LN- 15 WIRE FEEDER SVM166-A April, 2006 Safety Depends on Y ou Lincoln arc welding and cutting equipment is designed and built with safety in mind. However , your overall safety can be increased by pr oper installation . . . and thoughtful operation on your part.
Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC i SAFETY i LN-15 FOR ENGINE powered equipment. 1.a. T urn the engine off before troubleshooting and maintenance work unless the maintenance work requires it to be running.
Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC ii SAFETY ii LN-15 ARC RA YS can burn. 4.a. Use a shield with the proper filter and cover plates to protect your eyes from sparks and the rays of the arc when welding or observing open arc welding.
LN-15 SAFETY iii iii Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC FOR ELECTRICALL Y powered equipment. 8.a. T urn off input power using the disconnect switch at the fuse box before working on the equipment. 8.b. Install equipment in accordance with the U.
LN-15 SAFETY iv iv Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC PRÉCAUTIONS DE SÛRETÉ Pour votre propre protection lire et observer toutes les instructions et.
LN-15 v v MASTER T ABLE OF CONTENTS FOR ALL SECTIONS Safety . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . i-iv Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC LN-15 Section A-1 Section A-1 T ABLE OF CONTENTS - INST ALLA TION SECTION - Installation ..............................................................................
LN-15 Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC A-2 INST ALLA TION A-2.
A-3 A-3 LN-15 Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC INST ALLA TION SAFETY PRECAUTIONS ELECTRIC SHOCK CAN KILL. • ONL Y QUALIFIED PERSONNEL SHOULD PERFORM THIS INST ALLA TION.
INST ALLA TION LN-15 A-4 A-4 Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC WELD CABLE CONNECTIONS ELECTRIC SHOCK CAN KILL. • Only a qualified electrician should connect the electrode leads to the LN-15.
LN-15 INST ALLA TION A-5 A-5 Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC.
LN-15 INST ALLA TION A-6 A-6 Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC GUN AND CABLE ASSEMBLIES A variety of Lincoln 10' (3.
LN-15 INST ALLA TION A-7 A-7 Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC FEEDING WIRE ELECTRODE • ELECTRIC SHOCK CAN KILL.
LN-15 NOTES A-8 A-8 Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC.
Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC LN-15 Section B-1 Section B-1 T ABLE OF CONTENTS - OPERA TION SECTION - Operation .....................................................................................
Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC B-2 B-2 LN-15 OPERA TION • ELECTRIC SHOCK CAN KILL.
LN-15 OPERA TION B-3 B-3 Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC GENERAL DESCRIPTION The LN-15 is a light weight, portable, durable semi- automatic wire feeder .
OPERA TION LN-15 B-4 B-4 Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC 1 2 3 4 5 6 7 3. WIRE FEED SPEED KNOB - The Wire Feed Speed knob is a 3-3/4 turn potentiometer that adjusts of the rate of feeding electrode.
Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC OPERA TION B-5 B-5 LN-15 LN-15 POWER-UP SEQUENCE NORMAL POWER-UP DISPLA Y When power is first applied to the LN-15, the display will momentarily show set-up information.
LN-15 OPERA TION B-6 B-6 Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC SPRING TENSION ARM The pressure arm controls the amount of force the drive rolls exert on the wire.
LN-15 OPERA TION B-7 B-7 Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC 6. Remove the outer wire guide, and push the gun bushing out of the wire drive.
LN-15 OPERA TION B-8 B-8 Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC SCFH Liter/Min. 10 4.7 20 9.4 30 14.2 40 18.9 50 23.6 60 28.
LN-15 OPERA TION B-9 B-9 Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC CONST ANT CURRENT OPERA TION ( See Figure B.
LN-15 OPERA TION B-10 B-10 Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC S.
LN-15 OPERA TION B-11 B-11 Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC M.
LN-15 NOTES B-12 B-12 Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC.
Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC LN-15 Section C-1 Section C-1 T ABLE OF CONTENTS - ACCESSORIES SECTION - Accessories ..................................................................................
LN-15 ACCESSORIES C-2 C-2 Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC F ACTOR Y INST ALLED EQUIPMENT • K1500-2 Gun Receiver Bushing.
Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC LN-15 Section D-1 Section D-1 T ABLE OF CONTENTS - MAINTENANCE SECTION - Maintenance ..................................................................................
D-2 D-2 LN-15 Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC MAINTENANCE ELECTRIC SHOCK can kill. • Do not operate with covers removed.
1 2 3 4 MAINTENANCE D-3 D-3 Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC FIGURE D.1 – MAJOR COMPONENT LOCA TIONS 1. Molded Case Assembly 2.
LN-15 NOTES D-4 D-4 Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC.
Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC LN-15 Section E-1 Section E-1 Theory of Operation ...............................................................................................Section E General Description .
FIGURE E.2 – GENERAL DESCRIPTION & INPUT POWER CONT ACTOR ELECTRODE INPUT VOL T AGE TOROID ASSEMBL Y FULL WAVE BRIDGE WORK SENSING LEAD ON/OFF SWITCH MOV BOOST POWER SUPPL Y BOARD FEED HEAD BOAR.
LN-15 THEOR Y OF OPERA TION TRIGGER AND CONTROL CIRCUITS When the gun trigger is closed (activated) the Feed Head Board is “signaled” to apply armatur e voltage to the drive motor , activate the gas solenoid and close the LN-15 internal contactor .
LN-15 .THEOR Y OF OPERA TION E-4 E-4 Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC FIGURE E.
THEOR Y OF OPERA TION DISPLA Y BOARD The Display Board pr ovides information to the user through digital displays and LED’ s. The Display Board communicates with the Feed Head Board via the SPI Bus cable. The wire feed speed display shows the rate that the LN-15 will feed wire during the welding pr ocess.
LN-15 NOTES E-6 E-6 Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC.
Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC LN-15 Section F-1 Section F-1 T ABLE OF CONTENTS - TROUBLESHOOTING & REP AIR SECTION - Tr oubleshooting & Repair Section ......................................
HOW TO USE TROUBLESHOOTING GUIDE Service and repair should be performed by only Lincoln Electric Factory T rained Personnel. Unauthorized repairs performed on this equipment may r esult in danger to the technician and machine operator and will invalidate your factory warranty .
LN-15 Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC TROUBLESHOOTING & REP AIR F-3 F-3 Sometimes machine failures appear to be due to PC board failures.
Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC TROUBLESHOOTING & REP AI.
Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC TROUBLESHOOTING & REP AIR F-5 F-5 TROUBLESHOOTING GUIDE Observe Safety Guidelines detailed in the beginning of this manual.
Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC LN-15 TROUBLESHOOTING & .
Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC LN-15 TROUBLESHOOTING & .
Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC LN-15 TROUBLESHOOTING & REP AIR F-8 F-8 PROBLEMS (SYMPTOMS) POSSIBLE AREAS OF MISADJUSTMENT(S) RECOMMENDED COURSE OF ACTION WELDING PROBLEMS No shielding gas.
LN-15 Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC RESOLUTION DESCRIPTION/ DEFINITION 0081 0082 0086 A verage motor over cur- r ent shutdown Locked rotor condition on the wire drive motor .
LN-15 NOTES F-10 F-10 Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC.
Service and repair should be performed by only Lincoln Electric factory trained personnel. Unauthorized repairs performed on this equipment may result in danger to the technician or machine operator and will invalidate your factory warranty .
LN-15 F-12 F-12 Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC TROUBLESHOOTING & REP AIR TEST PROCEDURE 1. Remove input power to the LN-15.
LN-15 F-13 F-13 Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC TROUBLESHOOTING & REP AIR C9 C10 J47 + - + - R2 R1 R71 R72 R14 R15 R16 FIGURE F .
LN-15 NOTES F-14 F-14 Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC.
LN-15 F-15 F-15 Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC TROUBLESHOOTING AND REP AIR Service and repair should be performed by only Lincoln Electric factory trained personnel.
LN-15 F-16 F-16 Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC TROUBLESHOOTING AND REP AIR GAS SOLENOID LEADS 552 &553 GAS SOLENOID V AL VE TEST (continued) FIGURE F .
LN-15 F-17 F-17 Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC TROUBLESHOOTING AND REP AIR Service and repair should be performed by only Lincoln Electric factory trained personnel.
LN-15 F-18 F-18 Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC TROUBLESHOOTING AND REP AIR LARGE TERMINAL STUDS LEADS 507 & 578 (blue) CONT ACTOR TEST (continued) FIGURE F .
LN-15 F-19 F-19 Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC TROUBLESHOOTING AND REP AIR Service and repair should be performed by only Lincoln Electric factory trained personnel.
LN-15 F-20 F-20 Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC LEADS 550 & 551 TEST PROCEDURE 1. Remove the input power to the LN-15.
LN-15 F-21 F-21 Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC TROUBLESHOOTING AND REP AIR Service and repair should be performed by only Lincoln Electric factory trained personnel.
Blue (562) Red (563) Black (561) LN-15 F-22 F-22 Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC TEST PROCEDURE 1. Remove the input power to the LN-15.
LN-15 F-23 F-23 Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC TROUBLESHOOTING AND REP AIR Service and repair should be performed by only Lincoln Electric factory trained personnel.
LN-15 F-24 F-24 Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC REMOV AL PROCEDURE 1. Remove the input power to the LN-15. 2. Perform the Roll Cage Removal Procedure.
LN-15 F-25 F-25 Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC REPLACEMENT PROCEDURE 1. Install the new contactor using the four screws previously removed.
LN-15 NOTES F-26 F-26 Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC.
LN-15 F-27 F-27 Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC TROUBLESHOOTING AND REP AIR Service and repair should be performed by only Lincoln Electric factory trained personnel.
LN-15 F-28 F-28 Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC TROUBLESHOOTING AND REP AIR FEED HEAD CONTROL BOARD REMOV AL AND REPLACEMENT PROCEDURE (Continued) Figure F .
LN-15 F-29 F-29 Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC TROUBLESHOOTING AND REP AIR FEED HEAD CONTROL BOARD REMOV AL AND REPLACEMENT PROCEDURE (Continued) Figure F .
LN-15 NOTES F-30 F-30 Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC.
LN-15 F-31 F-31 Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC TROUBLESHOOTING AND REP AIR Service and repair should be performed by only Lincoln Electric factory trained personnel.
LN-15 F-32 F-32 Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC TROUBLESHOOTING AND REP AIR BOOST POWER SUPPL Y BOARD REMOV AL AND REPLACEMENT PROCEDURE (Continued) Figure F .
LN-15 F-33 F-33 Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC TROUBLESHOOTING AND REP AIR BOOST POWER SUPPL Y BOARD REMOV AL AND REPLACEMENT PROCEDURE (Continued) Figure F .
LN-15 NOTES F-34 F-34 Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC.
LN-15 F-35 F-35 Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC TROUBLESHOOTING AND REP AIR Service and repair should be performed by only Lincoln Electric factory trained personnel.
LN-15 F-36 F-36 Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC TROUBLESHOOTING AND REP AIR WIRE DRIVE ASSEMBL Y REMOV AL AND REPLACEMENT PROCEDURE (Continued) Figure F .
LN-15 F-37 F-37 Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC TROUBLESHOOTING AND REP AIR Service and repair should be performed by only Lincoln Electric factory trained personnel.
LN-15 F-38 F-38 Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC TROUBLESHOOTING AND REP AIR COVER AND SPINDLE MOUNT REMOV AL AND REPLACEMENT PROCEDURE (Continued) Figure F .
LN-15 F-39 F-39 Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC TROUBLESHOOTING AND REP AIR COVER AND SPINDLE MOUNT REMOV AL AND REPLACEMENT PROCEDURE (Continued) REPLACEMENT PROCEDURE 1.
LN-15 F-40 F-40 Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC NOTES.
LN-15 F-41 F-41 Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC TROUBLESHOOTING AND REP AIR Service and repair should be performed by only Lincoln Electric factory trained personnel.
LN-15 F-42 F-42 Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC TROUBLESHOOTING AND REP AIR ROLL CAGE REMOV AL AND REPLACEMENT PROCEDURE (Continued) Figure F .
LN-15 TROUBLESHOOTING AND REP AIR F-43 F-43 Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Retur.
LN-15 NOTES F-44 F-44 Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC.
Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC LN-15 Section G-1 Section G-1 T ABLE OF CONTENTS - ELECTRICAL DIAGRAMS SECTION - Electrical Diagrams ..................................................................
ELECTRICAL DIAGRAMS G-2 LN-15 WIRING DIAGRAM - ENTIRE MACHINE - (L1 1436-1) PRINT TO 8.5 X 11.0 LN- 15 ACR OSS THE ARC M OD EL CLEVE LAND, OHIO U.S.A. L11436-1 A J1,J86 CAVITY NU MB ER ING SEQUENCE (COMPONENT SIDE OF P.
Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC ELECTRICAL DIAGRAMS G-3 LN-15 SCHEMA TIC - ENTIRE MACHINE - (G4198-1) EN-170 S O L I D E D G E G419 8- 1 LN-15 (ACROSS THE ARC) MACHINE SCHEMATIC NONE G4198 E.
ELECTRICAL DIAGRAMS G-4 LN-15 SCHEMA TIC - BOOST PC BOARD - (L1 1818-2) G-4 NOTE: This diagram is for reference only . It may not be accurate for all machines covered by this manual.
NOTE: Lincoln Electric assumes no responsibility for liablilities resulting from board level troubleshooting. PC Board repairs will invalidate your factory warranty . Individual Printed Circuit Board Components are not available from Lincoln Electric.
ELECTRICAL DIAGRAMS G-6 LN-15 SCHEMA TIC - FEEDHEAD P .C. BOARD - (G3883-1E0/1) G-6 NOTE: This diagram is for reference only . It may not be accurate for all machines covered by this manual.
ELECTRICAL DIAGRAMS G-7 LN-15 SCHEMA TIC - FEEDHEAD P .C. BOARD - (G3883-1E0/2) G-7 NOTE: This diagram is for reference only . It may not be accurate for all machines covered by this manual.
NOTE: Lincoln Electric assumes no responsibility for liablilities resulting from board level troubleshooting. PC Board repairs will invalidate your factory warranty . Individual Printed Circuit Board Components are not available from Lincoln Electric.
ELECTRICAL DIAGRAMS G-9 LN-15 SCHEMA TIC - SPI DISPLA Y P .C. BOARD - (L1 1756-1E1) G-9 NOTE: This diagram is for reference only . It may not be accurate for all machines covered by this manual.
NOTE: Lincoln Electric assumes no responsibility for liablilities resulting from board level troubleshooting. PC Board repairs will invalidate your factory warranty . Individual Printed Circuit Board Components are not available from Lincoln Electric.
SVM ERROR REPORTING FORM We need to know if there are errors in our manuals. We also value any suggestions as to additional tests or procedures that would make this SVM a better tool for you.
An important point after buying a device Lincoln Electric SVM166-A (or even before the purchase) is to read its user manual. We should do this for several simple reasons:
If you have not bought Lincoln Electric SVM166-A yet, this is a good time to familiarize yourself with the basic data on the product. First of all view first pages of the manual, you can find above. You should find there the most important technical data Lincoln Electric SVM166-A - thus you can check whether the hardware meets your expectations. When delving into next pages of the user manual, Lincoln Electric SVM166-A you will learn all the available features of the product, as well as information on its operation. The information that you get Lincoln Electric SVM166-A will certainly help you make a decision on the purchase.
If you already are a holder of Lincoln Electric SVM166-A, but have not read the manual yet, you should do it for the reasons described above. You will learn then if you properly used the available features, and whether you have not made any mistakes, which can shorten the lifetime Lincoln Electric SVM166-A.
However, one of the most important roles played by the user manual is to help in solving problems with Lincoln Electric SVM166-A. Almost always you will find there Troubleshooting, which are the most frequently occurring failures and malfunctions of the device Lincoln Electric SVM166-A along with tips on how to solve them. Even if you fail to solve the problem, the manual will show you a further procedure – contact to the customer service center or the nearest service center