Installation Supplement and Administrator Guide
Lexmark and Lexmark with diamond design are trademarks of Lexmark International, Inc., registered in the United States and/or other countries. All other trademarks are the property of their respective owners.
© 2011 Lexmark International, Inc. All rights reserved. 740 West New Circle Road Lexington, Kentucky 40550
3065326-001

Edition notice November 2011 The following paragraph does not apply to any country where such provisions are inconsistent with local law: LEXMARK INTERNATIONAL, INC., PROVIDES THIS PUBLICATION “AS IS” WITHOUT WARRANTY OF ANY KIND, EITHER EXPRESS OR IMPLIED, INCLUDING, BUT NOT LIMITED TO, THE IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. Some states do not allow disclaimer of express or implied warranties in certain transactions; therefore, this statement may not apply to you. This publication could include technical inaccuracies or typographical errors. Changes are periodically made to the information herein; these changes will be incorporated in later editions. Improvements or changes in the products or the programs described may be made at any time. For Lexmark technical support, visit support.lexmark.com. For information on supplies and downloads, visit www.lexmark.com. If you don't have access to the Internet, you can contact Lexmark by mail: Lexmark International, Inc. Bldg 004-2/CSC 740 New Circle Road NW Lexington, KY 40550 References in this publication to products, programs, or services do not imply that the manufacturer intends to make these available in all countries in which it operates. Any reference to a product, program, or service is not intended to state or imply that only that product, program, or service may be used. Any functionally equivalent product, program, or service that does not infringe any existing intellectual property right may be used instead. Evaluation and verification of operation in conjunction with other products, programs, or services, except those expressly designated by the manufacturer, are the user’s responsibility. © 2011 Lexmark International, Inc. All rights reserved.
UNITED STATES GOVERNMENT RIGHTS This software and any accompanying documentation provided under this agreement are commercial computer software and documentation developed exclusively at private expense.
Trademarks Lexmark, Lexmark with diamond design, and MarkVision are trademarks of Lexmark International, Inc., registered in the United States and/or other countries. All other trademarks are the property of their respective owners.


Overview
This guide describes how to configure a supported LexmarkTM multifunction printer (MFP) to reach Common Criteria Evaluation Assurance Level 2 (EAL 2). It is critical that you carefully follow the instructions in this guide, as failure to do so may result in a device that does not meet the requirements of the evaluation.
This guide is intended for use by Lexmark service providers, and network administrators responsible for the management of security appliances and software in their network environment. A working knowledge of Lexmark multifunction printers is required for effective use of this guide.
Some settings can be configured using either the Embedded Web Server (EWS), or the device touch screen. Where applicable, instructions for both methods are included.
For information about physically setting up the MFP or using device features, see the User Guide that came with your MFP. For information about using the MFP touch screen, see“Appendix A: Using the touch screen” on page 44.
This guide describes how to implement an evaluated configuration on the following models:

The instructions provided in this guide are based on the following assumptions and objectives:
Before beginning configuration tasks, you must:
1 Inspect the MFP to verify that only one network interface is installed. There should be no optional network, parallel, or serial interfaces.
2 Turn the MFP on using the power switch.
> Reports > Menu Settings Page. Several pages of device information will print.
4 In the Installed Features section, verify that no Download Emulator (DLE) option cards have been installed.
5 If you find additional interfaces, or if a DLE card has been installed, then contact your Lexmark representative before proceeding.
6 To verify the firmware version, under Device Information, locate Base =, and Network =.
7 Contact your Lexmark representative to verify that the Base and Network values are correct and up‑to‑date.

Once a lock is attached, the metal plate and system board cannot be removed, and the security jumper cannot be accessed without causing visible damage to the device.
1 Verify that the MFP case is closed.
2 Locate the security slot, and then attach a lock. It is the same type of security slot found on most laptop computers and can normally be found on the back of the MFP near an outside edge.
The following illustrations show the most common security slot locations:

Hard disk encryption helps prevent the loss of sensitive data in the event your MFP—or its hard disk—is stolen.
1 Turn off the MFP using the power switch.
2 Simultaneously press and hold the 2 and 6 keys on the numeric keypad while turning the device back on. It takes approximately a minute to boot into the Configuration menu.
Once the MFP is ready, the touch screen displays a list of functions instead of standard home screen icons such as Copy and Fax.

3 Verify that the MFP is in Configuration mode by locating the Exit Config Menu icon in the lower right corner of the touch screen.
4 Scroll through the configuration menus to locate the Disk Encryption menu selection.
5 Touch Disk Encryption > Enable.
6 The following message appears: Contents will be lost. Continue? • Touch Yes to proceed with disk wiping and encryption. A status bar will indicate the progress of the encryption task. Disk encryption can take several hours to complete. After the disk has been encrypted, the MFP will return to the Enable/Disable screen. Warning: Do not turn off the device during the encryption process. Doing so may result in loss of data.
7 Touch Back, and then touch Exit Config Menu.
The MFP will undergo a power‑on reset, and then return to normal operating mode.
Disabling the USB buffer disables the USB host port on the back of the device.
> Network/Ports > Standard USB.
2 Set USB Buffer to Disabled.
3 Touch Submit.

You can achieve an evaluated configuration on a non-networked (standalone) device in just a few steps. For this configuration, all tasks are performed at the device, using the touch screen.
This checklist outlines the steps required to implement an evaluated configuration on a standalone device. For information about additional configuration options, see “Administering the device” on page 15.
After completing the pre‑configuration tasks found in “Before configuring the device (required)” on page 6, continue with this section to configure the settings needed to achieve the evaluated configuration for a standalone device:
1 Set up disk wiping.
2 Create user accounts.
3 Create security templates.
4 Restrict access to device functions.
5 Disable home screen icons.
Disk wiping is used to remove residual confidential material from the device. Disk wiping uses random data patterns to securely overwrite files stored on the hard drive that have been marked for deletion. Multi‑pass wiping is compliant with the DoD 5220.22‑M standard for securely erasing data from a hard disk.
> Security > Disk Wiping.
2 Set Wiping Mode to Auto.
3 Set Automatic Method to Multi‑pass.
4 Touch Submit.
> Security > Edit Security Setups > Edit Backup Password > Password.
2 Type the password you want to use, and then touch Done.

3 Retype the password, and then touch Done to save the new password and return to the Edit Backup Password screen.
4 Set Use Backup Password to On.
5 Touch Submit.
Creating internal (device) accounts for use with the evaluated configuration involves not only assigning a user ID and password to each user, but also segmenting users into groups. When configuring security templates, you will select one or more of these groups, and then you will apply a security template to each device function to control access to that function. The MFP supports a maximum of 250 user accounts and 32 user groups.
> Security > Edit Security Setups > Edit Building Blocks > Internal Accounts > General Settings > Groups for Internal Accounts.
2 On the Groups for Internal Accounts screen, touch Add Entry.
3 For the Name, type Administrator_Only.
4 Touch Done to save this group and return to the Groups for Internal Accounts screen.
5 Touch Add Entry.
6 For the Name, type Authenticated_Users.
7 Touch Done to save this group.

> Security > Edit Security Setups > Edit Building Blocks > Internal Accounts > General Settings.
2 On the General Settings screen, set Required User Credentials to User ID and password, and then touch Submit. The MFP will return to the Internal Accounts screen.
3 Select Manage Internal Accounts > Add Entry.
4 Type the user's account name (example: “Jack Smith”), and then touch Done.
5 Type a user ID for the account (example: “jsmith”), and then touch Done.
7 Retype the password, and then touch Done.
8 Type the user's e-mail address (example: “jsmith@company.com”), and then touch Done.
10 After selecting the appropriate group or groups, touch Done to save the account and return to the Manage Internal Accounts screen, where the user should now be listed.
11 Repeat the steps as needed to add more users.
A security template is assigned to each device function to control which users are permitted to access that function. At a minimum, you must create two security templates: one for "Administrator_Only" and one for "Authenticated_Users." If there is a need to grant access to some administrative functions while restricting others, then you can create additional security templates, such as “Administrator_Reports” or “Administrator_Security.” Each template will be populated with groups containing users authorized to access the functions protected by that template.
> Security > Edit Security Setups > Edit Security Templates.
2 Touch Add Entry.

3 Type a unique name to identify the template. Use a descriptive name, such as ”Administrator_Only” or “Authenticated_Users,” and then touch Done.
4 On the Authentication Setup screen, select the internal accounts building block, and then touch Done.
5 On the Authorization Setup screen, select the internal accounts building block, and then touch Done.
6 Select one or more groups to be included in the template, and then touch Done to save your changes and return to the Edit Security Templates screen.
Access to device functions can be restricted by applying security templates to individual functions. For a list of access controls and what they do, see “Access controls” on page 47.
> Security > Edit Security Setups > Edit Access Controls.
2 Select the appropriate level of protection for each function, as specified in the following table. It may be necessary to scroll through several screens to set all access controls.
3 After assigning an appropriate security template to all functions, touch Submit.
Levels of protection include:


Option Card Configuration at the Device Administrator access only

Access control Level of protection
Held Jobs Access Disabled
Use Profiles Authenticated users only
Change Language from Home Screen Authenticated users only
Cancel Jobs at the Device Administrator access only
PictBridge Printing Not applicable—USB port disabled
Solution 1 Authenticated users only
Solutions 2‑10 Administrator access only
New Solutions Administrator access only
The final step is to remove unneeded icons from the MFP home screen.
> Settings > General Settings.
2 Touch Home screen customization.
3 Set FTP, FTP shortcuts, and USB Drive to Do not display.
4 Touch Submit.

This chapter describes how to configure additional settings and functions that may be available on your device.
Many settings can be configured using either the Embedded Web Server (EWS) or the touch screen.
1 Type the device IP address or host name in the address field of your Web browser using the secure version of the page (with the address beginning “https://”).
2 Use the navigation menu on the left to access configuration and report menus.
> Reports > Network Setup Page. After the network setup page prints, the MFP will return to the home screen.
After attaching the MFP to a network, you will need to configure additional settings. This section covers the basic settings required for a network-connected device.
Certificates are needed for domain controller verification and for SSL support in LDAP. Each certificate must be in a separate PEM (.cer) file.
The values entered here will be present in all new certificates generated in the Certificate Management task.
1 From the Embedded Web Server, click Settings > Security > Certificate Management.
2 Click Set Certificate Defaults.
3 Enter values in the appropriate fields: • Common Name—Type a name for the device.

4 Click Submit.
1 From the Embedded Web Server, click Settings > Security > Certificate Management.
2 Click Device Certificate Management > New.
4 Click Generate New Certificate.
1 From the Embedded Web Server, click Settings > Security > Certificate Management.
2 Click Device Certificate Management.
3 Select a certificate from the list.
The details of the certificate are displayed in the Device Certificate Management window.

The contents of the file should be in the following format:
A Certificate Authority (CA) certificate is required if you will be using the PKI Authentication application.
1 From the Embedded Web Server, click Settings > Security > Certificate Management > Certificate Authority Management.
2 Click New.
3 Click Browse to locate the Certificate Authority Source file, and then click Submit.
4 Reboot the MFP by turning it off and back on using the power switch.
IPSec encrypts IP packets as they are transmitted over the network between devices. It does not handle authentication or restrict access.
1 From the Embedded Web Server, click Settings > Security > IPSec.
2 Select the IPSec Enable check box, and then click Submit. Your browser will return to the Security page.
3 Click IPSec.
4 In the Settings section, click Encryption, and then select 3DES from the Proposed Encryption Method drop‑down menu.
5 In the Settings section, click Certificate Validation, and then select the Validate Peer Certificate check box.
6 In the Connections section, click either Pre‑Shared Key Authenticated Connections or Certificate Authenticated Connections, and then click one of the numbered Host fields.
7 Type the IP address of the client device you want to connect to the MFP. If you are using Pre‑Shared Key (PSK) Authentication, then also type the key.
8 Configure IPSec as needed on client devices that will connect to the MFP.
9 Click Submit.

IP is the only network protocol permitted under this evaluation. The AppleTalk protocol must be disabled.
1 From the Embedded Web Server, click Settings > Network/Ports > AppleTalk.
2 Verify that the Activate check box is cleared, and then click Submit.
> Network/Ports > Standard Network > STD NET SETUP.
2 From the Std Network Setup screen, touch AppleTalk > Activate.
3 Set Activate to No.
4 Touch Submit. The MFP will return to the AppleTalk screen. From there you can touch Back to return to the Std Network Setup screen or the home icon to return to the home screen.
Disabling virtual ports helps prevent intruders from accessing the MFP using a network connection. For information about accessing the EWS, see “Using the Embedded Web Server” on page 15.
1 From the Embedded Web Server, click Settings > Security > TCP/IP Port Access.

3 Click Submit.
Use Network Time Protocol (NTP) to automatically sync MFP date and time settings with a trusted clock so that Kerberos requests and audit log events will be accurately time‑stamped.
1 From the Embedded Web Server, click Settings > Security > Set Date and Time.
2 In the Network Time Protocol section, select the Enable NTP check box, and then type the IP address or host name of the NTP Server.
3 If the NTP server requires authentication, then select MD5 key or Autokey IFF from the Authentication drop‑down menu.
a Click Install MD5 key or Install Autokey IFF params, and then browse to the file containing the NTP
authentication credentials. b Click Submit.
4 Click Submit.
> Security > Set Date and Time.
2 Set Enable NTP to On.
3 Touch the NTP Server field, type the IP address or host name of the NTP server, and then touch Submit.
4 If the NTP server requires authentication, then set Enable Authentication to On.
5 Touch Submit.
If you will be using LDAP+GSSAPI or Common Access Cards to control user access to the MFP, then you must first configure Kerberos.
1 From the Embedded Web Server, click Settings > Security > Security Setup.
2 Under Advanced Security Setup, at Step 1, click Kerberos 5.

3 Under Simple Kerberos Setup, for KDC Address, type the IP address or host name of the KDC (Key Distribution Center) IP.
4 For KDC Port, type the number of the port used by the Kerberos server.
5 For Realm, type the realm used by the Kerberos server.
6 Click Submit to save the information as a krb5.conf file.
Using the EWS, you can also import a krb5.conf file rather than configure the Simple Kerberos Setup.
1 From the Embedded Web Server, click Settings > Security > Security Setup.
2 Under Advanced Security Setup, at Step 1, click Kerberos 5.
3 Under Import Kerberos File, click Browse to navigate to your stored krb5.conf file.
4 Click Submit to upload the krb5.conf file.
Simple Kerberos settings can be configured or adjusted using the touch screen.
> Security > Edit Security Setups > Edit Building Blocks > Simple Kerberos Setup.
2 Type the KDC (Key Distribution Center) IP address or host name, and then touch Done.
3 Type the number of the port used by the Kerberos server, and then touch Done.
4 Type the realm used by the Kerberos server, and then touch Done.
1 From the Embedded Web Server, click Settings > Security > Security Audit Log.
2 Select the Enable Audit check box.

3 Type the IP address or host name of the Remote Syslog Server, and then select the Enable Remote Syslog check box.
4 Type the Remote Syslog Port number used on the destination server.
5 For Remote Syslog Method, select Normal UDP or Stunnel (if implemented on the destination server).
6 For “Severity of events to log,” select 5 ‑ Notice. The chosen severity level and anything higher (0–4) will be logged.
7 To send all events regardless of severity to the remote server, select the Remote Syslog non‑logged events check box.
8 To automatically notify administrators about certain log events, type one or more e-mail addresses (separated by commas) in the “Admin's e‑mail address” field, and then choose how events will be handled:
9 Click Submit.
> Security > Security Audit Log > Configure Log.
2 Set Enable Audit to Yes.
3 Set Enable Remote Syslog to Yes.
4 Touch the Remote Syslog Server field, type the IP address or host name of the remote syslog server, and then touch Submit.
5 Touch the Remote Syslog Port field, type the remote syslog port number used on the destination server, and then touch Submit.
6 For Remote Syslog Method, select Normal UDP or Stunnel (if implemented on the destination server).
7 For “Log full behavior,” select Wrap over oldest entries or E‑mail log then delete all entries.
8 If you want the MFP to automatically notify administrators of certain log events, touch the Admin's e‑mail address field, type one or more e-mail addresses (separated by commas), and then touch Submit.

9 If you want the MFP to add a digital signature to e-mail alerts, then set “Digitally sign exports” to On.
10 For “Severity of events to log,” select 5 ‑ Notice. The chosen severity level and anything higher (0–4) will be logged.
11 If you want the MFP to send all events regardless of severity to the remote server, then set “Remote Syslog non‑logged events” to Yes.
12 If you want the MFP to automatically notify administrators of certain log events, then adjust the following settings as needed:
13 Touch Submit.
User data sent by the MFP using e-mail must be sent as an attachment.
1 From the Embedded Web Server, click Settings > E‑mail/FTP Settings > E‑mail Settings.
2 Under E-mail Settings, select Attachment for “E‑mail images sent as.”
1 From the Embedded Web Server, click Settings > E-mail/FTP Settings > SMTP Setup.
2 Under SMTP Setup, type the IP address or host name of the Primary SMTP Gateway the MFP will use for sending e-mail.

3 Type the Primary SMTP Gateway Port number of the destination server.
4 If you are using a secondary or backup SMTP server, then type the IP address or host name and SMTP port for that server.
5 For SMTP Timeout, type the number of seconds (5–30) the device will wait for a response from the SMTP server before timing out.
6 If you want to receive responses to messages sent from the MFP (in case of failed or bounced messages), then type a Reply Address.
7 From the Use SSL/TLS list, select Disabled, Negotiate or Required to specify whether e-mail will be sent using an encrypted link.
8 If the SMTP server requires user credentials, then select an authentication method from the SMTP Server Authentication list.
9 From the Device‑Initiated E‑mail list, select Use Device SMTP Credentials.
10 From the User‑Initiated E‑mail list, select the option most appropriate for your network or server environment.
11 If the MFP must provide credentials in order to send e-mail, then enter the information appropriate for your network under Device Credentials.
> Settings > E-mail Settings > E-mail Server Setup > Web Link Setup.
3 Touch Back, and then touch Back again to return to the E-mail Settings screen.
4 Set E‑mail images sent as to Attachment.
5 Touch Submit.
> Network/Ports > SMTP Setup.
2 Touch the Primary SMTP Gateway field, type the IP address or host name of the primary SMTP gateway the MFP will use for sending e-mail, and then touch Submit.
3 Touch the Primary SMTP Gateway Port field, type the primary SMTP gateway port number of the destination server, and then touch Submit.
4 If you are using a secondary or backup SMTP server, then provide the IP address or host name and the SMTP port number for that server.
5 For SMTP Timeout, select the number of seconds (5–30) the MFP will wait for a response from the SMTP server before timing out.

6 If you want to receive responses to messages sent from the MFP (in case of failed or bounced messages), then provide a Reply Address.
7 Set Use SSL to Disabled, Negotiate or Required to specify whether e-mail will be sent using an encrypted link.
8 If the SMTP server requires user credentials, then select a method for SMTP Server Authentication.
9 Set Device‑Initiated E‑mail to Use Device SMTP Credentials.
10 For User‑Initiated E‑mail, select the option most appropriate for your network or server environment.
11 If the MFP must provide credentials in order to send e-mail, then enter the information appropriate for your network in the “Device Userid,” “Device password,” and “Kerberos 5 Realm” or “NTLM Domain” fields.
12 Touch Submit.
If your MFP includes fax capabilities and is attached to a phone line, then you must disable fax forwarding, enable held faxes, and disable driver to fax.
1 From the Embedded Web Server, click Settings > Fax Settings > Analog Fax Setup.
2 Under Fax Receive Settings, click Holding Faxes.
3 Set Held Fax Mode to Always On.
4 Click Submit to save your changes and return to the Settings page.
5 Under Fax Send Settings, clear the Driver to fax check box.
6 Under Fax Receive Settings, select Print from the Fax Forwarding list.
7 Click Submit.
> Settings > Fax Settings > Analog Fax Setup > Fax Receive Settings > Holding Faxes.
2 Set Held Fax Mode to Always On.
3 Touch Submit to save your changes and return to the Fax Receive Settings screen.
4 Set Fax Forwarding to Print.
5 Touch Submit to save your changes and return to the Analog Fax Setup screen.
6 Touch Fax Send Settings.
7 Set “Driver to fax” to No.
8 Touch Submit.

1 Turn off the MFP using the power switch.
2 Simultaneously press and hold the 2 and 6 keys on the numeric keypad while turning the MFP back on. It takes approximately a minute to boot into the Configuration menu.
Once the MFP is ready, the touch screen displays a list of functions instead of standard home screen icons such as Copy and Fax.
3 Verify that the MFP is in Configuration mode by locating the Exit Config Menu icon in the lower right corner of the touch screen.
4 Touch Fax Storage Location.
5 Set Fax Storage Location to Disk, and then touch Submit.
The MFP returns to the main Configuration menu.
6 Touch Back, and then touch Exit Config Menu.
The MFP will undergo a power‑on reset and then return to normal operating mode.
The security reset jumper is a hardware jumper located on the motherboard that can be used to reset the security settings on the device.
> Security > Miscellaneous Security Settings.
3 Touch Submit to save the changes.
Administrators and users are required to log in to the MFP using a method that provides both authentication and authorization. Under the evaluated configuration, three options are available for granting access to network‑connected devices: internal accounts, LDAP+GSSAPI, and PKI Authentication (used with DoD Common Access Cards).
Creating internal (device) accounts for use with the evaluated configuration involves not only assigning a user ID and password to each user, but also segmenting users into groups. When configuring security templates, you will select one or more of these groups, and then you will apply a security template to each device function to control access to that function. The MFP supports a maximum of 250 user accounts and 32 user groups.

Example: Employees in the warehouse will be given access to black‑and‑white printing only, administrative office staff will be able to print in black and white and send faxes, and employees in the marketing department will have access to black‑and‑white printing, color printing, and faxing.
Security template Groups included in template Template will be applied to
color_user Marketing Copy Color Printing
When creating internal accounts in Scenario 1, you would select the group that corresponds to the user's department.
Security template Groups included in template Template will be applied to
basic_user black_and_white Copy Function
color_user color Copy Color Function
fax_user fax Fax Function
When creating internal accounts in Scenario 2, you would select the following groups for each type of user:
1 From the Embedded Web Server, click Settings > Security > Security Setup.
2 Under Advanced Security Setup, Step 1, click Internal Accounts.
3 Click Setup groups for use with internal accounts.
4 Type a Group Name.
5 Click Add.
6 Repeat the steps as needed to add more groups.
1 From the Embedded Web Server, click Settings > Security > Security Setup.
2 Under Advanced Security Setup, Step 1, click Internal Accounts.
3 From the Required User Credentials list, select User ID and password.
4 Click Submit.
Copy Function · Fax Function

5 Click Settings > Security > Security Setup > Internal Accounts.
7 Click Submit.
On networks running Active Directory, you can use LDAP+GSSAPI to take advantage of authentication and authorization services already deployed on the network. User credentials and group designations can be pulled from your existing system, making access to the MFP as seamless as other network services.
Supported devices can store a maximum of five LDAP+GSSAPI configurations. Each configuration must have a unique name.
1 From the Embedded Web Server, click Settings > Security > Security Setup.
2 Under Advanced Security Setup, Step 1, click LDAP+GSSAPI.
3 Click Add an LDAP+GSSAPI Setup.
4 Configure the following LDAP+GSSAPI Server Setup settings:
General Information

Search specific object classes (optional)
Administrators can associate as many as 32 named groups stored on the LDAP server.
5 Click Submit.
> Security > Edit Security Setups > Edit Building Blocks > LDAP+GSSAPI.
2 Touch Add Entry.
3 Type a setup name, and then touch Done. This name will be used to identify this particular LDAP+GSSAPI Server Setup when creating security templates.
4 For Server Address, type the IP address or host name of the LDAP server where authentication will be performed, and then touch Done. The MFP returns to the General Information screen.
Device Credentials (optional) · LDAP Group Names

Touch Submit to save the settings and return to the General Information screen.
Touch Done to save the settings and return to the General Information screen.
Touch Submit to save the settings and return to the General Information screen.
When creating security templates, you will select groups from this setup to control access to device functions.

A set of Public Key Infrastructure (PKI) embedded applications comes installed on the MFP. These applications provide for additional functionality, including the use of Smart Cards such as the Department of Defense Common Access Card (CAC). For more information on using a card reader with your MFP, see “Using a Common Access Card to access the printer” on page 50.
The authentication token application comes in a “Stopped” state and must be started before you configure PKI Authentication.
1 From the Embedded Web Server, click Settings > Device Solutions > Solutions (eSF).
2 On the Solutions tab, verify that the authentication token is not running. If it is not, then select the check box next to the application, and then click Start.
After the Solutions tab reloads, the authentication token application should be listed as “Running.”
PKI Authentication provides the login screen and authentication mechanism and supports user authorization to the MFP and its functions.
1 From the Embedded Web Server, click Settings > Device Solutions > Solutions (eSF).
2 Select the check box next to the PKI Authentication application, and then click Start. When the Solutions tab reloads, PKI Authentication should be in a “Running” state.
3 From the Solutions tab, click PKI Authentication > Configure.
4 For Logon Type, select Card Only so that users will be required to insert a Common Access Card to access the MFP.
5 Select whether the Card PIN can be numeric only or alphanumeric.
6 If you want to, provide a custom Logon Screen Text with special instructions for users or a custom Logon Screen Image. Custom screen images must be in GIF format and must not be larger than 800 x 320 pixels.
7 Clear the Allow Copy without Card and the Allow Fax without Card check boxes.
8 Set “User Validation Mode” to Active Directory.
9 Select the Use Device Kerberos Setup check box to use the Kerberos settings already configured on the MFP, or clear the check box to use Simple Kerberos Setup.

11 If users are allowed to log in manually, then provide at least one Manual Login Domain (a Windows Domain Name) to choose from when logging in. Multiple domains can be entered, separated by commas.
14 In the User Session and Access Control section, verify that the Share Session with LDD check box is not selected.
15 If DNS is not enabled on the network, or if some servers are multi‑homed, then under Advanced Settings, click Browse to locate a Hosts File with host name–IP address mappings.
16 Select the Wait for Active Network check box to display Waiting for network on the touch screen after the MFP is turned on. This message disappears when the network becomes available.
17 Click Apply.

A security template is assigned to each device function to control which users are permitted to access that function. At a minimum, you must create two security templates: one for "Administrator_Only" and one for "Authenticated_Users." If there is a need to grant access to some functions while restricting others, then you can create additional security templates, such as “Administrator_Reports” or “Color_User.” Each template will be populated with groups containing users authorized to access the functions protected by that template. A “PKI Authentication” security template is created automatically when you configure PKI Authentication.
1 From the Embedded Web Server, click Settings > Security > Security Setup.
2 Under Advanced Security Setup, Step 2, click Security Template.
3 Under Manage Security Templates, click Add a Security Template.
4 In the Security Template Name field, type a unique name for the template. It can be helpful to use a descriptive name, such as “Administrator_Only” or “Authenticated_Users.”
5 From the Authentication Setup list, select a method for authenticating users. This list will be populated with the authentication building blocks that have been configured on the MFP (internal accounts, LDAP+GSSAPI, or PKI Authentication).
6 Click Add authorization, and then select an option from the Authorization Setup list. This list will be populated with the authentication building blocks that have been configured on the MFP (internal accounts, LDAP+GSSAPI, or PKI Authentication).
7 Click Modify Groups, and then select one or more groups to include in the security template. Hold down the Ctrl key to select multiple groups.
8 Click Save Template.
1 From the Embedded Web Server, click Settings > Security > Security Setup.
2 Under Advanced Security Setup, Step 2, click Security Template.
3 Select a security template from the list.
4 Edit the fields as necessary.
5 Click Modify to save your changes, Delete Entry to delete the template, or Cancel to retain previously configured values.

PKI Held Jobs, also referred to as Release Print Jobs, is used to securely hold documents at the printer until released by an authorized user.
1 From the Embedded Web Server, click Settings > Device Solutions > Solutions (eSF) > PKI Held Jobs > Configure.
2 If you want to, specify custom icon text that will appear above the Held Jobs icon on the printer home screen.
3 To select an alternate image for the Up Icon (the image that appears when the Held Jobs icon has not been pressed), click Browse to locate the image you want to use. To view the default icon image, click View Current Value.
4 To select an alternate image for the Down Icon (the image that displays when the Held Jobs icon is pressed), click Browse to locate the image you want to use. To view the default icon image, click View Current Value.
5 For Access Control, select Solution‑specific access control 1.
7 Note that there are four types of held jobs: Confidential Print, Reserve Print, Verify Print, and Repeat Print. The expiration of Confidential and Reserve Print jobs is controlled by the Confidential Print Setup (Settings > Security > Confidential Print Setup).
By default, only Confidential Print jobs can be set to expire. Using Job Expiration, you can also set Verify Print and Repeat Print jobs to expire, either at the same time Confidential jobs expire or at another time:
Note: The interval chosen for Job Expiration represents the minimum time a job will be held before being removed. Depending on how often a specific device polls for state changes, jobs marked for removal may remain on the device for up to an hour after the time chosen for expiration. For example, if held jobs are set to expire after an hour, then it will actually be between one and two hours before an expiring job is removed.

8 Under Advanced Settings, select the Require All Jobs to be Held and Clear Print Data check boxes.
9 Click Apply.
Access to MFP functions can be restricted by applying security templates to individual functions. A list of access controls and what they do can be found in “Access controls” on page 47.
1 From the Embedded Web Server, click Settings > Security > Security Setup.
2 Under Advanced Security Setup, Step 3, click Access Controls.
3 Click Expand All to see all available access controls.
4 Select the appropriate level of protection for each function, as specified in the following table.
5 Click Submit.
Levels of protection include:
Access control Level of protection
Security Menu at the Device Administrator access only
Security Menu Remotely Administrator access only
Service Engineer Menus at the Device Administrator access only
Service Engineer Menus Remotely Administrator access only
Paper Menu at the Device Authenticated users only
Paper Menu Remotely Authenticated users only
Reports Menu at the Device Administrator access only
Reports Menu Remotely Administrator access only
Settings Menu at the Device Administrator access only
Settings Menu Remotely Administrator access only
Configuration Menu Disabled


Option Card Configuration at the Device Administrator access only



Access control Level of protection
Use Profiles Authenticated users only
Change Language from Home Screen Authenticated users only
Cancel Jobs at the Device Administrator access only
PictBridge Printing Not applicable–USB port disabled
Access control Level of protection
Solution 1 Authenticated users only
Solutions 2–10 Administrator access only
New Solutions Administrator access only

Login issues
M AKE SURE A SUPPORTED S MART C ARD READER IS ATTACHED
Only the OmniKey reader that came with the printer is supported. Remove the unsupported reader and attach the OmniKey reader.
The printer home screen fails to return to a locked state when not in use
Try one or more of the following:
1 From the Embedded Web Server, click Settings > Device Solutions > Solutions (eSF).
1 From the Embedded Web Server, click Settings > Device Solutions > Solutions (eSF).
2 Verify that the PKI Authentication solution appears in the list of installed solutions and that it is in a “Running” state.
MAKE SURE THE SMART CARD IS RECOGNIZED BY THE READER
Contact the Lexmark Solutions Help Desk for assistance.

“The KDC and MFP clocks are different beyond an acceptable range; check the MFP's date and time” error message
This error indicates that the printer clock is more than five minutes out of sync with the domain controller clock.
1 From the Embedded Web Server, click Settings > Security > Set Date and Time.
2 If you have manually configured date and time settings, then verify and correct them as needed. Make sure the time zone and daylight savings time settings are correct.
3 If you have configured the printer to use an NTP server, then verify that those settings are correct and that the NTP server is functioning correctly.
4 Click Submit to save any needed changes.
This error occurs when PKI Authentication is configured to use the Device Kerberos Setup, but no Kerberos file has been uploaded.
1 From the Embedded Web Server, click Settings > Device Solutions > Solutions (eSF) > PKI Authentication > Configure.
2 If the Simple Kerberos Setup has been configured in PKI Authentication, then clear the Use Device Kerberos Setup check box, and then click Apply.
3 If a Kerberos configuration file is needed, then: a From the Embedded Web Server, click Settings > Security > Security Setup > Kerberos 5. b Under Import Kerberos File, click Browse to locate the appropriate krb5.conf file, and then click Submit.
MAKE SURE THE REALM SPECIFIED IN THE KERBEROS SETTINGS IS IN UPPERCASE
1 From the Embedded Web Server, click Settings > Device Solutions > Solutions (eSF) > PKI Authentication > Configure.
2 If the Simple Kerberos Setup has been used, then verify that the Realm is correct and has been typed in uppercase.
3 If a krb5.conf file has been uploaded, then verify that the Realm entries in the configuration file are in uppercase.

MAKE SURE THAT THE CORRECT CERTIFICATE HAS BEEN INSTALLED ON THE PRINTER
For information on installing, viewing, or modifying certificates, see “Creating and modifying digital certificates” on page 15.
Try one or more of the following:
MAKE SURE THE IP ADDRESS OR HOST NAME OF THE KDC IS CORRECT
1 From the Embedded Web Server, click Settings > Device Solutions > Solutions (eSF) > PKI Authentication > Configure.
2 If the Simple Kerberos Setup has been configured in PKI Authentication, then verify the IP address or host name specified for the Domain Controller, and then click Apply to save any needed changes.
3 If a krb5.conf file has been uploaded, then verify that the IP address or host name specified for the Domain Controller is correct.
You can specify multiple KDCs in the PKI Authentication settings or in the krb5.conf file. This will typically resolve the issue.
Port 88 must be opened between the printer and the KDC for authentication to work.
MAKE SURE THE WINDOWS DOMAIN IS SPECIFIED IN THE KERBEROS SETTINGS
1 From the Embedded Web Server, click Settings > Device Solutions > Solutions (eSF) > PKI Authentication > Configure.
2 Under Simple Kerberos Setup, add the Windows Domain in lowercase to the Domain setting.
Example: If the Domain setting is mil,.mil and the Windows Domain is x.y.z, then change the Domain setting to mil,.mil,x.y.z.
3 If you are using a krb5.conf file, then add an entry to the domain_realm section, mapping the lowercase Windows Domain to the uppercase realm (similar to the existing mapping for the “mil” domain).

“Realm on the card was not found in the Kerberos Configuration File” error message
This error occurs during Smart Card login.
UPLOAD A KERBEROS CONFIGURATION FILE AND MAKE SURE THE REALM HAS BEEN ADDED TO THE FILE
The PKI Authentication settings do not support multiple Kerberos Realm entries. If multiple realms are needed, then you must create and upload a krbf5.conf file containing the needed realms. If you are already using a Kerberos configuration file, then verify that the missing realm has been added to the file correctly.
This error indicates that the KDC being used to authenticate the user does not recognize the User Principal Name specified in the error message.
1 From the Embedded Web Server, click Settings > Device Solutions > Solutions (eSF) > PKI Authentication > Configure.
2 If the Simple Kerberos Setup has been configured, then verify that the IP address or host name of the Domain Controller is correct.
3 If you are using a Kerberos configuration file, then verify that the Domain Controller entry is correct.
For information about LDAP‑related issues, see“LDAP issues” on page 41.
I NCREASE THE P ANEL L OGIN T IMEOUT INTERVAL
1 From the Embedded Web Server, click Settings > Security > Miscellaneous Security Settings > Login Restrictions.
2 Increase the time (in seconds) of the Panel Login Timeout setting, and then click Submit to save your changes.

This issue can occur during login (at “Getting User Info”) or during address book searches. Try one or more of the following:
MAKE SURE PORT 389 (NON‑SSL) AND PORT 636 (SSL) ARE NOT BLOCKED BY A FIREWALL
The printer uses these ports to communicate with the LDAP server. The ports must be open for LDAP lookups to work.
MAKE SURE THE LDAP SEARCH BASE IS NOT TOO BROAD IN SCOPE
Narrow the LDAP search base to the lowest possible scope that will include all necessary users.
This issue can occur during address book searches, user e-mail address searches, or user home directory searches. Try one or more of the following:
VERIFY THAT THE ADDRESS BOOK SETUP CONTAINS THE HOST NAME FOR THE LDAP SERVER
1 From the Embedded Web Server, click Settings > Network/Ports > Address Book Setup.
2 Verify that the host name (not the IP address) of the LDAP server has been entered in the Server Address field.
3 Click Submit to save any needed changes.
1 From the Embedded Web Server, click Settings > Network/Ports > Address Book Setup.
3 Click Submit to save any needed changes.
Narrow the LDAP search base to the lowest possible scope that will include all necessary users.
Verify that the LDAP attributes for the user's e-mail address and home directory are correct.

A DD THE USER TO THE APPROPRIATE A CTIVE D IRECTORY GROUP
If user authorization is enabled for Held Jobs, then add the user to an Active Directory group that is included in the authorization list for the Held Jobs function.
MAKE SURE PKI AUTHENTICATION IS SETTING THE USER ID FOR THE SESSION
1 From the Embedded Web Server, click Settings > Device Solutions > Solutions (eSF) > PKI Authentication > Configure.
2 In the User Session and Access Control section, for the Session Userid setting, specify how the Windows user ID will be obtained when a user attempts to log in:
3 Click Apply to save any needed changes.
Try one or more of the following:
Normally, LDAP lookup is used to set this value.
1 From the Embedded Web Server, click Settings > Device Solutions > Solutions (eSF) > PKI Authentication > Configure.
2 In the User Session and Access Control section, select LDAP Lookup for the Session Userid setting.
3 Click Apply to save any needed changes.
MAKE SURE THE JOBS WERE SENT TO THE CORRECT PRINTER AND WERE PRINTED
The user may have sent the job or jobs to a different printer, or the jobs may have been automatically deleted because they were not printed quickly enough.

Try one or more of the following:
1 From the Embedded Web Server, click Settings > Device Solutions > Solutions (eSF).
1 From the Embedded Web Server, click Settings > Device Solutions > Solutions (eSF) > PKI Held Jobs > Configure.
2 Under Advanced Settings, select the Require All Jobs to be Held and Clear Print Data check boxes.
3 Click Apply.

Understanding the home screen
The screen located on the front of the MFP is touch‑sensitive and can be used to access device functions and navigate settings and configuration menus. The home screen looks similar to this (yours may contain additional icons):

on the lower right to access settings and configuration menus for the device.
Some device settings require one or more alphanumeric entries, such as server addresses, user names, and passwords. When an alphanumeric entry is needed, a keyboard appears:

~ 1 2 3 4 5 6 7 8 9 0 - =
! @ # $ % ^ & * ( ) _ +
Q W E R T Y U I O P [ ] \
A S D F G H J K L ; Clear
Backspace Z X C V B N M , . /
As you touch the letters and numbers, your selections appear in a corresponding field at the top of the screen. The keyboard display may also contain other icons, such as Next, Submit, Cancel, and the home icon.

To type a single uppercase or shift character, touch Shift, and then touch the letter or number you need to uppercase. To turn on Caps Lock, touch Caps, and then continue typing. Caps Lock will remain engaged until you touch Caps again.
~ 1 2 3 4 5 6 7 8 9 0 - =
! @ # $ % ^ & * ( ) _ +
Q W E R T Y U I O P [ ] \
: “
A S D F G H J K L ; Clear
Backspace Z X C V B N M , . /
.com .org Space
Touch Backspace to delete a single character or Clear to delete everything you have typed.



Access controls
Depending on the device type and installed options, some access controls (referred to on some devices as Function Access Controls) may not be available for your printer.
Function access control What it does
Configuration Menu This protects access to the Configuration Menu.
Manage Shortcuts at the Device This protects access to the Manage Shortcuts section of the Settings menu from the printer control panel.
Manage Shortcuts Remotely This protects access to the Manage Shortcuts section of the Settings menu from the Embedded Web Server.
Network/Ports Menu at the Device This protects access to the Network/Ports section of the Settings menu from the printer control panel.
Network/Ports Menu Remotely This protects access to the Network/Ports section of the Settings menu from the Embedded Web Server.
NPA Network Adapter Setting Changes
When disabled, all network adapter NPA settings change commands are ignored.
Option Card Configuration at the Device
This controls access to the Option Card Configuration section of the Settings menu from the printer control panel. This applies only when an Option Card with configuration options is installed on the device.
Option Card Configuration Remotely This controls access to the Option Card Configuration section of the Settings menu from the Embedded Web Server. This applies only when an Option Card with configuration options is installed on the device.
Paper Menu at the Device This protects access to the Paper menu from the printer control panel.
Paper Menu Remotely This protects access to the Paper menu from the Embedded Web Server.
Remote Certificate Management When disabled, it is no longer possible to manage certificates using remote management tools. Certificate Management is limited to the operations available from the printer control panel and Embedded Web Server.
Reports Menu at the Device This protects access to the Reports menu from the printer control panel.
Reports Menu Remotely This protects access to the Reports menu from the Embedded Web Server.
Security Menu at the Device This protects access to the Security menu from the printer control panel.
Security Menu Remotely This protects access to the Security menu from the Embedded Web Server.
Service Engineer Menus at the Device This protects access to the Service Engineer menu from the printer control panel.
Service Engineer Menus Remotely This protects access to the Service Engineer menu from the Embedded Web Server.
Settings Menu at the Device This protects access to the General and Print Settings sections of the Settings menu from the printer control panel.

Function access control What it does
Settings Menu Remotely This protects access to the General and Print Settings sections of the Settings menu from the Embedded Web Server.
Supplies Menu at the Device This protects access to the Supplies menu from the printer control panel.
Supplies Menu Remotely This protects access to the Supplies menu from the Embedded Web Server.
Function access control What it does
Firmware Updates This controls the ability to update firmware from any source other than a flash drive. Firmware files that are received through FTP, the Embedded Web Server, etc., will be ignored (flushed) when this function is protected.
Operator Panel Lock This protects access to the locking function of the printer control panel. If this is enabled, then users with appropriate credentials can lock and unlock the printer touch screen. In a locked state, the touch screen displays only the "Unlock Device" icon, and no further operations can be performed at the device until appropriate credentials are entered. Once unlocked, the touch screen will remain in an unlocked state even if the user logs out of the device. To enable the control panel lock, the user must select the "Lock Device" icon, and then enter the appropriate credentials.
PJL Device Setting Changes When disabled, all device settings changes requested by incoming print jobs are ignored.
Remote Management This controls access to printer settings and functions by remote management tools such as MarkVisionTM. When protected, no printer configuration settings can be altered except through a secured communication channel (such as that provided by a properly configured installation of MarkVision).
Solutions Configuration or eSF Configuration
This controls access to the configuration of any installed solutions.
Web Import/Export Settings This controls the ability to import and export printer settings files (UCF files) from the Embedded Web Server.
Function access control What it does
Address Book This controls the ability to perform address book searches in the Scan to Fax and Scan to E‑mail functions.
Cancel Jobs at the Device This controls the ability to cancel jobs from the printer control panel.
Change Language from Home Screen This controls access to the Change Language feature from the printer control panel.
Color Dropout This controls the ability to use the Color Dropout feature for scan and copy functions.
Copy Color Printing This controls the ability to perform color copy functions. Users who are denied will have their copy jobs printed in black and white.
Copy Function This controls the ability to use the Copy function.
Create Bookmarks at the Device This controls the ability to create new bookmarks from the printer control panel.
Create Bookmarks Remotely This controls the ability to create new bookmarks from the Bookmark Setup section of the Settings menu on the Embedded Web Server.

Function access control What it does
Create Profiles This controls the ability to create new profiles.
E‑mail Function This controls access to the Scan to E‑mail function.
Fax Function This controls access to the Scan to Fax function.
Flash Drive Color Printing This controls the ability to print color from a flash drive. Users who are denied will have their print jobs printed in black and white.
Flash Drive Firmware Updates This controls the ability to update firmware from a flash drive.
Flash Drive Print This controls the ability to print from a flash drive.
Flash Drive Scan This controls the ability to scan documents to a flash drive.
FTP Function This controls access to the Scan to FTP function.
Held Jobs Access This protects access to the Held Jobs function.
PictBridge Printing This controls the ability to print from an attached PictBridge‑enabled digital camera.
Release Held Faxes This controls the ability to release (print) held faxes.
Use Profiles This controls access to profiles, such as scanning shortcuts, workflows, and eSF applications.
Function access control What it does
New Solutions This controls the initial security profile of each solution‑specific access control installed on the printer.
Solution 1–10 The Solution 1 through Solution 10 access controls can be assigned to installed eSF applications and profiles created by LDSS. The access control for each solution is assigned in the creation or configuration of the application or profile.

Using a Common Access Card to access the printer
1 Insert your Common Access Card into the card reader attached to the printer.
2 When prompted, enter your PIN using the keypad that appears on the touch screen, and then touch Next.
It may take a moment for the printer to validate your credentials. After your credentials have been validated, the printer will return to the home screen.

PLEASE READ CAREFULLY BEFORE INSTALLING AND/OR USING THIS SOFTWARE: This Software License Agreement ("License Agreement") is a legal agreement between you (either an individual or a single entity) and Lexmark International, Inc. ("Lexmark") that, to the extent your Lexmark product or Software Program is not otherwise subject to a written software license agreement between you and Lexmark or its suppliers, governs your use of any Software Program installed on or provided by Lexmark for use in connection with your Lexmark product. The term "Software Program" includes machine-readable instructions, audio/visual content (such as images and recordings), and associated media, printed materials and electronic documentation.
BY USING AND/OR INSTALLING THIS SOFTWARE, YOU AGREE TO BE BOUND BY ALL THE TERMS AND CONDITIONS OF THIS LICENSE AGREEMENT. IF YOU DO NOT SO AGREE, DO NOT INSTALL, COPY, DOWNLOAD, OR OTHERWISE USE THE SOFTWARE PROGRAM. IF YOU DO NOT AGREE WITH THE TERMS OF THIS LICENSE AGREEMENT, PROMPTLY RETURN THE PRODUCT UNUSED AND REQUEST A REFUND OF THE AMOUNT YOU PAID. IF YOU ARE INSTALLING THIS SOFTWARE PROGRAM FOR USE BY OTHER PARTIES, YOU AGREE TO INFORM THE USERS THAT USE OF THE SOFTWARE PROGRAM INDICATES ACCEPTANCE OF THESE TERMS.
1 STATEMENT OF LIMITED WARRANTY. Lexmark warrants that the media (e.g., diskette or compact disk) on which the Software Program (if any) is furnished is free from defects in materials and workmanship under normal use during the warranty period. The warranty period is ninety (90) days and commences on the date the Software Program is delivered to the original end-user. This limited warranty applies only to Software Program media purchased new from Lexmark or an Authorized Lexmark Reseller or Distributor. Lexmark will replace the Software Program should it be determined that the media does not conform to this limited warranty. 2 DISCLAIMER AND LIMITATION OF WARRANTIES. EXCEPT AS PROVIDED IN THIS LICENSE AGREEMENT AND TO THE MAXIMUM EXTENT PERMITTED BY APPLICABLE LAW, LEXMARK AND ITS SUPPLIERS PROVIDE THE SOFTWARE PROGRAM "AS IS" AND HEREBY DISCLAIM ALL OTHER WARRANTIES AND CONDITIONS, EITHER EXPRESS OR IMPLIED, INCLUDING, BUT NOT LIMITED TO, TITLE, NON-INFRINGEMENT, MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE, AND ABSENCE OF VIRUSES, ALL WITH REGARD TO THE SOFTWARE PROGRAM. This Agreement is to be read in conjunction with certain statutory provisions, as that may be in force from time to time, that imply warranties or conditions or impose obligations on Lexmark that cannot be excluded or modified. If any such provisions apply, then to the extent Lexmark is able, Lexmark hereby limits its liability for breach of those provisions to one of the following: replacement of the Software Program or reimbursement of the price paid for the Software Program. 3 LICENSE GRANT. Lexmark grants you the following rights provided you comply with all terms and conditions of this License Agreement:
a Use. You may Use one copy of the Software Program. The term "Use" means storing, loading, installing,
executing, or displaying the Software Program. If Lexmark has licensed the Software Program to you for concurrent use, you must limit the number of authorized users to the number specified in your agreement with Lexmark. You may not separate the components of the Software Program for use on more than one computer. You agree that you will not Use the Software Program, in whole or in part, in any manner that has the effect of overriding, modifying, eliminating, obscuring, altering or de-emphasizing the visual appearance of any trademark, trade name, trade dress or intellectual property notice that appears on any computer display screens normally generated by, or as a result of, the Software Program. b Copying. You may make one (1) copy of the Software Program solely for purposes of backup, archiving, or
installation, provided the copy contains all of the original Software Program's proprietary notices. You may not copy the Software Program to any public or distributed network.

c Reservation of Rights. The Software Program, including all fonts, is copyrighted and owned by Lexmark International, Inc. and/or its suppliers. Lexmark reserves all rights not expressly granted to you in this License Agreement. d Freeware. Notwithstanding the terms and conditions of this License Agreement, all or any portion of the
Software Program that constitutes software provided under public license by third parties ("Freeware") is licensed to you subject to the terms and conditions of the software license agreement accompanying such Freeware, whether in the form of a discrete agreement, shrink-wrap license, or electronic license terms at the time of download. Use of the Freeware by you shall be governed entirely by the terms and conditions of such license. 4 TRANSFER. You may transfer the Software Program to another end-user. Any transfer must include all software components, media, printed materials, and this License Agreement and you may not retain copies of the Software Program or components thereof. The transfer may not be an indirect transfer, such as a consignment. Prior to the transfer, the end-user receiving the transferred Software Program must agree to all these License Agreement terms. Upon transfer of the Software Program, your license is automatically terminated. You may not rent, sublicense, or assign the Software Program except to the extent provided in this License Agreement. 5 UPGRADES. To Use a Software Program identified as an upgrade, you must first be licensed to the original Software Program identified by Lexmark as eligible for the upgrade. After upgrading, you may no longer use the original Software Program that formed the basis for your upgrade eligibility. 6 LIMITATION ON REVERSE ENGINEERING. You may not alter, reverse engineer, reverse assemble, reverse compile or otherwise translate the Software Program, except as and to the extent expressly permitted to do so by applicable law for the purposes of inter-operability, error correction, and security testing. If you have such statutory rights, you will notify Lexmark in writing of any intended reverse engineering, reverse assembly, or reverse compilation. You may not decrypt the Software Program unless necessary for the legitimate Use of the Software Program. 7 ADDITIONAL SOFTWARE. This License Agreement applies to updates or supplements to the original Software Program provided by Lexmark unless Lexmark provides other terms along with the update or supplement. 8 LIMITATION OF REMEDIES. To the maximum extent permitted by applicable law, the entire liability of Lexmark, its suppliers, affiliates, and resellers, and your exclusive remedy shall be as follows: Lexmark will provide the express limited warranty described above. If Lexmark does not remedy defective media as warranted, you may terminate your license and your money will be refunded upon the return of all of your copies of the Software Program. 9 LIMITATION OF LIABILITY. To the maximum extent permitted by applicable law, for any claim arising out of Lexmark's limited warranty, or for any other claim whatsoever related to the subject matter of this Agreement, Lexmark's liability for all types of damages, regardless of the form of action or basis (including contract, breach, estoppel, negligence, misrepresentation, or tort), shall be limited to the greater of $5,000 or the money paid to Lexmark or its authorized remarketers for the license hereunder for the Software Program that caused the damages or that is the subject matter of, or is directly related to, the cause of action.
IN NO EVENT WILL LEXMARK, ITS SUPPLIERS, SUBSIDIARIES, OR RESELLERS BE LIABLE FOR ANY SPECIAL, INCIDENTAL, INDIRECT, EXEMPLARY, PUNITIVE, OR CONSEQUENTIAL DAMAGES (INCLUDING BUT NOT LIMITED TO LOST PROFITS OR REVENUES, LOST SAVINGS, INTERRUPTION OF USE OR ANY LOSS OF, INACCURACY IN, OR DAMAGE TO, DATA OR RECORDS, FOR CLAIMS OF THIRD PARTIES, OR DAMAGE TO REAL OR TANGIBLE PROPERTY, FOR LOSS OF PRIVACY ARISING OUT OR IN ANY WAY RELATED TO THE USE OF OR INABILITY TO USE THE SOFTWARE PROGRAM, OR OTHERWISE IN CONNECTION WITH ANY PROVISION OF THIS LICENCE AGREEMENT), REGARDLESS OF THE NATURE OF THE CLAIM, INCLUDING BUT NOT LIMITED TO BREACH OF WARRANTY OR CONTRACT, TORT (INCLUDING NEGLIGENCE OR STRICT LIABILITY), AND EVEN IF LEXMARK, OR ITS SUPPLIERS, AFFILIATES, OR REMARKETERS HAVE BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES, OR FOR ANY CLAIM BY YOU BASED ON A THIRD-PARTY CLAIM, EXCEPT TO THE EXTENT THIS EXCLUSION OF DAMAGES IS DETERMINED LEGALLY INVALID. THE FOREGOING LIMITATIONS APPLY EVEN IF THE ABOVE-STATED REMEDIES FAIL OF THEIR ESSENTIAL PURPOSE. 10 TERM. This License Agreement is effective unless terminated or rejected. You may reject or terminate this license at any time by destroying all copies of the Software Program, together with all modifications, documentation, and merged portions in any form, or as otherwise described herein. Lexmark may terminate your license upon notice if you fail to comply with any of the terms of this License Agreement. Upon such termination, you agree to destroy

all copies of the Software Program together with all modifications, documentation, and merged portions in any form. 11 TAXES. You agree that you are responsible for payment of any taxes including, without limitation, any goods and services and personal property taxes, resulting from this Agreement or your Use of the Software Program. 12 LIMITATION ON ACTIONS. No action, regardless of form, arising out of this Agreement may be brought by either party more than two years after the cause of action has arisen, except as provided under applicable law. 13 APPLICABLE LAW. This Agreement is governed non-exclusively by the laws of the country in which you acquired the Software Program (or, if that country has a federal system of government, then this Agreement will be governed by the laws of the political subdivision in which you acquired the Software). If you acquired the Software in the United States, the laws of the Commonwealth of Kentucky shall govern. No choice of law rules in any jurisdiction will apply. 14 UNITED STATES GOVERNMENT RESTRICTED RIGHTS. The Software has been developed entirely at private expense and is provided with RESTRICTED RIGHTS. Use, duplication and disclosure by the Government is subject to restrictions as set forth in subparagraph (c) (1) (ii) of the Rights in Technical Data and Computer Software clause at DFARS 252.227-7013 and in similar FAR provisions (or any equivalent agency regulation or contract clause). 15 CONSENT TO USE OF DATA. You agree that Lexmark, its affiliates, and agents may collect and use information you provide in relation to support services performed with respect to the Software Program and requested by you. Lexmark agrees not to use this information in a form that personally identifies you except to the extent necessary to provide such services. 16 EXPORT RESTRICTIONS. You may not (a) acquire, ship, transfer, or reexport, directly or indirectly, the Software Program or any direct product therefrom, in violation of any applicable export laws or (b) permit the Software Program to be used for any purpose prohibited by such export laws, including, without limitation, nuclear, chemical, or biological weapons proliferation. 17 CAPACITY AND AUTHORITY TO CONTRACT. You represent that you are of the legal age of majority in the place you sign this License Agreement and, if applicable, you are duly authorized by your employer or principal to enter into this contract. 18 ENTIRE AGREEMENT. This License Agreement (including any addendum or amendment to this License Agreement that is included with the Software Program) is the entire agreement between you and Lexmark relating to the Software Program. Except as otherwise provided for herein, these terms and conditions supersede all prior or contemporaneous oral or written communications, proposals, and representations with respect to the Software Program or any other subject matter covered by this License Agreement (except to the extent such extraneous terms do not conflict with the terms of this License Agreement, any other written agreement signed by you and Lexmark relating to your Use of the Software Program). To the extent any Lexmark policies or programs for support services conflict with the terms of this License Agreement, the terms of this License Agreement shall control.


*3065326* PN 3065326 Rev. 001
Pages referenced in this manual — manufacturer, support and downloads.
Owners and our team usually reply within a day — and your question helps the next person too.
Be the first to ask — other owners or our team will answer.