19” 8-port MidSpan POE HUB
USER MANUAL



Power-over-Ethernet (PoE) eliminates the need to run 110/220 VAC power to other
devices on a wired LAN. Using Power-over-Ethernet system installers need to run only
a single CAT5 Ethernet cable that carries both power and data to each device. This
allows greater flexibility in the locating of network devices and significantly decreasing
installation costs in many cases.
There are two system components in PoE -- the Power Sourcing Equipment (PSE)
initiates the connection to the second component, the Powered Device (PD). The
current is transmitted over two of the four twisted pairs of wires in a Category-5 cable.
Power over Ethernet follows the IEEE 802.3af and is completely compatible with
existing Ethernet switches and networked devices. Because the Power Sourcing
Equipment (PSE) tests whether a networked device is PoE-capable, power is never
transmitted unless a Powered Device is at other end of the cable. It also continues to
monitor the channel. If the Powered Device does not draw a minimum current,
because it has been unplugged or physically turned off, the PSE shuts down the power
to that port. Optionally, the standard permits Powered Devices to signal to the PSEs
exactly how much power they need.
POH-0850TX, 8-port power over Ethernet Hub
IEEE802.3af compliance, Power over Ethernet Mid-Spain mode
Remote power feeding up to 100 meters and for IEEE802.3 10Base-T, IEEE
802.3u 100Base-TX standard
Auto detect PD and classification power consumption level
Support manual control port detect and classification
Support system calibrate
Support Auto MDI/MDI-X depends on the uplink switch port.

Remote power feeding up to 100 meters and for IEEE802.3 10Base-T, IEEE
802.3u 100Base-TX standard
Centralized power distribution for PoE powered Device (PD)
High safety short circuit protection to prevent cable short
Supports IEEE 802.3af non-standard device, and support manual detect PD
Auto refresh port status and support Plug and Play feature for PD
Unpack the contents of the 8 port Power over Ethernet Hub and verify them
against the checklist below.
POS-0850TX, 8-port Power over Ethernet MidSpan Hub
Software Utility CD-ROM



POH-0850TX RS-232 Cable Power Cord

User Guide Software Utility CD-ROM
Figure 1-2. Package Contents
Compare the contents of your POH-0850TX package with the standard checklist
above. IF any item is missing or damaged, please contact your local dealer for service.
Power Cord · RS-232 cable · User Guide

This Section mainly describes the hardware of the POH-0850TX, and gives a physical
and functional overview.
The 8-port Power over Ethernet Hub physical dimension is: 440mm x 224mm x 44mm
(Lx W x H)
The Front Panel of the POH-0850TX consists of 8x RJ-45 Ethernet ports, LED
indicators, and one console port.

Figure 2-1. The appearance of POH-0850TX, 8 port Power over Ethernet Hub LED Indicators
The LED Indicators gives real-time information of systematic operation status. The
following table provides descriptions of LED status and their meaning.


Figure 2-2. LED indicators

Table 2-1. The Description of LED Indicators Notice
The “Power Off” LED is flashing when No PD attached.
And the LED goes off when PD attached. The corresponding “power forwarding” LED will then
go ON or OFF depending on switch action.
The 3-pronged power plug, 2 Ventilation fan and on/off switching are located at the
rear panel of the 8 port Power over Ethernet Hub. The device will work with AC in the
range 100-240V AC, 50-60Hz.

Figure 2-3 Rear panel of the POH-0850TX
Connect the power cord to the power socket on the rear panel of the Switch. The other

side of power cord connects to the power outlet. The internal power supply of the
Switch works with voltage range of AC in the 100-240VAC, frequency 50~60Hz. Check
the power indicator on the front panel to see if power is properly supplied.
The Power over Ethernet Hub can provides power to the PD that follow the IEEE
802.3af standard in the network. It can solve the problem of position limitation. The
network device can be installed in more appropriate position for better performance.
The following figure is an example of network application for Power over Ethernet Hub.

switch or Wireless AP
Figure 2-3 Power over Ethernet Hub network application
Core Switch

Berfore you star to remote configuring PD, please intsall the software utility. Through
the software utility, you can easily to controll the PD that connect with PoE and view
the PD parameter informations. The software utility provides GUI interface and user
can easily to start with it. The software utility supports Windows environment -- Window
98, 2000, and XP. Please follow the below steps to install the software utility.

button to start installation. See Figure 3-2.
Figure 3-1



Figure 3-2 · Figure 3-3

“Remove/ Add application” Æ “Power Over Ethernet”.

Connecting the PoE with PC through the console port. Then, connect the PD (Powered
Device) to the port of PoE. Run the software utility and select the COM port form Serial
Link Setup function. You will see the main utility interface as figure 4-1.

Figure 4-1. The GUI management interface
The GUI management is divided into three parts:
system.
version.

device current configuration to the utility system and enable auto refresh function.
display.
Parametric Information: port parameters information display.
the port controlling.
PD device and enable this function to calibrate internal system.
PD Discovery R (ohms): set the PD resistor value range for the system detecting.
The default value range is 19000~26500. You can adjust the upper and lower limit
value when the system can’t detect the PD resistor in the default range. Please refer
to the “Discover R (ohms)” value in Parametric Information section to adjust the
upper and lower limit value. After you have adjusted the upper or lower limit value,
please unplug and then plug in the PD device.

Figure 4-2. System Setup & Control interface

Chip Version: display the system chipset version and revision information.
Firmware Version: display the system firmware version.
Total Port Power (W): total of all the port power that the system provided to PD.

Figure 4-3. System Information interface
Enable Auto-Refresh: It allows the system auto refresh the system parameters.
The system auto refresh in every 2 seconds.
system utility.
Port Specific Control, please press Save to Device button to apply the new
configuration into the system.


Figure 4-4 Device Setting interface

Enable” function.
to detect the 25kΩ resistor in an 802.3af compliant PD device. If the PD doesn’t
follow by IEEE 802.3af standard, you can enable this option to skip the detection
on PD. When you enable this function, the system will not perform the 25Ω
resistor detection for PD and directly transmit the power to PD. This function can
be cooperating with “PD discover R (ohms)” function in System setup & Control
section for non-standard compliant PD device.
[Note] after setting the Bypass Detection function, please unplug and then plug in
the PD device.
transmit the power to PD when this function is enabling. Normally the system will
try to classify the 802.3af compliant PD device by checking the current class level.
The following table is a standard current classification level table.
[Note] after setting the Bypass Classification function, please unplug and then plug
in the PD device.

Table of Power Device Classification Levels
LED Status Indicators: current LED indicator display – green, yellow, and red.

The LED indicator will change depends on the PD status.
normally.
¾ Yellow: It represents there is no PD connecting with the port.
cable is short.
and explain as following.
normal.
(475mA @ 48V DC) that the situation happens over 50msec.
Mode Status: display the PD current operation mode status.
¾ V sample or I sample: It means " Current sample or Voltage sample”.
When PD is detected and current is supplied, the POE hub will keep detecting
and sampling some current or voltage to ensure whether the PD still present
on this port. It is a IEEE 802.3af operating procedure.
each port and detects the resistor.

Figure 4-5. Port Specific Control interface

Discovery R (ohms): display resistance value.
Port Current (mA): display current value.
Port Voltage (V): display voltage value.
Port Power (W): display watt value.
classification” function, the class current value will not show in here. Please refer
to the following table for output value.
Maximum power of levels at
0 Default 15.4 Watts
1 Optional 4.0 Watts
2 Optional 7.0 Watts
3 Optional 15.4 Watts
4 Reserved for future use Treat as Class 0
classification” function, the class value will not show in here.

Figure 4-6. Parametric Information interface
Class Usage · output of PSE


Plug and play for standard PD and without any


Dimension 440mm x 224mm x 44mm (L x W x H)
EMI & safety FCC Class A, CE, UL, cUL

The female DB-9 serial port on the POE hub front panel is used to connect to the
switch for out-of-band console configuration. The web interface configuration program
can be accessed from PC running the system utility program. The pin assignments
used to connect to the serial port are provided in the following tables.

Figure 6-1. DB-9 Console Port Pin Numbers
DB-9 Port Pin Assignments

No other pins are used

Console Port to 9-Pin DTE Port on PC
CCITT Signal PC’s 9-Pin DTE Port
2 RXD < RXD 3 TxD
3 TXD TXD > 2 RxD
No other pins are used.
Switch’s 9-Pin Serial · Port