will desensitize a receiver to noise signals with only a minimal reduction in command signal sensitivity. The result: Problems from noise interference are dramatically reduced without affecting overall system performance.
Leviton specifically denies any warranty of performance, stated or implied, where electrical noise interference exists at the time of installation, or subsequent to installation by the addition of noise-producing devices
interference in a residential installation. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to
Leviton Residential Powerline Carrier Components are designed to provide the greatest signal integrity and noise immunity possible. However, in some environments intense electrical noise can cause interference
signal window when receivers listen for command signals. Noise levels in the signal window are never as high as they are during other portions of the AC power curve. Therefore, Leviton’s Intellisense gated AGC
Cat. Nos. 6385 (Signal Test Transmitter) and 6386 (Signal Strength Indicator), and to properly apply signal coupling and noise reduction equipment according to the guidelines provided in the Decora® Home Controls
HCCS7: 7 scenes plus DIM/BRIGHTEN on 12 sequential pre-selected addresses NOTE: Cat. No. HCCxx Wall Mounted Controller is not intended to replace standard wall switches. The Controller requires one HOT (BLACK) and one NEUTRAL (WHITE) conductor for proper operation. Incorrect
Leviton DHC devices use Intellisense, a special gated-type of AGC, to help eliminate noise problems (refer Figure 1). This circuit feature is ideal for powerline carrier systems because it only operates during the
The HCCxx Transmitter incorporates Leviton’s exclusive Intellisense™ Automatic Gain Control (AGC) circuitry to deliver clearer and stronger line signals without affecting signals simultaneously on the line from
This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC rules. These limits are designed to provide reasonable protection against harmful
1. WARNING: TO AVOID FIRE, SHOCK, OR DEATH; TURN OFF POWER AT CIRCUIT BREAKER OR FUSE AND TEST THAT POWER IS OFF BEFORE WIRING! 2. Remove approximately 3/4" (1.9 cm) of insulation from circuit conductors. 3. If using a standard Decora® wallplate, remove “A” tabs from strap (refer Figure 2). If using a Decora® Plus Screwless wallplate, leave tabs intact. 4. Connect wires per WIRING DIAGRAM as follows: BLACK (Hot) wire to BLACK lead of device, and WHITE (Neutral) to White lead of device. Twist strands of each lead tightly together and, with circuit conductor, push firmly into appropriate wire connector. Screw connector on clockwise making sure that no bare wire shows below the connector. Secure each wire connector with electrical tape.
Indicator Position Diagram). The unit must be set (programmed) to allow it to communicate with devices in the Home Control System. This is accomplished by setting the controller’s transmit code to correspond with
radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be
The system communicates via a “preset code” set on transmitters (this device), and receivers (dimmers and switches). The code consists of a letter code (A, B, C, …, P) and a number code (1, 2, 3, …, 16) (refer to
The HCCxx is a signal transmitter that works in conjunction with DHC receivers. The Wall-Mounted DHC Transmitter is designed to provide manual control of loads from one or more locations in a home over
HCC4A: ON/OFF for 3 addresses in sequence, plus DIM/BRIGHTEN of each address and ALL ON/OFF control of addresses within the same letter code (10 buttons)
or equipment, or where these components have been installed for non-residential applications. Installation of a Repeater/Coupler is recommended in all DHC systems.
determined by turning the equipment OFF and ON, the user is encouraged to try to correct the interference by one or more of the following measures:
other transmitters. The resulting performance reliability exceeds that of any other powerline carrier home automation product line available today.
It is the responsibility of the specifier/installer to test for signal strength and the presence of noise using Leviton test equipment,
INSTALLATION INSTRUCTIONS
ADDRESS PROGRAMMING
with the signal. Leviton has developed hardware and techniques for overcoming this interference when properly applied.
DHC Components are for residential use only. Installation for any other application voids any warranty, stated or implied.
LEVITON’S DHC DEVICES FEATURE INTELLISENSE, THE RIGHT TYPE OF AUTOMATIC GAIN CONTROL (AGC)
DESCRIPTION
SPECIFICATIONS
FEATURES
dimmers and switches in the system it is installed in. Program as follows:
(DHC) Technical Manual and the DHC Troubleshooting Guide.
installation will void warranty.
standard 60Hz 120V wiring.
WALL MOUNTED CONTROLLER
w/Multiple Addressing
Cat. Nos.
HCC3D
HCC4A
HCC4D
HCCS7
Rated: 120VAC, 60 Hz
INSTALLATION INSTRUCTIONS
PK-93028-10-00-0B
Leviton warrants to the original consumer purchaser and not for
the benefit of anyone else that this product at the time of its sale by
Leviton is free of defects in materials and workmanship under
normal and proper use for two years from the purchase date.
Leviton’s only obligation is to correct such defects by repair or
replacement, at its option, if within such two year period the product
is returned prepaid, with proof of purchase date, and a description
of the problem to Leviton Manufacturing Co., Inc., Att: Quality
Assurance Department, 59-25 Little Neck Parkway, Little
Neck, New York 11362-2591. This warranty excludes and there
is disclaimed liability for labor for removal of this product or
reinstallation. This warranty is void if this product is installed
improperly or in an improper environment, overloaded, misused,
opened, abused, or altered in any manner, or is not used under
normal operating conditions or not in accordance with any labels
or instructions. There are no other or implied warranties of any
kind, including merchantability and fitness of a particular purpose,
but if any implied warranty is required by the applicable
jurisdiction, the duration of any such implied warranty, including
merchantability and fitness for a particular purpose, is limited to
two years. Leviton is not liable for incidental, indirect, special, or
consequential damages, including without limitation, damage to,
or loss of use of, any equipment, lost sales or profits or delay or
failure to perform this warranty obligation. The remedies provided
herein are the exclusive remedies under this warranty, whether
For Technical Assistance Call:
1-800-824-3005 www.leviton.com
based on contract, tort or otherwise.

Cat. No. HCCS7
HCCxx CONFIGURATIONS · Wall box Transmitter

B. Using the Cat. No. 6386 Signal Strength Indicator at the HCCxx location, check the command signal amplitude. Signal strength must be 100mV minimum. If there is less

C. If the Yellow ERROR CONDITION indicator is lit, there is electrical “noise” present on the AC line which is interfering with proper module operation. The source of the
than 100mV of signal present, it may be necessary to couple both legs of the 120/240 Volt power service at the entrance panel using a Leviton Repeater/Coupler.
A B C D E F G H I J K L M N O P
A. Plug the Cat. No. 6385 Signal Test Transmitter into a receptacle on the same circuit breaker as the Controller.
If the Cat. No. HCCxx Controller appears to be functioning improperly proceed with the following steps:
noise must be identified and either filtered out or eliminated (See Technical Manual).
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
b) You will see rows of BLACK buttons with a protruding plastic LED to its left. The left hand row of four buttons is used to set the Unit Codes (numbers 1-16). The right hand
turned ON. Press the switch next to corresponding LED position to turn that LED ON, (i.e., “7”, press switches 2 nd and 3 rd down from top to turn ON, LED’s next to them will
turned ON; press switch next to corresponding LED position to turn that LED ON, (i.e., “7”, press switches 1 (top right), 2nd and 4th down from top to turn ON, LED’s next to them
Pressing the scene button will transmit a SCENE ON command. Pressing another scene button will change the lighting to that programmed scene. Pressing the “OFF” button will
d) To set Unit Code: Determine code setting required (i.e., L7, Unit Code is 7). Using matrix chart (refer to Indicator Position Diagram), determine which switches should be
e) To set House Code: Determine code setting required (i.e., L7, House Code is L). Using matrix chart (refer to Indicator Position Diagram), determine which switches should be
The color of this device can be changed to suit your interior design requirements. Simply obtain a color conversion kit of the appropriate color from your Leviton distributor and
The group DIM/BRIGHT buttons (arrows) will DIM or BRIGHTEN the last selected address. To DIM or BRIGHTEN another address, press the ON button for the desired address
transmitting an OFF command, the LED will blink while the signal is being transmitted and turn OFF when the signal has completed the transmission. When the DIM or BRIGHT
Press the keypad to confirm that the load or loads are turned ON and OFF within two seconds of signal transmission. If the Cat. No. HCCxx Controller appears to be functioning
The HCCxx series can switch multiple addresses from the same Controller. The top button transmits as per the letter/number code set on the Controller. The next button down
Pressing the top ON button will transmit an ON command for the preset address. Pressing the top OFF button will transmit an OFF command for the preset address. The next
On the HCC4A, the bottom row OFF button will transmit the ALL ON/ALL OFF commands for all devices set to the same letter code (i.e., A). To adjust brightness level of LAST
When transmitting an ON/ALL ON command, the LED will blink while the signal is being transmitted and will stay ON when the signal has completed the transmission. When
An ALL ON/OFF button controls ALL DHC modules set to the same letter code as on the Cat. No. HCCxx Controller. ALL ON only turns ON lighting modules. ALL OFF turns
transmitting an OFF/ALL OFF command, the LED will blink while the signal is being transmitted and turn OFF when the signal has completed the transmission. Pressing the
When transmitting a SCENE ON command, the LED will blink while the signal is being transmitted and will stay ON when the signal has completed the transmission. When
g) To change or check set codes, press PROGRAM BUTTON again. LED’s will illuminate corresponding last set code. Repeat steps D through F if change is desired.
lower row of ON/OFF buttons will perform ON/OFF commands for the next sequential address of the one selected (i.e., first row A1, second row A2, third row A3).
A1-A12. If code “16” is reached before 12 sequential codes, it will start with 1, 2, 3 (i.e., code set to A15, cycling sequence is A15, A16, A1..A10).
TO OPERATE (Cat. Nos. HCC2D, HCC3D, HCC4A and HCC4D ONLY)
BRIGHT or DIM button will cause the LED’s on the face of the keypad to flash and will remain flashing until the button is released.
turn OFF the last selected scene. To adjust brightness level of last selected address, use DIM and BRIGHT arrows.
SCENE PROGRAMMING (Cat. No. HCCS7 ONLY)
improperly or operates erratically, read the following paragraphs, then refer to the Perfect Performance Checklist.
c) Press the recessed “PROGRAM BUTTON” once. The LED’s will flash approximately every 2 to 5 seconds.
TO OPERATE (Cat. Nos. HCCS7 ONLY)
f) Press “PROGRAM BUTTON” again. LED’s will stop flashing. Unit is now programmed to L7.
a) Remove wallplate and front face of device (refer to Color Conversion Procedure).
transmits to the same letter, next number address as set on the Controller, and so on.
row of four buttons is used to set the House Codes (letters A-P).
proceed as follows (please note that the wallplate must be removed).
i) Replace front face and wallplate. Programming is complete.
address corresponds to that device will turn ON/OFF to match.
arrow is pressed, all LED's will flash until the button is released.
selected address, use DIM and BRIGHT arrows.
and then use the group DIM/BRIGHT control.
OFF ALL modules set to the same letter code.
will illuminate and not flash.
illuminate and not flash).
Examples: