1. Introduction

Power-over-Ethernet (PoE) eliminates the need to run 110/220 VAC power to other

devices on a wired LAN. Using Power-over-Ethernet system installers need to run only

a single CAT5 Ethernet cable that carries both power and data to each device. This

allows greater flexibility in the locating of network devices and significantly decreasing

installation costs in many cases.

There are two system components in PoE -- the Power Sourcing Equipment (PSE)

initiates the connection to the second component, the Powered Device (PD). The

current is transmitted over two of the four twisted pairs of wires in a Category-5 cable.

Power over Ethernet follows the IEEE 802.3af and is completely compatible with

existing Ethernet switches and networked devices. Because the Power Sourcing

Equipment (PSE) tests whether a networked device is PoE-capable, power is never

transmitted unless a Powered Device is at other end of the cable. It also continues to

monitor the channel. If the Powered Device does not draw a minimum current,

because it has been unplugged or physically turned off, the PSE shuts down the power

to that port. Optionally, the standard permits Powered Devices to signal to the PSEs

exactly how much power they need.

Features

„ POH-0850TX, 8-port power over Ethernet Hub

„ IEEE802.3af compliance, Power over Ethernet Mid-Spain mode

„ Remote power feeding up to 100 meters and for IEEE802.3 10Base-T, IEEE

802.3u 100Base-TX standard

„ Auto detect PD and classification power consumption level

„ Support manual control port detect and classification

„ Support system calibrate

„ Support Auto MDI/MDI-X depends on the uplink switch port.

Page 4 of the LevelOne POH-0850TX user manual — Package Contents
Page 4 · click to enlarge
Page 4

„ Remote power feeding up to 100 meters and for IEEE802.3 10Base-T, IEEE

802.3u 100Base-TX standard

„ Centralized power distribution for PoE powered Device (PD)

„ High safety short circuit protection to prevent cable short

„ Supports IEEE 802.3af non-standard device, and support manual detect PD

„ Auto refresh port status and support Plug and Play feature for PD

Package Contents

Unpack the contents of the 8 port Power over Ethernet Hub and verify them

against the checklist below.

„ POS-0850TX, 8-port Power over Ethernet MidSpan Hub

„ Software Utility CD-ROM

LevelOne POH-0850TX — Package Contents diagram (page 4)
Fig. 2 · Package Contents
LevelOne POH-0850TX — Package Contents diagram (page 4)
Fig. 3 · Package Contents
LevelOne POH-0850TX — Package Contents diagram (page 4)
Fig. 4 · Package Contents

POH-0850TX RS-232 Cable Power Cord

LevelOne POH-0850TX — Package Contents diagram (page 4)
Fig. 5 · Package Contents

User Guide Software Utility CD-ROM

Figure 1-2. Package Contents

Compare the contents of your POH-0850TX package with the standard checklist

above. IF any item is missing or damaged, please contact your local dealer for service.

„ Power Cord · „ RS-232 cable · „ User Guide

Page 5 of the LevelOne POH-0850TX user manual — Front Panel
Page 5 · click to enlarge
Page 5

2. Hardware Description

This Section mainly describes the hardware of the POH-0850TX, and gives a physical

and functional overview.

Physical Dimension

The 8-port Power over Ethernet Hub physical dimension is: 440mm x 224mm x 44mm

(Lx W x H)

Front Panel

The Front Panel of the POH-0850TX consists of 8x RJ-45 Ethernet ports, LED

indicators, and one console port.

LevelOne POH-0850TX — Front Panel diagram (page 5)
Fig. 6 · Front Panel

Figure 2-1. The appearance of POH-0850TX, 8 port Power over Ethernet Hub LED Indicators

The LED Indicators gives real-time information of systematic operation status. The

following table provides descriptions of LED status and their meaning.

Page 6 of the LevelOne POH-0850TX user manual — Power On
Page 6 · click to enlarge
Page 6
LevelOne POH-0850TX — Rear Panel diagram (page 6)
Fig. 7 · Rear Panel

Figure 2-2. LED indicators

LevelOne POH-0850TX — Rear Panel diagram (page 6)
Fig. 8 · Rear Panel
LEDStatusColorDescription Power ForwardingOnGreenPower is transmitting to the device Off--Power is not transmitting to the device Power OffOnOrangeDevice is overload or short. Off--Device attached. BlinkingOrangeDetecting the device

Table 2-1. The Description of LED Indicators Notice

The “Power Off” LED is flashing when No PD attached.

And the LED goes off when PD attached. The corresponding “power forwarding” LED will then

go ON or OFF depending on switch action.

Rear Panel

The 3-pronged power plug, 2 Ventilation fan and on/off switching are located at the

rear panel of the 8 port Power over Ethernet Hub. The device will work with AC in the

range 100-240V AC, 50-60Hz.

LevelOne POH-0850TX — Rear Panel diagram (page 6)
Fig. 9 · Rear Panel

Figure 2-3 Rear panel of the POH-0850TX

Power On

Connect the power cord to the power socket on the rear panel of the Switch. The other

Page 7 of the LevelOne POH-0850TX user manual — Network Application
Page 7 · click to enlarge
Page 7

side of power cord connects to the power outlet. The internal power supply of the

Switch works with voltage range of AC in the 100-240VAC, frequency 50~60Hz. Check

the power indicator on the front panel to see if power is properly supplied.

Network Application

The Power over Ethernet Hub can provides power to the PD that follow the IEEE

802.3af standard in the network. It can solve the problem of position limitation. The

network device can be installed in more appropriate position for better performance.

The following figure is an example of network application for Power over Ethernet Hub.

LevelOne POH-0850TX — Network Application diagram (page 7)
Fig. 10 · Network Application
Powered Device, exSOHO

switch or Wireless AP

Figure 2-3 Power over Ethernet Hub network application

Core Switch

Page 8 of the LevelOne POH-0850TX user manual — 3. Software Utility Installation
Page 8 · click to enlarge
Page 8

3. Software Utility Installation

Berfore you star to remote configuring PD, please intsall the software utility. Through

the software utility, you can easily to controll the PD that connect with PoE and view

the PD parameter informations. The software utility provides GUI interface and user

can easily to start with it. The software utility supports Windows environment -- Window

98, 2000, and XP. Please follow the below steps to install the software utility.

1. Insert the software utility CD-ROM into your CD-ROM drive.
2. Run the “setup.exe”.
3. You will see the installation screen display.
4. Then, click the “OK” button to go next step. See Figure 3-1.
LevelOne POH-0850TX — 3. Software Utility Installation diagram (page 8)
Fig. 11 · 3. Software Utility Installation
5. Click the

button to start installation. See Figure 3-2.

Figure 3-1

Page 9 of the LevelOne POH-0850TX user manual — 3. Software Utility Installation
Page 9 · click to enlarge
Page 9
LevelOne POH-0850TX — 3. Software Utility Installation diagram (page 9)
Fig. 12 · 3. Software Utility Installation
6. When installation finishes, click “OK” button to finish. See Figure 3-3.
LevelOne POH-0850TX — 3. Software Utility Installation diagram (page 9)
Fig. 13 · 3. Software Utility Installation
7. To run the software utility, go to “ Star ” Æ “ Program ” Æ “ Power Over Ethernet ”.

Figure 3-2 · Figure 3-3

Page 10 of the LevelOne POH-0850TX user manual — 3. Software Utility Installation
Page 10 · click to enlarge
Page 10
8. If you want to remove the software utility, go to “ Star ” Æ “ Control Panel ” Æ

“Remove/ Add application” Æ “Power Over Ethernet”.

Page 11 of the LevelOne POH-0850TX user manual — Connecting to PoE
Page 11 · click to enlarge
Page 11

4. GUI Management

Connecting to PoE

Connecting the PoE with PC through the console port. Then, connect the PD (Powered

Device) to the port of PoE. Run the software utility and select the COM port form Serial

Link Setup function. You will see the main utility interface as figure 4-1.

LevelOne POH-0850TX — Connecting to PoE diagram (page 11)
Fig. 14 · Connecting to PoE

Figure 4-1. The GUI management interface

The GUI management is divided into three parts:

„ System Setup & Controlmain system level parameters setup for the POE

system.

„ System Informationdisplay hardware version, firmware version, and utility

version.

„ Device Settingyou can save the device configuration to system, down load the
Page 12 of the LevelOne POH-0850TX user manual — System Setup & Control
Page 12 · click to enlarge
Page 12

device current configuration to the utility system and enable auto refresh function.

„ Port Specific Controleach port specific function control and relate parameters

display.

„ Parametric Information: port parameters information display.

System Setup & Control

„ Master EnableEnable/Disable the control of GUI. You must enable this item to do

the port controlling.

„ Calibrate Systemwhen the system can’t do the port controlling, please remove the

PD device and enable this function to calibrate internal system.

„ PD Discovery R (ohms): set the PD resistor value range for the system detecting.

The default value range is 19000~26500. You can adjust the upper and lower limit

value when the system can’t detect the PD resistor in the default range. Please refer

to the “Discover R (ohms)” value in Parametric Information section to adjust the

upper and lower limit value. After you have adjusted the upper or lower limit value,

please unplug and then plug in the PD device.

LevelOne POH-0850TX — System Setup & Control diagram (page 12)
Fig. 15 · System Setup & Control

Figure 4-2. System Setup & Control interface

Page 13 of the LevelOne POH-0850TX user manual — Device Setting
Page 13 · click to enlarge
Page 13

System Information

„ Chip Version: display the system chipset version and revision information.

„ Firmware Version: display the system firmware version.

„ Utility Versiondisplay the system utility version

„ Total Port Power (W): total of all the port power that the system provided to PD.

LevelOne POH-0850TX — System Information diagram (page 13)
Fig. 16 · System Information

Figure 4-3. System Information interface

Device Setting

„ Enable Auto-Refresh: It allows the system auto refresh the system parameters.

The system auto refresh in every 2 seconds.

„ Load from DeviceTo get the last configuration value from device to the

system utility.

„ Save to DeviceWhen you have configured the System Setup & Control and

Port Specific Control, please press Save to Device button to apply the new

configuration into the system.

Page 14 of the LevelOne POH-0850TX user manual — System Information
Page 14 · click to enlarge
Page 14
LevelOne POH-0850TX — System Information diagram (page 14)
Fig. 17 · System Information

Figure 4-4 Device Setting interface

Page 15 of the LevelOne POH-0850TX user manual — Port Specific Control
Page 15 · click to enlarge
Page 15

Port Specific Control

„ Port Enableenabling the port. This function is co-responding with “Master

Enable” function.

„ Bypass Detectionbypass the detection function. Normally the system will try

to detect the 25kΩ resistor in an 802.3af compliant PD device. If the PD doesn’t

follow by IEEE 802.3af standard, you can enable this option to skip the detection

on PD. When you enable this function, the system will not perform the 25Ω

resistor detection for PD and directly transmit the power to PD. This function can

be cooperating with “PD discover R (ohms)” function in System setup & Control

section for non-standard compliant PD device.

[Note] after setting the Bypass Detection function, please unplug and then plug in

the PD device.

„ Bypass Classificationthe system will skip the power classification and directly

transmit the power to PD when this function is enabling. Normally the system will

try to classify the 802.3af compliant PD device by checking the current class level.

The following table is a standard current classification level table.

[Note] after setting the Bypass Classification function, please unplug and then plug

in the PD device.

LevelOne POH-0850TX — Port Specific Control diagram (page 15)
Fig. 18 · Port Specific Control

Table of Power Device Classification Levels

„ LED Status Indicators: current LED indicator display – green, yellow, and red.

Page 16 of the LevelOne POH-0850TX user manual — Port Specific Control
Page 16 · click to enlarge
Page 16

The LED indicator will change depends on the PD status.

¾ GreenIt represents PD is connecting with the POE hub system and working

normally.

¾ Yellow: It represents there is no PD connecting with the port.

¾ REDIt represents PD’s power request is over the system support limit or the

cable is short.

„ Fault Statusdisplay the PD error status message. There are three error status

and explain as following.

¾ NullIt means there is no PD connected or the connected PD device status is

normal.

¾ OverloadIt means the current is over the PD current classification limited

(475mA @ 48V DC) that the situation happens over 50msec.

„ Mode Status: display the PD current operation mode status.

¾ V sample or I sample: It means " Current sample or Voltage sample”.

When PD is detected and current is supplied, the POE hub will keep detecting

and sampling some current or voltage to ensure whether the PD still present

on this port. It is a IEEE 802.3af operating procedure.

¾ R detectWhen the port doesn’t connect with any PD, the POE hub will poll

each port and detects the resistor.

LevelOne POH-0850TX — Port Specific Control diagram (page 16)
Fig. 19 · Port Specific Control

Figure 4-5. Port Specific Control interface

Page 17 of the LevelOne POH-0850TX user manual — Parametric Information
Page 17 · click to enlarge
Page 17

Parametric Information

„ Discovery R (ohms): display resistance value.

„ Port Current (mA): display current value.

„ Port Voltage (V): display voltage value.

„ Port Power (W): display watt value.

„ Class Current (mA)display class current value. When you enable the “Bypass

classification” function, the class current value will not show in here. Please refer

to the following table for output value.

Maximum power of levels at

0 Default 15.4 Watts

1 Optional 4.0 Watts

2 Optional 7.0 Watts

3 Optional 15.4 Watts

4 Reserved for future use Treat as Class 0

„ Determined Classdisplay power class. When you enable the “Bypass

classification” function, the class value will not show in here.

LevelOne POH-0850TX — Parametric Information diagram (page 17)
Fig. 20 · Parametric Information

Figure 4-6. Parametric Information interface

Class Usage · output of PSE

Page 18 of the LevelOne POH-0850TX user manual — 5. Technical Specification
Page 18 · click to enlarge
Page 18

5. Technical Specification

LevelOne POH-0850TX — 5. Technical Specification diagram (page 18)
Fig. 21 · 5. Technical Specification
Data and power out8 x RJ-45. Data pin
1,2,3,6 Power pin (V+)4,5, Power pin (V-): 7,8

Plug and play for standard PD and without any

Nullno PD present or PD status is normal
Page 19 of the LevelOne POH-0850TX user manual — 5. Technical Specification
Page 19 · click to enlarge
Page 19
LevelOne POH-0850TX — 5. Technical Specification diagram (page 19)
Fig. 22 · 5. Technical Specification

Dimension 440mm x 224mm x 44mm (L x W x H)

EMI & safety FCC Class A, CE, UL, cUL

Page 20 of the LevelOne POH-0850TX user manual — 6. Appendix Console Port Pin Assignments
Page 20 · click to enlarge
Page 20

6. Appendix Console Port Pin Assignments

The female DB-9 serial port on the POE hub front panel is used to connect to the

switch for out-of-band console configuration. The web interface configuration program

can be accessed from PC running the system utility program. The pin assignments

used to connect to the serial port are provided in the following tables.

LevelOne POH-0850TX — 6. Appendix Console Port Pin Assignments diagram (page 20)
Fig. 23 · 6. Appendix Console Port Pin Assignments

Figure 6-1. DB-9 Console Port Pin Numbers

DB-9 Port Pin Assignments

LevelOne POH-0850TX — 6. Appendix Console Port Pin Assignments diagram (page 20)
Fig. 24 · 6. Appendix Console Port Pin Assignments

No other pins are used

Page 21 of the LevelOne POH-0850TX user manual — 5 SGND -----------SGND ---------- 5 SGND
Page 21 · click to enlarge
Page 21

Console Port to 9-Pin DTE Port on PC

CCITT Signal PC’s 9-Pin DTE Port

2 RXD < RXD 3 TxD

3 TXD TXD > 2 RxD

5 SGND SGND 5 SGND

No other pins are used.

Switch’s 9-Pin Serial · Port

Ask about the LevelOne POH-0850TX

Owners and our team usually reply within a day — and your question helps the next person too.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
No questions yet about the LevelOne POH-0850TX

Be the first to ask — other owners or our team will answer.

Original document

LevelOne POH-0850TX manual PDF

21 pages·768 KB·Switch·PDF
Click any page above to open it here
Page 1 / …
100%
Loading pages…