reinstall the four screws (removed in step 1). The wall mount brackets should point towards the bottom of the Ethernet switch.
4. Repeat steps 1 through 3 for the other corners of the Ethernet switch.
5. Attach the Ethernet switch to a wall with appropriate screws (not supplied).

Connecting the Cables

To connect network devices to the Ethernet switch, follow these instructions:

1. For 10/100Mbps devices, connect a Category 5 Ethernet network cable to one of the numbered ports on the Ethernet switch. For a 1000Mbps device, connect a Category 5e Ethernet network cable to one of the uplink ports on the Ethernet switch.
2. Connect the other end to a PC or other network device.
3. Repeat steps 2 and 3 to connect additional devices.
4. If you are using the mini-GBIC port, then insert the mini-GBIC module to the mini-GBIC port. For detailed instructions, refer to the documentation supplied with the mini-GBIC module.
Page 12 of the Linksys SFE2010 user manual — Connecting the Cables Connecting Devices
Page 12 · click to enlarge
Page 12

Connecting the Cables Connecting Devices

5. If you use the console interface to configure the Ethernet switch, then connect the supplied serial cable to the console port (located on the back of the Ethernet switch), and tighten the captive retaining screws. Connect the other end to your PC’s serial port. (The PC must be running VT100 terminal emulation software, such as HyperTerminal.)
6. Connect the supplied power cord to the power port, and plug the other end into an electrical outlet.
7. Power on the network devices connected to the Ethernet switch. Each active port’s corresponding Act/Link LED will light up on the Ethernet switch. If a port has an active Gigabit connection, then its corresponding Gigabit LED will also light up.
8. Proceed as needed:
  • If you will use the console interface to configure the Ethernet switch, proceed to ”Console Configuration” section on page 33 for directions.
  • If you use the Web-based Utility to configure the Ethernet switch, proceed to ”Web Utility Configuration” section on page 50 .
Page 13 of the Linksys SFE2010 user manual — Using Menus in the Web-Based Utility
Page 13 · click to enlarge
Page 13

Web Utility Configuration 4

Connecting to the Switch with the Web-Based Utility

Web Utility Configuration

This chapter provides an introduction to the features of the web-based configuration utility.

Linksys switch provides a complete web-based utility to configure the switch. This utility is accessed through your web browser.

  • ”Connecting to the Switch with the Web-Based Utility ,” on page 10
  • ”Using Menus in the Web-Based Utility,” on page 10
  • ”Viewing On-line Help ,” on page 11

Connecting to the Switch with the Web-Based Utility

You can connect to the switch using a standard web browser on a computer that is connected to the same network as the switch.

To access the web-based utility, enter the IP address of the switch to the address field of your web browser. The default IP address is 192.168.1.254.

Using Menus in the Web-Based Utility

Use the left navigation panel to choose options in the web-based utility.

Linksys SFE2010 — Using Menus in the Web-Based Utility diagram (page 13)
Fig. 2 · Using Menus in the Web-Based Utility
Page 14 of the Linksys SFE2010 user manual — Viewing On-line Help Web Utility Configuration
Page 14 · click to enlarge
Page 14

Viewing On-line Help Web Utility Configuration

Viewing On-line Help

The Web Utility has on-line Help including field definitions for each screen. To access the on- line help for a particular screen, click the Help button on the right side of the screen.

Linksys SFE2010 — Viewing On-line Help Web Utility Configuration diagram (page 14)
Fig. 3 · Viewing On-line Help Web Utility Configuration
Page 15 of the Linksys SFE2010 user manual — Connecting to Your Switch with HyperTerminal
Page 15 · click to enlarge
Page 15

Using the Console 5

Connecting to Your Switch with HyperTerminal

Using the Console

This chapter describes the use of the switch console, which allows you to perform basic configuration of the switch.

The switch features a menu-driven console interface for basic configuration of the switch and management of your network.This chapter describes console interface configuration. Configuration can also be performed through the web utility, which is covered in the next chapter.

  • ”Connecting to Your Switch with HyperTerminal,” on page 12
  • ”Connecting to the Switch with Telnet,” on page 15
  • Logging On to the Console (see page 15)
  • Selecting Menu Options and Actions (see page 15)
  • Using the Switch Main Menu (see page 16)
  • System Configuration (see page 16)
  • Port Status (see page 47)
  • Port Configuration (see page 49)
  • System Mode (Layer 2 / Layer 3) Selection (see page 51)
  • Help (see page 52)
  • Logout (see page 53)

Connecting to Your Switch with HyperTerminal

You can use the HyperTerminal to connect to your switch.

Before you use HyperTerminal to connect to your switch for the first time, you must configure the application on your PC. You can save the settings to use each time you connect to your switch.

Page 16 of the Linksys SFE2010 user manual — Using the Console
Page 16 · click to enlarge
Page 16

Using the Console

Connecting to Your Switch with HyperTerminal

1. Click the Start button. Choose Programs > Accessories > Communications > HyperTerminal .
Linksys SFE2010 — Using the Console diagram (page 16)
Fig. 4 · Using the Console
2. On the Connection Description screen, type a name for this connection, select an icon, and then click OK .
Linksys SFE2010 — Using the Console diagram (page 16)
Fig. 5 · Using the Console
3. On the Connect To screen, use the Connect using drop-down list to select a port to communicate with the switch: COM n , or TCP/ IP.
Page 17 of the Linksys SFE2010 user manual — Using the Console
Page 17 · click to enlarge
Page 17

Using the Console

Connecting to Your Switch with HyperTerminal

4. Set the serial port settings as follows:
Linksys SFE2010 — Using the Console diagram (page 17)
Fig. 6 · Using the Console
  • Bits per second: 115200
  • Data bits: 8
  • Parity: None
  • Stop bits: 1
  • Flow control: None
5. Then, click the OK button.
6. Optionally, on the File menu, click Save to save these settings. The next time that you need to connect to the console, you can open this saved connection.
Page 18 of the Linksys SFE2010 user manual — Selecting Menu Options and Actions
Page 18 · click to enlarge
Page 18

Using the Console

Connecting to the Switch with Telnet

Connecting to the Switch with Telnet

You can connect to the switch with telnet.

1. Open a command line editor and enter telnet . Then, press the Enter key.
2. When the Login screen appears, select Edit and enter admin in the User Name field. Leave the Password field blank.
3. Press the Esc key to return to the Login screen.
4. Select Enter to enter the CLI interface.

Logging On to the Console

1. Start HyperTerminal and open the connection that you configured previously.
2. When the blinking cursor appears, press the Enter key.
3. When prompted to login, enter the default login and password: admin

The Switch Main Menu appears.

Selecting Menu Options and Actions

Within the Console Interface, menus list options in numeric order. Actions appear at the end of the screen. To select menu options and actions, use the following keys on your keyboard:

Arrow keys Move the cursor up, down, left, or right.

Number key Press the menu number and then press Enter key to select a menu option.

Tab Move the cursor from one field to the next on an editing screen.

Enter Select an option that is highlighted by the cursor.

Esc Return to the previous menu or screen, or move cursor from editable fields to Action list.

Key Function

Page 19 of the Linksys SFE2010 user manual — System Configuration
Page 19 · click to enlarge
Page 19

Using the Console

Using the Switch Main Menu

Using the Switch Main Menu

The Switch Main Menu provides access to screens that you can use to configure your system, view or modify port and PoE settings, and view or modify system and stacking mode.

1. System Configuration (see page 16)
2. Port Status (see page 47)
3. Port Configuration (see page 49)
4. System Mode (Layer 2 / Layer 3) Selection (see page 51)
5. Help (see page 52)
0. Logout (see page 53)

System Configuration

The System Configuration Menu provides access to screens where you can manage system information, view or modify management settings, set up user accounts, and manage security settings. It also provides access to screens where you can manage VLAN IDs, IPv4 and IPv6 settings, and download upgrade files. You also will use this menu if you need to restore default settings, reset the switch to the factory default configuration, or reboot the system.

1. System Information (see page 17)
2. Management Settings (see page 19)
Page 20 of the Linksys SFE2010 user manual — System Information
Page 20 · click to enlarge
Page 20
3. Username & Password Settings (see page 24)
4. Security Settings (see page 25)
5. VLAN Management (see page 28)
6. IP Configuration (see page 29)
7. File Management (see page 43)
8. Restore System Default Settings (see page 46)
9. Reset to Factory Settings (see page 46)
10. Reboot System (see page 46)
11. Stack Configuration (see page 47)

0.Back (Select return to the previous menu.)

From the Switch Main Menu, select 1. System Configuration Menu.

System Information

The System Information menu provides access to screens where you can view firmware version information and general system information.

1. Versions (see page 18)
2. General Information (see page 18)

0.Back (Select to return to the previous menu.)

To open this menu:

2. From the System Configuration Menu , select 1. System Information .
3. When you are finished using this screen, select 0. Back .
Page 21 of the Linksys SFE2010 user manual — General Information
Page 21 · click to enlarge
Page 21

Versions

Use the Versions screen to display the boot, software, and hardware firmware versions of the Ethernet switch. In stacking mode, this information is displayed for the stack master.

2. From the System Configuration Menu , select 1. System Information .
3. From the System Information Menu , select 1. Versions .

General Information

Use the General System Information screen to view the system description, system up time, and system MAC address. You also can enter a system contact, system name, and system location.

2. From the System Configuration Menu , select 1. System Information .
3. From the System Information Menu , select 2. General System Information .
Page 22 of the Linksys SFE2010 user manual — Management Settings
Page 22 · click to enlarge
Page 22

To change the system contact, system name, and location:

1. Select Edit , and then make your changes. Press the Tab key to move the cursor from one field to the next.
2. Press the Esc key to return to the Action list.
3. Select Save to save your changes.
4. When the Operation complete message appears, press the Esc key to move the cursor to the Action list.

Management Settings

The Management Settings screen provides access to screens where you can change the settings for serial port, telnet, and secure telnet (SSH).

1. Serial Port Configuration (see page 20)
2. Telnet Configuration (see page 20)
3. SSH Configuration (see page 21)

0.Back (Select to return to the previous menu.)

1. From the Switch Main Menu , select 1. System Configuration Menu .
2. From the System Configuration Menu , select 2. Management Settings .
Page 23 of the Linksys SFE2010 user manual — Telnet Configuration
Page 23 · click to enlarge
Page 23

Serial Port Configuration

Use the Serial Port Configuration screen to view or change the baud rate of the Ethernet switch.

1. From the Switch Main Menu , select 1. System Configuration Menu .
2. From the System Configuration Menu , select 2. Management Settings .
3. From the Management Settings Menu , choose 1. Serial Port Configuration.

To change the baud rate of the serial port:

1. Select Edit , and then make changes.
2. Press the Esc key to move the cursor to the Action list.
3. Select Save to save your changes.
4. When the Operation complete message appears, press the Esc key to move the cursor to the Action list.

Telnet Configuration

Use the Telnet Configuration screen to view or change the time-out settings.

Page 24 of the Linksys SFE2010 user manual — SSH Configuration
Page 24 · click to enlarge
Page 24
1. From the Switch Main Menu , select 1. System Configuration Menu .
2. From the System Configuration Menu , select 2. Management Settings .
3. From the Management Settings Menu , choose 2. Telnet Configuration .

To change the time-out setting:

1. Select Edit , and then make your changes.
2. Press the Esc key to move the cursor to the Action list.
3. Select Save to save your changes.
4. When the Operation complete message appears, press the Esc key to move the cursor to the Action list.

SSH Configuration

The SSH Configuration menu provides access to screens where you can configure SSH server settings, generate crypto keys, and generate keys fingerprints.

1. SSH Server Configuration (see page 22)
2. SSH Status (see page 22)
3. SSH Crypto Key Generation (see page 23)
4. SSH Keys Fingerprints (see page 24)

0.Back (Select to return to the previous menu.)

1. From the Switch Main Menu , select 1. System Configuration Menu .
2. From the System Configuration Menu , select 2. Management Settings .
3. From the Management Settings Menu , choose 3. SSH Configuration .
Page 25 of the Linksys SFE2010 user manual — Management Settings
Page 25 · click to enlarge
Page 25

Use the SSH Server Configuration screen to view or edit the status of the SSH server. You can enable or disable the server and configure the SSH server port

1. From the Switch Main Menu , select 1. System Configuration Menu .
2. From the System Configuration Menu , select 2. Management Settings .
3. From the Management Settings Menu , choose 3. SSH Configuration .
4. From the SSH Configuration Menu , select 1. SSH Server Configuration .

To change SSH Server settings:

1. Select Edit , and then make your changes.
2. Press the Esc key to move the cursor to the Action list.
3. Select Save to save your changes.
4. When the Operation complete message appears, press the Esc key to move the cursor to the Action list.

Use the SSH Status screen to view information about SSH sessions.

SSH Server Configuration · SSH Status

Page 26 of the Linksys SFE2010 user manual — Management Settings
Page 26 · click to enlarge
Page 26
1. From the Switch Main Menu , select 1. System Configuration Menu .
2. From the System Configuration Menu , select 2. Management Settings .
3. From the Management Settings Menu , choose 3. SSH Configuration .
4. From the SSH Configuration Menu , select 2. SSH Status .
5. When you finish using this screen, select Quit .

SSH Crypto Key Generation

Use the SSH Crypto Key Generation screen to generate an SSH RSA or DSA key.

1. From the Switch Main Menu , select 1. System Configuration Menu .
2. From the System Configuration Menu , select 2. Management Settings .
3. From the Management Settings Menu , choose 3. SSH Configuration .
4. From the SSH Configuration Menu , select 3. SSH Crypto Key Generation .
5. When you finish using this screen, select Quit .

To change SSH Crypto Key Generation settings:

1. Select Edit , and then make your changes.
2. Press the Esc key to move the cursor to the Action list.
3. Select Save to save your changes.
4. When the Operation complete message appears, press the Esc key to move the cursor to the Action list.
Page 27 of the Linksys SFE2010 user manual — Username & Password Settings
Page 27 · click to enlarge
Page 27

To generate the crypto key:

1. Verify that the information is correct.
2. Select Execute .
3. When the Operation complete message appears, press the Esc key to move the cursor to the Action list.

Use the SSH Keys Fingerprints screen to view the RSA and DSA fingerprints.

1. From the Switch Main Menu , select 1. System Configuration Menu .
2. From the System Configuration Menu , select 2. Management Settings .
3. From the Management Settings Menu , choose 3. SSH Configuration .
4. From the SSH Configuration Menu , select 4. SSH Keys Fingerprints .
5. When you finish using this screen, select Quit .

Username & Password Settings

You can use the Username & Password Settings screen to view, add, or modify the user accounts for the switch. Up to five users can be assigned.

SSH Keys Fingerprints

Page 28 of the Linksys SFE2010 user manual — Security Settings
Page 28 · click to enlarge
Page 28
2. From the System Configuration Menu , select 3. Username & Password Settings .

To change User & Password settings:

1. Select Edit , and then make your changes. Press the Tab key to move from one field to the next.
2. Press the Esc key to move the cursor to the Action list.
3. Select Save to save your changes.
4. When the Operation complete message appears, press the Esc key to move the cursor to the Action list.

Security Settings

The Security Settings screen provides access to screens where you can generate SSL certificates and view the SSL certificate listings. You also can use this module to disable the active management access profile.

1. SSL Generate Certificate (see page 26)
2. Show Certificate (see page 27)
3. Disable Active Management Access Profile (see page 27)

0.Back (Select to return to the previous menu.)

2. From the System Configuration Menu , select 4. Security Settings .
Page 29 of the Linksys SFE2010 user manual — SSL Generate Certificate
Page 29 · click to enlarge
Page 29

SSL Generate Certificate

Use the SSL Certificate Generation screen to view, edit, and execute device-generated certificates.

2. From the System Configuration menu, select 4. Security Settings .
3. From the Security Settings Menu , select 1. SSL Generate Certificate .

To edit and execute a certificate:

1. Select Edit , and then make your changes. Press the Tab key to move the cursor from field to field.
2. Press the Esc key to move the cursor to the Action list.
3. Select Execute to generate the certificate with the new parameters.
4. When the Operation complete message appears, press the Esc key to move the cursor to the Action list.

The following fields are specified:

Public Key Algorithm Specifies the SSL type

Public Key Length Specifies the SSL RSA key length. (Range: 512 to 2048)

Common Name (FQCN) IP address of the Ethernet switch

Department Name Specifies the department name. (Range: 1 to 32 characters)

Organization Name Specifies the organization name. (Range: 1 to 32 characters)

Locality or City Name Specifies the location or city name. (Range: 1 to 32 characters)

State or Province Name Specifies the state or province name. (Range: 1 to 32 characters)

Page 30 of the Linksys SFE2010 user manual — Disable Active Management Access Profile
Page 30 · click to enlarge
Page 30

Country Name Specifies the country name. (Range: 2 to 2)

Validity Term Specifies number of days certification is valid. (Range: 30 to 3650)

Show Certificate

Use the Show Certificate screen to display the internal certificate.

2. From the System Configuration Menu , select 4. Security Settings .
3. From the Security Settings Menu , select 2. SSL Show Certificate .
4. When you finish using this screen, select Quit .

Disable Active Management Access Profile

You can use select option 3 on the Security Settings menu to disable the active management access profile.

To disable the active management access profile:

2. From the System Configuration menu, select 4. Security Settings .
3. From the Security Settings Menu , select 3. Disable Active Management Access Profile .
4. When the confirmation message appears, press Y to confirm, or press N to cancel.
Page 31 of the Linksys SFE2010 user manual — Default VLAN Setup
Page 31 · click to enlarge
Page 31

VLAN Management

The VLAN Management menu provides access to a screen where you can view or modify the default VLAN ID.

1. Default VLAN Setup (see page 28)

0.Back (Select to return to the previous menu.)

2. From the System Configuration Menu , select 5. Vlan Management .

Default VLAN Setup

You can use the Default VLAN Setup screen to view and change the VLAN ID.

2. From the System Configuration Menu , select 5. Vlan Management .
3. From the VLAN Management menu, press 1. Default VLAN Setup .
Page 32 of the Linksys SFE2010 user manual — IP Configuration
Page 32 · click to enlarge
Page 32

To edit the VLAN ID:

1. Select Edit .
2. Type the VLAN ID.
3. Press the Esc key to move the cursor to the Action list.
4. Select Execute .
5. When the Operation complete message appears, press the Esc key to move the cursor to the Action list.

IP Configuration

The IP Configuration menu provides access to screens where you can manage IPv4 and IPv6 address configuration, HTTP and HTTPS configuration, and network configuration.

1. IPv4 Address Configuration (see page 30)
2. IPv6 Address Configuration (see page 31)
3. HTTP Configuration (see page 37)
4. HTTPS Configuration (see page 37)
5. Network Configuration (see page 38)

0.Back (Select to return to the previous menu.)

2. From the System Configuration Menu , select 6. IP Configuration .
Page 33 of the Linksys SFE2010 user manual — IPv4 Address Configuration
Page 33 · click to enlarge
Page 33

IPv4 Address Configuration

The IPv4 Configuration menu provides access to the IPv4 address settings and DHCP renew.

1. IPv4 Address Settings (see page 30)
2. DHCP Renew (see page 31)

0.Back (Select to return to the previous menu.)

2. From the System Configuration Menu , select 6. IP Configuration .
3. From the IP Configuration menu, select 1. IPv4 Address Configuration .

You can use this screen to view or editing the IPv4 address settings.

2. From the System Configuration Menu , select 6. IP Configuration .
3. From the IP Configuration menu, select 1. IPv4 Address Configuration .

IPv4 Address Settings

Page 34 of the Linksys SFE2010 user manual — IPv6 Address Configuration
Page 34 · click to enlarge
Page 34
4. From the IPv4 Address Configuration menu, select 1. IPv4 Address Settings .

To edit the IPv4 address settings:

1. Select Edit ., and then make the changes. Press the Tab key to move the cursor from one field to the next.
2. Press the Esc key to move the cursor to the Action list.
3. Select Save to save your settings
4. When the Operation complete message appears, press the Esc key to move the cursor to the Action list.

You can select this option to renew DHCP.

To renew DHCP:

2. From the System Configuration Menu , select 6. IP Configuration .
3. From the IP Configuration menu, select 1. IPv4 Address Configuration .
4. From the IPv4 Address Configuration menu, select 2. DHCP Renew . The Operation Complete message appears.

IPv6 Address Configuration

The IPv6 Configuration menu provides access to screens where you can manage the settings for IPv6 and ISATAP.

DHCP Renew

Page 35 of the Linksys SFE2010 user manual — IP Configuration
Page 35 · click to enlarge
Page 35
1. IPv6 Interface Enable (see page 32)
2. IPv6 Address Settings (see page 33)
3. IPv6 Address Table (see page 34)
4. IPv6 ISATAP Enable (see page 34)
5. IPv6 ISATAP Interface Show (see page 35)
6. IPv6 Default Gateway (see page 36)
2. From the System Configuration Menu , select 6. IP Configuration .
3. From the IP Configuration menu, select 2. IPv6 Address Configuration .

You can use the IPv6 Interface Enable screen to enable or disable the IPv6 interface.

1. On the Switch Main Menu , select 6. IP Configuration .
2. On the IP Configuration menu, select 2. IPv6 Address Configuration .
3. On the IPv6 Address Configuration menu, select 1. IPv6 Interface Enable .

To edit the IPv6 interface settings:

1. When you finish using this Select Edit ., and then make the changes. Press the Tab key to move the cursor from one field to the next.
2. Press the Esc key to move the cursor to the Action list.

IPv6 Interface Enable

Page 36 of the Linksys SFE2010 user manual — IP Configuration
Page 36 · click to enlarge
Page 36
3. Select Save to save your settings
4. When the Operation complete message appears, press the Esc key to move the cursor to the Action list.
5. When you are finished working on this screen, select Quit .

You can use the IPv6 Address - Configuration screen to edit the IPv6 address settings.

2. From the System Configuration Menu , select 6. IP Configuration .
3. From the IP Configuration menu, select 2. IPv6 Address Configuration .
4. From the IPv6 Address Configuration menu, select 2. IPv6 Address Settings .

To edit the IPv6 address settings:

1. Select Edit ., and then make the changes. Press the Tab key to move the cursor from one field to the next.
2. Press the Esc key to move the cursor to the Action list.
3. Select Save to save your settings
4. When the Operation complete message appears, press the Esc key to move the cursor to the Action list.

IPv6 Address Settings

Page 37 of the Linksys SFE2010 user manual — IP Configuration
Page 37 · click to enlarge
Page 37

The IPv6 Address Table lists the IPv6 addresses that are configured.

2. From the System Configuration Menu , select 6. IP Configuration .
3. From the IP Configuration menu, select 2. IPv6 Address Configuration .
4. From the IPv6 Address Configuration menu, select 3. IPv6 Address Table .

You can use the IPv6 ISATAP Enable screen to configure the ISATAP tunnel.

2. From the System Configuration Menu , select 6. IP Configuration .
3. From the IP Configuration menu, select 2. IPv6 Address Configuration .
4. From the IPv6 Address Configuration menu, select 4. IPv6 ISATAP Enable .

IPv6 Address Table · IPv6 ISATAP Enable

Page 38 of the Linksys SFE2010 user manual — IP Configuration
Page 38 · click to enlarge
Page 38

To edit the ISATAP tunnel settings

1. Select Edit ., and then make the changes. Press the Tab key to move the cursor from one field to the next.
2. Press the Esc key to move the cursor to the Action list.
3. Select Save to save your settings
4. When the Operation complete message appears, press the Esc key to move the cursor to the Action list.

IPv6 ISATAP Interface Show

You can use the ISATAP Interface Show screen to view the interface type and address.

2. From the System Configuration Menu , select 6. IP Configuration .
3. From the IP Configuration menu, select 2. IPv6 Address Configuration .
4. From the IPv6 Address Configuration menu, select 5. ISATAP Interface Show .
Page 39 of the Linksys SFE2010 user manual — IP Configuration
Page 39 · click to enlarge
Page 39

You can use the IPv6 Default Gateway screen to view or edit information about the IPv6 Default Gateway.

2. From the System Configuration Menu , select 6. IP Configuration .
3. From the IP Configuration menu, select 2. IPv6 Address Configuration .
4. From the IPv6 Address Configuration menu, select 6. IPv6 Default Gateway .

To edit the IPv6 default gateway settings:

1. Select Edit ., and then make the changes. Press the Tab key to move the cursor from one field to the next.
2. Press the Esc key to move the cursor to the Action list.
3. Select Execute to save your settings
4. When the Operation complete message appears, press the Esc key to move the cursor to the Action list.

IPv6 Default Gateway

Page 40 of the Linksys SFE2010 user manual — HTTPS Configuration
Page 40 · click to enlarge
Page 40

HTTP Configuration

You can use the HTTP screen to view and edit the HTTP settings.You can enable or disable the HTTP server and configure the port on which the session is enabled.

To open the screen:

2. From the System Configuration Menu , select 6. IP Configuration .
3. From the IP Configuration menu, select 3. HTTP Configuration .

To change the HTTP settings:

1. Select Edit , and then make your changes.
2. Press the Esc key to move the cursor to the Action list.
3. Select Save to save your changes.
4. When the Operation complete message appears, press the Esc key to move the cursor to the Action list.

HTTPS Configuration

Use the HTTPS Configuration screen to configure HTTPS settings. You can enable or disable the HTTPS server and configure the port on which the session is enabled.

Page 41 of the Linksys SFE2010 user manual — Network Configuration
Page 41 · click to enlarge
Page 41

To open the screen:

2. From the System Configuration Menu , select 6. IP Configuration .
3. From the IP Configuration menu, select 4. HTTPS Configuration .

To change HTTPS settings:

1. Select Edit , and then make your changes.
2. Press the Esc key to move the cursor to the Action list.
3. Select Save to save your changes.
4. When the Operation complete message appears, press the Esc key to move the cursor to the Action list.

Network Configuration

The Network Configuration screen provides access to screens where you can execute ping tests and traceroute tests for IPv4 and IPv6 addresses.

1. Ping IPv4 (see page 39)
2. Ping IPv6 (see page 40)
3. TraceRoute IPv4 (see page 41)
4. TraceRoute IPv6 (see page 42)

0.Back (Select to return to the previous menu.)

To open the screen:

2. From the System Configuration Menu , select 6. IP Configuration .
3. From the IP Configuration menu, select 5. Network Configuration .
Page 42 of the Linksys SFE2010 user manual — IP Configuration
Page 42 · click to enlarge
Page 42

You can use the Ping IPv4 screen to ping an IPv4 address.

To open the screen:

2. From the System Configuration Menu , select 6. IP Configuration .
3. From the IP Configuration menu, select 5. Network Configuration .
4. From the Network Configuration menu, select 1. IPv4 Ping .

To change the IP address:

1. Select Edit , and then enter the IP address.
2. Press the Esc key to move the cursor to the Action list.
3. Select Save to save your changes.
4. When the Operation complete message appears, press the Esc key to move the cursor to the Action list.

To begin the ping test:

1. Select Execute to begin the ping test.
2. After the ping test is complete, the results of the test appear on the screen.
3. When the Operation complete message appears, press the Esc key to move the cursor to the Action list.

Ping IPv4

Page 43 of the Linksys SFE2010 user manual — IP Configuration
Page 43 · click to enlarge
Page 43

You can use the Ping IPv6 screen to ping an IPv6 address.

To open the screen:

2. From the System Configuration Menu , select 6. IP Configuration .
3. From the IP Configuration menu, select 5. Network Configuration .
4. From the Network Configuration menu, select 2. IPv6 Ping .

To change the IP address:

1. Select Edit , and then enter the IPv6 address.
2. Press the Esc key to move the cursor to the Action list.
3. Select Save to save your changes.
4. When the Operation complete message appears, press the Esc key to move the cursor to the Action list.

To begin the ping test:

1. Select Execute to begin the ping test.
2. After the ping test is complete, the results of the test appear on the screen.
3. When the Operation complete message appears, press the Esc key to move the cursor to the Action list.

Ping IPv6

Page 44 of the Linksys SFE2010 user manual — IP Configuration
Page 44 · click to enlarge
Page 44

You can use the TraceRoute IPv4 screen to run a trace route test for an IPv4 address

To open the screen:

2. From the System Configuration Menu , select 6. IP Configuration .
3. From the IP Configuration menu, select 5. Network Configuration .
4. From the Network Configuration menu, select 3. Trace Router IPv4 .

To change the IP address:

1. Select Edit , and then enter the IPv4 address.
2. Press the Esc key to move the cursor to the Action list.

To begin the trace route test:

1. Select Execute to begin the test.
2. After the test is complete, the results of the test appear on the screen.
3. When the Operation complete message appears, press the Esc key to move the cursor to the Action list.

TraceRoute IPv4

Page 45 of the Linksys SFE2010 user manual — IP Configuration
Page 45 · click to enlarge
Page 45

You can use the TraceRoute IPv6 screen to run a trace route test for an IPv6 address.

To open the screen:

2. From the System Configuration Menu , select 6. IP Configuration .
3. From the IP Configuration menu, select 5. Network Configuration .
4. From the Network Configuration menu, select 4. Trace Router IPv6 .

To change the IP address:

1. Select Edit , and then enter the IPv6 address.
2. Press the Esc key to move the cursor to the Action list.

To begin the trace route test:

1. Select Execute to begin the test.
2. After the test is complete, the results of the test appear on the screen.
3. When the Operation complete message appears, press the Esc key to move the cursor to the Action list.

TraceRoute IPv6

Page 46 of the Linksys SFE2010 user manual — Upgrade / Backup IPv4
Page 46 · click to enlarge
Page 46

File Management

The File Management Menu provides access to screens where you can download upgrade files from an IPv4 or IPv6 address.

1. Upgrade / Backup IPv4 (see page 43)
2. Upgrade / Backup IPv6 (see page 44)
3. Active Image (see page 45)

0.Back (Select to return to the previous menu.)

2. From the System Configuration Menu , select 7. File Management .

Upgrade / Backup IPv4

You can use the Upgrade/Backup IPv4 screen to download files from an IPv4 address.

2. From the System Configuration Menu , select 7. File Management .
3. From the File Management Menu , select 1. IPv4 Upgrade/Backup .
Page 47 of the Linksys SFE2010 user manual — Upgrade / Backup IPv6
Page 47 · click to enlarge
Page 47

To enter the IPv4 Upgrade/Backup file name and location:

1. Select Edit , and then make the changes. Press the Tab key to move the cursor from one field to the next.
2. Press the Esc key to move the cursor to the Action list.

To download a file from the specified location:

3. Verify that the file name and location are correct.
4. Select Execute .
5. When the Operation complete message appears, press the Esc key to move the cursor to the Action list.

Upgrade / Backup IPv6

You can use the Upgrade/Backup IPv6 screen to download files from an IPv6 address.

2. From the System Configuration Menu , select 7. File Management .
3. From the File Management Menu , select 2. IPv6 Upgrade/Backup .

To enter the IPv6 Upgrade/Backup file name and location:

1. Select Edit , and then make the changes. Press the Tab key to move the cursor from one field to the next.
2. Press the Esc key to move the cursor to the Action list.
Page 48 of the Linksys SFE2010 user manual — Active Image
Page 48 · click to enlarge
Page 48

To download a file from the specified location:

3. Verify that the file name and location are correct.
4. Select Execute .
5. When the Operation complete message appears, press the Esc key to move the cursor to the Action list.

Active Image

There are two software images on the Ethernet switch: Image 1 and Image 2. When you copy an image to the switch via TFTP, the inactive image is replaced. When you copy an image to the switch via the console port, the active image is replaced.You can use the Active Image screen to specify which image is the active image on the switch.

2. From the System Configuration Menu , select 7. File Management .
3. From the File Management Menu , select 3. Active Image .

To enter the active image settings

1. Select Edit . The cursor moves to the Active Image after Reset field.
2. Press the Space Bar to change the image setting.
3. When the correct image setting appears in the field, press the Esc key to move the cursor to the Action list.
4. Select Execute to save your settings. The selected image will be active after reset.
5. When the Operation complete message appears, press the Esc key to move the cursor to the Action list.
Page 49 of the Linksys SFE2010 user manual — Reboot System
Page 49 · click to enlarge
Page 49

Restore System Default Settings

You can restore the switch to the system default settings.

To restore system default settings

2. From the System Configuration Menu , select 8. Restore System Default Settings .
3. When the confirmation message appears, press y to restore the default settings, or press n to cancel.

Reset to Factory Settings

You can restore the switch to the factory default settings.

To restore factory default settings

2. From the System Configuration Menu , select 9. Restore Factory Settings .
3. When the confirmation message appears, press y to restore the default settings, or press n to cancel.

Reboot System

You can restart the Ethernet switch.

To restore system default settings

2. From the System Configuration Menu , select 10. Reboot System .
3. When the confirmation message appears, press y to restore the default settings, or press n to cancel.
Page 50 of the Linksys SFE2010 user manual — Port Status
Page 50 · click to enlarge
Page 50

Port Status Using the Console

Stack Configuration

You can use the Stack Configuration screen to specify the Stack ID for the Ethernet switch. By default, ID numbers are automatically assigned to each device.

2. From the System Configuration Menu , select 11. Stack Configuration .

Port Status

The Port Status menu provides access to screens where you can view the port status and the PoE status for each port on the switch.

1. Port Status (see page 48)
2. PoE Status (see page 48)

0.Back (Select to return to the previous screen.)

From the Switch Main Menu, press 2. Port Status.

Page 51 of the Linksys SFE2010 user manual — PoE Status
Page 51 · click to enlarge
Page 51

Port Status Using the Console

Port Status

You can use the Port Status screen to view the port connection status. You can use the up or down arrow keys to scroll through all the ports on the switch.

1. From the Switch Main Menu , press 2. Port Status .
2. From the Port Status Men u, press 1. Port Status .

PoE Status

You can use the PoE Status screen to view the PoE status of the ports.

1. From the Switch Main Menu , press 2. Port Status .
2. From the Port Status Men u, press 2. Poe Status .
Page 52 of the Linksys SFE2010 user manual — Port Settings
Page 52 · click to enlarge
Page 52

Port Configuration Using the Console

Port Configuration

The Port Configuration Menu provides access to screens where you can view or modify port settings and PoE settings.

1. Port Settings (see page 49)
2. PoE Settings (see page 50)

0.Back (Select to return to the previous screen.)

From the Switch Main Menu, press 3. Port Configuration.

Port Settings

You can use the Port Settings screen to specify the auto negotiation status, port speed, duplex mode, and flow control settings. You can use the up or down arrow keys to scroll through all the ports on the Ethernet switch.

1. From the Switch Main Menu , press 3. Port Configuration .
2. From the Port Status Men u, press 2. Poe Status .
Page 53 of the Linksys SFE2010 user manual — PoE Settings
Page 53 · click to enlarge
Page 53

Port Configuration Using the Console

To configure the ports:

1. Select Edit .
2. Proceed as needed:

a. Press the down arrow key to scroll down through the list of ports.

b. Press the right arrow key to move the cursor from one field to the next within a row.

c. To change a setting, move the cursor to the field, and then press the Space Bar until the desired setting appears.

Enable Enable or Disable

Auto Neg. On or Off

Spd/Dpx Auto, 10H, 100H, 10F, 100F, 1000F

Flow Ctrl Auto, On or Off

3. Press the Esc key to move the cursor to the Action list.
4. Select Save to save your settings
5. When the Operation complete message appears, press the Esc key to move the cursor to the Action list.

PoE Settings

You can use the PoE Settings screen to specify the priority and PoE settings for each port. You can use the up or down arrow keys to scroll through all the ports on the Ethernet switch.

1. From the Switch Main Menu , press 3. Port Configuration .
2. From the Port Status Men u, press 2. Poe Settings .

Field Settings

Page 54 of the Linksys SFE2010 user manual — System Mode (Layer 2 / Layer 3) Selection
Page 54 · click to enlarge
Page 54

Using the Console

System Mode (Layer 2 / Layer 3) Selection

To configure the PoE settings:

1. Select Edit .
2. Proceed as needed:

a. Press the down arrow key to scroll down through the list of ports.

b. Press the right arrow key to move the cursor from one field to the next within a row.

c. To change a setting, move the cursor to the field, and then press the Space Bar until the desired setting appears.

Priority Low, High, or Critical

Enable Enable or Disable

3. Press the Esc key to move the cursor to the Action list.
4. Select Save to save your settings
5. When the Operation complete message appears, press the Esc key to move the cursor to the Action list.

System Mode (Layer 2 / Layer 3) Selection

You can use the System Mode Selection screen to specify whether the Ethernet switch is operating in Layer 2 or Layer 3 mode. You can also configure stacking mode from this screen.

From the Switch Main Menu, press 4. System Mode.

Field Settings

Page 55 of the Linksys SFE2010 user manual — Help
Page 55 · click to enlarge
Page 55

Help Using the Console

To edit the system mode or stacking mode:

1. Select Edit .
2. Proceed as needed:

a. Press the down arrow key to scroll down through the list of ports.

b. Press the Tab key to move the cursor from one field to the next.

c. To change a setting, move the cursor to the field, and then press the Space Bar until the desired setting appears.

System Mode after Reset

Layer 2 or Layer 3

Stacking Mode after Reset

3. Press the Esc key to move the cursor to the Action list.
4. Select Save to save your settings
5. When the Operation complete message appears, press the Esc key to move the cursor to the Action list.
6. Reboot the Ethernet switch. Your new settings will take effect after reboot.

Help

You can use the Help screen to view information about the console menus and options.

From the Switch Main Menu, press 5. Help.

Field Settings · Stack or Standalone

Page 56 of the Linksys SFE2010 user manual — Logout Using the Console
Page 56 · click to enlarge
Page 56

Logout Using the Console

Logout

The Logout command lets you logout from the Ethernet switch.

Page 57 of the Linksys SFE2010 user manual — EU Contacts
Page 57 · click to enlarge
Page 57

US/Canada Contacts A

Contacts

For additional information or troubleshooting help, refer to the User Guide on the CD-ROM. Additional support is also available by phone or online.

US/Canada Contacts

  • 24-Hour Technical Support: 800-326-7114
  • RMA (Return Merchandise Authorization): <a href="http://www.linksys.com/warranty" rel="nofollow noopener" target="_blank">http://www.linksys.com/warranty</a>
  • Website: <a href="http://www.linksys.com" rel="nofollow noopener" target="_blank">http://www.linksys.com</a>
  • FTP Site: ftp://ftp.<a href="http://linksys.com" rel="nofollow noopener" target="_blank">linksys.com</a>
  • Support: <a href="http://www.linksys.com/support" rel="nofollow noopener" target="_blank">http://www.linksys.com/support</a>
  • Sales Information: 800-546-5797 (800-LINKSYS)

EU Contacts

  • Website: <a href="http://www.linksys.com/international" rel="nofollow noopener" target="_blank">http://www.linksys.com/international</a>
  • Product Registration: <a href="http://www.linksys.com/registration" rel="nofollow noopener" target="_blank">http://www.linksys.com/registration</a>
Page 58 of the Linksys SFE2010 user manual — B
Page 58 · click to enlarge
Page 58

B

Customer Site Survey

Use this Customer Site Survey to gather customer contact information and other information about the customer site that will be needed for the implementation and installation of the Linksys Solution.

Shipping Address (if different from above)

After Hours Contact Phone Number

Is this Site owned and maintained by the customer? Yes No

If this site is not customer-owned, who is the owner and maintainer of the site?

Is this a manned site? Yes No

Specify the hours of operation (for example, Monday through Friday, 8am to 5pm, Saturday 9 am to 12 Noon).

Show 18 more labels / short text on this page
Site Business Address · Business Name · Street Address · City · State · Zip Code · Street Address · City · State · Zip Code · Site Contact · Contact Name · Title · Phone · Mobile · Fax · Pager # · E-mail
Page 59 of the Linksys SFE2010 user manual — Customer Site Survey
Page 59 · click to enlarge
Page 59

How many users are at your site?

Phone number and location of the telephone nearest to the Linksys equipment

Specify room access procedures (for example, must visiting personnel be escorted by customer personnel?).

Specify any special security/safety procedures, such as the need for safety glasses, safety shoes, and the location(s) of hardhat areas.

Specify the name and phone number of the site coordinator responsible for ensuring that the site is adequately prepared for the installation of the Cisco equipment.

Name:

Phone:

What is the downlink and uplink speed of your broadband connection?

Uplink speed (must be greater than 768 Kbps):

Downlink speed (must be greater than 768 Kbps):

Does your network use a firewall? Yes No

Show 4 more labels / short text on this page
Access Procedures · Security/Safety Procedures · Site Coordinator · Network/Bandwidth
Page 60 of the Linksys SFE2010 user manual — Exclusions and Limitations
Page 60 · click to enlarge
Page 60

Limited Warranty C

Warranty Information

Limited Warranty

Linksys warrants this Linksys hardware product against defects in materials and workmanship under normal use for the Warranty Period, which begins on the date of purchase by the original end-user purchaser and lasts for the period specified for this product at www.linksys.com/ warranty. The internet URL address and the web pages referred to herein may be updated by Linksys from time to time; the version in effect at the date of purchase shall apply.

This limited warranty is non-transferable and extends only to the original end-user purchaser. Your exclusive remedy and Linksysf entire liability under this limited warranty will be for Linksys, at its option, to (a) repair the product with new or refurbished parts, (b) replace the product with a reasonably available equivalent new or refurbished Linksys product, or (c) refund the purchase price of the product less any rebates. Any repaired or replacement products will be warranted for the remainder of the original Warranty Period or thirty (30) days, whichever is longer. All products and parts that are replaced become the property of Linksys.

Exclusions and Limitations

This limited warranty does not apply if: (a) the product assembly seal has been removed or damaged, (b) the product has been altered or modified, except by Linksys, (c) the product damage was caused by use with non.Linksys products, (d) the product has not been installed, operated, repaired, or maintained in accordance with instructions supplied by Linksys, (e) the product has been subjected to abnormal physical or electrical stress, misuse, negligence, or accident, (f ) the serial number on the Product has been altered, defaced, or removed, or (g) the product is supplied or licensed for beta, evaluation, testing or demonstration purposes for which Linksys does not charge a purchase price or license fee.

ALL SOFTWARE PROVIDED BY LINKSYS WITH THE PRODUCT, WHETHER FACTORY LOADED ON THE PRODUCT OR CONTAINED ON MEDIA ACCOMPANYING THE PRODUCT, IS PROVIDED gAS ISh WITHOUT WARRANTY OF ANY KIND. Without limiting the foregoing, Linksys does not warrant that the operation of the product or software will be uninterrupted or error free. Also, due to the continual development of new techniques for intruding upon and attacking networks, Linksys does not warrant that the product, software or any equipment, system or network on which the product or software is used will be free of vulnerability to intrusion or attack. The product may include or be bundled with third party software or service offerings. This limited warranty shall not apply to such third party software or service offerings. This limited warranty does not guarantee any continued availability of a third party’s service for which this product’s use or operation may require.

TO THE EXTENT NOT PROHIBITED BY LAW, ALL IMPLIED WARRANTIES AND CONDITIONS OF MERCHANTABILITY, SATISFACTORY QUALITY OR FITNESS FOR A PARTICULAR PURPOSE ARE LIMITED TO THE DURATION OF THE WARRANTY PERIOD. ALL OTHER EXPRESS OR IMPLIED CONDITIONS, REPRESENTATIONS AND WARRANTIES, INCLUDING, BUT NOT LIMITED TO, ANY IMPLIED WARRANTY OF NON-INFRINGEMENT, ARE DISCLAIMED. Some jurisdictions do not allow limitations on how long an implied warranty lasts, so the above limitation may not apply to you. This limited warranty gives you specific legal rights, and you may also have other rights which vary by jurisdiction.

Page 61 of the Linksys SFE2010 user manual — Technical Support
Page 61 · click to enlarge
Page 61

TO THE EXTENT NOT PROHIBITED BY LAW, IN NO EVENT WILL LINKSYS BE LIABLE FOR ANY LOST DATA, REVENUE OR PROFIT, OR FOR SPECIAL, INDIRECT, CONSEQUENTIAL, INCIDENTAL OR PUNITIVE DAMAGES, REGARDLESS OF THE THEORY OF LIABILITY (INCLUDING NEGLIGENCE), ARISING OUT OF OR RELATED TO THE USE OF OR INABILITY TO USE THE PRODUCT (INCLUDING ANY SOFTWARE), EVEN IF LINKSYS HAS BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES. IN NO EVENT WILL LINKSYS’ LIABILITY EXCEED THE AMOUNT PAID BY YOU FOR THE PRODUCT. The foregoing limitations will apply even if any warranty or remedy provided under this limited warranty fails of its essential purpose. Some jurisdictions do not allow the exclusion or limitation of incidental or consequential damages, so the above limitation or exclusion may not apply to you.

Obtaining Warranty Service

If you have a question about your product or experience a problem with it, please go to www.linksys.com/support where you will find a variety of online support tools and information to assist you with your product. If the product proves defective during the Warranty Period, contact the Value Added Reseller (VAR) from whom you purchased the product or Linksys Technical Support for instructions on how to obtain warranty service. The telephone number for Linksys Technical Support in your area can be found in the product User Guide and at www.linksys.com Have your product serial number and proof of purchase on hand when calling. A DATED PROOF OF ORIGINAL PURCHASE IS REQUIRED TO PROCESS WARRANTY CLAIMS. If you are requested to return your product, you will be given a Return Materials Authorization (RMA) number. You are responsible for properly packaging and shipping your product to Linksys at your cost and risk. You must include the RMA number and a copy of your dated proof of original purchase when returning your product. Products received without a RMA number and dated proof of original purchase will be rejected. Do not include any other items with the product you are returning to Linksys. Defective product covered by this limited warranty will be repaired or replaced and returned to you without charge. Customers outside of the United States of America and Canada are responsible for all shipping and handling charges, custom duties, VAT and other associated taxes and charges. Repairs or replacements not covered under this limited warranty will be subject to charge at Linksys’ then-current rates.

Technical Support

This limited warranty is neither a service nor a support contract. Information about Linksys’ current technical support offerings and policies (including any fees for support services) can be found at: www.linksys.com/support This limited warranty is governed by the laws of the jurisdiction in which the Product was purchased by you. Please direct all inquiries to: Linksys, P.O. Box 18558, Irvine, CA 92623

Obtaining Warranty Service

Page 62 of the Linksys SFE2010 user manual — EC Declaration of Conformity (Europe)
Page 62 · click to enlarge
Page 62

D

Federal Communication Commission Interference Statement

This Equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications.

Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense.

Industry Canada Statement

The Class [A] digital apparatus meets all requirements of the Canadian Interference-Causing Equipment Regulation. Cet appareil numerique de la class [A] respecte toutes les exigences du Reglement sur le materiel brouilleur du Canada.

EC Declaration of Conformity (Europe)

In compliance with the EMC Directive 89/336/EEC, Low Voltage Directive 73/23/EEC, and Amendment Directive 93/68/EEC, this product meets the requirements of the following standards:

  • EN55022 Emission
  • EN55024 Immunity
Page 63 of the Linksys SFE2010 user manual — E
Page 63 · click to enlarge
Page 63
Linksys SFE2010 — Specifications diagram (page 63)
Fig. 7 · Specifications

E

Specifications

  • Model
  • SFE2010 48-port 10/100 Ethernet Switch
  • SFE2010P 48-port 10/ 100 Ethernet Switch with PoE
  • IEEE 802.3af PoE on delivered over any of the 48 10/100 ports
  • Power budget allows for max power of 15.4W to a FE port, with 360W available to all FE ports on regular AC, and 280W available on redundant power supply

Ports 48 RJ-45 connectors for 10BASE-T/100BASE-TX + 2 10BASE-T/100BASE-TX/ 1000Base-T + 2 mini-GBIC ports Console port Auto MDI/MDI-X Autonegotiate/Manual setting RPS port for connecting to Redundant Power Supply unit

Cabling Type UTP CAT 5 or better for 10BASE-T/100BASE-TX, UTP CAT 5e or better for 1000BASE- T

Switching Capacity 17.6 Gig non-blocking

Forwarding Capacity 13M packets per second (64-byte packet)

LEDs Power, Fan, Link/Act, PoE, Speed, RPS, Master, Stack ID 1 - 8

  • Stack Operation
  • Up to 192 ports in a stack
  • Hot Insertion and removal
  • Ring and Chain stacking options
  • Master and Backup master for resilient stack control
  • Auto-numbering or manual configuration of units in stack

Layer 2 options 8K 256 active VLANs (4096 range) Port-based and 802.1Q Tag-based VLANs Protocol-based VLAN Management VLAN Multicast TV VLAN Private VLAN Edge (PVE) GVRP Head of line blocking prevention

Layer 3 options Static Routing CIDR (Classless Interdomain Routing) 60 Static Routes IPv4 and IPv6 Forwarding in silicon - Wirespeed forwarding of layer 3 traffic

Buttons Reset Button

Page 64 of the Linksys SFE2010 user manual — Specifications
Page 64 · click to enlarge
Page 64

Environment Operating Temp: Operating Temp. 0ºC to 40ºC (32ºF to 104ºF) Storage Temp: Storage Temp. -20ºC to 70ºC Operating Humidity: Operating Humidity 10% to 90% relative humidity, Non- Condensing Storage Humidity: Storage Humidity 10% to 95% relative humidity, Non- Condensing

Web User Interface Built-in Web UI for easy browser-based configuration (HTTP/HTTPS)

SNMP SNMP version 1, 2c, 3 with support for traps

SNMP MIBs SNMP version 1, 2c, 3 with support for traps RFC1213 MIB-2, RFC2863 Interface MIB, RFC2665 Ether-like MIB, RFC1493 Bridge MIB, RFC2674 Extended Bridge MIB (P-bridge, Q-bridge), RFC2819 RMON MIB (groups 1,2,3,9 only), RFC2737 Entity MIB, RFC 2618 RADIUS Client MIB RFC 1215 Traps

RMON Embedded Remote Monitoring (RMON) software agent supports four RMON groups (history, statistics, alarms, and events) for enhanced traffic management, monitoring, and analysis.

Firmware Upgrade Web Browser upgrade (HTTP) and TFTP Dual images for resilient firmware upgrades

Port Mirroring Traffic on a port can be mirrored to another port for analysis with a network analyzer or RMON probe

Other Management Traceroute Single IP Management Secure Socket Layer (SSL) security for Web UI Secure Shell (SSH) RADIUS Port Mirroring TFTP upgrade DHCP Client BootP SNTP Xmodem upgrade Cable Diagnostics PING Syslog Telnet Client (SSH secure support)

IEEE 802.1x 802.1x - RADIUS Authentication. MD5 Hash Guest VLAN Single/Multiple Host mode

Page 65 of the Linksys SFE2010 user manual — Specifications
Page 65 · click to enlarge
Page 65

Access Control ACLs - Drop or Rate Limit based on: Source and Destination MAC-based Source and Destination IP address Protocol Port VLAN DSCP/IP Precedence TCP/UDP Source and Destination ports 802.1p priority Ethernet Type ICMP packets IGMP packets DHCP Snooping ARP Inspection IP Source Address Guard Up to 1018 rules

Link Aggregation Link Aggregation using IEEE 802.3ad LACP Up to 8 ports in up to 8 groups

Storm Control Broadcast, Multicast and Unknown Unicast

DOS prevention DOS Attack prevention

Spanning Tree IEEE 802.1D Spanning Tree, IEEE 802.1w Rapid Spanning Tree, IEEE 802.1s Multiple Spanning Tree, Fast Linkover

IGMP Snooping IGMP (v1/v2) snooping limits bandwidth-intensive video traffic to only the requestors. Support 256 multicast groups.

Power Redundancy Connection to RPSU for power redundancy

  • QoS Priority levels: 4 Hardware queues Scheduling: Priority Queuing and Weighted Round Robin (WRR) Class of Service:
  • Port-based
  • 802.1p VLAN priority based
  • IPv4/v6 IP Precedence/TOS/DSCP based
  • Diffserv
  • Classification and Remarking ACLs Rate Limiting:
  • Ingress policer
  • Egress rate control
  • Per VLAN Statistics: 16 meters

Standards 802.3 10BASE-T Ethernet, 802.3u 100BASE-TX Fast Ethernet, 802.3ab 1000BASE-T Gigabit Ethernet, 802.3z Gigabit Ethernet, 802.3x Flow Control, 802.3 ad LACP, 802.1d STP, 802.1Q/p VLAN, 802.1w Rapid STP, 802.1s Multiple STP, 802.1x Port Access Authentication

Certifications UL (UL 60950), CSA (CSA 22.2), CE mark, FCC Part 15 (CFR 47) Class A

Regulatory Compliance Products with the CE Marking indicate compliance with the 89/336/EEC and 73/ 23/EEC directives, which include the safety and EMC standards listed below.

Page 66 of the Linksys SFE2010 user manual — Specifications
Page 66 · click to enlarge
Page 66

Safety UL 60950-1 IEC60950-1 CB / TUV/Rh CSA-C22.2 No. 60950 EN 60950 AS/NZS 60950-1 C-Tick

EMC FCC Part 15 (CFR 47) Class A ICES-003 Class A EN 55022 Class A CISPR22 Class A EN 55024, EN 50082-1, EN 61000-3-2, EN 61000-3-3, EN 61000-6-1

Dimensions Metric: 440 mm (W) x 375 mm (H) x 44 mm (D) English: 17.32 in. (W) x 14.70 in. (H) x 1.73 in. (D)

Unit Weight SFE2010 —4.94kg, or10.89 lbs. (174.25 oz.) SFE2010P — 4.94kg, or10.89 lbs. (174.25 oz.)

Power SFE2010 — 100-240V 47-63Hz, Internal, Universal; Also equipped with external redundant power supply connector for external power supply, -48VDC SFE2010P — 100-240V 47-63Hz, Internal, Universal; Also equipped with external redundant power supply connector for external power supply, -48VDC

Page 67 of the Linksys SFE2010 user manual — 080312A-LB
Page 67 · click to enlarge
Page 67
Linksys SFE2010 — Specifications diagram (page 67)
Fig. 8 · Specifications

080312A-LB

Linksys SFE2010 — 080312A-LB diagram (page 67)
Fig. 9
Sources

References & links

Pages referenced in this manual — manufacturer, support and downloads.

Ask about the Linksys SFE2010

Owners and our team usually reply within a day — and your question helps the next person too.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
No questions yet about the Linksys SFE2010

Be the first to ask — other owners or our team will answer.

Original document

Linksys SFE2010 manual PDF

67 pages·1.6 MB·Switch·PDF
Click any page above to open it here
Page 1 / …
100%
Loading pages…