
PRO-CUT 60 (Single Phase)
IM399-D
PLASMA CUTTING SYSTEM
For use with all code number machines thru 10394

Safety Depends on You Lincoln arc welding and cutting equipment is designed and built with safety in mind. However, your overall safety can be increased by proper installation ... and thought- ful operation on your part. DO NOT INSTALL, OPERATE OR REPAIR THIS EQUIPMENT WITHOUT READING THIS MANUAL AND THE SAFETY PRECAUTIONS CONTAINED THROUGHOUT. And, most importantly, think before you act and be careful.
OPERATOR’S MANUAL

World's Leader in Welding and Cutting Products Premier Manufacturer of Industrial Motors
May, 1999

PROTECT YOURSELF AND OTHERS FROM POSSIBLE SERIOUS INJURY OR DEATH. KEEP CHILDREN AWAY. PACEMAKER WEARERS SHOULD CONSULT WITH THEIR DOCTOR BEFORE OPERATING. Read and understand the following safety highlights. For additional safety information it is strongly recommended that you pur- chase a copy of “Safety in Welding & Cutting - ANSI Standard Z49.1” from the American Welding Society, P.O. Box 351040, Miami, Florida 33135 or CSA Standard W117.2. BE SURE THAT ALL INSTALLATION, OPERATION, MAINTENANCE, AND REPAIR PROCEDURES ARE PERFORMED ONLY BY QUALIFIED INDIVIDUALS.
ELECTRIC SHOCK can kill. 1.a. The electrode and work (or ground) circuits are electrically “hot” when the power source is on. Do not touch these “hot” parts with your bare skin or wet clothing. Wear dry, hole-free gloves to insulate hands.
FUMES AND GASES can be dangerous. 3.a. Plasma cutting or gouging may produce fumes and gases hazardous to health. Avoid breathing these fumes and gases.When cutting or gouging, keep your head out of the fumes. Use enough ventila- tion and/or exhaust at the arc to keep fumes and gases away from the breathing zone. When cutting or gouging on lead or cadmium plated steel and other metals or coatings which produce highly toxic fumes keep expo- sure as low as possible and below Threshold Limit Values (TLV) using local exhaust or mechanical ventila- tion. In confined spaces or in some circumstances, out- doors, a respirator may be required. Additional precau- tions are also required when welding on galvanized steel. 3.b. Do not use plasma arc cutting or gouging in locations near chlorinated hydrocarbon vapors coming from degreasing, cleaning or spraying operations. The heat and rays of the arc can react with solvent vapors to form phosgene, a highly toxic gas, and other irritating products. 3.c. Gases used for plasma cutting and gouging can displace air and cause injury or death. Always use enough ventilation, especially in confined areas, to insure breathing air is safe. 3.d. Read and understand the manufacturer’s instructions for this equipment and the consumables to be used, including the material safety data sheet (MSDS) and follow your employ- er’s safety practices.
1.b. When the power source is operating voltages in excess of 250 volts are produced. This creates the potential for serious electrical shock - potentially even fatal.
1.c. Insulate yourself from work and ground using dry insulation. When cutting or gouging in damp locations, on metal frame- work such as floors, gratings or scaffolds and when in posi- tions such as sitting or lying, make certain the insulation is large enough to cover your full area of physical contact with work and ground.
1.d. Always be sure the work cable makes a good electrical con- nection with the metal being cut or gouged. The connection should be as close as possible to the area being cut or gouged.
1.e. Ground the work or metal to be cut or gouged to a good elec- trical (earth) ground.
1.f. Maintain the plasma torch, cable and work clamp in good, safe operating condition. Replace damaged insulation.
1.g. Never dip the torch in water for cooling or plasma cut or gouge in or under water.
CUTTING SPARKS can cause fire or explosion. 4.a..Remove fire hazards from the plasma cut- ting or gouging area. If this is not possible, cover them to prevent the cutting or gouging sparks from starting a fire. Remember that welding sparks and hot materials from plasma cutting or gouging can easily go through small cracks and openings to adjacent areas. Avoid cutting or gouging near hydraulic lines. Have a fire extinguisher readily available.
1.h. When working above floor level, protect yourself from a fall should you get a shock.
1.i. Operate the pilot arc with caution. The pilot arc is capable of burning the operator, others or even piercing safety clothing.
1.j. Also see Items 4c and 6.
4.b. Where compressed gases are to be used at the job site, spe- cial precautions should be used to prevent hazardous situa- tions. Refer to “Safety in Welding and Cutting” (ANSI Standard Z49.1) and the operating information for the equip- ment being used.
ARC RAYS can burn. 2.a. Use safety glasses and a shield with the prop- er filter and cover plates to protect your eyes from sparks and the rays of the arc when per- forming or observing plasma arc cutting or gouging. Glasses,headshield and filter lens should conform to ANSI Z87. I standards.
4.c. When not cutting or gouging, make certain no part of the elec- trode circuit is touching the work or ground. Accidental con- tact can cause overheating and create a fire hazard.
4.d. Do not cut or gouge tanks, drums or containers until the prop- er steps have been taken to insure that such procedures will not cause flammable or toxic vapors from substances inside. They can cause an explosion even though they have been “cleaned.” For information purchase “Recommended Safe Practices for the Preparation for Welding and Cutting of Containers and Piping That Have Held Hazardous Substances”, AWS F4.1 from the American Welding Society (see address above).
2.b. Use suitable clothing including gloves made from durable flame-resistant material to protect your skin and that of your helpers from the arc rays.
2.c. Protect other nearby personnel with suitable non-flammable screening and/or warn them not to watch the arc nor expose themselves to the arc rays or to hot spatter or metal.
4.e. Vent hollow castings or containers before heating, cutting or gouging. They may explode.
4.f. Do nor fuel engine driven equipment near area where plasma cutting or gouging.
Apr. ‘93

4.g. Sparks and spatter are thrown from the plasma arc. Wear safety glasses, ear protection and oil free protective garments such as leather gloves, heavy shirt, cuffless trousers, high shoes and a cap over your hair. Wear ear plugs when cutting or gouging out of position or in confined places. Always wear safety glasses with side shields when in a cutting or gouging area.
PLASMA ARC can injure.
7.a. Keep your body away from nozzle and plasma arc.
4.h. Connect the work cable to the work as close to the cutting or gouging area as practical. Work cables connected to the build- ing framework or other locations away from the cutting or gouging area increase the possibility of the current passing through lifting chains, crane cables or other alternate circuits. This can create fire hazards or overheat lifting chains or cables until they fail.
7.b. Operate the pilot arc with caution. The pilot arc is capable of burning the operator, others or even piercing safety clothing.
CYLINDER may explode if damaged. 5.a. Use only compressed gas cylinders contain- ing the correct gas for the process used and properly operating regulators designed for the gas and pressure used. All hoses, fittings, etc. should be suitable for the application and main- tained in good condition.
ELECTRIC AND MAGNETIC FIELDS may be dangerous 8.a. Electric current flowing through any con- ductor causes localized Electric and Magnetic Fields (EMF). Cutting or gouging current creates EMF fields around torch cables and cutting machines.
5.b. Always keep cylinders in an upright position securely chained to an undercarriage or fixed support.
8.b. EMF fields may interfere with some pacemakers, so opera- tors having a pacemaker should consult their physician before cutting or gouging.
5.d. Never allow any part of the electrode, torch or any other electrically “hot” parts to touch a cylinder.
8.c. Exposure to EMF fields during cutting or gouging may have other health effects which are now not known.
5.e. Keep your head and face away from the cylinder valve outlet when opening the cylinder valve.
8d. All operators should use the following procedures in order to minimize exposure to EMF fields from the cutting or gouging circuit:
5.f. Valve protection caps should always be in place and hand tight except when the cylinder is in use or connected for use.
8.d.1. Route the torch and work cables together - Secure them with tape when possible.
5.g. Read and follow the instructions on compressed gas cylin- ders, associated equipment, and CGA publication P-l, “Precautions for Safe Handling of Compressed Gases in Cylinders,”available from the Compressed Gas Association 1235 Jefferson Davis Highway, Arlington, VA 22202.
8.d.2. Never coil the torch cable around your body.
8.d.3. Do not place your body between the torch and work cables. If the torch cable is on your right side, the work cable should also be on your right side.
FOR ELECTRICALLY powered equipment. 6.a. Turn off input power using the disconnect switch at the fuse box before working on the equipment.
8.d.4. Connect the work cable to the workpiece as close as possible to the area being cut or gouged.
8.d.5. Do not work next to cutting power source.
6.b. Install equipment in accordance with the U.S. National Electrical Code, all local codes and the manufacturer’s rec- ommendations.
6.c. Ground the equipment in accordance with the U.S. National Electrical Code and the manufacturer’s recommendations.
Apr. ‘93


Please Examine Carton and Equipment For Damage Immediately When this equipment is shipped, title passes to the purchaser upon receipt by the carrier. Consequently, Claims for material damaged in shipment must be made by the purchaser against the transportation company at the time the shipment is received.
Please record your equipment identification information below for future reference. This information can be found on your machine nameplate.
Model Name & Number
Code & Serial Number
Date of Purchase
Whenever you request replacement parts for or information on this equipment always supply the information you have recorded above.
Read this Operators Manual completely before attempting to use this equipment. Save this manual and keep it handy for quick reference. Pay particular attention to the safety instructions we have provided for your protection. The level of seriousness to be applied to each is explained below:
This statement appears where the information must be followed exactly to avoid serious personal injury or loss of life.
This statement appears where the information must be followed to avoid minor personal injury or damage to this equipment.

Type 208/230/460/1/60 K1362-1 Handheld Torch with 25 ft. (7.6m) Cable K1362-2 Handheld Torch with 50 ft. (15.2m) Cable
230/460/1/60 K1361-1 Handheld Torch with 25 ft. (7.6m) Cable K1361-2 Handheld Torch with 50 ft. (15.2m) Cable
460/575/1/60 K1362-3 Handheld Torch with 25 ft. (7.6m) Cable K1362-4 Handheld Torch with 50 ft. (15.2m) Cable K1362-5 Robotic Torch with 50 ft. (15.2m) Cable K1362-6 Machine Torch with 50 ft. (15.2m) Cable K1362-7 Robotic Torch with 50 ft. (15.2m) Cable K1362-8 Machine Torch with 50 ft. (15.2m) Cable
K871-1 [25Ft.(7.6m)Cable] & K871-2 [50Ft.(15.2m)Cable] Magnum PCT 60 Air Cooled Torch
Input Frequency 60 Hz
Output Rating 60 Amps, 115 volts, 60% Duty Cycle 60 Amps, 115 volts, Maximum Output 45 Amps, 115 volts, 100% Duty Cycle
Pilot Current 22.5 amps Pilot Duty Cycle 25% (20 seconds out of 80 seconds) Current Range 25-60 Amps Maximum OCV 282 Volts Normal OCV 250 Volts Input Power
Standard Voltages 208/230/460/1/60 K1362-1, -2, -5, -6 Current 50/45/23 Amps Other Voltages 230/460/1/60 460/575/1/60 K1361-1, -2 K1362-3, -4, -7, -8 Current 45/23 Amps 23/18 Amps
Idle Current 4.5 amps @ 230V Maximum Idle Power 0.7 kW Maximum Power Factor @ Rated Load 0.65
w/25 ft. (7.6 m) Cable 322 lbs/146 kg w/50 ft. (15.2 m) Cable 329 lbs/149 kgDimensions, H x W x D Dimensions, H x W x D 34” x 19” x 22” (864mm x 483mm x 559mm) (includes lift bail and undercarriage)
Net Weight

PREHEAT TEMPERATURE FOR PLASMA CUTTING
The PRO-CUT® 60 is a constant current, single range, continuous control plasma cutting system. It provides excellent starting characteristics, cutting visibility and arc stability. The torch has a patented safety mecha- nism which insures that the consumables are in place before cutting or gouging. This is extremely important due to the high voltages involved.
Preheat temperature control is recommended for opti- mum mechanical properties, crack resistance and hardness control. This is particularly important on high alloy steels and heat treated aluminum. Job con- ditions, prevailing codes, alloy level, and other consid- erations may also require preheat temperature con- trol. The following minimum preheat temperature is recommended as a starting point. Higher tempera- tures may be used as required by the job conditions and/or prevailing codes. If cracking or excessive hardness occurs on the cut face, higher preheat tem- perature may be required. The recommended mini- mum preheat temperature for plate thickness up to 1/2 inch (12.7m) is 70 (°F) (21.1°C).
The PRO-CUT 60 comes standard with air regulator, coarse air filter, oil coalescing filter, and pressure gauge. The Pro-Cut 60 comes ready to use with the torch attached. Machines equipped with handheld torches are available with either 25 ft. (7.6m) or 50 ft. (15.2m) torch cable. The undercarriage is standard and is shipped assembled except for the handle. The machine is capable of cutting with nitrogen or air. Nitrogen is used to cut aluminum and other nonfer- rous metals.
The PRO-CUT is controlled by a microprocessor- based system. The machine performs rudimentary self troubleshooting when powered up, which aids in field servicing.
Because design, fabrication, erection and cutting vari- ables affect the results obtained in applying this type of information, the serviceability of a product or struc- ture is the responsibility of the user. Variation such as plate chemistry, plate surface condition (oil, scale), plate thickness, preheat, quench, gas type, gas flow rate and equipment may produce results different than those expected. Some adjustments to procedures may be necessary to compensate for unique individ- ual conditions. Test all procedures duplicating actual field conditions.

G Read the safety precautions at the beginning of this Operator's Manual before proceeding. G Only personnel that have read and under- stood this Operator’s Manual should install and operate this equipment. G Machine must be connected to system ground per any national, local or other applicable electrical codes. G The power switch is to be in the “OFF” position when connectiong power cord to input power.
Since the spark gap oscillator in the high frequency generator in the machine is similar to a radio transmit- ter, improper machine installation can result in radio and TV interference or problems with nearby electron- ic equipment.
Radiated interference can develop in the following four ways:
(1) Direct interference radiated from the machine.
(2) Direct interference radiated from the cutting
TURN THE INPUT POWER OFF USING THE DISCONNECT SWITCH AT THE FUSE BOX BEFORE ATTEMPTING TO CONNECT THE INPUT POWER LINES.
leads.
(3) Direct interference radiated from feedback into
the power lines.
(4) Interference from reradiation of “pickup” by
ungrounded metallic objects.
Keeping these contributing factors in mind, installing equipment per the following instructions should mini- mize problems.
(1) Keep the machine power supply lines as short as
possible.
(2) Keep the work and torch leads as short as possi-
ble and as close together as possible. Lengths should not exceed 50 ft. (15.2 m). Tape the leads together when practical.
Place the PRO-CUT where clean cooling air can freely circulate in through the front intake and out through the rear louvers. Dirt, dust or any foreign material that can be drawn into the machine should be kept at a minimum. Failure to observe these precau- tions can result in excessive operating temperatures and nuisance shutdown of the machine. Before plan- ning the installation, read the section entitled “High Frequency Interference Protection”.
(3) Be sure the torch and work cable rubber cover-
ings are free of cuts and cracks that allow high frequency leakage.
(4) Keep the torch in good repair and all connections
tight to reduce high frequency leakage.
(5) Keep all access panels and covers securely in
A source of clean, dry, compressed air or nitrogen must be supplied to the PRO-CUT. Oil in the air is a severe problem and must be avoided. The supply pressure must be between 70 and 120 psi (482 and 827 kPa). The flow rate is approximately 4.7 cfm (133 l/min.). Failure to observe these precautions could result in excessive operating temperatures or damage to the torch.
see CAUTION under “Input Connection”, sec- tion. The work terminal ground does not ground the machine frame.
(6) When the machine is enclosed in a metal build-
ing, several good earth driven electrical grounds around the periphery of the building are recommended.
Failure to observe these recommended installation procedures may cause radio or TV interference prob- lems and result in unsatisfactory cutting or gouging performance resulting from lost high frequency power.
place

Have a qualified electrician connect the input leads to L1 and L2 of the terminal block in accordance with any National Electrical Code, all local codes and the connection diagram located on the inside of the cover. Use ferrules provided (S19117-1) for #10 wire. No ferrule is required for #8 wire. Tighten screws to 16 in/lbs. (1.8 N.M.). See below.
Before starting the installation, check with the local power company if there is any question about whether your power supply is adequate for the voltage, amperes, phase, and frequency specified on the machine nameplate. Also be sure the planned instal- lation will meet the any National Electrical Code and local code requirements. This machine may be oper- ated from a single phase line or from one phase of a two or three phase line.
.50" (12.7mm)
Models that have multiple input voltages specified on the nameplate (e.g. 208/230/460) are shipped con- nected for the highest voltage. If the machine is to be operated on the lower voltage, it must be reconnected according to the instructions on the inside of the removable panel in the center of the rear panel. Machine supply line entry provision is next to the removable panel.
Place Ferrule (S19117-1) Over Wire as Shown Before Insertion into Machine Terminal Block.

(6.3 mm) NPT thread. Tighten the air fitting to prevent leakage but do not overtighten. The use of Teflon tape to seal the connection is recommended.
The frame of the machine must be grounded. A ground terminal marked with the symbol located at the left side of the input box is provided for this pur- pose. See the U.S. National Electrical Code for details on proper grounding methods. Follow other grounding instructions per the paragraph under “High Frequency Interference Protection”. On multiple voltage input machines, be sure the reconnect panel is connected per the following instructions for the voltage being supplied to the machine. See Figure 1 in the back of this manual.
Nitrogen from cylinders may be used with this machine. The cylinder of nitrogen gas must be equipped with a pressure regulator. No more than 120 psi (827 kPa) may be supplied to the regulator on the machine. Install a hose between the regulator on the gas cylinder and the gas inlet on the machine.
HIGH FREQUENCY SHOCK CAN CAUSE INJURY OR FALL.
The PRO-CUT comes factory equipped with a cutting torch.
Fuse the input circuit with the recommended super lag fuses. Choose an input and grounding wire size according to local codes or use the Input Connection table. “Delay type”(1) circuit breakers may be used in place of fuses. Using fuses or circuit breakers smaller than recommended may result in “nuisance” tripping from machine inrush currents even if not cutting or gouging at high currents.
Pictures of the torch along with the required replace- ment parts are shown in the parts lists in the back of this manual. The ends of the cable to be connected to the power source are unique. Follow the applicable instructions as given in Figure 2 in the back of this manual.
(1) Also called “inverse time” or “thermal/magnetic” circuit breakers; circuit breakers which have a delay in tripping action that decreases as the magni- tude of the current increases.
Attach the work clamp to the work cable (which extends from the front of the machine) as shown. Tighten nut and bolt securely.
AIR INPUT CONNECTIONS A source of clean compressed air or nitrogen must be supplied to the PRO-CUT. The supply pressure must be between 70 and 120 psi (482 and 827 kPa). The flow rate is approximately 4.7 cfm (133 l/min). Oil in the air is a very severe problem and must be avoided.
A. Turn on the line power.
B. Connect the air supply to the machine.
C. Turn the power switch on.
Remove the plastic thread protector from the regulator input port (located on the back of the machine). Use a suitable gas connection fitting to make the connection to the available air supply. The input port is a 1/4”
-The green “Power On” LED should begin to
glow.
Work cable · Work clamp

-The fan should start.
-If the “Safety” LED is glowing, push the “Safety
Reset” button. If there is no problem, the LED will go off. If there is a problem, refer to Step F and the Troubleshooting Guide.
D. Set the Purge/Run switch to Purge.
-The air should start.
-The “Air Pressure” LED should be lit.
The PRO-CUT has a smooth, continuous pilot arc. The pilot arc is only a means of transferring the arc to the workpiece for cutting. Repeated pilot arc starts, in rapid succession, is not recommended as these starts will generally reduce consumable life. Occasionally, the pilot arc may sputter or start intermittently. This is aggravated when the consumables are worn or the air pressure is too high. Always keep in mind that the pilot arc is designed to transfer the arc to the work- piece and not for numerous starts without cutting.
-Adjust the air regulator for 60 psi (413 kPa),
minimum while air is flowing.
E. Set the Purge/Run switch to Run.
-The air will continue to run for 20 seconds of
postflow. If the trigger is activated within this time period, the pilot arc will immediately start.
F. When ready to cut, place the work lead on the
piece to be cut, place the torch near the work, make certain all safety precautions have been taken and pull the trigger.
When properly used, plasma arc cutting or gouging is a very economical process.. Improper use will result in a very high operating cost.
-The air will flow for a preflow time of 2 seconds
and the pilot arc will start. (This is true unless the machine is in postflow, then the preflow time is skipped.)
-The “Output ON” LED will light.
-The pilot arc will run for 2.5 seconds and shut off
unless it is brought in contact with the work and the arc is transferred.
-When the arc is transferred, cutting begins.
Finish the cut to be made and release the trigger.
G. When the trigger is released, the arc will stop.
-The air will continue to run for 20 seconds of
postflow. If the trigger is activated within this time period, the pilot arc will immediately restart.
H. If the “Safety” LED lights at any time, check the following:
Output set below mid-range.
ELECTRIC SHOCK CAN KILL.

the output control is in the blue or red regions is in special tight corners. Always hold at least a 1/8” (3.2mm) standoff in those situations and use the S18817 shield cup.
Output set near mid-range.
Output set to maximum.
Output set above mid-range.

* Neither cutting performance nor machine reliabili- ty will be lessened by this condition.
ELECTRIC SHOCK CAN KILL. • Turn off machine at the disconnect switch on the front of the machine before tightening, cleaning or replacing consumables.

TROUBLESHOOTING PROCEDURES
ELECTRIC SHOCK CAN KILL. BEFORE PERFORMING ANY MAINTE- NANCE THAT REQUIRES OPENING THE CASE OF THE POWER SOURCE:
HOW TO USE THIS GUIDE: Carefully read through each applicable section listed on the following pages. Remember that most problems are caused by improp- er setup, such as switch settings, control settings, etc.
If you believe the set up is correct and the trouble still exists, first check for the obvious: input power, blown fuses, loose PC board connectors, broken wires and the like. The sections listed on the following pages are intended to help you find the less obvious sources of trouble.
ELECTRICAL SHOCK CAN KILL. • Turn off machine at the disconnect switch at the back of the machine before tightening, cleaning or replacing consumables.
Change consumables as required.

No LED’s light when the power switch is turned on. 1. Check the input power to be sure it is on.
TORCH WILL NOT LIGHT 1. Low air pressure results in a "no start" condition. The “MACHINE ON” LED is lit, but there is no "Air Pressure" LED must be lit when air is response when the trigger is pulled. flowing. Set the machine in purge mode. The air will turn on. Set the regulator on the back of the machine for 60 psi minimum. If the "AIR PRESSURE" LED does not light, raise the pressure slightly. If the inlet pressure is greater than 75 psi and the LED is not lit when air is flowing, there is a leak or the air filters in the regulator assembly are clogged.
The air begins to flow, the “OUTPUT ON” LED lights 1. Check the torch consumables to be sure they for a brief period, but no arc is established. are in tight, not dirty or greasy, and in good shape. Replace the consumables if necessary.

The arc starts but sputters badly. 1. Check the torch consumables to be sure they are tight, not dirty or greasy and in good shape. Replace if necessary.
The “THERMAL” LED is lit. The “FAULT” 1. The machine is overheated. Allow it to cool and LED is blinking. reset. The air intakes of the machine must not be blocked, or this will become a nuisance.
The “FAULT” LED is lit 1. The Fault circuit monitors the torch to see if it is shorted as well as internal machine failures.
4. Turn off the machine and turn it back on. If the “FAULT” LED will not stay off when you try to cut again and there is no problem with the torch, then something has failed in the machine and the machine should not be left on. 4a) Check electrode to pilot for short. 4b) Check air flow. 4c) Check the power board. During preflow, there should be no voltage between work and electrode and at end of preflow open circuit voltage should be present. Replace if bad. 5. Replace control PC board.
Alternating “AIR/FAULT” LED lights. 1. Replace control PC board.
The “OUTPUT ON” and “FAULT” LED’s 1. The pilot arc duty cycle has been exceeded. blink in alternating order. The machine will cool down and the lights will
quit blinking in about 20 seconds. The pilot arc is limited to 20 out of 80 seconds except in special circumstances such as cutting expanded metal. (See the section on expanded metal in the Operating Section.)
Airflow will not shut off. 1. Check harness 1J7 (C2) and 3J7 (H6).

The “SAFETY” LED is lit. 1. The machine will not operate. The machine senses that the nozzle is not in place, or the operator could be exposed to dangerous volt ages if the machine were allowed to operate.
6. Push the "SAFETY RESET" button, the LED should go out. If the LED does not go out, the thermal sensor in the torch head has actuated. Note that the thermal sensor exists in the hand held torches but not the machine or robotic torches. This sensor prevents the torch from melting, and should not trip in normal operation. Wait several minutes until the torch head is cool, and press the reset button. If the LED does not go out, check step 2 again before proceeding. Read the procedures section of this manual for instruction in proper cutting technique.
8. Check the continuity between pins 1 & 3 in the plastic amp connector on the torch assembly. This is the 4-pin connector that plugs into the power source. If the safety circuit is working properly, there will be continuity when the nozzle is in place and no continuity when the nozzle is removed. When the nozzle is in place, there must be continuity between pins 1 & 3 and the torch pilot lead. Replace the torch if the continu ity measurements are not as described, or else replace the control board.
No OCV when 2 and 4 are closed. 1. 190 VAC across H1 and H2.

LIGHTS CONDITION SUGGESTIONS
MACHINE ON Should always be on when machine is on. Normal
OUTPUT ON On when there is voltage potential at the Normal torch (cutting or pilot).
OUTPUT ON is blinking alternately with AIR PRESSURE when power is first There is a problem with the microprocessor, applied to machine. replace the Control PC board.
If OUTPUT ON is blinking alternately with FAULT, the pilot arc duty cycle is exceeded. Wait for machine lights to stop blinking.
AIR PRESSURE On whenever the air pressure is above 60 Normal conditions are purge, preflow, psi (413 kPa), there is an error condition postflow and cutting. mentioned above where air will turn on. The air will turn on for a brief time when power is first applied to machine.
THERMAL Should normally be off. If on, wait for machine to cool down.
FAULT Light on. At end of preflow, machine Check consumables, replace as needed. checks to see if the torch is shorted and if Check torch cable to see if it is punctured it can fire the transistors. or cut.
Light blinking. If cutting tried with air No air connected to machine, air pressure pressure less than 60 psi (413 kPa) while set too low, or air leak in system. air is flowing, the machine will wait for air pressure to become greater than 60 psi (413 kPa).
Light blinking alternately with OUTPUT Pilot arc duty cycle has been exceeded. ON. Wait for machine lights to stop blinking.
Light started blinking during cutting or If cutting or gouging with standoff more than gouging. There is an overcurrent condition 1/8” (3.2mm) at high range of machine and caused by a surge of current the machine nozzle is accidentally touched to work, shorten was not designed to handle. Release the stickout, or use Drag Cup. Check consumables trigger and resume cutting or gouging. to see if electrode melted to nozzle.
Light blinking with THERMAL light on. Wait for machine to cool.

LIGHTS CONDITION SUGGESTIONS
SAFETY It is possible that this light could turn on If machine can be reset, it is OK to continue when power is first applied to machine. operation.
The nozzle is not in place. Securely fasten nozzle in place.
While cutting or gouging if the voltage By pressing reset, the machine will be between the nozzle and the work is too functional. This occurs most often when the high, it will put the machine into SAFETY. consumables are wearing out. By removing the hafnium that builds up on the inside of the nozzle, it is possible to extend the life of the consumables.
If the cable is punctured or cut, it can trip By pressing reset, it will clear the SAFETY. the SAFETY When cutting is tried again, the machine will either go into FAULT or SAFETY; until that time, the machine will not indicate a malfunction condition.
The torch may be overheated. There is Wait for the torch to cool down, and a thermal sensor in thehand-held torch reset the safety circuit. Read the heads to protect it during abusive use. procedures section of this manual for It will not trip in normal use - even if it is instruction in proper cutting technique. abused heavily.

ELECTRIC SHOCK CAN KILL. BEFORE PERFORMING ANY MAINTE- NANCE THAT REQUIRES OPENING THE CASE OF THE POWER SOURCE:
Before replacing a PC board which is suspected of being defective, visually inspect the PC board in ques- tion for any damage to any of its components and conductors on the back of the board.
If there is no visible damage to the PC board, install a new one and see if this remedies the problem. If the problem is remedied, reinstall the old PC board to see if the problem still exists. If it does no longer exist with the old PC board:
If PC board is visibly damaged electrically (compo- nents burned, copper traces opened or damaged), before possibly subjecting the new PC board to the same cause of failure, check for possible shorts, opens or grounds caused by:
If PC board is visibly damaged mechanically (such as a part vibrated off or was crushed), inspect for cause, then remedy before installing a replacement PC board.
If there is damage to the PC board if replacing PC board corrects problem, return it to the local Lincoln Electric Field Service Shop.


the machine on one of the enclosure panels. If the diagram is illegible, write to the Service Department for a replacement. Give the equipment code number..
3 4 6 4 3 9 1 1 2 11 12
5 4 1 2 6 3 5 6 3 7 8 4 9



May96 May96


CUTTING TORCH CONNECTION DIAGRAM Do not operate with covers removed
C O N N E C T O R
S T R A I N R E L I E F C L A M P
C A B L E B O O T
T H E L I N C O L N E L E C T R I C C O . C L E V E L A N D , O H I O U . S . A .
May96


These are comprehensive single sources of information relative to Installation, Operation, Maintenance, Accessories, Theory of Operation, Replacement Parts, Electrical Diagrams and Extensive Troubleshooting.
ORDER FROM: Technical Service Group-Customer Service Dept. Lincoln Electric Company 22801 St. Clair Ave. Cleveland, Ohio 44117-1199
All orders must be pre-paid (US Funds Only): Please allow up to 4 weeks for delivery.
Qty. Titles Machine Codes Manual # Unit Price Total Price
Square Wave Tig 255 (Codes 10022-10134) SVM100-A $45.00 V300I (Codes 9826-10133) SVM101-A $45.00 SP100 (Codes 9284-10050) SVM102-A $45.00 Power Arc 4000 (Codes 10083) SVM103-A $45.00 Power Arc 4000 (Codes 10200-10244) SVM103-B $45.00 ProCut 60 Single Phase (Codes 9819-10118) SVM104-A $45.00 V300 PRO (Codes 9934-10131) SVM105-A $45.00 LN 7 GMA (Codes 9168-9931) SVM106-A $45.00 RANGER 8 (Codes 9972-10110) SVM107-A $45.00 DC600 (Codes 9773-9910) SVM108-A $45.00 POWER WAVE 350/500 (Codes 10104-10155) SVM109-A $65.00 RANGER 9 (Codes 9975-9976) SVM110-A $45.00 SP250 (Codes 9402-10002) SVM111-A $45.00 POWER WAVE 450 (Codes 10105-10195) SVM112-A $65.00 WELDAN POWER 125 (Codes 10158-10160) SVM113-A $45.00 LN25 (Codes 9218-10150) SVM114-A $45.00 SP255 (Codes 10164-10165) SVM115-A $45.00 Idealarc CV-300 (Codes 9456-10181) SVM116-A $45.00 Wire-matic 250 (Codes 9799-10004) SVM117-A $45.00 Square Wave TIG 355 (Codes 9951-9955) SVM118-A $45.00 Wire-matic 255 (Codes 10166,10167) SVM119-A $45.00 Ranger 10-LX (Codes 9975, 9976) SVM120-A $45.00
SHIP MANUALS TO:
Name:
Address:
Phone:
SD-267 3/96

New Lessons in Arc Welding
Lessons, simply written, cover manipulatory techniques; machine and electrode characteristics; related subjects, such as distortion; and supplemental information on arc welding applications, speeds and costs. Practice materials, exercises, questions and answers are suggested for each lesson.
With over 500,000 copies of previous editions published since 1933, the Procedure Handbook is considered by many to be the “Bible” of the arc welding industry.
This printing will go fast so don’t delay. Place your order now using the coupon below.
The hardbound book contains over 750 pages of welding information, techniques and procedures. Much of this material has never been included in any other book.
528 pages, well illustrated, 6” x 9” size, bound in simulated, gold embossed leather.
$5.00 postage paid U.S.A. Mainland
A must for all welders, supervisors, engineers and designers. Many welding instructors will want to use the book as a reference for all students by taking advantage of the low quantity discount prices which include shipping by 4th class parcel post. $15.00 postage paid U.S.A. Mainland
The Lincoln Electric Company operates the oldest and most respected Arc Welding School in the United States at its corporate headquarters in Cleveland, Ohio. Over 100,000 stu- dents have graduated. Tuition is low and the training is “hands on”
The book contains the latest information and application data on the American Welding Society Standard Welding Symbols. Detailed discussion tells how engineers and draftsmen use the “short-cut” language of symbols to pass on assembly and welding information to shop personnel.
For details write: Lincoln Welding School 22801 St. Clair Ave. Cleveland, Ohio 44117-1199.
Practical exercises and examples develop the reader’s ability to visualize mechanically drawn objects as they will appear in their assembled form.
and ask for bulletin ED-80 or call 216-383-2259 and ask for the Welding School Registrar.
187 pages with more than 100 illustrations. Size 8-1/2” x 11” Durable, cloth-covered board binding.
BASIC COURSE $700.00 5 weeks of fundamentals
$4.50 postage paid U.S.A. Mainland
There is a 10% discount on all orders of $50.00 or more for shipment at one time to one location. Orders of $50 or less before discount or orders outside of North America must be prepaid with charge, check or money order in U.S. Funds Only. Prices include shipment by 4thClass Book Rate for U.S.A. Mainland Only. Please allow up to 4 weeks for delivery. UPS Shipping for North America Only. All prepaid orders that request UPS shipment please add:
$5.00 For order value up to $49.99 $10.00 For order value between $50.00 & $99.99 $15.00 For order value between $100.00 & $149.00
For North America invoiced orders over $50.00 & credit card orders, if UPS is requested, it will be invoiced or charged to you at cost. Outside U.S.A. Mainland order must be prepaid in U.S. Funds. Please add $2.00 per book for surface mail or $15.00 per book for air parcel post shipment. METHOD OF PAYMENT: (Sorry, No C.O.D. Orders)
Ë Please Invoice (only if order is over $50.00)
Ë Check or Money Order Enclosed, U.S. Funds only
Ë Credit Card - Ë Ë Telephone:
VISA ® MasterCard MasterCard
Signature as it appears on Charge Card: Account No. |_|_|_|_|_|_|_|_|_|_|_|_|_|_|_|_|_|_|_|_|_| Exp Date |_|_| |_|_| Month Year
USE THIS FORM TO ORDER: Order from: BOOK DIVISION, The Lincoln Electric Company, 22801 St. Clair Avenue, Cleveland, Ohio 44117-1199 BOOKS OR FREE INFORMATIVE CATALOGS Telephone: 216-383-2211 or, for fastest service, FAX this completed form to: 216-361-5901.
Lincoln Welding School Ë Titles: Price Code Quantity Cost (ED-80) New Lessons in Arc Welding $5.00 L Seminar Information Ë Procedure Handbook “Twelfth Edition” $15.00 PH (ED-45) How to Read Shop Drawings $4.50 H Educational Video Information Ë Incentive Management $5.00 IM (ED-93) A New Approach to Industrial Economics $5.00 NA James F. Lincoln Arc Welding The American Century of John C. Lincoln $5.00 AC Foundation Book Information Ë Welding Preheat Calculator $3.00 WC-8 (JFLF-515) Pipe Welding Charts $4.50 ED-89
SUB TOTAL Additional Shipping Costs if any
®

G Do not touch electrically live parts or
G Keep flammable materials away.
G Wear eye, ear and body protection.
electrode with skin or wet clothing. G Insulate yourself from work and
ground.
G No toque las partes o los electrodos
G Mantenga el material combustible
G Protéjase los ojos, los oídos y el
bajo carga con la piel o ropa moja- da. G Aislese del trabajo y de la tierra.
fuera del área de trabajo.
cuerpo.
G Ne laissez ni la peau ni des vête-
G Gardez à l’écart de tout matériel
G Protégez vos yeux, vos oreilles et
ments mouillés entrer en contact avec des pièces sous tension. G Isolez-vous du travail et de la terre.
inflammable.
votre corps.
G Berühren Sie keine stromführenden
G Entfernen Sie brennbarres Material!
G Tragen Sie Augen-, Ohren- und Kör-
Teile oder Elektroden mit Ihrem Körper oder feuchter Kleidung! G Isolieren Sie sich von den
Elektroden und dem Erdboden!
G Não toque partes elétricas e elec-
G Mantenha inflamáveis bem guarda-
G Use proteção para a vista, ouvido e
trodos com a pele ou roupa molha- da. G Isole-se da peça e terra.
dos.
corpo.



READ AND UNDERSTAND THE MANUFACTURER’S INSTRUCTION FOR THIS EQUIPMENT AND THE CONSUMABLES TO BE USED AND FOLLOW YOUR EMPLOYER’S SAFETY PRACTICES.
SE RECOMIENDA LEER Y ENTENDER LAS INSTRUCCIONES DEL FABRICANTE PARA EL USO DE ESTE EQUIPO Y LOS CONSUMIBLES QUE VA A UTILIZAR, SIGA LAS MEDIDAS DE SEGURIDAD DE SU SUPERVISOR.
LISEZ ET COMPRENEZ LES INSTRUCTIONS DU FABRICANT EN CE QUI REGARDE CET EQUIPMENT ET LES PRODUITS A ETRE EMPLOYES ET SUIVEZ LES PROCEDURES DE SECURITE DE VOTRE EMPLOYEUR.
LESEN SIE UND BEFOLGEN SIE DIE BETRIEBSANLEITUNG DER ANLAGE UND DEN ELEKTRODENEINSATZ DES HER- STELLERS. DIE UNFALLVERHÜTUNGSVORSCHRIFTEN DES ARBEITGEBERS SIND EBENFALLS ZU BEACHTEN.

G Keep your head out of fumes. G Use ventilation or exhaust to
G Turn power off before servicing.
G Do not operate with panel open or
guards off.
remove fumes from breathing zone.
G Los humos fuera de la zona de res-
G Desconectar el cable de ali-
G No operar con panel abierto o
piración. G Mantenga la cabeza fuera de los
mentación de poder de la máquina antes de iniciar cualquier servicio.
guardas quitadas.
humos. Utilice ventilación o aspiración para gases.
G Gardez la tête à l’écart des fumées. G Utilisez un ventilateur ou un aspira-
G Débranchez le courant avant l’entre-
G N’opérez pas avec les panneaux
tien.
ouverts ou avec les dispositifs de protection enlevés.
teur pour ôter les fumées des zones de travail.
G Vermeiden Sie das Einatmen von
G Strom vor Wartungsarbeiten
G Anlage nie ohne Schutzgehäuse
Schweibrauch! G Sorgen Sie für gute Be- und
abschalten! (Netzstrom völlig öff- nen; Maschine anhalten!)
oder Innenschutzverkleidung in Betrieb setzen!
SEE IMWS 1
G Mantenha seu rosto da fumaça. G Use ventilação e exhaustão para
G Não opere com as tampas removidas. G Desligue a corrente antes de fazer
G Mantenha-se afastado das partes
moventes. G Não opere com os paineis abertos
remover fumo da zona respiratória.
serviço. G Não toque as partes elétricas nuas.
ou guardas removidas.



LEIA E COMPREENDA AS INSTRUÇÕES DO FABRICANTE PARA ESTE EQUIPAMENTO E AS PARTES DE USO, E SIGA AS PRÁTICAS DE SEGURANÇA DO EMPREGADOR.

Common problems, likely causes, and what to do.
| Problem | Possible cause | Remedy | |
|---|---|---|---|
| – 8 – | p.8 | ||
| • Check the assembly of the torch consumables. If they are not properly in place then the machine will not start. | p.12 | ||
| – 12 – | p.12 | ||
| – 14 – | p.14 | ||
| No LED’s light when the power switch is turned on. | 1. Check the input power to be sure it is on. 2. Check the power line fuses and machine connection. 3. Replace line switch. | p.16 | |
| TORCH WILL NOT LIGHT The “MACHINE ON” LED is lit, but there is no response when the trigger is pulled. | 1. Low air pressure results in a "no start" condition. "Air Pressure" LED must be lit when air is flowing. Set the machine in purge mode. The air will turn on. Set the regulator on the back of the machine for 60 psi minimum. If the "AIR PRESSURE" LED does not light, raise the pressure slightly. If the inlet pressure is greater than 75 psi and the LED is not lit when air is flowing, there is a leak or the air filters in the regulator assembly are clogged. 2. Check the "SAFETY" LED. If it is lit, check the torch consumables and press the "SAFETY RESET" button. 3. Check the air supply to the machine. If the air does not flow, the machine will not start. 4. Check the operation of the air solenoid by switching the machine to "PURGE". The air should begin to flow and if the pressure is suffi cient, the "AIR PRESSURE" LED will light. Return to "RUN" mode. If air does not flow, check the solenoid by applying 115 VAC to its input leads. If it is bad, replace the solenoid, or else replace the control board. | p.16 | |
| The air begins to flow, the “OUTPUT ON” LED lights for a brief period, but no arc is established. | 1. Check the torch consumables to be sure they are in tight, not dirty or greasy, and in good shape. Replace the consumables if necessary. 2. Check that CR2 engages. 3. Check for high frequency at the spark gap. 4. Check the high frequency spark gap located inside the right panel of the machine. It should be set at .060” (1.52mm) DISCONNECT ALL POWER BEFORE ADJUSTING THE HIGH FREQUENCY CIRCUIT. 5. Blow off the components in the upper compart- ment with compressed air. 6. Check pilot to 391 for 2 ohm resistance. 7. Check 2 ohm 300 watt resistor. 8. Replace Control PC Board. | p.16 | |
| The arc starts but sputters badly. | 1. Check the torch consumables to be sure they are tight, not dirty or greasy and in good shape. Replace if necessary. 2. Check air supply for oil or a great deal of water. If there is oil or a great deal of water, the air must be filtered or the machine switched to nitrogen or bottled air. 3. Check the air pressure. The pressure must be 60 psi (413 kPa) minimum while air is flowing. The "Air Pressure" LED must be lit. | p.17 | |
| The “THERMAL” LED is lit. The “FAULT” LED is blinking. | 1. The machine is overheated. Allow it to cool and reset. The air intakes of the machine must not be blocked, or this will become a nuisance. | p.17 | |
| The “FAULT” LED is lit | 1. The Fault circuit monitors the torch to see if it is shorted as well as internal machine failures. 2. Check the torch consumables to see if they are melted together or are simply touching each other. Tighten, clean or replace. See “Suggestion for Extra Utility from the PRO-CUT System”. 3. Check the torch cab le to see if it is cut or punctured. Replace. 4. Turn off the machine and turn it back on. If the “FAULT” LED will not stay off when you try to cut again and there is no problem with the torch, then something has failed in the machine and the machine should not be left on. 4a) Check electrode to pilot for short. 4b) Check air flow. 4c) Check the power board. During preflow, there should be no voltage between work and electrode and at end of preflow open circuit voltage should be present. Replace if bad. 5. Replace control PC board. | p.17 | |
| Alternating “AIR/FAULT” LED lights. | 1. Replace control PC board. 1. The pilot arc duty cycle has been exceeded. The machine will cool down and the lights will quit blinking in about 20 seconds. The pilot arc is limited to 20 out of 80 seconds except in special circumstances such as cutting expanded metal. (See the section on expanded metal in the Operating Section.) 1. Check harness 1J7 (C2) and 3J7 (H6). | p.17 | |
| The “OUTPUT ON” and “FAULT” LED’s blink in alternating order. | p.17 | ||
| Airflow will not shut off. | p.17 | ||
| The “SAFETY” LED is lit. | 1. The machine will not operate. The machine senses that the nozzle is not in place, or the operator could be exposed to dangerous volt ages if the machine were allowed to operate. 2. Check the nozzle to be sure it is tightly in place. 3. Check the torch consumables to see if they are melted together or are simply touching each other. Tighten, clean or replace. See “Suggestion for Extra Utility from the Pro-Cut System”. 4. Check the torch cable to see if it is cut or punc- tured. Replace. 5. Check to see that the torch is hooked to the machine properly. 6. Push the "SAFETY RESET" button, the LED should go out. If the LED does not go out, the thermal sensor in the torch head has actuated. Note that the thermal sensor exists in the hand held torches but not the machine or robotic torches. This sensor prevents the torch from melting, and should not trip in normal operation. Wait several minutes until the torch head is cool, and press the reset button. If the LED does not go out, check step 2 again before proceeding. Read the procedures section of this manual for instruction in proper cutting technique. 7. This circuit rarely trips on power up or because of noise. If the circuit can be reset, it is Ok to continue operation. 8. Check the continuity between pins 1 & 3 in the plastic amp connector on the torch assembly. This is the 4-pin connector that plugs into the power source. If the safety circuit is working properly, there will be continuity when the nozzle is in place and no continuity when the nozzle is removed. When the nozzle is in place, there must be continuity between pins 1 & 3 and the torch pilot lead. Replace the torch if the continu ity measurements are not as described, or else replace the control board. | p.18 | |
| No OCV when 2 and 4 are closed. | 1. 190 VAC across H1 and H2. 2. 250V SCR PC board positive/negative 3. Check across 31/32 for 110 VAC. 4. Replace Control PC board. | p.18 |
Owners and our team usually reply within a day — and your question helps the next person too.
Be the first to ask — other owners or our team will answer.