Operating and installation instructions Combined fridge-freezer for integrated use, door-on-door 070711 7084284 - 03 IC/ICN/SICN/ICP ... 6.
Contents 1 Appliance at a glance ............................................ 2 1.1 Description of appliance and equipment .................. 2 1.2 Range of appliance use ............................................ 2 1.3 Conformity ..................
Note u Compliance with the ambient temperatures indicated is required, otherwise the cooling performance is reduced. Climate rating for ambient temperatures of SN 10 °C to 32 °C N 16 °C to 32 °C ST 16 °C to 38 °C T 16 °C to 43 °C 1.3 Conformity The refrigerant circuit has been tested for leaks.
3 Controls and displays 3.1 Operating and control elements Fig. 2 (1) Alarm button (8) Child-proofing symbol (2) SuperFrost button (9) Down setting button, refrigerator compartment (3) On/Off button, .
u Unscrew the red transport lock. Close the vacated retaining hole using the stopper (60). u Dispose of packaging material (see 4.6) . Note u Clean the appliance (see 6.3) . If the appliance is installed in a very damp environment, condensate may form on the outside of the appliance.
4.4 Water connection* WARNING Danger of electric shock! u Disconnect the appliance by unplugging it before you connect it to the water line. u Shut off the water supply before you connect the water feed lines of the IceMaker. u The connection to the drinking water system may be carried out only by a qualified gas fitter and plumber.
Fig. 7 4.5.1 Installing the appliance Fig. 8 u Detach the connecting cable from the rear of the appli- ance. Remove the cable holder otherwise there will be vibratory noise. u Lay the connecting cable with the help of string in such a way that the appliance can be easily connected following installation.
u Fit the equaliser trim Fig. 10 (20) concentri- cally onto the appliance: Slide it into the recess and engage it in the keyholes. Fig. 10 u Screw all the mounting brackets Fig. 11 (34) to the pre-drilled holes in the appliance door using hexagon screws Fig.
The fitting aids Fig. 20 (30) are required for both doors. Therefore fit the unit doors one after the other . u Check 8 mm-presetting. (Distance between appliance door and lower edge of crosspiece) u Slide up the assembly aids Fig. 20 (30) to the height of the unit door.
u Put on and engage the covers Fig. 8 (5,6,7) . For appliances without soft stop mechanism adjust door stop cushioning: The door stop cushioning can be adjusted if necessary using the accompanying Allen key:* u For stronger spring force: turn clockwise.
w The display indicates c . w The button SuperFrost flashes. u Briefly press the SuperFrost button Fig. 2 (2) to confirm. u To switch on: Using the Up setting button, freezer compartment Fig. 2 (5) or Down setting button, freezer compartment Fig. 2 (4) , select c1 .
- at high room temperature (above33 °C ) - at high humidity The forced-air cooling uses slightly more energy. To save energy, the fan switches off automatically when the door is open. Switching on the fan* u Briefly press the fan button Fig. 2 (13) .
5.6.3 Setting the temperature in the freezer compartment The appliance is pre-set for normal operation. The temperature can be set between -16 °C and -26 °C / Australia model -14 °C and -26 °C, the recommended tempera- ture is -18 °C. u To set the temperature higher: press Up button, freezer compartment Fig.
Using cold storage accumulators* u Freeze and store the cold storage accumu- lators in the ceiling of the freezer compart- ment (appliances without No-Frost module).
u Pay attention that the defrost water does not run into the kitchen unit. u If necessary, pick up defrost water several times, using a sponge or cloth. u Clean the appliance (see 6.3) and rub dry. 6.2 Defrosting with NoFrost* The NoFrost system automatically defrosts the appliance.
u Clip the back end of the cover in and clip the sides into place. 6.6 Customer service First check whether you can correct the fault yourself by refer- ence to the list (see Malfunction). If this is not the case, please contact the customer service whose address is given in the enclosed customer service list.
→ Insufficient ventilation. u Clear ventilation grilles. → The ambient temperature is too high. u Solution: (see 1.2) . → The appliance was opened too frequently or for too long. u Wait until the appliance reaches the required temperature itself.
Disposing of the appliance 18.
An important point after buying a device Liebherr 7084284-03 (or even before the purchase) is to read its user manual. We should do this for several simple reasons:
If you have not bought Liebherr 7084284-03 yet, this is a good time to familiarize yourself with the basic data on the product. First of all view first pages of the manual, you can find above. You should find there the most important technical data Liebherr 7084284-03 - thus you can check whether the hardware meets your expectations. When delving into next pages of the user manual, Liebherr 7084284-03 you will learn all the available features of the product, as well as information on its operation. The information that you get Liebherr 7084284-03 will certainly help you make a decision on the purchase.
If you already are a holder of Liebherr 7084284-03, but have not read the manual yet, you should do it for the reasons described above. You will learn then if you properly used the available features, and whether you have not made any mistakes, which can shorten the lifetime Liebherr 7084284-03.
However, one of the most important roles played by the user manual is to help in solving problems with Liebherr 7084284-03. Almost always you will find there Troubleshooting, which are the most frequently occurring failures and malfunctions of the device Liebherr 7084284-03 along with tips on how to solve them. Even if you fail to solve the problem, the manual will show you a further procedure – contact to the customer service center or the nearest service center