Instruction/ maintenance manual of the product IM402-B Lincoln Electric
Go to page of 21
IDEALARC ® A C/DC 250 OPERA TOR’S MANUAL For use with machines having Code Number 9491 thru 11104. IM402-B August, 2007 Safety Depends on You Lincoln arc welding and cutting equipment is designed and built with safety in mind. However, your overall safety can be increased by proper installation .
FOR ENGINE powered equipment. 1.a. Turn the engine off before troubleshooting and maintenance work unless the maintenance work requires it to be running. ____________________________________________________ 1.b. Operate engines in open, well-ventilated areas or vent the engine exhaust fumes outdoors.
ii SAFETY ii ARC RA YS can burn. 4.a. Use a shield with the proper filter and cover plates to protect your eyes from sparks and the rays of the arc when welding or observing open arc welding. Headshield and filter lens should conform to ANSI Z87. I standards.
iii SAFETY iii FOR ELECTRICALL Y powered equipment. 8.a. Turn off input power using the disconnect switch at the fuse box before working on the equipment. 8 . b. Install equipment in accordance with the U.S. National Electrical Code, all local codes and the manufacturerʼs recommendations.
iv SAFETY iv PRÉCAUTIONS DE SÛRETÉ Pour votre propre protection lire et observer toutes les instructions et les précautions de sûreté specifiques qui parraissent dans ce manuel aussi bien que les précautions de sûreté générales suiv- antes: Sûreté Pour Soudage A LʼArc 1.
– 6 – v v Thank You for selecting a QUALITY product by Lincoln Electric. We want you to take pride in operating this Lincoln Electric Company product ••• as much pride as we have in bringing this product to you! Read this Operators Manual completely before attempting to use this equipment.
– 7 – T ABLE OF CONTENTS Page GENERAL DESCRIPTION ..................................................................................................8 RECOMMENDED PROCESSES & EQUIPMENT ...........................................................
– 8 – GENERAL DESCRIPTION The Idealarc ® 250 is a single phase constant current arc welding power source available in an AC/DC model only. Designed for stick welding, it may also be used for TIG welding when used with the K799 Hi- Freq unit.
– 9 – TECHNICAL SPECIFICA TIONS: IDEALARC AC/DC 250 Model AC/DC 250 AC/DC 250 Type K1053 K1054 AC Input Frequency 60 50 Output Rating NEMA CLASS II (60) IEC 974 AC DC AC DC Amperes 300 250 250 250 Volts 32 30 30 30 Duty Cycle 20 30 30 30 Current Range 35-300 40-250 35-250 40-250 Max.
– 10 – INST ALLA TION Safety Precautions • Connect the Idealarc 250 grounding terminal located under the reconnect panel (marked ) to a good electrical ground per the U.
– 11 – STACKING A. Make sure the first or bottom unit is setting on a level, well supported surface. B. The units must be stacked with their front flush, making sure the two holes in the base rails of the unit being stacked on top are over the two holes located on the top front corners of the unit being stacked on.
OPERA TION Safety Precautions Be sure the Idealarc 250 is properly installed, and that all accessories are properly hooked up before attempting operation. DUTY CYCLE This machine is rated at a 30% duty cycle at 250 amps or 50% duty cycle at 200 amp output.
MAINTENANCE Safety Precautions General Maintenance 1 . The fan motor has sealed ball bearings which requires no service. 2. In dusty locations dirt may clog the air channels causing the welder to run hot. Under these conditions carefully blow out the welder at regular intervals.
– 14 – TROUBLE A. Welder will not weld. B. Welder welds, but soon stops welding (DC only). CAUSE 1. Line switch not turned “On”. Supply line fuse blown. 2. Power circuit dead. 3. Broken power lead. 4. Wrong voltage. 5. Electrode or work lead loose or broken.
– 15 – TROUBLE C. Variable or sluggish welding. D. Welder wonʼt shut off. E. Polarity switch wonʼt turn. CAUSE 1. Poor work or electrode terminal connection. 2. Current too low. 3. Low line voltage. 4. Welding leads too small. 5. Old and badly frayed welding cables.
– 16 – NOTE: This diagram is for reference only. It may not be accurate for all machines covered by this manual. The specific diagram for a particular code is pasted inside the machine on one of the enclosure panels. If the diagram is illegible, write to the Service Department for a replacement.
– 17 – NOTE: This diagram is for reference only. It may not be accurate for all machines covered by this manual. The specific diagram for a particular code is pasted inside the machine on one of the enclosure panels. If the diagram is illegible, write to the Service Department for a replacement.
NOTES.
W ARNING AV I S O D E PRECAUCION A TTENTION W ARNUNG A TENÇÃO Spanish French German Portuguese Japanese Chinese Korean Arabic READ AND UNDERST AND THE MANUFACTURER’S INSTRUCTION FOR THIS EQUIPMENT AND THE CONSUMABLES TO BE USED AND FOLLOW YOUR EMPLOYER’S SAFETY PRACTICES.
W ARNING AV I S O D E PRECAUCION A TTENTION W ARNUNG A TENÇÃO Spanish French German Portuguese Japanese Chinese Korean Arabic LEIA E COMPREENDA AS INSTRUÇÕES DO F ABRICANTE P ARA ESTE EQUIP AMENTO E AS P ARTES DE USO, E SIGA AS PRÁTICAS DE SEGURANÇA DO EMPREGADOR.
• Sales and Service through Subsidiaries and Distributors Worldwide • Cleveland, Ohio 44117-1199 U.S.A. TEL: 216.481.8100 FAX: 216.486.1751 WEB SITE: www.
An important point after buying a device Lincoln Electric IM402-B (or even before the purchase) is to read its user manual. We should do this for several simple reasons:
If you have not bought Lincoln Electric IM402-B yet, this is a good time to familiarize yourself with the basic data on the product. First of all view first pages of the manual, you can find above. You should find there the most important technical data Lincoln Electric IM402-B - thus you can check whether the hardware meets your expectations. When delving into next pages of the user manual, Lincoln Electric IM402-B you will learn all the available features of the product, as well as information on its operation. The information that you get Lincoln Electric IM402-B will certainly help you make a decision on the purchase.
If you already are a holder of Lincoln Electric IM402-B, but have not read the manual yet, you should do it for the reasons described above. You will learn then if you properly used the available features, and whether you have not made any mistakes, which can shorten the lifetime Lincoln Electric IM402-B.
However, one of the most important roles played by the user manual is to help in solving problems with Lincoln Electric IM402-B. Almost always you will find there Troubleshooting, which are the most frequently occurring failures and malfunctions of the device Lincoln Electric IM402-B along with tips on how to solve them. Even if you fail to solve the problem, the manual will show you a further procedure – contact to the customer service center or the nearest service center