Never obstruct or block the ventilation slots or other openings with
objects, and do not position the device in any location where there is
© LINDY ELECTRONICS LIMITED & LINDY-ELEKTRONIK GMBH - FIRST EDITION (AUG 2002)
insufficient ventilation.


© LINDY ELECTRONICS LIMITED & LINDY-ELEKTRONIK GMBH - FIRST EDITION (AUG 2002)
www.LINDY.com
Safety Precautions


The KVM Terminal LCD uses a standard DDC compatible 15-pin VGA connector.
display. If you choose a video mode which is not listed then this may result in an
640*350@85Hz 37.861 85.080 31.500 640*400@85Hz 37.861 85.080 31.500 720*400@85Hz 37.927 85.039 35.500 640*480@60Hz 31.469 59.940 25.175 640*480@72Hz 37.861 72.809 31.500 640*480@75Hz 37.500 75.000 31.500
640*480@85Hz 43.269 85.008 36.000 800*600@56Hz 35.156 56.250 36.000 800*600@60Hz 37.879 60.017 40.000 800*600@72Hz 48.077 72.188 50.000 800*600@75Hz 46.875 75.000 49.500
800*600@85Hz 53.674 85.061 56.250 1024*768@60Hz 48.363 60.004 65.000 1024*768@72Hz 56.476 70.069 75.000 1024*768@75Hz 60.023 75.029 78.750
1024*768@85Hz 68.677 84.997 94.500
The following table lists the display modes best suited for use with the LCD
IBM MODES
VESA MODES
2-1 Video Input Pin Assignment
0.5KHz
Applicable video timing:
unsatisfactory picture.
VGA
XGA



latches on either side of the rails. The
drawer can now be pushed back into
gently slide the drawer
viewing position. Now
back to a comfortable
a closed position.
position.

The OSD main menu is displayed on screen when 3 key is pressed. The OSD menu is

Auto Comfit Auto comfit the clock phase and position
H Position Adjust the horizontal image position
V Position Adjust the vertical image position
INPUT SELECT Select the input signal source
INFORMATION Check the Input information
CLR CLEAR EEPROM Set to the factory default
RECALL Recall EEPROM default
Clock Adjust the pixel clock
Phase Adjust the pixel phase
EXPAND Expand the image
sub-menu.
3 button to enter sub-menu. 3. Change the settings After the sub-menu appears, use the Adjust (+) and Adjust (-) buttons to change the
5 Adjust (-): To scroll down in menu or to decrease value of selected item.
4 Adjust (+): To scroll up in menu or to increase value of selected item.
3 Menu: Enter the OSD adjust menu and select the menu.

SWITCH NO. FUNCTION
4 ADJUST (+)
2 Auto: Auto adjusts the image.
select exit icon to exit the main menu.
Display Controls
1 RESET
3 MENU
then push 3 to save.
setting values.




per line (sample per line). A slider with current value is displayed.
colour and position. Select "Auto tracking" to adjust phase and
The item "Clock” is used to adjust the number of clocks (pixels)
The item "Phase” is used to adjust the ADC sample pixel clock.
The main menu item "Auto config” is used to perform automatic
configuration of the phase, clock, colour, vertical and horizontal
position. Select sub-menu "Auto adjust” to adjust phase, clock,
A slider with current value is displayed. The range of phase
clock. Select "Auto position" to adjust horizontal and vertical
adjustment value is 0 to 31 for 0 to 360 degrees.
position. Select "Auto gain" to adjust colour.
2-9 Phase
2-8 Clock
The item "H-Position" is used to adjust the horizontal image position.
A slider with current value is displayed. The range of the horizontal
BRIGHTNESS Sets the brightness of the display
CONTRAST Sets the contrast of the display
The item "V-Position" is used to adjust the vertical image position.
OSD OSD ADJUST Set up OSD position and size
FLT EDGE FLITER Adjust the image sharpness
A slider with current value is displayed. The range of vertical
MISC FUNC Adjust the image colour
EXIT EXIT Exit the menu and save
V - P O S I T I O N
LINE WRITE Test display
SCALE UP Don't care
position adjustment value is 0 to 250.
position adjustment value is 0 to 31.
2-7 Vertical Position
0 125 250 · 0 125 250

The item "Recall" is used to set the LCD to the default values. "Yes" sets
This item is used to display colour bar, dot, cross line and H pattern.
The item "Clear EEPROM" is used to set the EEPROM to factory
the horizontal, vertical, phase, clock to default values.
MOTION MODE
YES NO
RECALL
Still Mode
COLOR BAR
H PATTERN
RETURN
2-15 Clear EEPROM
2-16 Line Write
2-14 Recall
default.
sub-menu, zoom "In/Out" to adjust the display size from -15 to 15.
The main menu "Expand" is used to adjust display size, select the
INPUT SELECT
INFORMATION
1024 x 768 60HZ
FULL SCREEN
NTSC VISEO IN
HS1PRD : 2035
HS1PLS : 204
SCAN : NINT
VS1POL : NEG
VS1POL : NEG
EXPAND
PAL VIDEO IN
VS1PRD : 806
RETURN
VS1PLS : 6
VTOTAL: 0
RETURN
This item displays VGA Input information.
Please select to sub-menu "VGA"
2-13 Information
2-11 Expand

The item "OSD Blending” is used adjust the appearance of the OSD
horizontal position. The range of the adjustment value is 0 to 255.
vertical position. The range of the adjustment value is 0 to 255.
The item "OSD Font Size" is used adjust the size of the OSD
The item "OSD H Position” is used to adjust the OSD menu
The item "OSD V Position” is used to adjust the OSD menu
The main menu item "Contrast" is used to adjust the contrast
of the panel. A slider with current contrast value is displayed.
C O N T R A S T
OSD OSD ADJUST
The range of contrast adjustment value is 0 to 255.
OSD BLENDING
OSD FONT SIZE
menu. There are four steps for selection.
menu. There are four steps for selection.
2-19 OSD Adjust
2-20 Contrast
blue channel in ADC. The range of the adjustment value is 0 to 63.
The item "ADC R GAIN” is used to adjust the gain of red channel
The item "ADC B GAIN” is used to adjust the gain of blue channel
The item "ADC G OFFSET” is used to adjust the off set of green
The main item "Edge Filter" is used to adjust the sharpness of the
channel in ADC. The range of he adjustment value is 0 to 255.
channel in ADC. The range of the adjustment value is 0 to 63.
channel in ADC. The range of the adjustment value is 0 to 63.
The item " ADC R OFFSET” is used to adjust the offset of red
The item "ADC B OFFSET” is used to adjust the off set of
The item "ADC G GAIN” is used to adjust the gain of green
in ADC. The range of the adjustment value is 0 to 255.
in ADC. The range of the adjustment value is 0 to 255.
ADC R GAIN (Analog / Digital Converter Gain Settings)
display. The range of the adjustment is -63 to 63.
MISC FUNC
ADC R OFFSET
ADC G OFFSET
ADC B PFFSET
ADC R GAIN
ADC G GAIN
ADC B GAIN
RETURN
2-18 MISC FUNC
2-17 Edge Filter
ADC G OFFSET
ADC B OFFSET
ADC R OFFSET
ADC G GAIN
ADC B GAIN

This equipment has been tested and found to comply
This equipment does not exceed the class B limits for
radio noise emissions from digital apparatus set out in
brouillage radioélectriques publié par le ministère
Operation is subject to the following two conditions:
This device must accept any interference received.
Shielded cables must be used with this equipment to maintain compliance with radio frequency
Including interference that may cause undesired
Canadian Department of Communications RFI
the radio interference regulations of the Canadian
Le présent appareil numérique n’émet pas de
energy emission regulations and ensure a suitably high level of immunity to electromagnetic
FCC Compliance Statement (United States)
bruits radioélectriques dépassant les limites
applicables aux appareils numériques de la
classe A prescrites dans le règlement sur le
(1) This device may not cause harmful

des Communications du Canada
Department of Communications.
© LINDY ELECTRONICS LIMITED & LINDY-ELEKTRONIK GMBH - FIRST EDITION (AUG 2002)
with part 15 of FCC rules.
interference.
operation.
device) in accordance with the specifications in the
guarantee that harmful interference will not occur in
which can be determined by turning the equipment
that to which the receiver is connected. (d) Consult
This equipment complies with the requirement for
designed to provide reasonable protection against
uses and can radiate radio frequency energy and if
radio or television reception. However, there is no
cause interference to radio or television reception,
antenna. (b) Increase the separation between the
European Standard EN55022. These limits are
harmful interference. This equipment generates,
on and off, the user is encouraged to correct the
equipment to an outlet on a circuit different from
CE mentioned in the European Directive and
This equipment has been tested and found to
comply with the limits (for a class B computing
not installed and used in accordance with the
instructions may cause harmful interference to
a particular installation. If this equipment does
interference with one or more of the following
equipment and the receiver. (c) Connect the
the supplier or an experienced radio / TV
European EMC directive 89/336/EEC
Standards EN55022 and EN55024.
technician for help.
disturbances.
The main menu item "Brightness" is used to adjust the brightness
of the panel. A slider with current brightness value is displayed.
The range of brightness adjustment value is 0 to 255.
YES NO
EXIT EXIT
Exit the menu and save.
2-22 EXIT
statement · CE statement · 0 126 255