Instruction/ maintenance manual of the product RANGER 3PHASE SVM207-A Lincoln Electric
Go to page of 94
S VM207 -A Jan uar y , 20 1 1 Safety Depends on Y ou Lincoln arc welding and cutting equipment is designed and built with safety in mind. However , your overall safety can be increased by proper installation . . . and thoughtful operation on your part.
RANGER® 3 PHASE SAFETY i i FOR ENGINE powered equipment. 1.a. T urn the engine off before troubleshooting and maintenance work unless the maintenance work requires it to be running. ____________________________________________________ 1.b.Operate engines in open, well-ventilated areas or vent the engine exhaust fumes outdoors.
SAFETY ii ii RANGER® 3 PHASE FUMES AND GASES can be dangerous. 5.a. Welding may produce fumes and gases hazardous to health. Avoid breathing these fumes and gases.When welding, keep your head out of the fume. Use enough ventilation and/or exhaust at the arc to keep fumes and gases away from the breathing zone.
RANGER® 3 PHASE SAFETY iii iii FOR ELECTRICALL Y powered equipment. 8.a. Turn off input power using the disconnect switch at the fuse box before working on the equipment. 8.b. Install equipment in accordance with the U.S. National Electrical Code, all local codes and the manufacturer ’s recommendations.
SAFETY iv iv RANGER® 3 PHASE PRÉCAUTIONS DE SÛRETÉ Pour votre propre protection lire et observer toutes les instructions et les précautions de sûreté specifiques qui parraissent dans ce manuel aussi bien que les précautions de sûreté générales suiv- antes: Sûreté Pour Soudage A L ’Arc 1.
S AFETY Electromagnetic Compatibility (EMC) Confor mance P roducts displaying the CE mark are in conformity with European Community Council Directiv e of 1 5 Dec 2004 on the appro ximation of the laws of the Member States relating to electromagnetic compatibilit y , 2004/1 08/EC .
S AFETY Electromagnetic Compatibility (EMC) The size of the surrounding area to be considered will depend on the structure of the building and other activities that are taking place. The surrounding area ma y e xtend bey ond the boundar ies of the premises.
- MASTER T ABLE OF CONTENTS FOR ALL SECTIONS - I I RANGER® 3 PHASE Page Safety . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .i-iv Installation . . .
T ABLE OF CONTENTS - INST ALLA TION SECTION A-1 A-1 RANGER® 3 PHASE Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .A-1 T echnical Specifications .
INST ALLA TION A-2 A-2 RANGER® 3 PHASE TECHNICAL SPECIFICA TIONS - RANGER® 3 PHASE (K2337-1 & K2337-2) INPUT - GASOLINE ENGINE RA TED OUTPUT @ 104°F (40°C)- WELDER HEIGHT WIDTH DEPTH WEIGHT 30.
INST ALLA TION A-3 A-3 RANGER® 3 PHASE SAFETY PRECAUTIONS MACHINE GROUNDING Because this portable engine driven welder / generator creates it’s own power , it is not necessary to connect it’s frame to an earth ground, unless the machine is connected to premises wiring (your home, shop, etc.
INST ALLA TION A-4 A-4 RANGER® 3 PHASE FUEL Fill the fuel tank with clean, fresh, lead-free gasoline. Observe fuel gauge while filling to prevent overfilling. OIL The RANGER® 3 PHASE is shipped with the engine crankcase filled with SAE 10W-30 oil. Check the oil level before starting the engine.
INST ALLA TION A-5 A-5 RANGER® 3 PHASE WELDING OUTPUT CABLES With the engine off, connect the electrode and work cables to the studs provided. These connections should be checked periodically and tightened if neces- sary . Loose connections will result in overheating of the output studs.
INST ALLA TION A-6 A-6 RANGER® 3 PHASE LOCA TION / VENTILA TION The welder should be located to provide an unrestrict- ed flow of clean, cool air to the cooling air inlets and to avoid heated air coming out of the welder recirculating back to the cooling air inlet.
INST ALLA TION A-7 A-7 RANGER® 3 PHASE 120 V GFCI DUPLEX RECEPT ACLES A GFCI (Ground Fault Circuit Interrupter) electrical receptacle is a device to protect against electric shock should a piece of defective equipment connected to it develop a ground fault.
INST ALLA TION A-8 A-8 RANGER® 3 PHASE All auxiliary power is protected by circuit breakers with the following values: The 120V has 20 amp circuit breakers for each duplex receptacle. The 240V has 50 amp circuit breakers for each hot lead going the 240V receptacle.
INST ALLA TION A-9 A-9 RANGER® 3 PHASE 240 Volt 60 Hz. 3-Wire Service POWER COMPANY METER 240 VOLT 120 VOLT 120 VOLT LOAD N NEUTRAL BUS GROUND PREMISES DISCONNECT AND SERVICE OVERCURRENT PROTECTION GND N NOTE: No. 6 COPPER CONDUCTOR CABLE SEE NATIONAL ELECTRICAL CODE FOR ALTERNATE WIRE SIZE RECOMMENDATIONS.
INST ALLA TION A-10 A-10 RANGER® 3 PHASE RANGER® 3 PHASE Extension Cord Length Recommendations (Use the shortest length extension cord possible sized per the following table.) Maximum Allowable Cord Length in ft. (m) for Conductor Size Conductor size is based on maximum 2.
T ABLE OF CONTENTS - OPERA TION SECTION B-1 B-1 RANGER® 3 PHASE Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .B-1 Safety Precautions .
OPERA TION B-2 B-2 RANGER® 3 PHASE WELDER CONTROLS - FUNCTION AND OPERA TION ENGINE SWITCH The engine switch is used to Start the Engine, Select High Idle or Auto Idle while the engine is running, and stop the Engine. When placed in the “OFF” position, the ignition circuit is de-energized to shut down the engine.
OPERA TION B-3 B-3 RANGER® 3 PHASE “ RANGE” SWITCH The “Range” switch is used to select one of three amperage ranges with generous overlap for Stick/TIG welding, or one Wire Feed welding range. Never change the “RANGE” Switch setting while welding.
OPERA TION B-4 B-4 RANGER® 3 PHASE WELDING PROCESS For any electrodes the procedures should be kept with- in the rating of the machine. For electrode information see the appropriate Lincoln publication. STICK (CONST ANT CURRENT) WELDING Connect welding cables to the "T O WORK” and "ELECTRODE” studs.
OPERA TION B-5 B-5 RANGER® 3 PHASE SUMMAR Y OF WELDING PROCESSES C O N T RO L E LE CT R O D E C A B L E I DL E W HE N N OT T O S T AR T P R O C ES S U SE D M OD E W EL DI NG WE LD IN G STICK No AUTO Hot T ouch electrode to work. Welding starts immediately and engine goes to high idle.
OPERA TION B-6 B-6 RANGER® 3 PHASE ST ARTING/SHUTDOWN INSTRUCTIONS ST ARTING THE ENGINE Be sure all Pre-Operation Maintenance has been per- formed. Also, read the Engine Owner ’s Manual before starting for the first time. Remove all loads connected to the AC power recepta- cles.
T ABLE OF CONTENTS - ACCESSORIES SECTION C-1 C-1 RANGER® 3 PHASE Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .C-1 Optional Equipment .
ACCESSORIES C-2 C-2 RANGER® 3 PHASE OPTIONAL EQUIPMENT (Field Installed) K957-1 HEA VY DUTY , TWO WHEEL TRAILER FOR SMALL WELDERS - For road, off-road and in-plant and yard towing. (For highway use, consult applicable federal, state and local laws regarding requirements for brakes, lights, fenders, etc.
ACCESSORIES C-3 C-3 RANGER® 3 PHASE RECOMMENDED EQUIPMENT STICK K704 Accessory Kit which includes: • Electrode Holder & Cable • Work Clamp & Cable • Headshield WIRE FEED LN-25 K449 LN-25 - Includes internal contactor for across the arc operation (no control cable).
NOTES C-4 C-4 RANGER® 3 PHASE Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master T.
T ABLE OF CONTENTS - MAINTENANCE SECTION D-1 D-1 RANGER® 3 PHASE Maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .D-1 Safety Precautions .
MAINTENANCE D-2 D-2 RANGER® 3 PHASE Have qualified personnel do the maintenance work. T urn the engine off before working inside the machine. In some cases, it may be necessary to remove safety guards to perform required maintenance. Remove guards only when necessary and replace them when the mainte- nance requiring their removal is complete.
MAINTENANCE D-3 D-3 RANGER® 3 PHASE Use 4-stroke motor oil that meets or exceeds the requirements for API service classification SG or SH. Always check the API SERVICE label on the oil con- tainer to be sure it includes the letters SG or SH. SAE 10W-30 is recommended for general, all-tempera- ture use, -5 F to 104 F (-20 C to 40 C).
MAINTENANCE D-4 D-4 RANGER® 3 PHASE BA TTER Y 1. When replacing, jumping, or otherwise connecting the battery to the battery cables, the proper polarity must be observed. Failure to observe the proper polarity could result in damage to the charging circuit.
MAINTENANCE D-5 D-5 RANGER® 3 PHASE FIGURE D.1 - MAJOR COMPONENT LOCA TION 1. CASEFRONT 2. OUTPUT RECTIFIER ASSEMBL Y 3. BASE/UNDERCARRIAGE ASSEMBL Y 4.
NOTES D-6 D-6 RANGER® 3 PHASE Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master T.
T ABLE OF CONTENTS-THEOR Y OF OPERA TION SECTION E-1 E-1 RANGER® 3 PHASE Theory of Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .E-1 General Description .
THEOR Y OF OPERA TION E-2 E-2 RANGER® 3 PHASE FIGURE E.2 - ENGINE COMPONENTS AND OPERA TION NOTE: Unshaded areas of Block Logic Diagram are the subject of discussion GENERAL DESCRIPTION The RANGER® 3 PHASE is a twin cylinder , gasoline driven, multiprocess arc welder and AC power genera- tor .
THEOR Y OF OPERA TION E-3 E-3 RANGER® 3 PHASE FIGURE E.2 - ROTOR, ST A TOR AND CONTROL CIRCUITS NOTE: Unshaded areas of Block Logic Diagram are the subject of discussion IDLER SOL ENO ID OUTPUT CONTR.
THEOR Y OF OPERA TION E-4 E-4 RANGER® 3 PHASE FIGURE E.2 - WELD CIRCUITR Y NOTE: Unshaded areas of Block Logic Diagram are the subject of discussion WELD CIRCUITR Y One end of the Weld Winding is connected to the Output Rectifier and at the other end to the Reactor .
T ABLE OF CONTENTS - TROUBLESHOOTING AND REP AIR F-1 F-1 RANGER® 3 PHASE T roubleshooting and Repair . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .F-1 How to Use Troubleshooting Guide .
TROUBLESHOOTING AND REP AIR F-2 F-2 RANGER® 3 PHASE This T roubleshooting Guide is provided to help you locate and repair possible machine malfunctions. Simply follow the three-step procedure listed below . Step 1. LOCA TE PROBLEM (SYMPTOM). Look under the column labeled “PROBLEM (SYMPTOMS)”.
TROUBLESHOOTING AND REP AIR F-3 F-3 RANGER® 3 PHASE Sometimes machine failures appear to be due to PC board failures. These problems can sometimes be traced to poor electrical connections. T o avoid prob- lems when troubleshooting and replacing PC boards, please use the following procedure: 1.
OUTPUT PROBLEMS Observe Safety Guidelines detailed in the beginning of this manual. PROBLEMS (SYMPTOMS) POSSIBLE AREAS OF MISADJUSTMENT(S) RECOMMENDED COURSE OF ACTION If for any reason you do not und.
OUTPUT PROBLEMS Observe Safety Guidelines detailed in the beginning of this manual. PROBLEMS (SYMPTOMS) POSSIBLE AREAS OF MISADJUSTMENT(S) RECOMMENDED COURSE OF ACTION If for any reason you do not und.
OUTPUT PROBLEMS Observe Safety Guidelines detailed in the beginning of this manual. PROBLEMS (SYMPTOMS) POSSIBLE AREAS OF MISADJUSTMENT(S) RECOMMENDED COURSE OF ACTION If for any reason you do not und.
ENGINE PROBLEMS Observe Safety Guidelines detailed in the beginning of this manual. PROBLEMS (SYMPTOMS) POSSIBLE AREAS OF MISADJUSTMENT(S) RECOMMENDED COURSE OF ACTION If for any reason you do not und.
ENGINE PROBLEMS Observe Safety Guidelines detailed in the beginning of this manual. PROBLEMS (SYMPTOMS) POSSIBLE AREAS OF MISADJUSTMENT(S) RECOMMENDED COURSE OF ACTION If for any reason you do not und.
ENGINE PROBLEMS Observe Safety Guidelines detailed in the beginning of this manual. PROBLEMS (SYMPTOMS) POSSIBLE AREAS OF MISADJUSTMENT(S) RECOMMENDED COURSE OF ACTION If for any reason you do not und.
WELDING PROBLEMS Observe Safety Guidelines detailed in the beginning of this manual. PROBLEMS (SYMPTOMS) POSSIBLE AREAS OF MISADJUSTMENT(S) RECOMMENDED COURSE OF ACTION If for any reason you do not un.
Service and repair should be performed only by Lincoln Electric factory trained personnel. Unauthorized repairs performed on this equipment may result in danger to the technician or machine operator and will invalidate your factory warranty .
Slip Rings Brushes Lead 219 + - Lead 200A FIGURE F .1 – SLIP RINGS AND BRUSHES ROT OR VOL T AGE TEST (continued) TEST PROCEDURE 1. Using a 5/16” nut driver or socket, remove the 6 sheet metal screws from the case top. 2. Remove the rubber gasket (cover seal) from the lift bail.
Service and repair should be performed only by Lincoln Electric factory trained personnel. Unauthorized repairs performed on this equipment may result in danger to the technician or machine operator and will invalidate your factory warranty .
Lead 219 Lead 200A + - FIGURE F .2 – SLIP RINGS ROTOR RESIST ANCE TEST (continued) TEST PROCEDURE 1. With a 5/16” nut driver or socket, remove the 6 sheet metal screws from the case top. 2. Remove the rubber gasket (cover seal) from the lift bail.
Service and repair should be performed only by Lincoln Electric factory trained personnel. Unauthorized repairs performed on this equipment may result in danger to the technician or machine operator and will invalidate your factory warranty .
120 V AC GFCI RECEPT ACLE 120/240 V AC 1 PHASE RECEPT ACLE 480 V AC 3 PHASE RECEPT ACLE TEST RESET Lead #3 Lead #5 Lead #6 Lead #3 Z YX GND FIGURE F .3 – RECEPT ACLES AND LEADS AUXILIAR Y AND FIELD .
FIGURE F .4 – CONTROL PC BOARD AUXILIAR Y AND FIELD WINDING TEST (continued) FIELD WINDING 1. Remove the fuel cap and lift bail rubber gasket. With a 5/16” nut driver or socket, remove the case top and left side; then reinstall the fuel cap. 2. Connect the volt/ohmmeter probes to leads #7 and #9 where they connect to the Control P .
NOTES F-18 F-18 RANGER® 3 PHASE Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master.
Service and repair should be performed only by Lincoln Electric factory trained personnel. Unauthorized repairs performed on this equipment may result in danger to the technician or machine operator and will invalidate your factory warranty .
(—) (+) TO POLARITY SWITCH (S2) LEAD 8 TO CHOKE (L1) LEAD 254 TO ST A TOR (LEAD W1) TO ST A TOR (LEAD S2) TO RANGE SWITCH (S1) AC2 AC1 FIGURE F .5 – OUTPUT RECTIFIER OUTPUT RECTIFIER BRIDGE TEST (continued) TEST PROCEDURE 1. Remove the spark plug wires to prevent accidental engine kickback or starting.
Service and repair should be performed only by Lincoln Electric factory trained personnel. Unauthorized repairs performed on this equipment may result in danger to the technician or machine operator and will invalidate your factory warranty .
B A D C CONTROL L1219 8-1 X4 DZ5 D1 C24 C39 R4 D2 X3 C31 R33 R76 R95 R82 R39 Q3 R47 C12 R 72 R 67 C37 R88 R45 J2 R48 D3 C30 C32 DZ8 D11 D 10 C2 R5 TP2 D21 R73 D9 DZ2 DZ10 R11 Q1 R 16 DZ9 R10 Q5 R52 R8.
Service and repair should be performed only by Lincoln Electric factory trained personnel. Unauthorized repairs performed on this equipment may result in danger to the technician or machine operator and will invalidate your factory warranty .
V oltage Regulator AC Lead DC Lead AC Lead FIGURE F .1 – DOOR REMOV AL CHARGING CIRCUIT TEST (continued) TEST PROCEDURE 1. Start the engine and run it at high idle (3650 RPM). 2. Set the voltmeter for AC volts and place one meter probe on each of the two outside leads that attach to the engine voltage regulator .
Service and repair should be performed only by Lincoln Electric factory trained personnel. Unauthorized repairs performed on this equipment may result in danger to the technician or machine operator and will invalidate your factory warranty .
Blower Paddle FIGURE F .6 – BLOWER P ADDLE MARKED FOR STROBE-T ACH METHOD ENGINE THROTTLE ADJUSTMENT TEST (continued) TEST PROCEDURE This test can be conducted by any one of four meth- ods. Strobe-tach Method: 1. With the 5/16” nut driver , remove the 6 sheet metal screws from the case top.
Throttle linkage Choke Cable 3/8" High Idle Adjustment Nut FIGURE F .7 HIGH IDLE ADJUSTMENT NUT ENGINE THROTTLE ADJUSTMENT TEST (continued) Frequency Counter Method 1. Plug the frequency counter into one of the 1 15 V AC auxiliary receptacles. 2.
FIGURE F .9 - 1 15V AC SUPPL Y W A VEFORM (HIGH IDLE- NO LOAD) ENGINE THROTTLE ADJUSTMENT TEST (continued) Oscilloscope Method: 1. Connect the oscilloscope to the 1 15 V AC recepta- cle, according to the manufacturer ’s instructions. At 3700 RPM, the waveform should exhibit a peri- od of 16.
TROUBLESHOOTING AND REP AIR F-29 F-29 RANGER® 3 PHASE CH1 0 volts 5 ms 50 volts SCOPE SETTINGS V olts/Div .....................50V/Div . Horizontal Sweep .....5 ms/Div . Coupling .............................DC T rigger .........................Internal This is the typical AC output voltage generated from a properly operating machine.
TROUBLESHOOTING AND REP AIR F-30 F-30 RANGER® 3 PHASE This is the typical CV output voltage generated from a properly operating machine. Note that each vertical divi- sion represents 20 volts and that each horizontal division represents 5 mil- liseconds in time.
TROUBLESHOOTING AND REP AIR F-31 F-31 RANGER® 3 PHASE This is the typical DC output voltage generated from a properly operating machine. Note that each vertical divi- sion represents 20 volts and that each horizontal division represents 5 mil- liseconds in time.
TROUBLESHOOTING AND REP AIR F-32 F-32 RANGER® 3 PHASE This is the typical AC output voltage generated from a properly operating machine. Note that each vertical divi- sion represents 20 volts and that each horizontal division represents 5 mil- liseconds in time.
TROUBLESHOOTING AND REP AIR F-33 F-33 RANGER® 3 PHASE This is NOT the typical CV output volt- age waveform. One output diode is not functioning. Note the “gap” in the waveform. One output diode was dis- connected to simulate an open or non- functioning output diode.
TROUBLESHOOTING AND REP AIR F-34 F-34 RANGER® 3 PHASE This is NOT the typical DC (+) output voltage waveform. One output diode is not functioning. Note the “gap” in the waveform. One output diode was disconnected to simulate an open or nonfunctioning output diode.
TROUBLESHOOTING AND REP AIR F-35 F-35 RANGER® 3 PHASE This is the typical CV output voltage generated from a properly operating machine. Note that each vertical divi- sion represents 20 volts and that each horizontal division represents 5 mil- liseconds in time.
TROUBLESHOOTING AND REP AIR F-36 F-36 RANGER® 3 PHASE This is the typical DC output voltage generated from a properly operating machine. Note that each vertical divi- sion represents 50 volts and that each horizontal division represents 5 mil- liseconds in time.
TROUBLESHOOTING AND REP AIR F-37 F-37 RANGER® 3 PHASE This is the typical auxiliary output volt- age generated from a properly operat- ing machine. Note that each vertical division represents 50 volts and that each horizontal division represents 5 milliseconds in time.
NOTES F-38 F-38 RANGER® 3 PHASE Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master.
Service and repair should be performed only by Lincoln Electric factory trained personnel. Unauthorized repairs performed on this equipment may result in danger to the technician or machine operator and will invalidate your factory warranty .
BRUSH REMOV AL AND REPLACEMENT PROCEDURE (continued) PROCEDURE 1. Remove the spark plug wires. 2. With a 5/16” nut driver or socket, remove the 6 sheet metal screws from the case top. 3. Remove the rubber gasket (cover seal) from the lift bail. 4. Remove the fuel cap.
7/16" Brush Assembly Bracket Bolts FIGURE F .9 – BRUSH HOLDER MOUNTING BOL TS BRUSH REMOV AL AND REPLACEMENT PROCEDURE (continued) TROUBLESHOOTING AND REP AIR F-41 F-41 RANGER® 3 PHASE Return .
NOTES F-42 F-42 RANGER® 3 PHASE Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master.
Service and repair should be performed only by Lincoln Electric factory trained personnel. Unauthorized repairs performed on this equipment may result in danger to the technician or machine operator and will invalidate your factory warranty .
PROCEDURE Before starting the following procedure, refer to the topic “PC Board Troubleshooting Procedures” at the beginning of this section. 1. Remove the engine spark plug wires. 2. With a 5/16” nut driver or socket, remove the 6 sheet metal screws from the case top.
Service and repair should be performed only by Lincoln Electric factory trained personnel. Unauthorized repairs performed on this equipment may result in danger to the technician or machine operator and will invalidate your factory warranty .
(—) (+) TO POLARITY SWITCH (S2) LEAD 8 TO CHOKE (L1) LEAD 254 TO ST A TOR (LEAD W1) TO ST A TOR (LEAD S2) TO RANGE SWITCH (S1) AC2 AC1 FIGURE F .1 1 – OUTPUT RECTIFIER OUTPUT RECTIFIER BRIDGE REMOV AL AND REPLACEMENT PROCEDURE (continued) PROCEDURE 1.
Service and repair should be performed only by Lincoln Electric factory trained personnel. Unauthorized repairs performed on this equipment may result in danger to the technician or machine operator and will invalidate your factory warranty .
3 3 4 4 8 8 10A 10A 9 9 7 7 5B 5B 1B 1B 1C 1C 1A 1A 10B 10B 10C 10C 2 2 6 6 5A 5A FIGURE F .12 – ENGINE/ROTOR COMPONENT LOCA TIONS ENGINE/ROTOR REMOV AL AND REPLACEMENT PROCEDURE (cont.) TROUBLESHOOTING AND REP AIR F-48 F-48 RANGER® 3 PHASE 1A. T olerance Ring 1B.
ENGINE/ROTOR REMOV AL AND REPLACEMENT PROCEDURE (cont.) PROCEDURE 1. Refer to Figure F .12 for component locations. 2. Remove the engine spark plug wires. 3. With a 5/16” nut driver or socket, remove the 6 sheet metal screws from the case top. 4. Remove the rubber gasket (cover seal) from the lift bail.
ROTOR THRU-BOL T FIGURE F .13 - ENGINE AND ROTOR REMOVED FROM ST A TOR ENGINE/ROTOR REMOV AL AND REPLACEMENT PROCEDURE (cont.) ROTOR REMOV AL PROCEDURE 1. T o remove the rotor , double check that the engine spark plug wires are disconnected. Y ou will be turn- ing the rotor during this procedure, and this could accidentally cause engine kickback.
ENGINE/ROTOR REMOV AL AND REPLACEMENT PROCEDURE (cont.) REASSEMBL Y PROCEDURE NOTE: Lincoln Electric recommends that a new bear- ing be installed when you replace the rotor and blower assembly . 1. Clean the tapered engine crankshaft. Slide the rotor onto the shaft.
RETEST AFTER REP AIR TROUBLESHOOTING AND REP AIR F-52 F-52 RANGER® 3 PHASE Retest a machine: • If it is rejected under test for any reason that requires you to remove any mechanical part which could affect the machine’s electrical characteristics.
T ABLE OF CONTENTS - DIAGRAM SECTION G-1 G-1 RANGER® 3 PHASE Electrical Diagrams . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .G-1 Wiring Diagram Complete Machine (M20315) .
ElEcTrical DiaGramS G-2 raNGEr® 3 phaSE WiriNG DiaGram - cOmplETE machiNE - m20315 ST ART ER CR1 ST ART ER SOLENOI D 1 2 VO LT IDLER SOLENOID BA TT ERY AC AC B+ SWI TCH REG ULA T OR FL Y WHEEL A LT ER NATOR B- HO UR ME T ER 5E 5D 224 ENGINE CO MPO NE NTS 22 4A 1 2 3 CO N NE CTOR PIN N UMBE RS: 7 6 12 1 2 3 4 J1 N.
ElEcTrical DiaGramS G-3 raNGEr® 3 phaSE SchEma Tic - cOmplETE machiNE - l12259 L12259 RANGER 3 PHASE KOHLER MACHINE SCHEMATIC NONE L12249 BAM BAM - U NLESS OTHERW ISE SPE C IF IE D TOLERA N CE MANUFACTURIN G TOLERANCE PER E2056 ON 2 PLACE DECIMA LS IS ± .
ElEcTrical DiaGramS G-4 raNGEr® 3 phaSE SchEma Tic - cONTrOl pc bOarD - l12197-1 G-4 NOTE: This diagram is for reference only. It may not be accurate for all machines covered by this manual.
An important point after buying a device Lincoln Electric RANGER 3PHASE SVM207-A (or even before the purchase) is to read its user manual. We should do this for several simple reasons:
If you have not bought Lincoln Electric RANGER 3PHASE SVM207-A yet, this is a good time to familiarize yourself with the basic data on the product. First of all view first pages of the manual, you can find above. You should find there the most important technical data Lincoln Electric RANGER 3PHASE SVM207-A - thus you can check whether the hardware meets your expectations. When delving into next pages of the user manual, Lincoln Electric RANGER 3PHASE SVM207-A you will learn all the available features of the product, as well as information on its operation. The information that you get Lincoln Electric RANGER 3PHASE SVM207-A will certainly help you make a decision on the purchase.
If you already are a holder of Lincoln Electric RANGER 3PHASE SVM207-A, but have not read the manual yet, you should do it for the reasons described above. You will learn then if you properly used the available features, and whether you have not made any mistakes, which can shorten the lifetime Lincoln Electric RANGER 3PHASE SVM207-A.
However, one of the most important roles played by the user manual is to help in solving problems with Lincoln Electric RANGER 3PHASE SVM207-A. Almost always you will find there Troubleshooting, which are the most frequently occurring failures and malfunctions of the device Lincoln Electric RANGER 3PHASE SVM207-A along with tips on how to solve them. Even if you fail to solve the problem, the manual will show you a further procedure – contact to the customer service center or the nearest service center